1 Progress in Digital Radiology Ewert April 2007 Progress of Digital Industrial Radiology by Uwe Ewert [email protected] http://www.bam.de INDE 2007 India, Chennai, April 25th , 2007

Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

1

Progress in Digital Radiology EwertApril 2007

Progress of Digital Industrial Radiology

byUwe Ewert

[email protected]://www.bam.de

[email protected]://www.bam.de

INDE 2007India, Chennai, April 25th , 2007

Page 2: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

2

Progress in Digital Radiology EwertApril 2007

• Film replacement• Computed Radiography (CR) with phosphor imaging plates – High

Definition Computed Radiography (HD CR)• Digital Detector Arrays (DDA)

• High Contrast Sensitivity Radiography with DDAs• Automated Defect recognition

• Dual energy technique• X-ray back scatter technique (BS RT)• X-Ray Modeling and POD• Portable Computed Tomography for

• Nuclear power plants• Large flat components in Aircraft industry

• Small angle scatter CT and nano CT at Synchrotron• Motion neutron - radiography

Page 3: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

3

Progress in Digital Radiology EwertApril 2007

Film Replacement

Computed Radiography (CR) with phosphor imaging plates – high definition CR

Page 4: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

4

Progress in Digital Radiology EwertApril 2007

Reporting

Archive

Networking

Digital Detector Arrays

Film Digitizer

ImagingPlates

Data TransmissionScannerfor Imaging Plates

Hard CopyGrayscalePrinter Agfa

INDO-GERMAN Workshop on DIR 1999

Computed RadiographyStandards available now

Radiology with Digital Detector Arrays

Graph of:

Page 5: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

5

Progress in Digital Radiology EwertApril 2007

Motivation for Film Replacement by Computed Radiography and DDA‘s

Motivation for Film Replacement by Computed Radiography and DDA‘s

• Shorter test and interpretation time

• New application areas by higher inspection quality and wall thickness range

• No chemicals and dangerous waste

• Less consumables

Film (D4)

Flachdetektor (Hamamatsu)

Page 6: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

6

Progress in Digital Radiology EwertApril 2007

Filmless Radiography

Computed Radiography withPhosphor Imaging Plates

Page 7: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

7

Progress in Digital Radiology EwertApril 2007

The Imaging Plate CycleThe Imaging Plate Cycle

Exposure of Imaging Plate

Imaging Plate

Cassette

Lead filter

Exposure

Scanning the IP , Digitising and Erasing the residual Image

Processing Station

INDO-GERMAN Workshop on DIR 1999

Page 8: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

8

Progress in Digital Radiology EwertApril 2007

Radiography (CR) with Phosphor Imaging PlatesASME CR Code Case 2476

First digital catalogue, light alloy castingdigitized films from ASTM E 155 (BAM)

ASTM E 2422

DDA under developmentASTM E 07

Part 1: Classification of Systems, Part 2: General principles

EN 14784 CR

RadioscopyEN 13068

Film DigitisationEN 14096, ISO 14096

Classification (E 2446), Long term stability (E2445), Guide (E 2007), Practice (E 2033)

ASTM CR

New Standards on Digital Industrial Radiology

Page 9: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

9

Progress in Digital Radiology EwertApril 2007

EN 14784-2

System Selection

Page 10: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

10

Progress in Digital Radiology EwertApril 2007

Filmless Radiography

CR Applications

Page 11: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

11

Progress in Digital Radiology EwertApril 2007

High Definition CR Systems for Welding

HD CR:„VistaScan“, of Duerr, Germany

FUJI IP‘s, light blue

Systems available down to• 12 µm pixel pitch and • < 40 µm unsharpness

• “weld quality”

BAM 5: 8 mm steel

Page 12: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

12

Progress in Digital Radiology EwertApril 2007

•36 inch 12.7 mm Wall thickness Pipe Weld (SWSI-panoramic exposure )

Digital Radiography for Pipeline Testing

FilmFree meeting17.04.2007

Page 13: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

13

Progress in Digital Radiology EwertApril 2007

f = film focus distancer = outer pipe radiusR = outer radius of insulationw = projection of wall thickness

w on the detector planeVEBA-OEL 2000

Corrosion and Wall Thickness Measurement:Corrosion and Wall Thickness Measurement:

Page 14: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

14

Progress in Digital Radiology EwertApril 2007

Wall Thickness MeasurementWall Thickness Measurement

Tangential Radiographic Technique(TRT)

Tutorial at 24.04.2007INDE2007, Chennai

Page 15: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

15

Progress in Digital Radiology EwertApril 2007

High Energy X-Ray Inspection in Lieu of Manual Maintenance Check of Large Components

Page 16: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

16

Progress in Digital Radiology EwertApril 2007

Filmless Radiography

Flat Panel Detectorsand the new

High Contrast Sensitivity TechniqueHCS-RT

Page 17: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

17

Progress in Digital Radiology EwertApril 2007

New Flat-Panel Detector TechnologyNew Flat-Panel Detector Technology

Spahn 97

New DevelopmentsNew Developments

Page 18: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

18

Progress in Digital Radiology EwertApril 2007

SNRnorm

Current limit of film and CR technology

SNR limit by materials structure

High Contrast Sensitivity TechniqueEffect of Correct Calibration Procedures

DDAs exceed film quality!

Page 19: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

19

Progress in Digital Radiology EwertApril 2007

Film and Flat Panel Detector for the BAM 5 Weld.

ASTM E2002 duplex wireASTM E1025 Inconel5 Hole Penetrameter

ASTM E747 / EN 462-2Fe 13 Wire Penetrameter

EN 462-2 Step Hole Type IQI „H1“

BAM 5 is a hand welded steel plate (St 35) 8 mm thick, the welding seam is max. 10 mm thick. It contains all types of welding flaws, especially nice cracks at the surface of the welding seam.

Page 20: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

20

Progress in Digital Radiology EwertApril 2007

Fuji IX25SNRnorm~ 265

PerkinElmer 1620SNRnorm~ 1500

by K. Bavendiek et all.

Page 21: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

21

Progress in Digital Radiology EwertApril 2007

Fast Test of Heat Exchangerswith

Tiled DDA

Page 22: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

22

Progress in Digital Radiology EwertApril 2007

WLE/AD - Plant Inspection, Welding Engineering; PVT Meeting Freeport 2004 14

RT-testing of tube-to-tube-sheet jointsGammat B3

Ir 192, Radiator: 1 x 0.5 mm²

Possible tube dimensions: 12*1.5 up to 76.1*4 (diameter*thickness)Materials: carbon and stainless steel, Ni-alloys, Zr, (Ti, Ta)Joint design shall be considered

Page 23: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

23

Progress in Digital Radiology EwertApril 2007

X-ray tube Warrikhoff MCTS 130A-0,6 and CdTe-Detector Ajat DIC100TH

Practice test:

Testing of Heat Exchanger Weldswith a specialised Digital Detector ArrayThrough the Detector

Testing of Heat Exchanger Weldswith a specialised Digital Detector ArrayThrough the Detector

Alekseychuk, Zscherpel, Rost

Page 24: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

24

Progress in Digital Radiology EwertApril 2007

D4 film with 130 kV:1 min (1mm Sn filter)

X-Ray tube with DIC100TH detector75 kV, 0,5 mA, 10s

Research-Project BASF/Ajat/BAM since 2006, first results on test weld

Page 25: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

25

Progress in Digital Radiology EwertApril 2007

Imaging and Materials Characterisation

with

Dual Energy Technique

Page 26: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

26

Progress in Digital Radiology EwertApril 2007

Explosive Detection by Dual-Energy-RadiologyExplosive Detection by Dual-Energy-Radiology

Baggage-transport

Typical device for explosive detection of baggage and fin postal service

(Smiths Heimann)

Smiths Heimann

Fan beams at two different energies

L-line detectors

Page 27: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

27

Progress in Digital Radiology EwertApril 2007

Dual-Energy-Technique for Plastics and Composite PipesDual-Energy-Technique for

Plastics and Composite Pipes

Inspection of a multi layer pipe, made from different plastics and with partial glass fibre reinforcement for chemical industry

Page 28: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

28

Progress in Digital Radiology EwertApril 2007

X-Ray Back Scatter Techniquefor

Security and Aircraft Industry

Page 29: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

29

Progress in Digital Radiology EwertApril 2007

X-ray Back Scatter Technique:

- Advantage is the single sided access

- Comscan – Technique was too slow and was applied only in very few areas

- New evaluation of back scatter technique due to the success in the security field

- New technologies are under development, e.g. in aircraft industry

Page 30: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

30

Progress in Digital Radiology EwertApril 2007

X-Ray Back Scatter Techniquewith single sided access

X-Ray Back Scatter Techniquewith single sided access

AS&E

Page 31: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

31

Progress in Digital Radiology EwertApril 2007

X-Ray Back Scatter Techniquewith Single Sided AccessX-Ray Back Scatter Techniquewith Single Sided Access

Organic materials are visible with high contrast

Flying Spot Unit

AS&E

Page 32: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

32

Progress in Digital Radiology EwertApril 2007

X-Ray Back Scatter Technique

Source: http://www.as-e.com Accepted e.g. in UK on voluntary basis

Page 33: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

33

Progress in Digital Radiology EwertApril 2007

Backscatter image of a personSource: http://www.as-e.com

Not accepted due to European Radiation Safety Regulations

1 µRem = 0,01 µSv

Radiation protection permits:1 mSv/year (100 mRem/year)for population but not without justification!

X-Ray Back Scatter Technique

Page 34: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

34

Progress in Digital Radiology EwertApril 2007

X-Ray Back Scatter – Flying Spot TechniqueX-Ray Back Scatter – Flying Spot Technique

Letter bomb dummy

Lange, Hentschel, BAM

Page 35: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

35

Progress in Digital Radiology EwertApril 2007

Terahertz (THz): Letter Bomb DummyTerahertz (THz): Letter Bomb DummyX- ray image

THz-Image

Kupsch, Lange, Beckmann,Hentschel

Page 36: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

36

Progress in Digital Radiology EwertApril 2007

Back Scatter Technique with specialized DiaphragmBack Scatter Technique with specialized Diaphragm

Diaphragm

Imaging plate/Detector Array

Shielding box

Camera

X-ray tube

Osterloh01/2007

Page 37: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

37

Progress in Digital Radiology EwertApril 2007

Fast Back Scatter Technique with Specialized DiaphragmFast Back Scatter Technique with Specialized Diaphragm

Water in Honeycomb

Page 38: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

38

Progress in Digital Radiology EwertApril 2007

Water in Honeycomb-StructuresWater in Honeycomb-Structures

Radiograph

Back scatter image Planar-tomogram

Page 39: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

39

Progress in Digital Radiology EwertApril 2007

Detector

Collimator

Backscattersystem of InnospeXion

New Equipment

Combination of

• High sensitive DDA and

• Specialised collimator

Page 40: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

40

Progress in Digital Radiology EwertApril 2007

X-Ray Modeling for- Film replacement

- Planning of testing

- POD

X-Ray Modeling for- Film replacement

- Planning of testing

- POD

Page 41: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

41

Progress in Digital Radiology EwertApril 2007

Modelling ToolsModelling Tools

Surface presentation • Interface to CAD and CT• Separation of homogeneous regions• Arrangement of different Polygons in the virtual scene

Processes:• Absorption• Compton-Scatter / Rayleigh-Scatter• Interaction by Collision probability

m>0

m=0

s1

s2

s3object

detector

(E0,W0)

Source

Object

Detector

Jaenisch, Bellon

Page 42: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

42

Progress in Digital Radiology EwertApril 2007

Complex Geometry: Cardan jointSimulation-Example

Pore

Page 43: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

43

Progress in Digital Radiology EwertApril 2007

Surface scan @ BAM VIII.1

• Strip projection

→ →

• ATOS 3D Digitizer (www.gom.com)Flexible optical measurement device Is based on Triangulation3D-Coordinaten are calculateda Polygon net of the surface is generated (STL)

ATOS II

Measurement and Radiographic Modelling of CAD-Surface Images

Page 44: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

44

Progress in Digital Radiology EwertApril 2007

Result: 3D CAD Model of a weld• STL of “BAM 3”

Modelling of a Scanned Weldment

top

root

Page 45: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

45

Progress in Digital Radiology EwertApril 2007

Pore Contrast Considering Measured Unsharpness and Noise for POD Calculation

0.0 0.5 1.0 1.5 2.0 2.5 3.0pore diameter [mm]

0

200

400

600

800

1000

max

imum

por

e co

ntra

st

â versus a from Simulation

max pore contrast (no noise)above (noise level = 30)center (noise level = 60)below (noise level = 90)decision threshold (SNR = 2.7)

Simulation of contrast function for copper welds of different thickness

Required for copper storage containers of the Swedish final repository of nuclear waste fuels

Measured with 9 MeV LINAC undBIR-line camera

Modelling BasedPOD

Page 46: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

46

Progress in Digital Radiology EwertApril 2007

0.0 0.5 1.0 1.5 2.0 2.5 3.0pore diameter [mm]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

PO

D m

ax c

ontra

st

Conservative POD Estimate from Simulation

SNR = 2.7POD (above)confidence boundPOD (center)confidence boundPOD (below)confidence bound

POD for Different Wall Thickness

Modelling BasedPOD

Page 47: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

47

Progress in Digital Radiology EwertApril 2007

Mobile CTin

Nuclear Power Plants and

in Aircraft Industry

Page 48: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

48

Progress in Digital Radiology EwertApril 2007

• Movement of X-ray tube parallel to pipe axis• Acquisition of few hundred projections• Reconstruction of cross sections

• Movement of X-ray tube parallel to pipe axis• Acquisition of few hundred projections• Reconstruction of cross sections

X-ray tube

Digital detector array

Planar Tomography – Reconstruction of Cross sections

Page 49: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

49

Progress in Digital Radiology EwertApril 2007

from outside to inside

3D-Reconstruction of Weldments Metallography

Planar Tomography

8

Certification byEuropeanNetworl ofInspection andQualification.

Page 50: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

50

Progress in Digital Radiology EwertApril 2007

Mobile TomosynthesisMobile Tomosynthesis

CT of Large ComponentsCT of Large Components

Page 51: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

51

Progress in Digital Radiology EwertApril 2007

Planar Tomography

Stringer Component from Aircraft

Page 52: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

52

Progress in Digital Radiology EwertApril 2007

Outside incorporated metal mesh

Central section in stringer

Inner surface with carbon fibre mesh

Impact

Page 53: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

53

Progress in Digital Radiology EwertApril 2007

Nano CT

Page 54: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

54

Progress in Digital Radiology EwertApril 2007

Berlin Electron Storage SYnchrotronBESSY

Double-MultilayerMono chromator, 5-70 keV7T WLS

asymmetricSi -Crystal,

Magnification 1: 50

CCD-Camera

rotatingSample

Storage ring

1 mm

3D-Nano-CT: Micro-driller, 19 keV, Worm holes, white refraction contrast,200 nm resolution

3D-Scatter CT: Ti/SiC-MMC, 39 keV,

light: crack contrast after fatigue

3D-CT-single cut

Gas turbine

Müller, Lange, Hentschel

Page 55: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

55

Progress in Digital Radiology EwertApril 2007

Motion Neutron Radiographywith Triggered Cycle

Page 56: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

56

Progress in Digital Radiology EwertApril 2007

BMW-Engine of running production with external electric control at ILL in Grenoble

T. Bücherl, B. Schillinger

Page 57: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

57

Progress in Digital Radiology EwertApril 2007

Oil cooling of pistons of running engine!

Oil at piston bottom

Oil ray is injected from downside to the piston

Valves(one after the other)

T. Bücherl, B. Schillinger

Page 58: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

58

Progress in Digital Radiology EwertApril 2007

Computed Radiography with Phosphor Imaging Plates is gaining more and more importance for mobile inspection and Film Replacement. New High Definition CR (HD CR) systems allow the CR application for Weld and Casting inspection with low energy X-rays. New calibration methods enable the High Contrast Sensitivity Technology(HCS RT) for radiographic inspection. The contrast sensitivity can be enhanced by a factor of 10 in comparison to film. New Digital Detector Arrays (DDA) are now available for stationary and mobile testing. They are also applied for automated defect recognition (ADR), CT, Back Scatter and Dual Energy Applications.Back Scatter Techniques are increasingly applied for Security and NDTNumeric Radiographic Modelling is applied for Experiment Planning, Film replacement, POD-calculations and trainingMobile and portable CT devices are suitable for non destructive cross sectioning in nuclear power industry and aircraft applicationsNeutron radiography at research reactors was enhanced for visualisation of motions

Summary:Summary:

Page 59: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

59

Progress in Digital Radiology EwertApril 2007

Acknowledgement

B. Redmer – BAM Berlin

U. Zscherpel – BAM Berlin

A. Alekseychuk – BAM Berlin

K. Bavendiek – Yxlon Hamburg

K. Osterloh – BAM Berlin

G.-R. Jaenisch – BAM Berlin

C. Bellon – BAM Berlin

M. Hentschel – BAM Berlin

A. Lange – BAM Berlin

J. Beckmann – BAM Berlin

Ch. Müller – BAM Berlin

S. Sood – CIT London

T. Bücherl – TUM Munich

B. Schillinger – TUM-Tech Munich

Page 60: Progress of Digital Industrial Radiology · Outside incorporated metal mesh Central section in stringer Inner surface with carbon fibre mesh Impact. 53 Progress in Digital Radiology

60

Progress in Digital Radiology EwertApril 2007

Ende

e-mail: [email protected]://www.bam.de

e-mail: [email protected]://www.bam.de

BAM-Berlin, Lab. VIII.3Unter den Eichen 8712005 BerlinTel. (030) 81041831FAX (030) 811 5089

BAM-Berlin, Lab. VIII.3Unter den Eichen 8712005 BerlinTel. (030) 81041831FAX (030) 811 5089

BAMmain building