Upload
dodien
View
218
Download
0
Embed Size (px)
Citation preview
16D5324-0008No.
Davis Partnership PC Arch2301 Blake St #100 Denver CO 80205-2108
TO:
01/14/2016DATE:
090000-FinishesRE:
Tina Du MONDATTN:
Shop Drawings
Letter
Prints
Change Order
Plans
Samples
Specifications / Product Data
Other:
Approval
Your Use
As Requested
Review and Comment
Attached
Separate Cover Via:
Approved as Submitted
Approved as Noted
Returned After Loan
Resubmit
Submit
Returned
Returned for Corrections
Due Date: 01/29/2016
WE ARE SENDING: SUBMITTED FOR:
SENT VIA:
ACTION TAKEN:
TRANSMITTAL
Juan MartinezSigned:
PROJECT: Centura Health-Avon Clinic Emergency Department
01/14/2016
Date
095113.01
Code
Acoustical Panel Ceilings /
Description
Architect Review
Status
JOB: 16D5324
CC:
Item
Submittal 090000
Package
1
Rev. Copies
Ph/Fax: 303-861-8555 303-861-3027
NOTES:
5995 Greenwood Plaza Blvd.Suite 100Greenwood Village, CO 80111-4710303-571-5377303-629-7467 (fax)
SUBMITTED
GH Phipps has reviewed and herbysubmits the attached in accordance withthe contract documents.
Note to Subcontractor/ Material Supplier:Subcontractor/ Material Supplier remains responsible for the confirmation and correlation of dimensions at the jobsite; fabrication processes and construction techniques; coordination of the work withthe work of other trades; and satisfactory performance of the work.
XDigitally Signed by Juan Martinez Jr.
LETTER OF TRANSMITTAL
DATE: JOB NO.:1/13/16 D5324-105ATTENTION:Blaine DodgionRE:Centura Avon Clinic
3367 S. Eliot StreetEnglewood, Co. 80110Phone 303-781-2829Fax 303-781-2838
Mailing Address:PO Box 27021Denver, Co. 80227
TOGH Phipps Construction5995 Greenwood Plaza, Suite 100Greenwood Village, CO 80111
WE ARE SENDING YOU Attached Under separate cover via the following items: Technical data Certifications SamplesShop drawings
MATERIAL SUBMITTED:
Acoustical CeilingsSpec Section 95113
ACP1Tile: 2x2 Ultima Health Zone #1935 Square Edge by ArmstrongGrid: Prelude 15/16" #7300, #7348, #7328 & #7800 by Armstrong
ACP2Tile: 2x2 Ultima #1912 Beveled Tegular Edge by ArmstrongGrid: Prelude 15/16" #7300, #7348, #7328 & #7800 by Armstrong
WDC1Woodworks Linear #6460W1NLC, 6" x 96" by ArmstrongGrid: Prelude 15/16" #7300, #7348, #7328 & #7800, Color: Black by Armstrong
VE ACP1Tile: 2x2 Symphony M RX #1222-RXS-1 by CertainteedGrid: #211-01, #1210-01, #1202-01 & #1420-01 by Chicago Metallic
VE ACP2Tile: 2x2 Symphony M #1222-IOF-1 by CertainteedGrid: #211-01, #1210-01, #1202-01 & #1420-01 by Chicago Metallic
Edge Profile
Susp. Dwg.Pgs. 273-277armstrong.com/ catdwgs
Item No.
Dimensions (Inches)
Acou
stic
s
Fire
R
atin
g Ligh
t
Ref
lect
Anti
-Mol
d &
Mild
ew
Sag
Re
sist
Ceri
fied
Low
VO
C Em
issi
ons
Dura
bilit
y
Prim
ary
(E
mbo
died
) En
ergy
Rec
ycle
d Co
nten
t◆
Rec
ycle
Pr
ogra
m
War
rant
y†
CAC
ULTIMA Health Zone UL Classified BioBlock+Humi-
Guard+Water Repel Wash Scrub Impact Scratch Soil
Below 11MJ/SF Yes
No. of Years
15/16" Square Lay-in
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Profiles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Profiles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
1, 6, 7 1935 24 x 24 x 3/4" 0.70 •
35 Class A
0.86 •
• • • • • • • • • • High • 30
1, 6, 7 1938** 24 x 48 x 3/4" 0.70 •
35 Class A
0.86 •
• • • • • • • • • • High • 30
15/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Profiles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Profiles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
15, 16 1937 24 x 24 x 3/4" 0.70 •
35 Class A
0.86 •
• • • • • • • • • • High • 30
9/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Profiles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Profiles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
29, 43, 47, 51, 55, 59
1936 24 x 24 x 3/4" 0.70 •
35 Class A
0.86 •
• • • • • • • • • • High • 30
** Item does not have painted edges
Ultima® Health Zone™
Square lay-in, tegularfine texture
Ultima Health Zone Square Lay-in with Prelude® 15/16" suspension system (Pg. 259)
TyPICAL APPLICATIONSClean Rooms (items 1935 & 1937) Healthcare• Patient rooms• Treatment rooms• Nurses' stations• Emergency rooms • Corridors• Lavatories and restrooms• Kitchen/food prep areas
KEy SELECTION ATTRIbUTES• Clean Rooms up to ISO Class 5 (Class 100)
(items 1935 & 1937)• Exceeds FGI Guidelines for acoustics and
cleanablility in general healthcare spaces• Meets USDA/FSIS guidelines for use in food
processing areas• Long-lasting water-repellency;
Washable and Scrubbable• Smooth, clean, durable finish – Impact-,
Scratch-, and Soil-resistant; safe for use with disinfectants
• Excellent sound absorption• 30-Year Limited System Warranty
against visible sag, mold/mildew, and bacterial growth
Ultima® Health Zone™
Square lay-in, tegularfine texture
COLOR
White
VISUAL SELECTION PERFORMANCE Dots represent high level of performance.
SUSPENSION SySTEMS15/16"
15/16" Flush TegularLedges
4.B.
Prelude Clean Room™ (Steel or Aluminum)
Prelude
AL Prelude Plus XL®
SS Prelude Plus XL
Clean Room™ (Steel or Aluminum)
9/16"
Suprafine® Silhouette® XL 1/4" Reveal
Silhouette® XL 1/8" Reveal
Interlude® XL Sonata® XL Trimlok®
88%
min
era
l Fi
ber
$$ $$
rene
wab
le
mat
eria
ls
71% RECYCLED CONTENTUp
to EPD
a v a i l a b l e
Calculate LEED contribution at armstrong.com/greengenie *LOCATION DEPENDENT
leeD®
For select items only
acou
stic
s
ener
gy
dayl
ight
&
view
s
recy
cled
co
nten
t
was
te
mgm
t
loca
l*
mat
eria
ls
indo
or a
ir qu
ality
Create! colors available on item 1935. See pages 165-167.
Ultima® Health Zone™
Square lay-in, tegularfine texture
Ultima® Health Zone™
Square lay-in, tegularfine texture
88%
$$ $$
rene
wab
le
mat
eria
ls
71% RECYCLED CONTENTUp
to EPD
a v a i l a b l e
Calculate LEED contribution at armstrong.com/greengenie *LOCATION DEPENDENT
leeD®
For select items only
acou
stic
s
ener
gy
dayl
ight
&
view
s
recy
cled
co
nten
t
was
te
mgm
t
loca
l*
mat
eria
ls
indo
or a
ir qu
ality
MaterialWet-formed mineral fiber with DuraBrite® acoustically transparent water-repellent membrane.
Surface FinishDuraBrite with factory-applied latex paint
Fire PerformanceASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less. Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 Classification Type IV, Form 2, Pattern E Fire Class A
Sag ResistanceHumiGuard® Plus – superior resistance to sagging in high humidity conditions up to, but not including, standing water and outdoor applications.
Anti-Mold/Mildew & bacteriaBioBlock® Plus contains an anti-microbial treatment and provides guaranteed resistance against growth of mold/mildew and Gram-positive and Gram-negative odor/stain-causing bacteria for 30 years.
VOC Emissions Third party certified compliant with California Department of Public Health CDPH/EHLB/Standard Method Version 1.1, 2010. This standard is the guideline for low emissions in LEED, CalGreen Title 24, ANSI/ASHRAE/USGBC/IES Standard 189; ANSI/GBI Green Building Assessment Protocol.
Primary (Embodied) Energy See all LCA information on our EPD’s.
High Recycled Content ◆Contains greater than 50% total recycled content. Total recycled content based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines.
Insulation ValueR Factor – 2.2 (BTU units) R Factor – 0.39 (Watts units)
30-year Performance Guarantee & Warranty†
When installed with Armstrong Suspension System. Details at armstrong.com/warranty
Cleaning RecommendationsTo clean panel, use a clean, white cloth with water or a mild detergent and wipe surface. To disinfect panel, lightly spray surface and wipe clean with a clean, white cloth. Acceptable colorless disinfectants include: • Sodium hypochlorite • Hydrogen peroxide • Quaternary ammonium
Weight; Square Feet/Carton1.08 lbs/SF; 48 SF/ctn
Minimum Order Quantity1 carton
PHySICAL DATA
min
era
l Fiber
LEED® is a registered trademark of the U.S. Green Building Council All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates © 2013 AWI Licensing Company Printed in the United States of America
techLineSM / 1 877 ARMSTRONG armstrong.com/commceilings
(search: ultima) BPCS-4066-513
K e y S e l e c t i o n A t t r i b u t e s
• Seismic Rx® SuspensionSystem saves time and money;ICC-ES approach to installations(ESR-1308)
• PeakForm® patented profileincreases strength andstability for improvedperformance duringinstallation
• SuperLock™2 main beam clipis engineered for a strong,secure connection and fastaccurate alignment confirmedwith an audible click; easy toremove and relocate
• Hot dipped galvanized coatinginhibits red rusting better thanelectrogalvanized or paintedsystems
• Rotary-stitched duringmanufacture by a patentedmethod for additional torsionalstrength and extra stabilityduring installation
• XL2 staked-on stab end detailprovides tight, secure lockedconnection; easy to remove, reuse and relocate
• State-of-the-art expansion reliefon Fire Guard™ options;provides greater strength andprohibits distortion of grid faceduring installation
• 10-year limited warranty; 30-year with HumiGuard® Plus
Ty p i c a l A p p l i c a t i o n s
• Retail
• Education
• Offices
• Hospitality
• Fire Guard applications basedon building construction andlocal fire code requirements
P r o d u c t D e s c r i p t i o n
B. Components:1. Main Beams: Double-web
construction, web height 1-11/16″with peaked roof top bulb and15/16″ bottom flange withprefinished steel or aluminumcapping*; one fire expansion reliefper fire rated main beam.
* NOTE: Fire Guard items available insteel capping only.
2A. Cross Tee: Double-web construction,web height 1-11/16″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2B. Cross Tee: Double-web construction,web height 1-1/2″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2C. Cross Tee: Double-web construction,web height 1-3/8″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2D. Cross Tee: Double-web construction,web height 1-3/16″, 15/16″ bottomflange with prefinished steel cap andoverride at each end. Staked-on enddetail allows easy cross tee removaland remounting.
Wall Moldings:3A. Angle molding: hemmed with
prefinished exposed flanges
3B. Shadow molding: hemmed withprefinished exposed flanges
3C. Shadow Molding: (Compatible with Seismic Rx® and BERC 2)
3D. Channel molding: hemmed withprefinished exposed flanges
■■ 7300 (144″, routs 6″ OC, Intermediate-duty)■■ 7301 (144″, routs 6″ OC, Heavy-duty)■■ 7302 (120″, routs 6″ OC, Intermediate-duty)■■ 7305 (140″, routs 10″ OC, Intermediate-duty)■■ 734032 (3600mm, routs 150mm OC, Intermediate-duty)Fire Guard Items■■ 8300 (144″, routs 6″ OC, Intermediate-duty)■■ 8301 (144″, routs 6″ OC, Heavy-duty)■■ 834033 (3600mm, routs 150mm OC,
Intermediate-duty)■■ Other
■■ XL7340 (48″, routs 12″ OC)■■ XL7341 (48″, routs 12″ OC)■■ XL7330 (36″)■■ XL7380 (96″, routs 12″ OC)■■ XL7357 (60″, routs 6″ OC)■■ XL7358 (60″, routs 20″ OC)■■ XL7390 (72″, routs 12″ OC)Fire Guard Items■■ XL8320 (24″)■■ XL8340 (48″, routs 12 ″ OC)■■ XL8341 (48″, routs 12 ″ OC)■■ 833033 (1200mm, routs 300mm OC)■■ Other
■■ XL7342 (48″, routs 12″ OC)
■■ XL7318 (12″)■■ XL7368 (20″)■■ XL7328 (24″)■■ XL7378 (30″)■■ XL7348 (48″)■■ 312451 (300mm, center rout)■■ 312051 (600mm)■■ 313051 (1200mm, center rout)Fire Guard Items■■ XL8323 (24″)■■ 832052 (600mm)■■ Other
■■ XL7148 (48″, routs 12 ″ OC)■■ XL7128 (24″)
Materials
A. General: ASTM C635 (Intermediate-duty) (Heavy-duty) main beam classification, commercial-quality hot dipped galvanized steel. Exposedsurfaces chemically cleansed, galvanized steel or aluminum capping prefinished in baked polyester paint or annodized.
1/4"(6mm)
3/32"(2mm) 1-3/16"
(30mm)
15/16"(24mm)
1/4"(6mm)
1-3/8"(35mm)
15/16"(24mm)
1-11/16"(43mm)
9/16" (14mm)
1/4"
15/16"(24mm)
(6mm)
2C.
2D.
1/4" (6mm)1/4" (6mm)
1-11/16" (43mm)
1-1/2" (38mm)
15/16" (24mm)
15/16" (24mm)
(A) (B) Item # Length Flange Height■■ 7800 144″ 7/8″ 7/8″■■ 7807 120″ 2″ 1″■■ 7808 120″ 2″ 2″■■ HD7801 120″ 7/8″ 7/8″
(A) (B) (C)Item # Length Flange Height Reveal■■ 7875 120″ 3/4″ 15/16″ 1/2″
■■ 7877 120″ 15/16″ 15/16″ 1/4″■■ 7878 120″ 15/16″ 15/16″ 3/8″■■ 7897 120″ 15/16″ 15/16″ 1/2″
(A) (B) (C) Item # Length Flange Height Flange■■ 7835 120″ 7/8″ 1-3/4″ 9/16″
B
A
B
A
C
A
B
C
15/16" Exposed Tee System
PRELUDE® XL®RecycledContent: 30%
C o l o r S e l e c t i o n
■■ WH - White ■■ CR - Cream■■ HA - Haze ■■ VA - Vanilla†
■■ CM - Camel■■ YS - Oyster†
■■ PL - Platinum ■■ AD - Adobe†
■■ AR - Brass ■■ AM - Mirror ■■ BL - Tech Black ■■ SG - Silver Grey■■ MY - Gun Metal Grey
■■ ST - Slate■■ WK - Wolf†
■■ WA - White Aluminum
■■ NA - Natural Aluminum
■■ SA - Silver Satin■■ HDC - Hot Dipped
Clear Coat ■■ PW - Pewter†
■■ BZ - Bronze†
■■ SL - Silver†
† Only available on 7301, XL7342, XL7328, and 7800NOTE: Color chips included with samples of Armstrong grid.See your Armstrong representative for sample material.NOTE: Items 7305, 7302, XL7340, XL7380, XL7357,XL7358, XL7128, XL7148, XL7348, XL7330, XL7318,XL7368, XL7378, XL7390, XL8320, XL8341, XL7341 are available in white only. NOTE: 8300, XL8340 and XL8323 are available in whiteand black only.
3344 Prelude XL_610 7/9/10 3:26 PM Page 1
MaterialHot dipped galvanized steel
Surface FinishBaked polyester paint or anodized
Face Dimension15/16″
ProfileExposed tee
Cross Tee/Main Beam InterfaceOverride
End DetailMain Beam: Staked-on clipXL Cross Tee: Staked-on clip
Duty ClassificationIntermediate or Heavy-duty
Main Beam Load Test DataHANGER SPACING
MAIN WEB ASTM Lbs./LF. (Simple Span)**BEAMS LENGTH HEIGHT CLASS 4′ 5′7300 144″ 1-11/16″ Intermediate-duty 12.8 6.357301 144″ 1-11/16″ Heavy-duty 16.5 8.73
734032 144″ 1-11/16″ Intermediate-duty 12.8 6.358300/834033 144″ 1-11/16″ Intermediate-duty 12.8 6.35
8301 144″ 1-11/16″ Heavy-duty 16.5 8.737302 120″ 1-11/16″ Intermediate-duty 12.8 6.357305 140″ 1-11/16″ Intermediate-duty 12.8 6.35
Cross Tee Load Test DataHANGER SPACING
CROSS WEB Lbs./LF. (Simple Span)**TEES LENGTH HEIGHT 4′
XL7318/312451 12″ 1-3/8″ 40.45XL7368 20″ 1-3/8″ 40.45XL7128 24″ 1-3/16″ 33.0
XL7328/312051 24″ 1-3/8″ 40.45XL8323/832052 24″ 1-3/8″ 40.45
XL8320 24″ 1-11/16″ 61.33XL7378 30″ 1-3/8″ 16.54XL7330 36″ 1-11/16″ 23.11XL7148 48″ 1-3/16″ 6.0
XL8340/833033/ 48″ 1-11/16″ 12.25XL7340
XL7341/XL8341 48″ 1-1/2″ 16.59XL7342 48″ 1-1/2″ 9.00
XL7348/313051 48″ 1-3/8″ 8.31XL7357 60″ 1-11/16″ 7.61XL7358 60″ 1-11/16″ 7.61XL7380 96″ 1-11/16″ 12.12XL7390 72″ 1-11/16″ 12.23
Seismic PerformanceMINIMUM LBS. TO PULL OUT
MAIN BEAMS COMPRESSION/TENSION7300, 7302, 7305, 335.0734032, 8300
7301, 8301 330.0
MINIMUM LBS. TO PULL OUTCROSS TEES COMPRESSION/TENSION
All XL cross tees exceed 300 lbs. in both compression and tension.
ICC ReportsFor areas under ICC jurisdiction, see ICC evaluation report number 1308 for allowablevalues and/or conditions of use concerning the suspension system components listed onthis page. The report is subject to reexamination, revisions and possible cancellation.**To derive maximum lbs/SF, divide the on-center spacing of the component into the lbs/LF given in the
load test data table.
P h y s i c a l D a t a M a x i m u m F i x t u r e W e i g h t
LIGHT FIXTUREB. Cross Tee to Cross Tee
LIGHT FIXTUREA. Main Beam to
Main Beam
Main Beam ▲
Hanger Wire (•)
Main beams ▲
Hanger Wire (•)
1. Fixture* 24″ x 48″ 24″ x 24″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item XL8340/XL7340 69.27 lbs. 80.55 lbs.4. Item XL7342 40.89 lbs. 52.26 lbs.5. Item XL8341/XL7341 81.67 lbs. 100.0 lbs.
1. Fixture* 24″ x 48″ 12″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item XL8340/XL7340 49.27 lbs. 42.17 lbs.5. Item XL8341/XL7341 72.32 lbs. 63.32 lbs.
*Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is based on single fixtureonly. For end-to-end fixtures or other configurations not shown, consult your Armstrong representative.
NOTE: The above data is based on 48″ hanger wire spacing, board weight of 1 lb./SF, maximum deflection of teesnot to exceed 1/360 of the span, and suspension system installed in accordance with ASTM C636.
1. Fixture* 24″ x 48″ 24″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item 7300/8300 69.27 lbs. 49.27 lbs.
7302Item 7301/8301 100.0 lbs. 72.32 lbs.
1. Fixture* 12″ x 48″ 12″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item 7300/8300 54.26 lbs. 47.17 lbs.
7302Item 7301/8301 100.0 lbs. 63.32 lbs.
1. Fixture* 24″ x 48″ 20″ x 60″2. Planning Module 60″ x 60″ 60″ x 60″3. Hanger Spacing 48″ 48″4. Item 7300/8300 56.47 lbs. 43.21 lbs.
7305Item 7301/8301 56.47 lbs. 65.46 lbs.
Main Beams tested as follows: 7300 tested at 13.0 lbs./LF to 1/360 of 4′ span; 7301 tested at 16.5 lbs./LF to1/360 of 4′ span.
•••
• •••
••
•••
• •
••
• •
••
•••
• •••
•
• •
••
• •
••
•••
•
TechLineSM / 1 877 ARMSTRONG1 877 276 7876
armstrong.com/ceilingsCS-3344-710
All trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2010 AWI Licensing Company • Printed in the United States of America
15/16" Exposed Tee System
PRELUDE® XL®
3344 Prelude XL_610 7/9/10 3:26 PM Page 2
1. Ultima Beveled Tegular
2. Ultima with Suprafin ® 9/16" suspension system
3. Ultima with Silhouette® XL® 9/16" suspension system with 1/4" reveal
TYPICAL APPLICATIONS• Offices – closed spaces for privacy
and confidentiality; open spaces for focus, collaboration, and teaming
• Healthcare – assists in addressing HIPAA, HCAHPS, and FGI acoustical requirements
• Classrooms• Corridors• Lobbies/reception areas• Department stores/retail
KEY SELECTION ATTRIBUTES• Smooth, clean, durable finish –
Washable, Impact-resistant, Scratch-resistant, Soil-resistant
• Excellent sound absorption• High CAC for excellent sound
blocking – items 1894, 1895, 1951, 1952
• Ceiling-2-Ceiling™ Post-consumer Recycled Content options: items 1911HRC, 1912HRC, 1914HRC, 1915HRC. 71% Pre-consumer; 15% Post-consumer
• USDA Certified Biobased Product – 88%
• Available with AirGuard™ Coating• Visual coordinates with Optima® for
mixed (open/closed plan) applications• Item 1912 available with Create!™
printed images and patterns – see pages 175-177
• Non-directional visual reduces scrap and installation time
• Compatible with the TechZone® Ceiling Systems
• 30-Year Limited System Warranty against visible sag (excludes items 1905 and 1929), mold, and mildew.
DETAILS (Other Suspension Systems compatible. Refer to listing on page 236.)
COLOR
White
235
Ultima® Beveled Tegular panels with Sonata® 9/16" suspension system (Pg. 289)
A smooth visual ceiling with Total Acoustics™ performance, sound absorption and blocking, needed for today’s flexible spaces
Ultim
aUl
tima
Hig
h N
RCULTIMA® ULTIMA® High NRCTegularfine texture
See more photos at: armstrong.com/photogallerySEARCH: ultima
friendlycloud
2 31
TechLineSM 877 ARMSTRONG
armstrong.com/commceilings
1910, 1913
Edge Profile
Susp. Dwg.Pgs. 295-299armstrong.com/ catdwgs
Item No.
Dimensions (Inches)
UL Classified Acoustics To
tal
Acou
stic
s1
Fire
Ra
ting Ligh
t Re
flect
Anti-
Mol
d &
Mild
ew
Sag
Resi
st
Cert
ified
Low
VO
C Em
issi
ons
Was
h
Impa
ct
Scra
tch
Soil
Recy
cled
Co
nten
t
Recy
cle
Prog
ram
30-Y
r W
arra
nty
+ =
ULTIMA® High NRCBio-
BlockHumi-
Guard+ Durability
15/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
15 1941 24 x 24 x 1" 0.80 •
35 •
Class A
0.87 •
• • • • • • • • • •
15 1944 24 x 48 x 1" 0.80 •
35 •
Class A
0.87 •
• • • • • • • • • •
15 Other Size Panels
W: 12" – 24" / L: 24" – 60" 1" Thick
N/A N/A Class A
0.87 •
• • • • • • • • • •
9/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
29, 44, 48, 52, 56, 60
1942 24 x 24 x 1" 0.80 •
35* •
Class A
0.87 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1942HRC 24 x 24 x 3/4" 0.75 •
35 •
Class A
0.87 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1945 24 x 48 x 1" 0.80 •
35* •
Class A
0.87 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
Other Size Panels
W: 12" – 24" / L: 24" – 48" 1" Thick
N/A N/A Class A
0.87 •
• • • • • • • • • •
ULTIMA®
15/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
15 1422 6 x 48 x 3/4" N/A N/A – Class A
0.90 •
• • • • • • • • • •
15 1917 12 x 24 x 3/4" N/A N/A – Class A
0.90 •
• • • • • • • • • •
15 1993 12 x 48 x 3/4" N/A N/A – Class A
0.90 •
• • • • • • • • • •
1 Total Acoustics™ ceiling panels have an ideal combination of noise reduction and sound-blocking performance in one product. HRC items not available in other size panels.
VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance.
236
Insulation ValueR Factor – 2.2 (BTU units) R Factor – 0.39 (Watts units)
30-Year Performance Guarantee & WarrantyWhen installed with Armstrong® Suspension System. Details at armstrong.com/warranty
Weight; Square Feet/Carton 1917, 1993 – 1.05 lbs/SF; 24 SF/ctn 1945 – 1.14 lbs/SF; 40 SF/ctn 1941, 1942 – 1.125 lbs/SF; 40 SF/ctn 1944 – 1.125 lbs/SF; 40 SF/ctn 1422 – 1.08 lbs/SF; 24 SF/ctn
Minimum Order Quantity1 carton, excludes other size panels
Metric Items Available1917M, 1951M – Metric items are subject to extended lead times and minimum quantities. Contact your representative for more details.
PHYSICAL DATAMaterialWet-formed mineral fiber with DuraBrite® acoustically transparent membrane.
Surface FinishDuraBrite scrim with factory-applied latex paint
Fire PerformanceASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less. Smoke Developed Index 50 or less (UL labeled.) Fire Guard™: A fire-resistive ceiling when used in applicable UL assemblies
ASTM E1264 Classification Type IV, Form 2, Pattern E Fire Class A
Humidity/Sag ResistanceHumiGuard® Plus ceiling panels maintain superior sag resistance. Recommended for areas subject to high humidity, up to, but not including, standing water and outdoor applications. (Excludes items 1905 and 1929).
Anti-Mold/MildewCeiling panels with BioBlock® coating contain a mold-inhibiting agent that resists the growth of mold and mildew.
VOC Emissions Third-party certified compliant with California Department of Public Health CDPH/EHLB/Standard Method Version 1.1, 2010. This standard is the guideline for low emissions in LEED, CalGreen Title 24, ANSI/ASHRAE/USGBC/IES Standard 189; ANSI/GBI Green Building Assessment Protocol.
Primary (Embodied) Energy See all LCA information on our EPD’s.
High Recycled ContentContains greater than 50% total recycled content. Total recycled content based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines.
ULTIMA® ULTIMA® High NRCTegularfine texture
88%
SUSPENSION SYSTEMS15/16" 9/16"
Prelude® Silhouette® 1/4" Reveal
Silhouette 1/8" Reveal
Suprafine® Interlude® XL® HRC
Sonata® XL® Trimlok®
Blizzard White – Suspension System FinishA color and texture coordinated suspension system to complement Ultima ceiling panels for a monolithic look and feel.
new* CAC reduced two points on these suspension systems
MIN
ERA
L FIBER
▲
LOCATION DEPENDENT
RECYCLED CONTENT
LEED®
ener
gy
man
agem
ent
recy
clab
le/
exte
nded
pr
oduc
er r
esp.
mat
eria
l in
gred
ient
re
port
ing
recy
cled
co
nten
tso
urci
ng o
f ra
w m
ater
ials
low
em
ittin
g/
mat
eria
ls
light
ing
qu
alit
y
biob
ased
m
ater
ials
regi
onal
m
ater
ials
desi
gn fo
r fle
xibi
lity
cons
truc
tion
was
te m
gmt
EPD
acou
stic
s
Calculate LEED contribution at armstrong.com/greengenie76%U
P TO
TechLineSM 877 ARMSTRONG
armstrong.com/commceilings
$$$$
HRC items contain 15% or greater post-consumer
recycled ceilings
–
–
VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. $$$$
Edge Profile
Susp. Dwg.Pgs. 295-299armstrong.com/ catdwgs
Item No.
Dimensions (Inches)
UL Classified Acoustics To
tal
Acou
stic
s1
Fire
Ra
ting
Ligh
t Re
flect
Anti-
Mol
d &
Mild
ew
Sag
Resi
st
Cert
ified
Low
VO
C Em
issi
ons
Was
h
Impa
ct
Scra
tch
Soil
Recy
cled
Co
nten
t
Recy
cle
Prog
ram
30-Y
r W
arra
nty
+ =
ULTIMA®Bio-
BlockHumi-
Guard+ Durability
15/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
15 1994 12 x 60 x 3/4" N/A N/A – Class A
0.90 •
• • • • • • • • • •
15 1995 12 x 72 x 3/4" N/A N/A – Class A
0.90 •
• • • • • • • • • •
15 1911 1911HRC
24 x 24 x 3/4" 24 x 24 x 3/4"
0.70 •
35 •
Class A
0.90 •
• • • • • • • • •
• •
15 1951 24 x 24 x 3/4" 0.60 40 •
Class A
0.90 •
• • • • • • • • • •
15 1894 24 x 24 x 3/4" 0.60 40 •
Fire Guard™
0.90 •
• • • • • • • • • •
15 1914 1914HRC
24 x 48 x 3/4" 24 x 48 x 3/4"
0.70 •
35 •
Class A
0.90 •
• • • • • • • • •
• •
15 1985 24 x 60 x 3/4" 0.70•
35 •
Class A
0.90 •
• • • • • • • • • •
15 1981 24 x 72 x 3/4" 0.70•
35 •
Class A
0.90 •
• • • • • • • • • •
15 FastSize™ Panels
W: 4" - 24" / L: 4" - 72" 3/4" thick
N/A N/A – Class A
0.90 •
• • • • • • • • • •
9/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
29, 44, 48, 52, 56, 60
1423 6 x 48 x 3/4" 0.70
•35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1427 6 x 60 x 3/4" 0.70
•35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1916 12 x 24 x 3/4" N/A 35 •
– Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1996 12 x 48 x 3/4" 0.65 35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1997 12 x 60 x 3/4" 0.65 35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1998 12 x 72 x 3/4" 0.65 35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1912 1912HRC
24 x 24 x 3/4" 24 x 24 x 3/4"
0.70 •
35 •
Class A
0.90 •
• • • • • • • • •
• •
29, 44, 48, 52, 56, 60
1952 24 x 24 x 3/4" 0.60 40* •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1895 24 x 24 x 3/4" 0.60 40* •
Fire Guard
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1915 1915HRC
24 x 48 x 3/4" 24 x 48 x 3/4"
0.70 •
35 Class A
0.90 •
• • • • • • • • •
• •
1 Total Acoustics™ ceiling panels have an ideal combination of noise reduction and sound-blocking performance in one product. HRC items not available in other size panels.
237
ULTIMA® ULTIMA® High NRCTegularfine texture
88%
MIN
ERA
L FI
BER
▲
LOCATION DEPENDENT
RECYCLED CONTENT
LEED®
ener
gy
man
agem
ent
recy
clab
le/
exte
nded
pr
oduc
er r
esp.
mat
eria
l in
gred
ient
re
port
ing
recy
cled
co
nten
tso
urci
ng o
f ra
w m
ater
ials
low
em
i ttin
g/
mat
eria
ls
light
ing
qu
alit
y
biob
ased
m
ater
ials
regi
onal
m
ater
ials
desi
gn fo
r fle
xibi
lity
cons
truc
tion
was
te m
gmt
EPD
acou
stic
s
Calculate LEED contribution at armstrong.com/greengenie76%U
P TO
TechLineSM 877 ARMSTRONG
armstrong.com/commceilings
HRC items contain 15% or greater post-consumer
recycled ceilings
FastSize: Factory-finished made-to-order sizes, shipped fast (1 carton min.)
VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance.
Edge Profile
Susp. Dwg.Pgs. 295-299armstrong.com/ catdwgs
Item No.
Dimensions (Inches)
UL Classified Acoustics To
tal
Acou
stic
s1
Fire
Ra
ting
Ligh
t Re
flect
Anti-
Mol
d &
Mild
ew
Sag
Resi
st
Cert
ified
Low
VO
C Em
issi
ons
Was
h
Impa
ct
Scra
tch
Soil
Recy
cled
Co
nten
t
Recy
cle
Prog
ram
30-Y
r W
arra
nty
+ =
ULTIMA®Bio-
BlockHumi-
Guard+ Durability
9/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
29, 44, 48, 52, 56, 60
1986 24 x 60 x 3/4" 0.70 •
35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1982 24 x 72 x 3/4" 0.70 •
35 •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1905 30 x 30 x 3/4" 0.70 •
35 •
Class A
0.90 •
• Std • • • • • • • •
29, 44, 48, 52, 56, 60
1929 30 x 54 x 3/4" 0.70 •
35 •
Class A
0.90 •
• Std • • • • • • • •
29, 44, 48, 52, 56, 60
FastSize™ Panels
W: 4" - 24" / L: 4" - 72" 3/4" Thick
N/A N/A Class A
0.90 •
• • • • • • • • • •
ULTIMA® with AirGuard™ Coating
15/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
15 1901 24 x 24 x 3/4" 0.70 •
35 •
Class A
0.90 •
• • • • • • • • • •
15 1904 24 x 48 x 3/4" 0.70 •
35 •
Class A
0.90 •
• • • • • • • • • •
9/16" Beveled Tegular
Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapK2C2 Short
15/16" Chamford TegularCirrus Proÿles Chamfered
Tongue and GrooveConcealed Beveled K4C4
Classic Step Tegular Ultima Plank ShipLapLong Edge Detail
Ultima Plank ShipLapBeveled Tegular Short
15/16 Classic Step Tegular~8-ID (99) (drw 10)
9/16" Beveled Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular 15/16" Square Tegular
9/16" Chamfered TegularCirrus Proÿles Chamfered
Concealed Soft Look Radiused Tegular
9/16" Cubic Graphis NeoCubic
9/16" Flush TegularLedges
15/16" Flush TegularLedges
9/16" Wrapped TegularGraphis Wrapped Linear
and Cubic
9/16" Wrapped Linear and Mixed Corner “B”
(Flumes, Graphis Linear Corner & Dots & Squares)
Concealed Square Edge K4C4
Linear Cubic Beveled Crossgate
A B15/16" Vector
C D15/16" Vector C & D
A B C D
29, 44, 48, 52, 56, 60
1902 24 x 24 x 3/4" 0.70 •
35* •
Class A
0.90 •
• • • • • • • • • •
29, 44, 48, 52, 56, 60
1906 24 x 48 x 3/4" 0.70 •
35 •
Class A
0.90 •
• • • • • • • • • •
1 Total Acoustics™ ceiling panels have an ideal combination of noise reduction and sound-blocking performance in one product. HRC items not available in other size panels.
238
ULTIMA® ULTIMA® High NRCTegularfine texture
Weight; Square Feet/Carton1905 – 1.05 lbs/SF; 62.5 SF/ctn 1911, 1912, 1914, 1915 – 1.05 lbs/SF; 48 SF/ctn 1916, 1996 – 1.05 lbs/SF; 24 SF/ctn 1423 – 1.08 lbs/SF; 24 SF/ctn 1427 – 1.07 lbs/SF; 24 SF/ctn 1929 – 1.02 lbs/SF; 68 SF/ctn 1895, 1952, 1951 – 1.31 lbs/SF; 48 SF/ctn 1901, 1902, 1904, 1906 – 1.08 lbs/SF; 48 SF/ctn 1997, 1994 – 1.05 lbs/SF; 30 SF/ctn 1998, 1995 – 1.05 lbs/SF; 36 SF/ctn1981, 1982 - 1.08 lbs/SF; 72 SF/ctn1894, 1985, 1986 – 1.08 lbs/SF; 80 SF/ctn
Minimum Order Quantity1 carton
Metric Items Available1905M, 1912M, 1912MHRC, 1914M, 1915M, 1916M, 1941M, 1944M, 1945M – Metric items are subject to extended lead times and minimum quantities. Contact your representative for more details.
PHYSICAL DATAMaterialWet-formed mineral fiber with DuraBrite® acoustically transparent membrane.
Surface FinishDuraBrite with factory-applied latex paint
Fire PerformanceASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less. Smoke Developed Index 50 or less (UL labeled.) Fire Guard™: A fire-resistive ceiling when used in applicable UL assemblies
ASTM E1264 Classification Type IV, Form 2, Pattern E Fire Class A
Humidity/Sag ResistanceHumiGuard® Plus ceiling panels maintain superior sag resistance. Recommended for areas subject to high humidity, up to, but not including, standing water and outdoor applications. (Excludes items 1905 and 1929).
Anti-Mold/Mildew & BacteriaCeiling panels with BioBlock® coating contain a mold-inhibiting agent that resists the growth of mold and mildew.
VOC Emissions Third-party certified compliant with California Department of Public Health CDPH/EHLB/Standard Method Version 1.1, 2010. This standard is the guideline for low emissions in LEED, CalGreen Title 24, ANSI/ASHRAE/USGBC/IES Standard 189; ANSI/GBI Green Building Assessment Protocol.
Primary (Embodied) Energy See all LCA information on our EPD’s.
High Recycled ContentContains greater than 50% total recycled content. Total recycled content based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines.
Insulation ValueR Factor – 2.2 (BTU units) R Factor – 0.39 (Watts units)
30-Year Performance Guarantee & WarrantyWhen installed with Armstrong® Suspension System. Details at armstrong.com/warranty
SUSPENSION SYSTEMS 9/16"
Silhouette®
1/4" Reveal Silhouette
1/8" Reveal Suprafine® Interlude® XL® HRC Sonata® XL® Trimlok®
* CAC reduced two points on these suspension systemsBlizzard White – Suspension System FinishA color and texture coordinated suspension system to complement Ultima ceiling panels for a monolithic look and feel.
new
88%
MIN
ERA
L FIBER
LEED® is a registered trademark of the U.S. Green Building Council All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates © 2015 AWI Licensing Company Printed in the United States of America
TechLineSM / 1 877 ARMSTRONG armstrong.com/commceilings
(search: ultima)
HRC items contain 15% or greater post-consumer
recycled ceilings▲
LOCATION DEPENDENT
RECYCLED CONTENT
LEED®
ener
gy
man
agem
ent
recy
clab
le/
exte
nded
pr
oduc
er r
esp.
mat
eria
l in
g red
ient
re
port
ing
recy
cled
co
nten
tso
urci
ng o
f ra
w m
ater
ials
low
em
ittin
g/
mat
eria
ls
light
ing
qu
alit
y
biob
ased
m
ater
ials
regi
onal
m
ater
ials
desi
gn fo
r fle
xibi
lity
cons
truc
tion
was
te m
gmt
EPD
acou
stic
s
Calculate LEED contribution at armstrong.com/greengenie76%U
P TO
$$$$
FastSize: Factory-finished made-to-order sizes, shipped fast (1 carton min.)
BPCS-3039-615
–
K e y S e l e c t i o n A t t r i b u t e s
• Seismic Rx® SuspensionSystem saves time and money;ICC-ES approach to installations(ESR-1308)
• PeakForm® patented profileincreases strength andstability for improvedperformance duringinstallation
• SuperLock™2 main beam clipis engineered for a strong,secure connection and fastaccurate alignment confirmedwith an audible click; easy toremove and relocate
• Hot dipped galvanized coatinginhibits red rusting better thanelectrogalvanized or paintedsystems
• Rotary-stitched duringmanufacture by a patentedmethod for additional torsionalstrength and extra stabilityduring installation
• XL2 staked-on stab end detailprovides tight, secure lockedconnection; easy to remove, reuse and relocate
• State-of-the-art expansion reliefon Fire Guard™ options;provides greater strength andprohibits distortion of grid faceduring installation
• 10-year limited warranty; 30-year with HumiGuard® Plus
Ty p i c a l A p p l i c a t i o n s
• Retail
• Education
• Offices
• Hospitality
• Fire Guard applications basedon building construction andlocal fire code requirements
P r o d u c t D e s c r i p t i o n
B. Components:1. Main Beams: Double-web
construction, web height 1-11/16″with peaked roof top bulb and15/16″ bottom flange withprefinished steel or aluminumcapping*; one fire expansion reliefper fire rated main beam.
* NOTE: Fire Guard items available insteel capping only.
2A. Cross Tee: Double-web construction,web height 1-11/16″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2B. Cross Tee: Double-web construction,web height 1-1/2″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2C. Cross Tee: Double-web construction,web height 1-3/8″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2D. Cross Tee: Double-web construction,web height 1-3/16″, 15/16″ bottomflange with prefinished steel cap andoverride at each end. Staked-on enddetail allows easy cross tee removaland remounting.
Wall Moldings:3A. Angle molding: hemmed with
prefinished exposed flanges
3B. Shadow molding: hemmed withprefinished exposed flanges
3C. Shadow Molding: (Compatible with Seismic Rx® and BERC 2)
3D. Channel molding: hemmed withprefinished exposed flanges
■■ 7300 (144″, routs 6″ OC, Intermediate-duty)■■ 7301 (144″, routs 6″ OC, Heavy-duty)■■ 7302 (120″, routs 6″ OC, Intermediate-duty)■■ 7305 (140″, routs 10″ OC, Intermediate-duty)■■ 734032 (3600mm, routs 150mm OC, Intermediate-duty)Fire Guard Items■■ 8300 (144″, routs 6″ OC, Intermediate-duty)■■ 8301 (144″, routs 6″ OC, Heavy-duty)■■ 834033 (3600mm, routs 150mm OC,
Intermediate-duty)■■ Other
■■ XL7340 (48″, routs 12″ OC)■■ XL7341 (48″, routs 12″ OC)■■ XL7330 (36″)■■ XL7380 (96″, routs 12″ OC)■■ XL7357 (60″, routs 6″ OC)■■ XL7358 (60″, routs 20″ OC)■■ XL7390 (72″, routs 12″ OC)Fire Guard Items■■ XL8320 (24″)■■ XL8340 (48″, routs 12 ″ OC)■■ XL8341 (48″, routs 12 ″ OC)■■ 833033 (1200mm, routs 300mm OC)■■ Other
■■ XL7342 (48″, routs 12″ OC)
■■ XL7318 (12″)■■ XL7368 (20″)■■ XL7328 (24″)■■ XL7378 (30″)■■ XL7348 (48″)■■ 312451 (300mm, center rout)■■ 312051 (600mm)■■ 313051 (1200mm, center rout)Fire Guard Items■■ XL8323 (24″)■■ 832052 (600mm)■■ Other
■■ XL7148 (48″, routs 12 ″ OC)■■ XL7128 (24″)
Materials
A. General: ASTM C635 (Intermediate-duty) (Heavy-duty) main beam classification, commercial-quality hot dipped galvanized steel. Exposedsurfaces chemically cleansed, galvanized steel or aluminum capping prefinished in baked polyester paint or annodized.
1/4"(6mm)
3/32"(2mm) 1-3/16"
(30mm)
15/16"(24mm)
1/4"(6mm)
1-3/8"(35mm)
15/16"(24mm)
1-11/16"(43mm)
9/16" (14mm)
1/4"
15/16"(24mm)
(6mm)
2C.
2D.
1/4" (6mm)1/4" (6mm)
1-11/16" (43mm)
1-1/2" (38mm)
15/16" (24mm)
15/16" (24mm)
(A) (B) Item # Length Flange Height■■ 7800 144″ 7/8″ 7/8″■■ 7807 120″ 2″ 1″■■ 7808 120″ 2″ 2″■■ HD7801 120″ 7/8″ 7/8″
(A) (B) (C)Item # Length Flange Height Reveal■■ 7875 120″ 3/4″ 15/16″ 1/2″
■■ 7877 120″ 15/16″ 15/16″ 1/4″■■ 7878 120″ 15/16″ 15/16″ 3/8″■■ 7897 120″ 15/16″ 15/16″ 1/2″
(A) (B) (C) Item # Length Flange Height Flange■■ 7835 120″ 7/8″ 1-3/4″ 9/16″
B
A
B
A
C
A
B
C
15/16" Exposed Tee System
PRELUDE® XL®RecycledContent: 30%
C o l o r S e l e c t i o n
■■ WH - White ■■ CR - Cream■■ HA - Haze ■■ VA - Vanilla†
■■ CM - Camel■■ YS - Oyster†
■■ PL - Platinum ■■ AD - Adobe†
■■ AR - Brass ■■ AM - Mirror ■■ BL - Tech Black ■■ SG - Silver Grey■■ MY - Gun Metal Grey
■■ ST - Slate■■ WK - Wolf†
■■ WA - White Aluminum
■■ NA - Natural Aluminum
■■ SA - Silver Satin■■ HDC - Hot Dipped
Clear Coat ■■ PW - Pewter†
■■ BZ - Bronze†
■■ SL - Silver†
† Only available on 7301, XL7342, XL7328, and 7800NOTE: Color chips included with samples of Armstrong grid.See your Armstrong representative for sample material.NOTE: Items 7305, 7302, XL7340, XL7380, XL7357,XL7358, XL7128, XL7148, XL7348, XL7330, XL7318,XL7368, XL7378, XL7390, XL8320, XL8341, XL7341 are available in white only. NOTE: 8300, XL8340 and XL8323 are available in whiteand black only.
3344 Prelude XL_610 7/9/10 3:26 PM Page 1
MaterialHot dipped galvanized steel
Surface FinishBaked polyester paint or anodized
Face Dimension15/16″
ProfileExposed tee
Cross Tee/Main Beam InterfaceOverride
End DetailMain Beam: Staked-on clipXL Cross Tee: Staked-on clip
Duty ClassificationIntermediate or Heavy-duty
Main Beam Load Test DataHANGER SPACING
MAIN WEB ASTM Lbs./LF. (Simple Span)**BEAMS LENGTH HEIGHT CLASS 4′ 5′7300 144″ 1-11/16″ Intermediate-duty 12.8 6.357301 144″ 1-11/16″ Heavy-duty 16.5 8.73
734032 144″ 1-11/16″ Intermediate-duty 12.8 6.358300/834033 144″ 1-11/16″ Intermediate-duty 12.8 6.35
8301 144″ 1-11/16″ Heavy-duty 16.5 8.737302 120″ 1-11/16″ Intermediate-duty 12.8 6.357305 140″ 1-11/16″ Intermediate-duty 12.8 6.35
Cross Tee Load Test DataHANGER SPACING
CROSS WEB Lbs./LF. (Simple Span)**TEES LENGTH HEIGHT 4′
XL7318/312451 12″ 1-3/8″ 40.45XL7368 20″ 1-3/8″ 40.45XL7128 24″ 1-3/16″ 33.0
XL7328/312051 24″ 1-3/8″ 40.45XL8323/832052 24″ 1-3/8″ 40.45
XL8320 24″ 1-11/16″ 61.33XL7378 30″ 1-3/8″ 16.54XL7330 36″ 1-11/16″ 23.11XL7148 48″ 1-3/16″ 6.0
XL8340/833033/ 48″ 1-11/16″ 12.25XL7340
XL7341/XL8341 48″ 1-1/2″ 16.59XL7342 48″ 1-1/2″ 9.00
XL7348/313051 48″ 1-3/8″ 8.31XL7357 60″ 1-11/16″ 7.61XL7358 60″ 1-11/16″ 7.61XL7380 96″ 1-11/16″ 12.12XL7390 72″ 1-11/16″ 12.23
Seismic PerformanceMINIMUM LBS. TO PULL OUT
MAIN BEAMS COMPRESSION/TENSION7300, 7302, 7305, 335.0734032, 8300
7301, 8301 330.0
MINIMUM LBS. TO PULL OUTCROSS TEES COMPRESSION/TENSION
All XL cross tees exceed 300 lbs. in both compression and tension.
ICC ReportsFor areas under ICC jurisdiction, see ICC evaluation report number 1308 for allowablevalues and/or conditions of use concerning the suspension system components listed onthis page. The report is subject to reexamination, revisions and possible cancellation.**To derive maximum lbs/SF, divide the on-center spacing of the component into the lbs/LF given in the
load test data table.
P h y s i c a l D a t a M a x i m u m F i x t u r e W e i g h t
LIGHT FIXTUREB. Cross Tee to Cross Tee
LIGHT FIXTUREA. Main Beam to
Main Beam
Main Beam ▲
Hanger Wire (•)
Main beams ▲
Hanger Wire (•)
1. Fixture* 24″ x 48″ 24″ x 24″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item XL8340/XL7340 69.27 lbs. 80.55 lbs.4. Item XL7342 40.89 lbs. 52.26 lbs.5. Item XL8341/XL7341 81.67 lbs. 100.0 lbs.
1. Fixture* 24″ x 48″ 12″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item XL8340/XL7340 49.27 lbs. 42.17 lbs.5. Item XL8341/XL7341 72.32 lbs. 63.32 lbs.
*Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is based on single fixtureonly. For end-to-end fixtures or other configurations not shown, consult your Armstrong representative.
NOTE: The above data is based on 48″ hanger wire spacing, board weight of 1 lb./SF, maximum deflection of teesnot to exceed 1/360 of the span, and suspension system installed in accordance with ASTM C636.
1. Fixture* 24″ x 48″ 24″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item 7300/8300 69.27 lbs. 49.27 lbs.
7302Item 7301/8301 100.0 lbs. 72.32 lbs.
1. Fixture* 12″ x 48″ 12″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item 7300/8300 54.26 lbs. 47.17 lbs.
7302Item 7301/8301 100.0 lbs. 63.32 lbs.
1. Fixture* 24″ x 48″ 20″ x 60″2. Planning Module 60″ x 60″ 60″ x 60″3. Hanger Spacing 48″ 48″4. Item 7300/8300 56.47 lbs. 43.21 lbs.
7305Item 7301/8301 56.47 lbs. 65.46 lbs.
Main Beams tested as follows: 7300 tested at 13.0 lbs./LF to 1/360 of 4′ span; 7301 tested at 16.5 lbs./LF to1/360 of 4′ span.
•••
• •••
••
•••
• •
••
• •
••
•••
• •••
•
• •
••
• •
••
•••
•
TechLineSM / 1 877 ARMSTRONG1 877 276 7876
armstrong.com/ceilingsCS-3344-710
All trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2010 AWI Licensing Company • Printed in the United States of America
15/16" Exposed Tee System
PRELUDE® XL®
3344 Prelude XL_610 7/9/10 3:26 PM Page 2
WOODWORKS® Linear Veneered Planks and Panels
Solid Wood Panels
■ Three different ways to achieve a linear look
■ Choose traditional planks, or fast, easy-to-install panels
■ Unique, new tapered visual available on veneered panels
■ FSC Certified: products represent responsible production and consumption practices from the forest to the consumer
■ Shorter lead times and lower cost than custom millwork
■ Custom veneers and stain matching available
Ceiling&Wall SyStemS
B e t w e e n u s , i d e a s b e c o m e r e a l i t y ™
2
WOODWORKS® Linear – Planks
WoodWorks Linear 8' x 3-3/4" in Custom Constants Light Cherry; Fox Lake District Library, Fox Lake, IL
WoodWorks Linear 3-3/4" Ceiling System in Natural Variations
Maple; Custom Installation at NaviNet, Inc., Boston, MA
Natural Variations™, Constants™, & Bamboo
V e n e e r S e l e c t i o n Due to printing limitations, shade may vary from actual product.
Natural Variations (Real Wood Veneers)
Beech (NBE)
Light Cherry (NLC)
Maple (NMP)
Dark Cherry (NDC)
** A premium veneer option managed through Architectural Specialties due to the potential for significant color variation panel to panel. Mininum order quantity and extended lead time may apply.
Bamboo (Rapidly Renewable)
Patina (BAP)
Native** (BAN)
Constants (Real Wood Veneers)
Maple (CMA)
Cherry (CCY)
Walnut (CWA)
You can also create beautiful curved looks with a faceted suspension system. Due to its non-standard suspension system, these S-Service items are ordered through Architectural Specialties at 1 877 ARMSTRONG, select options 1-1-4.
A d d i t i o n a l A t t r i b u t e s o f W o o d W o r k s L i n e a r P l a n k s■ Standard wood plank in 2 widths; nominal 4-1/2" and 6"
modules, with traditional 3/4” reveals
■ Standard factory-applied acoustical fleece
■ Install in the ceiling, on the wall, or create 90º angled or curved ceiling-to-wall transitions (one-foot minimum radius)
■ Create upturns for continuous visuals and clouds with veneer-wrapped WoodWorks Trim
■ Suspension system and planks from one manufacturer; improved for 30-50% faster installation
■ California Air Resources Board (CARB) compliant
■ 100% Biobased content certified by USDA BioPreferred® Products program (preferred for government projects)
■ Class A Fire Resistance
■ Custom veneers and stain matching available; for details, contact Architectural Specialties at 1 877 ARMSTRONG, select options 1-1-4
Cover Photo: WoodWorks Linear Ceiling System in Natural Variations Light Cherry; Fine Fissured™ Square Lay-in on Prelude® XL® suspension system; Side Street Inn, Honolulu, HI
3
L i n e a r P l a n k s V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n D o t s r e p r e s e n t h i g h e s t l e v e l o f p e r f o r m a n c e
WoodWorks Linear 8' x 3-3/4" in Natural Variations Light Cherry; Ceiling-to-Wall Faceted Transition
x
x x
Linear Carrier with
Integrated Clips Wood Plank
(Seismic Installation - Planks Screwed)
12 Ga. Hanger Wire
RC2BL Radius Clip
6459 Rigid Attachment Clip
Wall
Stud Kicker
Acoustical Fleece
FurringStrip
Linear Carrier with Integrated Clips
Wood Plank(Seismic Installation - Planks Screwed)
7805BL Angle Molding
1/4" Gap
Wall
Furring Strip
Acoustical Fleece
12 Ga. Hanger Wire
6459BL Rigid Attachment Clip
X
XX
X
WoodWorks Linear 8' x 3-3/4" in Natural Variations Light Cherry; Ceiling-to-Wall 90° Angle Transition
90º Ceiling-to-Wall System Assembly
C e i l i n g - t o - W a l l Tr a n s i t i o n s
Edge Profile
Item Number ◆
Dimensions
Acoustics NRC
Fire Rating
WooDWoRkS Linear – Nominal 4-1/2" Module
6440W1_ _ _ 8' x 3-3/4" x 3/4" with 3/4" reveal
0.50 0.65** •
Class A
6640W1_ _ _ (FSC®-certified)
8' x 3-3/4" x 3/4" with 3/4" reveal
0.50 0.65** •
Class A
WooDWoRkS Linear – Nominal 6" Module
6460W1 _ _ _ 8' x 5-1/4" x 3/4" with 3/4" reveal
0.40 0.50**
Class A
6660W1 _ _ _ (FSC-certified)
8' x 5-1/4" x 3/4" with 3/4" reveal
0.40 0.50**
Class A
◆ When specifying or ordering, please include the appropriate three-letter color suffix (e.g., 6460W1 N M P)
** Adding acoustical infill (item 8200100, 5479, or 5823) for 4-1/2" module increases the NRC to 0.65. Adding acoustical fiberglass infill for 6" module increases the NRC to 0.50.
Suspension SystemItem Number Description Dimensions Pieces/Carton
5370 12' HD Linear Carriers (concealed) with integral clips (factory-applied) for nominal 4-1/2" modules
12' x 15/16" x 1-11/16" 10 (Approx. 240 SF/ctn installed with planks)
5371 12' HD Linear Carriers (concealed) with integral clips (factory-applied) for nominal 6" modules
12' x 15/16" x 1-11/16" 10 (Approx. 240 SF/ctn installed with planks)
Note: For radiused applications, use standard panels and HD Linear Carriers faceted 12" on center with RC2BL clips.
Faceted Ceiling-to-Wall System Assembly
WOODWORKS® Linear – PlanksNatural Variations™, Constants™, & Bamboo
ColorsNV Beech (NBE)NV Maple (NMP)NV Light Cherry (NLC)
NV Dark Cherry (NDC) Constants Maple (CMA)Constants Cherry (CCY)
Constants Walnut (CWA) Bamboo Patina (BAP) Bamboo Native (BAN)
4
L i n e a r P l a n k s P h y s i c a l D a t a
L i n e a r P l a n k s A c c e s s o r y D e t a i l s
MaterialFire retardant particle board with face-cut veneers.FSC®-certified fire retardant particle board with face-cut veneers (SW-COC-3601). For more information about FSC-certified products or to view our FSC certification letter, visit armstrong.com/woodworksfscFactory-applied black fleece on each plank to cover the reveal.
Surface FinishClear or tinted semigloss coating
Fire Performance ASTM E84 surface burning characteristics, HPVA Certified with audit program per ASTM E84. Flame Spread Index 25 or less. Smoke Developed Index 50 or less.
CAN/ULC S102 surface burning characteristics. Flame Spread Rating 25 or less. Smoke Developed Classification 50 or less.
Linear wood, as with other architectural features located at the ceiling, may obstruct or skew the
planned fire sprinkler water distribution pattern, or possibly delay or accelerate the activation of the sprinkler or fire detection systems by channeling heat from a fire either toward or away from the device. Designers and installers are advised to consult a fire protection engineer, NFPA 13, and local codes for guidance where automatic fire detection and suppression systems are present.
ASTM E1264 ClassificationComposite – Fire Class A
Seismic RestraintLinear wood has been engineered, tested, and approved in all seismic areas.
Application ConsiderationsVariation among panels may occur due to the natural characteristics of the wood and grain.
It is very important that WoodWorks planks are climatized prior to installation. Relative humidity between 25% and 55% and temperatures between 50˚F and 86˚F must be maintained.
Installation ConsiderationsInstallation can use staggered, random joints for a monolithic appearance or consistent lengths for a modular style. For expansion, a 3/4" gap is recommended at every 24 foot run of plank. See installation instructions LA-297443 at armstrong.com/installation.
Specification ConsiderationAttention: For FSC-certified wood products to maintain their CoC certification, products must be sold to a CoC-certified distributor or directly to the installing contractor. Failure to do so breaks the CoC.
WarrantyOne (1) year limited warranty. Details: armstrong.com/warranty
Weight/Square Feet6440, 6640 – 2.88 lbs/SF 6460, 6660 – 2.89 lbs/SF(Bulk packaged)
A c c e s s o r i e s
Linear Fleece
Black Iron(min. 5'-0" long)
to span fromCarrier Channel to
Carrier Channel– by installer
#12 gauge HangerWire 4'-0" O.C.or as requiredby code
Uptight Clip – UTC
Access Panel Assemblyfield cut as required
Linear Carrier field cut andfastened to Support
Access Panel as required
Linear Carriersspaced 2'-0" O.C. (approx.)max. 4" from Access Panelfor stability
Ceiling Plane
1-1/2" x 1-1/2" Angle Molding (7805)
Wall
Linear Plank
Linear Plank
Linear Splice
Angle Molding (Item 7805BL) Detail Linear Splice (Item FXSPLICE) Detail Access Panel Assembly
Item Number Description Dimensions Pieces/Carton
5843 Linear Wood Panel Splice — 100
5659W1 _ _ _ ◆ 4" WoodWorks Trim (with aluminum substrate) 4" x 10' 6
5660W1 _ _ _ ◆ 6" WoodWorks Trim (with aluminum substrate) 6" x 10' 6
5948 Linear and Channeled Trim Connector Clip N/A 30
RC2BL Radius Clip for faceted suspension system applications (Black) — 205 pcs/bucket
7805BL** 10' Angle Molding (Tech Black) 10' x 1-1/2" x 1-1/2" 30
7823BL** 10' Shadow Molding (Tech Black) 10' x 2" x 1-1/4" x 3/4" 10
FXSPLICE Splice Plate with Setscrews for Trim N/A 10
6408_ _ _ ◆ 3/4" Edge Banding (factory-applied available upon request) 3/4" x 25' 25 foot roll
6459BL Rigid Attachment Clip (Black) 5-1/2" x 1-3/4" 25
92715A620 Self-tapping Screws (Black) #2 x 3/4" Length 25
7891 12 Gauge Hanger Wire 12' Length 140
8200100 FIberglass Infill Bag (Black - Gloss) 2' x 2' x 1' 12
5479 BioAcoustic™ Infill Panel (Beige - Matte) 2' x 2' x 5/8" 12
5823 BioAcoustic Infill Panel (Black - Matte) 2' x 2' x 5/8" 12◆ When specifying or ordering, include the appropriate three-letter color suffix that coordinates with your WoodWorks ceiling (e.g., 5659W1 B A P)
** This color is a special order item with these moldings.
Natural Variations™, Constants™, & BambooWOODWORKS® Linear – Planks LEED® Credits
Acoustics Low Emitting or CHPS
✔
LEED for Schools
RecycledContent:
Energy Waste Recycled Local Renewable Certified Low Mgmt Content Materials Materials Wood* Emitting*
✔ ✔ ✔ ✔ ✔ Location Dependent *Options Available
92% armstrong.com/greengenie
ColorsNV Beech (NBE)NV Maple (NMP)NV Light Cherry (NLC)
NV Dark Cherry (NDC) Constants Maple (CMA)Constants Cherry (CCY)
Constants Walnut (CWA) Bamboo Patina (BAP) Bamboo Native (BAN)
5
■ Unique tapered planks or traditional wood planks in nominal 4" or 6" width
■ Create continuous looks and clouds with veneer-wrapped and painted aluminum trim
■ Hook-on panels (for standard 15/16" suspension) provide safe and secure downward accessibility
■ Complete standard system from one manufacturer (grid/panels/trim)
■ Factory edge banded for superior quality
■ California Air Resources Board (CARB) compliant
■ 100% Biobased content certified by USDA BioPreferred® Product program
■ BioAcoustic™ infill available for increased acoustical performance
■ Acoustical fleece available as an option
■ Class A Fire Resistance
In addition to these standard options, there may be other sizes and veneers available. Contact the Armstrong Architectural Specialties project management team for details at 1 877 ARMSTRONG and select options 1-1-4.
V e n e e r S e l e c t i o n Due to printing limitations, shade may vary from actual product.
* A premium veneer option managed through Architectural Specialties due to the potential for significant color variation panel to panel. Mininum order quantity and extended lead time may apply.
Natural Variations (Real Wood Veneers)
Beech (NBE)
Light Cherry (NLC)
Maple (NMP)
Dark Cherry (NDC)
Bamboo (Rapidly Renewable)
Patina (BAP)
Native* (BAN)
A d d i t i o n a l A t t r i b u t e s o f W o o d W o r k s L i n e a r V e n e e r e d P a n e l s
Constants (Real Wood Veneers)
Maple (CMA)
Cherry (CCY)
Walnut (CWA)
WoodWorks Linear Veneer panels in tapered visual and Natural Variations Light Cherry finish.
WOODWORKS® Linear – PanelsNatural Variations™, Constants™, & Bamboo
Panelized Linear Veneer Tapered 2x8
Tapered Plank Panel
6
L i n e a r V e n e e r e d P a n e l s P h y s i c a l D a t a
Item Number Description Dimensions Pieces/Carton
5986 T-Bar Hook† Nominal 4" x 2" x 3" 50
91070A244 Wood Screws 5/8" 100
6091 Safety Cable 24" x 3/32" 50
SH12 Support Hanger 12' x 2" 12
† For 2' x 8' panel, install 8 hooks. Note: Three screws per hook. Note: Refer to installation instructions at armstrong.com/installation for a better understanding of suspension requirements.
Constants Maple (CMA)Constants Cherry (CCY)Constants Walnut (CWA)
NV Dark Cherry (NDC) Bamboo Patina (BAP) Bamboo Native (BAN)
NV Beech (NBE)NV Maple (NMP)NV Light Cherry (NLC)
Colors
LEED® Credits LEED for Schools
RecycledContent: 92% armstrong.com/greengenie
Acoustics Low Emitting or CHPS
✔ ✔
Energy Waste Recycled Local Renewable Certified Low Mgmt Content Materials Materials Wood* Emitting*
✔ ✔ ✔ ✔ ✔ Location Dependent * Options Available
SECTION C-CSCALE 1 / 2
SECTION D-DSCALE 1 / 2
C C
D D
WW Concealed Trim
XL7301BL12' HD Main Beam
WW Concealed T-Bar Hook
WW Concealed T-Bar Hook
Suspension System
15/16" Standard: Prelude® BL (Tech Black)
Installation Detail
A c c e s s o r i e s
Item Number Description Dimensions Nominal
Color Pieces/Carton
6603W1_ _ _ WoodWorks Concealed Trim◆◆ 6" x 10' Standard Veneers (see above) and Black (BL)
6
FXTBC T-Bar Connector Clip N/A N/A 10
FX4SPLICE Splice Plate with Setscrews N/A N/A 10
5823 BioAcoustic™ Infill Panel 2' x 2' x 5/8" Black 12
6408_ _ _ ◆ Edge Banding 25' x 3/4" Standard Veneers (see above) 1
◆ When specifying or ordering, include the two- or three-letter color suffix that coordinates with your WoodWorks ceiling (6408 N M P) ◆◆Trim cartons include FXTBC Clips and FX4SPLICE Plates.
EdgeProfile
ItemNumber ◆ Description
DimensionsNominal W x L x H NRC**
FSC®-certified WooDWoRkS Linear Veneered Panels
3/4" Reveal
1/4” Reveal
6690W1 _ _ _ Nominal 4" wide planks 2' x 8' x 3/4" 0.45
6691W1 _ _ _ Nominal 6" wide planks 2' x 8' x 3/4" 0.20
6692W1 _ _ _ Tapered planks 2' x 8' x 3/4" 0.20
◆ When specifying or ordering, include the appropriate three-letter color suffixes.
For veneers, sizes, and perforation patterns available as special order, call 1 877 ARMSTRONG and select options 1-1-4. To view more perforation information and build swatches in real time, visit armstrong.com/swatchit.
** NRC achieved with BioAcoustical™ infill (item 6657).
V i s u a l S e l e c t i o n A c o u s t i c a l P e r f o r m a n c e Dots represent highest level of acoustical performance
MaterialFSC-certified fire retardant particle board with face-cut veneers (SW-COC-003601). For more information about FSC-certified products or to view our FSC certification letter, visit armstrong.com/woodworksfsc6603 - Face-cut veneer or black paint on aluminum laminate substrate
Surface FinishClear or tinted semigloss coating
Fire Performance ASTM E84 surface burning characteristics, HPVA Certified with audit program per ASTM E84. Flame Spread Index 25 or less. Smoke Developed Index 50 or less.CAN/ULC S102 surface burning characteristics. Flame Spread Rating 25 or less. Smoke Developed Classification 50 or less.
ASTM E1264 ClassificationComposite – Fire Class A
Design ConsiderationsCloud installations with total panel width less than 6' wide are not recommended.Cloud installations with total panel length less than 16' wide cannot be done.
Application ConsiderationsVariation among panels may occur due to the natural characteristics of the wood and grain.Use of large wood panels may result in deflection up to 1/8" and alignment inconsistency due to size and ambient conditions.It is very important that WoodWorks panels are climatized prior to installation. Relative humidity between 25% and 55%, and temperatures between 50˚F and 86˚F must be maintained throughout the life of the product.
Specification ConsiderationAttention: For FSC-certified wood products to maintain their CoC certification, products must be sold to a CoC-certified distributor or directly to the installing contractor. Failure to do so breaks the CoC.
Seismic InstallationThese systems have been engineered, tested, and meet the requirements for applications in Seismic Design Categories D, E, and F.
WarrantyOne (1) year limited warranty. Details: armstrong.com/warranty
Weight/Square Feet6690, 6691, 6692 – 2.75 lbs/SF; bulk packed per order. Suspension, hardware, and accessories ordered separately.
WOODWORKS® Linear – PanelsNatural Variations™, Constants™, & Bamboo
PanelDimension/Type:2' x 8' Nominal4" wide planks
Finish:Natural Variations
Light Cherry
6690W1 NLC
EXAMPLE:
7a
H o w t o I n s t a l l Tr i m
Step 2: order T-Bar Hooks and Screws Based on Panel Size
Pre-drilled holesfor T-bar Hooks
2' x 4' Panel 2' x 6' Panel 2' x 8' Panel
T-bar Hook
Step 3: Install Hooks on Panels
A. B. C.
Step 1: Select Panel
Step 4: Install Panels
Pre-drilled holes for T-Bar Hooks
2' x 8' Panel T-Bar Hook
Panel Size
Number of Hooks Needed
Number of Screws Needed*
2' x 8' 8 24
*3 screws per hook
120" nominal
FinishedStandard
Trim Length
96-5/8"95-13/16"95-1/16"
72-5/8"71-13/16"71-1/16"
72-3/8"71-15/16"71-9/16"
4' LengthMitered onBoth Ends
47-1/16"
48-5/8"
47-13/16"T-Bar Hook Flange
Panel FlangeOutside Edges of Miter
6' LengthMitered on
One End
6' LengthMitered onBoth Ends
8' LengthMitered onBoth Ends
120" nominal
FinishedStandard
Trim Length
96-5/8"95-13/16"95-1/16"
72-5/8"71-13/16"71-1/16"
72-3/8"71-15/16"71-9/16"
4' LengthMitered onBoth Ends
47-1/16"
48-5/8"
47-13/16"T-Bar Hook Flange
Panel FlangeOutside Edges of Miter
6' LengthMitered on
One End
6' LengthMitered onBoth Ends
8' LengthMitered onBoth Ends
Black Powdercoat Finish
6.0"
FXTBC Location
Flange that alignsT-Bar Hook
Flangethat alignsPanel Edge
6"
H o w t o I n s t a l l W o o d W o r k s L i n e a r V e n e e r e d P a n e l s
Step 1: Cut and Miter Trim
FXTBC T-BarConnector Clip
XL7301BL12' HD Main Beam
Step 2: Attach Clips to Ends of Main Beams and Cross Tees
FX4SPLICESplice Plate
Step 4: Install Splice PlatesStep 3: Attach Trim to Clips
WW ConcealedTrim
FXTBC T-BarConnector Clip
Step 5: Install Panels
WW ConcealedTrim
FXTBC T-BarConnector Clip
XL7301BL12' HD Main Beam
WW ConcealedT-Bar Hook
WOODWORKS® Linear – PanelsNatural Variations™, Constants™, & Bamboo
WOODWORKS® Linear – Solid Wood Panels
In addition to these standard options, there are more finish and size choices available as custom options. Contact the Armstrong Architectural Specialties project management team for details at 1 877 ARMSTRONG and select prompts 1-1-4.
F i n i s h S e l e c t i o n Due to printing limitations, shade may vary from actual product.
Grille Maple (GMP)
Grille Dark Cherry
(GDC)
Grille Light Cherry
(GLC)
Grille Walnut (GWN)
A d d i t i o n a l A t t r i b u t e s o f W o o d W o r k s L i n e a r S o l i d W o o d P a n e l s■ Two plank widths – nominal 3" and
nominal 5" – in four rich finishes
■ Fast, easy installation – screw into suspension system or install with backer clip
■ Create continuous looks and clouds with solid wood trim
■ Complete standard system from one manufacturer
■ BioAcoustic™ infill available for increased acoustical performance
■ Acoustical fleece available as an option
Panelized Linear Solid 5" Nominal 1x8
WoodWorks Linear Solid Wood panels in Grille Dark Cherry.
Panelized Linear Solid 3" Nominal 1x8
7
T e g u l a r - V e c t o r V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n
WOODWORKS® Linear – Solid Wood Panels
L i n e a r S o l i d W o o d P a n e l s P h y s i c a l D a t a
Edge Profile
Item Number ◆
Description
Dimensions Nominal W x L x H
Acoustics NRC*
WooDWoRkS Linear Solid Wood Panels
6693W1 _ _ _ Nominal 3" wide planks 1' x 8' x 3/4" 0.60
6694W1 _ _ _ Nominal 5" wide planks 1' x 8' x 3/4" 0.50
* NRC achieved with acoustical infill (Item 6657).
NOTE: For additional color and size options, or acoustical felt available as a custom option, call Architectural Specialties at 1 877 ARMSTRONG and select options 1-1-4.
** When specifying or ordering, include the three-letter color suffix that coordinates with your WoodWorks ceiling: (e.g., 5671 G M P) * When specifying or ordering, include the appropriate three-letter color suffix.
V i s u a l S e l e c t i o n P e r f o r m a n c e S e l e c t i o n Dots represent highest level of performance.
TechLineSM / 1 877 ARMSTRONG armstrong.com/woodworksBPCS-4567-912
LEED® is a registered trademark of the U.S. Green Building Council All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2012 AWI Licensing Company • Printed in the United States of America
LEED® Credits Acoustics Low Emitting or CHPS
✔
LEED for Schools Energy Waste Recycled Local Renewable Daylight Mgmt Content Materials Materials & Views
✔ Location Dependent
armstrong.com/greengenie
A c c e s s o r i e s
MaterialPlanks and Backers – solid Pacific Albus
Surface FinishClear or tinted semigloss coating
Fire Performance Solid Hardwood Blades and Backers – ASTM E84 surface burning characteristics. Flame Spread Index 200 or less. Smoke Developed Index 450 or less. For improved Flame Spread performance, intumescent treatment is available.Fire performance will vary between wood species.Composite Linear Solid Wood Panels product testing has not been completed, since results will vary on a project-by-project basis. Contact TechLine at 1 877 ARMSTRONG for details.Woodworks Linear Solid Wood Panels, as with other architectural features located at the ceiling, may
obstruct or skew the planned fire sprinkler water distribution pattern, or possibly delay or accelerate the activation of the sprinkler or fire detection systems by channeling heat from a fire either toward or away from the device. Designers and installers are advised to consult a fire protection engineer, NFPA 13, and local codes for guidance where automatic fire detection and suppression systems are present.
Seismic RestraintWoodworks Linear Solid Wood Panels have been engineered, tested, and approved in all seismic areas.
Application ConsiderationsVariation among panels may occur due to the natural characteristics of the wood and grain.
Design Considerations It is very important that WoodWorks panels are climatized prior to installation. Relative humidity between 25% and 55% and temperatures between 50˚F and 86˚F must be maintained.
Installation ConsiderationSystem is designed to have a 1" gap between panels.Backer clip can only be used for installations of the panel with 3" nominal planks (Item 6693)
WarrantyOne (1) year limited warranty. Details: armstrong.com/warranty
Weight; Square Feet/Carton6693 – 1.25 lbs/SF 6694 – 1.25 lbs/SF (bulk packed)
Suspension Systems
15/16" Prelude® XL® (Black recommended)
Item Number Description Dimensions Nominal W x L x H
Color Pieces/Carton
7146 _ _ _ ◆
Solid Wood Trim 4" x 120" x 3/4" See Finishes Above Bulk
5687† Backer Clip 3/8" x 11/16" x 7/8" N/A 250 pcs/pail
5671 _ _ _ ◆ Ledger 1" x 96" x 1/4" See Finishes Above Bulk
7891 12 Gauge Soft Hanger Wire 12' Length N/A 140
92715A620 Self-tapping Screws #2 x 3/4" Length Black 25
6657 BioAcoustic™ Infill Panel 11" x 4' x 5/8" Black (Matte) 10
◆ When specifying or ordering, include the three-letter color suffix that coordinates with your WoodWorks ceiling: (e.g., 5671 G M P)
† Backer clip should only be used when installing panels with 3" wide nominal planks.
Flat PatternSCALE 1 : 1
.375
.583
n .100
.210
.125
85°
115°125°
.188
.020
R.020
R.020
.707
R.010
.191
.897
.935
.087
.888
e1
Wood is a natural product and will exhibit natural variations in color, grain, and texture, and knot holes of up to 1/2" in diameter.
Mtlair 23438.tif
Cmp 062_B.tif
Cmp 064_B.tif
WWSamples 23446_C.tif
Mtlair 23439.tif
Cmp 062_C.tif
WWSamples 23446_A.tif
Cmp 062_A.tif
Cmp 064_A.tif
WWSamples 23446_B.tif
Mtlair 23438.tif
Cmp 062_B.tif
Cmp 064_B.tif
WWSamples 23446_C.tif
Mtlair 23439.tif
Cmp 062_C.tif
WWSamples 23446_A.tif
Cmp 062_A.tif
Cmp 064_A.tif
WWSamples 23446_B.tif
Mtlair 23438.tif
Cmp 062_B.tif
Cmp 064_B.tif
WWSamples 23446_C.tif
Mtlair 23439.tif
Cmp 062_C.tif
WWSamples 23446_A.tif
Cmp 062_A.tif
Cmp 064_A.tif
WWSamples 23446_B.tif
FinishesGrille Maple (GMP)Grille Light Cherry (GLC)
Grille Dark Cherry (GDC) Grille Walnut (GWN)
K e y S e l e c t i o n A t t r i b u t e s
• Seismic Rx® SuspensionSystem saves time and money;ICC-ES approach to installations(ESR-1308)
• PeakForm® patented profileincreases strength andstability for improvedperformance duringinstallation
• SuperLock™2 main beam clipis engineered for a strong,secure connection and fastaccurate alignment confirmedwith an audible click; easy toremove and relocate
• Hot dipped galvanized coatinginhibits red rusting better thanelectrogalvanized or paintedsystems
• Rotary-stitched duringmanufacture by a patentedmethod for additional torsionalstrength and extra stabilityduring installation
• XL2 staked-on stab end detailprovides tight, secure lockedconnection; easy to remove, reuse and relocate
• State-of-the-art expansion reliefon Fire Guard™ options;provides greater strength andprohibits distortion of grid faceduring installation
• 10-year limited warranty; 30-year with HumiGuard® Plus
Ty p i c a l A p p l i c a t i o n s
• Retail
• Education
• Offices
• Hospitality
• Fire Guard applications basedon building construction andlocal fire code requirements
P r o d u c t D e s c r i p t i o n
B. Components:1. Main Beams: Double-web
construction, web height 1-11/16″with peaked roof top bulb and15/16″ bottom flange withprefinished steel or aluminumcapping*; one fire expansion reliefper fire rated main beam.
* NOTE: Fire Guard items available insteel capping only.
2A. Cross Tee: Double-web construction,web height 1-11/16″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2B. Cross Tee: Double-web construction,web height 1-1/2″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2C. Cross Tee: Double-web construction,web height 1-3/8″, 15/16″ bottomflange with prefinished steel oraluminum capping and override ateach end. Staked-on end detailallows easy cross tee removal andremounting.
2D. Cross Tee: Double-web construction,web height 1-3/16″, 15/16″ bottomflange with prefinished steel cap andoverride at each end. Staked-on enddetail allows easy cross tee removaland remounting.
Wall Moldings:3A. Angle molding: hemmed with
prefinished exposed flanges
3B. Shadow molding: hemmed withprefinished exposed flanges
3C. Shadow Molding: (Compatible with Seismic Rx® and BERC 2)
3D. Channel molding: hemmed withprefinished exposed flanges
■■ 7300 (144″, routs 6″ OC, Intermediate-duty)■■ 7301 (144″, routs 6″ OC, Heavy-duty)■■ 7302 (120″, routs 6″ OC, Intermediate-duty)■■ 7305 (140″, routs 10″ OC, Intermediate-duty)■■ 734032 (3600mm, routs 150mm OC, Intermediate-duty)Fire Guard Items■■ 8300 (144″, routs 6″ OC, Intermediate-duty)■■ 8301 (144″, routs 6″ OC, Heavy-duty)■■ 834033 (3600mm, routs 150mm OC,
Intermediate-duty)■■ Other
■■ XL7340 (48″, routs 12″ OC)■■ XL7341 (48″, routs 12″ OC)■■ XL7330 (36″)■■ XL7380 (96″, routs 12″ OC)■■ XL7357 (60″, routs 6″ OC)■■ XL7358 (60″, routs 20″ OC)■■ XL7390 (72″, routs 12″ OC)Fire Guard Items■■ XL8320 (24″)■■ XL8340 (48″, routs 12 ″ OC)■■ XL8341 (48″, routs 12 ″ OC)■■ 833033 (1200mm, routs 300mm OC)■■ Other
■■ XL7342 (48″, routs 12″ OC)
■■ XL7318 (12″)■■ XL7368 (20″)■■ XL7328 (24″)■■ XL7378 (30″)■■ XL7348 (48″)■■ 312451 (300mm, center rout)■■ 312051 (600mm)■■ 313051 (1200mm, center rout)Fire Guard Items■■ XL8323 (24″)■■ 832052 (600mm)■■ Other
■■ XL7148 (48″, routs 12 ″ OC)■■ XL7128 (24″)
Materials
A. General: ASTM C635 (Intermediate-duty) (Heavy-duty) main beam classification, commercial-quality hot dipped galvanized steel. Exposedsurfaces chemically cleansed, galvanized steel or aluminum capping prefinished in baked polyester paint or annodized.
1/4"(6mm)
3/32"(2mm) 1-3/16"
(30mm)
15/16"(24mm)
1/4"(6mm)
1-3/8"(35mm)
15/16"(24mm)
1-11/16"(43mm)
9/16" (14mm)
1/4"
15/16"(24mm)
(6mm)
2C.
2D.
1/4" (6mm)1/4" (6mm)
1-11/16" (43mm)
1-1/2" (38mm)
15/16" (24mm)
15/16" (24mm)
(A) (B) Item # Length Flange Height■■ 7800 144″ 7/8″ 7/8″■■ 7807 120″ 2″ 1″■■ 7808 120″ 2″ 2″■■ HD7801 120″ 7/8″ 7/8″
(A) (B) (C)Item # Length Flange Height Reveal■■ 7875 120″ 3/4″ 15/16″ 1/2″
■■ 7877 120″ 15/16″ 15/16″ 1/4″■■ 7878 120″ 15/16″ 15/16″ 3/8″■■ 7897 120″ 15/16″ 15/16″ 1/2″
(A) (B) (C) Item # Length Flange Height Flange■■ 7835 120″ 7/8″ 1-3/4″ 9/16″
B
A
B
A
C
A
B
C
15/16" Exposed Tee System
PRELUDE® XL®RecycledContent: 30%
C o l o r S e l e c t i o n
■■ WH - White ■■ CR - Cream■■ HA - Haze ■■ VA - Vanilla†
■■ CM - Camel■■ YS - Oyster†
■■ PL - Platinum ■■ AD - Adobe†
■■ AR - Brass ■■ AM - Mirror ■■ BL - Tech Black ■■ SG - Silver Grey■■ MY - Gun Metal Grey
■■ ST - Slate■■ WK - Wolf†
■■ WA - White Aluminum
■■ NA - Natural Aluminum
■■ SA - Silver Satin■■ HDC - Hot Dipped
Clear Coat ■■ PW - Pewter†
■■ BZ - Bronze†
■■ SL - Silver†
† Only available on 7301, XL7342, XL7328, and 7800NOTE: Color chips included with samples of Armstrong grid.See your Armstrong representative for sample material.NOTE: Items 7305, 7302, XL7340, XL7380, XL7357,XL7358, XL7128, XL7148, XL7348, XL7330, XL7318,XL7368, XL7378, XL7390, XL8320, XL8341, XL7341 are available in white only. NOTE: 8300, XL8340 and XL8323 are available in whiteand black only.
3344 Prelude XL_610 7/9/10 3:26 PM Page 1
MaterialHot dipped galvanized steel
Surface FinishBaked polyester paint or anodized
Face Dimension15/16″
ProfileExposed tee
Cross Tee/Main Beam InterfaceOverride
End DetailMain Beam: Staked-on clipXL Cross Tee: Staked-on clip
Duty ClassificationIntermediate or Heavy-duty
Main Beam Load Test DataHANGER SPACING
MAIN WEB ASTM Lbs./LF. (Simple Span)**BEAMS LENGTH HEIGHT CLASS 4′ 5′7300 144″ 1-11/16″ Intermediate-duty 12.8 6.357301 144″ 1-11/16″ Heavy-duty 16.5 8.73
734032 144″ 1-11/16″ Intermediate-duty 12.8 6.358300/834033 144″ 1-11/16″ Intermediate-duty 12.8 6.35
8301 144″ 1-11/16″ Heavy-duty 16.5 8.737302 120″ 1-11/16″ Intermediate-duty 12.8 6.357305 140″ 1-11/16″ Intermediate-duty 12.8 6.35
Cross Tee Load Test DataHANGER SPACING
CROSS WEB Lbs./LF. (Simple Span)**TEES LENGTH HEIGHT 4′
XL7318/312451 12″ 1-3/8″ 40.45XL7368 20″ 1-3/8″ 40.45XL7128 24″ 1-3/16″ 33.0
XL7328/312051 24″ 1-3/8″ 40.45XL8323/832052 24″ 1-3/8″ 40.45
XL8320 24″ 1-11/16″ 61.33XL7378 30″ 1-3/8″ 16.54XL7330 36″ 1-11/16″ 23.11XL7148 48″ 1-3/16″ 6.0
XL8340/833033/ 48″ 1-11/16″ 12.25XL7340
XL7341/XL8341 48″ 1-1/2″ 16.59XL7342 48″ 1-1/2″ 9.00
XL7348/313051 48″ 1-3/8″ 8.31XL7357 60″ 1-11/16″ 7.61XL7358 60″ 1-11/16″ 7.61XL7380 96″ 1-11/16″ 12.12XL7390 72″ 1-11/16″ 12.23
Seismic PerformanceMINIMUM LBS. TO PULL OUT
MAIN BEAMS COMPRESSION/TENSION7300, 7302, 7305, 335.0734032, 8300
7301, 8301 330.0
MINIMUM LBS. TO PULL OUTCROSS TEES COMPRESSION/TENSION
All XL cross tees exceed 300 lbs. in both compression and tension.
ICC ReportsFor areas under ICC jurisdiction, see ICC evaluation report number 1308 for allowablevalues and/or conditions of use concerning the suspension system components listed onthis page. The report is subject to reexamination, revisions and possible cancellation.**To derive maximum lbs/SF, divide the on-center spacing of the component into the lbs/LF given in the
load test data table.
P h y s i c a l D a t a M a x i m u m F i x t u r e W e i g h t
LIGHT FIXTUREB. Cross Tee to Cross Tee
LIGHT FIXTUREA. Main Beam to
Main Beam
Main Beam ▲
Hanger Wire (•)
Main beams ▲
Hanger Wire (•)
1. Fixture* 24″ x 48″ 24″ x 24″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item XL8340/XL7340 69.27 lbs. 80.55 lbs.4. Item XL7342 40.89 lbs. 52.26 lbs.5. Item XL8341/XL7341 81.67 lbs. 100.0 lbs.
1. Fixture* 24″ x 48″ 12″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item XL8340/XL7340 49.27 lbs. 42.17 lbs.5. Item XL8341/XL7341 72.32 lbs. 63.32 lbs.
*Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is based on single fixtureonly. For end-to-end fixtures or other configurations not shown, consult your Armstrong representative.
NOTE: The above data is based on 48″ hanger wire spacing, board weight of 1 lb./SF, maximum deflection of teesnot to exceed 1/360 of the span, and suspension system installed in accordance with ASTM C636.
1. Fixture* 24″ x 48″ 24″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item 7300/8300 69.27 lbs. 49.27 lbs.
7302Item 7301/8301 100.0 lbs. 72.32 lbs.
1. Fixture* 12″ x 48″ 12″ x 48″2. Planning Module 48″ x 48″ 48″ x 48″3. Hanger Spacing 48″ 48″4. Item 7300/8300 54.26 lbs. 47.17 lbs.
7302Item 7301/8301 100.0 lbs. 63.32 lbs.
1. Fixture* 24″ x 48″ 20″ x 60″2. Planning Module 60″ x 60″ 60″ x 60″3. Hanger Spacing 48″ 48″4. Item 7300/8300 56.47 lbs. 43.21 lbs.
7305Item 7301/8301 56.47 lbs. 65.46 lbs.
Main Beams tested as follows: 7300 tested at 13.0 lbs./LF to 1/360 of 4′ span; 7301 tested at 16.5 lbs./LF to1/360 of 4′ span.
•••
• •••
••
•••
• •
••
• •
••
•••
• •••
•
• •
••
• •
••
•••
•
TechLineSM / 1 877 ARMSTRONG1 877 276 7876
armstrong.com/ceilingsCS-3344-710
All trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2010 AWI Licensing Company • Printed in the United States of America
15/16" Exposed Tee System
PRELUDE® XL®
3344 Prelude XL_610 7/9/10 3:26 PM Page 2