Ventilation Air Conditioning RefrigerationHeating
22ºCInside
OUTSIDEHUMIDITY
PROVIDED BYHEINEN & HOPMAN
35 C
90%
productsBooster cooler (for submarine)
Alternatives available on request.Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Booster Cooler
General informationThe Booster Cooler’s function is to keep the internal air of the electrical room at the defined temperature. The Booster Cooler is not designed for cooling of the accommodation but for unmanned spaces. For example, at electrical rooms or other unmanned spaces where the crew occasionally visits for maintenance. To avoid overheating the Booster Cooler extracts air e.g. from the electrical room and cools the air to its set point temperature.
The Booster Cooler is suitable for military vessels due to the following characteristics:• compact design• low noise• electronic magnetic control (EMC)• shock qualification MIL-S-901
Primary circuit (chilled water)
Temperature Min: +8°C Max: +13°C
Set point air temp +18 °C ± 1°C
environment/ storage
Temperature Min: -25°C Max: +70°C
Operation temp. Min: +0°C Max: +40°C
General specification
Cooling capacity 2.86 kW
Max air flow 550 m3/h
Static pressure ± 250 Pa
Sound level ~55dB(A)
Protection class IP65
Dimensions L x W x H 600 x 400 x 1000 mm
Operating weight ± 100 kg
Power supply 1ph / 440V / 60Hz
Other cooling capacity and power supply available on request.
technical specifications
Revision A Status: Finished Page 10 of 65
4. General Description BC
This chapter gives a general description of the BC itself and components which are installed inside the BC.
4.1. General Unit Description
The BC function is to keep the internal air of the electrical room in the defined temperature set point of +18 °C ± 1 °C. The electronics room where the BC operates is in principle an unmanned space. The maintenance crew occasionally visits the electronics room. To avoid overheating of this room, the BC extracts air from the electronics room and cools the air. To cool the air to the defined state of +18 °C ± 1 °C, the heat-exchanger uses 500 liter cooling water per hour and cools it white a cooling capacity of 2.86 kW.
Figure 4-1: Principal BC
to serve the fleet with the most reliable
HVAC systems
“ “
www.heinenhopman.com
Heinen & Hopman encourages a more
sustainable world. By providing eco-friendly solutions and serviceswe offer our clients
the option of reducing energy consumption
and thus co2 emissions. Visit
greenmanifest.info for more information.
BrazilT: +5521 3587 4241/4244E: [email protected]
France - la CiotatT: +334 4204 8685E: [email protected]
France - GrasseT: +336 3090 7786 E: [email protected]
GermanyT:+49 4073 1680E: [email protected]
IndiaT: +9133 6499 1293E: [email protected]
ItalyT: +3901 8745 7970E: [email protected]
the Netherlands (HQ)T: +313 3299 2500E: [email protected]
the Netherlands (rotterdam)T: +317 8890 8050E: [email protected]
NorwayT: +47 6919 0900E: [email protected]
Peoples republic of ChinaT: +8621 3253 2896E: [email protected]
Peoples republic of ChinaT: +86 510 8528 1763E: [email protected]
PolandT: +489 1433 1800E: [email protected]
romaniaT: +402 3644 8222E: [email protected]
russiaT: +7 (4012) 308 801E: [email protected]
singaporeT: +65 6897 7879E: [email protected]
south KoreaT: +8270 4901 0000E: [email protected]
spainT: +349 3225 9668E: [email protected]
swedenT: +46 3121 7500E: [email protected]
turkeyT: +9021 6493 8118E: [email protected]
UAe (Abu Dhabi) T:+971 2550 4147E: [email protected]
UAe (Dubai)T: +971 4263 5453E: [email protected]
UsA - Fort lauderdale, FloridaT: +195 4463 0110E: [email protected]
UsA - Houma, louisiana T: +198 5876 7989E: [email protected]