3
Flexible and efficient measurement The extension board PM-2 allows cost-effective measurement of relevant pow- er values in low and medium voltage systems. Various measured values such as frequency, power and phase displacement angle are directly available for the evaluation of the utilization of the equip- ment, the evaluation of the quality and stability of the voltage as well as the identification of anomalies in the distribution network. As an extension board for the net-line FW-5, the PM-2 is inserted into the I/O area of the RTU. setIT offers the specification of the measurement parameters and the selection of measured values from V6.000. The values are integrated directly in the process data from where they can be monitored, sent and recor- ded based on custom criteria. Typical application areas Local substations Decentralised power plants Systems with decentralised power distribution Industrial systems PM-2 Power measurement Brief profile PM-2 Power measurement module for recording relevant values in low and medium voltage systems. Measuring currents I 1 ,I 2 ,I 3 ,I N . Voltage measure- ment U 1 , U 2 , U 3 . Calculating I eff /U eff TRMS, U LL , P, Q, S, W, f, power factor, active and reactive power. Flexible selection of capacity from 12 single-point commands, 6 single- point information, 8 metered values and 47 measured values. Integration as an extension board in telecontrol systems of type FW-5/FW-5-GATE series5e. Internal power supply and commu- nication via system bus. Configu- ration as an I/O card in setIT from V6.000. Dimensions: 22.5x105x115 mm (WxHxD) PM-2 Power measurement

PM-2 Power measurement - Informationstechnologie

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Flexible and effi cient measurement

The extension board PM-2 allows cost-effective measurement of relevant pow-

er values in low and medium voltage systems.

Various measured values such as frequency, power and phase displacement

angle are directly available for the evaluation of the utilization of the equip-

ment, the evaluation of the quality and stability of the voltage as well as the

identifi cation of anomalies in the distribution network.

As an extension board for the net-line FW-5, the PM-2 is inserted into the I/O

area of the RTU. setIT offers the specifi cation of the measurement parameters

and the selection of measured values from V6.000. The values are integrated

directly in the process data from where they can be monitored, sent and recor-

ded based on custom criteria.

Typical application areas

• Local substations

• Decentralised power plants

• Systems with decentralised power distribution

• Industrial systems

PM-2Power measurement

Brief profi le PM-2

Power measurement module for

recording relevant values in low and

medium voltage systems. Measuring

currents I1,I2,I3,IN. Voltage measure-

ment U1, U2, U3. Calculating Ieff/Ueff

TRMS, ULL, P, Q, S, W, f, power factor,

active and reactive power.

Flexible selection of capacity from 12

single-point commands, 6 single-

point information, 8 metered values

and 47 measured values. Integration

as an extension board in telecontrol

systems of type FW-5/FW-5-GATE

series5e.

Internal power supply and commu-

nication via system bus. Confi gu-

ration as an I/O card in setIT from

V6.000.

Dimensions: 22.5x105x115 mm

(WxHxD)

PM-2 Power measurement

FW-5-GATE-4GDSO-1 (command operation)PM-2 (measure)

PM-1

L3L2L1

PM-1

monitoroperate

Control centre

LTE

LTE

monitor

operate

monitor

PM-2 Power measurement

© S

AE IT-system

s Gm

bH &

Co. KG S

ubject to tech

nical m

odification. Errors an

d omission

s excepted. Produ

ct images m

ay contain

special features. S

tatus:M

ai 2020

SAE IT-systems GmbH & Co. KG

Im Gewerbegebiet Pesch 14

50767 Köln (Cologne, Germany)

Phone.: +49(0)221/59808-0

Fax: +49(0)221/59808-60

[email protected]

www.sae-it.de

Design Power measurement module for telecontrol and substation automation in micro-housing, Polyamide V0, IP20, DIN top-hat rail assembly

Networks Measurement of medium voltages with CT, VT LV measurement with CT, voltage directly, 4-phase system, 3-phase system, one-phase

Current measurement PM-2 4 currents I1, I2, I3 IN: 0 … 1 A /5 A, resolution 1 mA, TRMS load 10 mΩ, overload max. 60 A (1 s), errors ±0.2%, sampling frequency 4 kHz

Voltage measurement PM-2

4 voltages U1, U2, U3: 0 … 690 V AC, ULL calculated, resolution 30 mV load 1130 kΩ, errors ±0.2%, sampling frequency 4 kHz

Network variables Frequency, 45 ... 66 Hz, resolution 0.001 Hz P, Q, S, error ±0.5% Energy W, Wb errors ±0.5%

Data range 47 measured values i.a. I, U, ULL, P, S, Q, W, Wb, f, PF 12 Single-point information: Faults, power load direction, rotary field errors 8 Counter values for power measurement 3 Single commands for acknowledgment

Measurement accuracy according to DIN EN 61557-12:2008

Status indicators LED in front plate for voltage, load, rotary fields and system status

Supply Internal via TBUS 100 mA @ TBUS

Dialectic strength 6 kV rated surge voltage, CAT III (600 V) CAT IV (300 V)

Standards EMC: DIN EN 61000-6-2:2006, DIN EN 61000-6-4:2011 Isolation: DIN EN 60870-2-1:1997

Housing Micro housing, Polyamide V0, IP 20, dimensions 22.5×105×115 mm (W×H×D) DIN top-hat rail, DIN-EN 60715 TH35 Screw terminal MSTB, 0.2 to 2.5 mm2

Ambient temperature -20° C... +70° C

Relative humidity < 95%, without condensation

Technical data: PM-2

PM-2 Power measurement