4
CTA: 45528 45578 Amsler HIT 230F drop weight tester equipped for multiaxial puncture test Impact body with clamping ring and sample The small drop weight tester for puncture tests With a maximum impact speed of 4.4 m/s and a drop weight of 23.5 kg, this drop weight tester is ideally suited for puncture tests to ISO 6603-2. One impressive feature is the excellent test area accessibility, enabling rapid completion of test series including direct feeding of temperature-conditioned test plates. When it comes to efficiency and ergonomics, this drop weight tester can't be beat. Range of application The Amsler HIT230F is ideally equipped for multiaxial impact puncture tests on plastics. Its range of application includes material characteriza‐ tion of standard specimens in accordance with estab‐ lished standards in research and development and quality assurance. • Multiaxial impact puncture tests to ISO 6603-2, ASTM D 3763, at room temperature and in extended temperature range. Advantages and features • Safe, easy, reliable operation • Good access to test area. • Design allows flexible use of accessories plus easy changeover. • Intelligent safety system – no need to operate safety door when inserting specimens. • Innovative clamping system enables fast, easy specimen clamping. • Tests possible over a wide temperature range without installing an expensive temperature chamber in the test frame. • Cost-effective external specimen temperature-condi‐ tioning can be employed and/or existing devices in the laboratory can continue in use. • Innovative design throughout the force-measurement chain delivers very low-noise measured values, enabling reliable identification of characteristic mate‐ rials properties in the force-deformation curve. • Safety device plus operator-friendly specimen clamping for high specimen throughput. • The drop weight is raised automatically; the drop height can be set as required in a range from 0.1 m to 1 m. • High (4 MHz) measured-value acquisition-rate combined with high (16-bit) resolution. Basic instrument includes: • Evaluation electronics • Fixed safety device (front and rear) • Drop weight of 23.5 kg Product Information Amsler HIT230F drop weight tester for multiaxial puncture test PI 682 1117

Product Information Amsler HIT230F drop weight tester for ...€¦ · Amsler HIT 230F drop weight tester equipped for multiaxial puncture test Impact body with clamping ring and sample

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Information Amsler HIT230F drop weight tester for ...€¦ · Amsler HIT 230F drop weight tester equipped for multiaxial puncture test Impact body with clamping ring and sample

CTA

: 455

28 4

5578

Amsler HIT 230F drop weight tester equipped for multiaxial puncturetest

Impact body with clamping ring and sample

The small drop weight tester for puncture testsWith a maximum impact speed of 4.4 m/s and a dropweight of 23.5 kg, this drop weight tester is ideallysuited for puncture tests to ISO 6603-2. One impressivefeature is the excellent test area accessibility, enablingrapid completion of test series including direct feedingof temperature-conditioned test plates. When it comesto efficiency and ergonomics, this drop weight testercan't be beat.

Range of applicationThe Amsler HIT230F is ideally equipped for multiaxialimpact puncture tests on plastics.

Its range of application includes material characteriza‐tion of standard specimens in accordance with estab‐lished

standards in research and development and qualityassurance.

• Multiaxial impact puncture tests to ISO 6603-2, ASTMD 3763, at room temperature and in extendedtemperature range.

Advantages and features• Safe, easy, reliable operation• Good access to test area.• Design allows flexible use of accessories plus easy

changeover.

• Intelligent safety system – no need to operate safetydoor when inserting specimens.

• Innovative clamping system enables fast, easyspecimen clamping.

• Tests possible over a wide temperature range withoutinstalling an expensive temperature chamber in thetest frame.

• Cost-effective external specimen temperature-condi‐tioning can be employed and/or existing devices inthe laboratory can continue in use.

• Innovative design throughout the force-measurementchain delivers very low-noise measured values,enabling reliable identification of characteristic mate‐rials properties in the force-deformation curve.

• Safety device plus operator-friendly specimenclamping for high specimen throughput.

• The drop weight is raised automatically; the dropheight can be set as required in a range from 0.1 m to1 m.

• High (4 MHz) measured-value acquisition-ratecombined with high (16-bit) resolution.

Basic instrument includes:• Evaluation electronics• Fixed safety device (front and rear)• Drop weight of 23.5 kg

Product InformationAmsler HIT230F drop weight tester for multiaxial puncture test

PI 6

82 1

117

Page 2: Product Information Amsler HIT230F drop weight tester for ...€¦ · Amsler HIT 230F drop weight tester equipped for multiaxial puncture test Impact body with clamping ring and sample

Technical data

Type Amsler HIT230F drop weight tester

Item No. 1078760

Potential energy 230 J

Dimensions

Height 2600 mm

Width 1000 mm

Depth 600 mm

Drop height, max. 1000 mm

Drop height, min. 110 mm

Drop weight 23.3 kg

Impact velocity, max. 4.4 m/s at 1 m dropheight

Force signal resolution 16 bit

Measured-value rate (force signal), max. 4 MHz

Gripping force 6 ... 9 kN

Weight, approx. 400 kg

Floor load (applied via the load frame surface) 20 kN/m²

Concentrated load of the leveling feet 200 N/cm²

Average noise level of drive at vmax measured at 1 m distancefrom the front of the machine

60 dB(A)

Electrical supply data

Power supply 100 to 240 V

Phases 1Ph/N/E

Permissible voltage fluctuation ± 10 %

Power consumption (full load), approx. 0.5 kVA

Power supply frequency 50/60 HzCompressed air supply

Pressure 5 to 8 bar

Compressed air consumption (compressed air) per impact ortest

2 l

Required air-supply output-rate 600 l/min

Compressed air connection side DN 7

Maintenance unit mounted on instrument

Accessories required

Clamping rings (1x required)

Type Standard Dimensions Clamping sur‐face

Scope of deliv‐ery

Item No.

Diameter, inner[mm]

Clamping rings - 20 Grooved 1 pair 1044076

Clamping rings ISO 6603-2 40 Grooved 1 pair 1044077

Clamping rings ASTM D3763 76 Grooved 1 pair 1044078

Product InformationAmsler HIT230F drop weight tester for multiaxial puncture test

We reserve the right to make technical changes in the course of ongoingdevelopment.

All data at ambient temperature.

Page 3: Product Information Amsler HIT230F drop weight tester for ...€¦ · Amsler HIT 230F drop weight tester equipped for multiaxial puncture test Impact body with clamping ring and sample

Additional clamping rings on request

Mounts for clamping rings (1x required)Description Item number

Mount for clamping rings with 20 mm and 40 mm inner diameter. 1044079

Mount for clamping rings with 76 mm (3”) inner diameter. 1044080

Impactor for multiaxial puncture test (1x required)

• Complete impactor is easily interchangeable• Impactor tip can be changed• Instrumentation with piezoelectric sensors• Guarded axial terminal for measuring lead

Standard Impactor tip Nominal force Fnom

[kN1)]

Item No.

Diameter[mm]

ISO 6603-2 20 15 1044071

ISO 6603-2 10 9 1044074

ASTM D3763 12.7 15 1044075

1) The basic instrument has two measurement ranges: 10%/100% of the maximum force. An additional measurement range can be coveredwith a load cell.

CTA

: 455

77 4

5580

Force/deformation diagram Impactor with clamping ring

Product InformationAmsler HIT230F drop weight tester for multiaxial puncture test

We reserve the right to make technical changes in the course of ongoingdevelopment.

All data at ambient temperature.

Page 4: Product Information Amsler HIT230F drop weight tester for ...€¦ · Amsler HIT 230F drop weight tester equipped for multiaxial puncture test Impact body with clamping ring and sample

CTA

: 455

53 4

5589

Motorized drop weight lift, pneumatic release mechanism Safe two-handed operation

Optional accessories

Specimen cooling box

Item No. 1082994

This cool box is typical of those used for tests on plastics, but can in principle be used for any material.

CTA

: 454

89 4

5487

Specimen cool box

Product InformationAmsler HIT230F drop weight tester for multiaxial puncture test

We reserve the right to make technical changes in the course of ongoingdevelopment.

All data at ambient temperature.