142
PRIMERGY TX300 S5 Options Guide Edition July 2009

PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

PRIMERGY TX300 S5 Options Guide

Edition July 2009

Page 2: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to email: [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and Trademarks

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

7-0

02.fm

Copyright © 2009 Fujitsu Technology Solutions GmbH.

All rights reserved.

Delivery subject to availability. The right to technical modification is reserved.

All hardware and software names used are trade names and/or trademarks of their respective manufacturers.

Page 3: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide

Contents

1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 7

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 8

1.3 Expansions and conversions . . . . . . . . . . . . . . . . . . 9

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 13

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 17

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

4.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 234.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 234.1.2 Removing the front cover . . . . . . . . . . . . . . . . . . . . 244.1.3 Removing the server feet . . . . . . . . . . . . . . . . . . . . 28

4.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 294.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 294.2.2 Removing the rack front cover . . . . . . . . . . . . . . . . . . 32

4.3 Removing the fan bracket . . . . . . . . . . . . . . . . . . . 33

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 35

5.1 Equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 355.1.1 Independent Channel Mode / Performance Mode . . . . . . . . 365.1.2 Mirrored Channel Mode . . . . . . . . . . . . . . . . . . . . . 375.1.3 Spare Channel Mode . . . . . . . . . . . . . . . . . . . . . . 38

5.2 Extending/replacing the main memory . . . . . . . . . . . . 39

Page 4: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

Options Guide TX300 S5

Contents

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

8-0

02.fm

6 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . . 41

6.1 Equipping of the bays . . . . . . . . . . . . . . . . . . . . . . 41

6.2 Accessible 5.25-inch drive . . . . . . . . . . . . . . . . . . . 436.2.1 Removing the dummy cover . . . . . . . . . . . . . . . . . . . 436.2.2 Installing an accessible 5.25-inch drive . . . . . . . . . . . . . . 45

6.3 Multibay 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476.3.1 Equipping Multibay 1 . . . . . . . . . . . . . . . . . . . . . . . 476.3.1.1 Installing LSP or LSD . . . . . . . . . . . . . . . . . . . . . 476.3.1.2 Installing a DVD drive . . . . . . . . . . . . . . . . . . . . . 506.3.2 Installing Multibay 1 . . . . . . . . . . . . . . . . . . . . . . . . 54

6.4 HDD extension box . . . . . . . . . . . . . . . . . . . . . . . 586.4.1 Multibay 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 596.4.1.1 Installing Multibay 2 . . . . . . . . . . . . . . . . . . . . . . 606.4.2 2.5-inch HDD extension box . . . . . . . . . . . . . . . . . . . 616.4.2.1 Installing 2.5 inch HDD extension box . . . . . . . . . . . . . 62

7 Expansion cards . . . . . . . . . . . . . . . . . . . . . . . . . 65

7.1 Installing an expansion card . . . . . . . . . . . . . . . . . . 66

8 Battery Backup Unit . . . . . . . . . . . . . . . . . . . . . . . 69

9 Trusted Platform Module (TPM) . . . . . . . . . . . . . . . . . 83

10 SAS/SATA RAID controller . . . . . . . . . . . . . . . . . . . 87

10.1 Inserting the RAID key . . . . . . . . . . . . . . . . . . . . . 87

11 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

11.1 Installing a second processor . . . . . . . . . . . . . . . . . 89

11.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 95

11.3 Replacing the heat sink . . . . . . . . . . . . . . . . . . . . 100

Page 5: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide

Contents

12 Conversion from a floorstand model to a rack model . . . . 101

12.1 Removing the right-hand side cover . . . . . . . . . . . . . 101

12.2 Removing the server feet . . . . . . . . . . . . . . . . . . . 102

12.3 Removing the foot mounting rail . . . . . . . . . . . . . . . 103

12.4 Accessible drives and operating panel module . . . . . . . 103

12.5 Installing the ID Card holder . . . . . . . . . . . . . . . . . . 10512.5.1 Server with 3.5-inch hard disk drives . . . . . . . . . . . . . . 10612.5.2 Server with 2.5-inch hard disk drives . . . . . . . . . . . . . . 114

12.6 Final steps . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

13 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

13.1 Installing the fan bracket . . . . . . . . . . . . . . . . . . . . 123

13.2 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 12513.2.1 Mounting the server feet . . . . . . . . . . . . . . . . . . . . . 12513.2.2 Attaching the front cover . . . . . . . . . . . . . . . . . . . . . 12613.2.3 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 128

13.3 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 13013.3.1 Attaching the rack front cover . . . . . . . . . . . . . . . . . . 13013.3.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 131

14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

14.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

Page 6: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

8-0

02.fm

Page 7: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 7

1 PrefaceWith top dual processor performance, the PRIMERGY TX300 S5 tower server is an all-purpose server for medium sized companies and branches of large enterprises. The system is ideal for use as a versatile business server for business critical applications and dedicated tasks. Thanks to internal SAS/SATA hard disk capacity of up to 6 or 8 TB, the PRIMERGY TX300 S5 is also suitable for use as a platform for highly data intensive solutions. Furthermore, it is the ideal solution for smaller mySAP installations and directory or cache services in medium sized and large companies.

The PRIMERGY TX300 S5 offers a balanced architecture that incorporates next generation main memory (DDR3) and I/O technologies (PCIe Gen2). The HDD backplane is already provided for SAS 2.0 and 6 Gbit/s SAS and the chipset prepared for the next generation of 6-core processors. High performance, scalability, impressive reliability and excellent extension options are combined in a powerful design.

The Cool-safe™ cooling concept with improved air flow cooling technology (comb design) ensures the highest possible performance of the processors at work; at the same time, the system is extremely reliable thanks to the reduced heat dissipation.

The new PRIMERGY TX300 S5 can also be converted quickly and easily into a space-saving rack system that only takes up 4 height units (HU).

1.1 Concept and target groups

This Options Guide shows you how to extend and upgrade your server.

V CAUTION!

The activities described in this manual may only be performed by technical specialists.

I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server.

Page 8: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

8 Options Guide TX300 S5

Documentation overview Preface

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

9-0

02.fm

1.2 Documentation overview

More information on your PRIMERGY TX300 S5 can be found in the following documents:

– "Quick Start Hardware - PRIMERGY TX300 S5" leaflet (only included as a printed copy)

– "Quick Start Software - Quick Installation Guide" DVD booklet (only included with the PRIMERGY ServerView Suite as a printed copy)

– "Safety notes and other important information" manual

– "Warranty" manual

– "PRIMERGY ServerView Suite Local Service Concept - LSC" manual

– "Returning used devices" manual

– "Helpdesk" leaflet

– Technical manual for the system board D2619

– "PRIMERGY TX300 S5 Server Operating Manual"

– "PRIMERGY TX300 S5 Server Options Guide"

– "D2619 BIOS Setup Utility for PRIMERGY RX300 S5 and TX300 S5" manual

I PRIMERGY manuals are available in PDF format on the PRIMERGY ServerView Suite DVD 2. The PRIMERGY ServerView Suite DVD 2 is part of the PRIMERGY ServerView Suite supplied with every server.

If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289.

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL: http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

Page 9: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 9

Preface Expansions and conversions

Further sources of information:

– PRIMERGY Abbreviations and Glossary on the PRIMERGY ServerView Suite DVD 2

– Manual for the monitor– Documentation for the boards and drives– Operating system documentation– Information files in your operating system

1.3 Expansions and conversions

Customer Self Service (CSS)

The Fujitsu Technology Solutions Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.

In the CSS concept, you can replace the following components yourself in the event of an error:

– Hot-plug hard disk drives

– Hot-plug power supply units

– Memory modules

– Hot-plug system fan

– Expansion cards

CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises (for more information on the behavior of these indicators, see the operating manual and the "PRIMERGY ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY ServerView Suite DVD 2).

You can also fit your server with a ServerView Local Service Panel, which enables you to identify the type of component affected by the error directly on the server (for more information, see the "PRIMERGY ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY ServerView Suite DVD 2).

In addition, CSS errors are displayed in the ServerView Operations Manager - the server management software from Fujitsu Technology Solutions.

Page 10: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

10 Options Guide TX300 S5

Expansions and conversions Preface

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

9-0

02.fm

In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question.

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system.

Main memory expansion

The system board has 18 slots for memory modules. 9 memory slots can be used in mono processor configurations.

ECC with memory scrubbing and the Single Device Data Correction (SDDC) function is standard.

There are three modes of operation for the main memory:

– Independent Channel Mode / Performance Mode (recommended)– Mirrored Channel Mode– Spare Channel Mode

Depending on the mode of operation there are different population requirements.

Page 11: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 11

Preface Expansions and conversions

Trusted Platform Module (TPM)

A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption).

The TPM is activated via the BIOS system (for more information, refer to the Fujitsu Technology Solutions BIOS manual).

V CAUTION!

– When using the TPM, note the program descriptions provided by the third party manufacturers.

– You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data.

– If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content.

Additional accessible drives

The server has three 3.5-inch bays.

You can use these bays as follows:

– You can equip the individual bays with DVD drives or magnetic tape drives.

– You can install the Multibay 1 in the bottom bay. The Multibay 1 has bays for a Slimline DVD drive and the ServerView Local Service Panel (LSP) or the ServerView Local Service Display (LSD).

– In the two lower bays, you can install the Multibay 2. The Multibay 2 has bays for two additional 3.5-inch hard disk drives, a Slimline DVD drive and the ServerView Local Service Panel (LSP) or the ServerView Local Service Display (LSD).

– You can install the Multibay 1 in the bottom bay (see above) and the expansion box for 2.5-inch SAS hard disk drives in the two upper bays.

Page 12: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

12 Options Guide TX300 S5

Expansions and conversions Preface

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

9-0

02.fm

Additional expansion cards in the PCI Express slots

The system board has seven PCI Express slots. Slots 1-5 are connected as x4 interfaces, whereby slots 3 and 5 are used as x8 interfaces if slots 2 and 4 are empty. Slots 6 and 7 are connected as x8 interfaces.

I Slot 1 is the preferred slot for the SAS/SATA RAID controller (bootable).

Slots 5 and 7 allow the mechanical installation of x16 PCIe expansion cards. The bus width is restricted to 8 lanes.

RAID key

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key) on the SAS/SATA controller.

Battery Backup Unit

A Battery Backup Unit (BBU) backs up the memory contents of the SAS/SATA RAID controller in the event of a power failure. One BBU can be installed for each SAS/SATA RAID controller. A maximum of three BBUs can be installed for each system.

Conversion from a floorstand model to a rack model

The floorstand model can be converted into a space-saving rack system that only takes up 4 height units (HU). The server can thus be installed in any typical rack systems.

ServerView Local Service Panel or Display

The system board supports the CSS (Customer Self Service) functionality (see the operating manual and the "PRIMERGY ServerView Suite Local Service Concept - LSC" manual). You can install a ServerView Local Service Panel (LSP) or a ServerView Local Service Display (LSD) for an easier identification of the defective components.

Page 13: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 13

Preface Notational conventions

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

"Quotation marks" indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 14: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-432

9-0

02.fm

Page 15: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 15

2 ProcedureV CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

I Procedures which are identical for the floorstand and rack models are only described for the floorstand model.

Ê First of all, carefully read the safety instructions in the "Safety instructions" on page 17.

Ê Make sure that all necessary manuals (see the section "Documentation overview" on page 8) are available; print the PDF files if required. Most importantly, you will need the operating manual for the server and the technical manual for the system board.

Ê Shut the server down correctly, switch it off, disconnect the power plugs and open the server as described in the chapter "Preparation" on page 23.

Ê Carry out the expansion or upgrade of your server as described in the pertinent chapter.

I Installation and removal of the hot-plug components are described in the operating manual.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 123.

Ê Start the operating system and make the appropriate configuration if necessary (see the operating manual).

Page 16: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

0-0

02.fm

Page 17: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 17

3 Safety instructionsI The following safety instructions are also provided in the manual "Safety

notes and other important information".

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Page 18: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

18 Options Guide TX300 S5

Safety instructions

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

1-0

02.fm

Before starting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● This unit should not be operated in ambient temperatures above 35 °C.

● If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors.

● The unit automatically adjusts itself to a mains voltage in a range of 100 V - 240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded shock-proof sockets or insulated sockets of the rack's internal power supply with tested and approved power cables.

● Ensure that the device is connected to a grounded shockproof socket close to the device.

Page 19: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 19

Safety instructions

V CAUTION!

● Ensure that the power sockets on the device and the grounded shockproof sockets are freely accessible.

● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded shockproof sockets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded.

● The EN 50173 and EN 50174-1/2 standards apply for LAN cabling. The minimum requirement is the use of a category 5 screened LAN cable for 10/100 Mbit/s Ethernet, or a category 5e cable for Gigabit Ethernet. The requirements from the ISO/IEC 11801 specification must also be met.

● Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual.

● Never connect or disconnect data transmission lines during a storm (risk of lightning strike).

● Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team.

Page 20: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

20 Options Guide TX300 S5

Safety instructions

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

1-0

02.fm

V CAUTION!

● Proper operation of the system (in accordance with IEC 60950-1/ EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet.

● The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CCS components can be replaced.

● The warranty is void if the server is damaged during installation or replacement of system expansions.

● Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.

Batteries

V CAUTION!

● Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board).

● Replace the lithium-battery on the system board in accordance with the instructions in the technical manual for the system board.

Page 21: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 21

Safety instructions

Working with CDs/DVDs and CD/DVD drives

When working with devices with CD/DVD drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance.

Damaged and imbalanced CDs/DVDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD fragments can pierce the cover of the CD/DVD drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

I You can prevent mechanical damage and damage to the CD/DVD drive, as well as premature CD/DVD wear, by observing the following suggestions:

– Only insert CDs/DVDs in the drive when needed and remove them after use.

– Store the CDs/DVDs in suitable sleeves.– Protect the CDs/DVDs from exposure to heat and direct sunlight.

Laser information

The CD/DVD drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The CD/DVD drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the CD/DVD drive casing!

Page 22: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

22 Options Guide TX300 S5

Safety instructions

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

1-0

02.fm

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 23: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 23

4 PreparationV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

4.1 Floorstand model

I For some expansions and conversions, it is advisable to lay the server on its right-hand side and remove the server feet.

4.1.1 Opening the server

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the on/off button.

Ê Pull all power connectors out of the power outlets.

Ê If required, remove the lock on the side cover.

Page 24: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

24 Options Guide TX300 S5

Floorstand model Preparation

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

2-0

02.fm

Ê If necessary, lay the server on its right-hand side.

Get a second person to help you do this. The server can weigh around 25 -40 kg (depending on the configuration).

Make sure that the server feet protrude over the table edge.

Figure 2: Removing the side cover

Ê Pull the locking lever as far as it will go (1).

This pushes the side cover backward (2).

Ê Remove the side cover (3).

4.1.2 Removing the front cover

Remove the front cover when making the following extensions and upgrades:

– Installation of further accessible drives

– Conversion from a floorstand model to a rack model

3

1 2

Page 25: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 25

Preparation Floorstand model

Figure 3: Removing the drive cover and the hard disk cover

Ê Unlock the server and remove the key.

Ê Remove the drive cover (1).

Ê Remove the hard disk cover (2).

1

2

Page 26: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

26 Options Guide TX300 S5

Floorstand model Preparation

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

2-0

02.fm

Figure 4: Pulling out the locking buttons

Ê Pull out the two green locking buttons (1).

11

Page 27: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 27

Preparation Floorstand model

Figure 5: Removing the front cover

Ê Pull the front cover forward slightly at the lower edge.

Ê Unhook the front cover at the top and remove it.

Page 28: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

28 Options Guide TX300 S5

Floorstand model Preparation

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

2-0

02.fm

4.1.3 Removing the server feet

Figure 6: Removing the server feet

Ê If necessary, remove the server feet.

To do this, you need to loosen four screws on each of the feet (see circles).

Page 29: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 29

Preparation Rack model

4.2 Rack model

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the on/off button.

Ê Pull all power connectors out of the power outlets.

4.2.1 Opening the server

Figure 7: Loosening the knurled screws and pulling the server out of the rack

Ê Loosen the two knurled screws (1) and pull the server as far as possible out of the rack (2).

2

1

Page 30: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

30 Options Guide TX300 S5

Rack model Preparation

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

2-0

02.fm

Depending on how accessible the server is in the rack cabinet, it can make sense to remove the server from the rack cabinet: If you do not want to remove the server from the rack cabinet, please skip this page.

Figure 8: Removing the server from the rack cabinet

Ê Disconnect all cables on the rear side of the server.

Ê Remove one screw on each side (1).

Ê Slide the server a little way in the direction of the arrow (2) until the hooks (a) on the telescopic rails are released.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

Never lift or carry the server by the handles on the front panel.

Ê Lift the server out of the rails (3) and place it on a table, for example.

1

1

a

2

3

Page 31: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 31

Preparation Rack model

Figure 9: Opening and removing the housing cover

Ê Pull the locking lever as far as it will go (1).

This pushes the housing cover backward (2).

Ê Remove the housing cover (3).

312

Page 32: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

32 Options Guide TX300 S5

Rack model Preparation

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

2-0

02.fm

4.2.2 Removing the rack front cover

Remove the rack front cover when carrying out the following expansion:

– Installation of further accessible drives

Figure 10: Removing the rack front cover

Ê Remove two knurled screws on either side (1).

Ê Remove the rack front cover to the front together with the plastic cover (2).

1

1

2

Page 33: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 33

Preparation Removing the fan bracket

4.3 Removing the fan bracket

Figure 11: Removing the fan bracket: disconnecting the power cable, loosening the knurled screws

Ê Disconnect the 10-pole plug of the power cable T26139-Y3952-V401 from the fan backplane (1).

Ê Release the cable clip and take out the cable (2).

Ê Loosen the two knurled screws of the fan bracket (3).

1 1

2

2

3

3

Page 34: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

34 Options Guide TX300 S5

Removing the fan bracket Preparation

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

2-0

02.fm

Figure 12: Removing the fan bracket: taking the fan bracket out of the server

Ê Push the fan bracket in the direction of the arrow (1).

Ê Take the fan bracket out of the server (2).

V CAUTION!

Ensure that you do not damage the SAS cables when sliding the fan bracket in or lifting it out.

1

1

2

Page 35: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 35

5 Main memoryV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

The system board has 18 slots for memory modules.

9 memory slots can be used in mono processor configurations.

ECC with memory scrubbing and the Single Device Data Correction (SDDC) function are activated by default.

5.1 Equipping rules

● The system must be equipped with at least one memory module.

● Memory modules supported:DDR3-800 PC3-6400, DDR3-1066 PC3-8500 or DDR3-1333 PC3-10500Registered FB-DIMMs with ECC

● Permitted module sizes: 2 GB, 4 GB or 8 GB.Maximum memory configuration: 144 GB (with Nehalem-EP Processor)

● The first memory slot that has to be equipped is slot 1 / channel A

(DIMM 1A).If all channels are to be equipped, equip slot 1 before slot 2, and slot 2 before slot 3.

● There are three modes of operation for the main memory:

– Independent Channel Mode / Performance Mode (recommended)– Mirrored Channel Mode– Spare Channel Mode

Depending on the mode of operation there are different population requirements.

Page 36: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

36 Options Guide TX300 S5

Equipping rules Main memory

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

3-0

02.fm

5.1.1 Independent Channel Mode / Performance Mode

Figure 13: Independent Channel Mode / Performance Mode

● Independent Channel Mode allows the memory channels to be equipped in any order independently of each other.

● All channels run at the fastest possible common clock rate of the installed memory modules. If memory modules with different speeds are used, the memory system is forced to run at the speed of the slowest memory module.

● Minimum memory configuration is one memory module: DIMM 1A.

Page 37: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 37

Main memory Equipping rules

● In the interest of system performance, the first slot of a channel should always be populated first, then the second, and finally the third.

I Identical memory modules (capacity and speed) must be used across all channels for Performance Mode.

Example: 1A-1B-1C

5.1.2 Mirrored Channel Mode

Figure 14: Mirrored Channel Mode

● Channels A and B must be identical in Mirrored Mode.

● Both channels must be equipped with memory modules that are organized identically (#ranks, #rows, #cols, #banks).

Page 38: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

38 Options Guide TX300 S5

Equipping rules Main memory

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

3-0

02.fm

● All channels run at the fastest possible common clock rate of the installed memory modules. If memory modules with different speeds are used, the memory system is forced to run at the speed of the slowest memory module.

● Channel C cannot be used in this configuration. Only one-third of the maximum memory configuration can be used in this mode.

5.1.3 Spare Channel Mode

Figure 15: Spare Channel Mode

● Channel C is the reserve (spare) channel for the two active channels A and B.

● All three channels must be equipped identically.

Page 39: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 39

Main memory Extending/replacing the main memory

● The channels must be equipped with memory modules that are organized identically (#ranks, #rows, #cols, #banks).

● Channel C is the only possible spare channel.

● The memory slots within a channel do not need to be equipped identically.

● The corresponding memory slots of all three channels must be equipped identically (example: 1A-1B-1C).

5.2 Extending/replacing the main memory

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the fan bracket (see section "Removing the fan bracket" on page 33).

Figure 16: Removing a memory module

Ê Press the holders on either side of the mounting location concerned outward (1).

Ê If the slot was equipped: pull the memory module out of the slot (2).

Page 40: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

40 Options Guide TX300 S5

Extending/replacing the main memory Main memory

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

3-0

02.fm

Figure 17: Inserting a memory module

Ê Carefully press the new memory module into the slot (1) until the fastening tabs on both sides of it engage (2).

Ê Reinstall the fan bracket (see section "Installing the fan bracket" on page 123).

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

Page 41: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 41

6 Accessible drivesV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

6.1 Equipping of the bays

Three 5.25-inch bays are available for accessible drives. You can install DVD drives, magnetic tape drives, a multibay (DVD drive and ServerView LSP or LSD), or an HDD extension box in these bays.

Figure 18: Bays for accessible drives

Bay 1 5.25" x 1.6" 5.25" x 1.6"

5.25" x 1.6"

3.5" ServerView LSD or LSP

5.25" slimline DVD drive

5.25" x 1.6"

5.25" x 1. 6"

Bay 2 or

Bay 3

Page 42: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

42 Options Guide TX300 S5

Equipping of the bays Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

Recommended equipping of the bays:

Order Installed accessible drive

Bay Max. number

Bays occupied Interface

1. Multibay with DVD drive

3 bottom 1 1 x 0.5" x 5.25" SAS

1. Multibay with LSD or LSP

3 bottom 1 1 x 0.5" x 5.25 I²C bus

1. DVD drive 3 (if 2 occupied)

1 1 x 1.6" x 5.25 SATA

2. LTO2 HH Ultrium 1 1 1 x 1.6" x 5.25 SCSI

2. LTO3 HH Ultrium 1 (if 2 occupied)

1 1 x 1.6" x 5.25 SCSI

2. LTO4 HH Ultrium 1 (if 2 occupied)

1 1 x 1.6" x 5.25 SAS

2. DDS Gen 6 1 (if 2 occupied)

1 1 x 1.6" x 5.25 SCSI

3. DDS Gen 6/

DDS Gen 5

1 (if 2 occupied)

2 1 x 1.6" x 5.25 USB 2.0

4. RDX drive 1 (if 2 occupied)

1 1 x 1.6" x 5.25 USB 2.0

5. 2.5" SAS HDD box 1 + 2 (if 2 + 3 occupied)

1 1 x 3.2" x 5.25 SAS

5. 3.5" SAS HDD box 2 + 3 (if 1 + 2 occupied)

1 1 x 3.2" x 5.25 SAS

Page 43: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 43

Accessible drives Accessible 5.25-inch drive

6.2 Accessible 5.25-inch drive

Ê Open the server (see chapter "Preparation" on page 23).

I New 5.25-inch drives are supplied without EasyClick rails. Before installing a new drive you must therefore remove the EasyClick rails from the dummy cover and mount the EasyClick rails on the new drive.

6.2.1 Removing the dummy cover

Figure 19: Removing the dummy cover

Ê Press inward on the two metal tongues of the EasyClick rails (1) until the locking mechanism disengages.

Ê Remove the dummy cover from the mounting bay (2).

1

1 2

Page 44: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

44 Options Guide TX300 S5

Accessible 5.25-inch drive Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

Figure 20: Detaching the EasyClick rails from the dummy cover

Ê Detach the EasyClick rails from the dummy cover by removing the four screws on each side (see arrows).

I Note that there are two M3 x 4,5mm screws with M3 thread (yellow ellipse) and two 6-32 x 4,8mm screws with UNC thread (blue ellipse) on each side.

V CAUTION!

Keep the dummy cover for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 45: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 45

Accessible drives Accessible 5.25-inch drive

6.2.2 Installing an accessible 5.25-inch drive

Figure 21: Attaching the EasyClick rails (example: DVD drive)

Ê Screw the EasyClick rails onto either side using two M3 x 4.5 mm screws.

Use the first hole in each upper row of holes as shown in the figure.

I Keep the remaining screws for future use. The different drives are fastened using different screws.

Page 46: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

46 Options Guide TX300 S5

Accessible 5.25-inch drive Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

V CAUTION!

If screws are too long, they may damage the drive.

Ê Push the new drive about halfway into the bay.

Ê Connect the data cable to the accessible drive (see the cabling plans in the Appendix).

Ê Connect the power cable to the accessible drive (see the cabling plans in the Appendix).

Ê Push the drive fully into the bay until the EasyClick rails lock in place.

Ê Attach the front cover or rack front cover and close the server (see chapter "Completion" on page 123).

Accessible drive Required screws

LTO2 HH Ultrium M3 x 3,5 mm *

LTO3 HH Ultrium M3 x 3,5 mm *

LTO4 HH Ultrium M3 x 4,5 mm

DDS Gen 5 M3 x 4,5 mm

DDS Gen 6 (USB / SCSI) M3 x 4,5 mm

RDX drive M3 x 4,5 mm

* These screws are included in the delivery of the drive.

Page 47: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 47

Accessible drives Multibay 1

6.3 Multibay 1

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the dummy cover from the mounting bay 3 (see section "Equipping of the bays" on page 41 and section "Removing the dummy cover" on page 43).

Ê Detach the EasyClick rails from the dummy cover by removing the four screws on each side (see figure 20 on page 44).

I Note that there are two M3 x 4,5mm screws with M3 thread and two 6-32 x 4,8mm screws with UNC thread on each side.

6.3.1 Equipping Multibay 1

Multibay 1 can be equipped with a ServerView Local Service Panel (LSP) or a ServerView Local Service Display (LSD) and a DVD drive.

6.3.1.1 Installing LSP or LSD

Figure 22: ServerView Local Service Display (LSD) and ServerView Local Service Panel (LSP)

Page 48: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

48 Options Guide TX300 S5

Multibay 1 Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

Figure 23: Sliding the LSP in the 3.5-inch frame

Ê From the front, slide the LSP/LSD module into the 3.5-inch frame (see locking latch in circle).

Page 49: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 49

Accessible drives Multibay 1

Figure 24: Sliding the 3.5-inch frame with LSP in Multibay 1

Ê Slide the 3.5-inch frame with the LSP/LSD from the rear side in Multibay 1.

Figure 25: Fastening the 3.5-inch frame with LSP in Multibay 1

Ê Fasten the 3.5-inch frame using two M3 x 6 mm screws on either side.

Page 50: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

50 Options Guide TX300 S5

Multibay 1 Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

6.3.1.2 Installing a DVD drive

Figure 26: Inserting a DVD drive in the frame

Ê Insert the DVD drive in the frame.

The four pins on the frame (see circles) engage with the screw holes on the drive and lock it in place.

Page 51: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 51

Accessible drives Multibay 1

Figure 27: Connecting the PS adapter cable to the DVD drive

Ê Connect the PS adapter cable at the rear of the DVD drive (see the cabling plans in the Appendix).

Page 52: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

52 Options Guide TX300 S5

Multibay 1 Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

Figure 28: Inserting the DVD drive module in the multibay module

Ê From the front, insert the DVD drive module into Multibay 1 until it engages (see locking latch in circle).

Page 53: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 53

Accessible drives Multibay 1

Figure 29: Attaching EasyClick rails to Multibay 1

Ê Screw the EasyClick rails onto either side using two M3 x 4.5 mm screws.

Use the first hole in each lower row of holes as shown in the figure.

Page 54: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

54 Options Guide TX300 S5

Multibay 1 Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

6.3.2 Installing Multibay 1

Figure 30: Connecting the SATA cable to the DVD drive

Ê Pull the SATA cable (1) out of the housing through the drive cage.

Ê Connect the SATA cable at the rear of the DVD drive (see the cabling plans in the Appendix).

1

2

Page 55: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 55

Accessible drives Multibay 1

Figure 31: Installing Multibay 1

Ê Push Multibay 1 fully into bay 3 until the EasyClick rails lock in place.

Ensure that no damage is caused to the cables.

Page 56: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

56 Options Guide TX300 S5

Multibay 1 Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

Figure 32: Connecting the PS adapter cable to the power cable

Ê Connect the PS adapter cable to the CON.2 or CON.4 or CON.6 connector of the power cable (see the cabling plans in the Appendix).

Figure 33: Routing the power cable

Ê Route the power cable using the cable clips as shown.

Page 57: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 57

Accessible drives Multibay 1

Figure 34: Connecting the I²C bus cable to the LSP/LSD

Ê Remove the cable tie of the I²C bus cable near the CON.4 connector.

Ê Connect the I²C bus cable CON.4 connector to the LSP/LSD (see the cabling plans in the Appendix).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 123.

Page 58: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

58 Options Guide TX300 S5

HDD extension box Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

6.4 HDD extension box

In the base units two 5.25-inch bays for accessible drives can be used to install a HDD extension box.

Two variants of the HDD extension box are available:

● HDD extension box for 3.5-inch HDD modules (Multibay 2):

Multibay 2 contains one bay for a LSP or LSD, one bay for a DVD drive, and two bays for 3.5-inch HDD modules.

● HDD extension box for 2.5-inch HDD modules:

This HDD extension box contains eight bays for 2.5-inch HDD modules.

The HDD extension box is supplied without EasyClick rails. You need 4 M3 screws. Before installing a new HDD extension box you must therefore remove the EasyClick rails from one dummy cover and mount two EasyClick rails on the HDD extension box.

Ê Remove the dummy covers from the required 5.25-inch bays (see section "Equipping of the bays" on page 41 and section "Removing the dummy cover" on page 43).

Ê Detach the EasyClick rails from a dummy cover by removing the four screws on each side (see figure 19 on page 43).

I Note that there are two M3 screws and two UNC screws on each side figure 20 on page 44.

V CAUTION!

Keep the dummy covers for future use. If you remove the HDD extension box again and do not replace it with a new one, the dummy covers must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 59: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 59

Accessible drives HDD extension box

6.4.1 Multibay 2

Multibay 2 contains one bay for a LSP or LSD, one bay for a DVD drive, and two bays for 3.5-inch HDD modules.

Figure 35: Attaching EasyClick rails to Multibay 2

Ê Screw the EasyClick rails onto either side using two M3 x 4.5 mm screws (1).

Ê Install a DVD drive, if required.

The procedure is similar to that of Multibay 1 (see section "Installing a DVD drive" on page 50).

Ê Install a LSP or LSD, if required.

The procedure is similar to that of Multibay 1 (see section "Installing LSP or LSD" on page 47).

I Note that in this case the LSP/LSD module is inserted in Multibay 2 from the front.

Page 60: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

60 Options Guide TX300 S5

HDD extension box Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

6.4.1.1 Installing Multibay 2

When installing Multibay 2, proceed in a similar way as for installing Multibay 1. See section "Installing Multibay 1" on page 54 on how to connect the SATA cable to the DVD drive and connect the PSU adapter cable to the power cable.

Ê Push Multibay 2 fully into bays 2 and 3 until the EasyClick rails lock in place.

Ensure that no damage is caused to the cables.

Figure 36: Cabling Multibay 2

Ê Connect the HDD backplane of Multibay 2 (yellow circle: X1 connector) and the HDD backplane from the system (blue circle: MLC3 connector) to the SAS cable included.

Ê Connect the CON.6 connector of the power cable to the HDD backplane of Multibay 2 (X5 connector).

Ê Remove the cable strap located near connector CON.4 from the I2C bus cable.

Ê Connect the I2C bus cable connector CON.4 to the LSP/LSD module (see cabling plans in the appendix)

Ê Connect the I²C cable to the HDD backplane of Multibay 2 (X7 connector).

Page 61: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 61

Accessible drives HDD extension box

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in chapter "Completion" on page 123.

6.4.2 2.5-inch HDD extension box

The HDD extension box for 2.5-inch HDD modules contains eight bays for 2.5-inch HDD modules. It requires a redundant power supply (see operating manual) and an additional SAS/SATA RAID controller (see chapter "Expansion cards" on page 65).

Figure 37: Attaching EasyClick rails to 2.5-inch HDD extension box

Ê Screw the EasyClick rails onto either side using two M3 x 3.5 mm screws.

V CAUTION!

Longer M3 screws may damage the drive!

The M3 x 4.5 mm screws of a dummy cover are too long and must not be used.

Page 62: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

62 Options Guide TX300 S5

HDD extension box Accessible drives

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

6.4.2.1 Installing 2.5 inch HDD extension box

Figure 38: Connecting PS adapter cable to HDD backplanes

Ê Connect the PS adapter cable to the two HDD backplanes at the rear of the HDD extension box (X6 connectors).

Ê Push the HDD extension box fully into bays 1 and 2 until the EasyClick rails lock in place.

Ensure that no damage is caused to the cables.

Page 63: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 63

Accessible drives HDD extension box

Figure 39: Cabling 2.5-inch HDD extension box

Ê Connect the PS adapter cable to the CON.2 and CON.4 connections of the power cable.

Ê Connect the SAS cables included in the conversion kit to the SAS connectors on the HDD backplanes (see circle).

Observe the label on the plug (X1 right or X1 left).

Ê Route the SAS cables through the cable brackets and connect them to the connectors of an additional SAS/SATA RAID controller (see the cablingplans in the appendix).

Ê Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 123.

Page 64: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

4-0

02.fm

Page 65: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 65

7 Expansion cardsV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

The system board has seven PCI Express slots. Slots 1-5 are connected as x4 interfaces, whereby slots 3 and 5 are used as x8 interfaces if slots 2 and 4 are empty.

I Slot 1 is the preferred slot for the SAS/SATA RAID controller (bootable).

Figure 40: Arrangement of the PCIe slots

Slot Description

1 PCIe x4 for SAS/SATA RAID controller

2 PCIe x4

3 PCIe x4 (PCIe x8, if slot 2 is free)

4 PCIe x4

5 PCIe x4 (PCIe x8, if slot 4 is free)

6 PCIe x8

7 PCIe x8

Page 66: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

66 Options Guide TX300 S5

Installing an expansion card Expansion cards

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

5-0

02.fm

I For more information see the Technical Manual of the system board D2619.

7.1 Installing an expansion card

Ê Open the server (see chapter "Preparation" on page 23).

Figure 41: Removing the slot cover

Ê Open the slot locking bar in the direction of the arrow (1).

Ê Remove the slot locking bar.

Ê Remove the slot cover (2).

V CAUTION!

Keep the slot cover in a safe place. If you remove the expansion card again and do not replace it with a new one, then reinstall the slot cover to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

1

2

Page 67: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 67

Expansion cards Installing an expansion card

Figure 42: Installing an expansion card

Ê Carefully press the new expansion card into the relevant slot on the system board (1) until it clicks into place.

Ê Fit the clip onto the slot cover so that the pin fits into the hole.

Ê Push the clip under the metal nose (2) until it clicks into place.

Ê Swing the lever (3) downwards into its locking position.

Ê If necessary, connect the cable to the expansion card and the other components.

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

1

3 2

Page 68: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

5-0

02.fm

Page 69: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 69

8 Battery Backup UnitV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

The Battery Backup Unit (BBU) backs up the memory contents of the SAS/SATA RAID controller in the event of a power failure.

One BBU can be installed for each SAS/SATA RAID controller. A maximum of three BBUs can be installed for each system.

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the fan bracket (see section "Removing the fan bracket" on page 33).

Figure 43: Removing the BBU carrier plate

Ê Loosen the screw and remove the BBU carrier plate from the housing.

Page 70: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

70 Options Guide TX300 S5

Battery Backup Unit

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

The BBU carrier plate can accommodate up to three BBUs.

Figure 44: Position of the screws on the BBU carrier plate

Blue circles: screwing position for BBU 1Yellow circles: screwing position for BBU 2Green circles: screwing position for BBU 3

Page 71: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 71

Battery Backup Unit

Figure 45: Fastening BBUs onto the BBU carrier plate

Ê Fasten each BBU onto the BBU carrier plate in the specified order using the three screws included in the BBU kit.

1

32

Page 72: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

72 Options Guide TX300 S5

Battery Backup Unit

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

Figure 46: Connecting the cable to the BBU

Ê Connect the BBU cables to the BBUs.

V CAUTION!

Make sure that connector side A (one pin row) is facing the BBU.

If connector side B (two pin rows) is facing the BBU, you risk short-circuits.

BA

Page 73: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 73

Battery Backup Unit

Figure 47: Mounting the BBU carrier plate

Ê Mount the carrier plate in the recesses of the drive cage (see circles).

Page 74: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

74 Options Guide TX300 S5

Battery Backup Unit

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

Figure 48: Fastening the BBU carrier plate

Ê Close the carrier plate at the top onto the drive cage.

Ê Screw the BBU carrier plate to the drive cage again, using the M3 x 6 mm screw (see circle).

Page 75: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 75

Battery Backup Unit

Figure 49: Opening the cable cover

Ê Loosen the knurled screw on the cable cover (1) and slide the cable cover (2) until the guide releases (see circle).

2

1

Page 76: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

76 Options Guide TX300 S5

Battery Backup Unit

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

Figure 50: Removing the cable cover

Ê Open the cable cover and pull it out of the guide (see circles).

Page 77: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 77

Battery Backup Unit

Figure 51: Routing the first and second BBU cable

Ê Route the first and second BBU cable through the cable guide as shown (1 + 2).

Ê Connect the cable to the expansion card (3).

2 3

1

Page 78: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

78 Options Guide TX300 S5

Battery Backup Unit

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

Figure 52: Removing the voltage converter holder

To route the third BBU cable, the voltage converter holder is removed:

Ê Remove the two screws (see circles).

Ê Slide the voltage converter holder in the direction of the arrow and remove it.

Page 79: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 79

Battery Backup Unit

Figure 53: Threading the third BBU cable through the cable opening

Ê Thread the third BBU cable through the cable opening in the voltage converter holder (see circle).

Ê Route the third BBU cable between the secondary processor socket and the memory slots related to PCI Express slot 6 or slot 7.

Page 80: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

80 Options Guide TX300 S5

Battery Backup Unit

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

Figure 54: Reinstalling the voltage converter holder

Ê Reinsert the voltage converter holder in the housing and lock it in place in the direction of the arrow.

Make sure that the two guides (see circles) on the board engage in the loops on the housing bottom.

Ê Secure the voltage converter holder with the two screws.

Page 81: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 81

Battery Backup Unit

Figure 55: Mounting and fastening the cable cover

Ê Mount the cable cover in the recesses.

Ê Close the cable cover at the top.

Ê Make sure that the third guide engages in the recess of the cable guide (see circle).

Ê Secure the cable cover with the knurled screw.

Ê Reinstall the fan bracket (see section "Installing the fan bracket" on page 123).

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

Page 82: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

6-0

02.fm

Page 83: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 83

9 Trusted Platform Module (TPM)

Contents of the TPM installation kit

Figure 56: Contents of the TPM installation kit

Installing a TPM module

V CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

Ê Open the server (see chapter "Preparation" on page 23).

Ê Pull the hot-plug power supply unit from its slot (see operating instructions).

1 TPM module 3 Special screw for TPM

2 TPM spacer 4 TPM screwdriver insert bit for

TPM special screw

1 2 3 4

Page 84: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

84 Options Guide TX300 S5

Trusted Platform Module (TPM)

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

7-0

02.fm

Figure 57: Inserting the TPM spacer on the system board

Ê Insert the TPM spacer into the hole on the system board.

Page 85: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 85

Trusted Platform Module (TPM)

Figure 58: Securing the TPM module

Ê Place the TPM module onto the system board (1).

Ê Secure the TPM module with the special screw for the TPM (2).

Please use the TPM screwdriver insert bit to tighten the special screw.

I Do not fasten the screw too tightly.

Ê Install the hot-plug power supply unit in its slot again (see operating instructions).

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

1

2

Page 86: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

7-0

02.fm

Page 87: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 87

10 SAS/SATA RAID controllerV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

10.1 Inserting the RAID key

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the fan bracket (see section "Removing the fan bracket" on page 33).

Ê Remove the SAS/SATA RAID controller (see operating instructions).

Figure 59: Inserting the RAID key

Ê Insert the RAID key in the round socket on the SAS/SATA RAID controller.

Page 88: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

88 Options Guide TX300 S5

Inserting the RAID key SAS/SATA RAID controller

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

8-0

02.fm

Ê Install the SAS/SATA RAID controller, see section "Installing an expansion card" on page 66.

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

Page 89: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 89

11 ProcessorsV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

V CAUTION!

Processors are modules which can react extremely sensitively to electrostatic discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never push a processor over a surface.

11.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor and a heat sink.

V CAUTION!

Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system.

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the fan bracket (see section "Removing the fan bracket" on page 33).

Page 90: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

90 Options Guide TX300 S5

Installing a second processor Processors

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

9-0

02.fm

Figure 60: Opening the heat sink retaining clips

Ê Press the heat sink retaining clips downward and inward to release them.

Ê Fold the heat sink retaining clips back.

Page 91: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 91

Processors Installing a second processor

Figure 61: Opening the processor holder and removing the socket cover

Ê Press the spring clip downward and outward.

Ê Fold back the spring clip (1).

Ê Fold back the processor holder (2).

Ê Hold the socket cover by the two grips between your thumb and index finger and lift it vertically upward (3).

1

2

3

Page 92: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

92 Options Guide TX300 S5

Installing a second processor Processors

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

9-0

02.fm

Figure 62: Inserting and locking the processor

Ê Hold the processor between your thumb and index finger and align it at the socket coding (see circle).

V CAUTION!

The processor can only be installed in one particular direction.

Ê Place the processor in the socket with great care (1).

V CAUTION!

Do not bend the spring contacts of the processor socket. Never touch the underside of the processor. Even light contaminants, such as oil from human skin, can destroy the processor or impair its functionality.

Ê Close the processor holder (2).

Ê Lock the processor in the socket by returning the spring clip to its original position (3).

2

1

3

Page 93: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 93

Processors Installing a second processor

Figure 63: Removing the protective cover

Ê Remove the protective cover on the underside of the heat sink.

V CAUTION!

Do not touch the thermal paste on the underside of the heat sink.

Page 94: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

94 Options Guide TX300 S5

Installing a second processor Processors

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

9-0

02.fm

Figure 64: Mounting and locking the heat sink

Ê Align the heat sink on the processor socket so that the side with the visible copper heat pipes is pointing in the direction of the memory slots.

Ê Fold down the two heat sink retaining clips at the same time and lock the heat sink by returning the heat sink retaining clips to their original position.

Ê Reinstall the fan bracket (see section "Installing the fan bracket" on page 123).

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

Page 95: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 95

Processors Replacing the processor

11.2 Replacing the processor

V CAUTION!

Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system.

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the fan bracket (see section "Removing the fan bracket" on page 33).

Removing the heat sink

Figure 65: Removing the heat sink

Ê Press the heat sink retaining clips downward and inward.

Ê Fold back the heat sink retaining clips (1).

Ê Loosen the heat sink by turning it back and forth and then lift it out (2).

Ê Remove the residual thermal paste from the underside of the heat sink.

Ê Clean the underside of the heat sink using a lint-free cloth.

2

1

1

Page 96: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

96 Options Guide TX300 S5

Replacing the processor Processors

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

9-0

02.fm

Removing an old processor

Figure 66: Removing an old processor

Ê Press the spring clip downward and outward.

Ê Fold back the spring clip (1).

Ê Fold back the processor holder (2).

Ê Lift the installed processor carefully out of the socket (3).

V CAUTION!

Do not bend the spring contacts of the processor socket.

3

1

2

Page 97: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 97

Processors Replacing the processor

Inserting and locking a new processor

Figure 67: Inserting and locking a new processor

Ê Hold the processor between your thumb and index finger and align it at the socket coding (see circle).

V CAUTION!

The processor can only be installed in one particular direction.

Ê Place the processor in the socket with great care (1).

V CAUTION!

Do not bend the spring contacts of the processor socket. Never touch the underside of the processor. Even light contaminants, such as oil from human skin, can destroy the processor or impair its functionality.

Ê Close the processor holder (2).

Ê Lock the processor in the socket by returning the spring clip to its original position (3).

2

1

3

Page 98: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

98 Options Guide TX300 S5

Replacing the processor Processors

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

9-0

02.fm

Figure 68: Applying and distributing thermal paste

Ê Apply a small amount of thermal paste to the upper side of the new processor.

Ê Ensure a thin and even distribution of the thermal paste.

Page 99: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 99

Processors Replacing the processor

Mounting and locking the heat sink

Figure 69: Mounting and locking the heat sink

Ê Align the heat sink on the processor socket so that the side with the visible copper heat pipes is pointing in the direction of the memory slots.

Ê Fold down the two heat sink retaining clips at the same time and lock the heat sink by returning the heat sink retaining clips to their original position.

Ê Reinstall the fan bracket (see section "Installing the fan bracket" on page 123).

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

Page 100: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

100 Options Guide TX300 S5

Replacing the heat sink Processors

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-433

9-0

02.fm

11.3 Replacing the heat sink

Ê Open the server (see chapter "Preparation" on page 23).

Ê Remove the fan bracket (see section "Removing the fan bracket" on page 33).

Ê Remove the heat sink (see section "Removing the heat sink" on page 95).

Ê Remove the protective cover from the new heat sink (see page 93).

Ê Install the new heat sink (see section "Mounting and locking the heat sink" on page 99).

Ê Reinstall the fan bracket (see section "Installing the fan bracket" on page 123).

Ê Close the server (see chapter "Completion" on page 123), connect it to the power outlet, and switch it on.

Page 101: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 101

12 Conversion from a floorstand model to a rack model

V CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

Ê Open the server and remove the front cover as described in chapter "Preparation" on page 23.

I The front cover is no longer required.

12.1 Removing the right-hand side cover

Figure 70: Removing the right-hand side cover

Ê Remove the screw on the server rear that secures the right side cover to the server enclosure.

Ê Push the hook up slightly using a screwdriver.

Ê Push the right-hand side cover in the direction of the arrow.

Ê Lift off the right-hand side cover.

Page 102: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

102 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

I The right-hand side cover is no longer required.

12.2 Removing the server feet

Ê If necessary, lay the server on its right-hand side.

Get a second person to help you do this. The server can weigh around 25 -40 kg (depending on the configuration).

Make sure that the server feet protrude over the table edge.

Figure 71: Removing the server feet

Ê Remove the four screws on each of the server feet (1).

Ê Remove the server feet.

I The server feet are no longer required.

1

11

1

Page 103: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 103

Conversion from a floorstand model to a rack model

12.3 Removing the foot mounting rail

Figure 72: Removing the foot mounting rail

Ê Loosen the three screws (1) of the foot mounting rail.

Ê Slide the foot mounting rail backward (2) until the hooks (a) unlock.

Ê Remove the foot mounting rail (3).

I The foot mounting rail is no longer required.

12.4 Accessible drives and operating panel module

The drive cage for the accessible drives is constructed in such a way that the accessible drives and the operating panel module can be taken out simply, turned through 90° to the left, and then be reinstalled.

Ê Remove the dummy covers from the drive cage (figure 19 on page 43).

Ê Unplug the cables from the system board or the accessible drives and remove the drives from the drive cage.

Ê Pull the operating panel module forward out if its mounting location until you can pull the I²C cable, the ribbon cable, and the USB cable out of the operating panel module. Remove the three cables.

Ê Remove the operating panel module.

a

1

1

1

3

2

Page 104: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

104 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Ê Turn the operating panel module through 90° to the left.

Figure 73: Installing the operating panel module

Ê Push the operating panel module halfway into the upper bay of the drive cage.

Ê Connect the I²C cable to the HDD backplane of Multibay 2 (X7 connector).

Ê Now push the operating panel module fully into the upper bay of the drive cage.

Ê Turn the drives removed beforehand through 90° to the left.

Ê Turn the dummy covers removed beforehand through 90° to the left.

Ê Install the drives and empty covers in the drive cage.

Ê Reestablish all connections to the drives.

Page 105: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 105

Conversion from a floorstand model to a rack model

12.5 Installing the ID Card holder

When converting the PRIMERGY TX300 S5 server to a rack mounted model, an additional ID card guide has to be installed. Installation will vary depending on the HDD configuration

Ê Remove all hot-plug hard disk drives (refer to the operating manual for a detailed description).

V CAUTION!

Ensure that all hard disk drives are uniquely identified so that you can reinsert them into their original bays after replacing the HDD backplane.

Page 106: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

106 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

12.5.1 Server with 3.5-inch hard disk drives

Figure 74: Removing the 3.5-inch HDD backplane (A)

Ê Disconnect all cables from the 3.5-inch HDD backplane (1).

Ê Loosen the knurled screw on the HDD backplane holder (2)

Ê Lift the backplane holder to disengage the centering pins (see arrows) on both sides (3).

3

2

3 1

1

Page 107: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 107

Conversion from a floorstand model to a rack model

Figure 75: Removing the 3.5-inch HDD backplane (B)

Ê Fold down the backplane holder in the direction of the arrow.

Page 108: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

108 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Figure 76: Removing the SCO hood guide

Ê Press down the latch on the left of the SCO hood guide (1) to disengage the locking mechanism.

Ê Fold the hood guide upwards (2) and unhook it.

12

Page 109: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 109

Conversion from a floorstand model to a rack model

Figure 77: Removing the HDD cage

Ê Remove the screws from the HDD cage (see circles).

Ê Remove the HDD cage from the housing.

V CAUTION!

Make sure that none of the intrusion switch cables are jammed or damaged!

Page 110: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

110 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Figure 78: Installing the ID Card holder

Ê Fit the ID Card holder into the housing so that the two guides (see circles) engage with the recesses on the server front (1).

Ê Secure the ID Card holder with one screw M3 x 4.5 mm (2).

1

2

Page 111: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 111

Conversion from a floorstand model to a rack model

Figure 79: Mounting the side cover intrusion switch (A)

Ê Carefully insert the HDD cage into the housing.

V CAUTION!

● Make sure that none of the intrusion switch cables are jammed or damaged!

● The intrusion switch cable connector must be routed towards the system board.

Ê Route the cable of the side cover intrusion switch around the HDD cage as shown.

Page 112: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

112 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Figure 80: Mounting the side cover intrusion switch (B)

Ê Mount the side cover intrusion switch (1) on the HDD cage.

Ê Fasten the two screws on the intrusion switch, securing it to the HDD cage (2).

Ê Completely slide the HDD cage into the housing.

Ê Secure the HDD cage and the included 2.5-inch HDD boxes with six (3.5-inch HDD configuration) or ten (2.5-inch HDD configuration) screws.

Ê Secure the rear side of the HDD cage with two captive screws.

1

2

Page 113: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 113

Conversion from a floorstand model to a rack model

Figure 81: Mounting the SCO hood guide

Ê Hook the SCO hood guide into the HDD cage as shown (1).

Ê Swivel the hood guide downwards (2) until it locks in place (3).

Ê Mount and cable the 3.5-inch HDD backplane.

Ê Insert all hot-plug hard disk drives in their original order.

1

23

Page 114: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

114 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

12.5.2 Server with 2.5-inch hard disk drives

Figure 82: Removing the SCO hood guide

Ê Press down the latch on the left of the SCO hood guide (1) to disengage the locking mechanism.

Ê Fold the hood guide upwards (2) and unhook it.

12

Page 115: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 115

Conversion from a floorstand model to a rack model

Figure 83: Removing the side cover intrusion switch and loosening the captive screws

Ê Loosen two screws on the side cover intrusion switch (1).

I Do not remove the screws completely!

Ê Move the intrusion switch to the right until it disengages from its guides and falls to the ground (2).

Ê Loosen the two captive screws on the HDD cage (green circles).

12

Page 116: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

116 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Figure 84: Removing the HDD cage

Ê Remove the screws from the HDD cage (blue circles).

Ê Carefully remove the HDD cage from the housing.

V CAUTION!

Make sure that none of the intrusion switch cables are jammed or damaged!

Page 117: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 117

Conversion from a floorstand model to a rack model

Figure 85: Installing the ID Card holder

Ê Fit the ID Card holder into the housing so that the two guides (see circles) engage with the recesses on the server front (1).

Ê Secure the ID Card holder with one screw M3 x 4.5 mm (2).

1

2

Page 118: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

118 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Figure 86: Mounting the HDD cage (A)

Ê Carefully insert the HDD cage into the housing (1).

V CAUTION!

Make sure that none of the intrusion switch cables are jammed or damaged!

Ê Route the cable of the side cover intrusion switch around the HDD cage as shown (2).

1

2

Page 119: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 119

Conversion from a floorstand model to a rack model

Figure 87: Mounting the intrusion switch

Ê Mount the side cover intrusion switch (1) on the HDD cage.

Ê Fasten the two screws on the intrusion switch, securing it to the HDD cage (2).

Ê Completely slide the HDD cage into the housing.

Ê Secure the HDD cage with the screws (M3 x 6 mm).

Ê Fasten two captive screws on the HDD cage.

1

2

Page 120: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

120 Options Guide TX300 S5

Conversion from a floorstand model to a rack model

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Figure 88: Mounting the SCO hood guide

Ê Hook the SCO hood guide into the HDD cage as shown (1).

Ê Swivel the hood guide downwards (2) until it locks in place (3).

Ê Mount and cable the 2.5-inch HDD backplane.

Ê Insert all hot-plug hard disk drives in their original order.

1

23

Page 121: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 121

Conversion from a floorstand model to a rack model

12.6 Final steps

Ê Attach the rack front cover (see section "Attaching the rack front cover" on page 130), close the server, connect it to the power outlet, and switch it on.

To enable the rack model to be presented correctly in ServerView Operations Manager, proceed as follows:

Ê Boot the system from PRIMERGY ServerView Suite DVD 1.

Ê In the first window, select your language settings, select "No status backup" under "Status backup media", and continue by choosing "Next".

Ê Read and accept the license terms.

Ê Continue with the guided/expert mode.

Ê Select "Tools - System Configuration Utilities - SCU Chassis Model Conversion" and convert the server type to rack mounted.

Page 122: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

0-0

02.fm

Page 123: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 123

13 CompletionV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 17.

13.1 Installing the fan bracket

Figure 89: Installing the fan bracket

Ê Insert the fan bracket in the server (1).

Ê Push the fan bracket in the direction of the arrow (2).

V CAUTION!

Ensure that you do not damage the SAS cables when inserting and sliding in the fan bracket.

2

2

1

Page 124: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

124 Options Guide TX300 S5

Installing the fan bracket Completion

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

1-0

02.fm

Figure 90: Fan bracket: connecting the power cable, fastening the knurled screws

Ê Connect the 10-pole plug of the power cable T26139-Y3952-V401 to the fan backplane (1).

Ê Secure the power cable with the cable clip (2).

Ê Fasten the fan bracket with the two knurled screws (3).

1 1

2

2

3

3

Page 125: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 125

Completion Floorstand model

13.2 Floorstand model

13.2.1 Mounting the server feet

Figure 91: Mounting the server feet

Ê Mount the server feet, if required.

To do this, you need to fasten four M3 x 6 mm screws to each of the server feet (see circles).

Page 126: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

126 Options Guide TX300 S5

Floorstand model Completion

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

1-0

02.fm

13.2.2 Attaching the front cover

After you have installed further accessible drives, reattach the front cover.

Figure 92: Attaching the front cover

Ê Hook the front cover in place at the top (see circles).

Ê Press the front cover against the housing in the direction of the arrow.

Page 127: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 127

Completion Floorstand model

Figure 93: Locking buttons engaging

Ê Press the two green locking buttons (1) until they engage.

11

Page 128: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

128 Options Guide TX300 S5

Floorstand model Completion

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

1-0

02.fm

Figure 94: Attaching the hard disk cover

Ê Hook the drive cover in place at the top and press it against the housing in the direction of the arrow (1).

Ê Hook the hard disk cover in place at the bottom and press it against the housing in the direction of the arrow (2).

13.2.3 Closing the server

I The left side cover closes easily when the server is in the horizontal position.

Ê Open the locking lever.

1

2

Page 129: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 129

Completion Floorstand model

Figure 95: Closing the server

Ê Lay the server on its right side.

Ask a second person to help you do this.The server can weigh up to 25-40 kg depending on its configuration.

Ensure that the feet project over the edge of the table.

Ê Place the left side cover on the server (1).

Ê Slide the side cover in the direction of the arrow (2) until you feel the locking lever click into place and the side cover is flush with the housing.

Ê Press the side cover against the housing and close the locking lever (3).

This pushes the side cover forward and locks it in place.

Ê Insert the key.

Ê Lock the server.

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

3

1 2

Page 130: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

130 Options Guide TX300 S5

Rack model Completion

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

1-0

02.fm

13.3 Rack model

13.3.1 Attaching the rack front cover

Reattach the rack front cover after implementing the following extensions:

– Installation of further accessible drives

– Conversion from a floorstand model to a rack model

Figure 96: Attaching the rack front cover

Ê Attach the rack front cover, together with the plastic front cover, from the front (1).

V CAUTION!

The rack front cover brackets are marked "Left" and "Right". Position the bracket marked "Left" on the left of the rack front.

Ê Attach the rack front cover using two M3 x 6 mm screws on each side (2).

2

2

1

Page 131: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 131

Completion Rack model

13.3.2 Closing the server

Ê Open the locking lever.

Figure 97: Closing the server

Ê Place the housing cover on the server (1).

Ê Slide the housing cover in the direction of the arrow (2) until you feel the locking lever click into place and the housing cover is flush with the housing.

Ê Press the housing cover against the housing and close the locking lever (3).

This pushes the housing cover forward and locks it in place.

3

1

2

Page 132: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

132 Options Guide TX300 S5

Rack model Completion

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

1-0

02.fm

If you have not removed the server from the rack cabinet, please skip this page.

Figure 98: Installing the server in a rack cabinet

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Do not use the handles on the rack front cover to lift the server into the rack.

Ê Lower the server onto the extended telescopic rails (1).

Ê Slide the server a little way in the direction of the arrow (2) until the hooks (a) of the telescopic rails engage. When doing this, ensure that the telescopic rails are kept in a locked position.

Ê Screw the telescopic rails to the server on the left and right side using one M3x6 screw on each side (3).

Ê Reconnect all the cables you disconnected beforehand on the rear of the server.

Ê Press in the safety springs of the telescopic rails (4) on both sides and push the server as far as it will go into the rack (5).

3

3

2

1

a

4

4

5

Page 133: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 133

Completion Rack model

Figure 99: Fastening the server in the rack cabinet

Ê Fasten the server in the rack using the two knurled screws (1).

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

1

1

Page 134: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

1-0

02.fm

Page 135: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 135

14 Appendix

14.1 Cabling

You will find suggestions for cabling on the next pages.

Page 136: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

136 Options Guide TX300 S5

Cabling Appendix

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

2-0

02.fm

Figure 100: Redundant power supply with 3.5-inch SAS hard disks

Legend:

Power

SAS/SA

TAU

SB / VG

AD

ata

COM 1COM 2USB

USB

VGA

CPU

1

LAN

1

Slot 7

Operation

panel A

3C40097567

On/Off-S

W

Stdby-Power-LED

HD-Activity-LED

Resetand

NMI

Identify

LED

CD-Rom

/ DVD

slimline

SAS-Bpl6 x 3,5“

A3C

40071451

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

intrusion-sw.

T26

139-Y

37

36-V

3 or –V4

Intrusion

T26

139-Y

396

3-V

1 /-V

21

T26

139-Y

396

3-V

1 /-V

21

iRM

C

DIP switches

battery

SAS

device

SATA

DVD

/ CD-Rom

half height

SAS

ML

Ch2

SAS

ML

Ch

1

Slot 1

Slot 2

Slot 3

Slot 5

Slot 6

LPC

MC

H

64K

Chassis

IDPROM

A3C40096564

SAS

MLC

1

SAS

MLC2

X2

X1

CSS

LED

/

Localviewpanel

T26139-Y3952-V251

Con.4

Con.5

Con.6

Multibay 1

Con.3

RAID

controllerbatterypack 2

RAID

controllerbatterypack 1

T26

139-Y

3987-V

1

SAS

Controller 2

-Y3990-V

1

intrusion-sw.

Slot 4

CPU

2

USB

USB

LAN

2

LAN

3LA

N

SATA1

DC/DC Converter

A3C40097569

Fan board

A3C40096234

T26

139-Y

3952-V25

1

T26139-Y3994-V1

T26

139-Y

3807-V2

12

T26139-Y3925-V401

T26139-Y3958-V205

or -Y3928-V205

TylersburgEP

3x USB

A3C40

100506

USB stick

Con.9

VGA

3 x

fan

adapter

-Y3940-

V40

1buzzer

T26

139-Y

3969-V202

to SAS

controller

batterypack

Con.2

SATA2

Front USB

USB INT 1

USB INT 2

Front VGA

Frontpanel

X1

X2Con.1

Con.2

X1

Con.3

Con.1

HD

/ FAN

X1

1

X10

X9

*1)

*1)

*2)

alternative

power connectors

*1

= Con.3

or Con.5

*2 =

Con.2

or Con.4

or Con.6

SAS

Controller 3

T26

139-Y

3987-V

1

Battery

pack 3

Page 137: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 137

Appendix Cabling

Figure 101: Redundant power supply with twenty 2.5-inch SAS hard disks

Legend:

Power

SAS/SA

TAU

SB / VG

AD

ata

COM 1COM 2USB

USB

VGA

CPU

1

LAN

1

Slot 7

Operation

panel A

3C40097567

On/Off-S

W

Stdby-Power-LED

HD-Activity-LED

Resetand

NMI

Identify

LED

CD-Rom

/ DVD

slimline

SAS-Bpl12 x 2,5“

A3C

40088726

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

intrusion-sw.

T26

139-Y

37

36-V

3 or –V4

Intrusion

T26

139-Y

396

3-V

10

3

iRM

C

DIP switches

battery

SAS

ML

Ch

1

Slot 1

Slot 2

Slot 3

Slot 5

Slot 6

LPC

MC

H

64K

Chassis

IDPROM

A3C40096564

SAS

MLC

1

SAS

MLC2

X14

X1

CSS

LED

/

Localviewpanel

T26139-Y3952-V152

Con.4

Con.5

Con.6

Multibay 1

Con.3

RAID

controllerbatterypack 2

RAID

controllerbatterypack 1

T26

139-Y

3987-V

1

SAS

Controller 2

-Y3990-V

1

intrusion-sw.

Slot 4

CPU

2

USB

USB

LAN

2

LAN

3LA

N

SATA1

DC/DC Converter

A3C40097569

Fan board

A3C40096234

T26

139-Y

3952-V25

1

T26139-Y3994-V1

T26

139-Y

3807-V2

12

T26139-Y3925-V401

TylersburgEP

3x USB

A3C40

100506

USB stick

VGA

3 x

fan

adapter

-Y3940-

V40

1buzzer

2 x

T26

139-Y

396

3-V

105

X17

X15

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

2x4xSAS HDD 2.5“

2 x

T26

139-Y2

19

3-V

11

1

or T26

139-Y2

19

3-V2

11

X1

X1

batterypack

to SAS

controller

T26139-Y3958-V205

or -Y3928-V205

Con.2

SATA2

Front USB

USB INT 1

USB INT 2

Front VGA

Frontpanel

X1

left

X1

right

MLC

1

MLC2

MLC

1

X1

left

MLC2

X

1 right

HD

/ FAN

Con.1

X1

Con.3

X1

Con.2

X2Con.1

alternative

power connectors

*1

= Con.3

or Con.5

*2 =

Con.2

or Con.4

or Con.6

Con.9

or Con.10

Con.9

or Con.10

*2)

*2) *2)

battery

pack 3

SAS

Controller 3

T26

139-Y

3987-V

1

Page 138: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

138 Options Guide TX300 S5

Cabling Appendix

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

2-0

02.fm

Figure 102: Redundant power supply with eight 3.5-inch SAS hard disks and USB drive

Legend:

Power

SAS/SA

TAU

SB / VG

AD

ata

COM 1COM 2USB

USB

VGA

CPU

1

LAN

1

Slot 7

Operation

panel A

3C40097567

On/Off-S

W

Stdby-Power-LED

HD-Activity-LED

Resetand

NMI

Identify

LED

SAS

–HDD

1“

SAS-Bpl6 x 3,5“

A3C

40071451

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

intrusion-sw.

T26

139-Y

37

36-V

3 or –V4

Intrusion

T26

139-Y

396

3-V

1 /-V

21

T26

139-Y

396

3-V

1 /-V

21

iRM

C

DIP switches

battery

CSS

LEDs/ LocalView

Operation

panel

SAS

ML

Ch2

SAS

ML

Ch

1

Slot 1

Slot 2

Slot 3

Slot 5

Slot 6

LPC

MC

H

64K

Chassis

IDPROM

A3C40096564

SAS

MLC

1

SAS

MLC2

X2

X1

CD-ROM/ DVD

/ Slimline

T26139-Y3952-V251

alt. - Y3952-V152

Con.3

Con.5

Con.6

SAS 2x3,5“-HDD

extension box

Con.4

RAID

controllerbatterypack 2

RAID

controllerbatterypack 1

T26

139-Y

3987-V

1

SAS

Controller 2

-Y3990-V

1

intrusion-sw.

Slot 4

CPU

2

USB

USB

LAN

2

LAN

3LA

N

SATA1

DC/DC Converter

A3C40097569

Fan board

A3C40096234

T26

139-Y

3952-V25

1

T26139-Y3994-V1

T26

139-Y

3807-V2

12

T26139-Y3925-V401

TylersburgEP

3x USB

A3C40

100506

USB stick

Con.9

VGA

3 x

fan

adapter

-Y3940-

V40

1buzzer

T26

139-Y

397

3-V2

to SAS

controller

batterypack

SAS

–HDD

1“

USB

device–half height

MLC

3

USB INT 1

USB INT 2

SATA2

Front USB

T26

139-Y

3968-V

1

T26139-Y3958-V205

or -Y3928-V205

Con.2

Front VGA

Frontpanel

HD

/ FAN

Con.1

X1

Con.3

X1

Con.2

X2Con.1

X1

1

X10

X9

*2)

*2)

*2)

X5 X7

X1

X1

alternative

power connectors

*1

= Con.3

or Con.5

*2 =

Con.2

or Con.4

or Con.6

battery

pack 3

T26

139-Y

3987-V

1

SAS

Controller 3

Page 139: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 139

Appendix Cabling

Figure 103: Redundant power supply with eight 3.5-inch SAS hard disks and SCSI drive

Legend:

Power

SAS/SA

TAU

SB / VG

AD

ata

COM 1COM 2USB

USB

VGA

CPU

1

LAN

1

Slot 7

Operation

panel A

3C40097567

On/Off-S

W

Stdby-Power-LED

HD-Activity-LED

Resetand

NMI

Identify

LED

SAS

–HDD

1“

SAS-Bpl6 x 3,5“

A3C

40071451

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

SAS-HD

1“

intrusion-sw.

T26

139-Y

37

36-V

3 or –V4

Intrusion

T26

139-Y

396

3-V

1 /-V

21

T26

139-Y

396

3-V

1 /-V

21

iRM

C

DIP switches

battery

CSS

LEDs/ LocalView

Operation

panel

SAS

ML

Ch2

SAS

ML

Ch

1

Slot 1

Slot 2

Slot 3

Slot 5

Slot 6

LPC

MC

H

64K

Chassis

IDPROM

A3C40096564

SAS

MLC

1

SAS

MLC2

X2

X1

CD-ROM/ DVD

/ Slimline

T26139-Y3952-V251

alt. - Y3952-V152

Con.3

Con.5

Con.6

SAS 2x3,5“-HDD

extension box

Con.4

RAID

controllerbatterypack 2

RAID

controllerbatterypack 1

T26

139-Y

3987-V

1

SAS

Controller 2

-Y3990-V

1

intrusion-sw.

Slot 4

CPU

2

USB

USB

LAN

2

LAN

3LA

N

SATA1

DC/DC Converter

A3C40097569

Fan board

A3C40096234

T26

139-Y

3952-V25

1

T26139-Y3994-V1

T26

139-Y

3807-V2

12

T26139-Y3925-V401

TylersburgEP

3x USB

A3C40

100506

USB stick

Con.9

VGA

3 x

fan

adapter

-Y3940-

V40

1buzzer

to SAS

controller

batterypack

SAS

–HDD

1“

SCSI device

MLC

3

USB INT 1

USB INT 2

SATA2

Front USB

T26

139-Y

3968-V

1

T26139-Y3958-V205

or -Y3928-V205

SCSI

Controller

T26

139-Y

3967-V

10

1

or T26

139-Y

3980-V

11

Con.2

Front VGA

Frontpanel

HD

/ FAN

Con.1

X1

Con.3

X1

Con.2

X2Con.1

X1

1

X10

X9

*2)

X5

X1

*2)

*2)

X1

alternative

power connectors

*1

= Con.3

or Con.5

*2 =

Con.2

or Con.4

or Con.6

battery

pack 3

T26

139-Y

3987-V

1

SAS

Controller 3

Page 140: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

2-0

02.fm

Page 141: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

TX300 S5 Options Guide 141

IndexAaccessible drives

attaching EasyClick rails 45detaching EasyClick rails 44DVD burner 11DVD drive 11equipping bays 41, 42installing Multibay 1 54magnetic tape drive 11removing dummy cover 43ServerView Local Service

Display 11appendix 135

BBattery Backup Unit 69BBU 12

installing 69

Ccabling 135cabling plan 135conversion

floorstand to rack model 12, 101

Ddual operation 89, 95

EEasyClick rails

attaching 45detaching 44

electrostatic-sensitive devices (ESD) 22

equipping bays 41, 42equipping rules

main memory 35ESD (electrostatic-sensitive

devices) 22

expanding main memory 35expansion card 12

BBU 69installing 66

Ffan bracket

installing 123removing 33

floorstand modelattaching front cover 126closing 128mounting server feet 125opening 23removing front cover 24removing server feet 28

floorstand to rack modelconversion 12, 101

front coverattaching 126removing 24

HHDD extension box

2.5-inch hard disks 583.5-inch hard disks 58

Hood guide 108, 113, 114, 120

Iinformation, additional 9Intrusion switch

Side 112, 115, 118

Llaser information 21light emitting diode (LED) 21lithium battery 20LSD 12, 47LSP 12, 47

Page 142: PRIMERGY TX300 S5 - Fujitsumanuals.ts.fujitsu.com/file/8497/tx300s5-og-en.pdf · – "PRIMERGY ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" manual

142 Options Guide TX300 S5

Index

© c

ogn

itas.

Ge

sells

chft

für

Tech

nik-

Dok

um

enta

tion

mbH

200

9 P

fad

: C:\P

rogr

amm

e\F

CT

\tim

_ap

p\tim

_loc

al\w

ork

\JE

SU

S\O

BJ_

DO

KU

-434

3-0

02.fm

Mmain memory

equipping rules 35expanding 35

meaning of the symbols 13multi-processor operating

system 89, 95Multibay 1

equipping 47installing 54installing DVD drive 50installing LSD 48installing LSP 48

Multibay 2 58installing 60

Nnotational conventions 13

Rrack front cover

attaching 130removing 32

rack modelopening 29removing rack front cover 32

RAID key 12inserting 87

removing dummy cover 43

SSAS/SATA RAID controller

BBU 69inserting RAID key 87

SCO hood guide 108, 113, 114, 120server

closing 128opening 23, 29

server feetmounting 125removing 28

ServerView Local Service Display 12, 47

ServerView Local Service Panel 12, 47

Ttarget group 7TPM 11TPM module

installing 83scope of delivery 83

Trusted Platform Module 11, 83