Upload
trinhnga
View
222
Download
3
Embed Size (px)
Citation preview
PROPOSED DWELLING FOR
O'CONNOR40
BANKSIA BROADWAY,BURLEIGH WATERS
JOB NUMBER - 3724
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
2 21
DESCRIPTIONREV. DATE
PRELIMINARY PLANS ISSUEDA 030210
GENERAL NOTESDO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERINGMATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKSCONFORM TO THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIANSTANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS,REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OFAUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
AS 1288 - 1994 GLASS IN BUILDINGS - SELECTION AND INSTALLATIONAS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDINGAS 1684 - 1999 NATIONAL TIMBER FRAMING CODEAS 2049 - 1992 ROOF TILESAS 2050 - 1995 INSTALLATION OF ROOF TILESAS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTIONAS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGSAS 3600 - 1994 CONCRETE STRUCTURESAS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITESAS 3700 - 1998 MASONRY IN BUILDINGSAS 3740 - 1994 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGSAS 3786 - 1993 SMOKE ALARMSAS 4055 - 1992 WIND LOADINGS FOR HOUSINGAS 4100 - 1996 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVILENGINEERING COMPUTIONS AND DRAWINGS.
SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCEWITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOXINDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOORii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASEiii) FULLY GLAZED DOORSiv) SHOWER SCREENSv) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVELvi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARYWITH MANUFACTURER, FLASHING ALL ROUND.
ALL GUTTERS TO BE STRAMIT GUEENSLANDER QUAD GUTTERING WITH MIN. 100x75RECTANGULAR OR 100 dia. DOWNPIPES, EACH DOWNPIPE TO SERVICE A MAX. 36 sq.mOF ROOF AREA, IN ACCORDANCE WITH AS 3500.3.2
STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BYTHE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVERTHEFLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OFPARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALLCORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT ISRECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITYOF BUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BEIMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OFTHE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL ANDWITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sqFOR INTERNAL WALLS BELOW BEARER.
THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5 BATTS AND REFLECTIVE FOILTO EXTERNAL WALLS OR AS PER ENERGY RATING.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND INACCORDANCE WITH BCA 3.9.2FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADECONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLEDEFLECTION) OF THE BCA..
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OFEXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
LEGENDCJ CONSTRUCTION JOINTDP DOWNPIPEFP FIRE PLACEFW FLOOR WASTEHWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBESD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BIULDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans), TOBE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.
WIND SPEED AS NOMINATED ON BRACING PLAN.
PROVIDE LIFT OFF HINGES TO W.C OR OPEN OUT DOOR OR MIN 1200mm CLEARANCEFROM DOOR TO PAN.
EXHAUST FANS FROM SANITARY COMPARTMENTS TO BE DUCTED TO THE OUTSIDEARE AIR OR TO A VENTED ROOF SPACE AND AS PER AS 1668.2
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGUALTIONS,STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACUAL OBLIGATIONS.
ALL CONSTRUCTION MATERIALS SUPPLIED MUST TAKE INTO ACCOUNT PROXIMITY TOCOASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCE WITH MANUFACTURERSSPECIFICATIONS
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THEAUTHOR.
RAIN WATER STORAGE TANKS IN ACCORDANCEWITH QUEENSLAND DEVELOPMENT CODE - PART4.2 & 4.3
MANDATORY RAINWATER TANK 3000L PER DUPLEX UNIT, 5000L PERSINGLE DETACHED DWELLING, FOR WC'S, WASHING MACHINE COLDWATER TAPS & EXTERNAL TAPS. LOCATION TBC ON SITE TOPROVIDE THE LESSER OF 100m2 OR HALF-ROOF CATCHMENT AREA,WITH 15 LITRE FIRST FLUSH DIVERSION AS PER BUILDER. AUTOSWITCHING DEVICE OR TRICKLE TOP-UP SYSTEM REQUIREDATTACHED TO TOWN WATER, WITH BACKFLOW PREVENTIONDEVICE. ALL TANKS TO BE MIN 450mm FROM SIDE OR REARBOUNDARY. TANKS OVER 2.4M HIGH TO BE MIN 1.5M FROM SIDE ORREAR BOUNDARY. RELAXATION REQUIRED FOR TANKS IN 6M FRONTSETBACK. OVERFLOW TO BE CONNECTED TO LEGAL POINT OFDISCHARGE.
SITE NOTESALL STORMWATER AND DRAINAGE TO BE IN COMPLIANCE WITHBCA PARTS 3.1.2 & 3.5.2 AS WELL AS AS/NZS 3500.
ENSURE 90mm DIAMETER AGRICULTURAL DRAINS AREPROVIDED TO THE BASE OF ALL CUTS AND RETAINING WALLSAND ARE CONNECTED TO THE STORMWATER SYSTEM VIA SILTPIT/S TO THE RBS REQUIREMENTS.
THE EXTERNAL FINISHED SURFACE SURROUNDING THEBUILDING MUST BE DRAINED TO MOVE SURFACE WATER AWAYFROM THE BUILDING AND GRADE TO PROVIDE A SLOPE NOTLESS THAN 50mm OVER THE FIRST 1000mm FROM THEBUILDING.
THE HEIGHT OF THE OVERFLOW RELIEF GULLY RELATIVE TODRAINAGE FITTINGS AND GROUND LEVEL MUST BE A MINIMUMOF 150mm BELOW THE LOWEST SANITARY FIXTURE
CONNECT DOWNPIPES TO LEGAL POINT OF DISCHARGE VIA100mm DIAMETER UPVC STORMWATER PIPE LAID WITH AMINIMUM FALL OF 1:80, DISCHARGE TO THE SATISFACTION OFTHE RELEVANT AUITHORITY.
2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE,SUBSURFACE PIPES TO BE 100mm DIAMETER, ANY UNDERSLABPIPING TO HAVE AN INSPECTION OPENING AT UPPER END, IT ISTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDERSLAB.
ALL POOL FENCING SHALL BE MIN. 1200mm HIGH ANDINACCORDANCE WITH AS 1926.1
PROPOSED DWELLING FORO'CONNOR
40BANKSIA BROADWAY,BURLEIGH WATERS
JOB NUMBER - 3724
AMENDED PRELIMINARY PLANS ISSUEDB 090210
WORKING DRAWINGS ISSUEDC 120210
AMENDED WORKING DRAWINGS ISSUEDD 160210
AMENDED WORKING DRAWINGS ISSUED - FRONT HOOD REDUCEDE 030310
AMENDED WORKING DRAWINGS ISSUEDF 260310
AMENDED WORKING DRAWINGS ISSUEDG 310310
AMENDED WORKING DRAWINGS ISSUEDH 310310
10.8
7
Site
Ben
chm
ark
Nail
in K
erb
RL 1
0.00
GUL
LY P
ITG
ULLY
PIT
TMH
TELS
TRA
PIT
TMH
TELS
TRA
PIT
WM
WAT
ER M
ETER
EPP
POW
ER P
OLE
45 10
40 10
28 10
05 10
95 9
990
9 9 2
9 90
1074
1033
1042
1070
1021
1018
Floo
r Lev
elRL
11.
58
1093
1095
1094
1094
109510
96
1094
1094
1063 10
8910
8910
89
1091
1102
1099 97
10
1094
1311
1111
0411
1071
1099
1097
10.9
2
11.3
911
.01
11.0
8
11.1
110
.97
11.1
011
.12
10.7
710
.77
10.6
9
11.0
010
.93
10.8
5
11.4
8
10.8
8
11.3
710
.87
10.9
311
.4010
.67
10.6
8
10.9
1
10.9
4
10.9
4
11.0
2
13.2
2
11.0
111
.05
11.1
0
11.0
9
11.2
1
10.9
2
10.8
911
.08
10.9
511
.08
11.3
1
11.1
7
11.1
3
18.2
0590
°43 '
00"
19.0
9527
0°43
'00 "
32.995 0°43'00"
33.005179°10'00"
10.7
5
11.0
0
1 0. 2
5
11 .00 11.0010.7
5
11.2
5
11.0
0
050
mm
mm
100
mm
150
0 - S
CALE
IN M
ETRE
S10
mm
20m
30
#40
BANK
SIA
BRO
ADW
AYBU
RLEI
GH
WAT
ERS
ALAN
SUL
LIVA
N &
ASSO
CIAT
ES P
/L T
AKE
NO
SERV
ICES
WAR
NING
ALAN
SUL
LIVA
N &
ASSO
CIAT
ES P
/L H
AS N
OT
FLO
OD
SEAR
CH W
ARNI
NGCHECKED
TK
SURVEYOR
CONT
OUR
& D
ETAI
LSU
RVEY
1:20
0 @
A3
COPY
RIGH
T AL
AN S
ULLI
VAN
& AS
SOCI
ATES
PTY
LTD
, 201
0c
PO B
ox 3
852,
Bur
leigh
Tow
n, Q
LD, 4
220
8/12
Ern
Har
ley D
rive,
Bur
leigh
Hea
ds, Q
LD, 4
220
Ph (0
7) 55
22 1
445,
Fax
(07)
5522
144
9Mo
b 04
12 6
71 6
30, E
mail a
dmin@
asur
vey.c
om.a
uAB
N 15
006
622 7
60
ALAN
SUL
LIVA
N&
Asso
ciate
s Pt
y. L
td.
Cons
ultin
g Su
rvey
ors
ASSU
MED
LEV
EL D
ATUM
NAIL
IN K
ERB
RL 1
0.0
TITL
E SE
ARCH
WAR
NING
Site
Lot:
Clie
ntST
UART
OSM
ANBU
ILDI
NG D
ESIG
N
DRAWINGNUMBER
1/1
-
REVISION
SHEET
SCALE
LEVELDATUM
JOBNUMBER
DATE
18/1
/201
0
DRAWN
DLJW
10.2
307
10.2
307.
01
Stre
et /
Road
:
Subu
rb:
Loca
l Aut
horit
y:
Paris
h:
UBD
Ref:
on R
P/SP
:
Coun
ty:
Area
:
3RP
1377
06
COUN
CIL O
F TH
E CI
TY O
F GO
LD C
OAST
GIL
STO
NW
ARD
-61
5sqm
Note
sTH
IS P
LAN
HAS
BEEN
PRE
PARE
D FR
OM
FIE
LD S
URVE
Y AN
DEX
ISIT
ING
REC
OR
DS
FOR
OU
R C
LIEN
TS T
O D
ESIG
N N
EWST
RUCT
URES
ON
THIS
SIT
E AN
D SH
OUL
D NO
T BE
USE
D FO
RAN
Y O
THER
PU
RPO
SE O
R B
Y AN
Y O
THER
PER
SON
S O
RC
OR
POR
ATIO
NS
WIT
HO
UT
WR
ITTE
N A
PPR
OVA
L FR
OM
ALA
NSU
LLIV
AN &
ASS
OCI
ATES
P/L
. NO
N-VI
SIBL
E SE
RVIC
ES H
AVE
NOT
BEEN
PLO
TTED
BUT
, ARE
AVA
ILAB
LE F
ROM
THE
LO
CAL
AUTH
OR
ITY
OR
AG
ENT
WH
ICH
HAV
E LI
MIT
IED
AN
D V
ARIE
DAC
CU
RAC
Y. IT
IS T
HE
PLAN
USE
RS
RES
PON
SIBI
LITY
TO
ACC
UR
ATEL
Y LO
CAT
E AN
D/O
R E
XPO
SE A
NY
NO
N-V
ISIB
LESE
RVI
CES
AN
D D
ETER
MIN
E W
HET
HER
TIT
LE E
NC
UM
BRAN
CES
WIL
L PR
EVEN
T O
R L
IMIT
DEV
ELO
PMEN
T AN
D T
O C
HEC
K O
N,
THE
LOC
AL A
UTH
OR
ITY'
S D
EFIN
ITIO
N O
F N
ATU
RAL
GR
OU
ND
LEVE
L, P
RIOR
TO
CONS
TRUC
TION
COM
MEN
CING
.[S
EE W
ARNI
NG N
OTES
ON
THE
FACE
OF
PLAN
FOR
MOR
E DE
TAIL
S]
ALAN
SUL
LIVAN
& A
SSOC
IATE
S P/
L HAS
NOT
CAR
RIED
OUT
A TI
TLE
SEAR
CH F
OR T
HIS
SURV
EY. C
HECK
DNR&
W F
OR E
ASEM
ENTS
AND
ENC
UMBR
ANCE
S.
RESP
ONSI
BILI
TY F
OR T
HE L
OCAT
ION
OF A
NY N
ON-V
ISIB
LE S
ERVI
CE
COM
PLET
ED A
FLO
OD S
EARC
H ON
THI
S PR
OPER
TY.
CHEC
K CO
UNCI
L FL
OO
D IN
FORM
ATIO
N.
Serv
ices
Sewe
rage
:St
orm
wate
r:W
ater
:El
ectri
city:
Tele
phon
e:G
as:
Yes (
Esta
blish
ed)
Yes (
To K
erb)
Yes
Yes (
Ove
rhea
d)Ye
s (Un
derg
roun
d)No
Road
:Bi
tum
enKe
rb:
Yes (
Mou
ntab
le)
Foot
path
:No
Floo
d Le
vel:
POTE
NTIA
L FL
OOD
INUN
DATI
ONCA
LL G
CCC
1300
366
659
FOR
REP
ORT
BRICK FENCE
10.5
0
10.0
0
B A
N K
S I A
B R
O A
D W
A Y
Lot 3
TOP
OF
KERB
# 40
SING
LE S
TORE
YBR
ICK
& TI
LERE
SIDE
NCE
P O
O LPA
VED
AREA
EASEMENT A
CARP
ORT
BRIC
K F
ENCE
PAVED AREA
COLOURBOND FENCECOLOURBOND FENCE
BLO
CK
F E
NCE
COLOURBOND FENCE
CONC
CONC
#42
SING
LE S
TORE
YBR
ICK
& TI
LERE
SIDE
NCE
#38
SING
LE S
TORE
YRE
NDER
ED R
ESID
ENCE
Floo
r Lev
elRL
11.
15
PAVE
D AR
EA
24-0
6alw
24-0
6alw
24-0
6alw
820 820
820
820
820
24-3
0stac
ker
720
820
1 2 3 4 5 6 7 8 9 10 11 12 13 14
D.PD.PD.PD.P
D.PD.P D.P
4846
3631
12220
6106
10.87
S i t e Benchmark
Na i l i n KerbRL 10 .00
GULLY P ITGULLY P IT
TMH
TELSTRA P I TTM
HTELSTRA P I T
WM
WATER M
ETER
EPPPO
WER PO
L E
4 5 1 0
4 0 1 0
2 8 1 0
0 5 1 0
95 9
99 0
9 9 2
9 90
1074
1033
1042
1070
1 021
1018
1 093
1095
1094
1094
109510
9610
94
1094
1063
1 089
1089
1089
1091
1102
1099 97
10
1 094
1311
1111
0 411
1071
1099
1097
10.92
11.3911.01
11.08
11.1110.97
11.1011.12
10.7710.77
10.69
11.0010.93
10.85
11.48
10.88
11.3710.87
10.93 11.40
10.6710.68
10.91
10.94
10.94
11.02
13.2211.0111.05
11.10
11.09
11.21
10.92
10.8911.08
10.9511.08
11.31
11.17
11.13
18.2
0590
°43 '
00"
19.0
9527
0°43
'00 "
3 2 . 9 9 5 0°43 '00"
3 3 . 0 0 5179°10 '00 "
10.7
5
11.0
0
1 0. 2
5
11 .00
11.0010
.75
11 .25
11.0
0
B R I C K F E N C E
10.5
0
10.00
B A N K S I A B R O A D W
A Y
Lot 3
TOP O
F K ERB
P O O
L
PAVED AREA
EASEMENT A
BR ICK F ENCE
P A V E D A R E A
C O L O U R B O N D F E N C E C O L O U R B O N D F E N C E
BLOCK FENCE
C O L O U R B O N D F E N C E
CONC
CONC
# 4 2S I N G L E S T O R E Y
B R I C K & T I L ER E S I D E N C E
# 3 8S I N G L E S T O R E Y
R E N D E R E D R E S I D E N C E
to wall
to patio
to wall
to w
all
to wall
050
mm
mm
100
mm
150
0 - S
CALE
IN M
ETRE
S10
mm
20m
30
#40
BANK
SIA
BRO
ADW
AYBU
RLEI
GH
WAT
ERS
ALAN
SUL
LIVA
N &
ASSO
CIAT
ES P
/L T
AKE
NO
SERV
ICES
WAR
NING
ALAN
SUL
LIVA
N &
ASSO
CIAT
ES P
/L H
AS N
OT
FLO
OD
SEAR
CH W
ARNI
NG
CHECKED
TK
SURVEYOR
CONT
OUR
& D
ETAI
LSU
RVEY
1:20
0 @
A3
COPY
RIGH
T AL
AN S
ULLI
VAN
& AS
SOCI
ATES
PTY
LTD
, 201
0c
PO B
ox 3
852,
Bur
leigh
Tow
n, Q
LD, 4
220
8/12
Ern
Har
ley D
rive,
Bur
leigh
Hea
ds, Q
LD, 4
220
Ph (0
7) 55
22 1
445,
Fax
(07)
5522
144
9Mo
b 04
12 6
71 6
30, E
mail a
dmin@
asur
vey.c
om.a
uAB
N 15
006
622 7
60
ALAN
SUL
LIVA
N&
Asso
ciate
s Pt
y. L
td.
Cons
ultin
g Su
rvey
ors
ASSU
MED
LEV
EL D
ATUM
NAIL
IN K
ERB
RL 1
0.0
TITL
E SE
ARCH
WAR
NING
Site
Lot:
Clie
ntST
UART
OSM
ANBU
ILDI
NG D
ESIG
N
DRAWINGNUMBER
1/1
-
REVISION
SHEET
SCALE
LEVELDATUM
JOBNUMBER
DATE
18/1
/201
0
DRAWN
DLJW
10.2
307
10.2
307.
01
Stre
et /
Road
:
Subu
rb:
Loca
l Aut
horit
y:
Paris
h:
UBD
Ref:
on R
P/SP
:
Coun
ty:
Area
:
3RP
1377
06
COUN
CIL O
F TH
E CI
TY O
F GO
LD C
OAST
GIL
STO
NW
ARD
-61
5sqm
Note
sTH
IS P
LAN
HAS
BEEN
PRE
PARE
D FR
OM
FIE
LD S
URVE
Y AN
DEX
ISIT
ING
REC
OR
DS
FOR
OU
R C
LIEN
TS T
O D
ESIG
N N
EWST
RUCT
URES
ON
THIS
SIT
E AN
D SH
OUL
D NO
T BE
USE
D FO
RAN
Y O
THER
PU
RPO
SE O
R B
Y AN
Y O
THER
PER
SON
S O
RC
OR
POR
ATIO
NS
WIT
HO
UT
WR
ITTE
N A
PPR
OVA
L FR
OM
ALA
NSU
LLIV
AN &
ASS
OCI
ATES
P/L
. NO
N-VI
SIBL
E SE
RVIC
ES H
AVE
NOT
BEEN
PLO
TTED
BUT
, ARE
AVA
ILAB
LE F
ROM
THE
LO
CAL
AUTH
OR
ITY
OR
AG
ENT
WH
ICH
HAV
E LI
MIT
IED
AN
D V
ARIE
DAC
CU
RAC
Y. IT
IS T
HE
PLAN
USE
RS
RES
PON
SIBI
LITY
TO
ACC
UR
ATEL
Y LO
CAT
E AN
D/O
R E
XPO
SE A
NY
NO
N-V
ISIB
LESE
RVI
CES
AN
D D
ETER
MIN
E W
HET
HER
TIT
LE E
NC
UM
BRAN
CES
WIL
L PR
EVEN
T O
R L
IMIT
DEV
ELO
PMEN
T AN
D T
O C
HEC
K O
N,
THE
LOC
AL A
UTH
OR
ITY'
S D
EFIN
ITIO
N O
F N
ATU
RAL
GR
OU
ND
LEVE
L, P
RIOR
TO
CONS
TRUC
TION
COM
MEN
CING
.[S
EE W
ARNI
NG N
OTES
ON
THE
FACE
OF
PLAN
FOR
MOR
E DE
TAIL
S]
ALAN
SUL
LIVAN
& A
SSOC
IATE
S P/
L HAS
NOT
CAR
RIED
OUT
A TI
TLE
SEAR
CH F
OR T
HIS
SURV
EY. C
HECK
DNR&
W F
OR E
ASEM
ENTS
AND
ENC
UMBR
ANCE
S.
RESP
ONSI
BILI
TY F
OR T
HE L
OCAT
ION
OF A
NY N
ON-V
ISIB
LE S
ERVI
CE
COM
PLET
ED A
FLO
OD S
EARC
H ON
THI
S PR
OPER
TY.
CHEC
K CO
UNCI
L FL
OO
D IN
FORM
ATIO
N.
Serv
ices
Sewe
rage
:St
orm
wate
r:W
ater
:El
ectri
city:
Tele
phon
e:G
as:
Yes (
Esta
blish
ed)
Yes (
To K
erb)
Yes
Yes (
Ove
rhea
d)Ye
s (Un
derg
roun
d)No
Road
:Bi
tum
enKe
rb:
Yes (
Mou
ntab
le)
Foot
path
:No
Floo
d Le
vel:
POTE
NTIA
L FL
OOD
INUN
DATI
ONCA
LL G
CCC
1300
366
659
FOR
REP
ORT
NOTE
S:* D
ischa
rge
waste
to ex
isting
conn
ectio
n poin
t* P
rovid
e sed
imen
t con
trol to
site
wher
e req
'd
* Mete
r box
pos
ition a
s per
exist
ing
* All d
imen
sions
to be
confi
rmed
on si
te* D
ischa
rge
storm
wate
r to e
xistin
g dis
char
ge p
oint
PROPOSED SITE PLANSCALE 1:200 SHEET 4 OF 21
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
RAI
N W
ATER
STOR
AGE
TANK
S IN
ACC
ORDA
NCE
WIT
H TH
E QU
EENS
LAND
DEV
ELOP
MENT
COD
E -
PART
4.2 &
4.3
MAND
ATOR
Y RA
INW
ATER
TANK
3000
L PER
DUP
LEX
UNIT
, 500
0L P
ER S
INGL
E DE
TACH
ED D
WEL
LING,
FOR
WC'
S,W
ASHI
NG M
ACHI
NE C
OLD
WAT
ER TA
PS &
EXT
ERNA
L TAP
S. LO
CATI
ON T
BC O
N SI
TE T
O PR
OVID
E TH
E LE
SSER
OF
100m
² OR
HALF
-ROO
F CA
TCHM
ENT A
REA,
WIT
H 15
LIT
RE F
IRST
FLU
SH D
IVER
SION
AS
PER
BUIL
DER.
AUT
OSW
ITCH
ING
DEVI
CE O
R TR
ICKL
E TO
P-UP
SYS
TEM
REQU
IRED
ATT
ACHE
D TO
TOW
N W
ATER
, WIT
H BA
CKFL
OWPR
EVEN
TION
DEV
ICE.
ALL
TAN
KS TO
BE
MIN
450m
m FR
OM S
IDE
OR R
EAR
BOUN
DARY
. TAN
KS O
VER
2.4M
HIGH
TO
BEMI
N 1.
5M F
ROM
SIDE
OR
REAR
BOU
NDAR
Y. R
ELAX
ATIO
N RE
QUIR
ED F
OR T
ANKS
IN 6
M FR
ONT
SETB
ACK.
OVE
RFLO
WTO
BE
CONN
ECTE
D TO
LEGA
L POI
NT O
F DI
SCHA
RGE.
**REFER TO SHEET 05 FOR SECOND STOREY SET BACKS**
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
5 21
06-18asw09-24aaw 12-06afg
12-2
1asw
12-1
5asw
09-0
6asw
720
820 820
720
720
820
820
06-18asw
06-24asw
900
hamp
er
12-0
9aaw
12-0
9aaw
12-0
9aaw
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
12-2
4asw
27-1
7afg
2046
6100
4839 12385
3139
5620
3795
11745
2006
18.2
0590
°43 '
00"
19.0
9527
0°43
'00 "
3 2 . 9 9 5 0°43 '00"
3 3 . 0 0 5179°10 '00 "
B A N K S I A B R O A D W
A Y
roof fall
D.PD.PD.PD.P
D.PD.P D.P
PROPOSED UPPER FLOOR SETBACK PLANSCALE 1:200 SHEET 5 OF 21
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
6 21
hamper
W.M.PROV T
REF.
20620
5950 14670
910 230 5610 70 3180 70510
70 3790 230
230 7250 70 2080 70 910 70 3760 230
230 5100 70 2210 110 3420 3530
5950 7720 6950
20620
1292
0
5640
7280
5640
230
2550
70460
7046
0 7031
4023
0
230
1510
7020
3070
3140
230
1292
0
8650
4040
230
700
4020
3930
230
5570
7025
5070
4200
230
230
2770
7027
3070
LOUNGE
STORE
L'DRY
DINING KITCHEN BATH
BED 1BED 2
BED 3
LIVING
CARPORTPATIO
EXISTING FLOOR PLANSCALE 1:100
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
7 21
24-0
6alw
24-0
6alw
24-0
6alw
820 820
820
820
820
24-3
0stac
ker
720
820
W.M
.PR
OV
1 2 3 4 5 6 7 8 9 10 11 12 13 14
T
REF.
DWPROV
REF.
D.PD.PD.PD.P
D.PD.P D.P
15930
1260 230 9175 70 4965 230
230 4000 6010 3000 1200 230
2305700 70 1970 70 530 230 3580 470 1820
1260 8800 5870
1292
0
5800
7120
5800
350
2040
350
4030
350
230
5570
7026
0014
040
8023
0
230
3400
7021
0070
6820
230
230
6820
230
350
5290
230
2350
1000
1300
600
7015
0023
0
5640
7280
1292
0
15930
70 155070
950 230
230
2380
7095
070
3000 1200
750 70 3315 900 230
7043
070 10
0023
0
A18
A18
B18
B18
C19
C19
D19
D19
Mech. vent PDR
350x470 brick pier
350x
350 6
0mm
polyf
oam
& stu
d pier
s
Door bycabinet maker
16x treads @ 260 each17 risers @ 183.5 eachto be confirmed on site bystair manufacturer/builder
Fram
ed &
rend
ered
hood
,1:1
00 fa
ll to o
utside
edge
Shelves to be confirmedon site by client
350x
350 6
0mm
polyf
oam
& stu
d pier
s
GARAGE
L'DRY
FW
24-4
8 Pan
elift d
oor
430 step down togarage FLRL 11.15
KITCHENubo
Shelves
PANTRY
ohc ohc
400 o'hang
ohc
FAMILY
DINING
ALFRESCO
24-52 Stacker
ENTRYcsd
BBQ
PORT
ICO
PATIO
FO
Up
FWPDR
Up 430
Up
Up
VOID over
LINE
N
2x sl
/ dr
Up
450-24 alw 450-24 alw 450-24 alw
NOTES:* All dimension, steps & levels to be confirmed on site* Lift off hinges to WC door* Provide GPO & cold water provisions to DW space* All external and internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Water pressure limited to 500KPa at the meter* All handrails to be 1000mm above finished floor level
FLOOR AREAS
LOWER LIVING AREA:UPPER LIVING AREA:GARAGE:ALFRESCO:PORTICO:PATIO:
TOTAL:
122.04 sq.m164.96 sq.m34.39 sq.m33.11 sq.m3.45 sq.m5.52 sq.m
363.47 sq.m39.13 sqs
LOWER FLOOR PLANSCALE 1:100
ELEVATIONS
43
21
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
8 21
06-18asw09-24aaw 12-06afg
12-2
1asw
12-1
5asw
09-0
6asw
720
820 820
720
720
820
820
06-18asw
06-24asw
900
hamp
er
12-0
9aaw
12-0
9aaw
12-0
9aaw
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
12-2
4asw
27-1
7afg
A18
A18
B18
B18
C19
C19
D19
D19
14510
160 14350
70 5270 70530 70 530
70 3500 70530
70 3500 70
70 5360 6980 70 1800 70
70 5050 70 3200 70 100070530 70 4150 70
70 5050 140 2560 70 1000 70 3500 70
160 5190 3770 3570 1820
14510
1253
5
600
1193
5
7049
0570
2600
7041
5070
7035
3570
2500
7020
0070
1180
7029
0070
7017
3370
1733
7025
0070
2650
7035
0070
7053
070
3705
7053
070
2230
7095
070
3500
70
600
4975
6960
1253
5
70 170070 560
70 1750 70
791
849
1000 high dwarf wallas per BCA 96 3.9.2
1000 high handrailas per BCA 96 3.9.2
Fram
ed &
rend
ered
hood
,1:1
00 fa
ll to o
utside
edge
Stramit Colorbond capping,1:100 fall to outside edge
Stramit Colorbond capping,1:100 fall to outside edge
Shelves bycabinet maker
Bulkhead
60mm
polyf
oam
frame
dou
t to 23
0 tota
l
MASTERBED
WIR
BED 2
BED 4BED 3
BATH
LOUNGE
VOIDFW
ROBE
ROBERO
BE
LINE
N
FWENS
STOR
E
Raked ceiling
15-1
5fro
sted a
lw
2x 45
0-21
afg 3x sl
/ dr
3x sl
/ dr
3x sl
/ dr
3x sl
/ dr
3x sl/ dr
fg panel
roof fall
Stra
mit C
olorb
ond
shee
tm
etal
roof
@ 1
0 de
g. p
itch
D.PD.PD.PD.P
Free
stan
ding
bath
D.PD.P D.P
NOTES:* All dimension, steps & levels to be confirmed on site* Lift off hinges to WC door* Provide GPO & cold water provisions to DW space* All external and internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Water pressure limited to 500KPa at the meter* All handrails to be 1000mm above finished floor level
FLOOR AREAS
LOWER LIVING AREA:UPPER LIVING AREA:GARAGE:ALFRESCO:PORTICO:PATIO:
TOTAL:
122.04 sq.m164.96 sq.m34.39 sq.m33.11 sq.m3.45 sq.m5.52 sq.m
363.47 sq.m39.13 sqs
UPPER FLOOR PLANSCALE 1:100
ELEVATIONS
43
21
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
9 21
A18
A18
B18
B18
C19
C19
D19
D19
Stramit Colobond fascias,gutters & downpipes
Stramit Colobond fascias,gutters & downpipes
Solar hot waterpanel, location T.B.C
by manufacturer
roof
fall
roof
fall
Stramit Colorbond sheetmetal roof @ 12 deg. pitch
Stramit Colorbond sheetmetal roof @ 12 deg. pitch
D.PD.PD.PD.P
D.PD.P D.P
NOTES:* All dimension, steps & levels to be confirmed on site* Lift off hinges to WC door* Provide GPO & cold water provisions to DW space* All external and internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Water pressure limited to 500KPa at the meter* All handrails to be 1000mm above finished floor level
UPPER FLOOR ROOF PLANSCALE 1:100
ELEVATIONS
43
21
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
10 21
430
2720
2720
3150
640640
350x350 60mmpolyfoam & stud piers
Powder coated aluminium framedwindows & sliding glass doors
Stramit ColorbondCustom Orb sheet roof
Stramit Colorbond fascias,gutters & downpipes
Render existing brickwork
Stramit Colorbond CustomOrb sheet roof @ 10 deg. pitch
Stramit Colorbond capping,1:100 fall to outside edgeHorizontal weathboards
as selected
Raked eaves
FLFL
FL FLCL CL
CL CL
eave o'hang eave o'hang
ELEVATION 1 1:100
2720
2720
640
640
640
Powder coated aluminium framedwindows & sliding glass doors
Stramit ColorbondCustom Orb sheet roof
Stramit Colorbond fascias,gutters & downpipes
Stramit Colorbond capping,1:100 fall to outside edge
Horizontal weathboardsas selected
Render existing brickwork
Stramit Colorbond CustomOrb sheet roof @ 10 deg. pitch
FL FL
FL FLCL CL
CL CL
eave o'hang
eave o'hang
eave o'hang
BBQ
12° pitch
ELEVATION 2 1:100
NOTES:* EAVE O'HANG DIMENSIONS INCLUDE 40MM FASCIA
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
11 21
2720
2720
640 640
350x350 60mmpolyfoam & stud piers
Powder coated aluminium framedwindows & sliding glass doors
Stramit ColorbondCustom Orb sheet roof
Stramit Colorbond fascias,gutters & downpipes
Render existing brickwork
Stramit Colorbond capping,1:100 fall to outside edge
Horizontal weathboardsas selected
FL FL
FL FLCL CL
CL CL
eave o'hang
fg
eave o'hang
ELEVATION 3 1:100
3150
2720
430
2720
640
640
640
1200
45030
0 450
Horizontal weathboardsas selected
Framed & rendered hood,1:100 fall to outside edge
350x350 60mmpolyfoam & stud piers
Powder coated aluminium framedwindows & sliding glass doors
Render existing brickwork
Stramit ColorbondCustom Orb sheet roof
Stramit Colorbond fascias,gutters & downpipes
Rendered 60mm polyfoamframed out to 230 total
Stramit Colorbond capping,1:100 fall to outside edge
Entry door as selected
FLFL
FL FLCL CL
CL CL
fg
fg
fg
eave o'hang
eave o'hang
eave o'hang12° pitch
ELEVATION 4 1:100 NOTES:* EAVE O'HANG DIMENSIONS INCLUDE 40MM FASCIA
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
12 21
24-0
6alw
24-0
6alw
24-0
6alw
820 820
820
820
820
24-3
0stac
ker
720
820
1 2 3 4 5 6 7 8 9 10 11 12 13 14
spp for remotecontrolled paneliftdoor two handsetssupplied
TV
P. P.
CLIENT WITH ELECTRICIANCONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE
P.
ELECTRICAL LEGEND
TV
CEILING FAN LIGHT
PHONE OUTLET
2 GLOBE FAN, HEAT, LIGHT
METER BOX
SINGLE GPO'S - 1050 OFF FLOOR
SINGLE GPO'S - 300 OFF FLOOR
DOUBLE GPO'S - 300 OFF FLOOR
TV ANTENNA POINT
EXHAUST FAN
FLUORESCENT LIGHT
PHONE OUTLET-300 OFF FLOOR
CEILING FAN
DOWN LIGHT
WALL LIGHT
SMOKE DETECTOR
FLOOD LIGHT
PENCIL SPOT
SPECIAL LIGHT
SWITCH POINTS @ 1350 OFF FLOOR
DOUBLE GPO'S - 1050 OFF FLOOR
CEILING LIGHT (BATTEN HOLD)
FP. FLUORESCENT PENCIL SPOT
LOWER ELECTRICAL PLANSCALE 1:100
80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES
NOTES:* EXISTING METER BOX LOCATION TO BE CONFIRMED
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
13 21
06-18asw09-24aaw 12-06afg
12-2
1asw
12-1
5asw
09-0
6asw
720
820 820
720
720
820
820
06-18asw
06-24asw
900
hamp
er
12-0
9aaw
12-0
9aaw
12-0
9aaw
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
12-2
4asw
27-1
7afg
TV
P.
P.
P.
TV
roof fall
UPPER ELECTRICAL PLANSCALE 1:100 CLIENT WITH ELECTRICIAN
CONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE
P.
ELECTRICAL LEGEND
TV
CEILING FAN LIGHT
PHONE OUTLET
2 GLOBE FAN, HEAT, LIGHT
METER BOX
SINGLE GPO'S - 1050 OFF FLOOR
SINGLE GPO'S - 300 OFF FLOOR
DOUBLE GPO'S - 300 OFF FLOOR
TV ANTENNA POINT
EXHAUST FAN
FLUORESCENT LIGHT
PHONE OUTLET-300 OFF FLOOR
CEILING FAN
DOWN LIGHT
WALL LIGHT
SMOKE DETECTOR
FLOOD LIGHT
PENCIL SPOT
SPECIAL LIGHT
SWITCH POINTS @ 1350 OFF FLOOR
DOUBLE GPO'S - 1050 OFF FLOOR
CEILING LIGHT (BATTEN HOLD)
FP. FLUORESCENT PENCIL SPOT
80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
14 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1000 3065 900 300
300
600
350x470 brick piers with1/M12 rod set into footingsas per engineers design
350x
350 e
ngag
ed b
rick p
iers
with
1/M12
rod p
er pi
er se
t into
footin
gs as
per e
ngine
ers d
esign
LB w
allLB
wall
LB w
all
270 bulkhead
Bulkhead dimensionsto be confirmed withcabinet makers details
LB po
int
LB po
int
MGP12/MGP15 TUAN PINEOR F27 HARDWOOD
max 1800 ctrsplate to lintel atstrap from topwide to have looped
@ each end
9.20( c )
( b )9.21
7500 Max
TO SLAB
ALL CONSTRUCTION SHALL BE NOT LESS THAN AS PRESCRIBED IN THE BUILDING ACT and THE BUILDING CODE of AUST. and A.S. 1684.2 - 1999.
TOP PLATELOADBEARING
TOP PLATENON-LOADBEARING
STUDSLOADBEARING
STUDSNON-LOADBEARING
NOGGING
JAMB STUDS
ROOF FRAMING
ROOF BATTENS
LINTELS & BEAMS
2/35 x 70 ( MGP12 )
35 x 70 ( MGP10 )
35 x 70 ( MGP10 )
70 x 35 ( MGP12 ) @ 450 CTS.
70 x 35 ( MGP10 ) @ 450 CTS.3000 MAX. HT.
35 x 70 ( MGP10 ) STAGGERED
2 COMMON FOR OPENING > 900
4 COMMON FOR OPENING > 3000
METAL BATTENS @ 900 cts
ENGINEER DESIGNED ROOF TRUSSES@ 600 CTS.
ROOF MATERIAL SHEET METAL ROOF
WALL FRAMING
( SEAS. PINE )
SEAS. PINE
ROOF BATTEN TOTRUSS / RAFTER
TRUSS / RAFTERTO TOP PLATE
TOP PLATE
TIMBER LIST
TIE DOWN FIXINGSFIXING OF
UPLIFTFORCE
FIGURENo
METHODTABLE
No OF FIXING
9.14 1.0 kN
9.13 3.3 kN
3 COMMON FOR OPENING > 2100
DIMENSION 'A'MAIN ROOF
DIMENSION 'A'GARAGE
1/ Framing ancor4/2.8 dia nails
9.9 kN9.13M12 rods cast into
windows > 1800mmslab @ 1800 ctrs
TYPE 17 SCREW1/75 mm No149.25
( d )
UPP. BOTTOM PLATELOW. BOTTOM PLATE
2/35 x 70 ( MGP10 )
N2/SR 70mmBR
ACIN
G RE
QUIR
ED
BRAC
ING
TO B
E CO
NFIR
MED
ON S
ITE
BY E
NGIN
EER
BRACING REQUIRED
88.61
kN
63.78 kN
LOWER BRACING PLANSCALE 1:100
TIMBER FRAME & TRUSSES2720mm PITCHING HEIGHT12 Deg ROOF PITCHCOLORBOND SHEET ROOF
and nailing at 50mm crs top and bottom
----------------------------
----------------------------
BRACING LEGEND
with anchor rods or with anchor bolts
TB4B Structural pine ply 7mm or F27 4mm 6 kN/m
----------------------------
TB1 Galvanised steel angle 1.5 kN/m
NOTE:* Provide three studs under each end ofTG's, provide four studs under each end ofGT's.* Hardwood top plate under GT's, TG's andunder loadbearing points.* Edge nailng of ply brace to be at 50mmcentres, no tiedown rods are required.* M12 rods to brick piers, typical, cavityfilled.* ALL 600mm TB4B panels to have an M12rod to each end.
N2/SR
BRACING TO BE CONFIRMEDON SITE BY ENGINEER
NOTES:* ALL LOWER FLOOR LINTELS AS PER ENGINEERS DESIGN* LOWER FLOOR BRACING AS PER ENGINEERS DESIGN* LOWER FLOOR WALLS TO BE RAISED TO A PITCHINGHEIGHT OF 2720mm
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
15 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
TB4B
0.9
TB4B
0.6
TB4B
0.6
TB4B
0.6
TB4B
0.9
TB4B
0.9
TB4B
0.9
TB4B
0.9
TB4B
0.9
TB4B 0.9 TB4B 0.9
TB4B 0.9
TB4B 0.9TB4B 0.9TB
4B 0
.9
12 de
g. ra
fters
as pe
ren
ginee
rs de
sign
Raked ceiling
Hamper between vanitywall and bulkhead
LB w
all
P.G.T
LB po
int
LB w
all
2/190x35 MGP12140x35MGP12
140x
35MG
P12 N
LB
140x
35MG
P12 N
LB
140x
35MG
P12 N
LB14
0x35
MGP1
2 NLB
140x
35MG
P12 N
LB19
0x35
MGP1
2 NLB
190x35 MGP12
190x
35 M
GP12
NLB
140x
35MG
P12 N
LB
190x35 MGP12
140x35MGP12 NLB
190x
35MG
P12 N
LB195x65 Hyne 17c
roof fall
MGP12/MGP15 TUAN PINEOR F27 HARDWOOD
max 1800 ctrsplate to lintel atstrap from topwide to have looped
@ each end
9.20( c )
( b )9.21
7500 Max
TO SLAB
ALL CONSTRUCTION SHALL BE NOT LESS THAN AS PRESCRIBED IN THE BUILDING ACT and THE BUILDING CODE of AUST. and A.S. 1684.2 - 1999.
TOP PLATELOADBEARING
TOP PLATENON-LOADBEARING
STUDSLOADBEARING
STUDSNON-LOADBEARING
NOGGING
JAMB STUDS
ROOF FRAMING
ROOF BATTENS
LINTELS & BEAMS
2/35 x 70 ( MGP12 )
35 x 70 ( MGP10 )
35 x 70 ( MGP10 )
70 x 35 ( MGP12 ) @ 450 CTS.
70 x 35 ( MGP10 ) @ 450 CTS.3000 MAX. HT.
35 x 70 ( MGP10 ) STAGGERED
2 COMMON FOR OPENING > 900
4 COMMON FOR OPENING > 3000
METAL BATTENS @ 900 cts
ENGINEER DESIGNED ROOF TRUSSES@ 600 CTS.
ROOF MATERIAL SHEET METAL ROOF
WALL FRAMING
( SEAS. PINE )
SEAS. PINE
ROOF BATTEN TOTRUSS / RAFTER
TRUSS / RAFTERTO TOP PLATE
TOP PLATE
TIMBER LIST
TIE DOWN FIXINGSFIXING OF
UPLIFTFORCE
FIGURENo
METHODTABLE
No OF FIXING
9.14 1.0 kN
9.13 3.3 kN
3 COMMON FOR OPENING > 2100
DIMENSION 'A'MAIN ROOF
DIMENSION 'A'GARAGE
1/ Framing ancor4/2.8 dia nails
9.9 kN9.13M12 rods cast into
windows > 1800mmslab @ 1800 ctrs
TYPE 17 SCREW1/75 mm No149.25
( d )
UPP. BOTTOM PLATELOW. BOTTOM PLATE
2/35 x 70 ( MGP10 )
N2/SR 70mm
TIMBER FRAME & TRUSSES2720mm PITCHING HEIGHT12 Deg ROOF PITCHCOLORBOND SHEET ROOF
and nailing at 50mm crs top and bottom
----------------------------
----------------------------
BRACING LEGEND
with anchor rods or with anchor bolts
TB4B Structural pine ply 7mm or F27 4mm 6 kN/m
----------------------------
TB1 Galvanised steel angle 1.5 kN/m
NOTE:* Provide three studs under each end ofTG's, provide four studs under each end ofGT's.* Hardwood top plate under GT's, TG's andunder loadbearing points.* Edge nailng of ply brace to be at 50mmcentres, no tiedown rods are required.* M12 rods to brick piers, typical, cavityfilled.* ALL 600mm TB4B panels to have an M12rod to each end.
N2/SRBR
ACIN
G RE
QUIR
EDBR
ACIN
G PR
OVID
ED
BRACING REQUIRED
45.43
kN48
.60 kN
26.02 kNBRACING PROVIDED 27.00 kN
UPPER BRACING PLANSCALE 1:100
NOTES:* TRUSS LAYOUT & LINTELS TO BE CONFIRMED BY TRUSSMANUFACTURER / ENGINEER* ANY REQUIRED ROOF STRAPPING AS PER ENGINEERS DESIGN* ALL INTERNAL LINTELS IN CEILING SPACE
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
16 21
1020 240
350
2040
350
4030
350
3580 470 1820
350
5290
5640
7120
1260 910
2870 5870
Top up slab to FLRL 11.58
Proposed concrete slab as perengineers design FLRL 11.58
Proposed concrete slab onbrick up base as perengineers design FLRL 11.48
fwtub
sink sink
wc
basin fw
Existing concrete slabFLRL 11.58
Existing concrete slab
FLRL 11.15
Extent of floor above
Exte
nt o
f floo
r abo
ve
Proposed concrete slab on brickup base as per engineers design
FLRL 11.48
SLAB LAYOUT PLANSCALE 1:100
NOTES:* SLABS & FOOTINGS AS PER ENGINEERS DESIGN* HOMEGUARD TERMITE TREATEMENT TO BE INSTALLED AS PERMANUFACTURERS SPECIFICATIONS & IN ACCORDANCE WITH AS 3660.1* ALL DIMENSIONS TO BE CONFIRMED WITH FLOOR PLAN DIMENSIONS* ALL HEIGHTS, STEPS & LEVELS TO BE CONFIRMED ON SITE* KEY NEW SLABS INTO EXISTING AS PER ENGINEERS DESIGN
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
17 21
24-0
6alw
24-0
6alw
24-0
6alw
820 820
820
820
820
24-3
0stac
ker
720
820
1500
1660
LB w
all
LB w
all
Conn
ectio
ns by
engin
eer
LB w
all
Bear
ers a
s per
engin
eer
Rafte
rs @
5 de
g. pit
chas
per e
ngine
ers d
esign
Conn
ectio
n as p
eren
ginee
rs de
sign
LB po
intLB po
int
Joist
s @ 4
50 C
RS a
spe
r eng
ineer
s des
ign
Joist
s @ 4
50 C
RS a
spe
r eng
ineer
s des
ign
Joist
s @ 4
50 C
RS a
spe
r eng
ineer
s des
ign
Joist
s @ 4
50 C
RS a
spe
r eng
ineer
s des
ignca
ntile
ver
joists
Bearers as per engineers design
Bear
ers a
s per
eng
ineer
s des
ign
cantileverbeam
Beam
as p
er e
ngine
ers d
esign
FLOOR JOIST PLANSCALE 1:100
NOTES:* BEARER & JOIST LAYOUT DIAGRAMATIC ONLY & TOBE CONFIRMED BY ENGINEER* BEARER & JOIST SIZES AS PER ENGINEERS DESIGN* ALL FIXINGS/CONNECTIONS AS PER ENGINEERS DESIGN
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
18 21
2720
2720
640
640
640
1000
12 deg. roof trusses @ 600 CRS asper truss manufacturers specifications
Stramit ColorbondCustom Orb sheet roof
Bearers & joists asper engineers design
Existing brickwork to be raisedto a pitching point of 2720
Existing brickwork to be raisedto a pitching point of 2720
Stramit Colorbond capping,1:100 fall to outside edge
HomeGuard termite protection system tounderside of slab, perimeter & penetrations,in accordance with AS 3660.1
16x treads @ 260 each17 risers @ 183.5 eachto be confirmed on site bystair manufacturer/builder
Proposed slab on brick upbase as per engineers design Existing slab on brick up base
Shelves to be confirmedon site by client
SECTION 1:100
18A
FL FL
FL FLCL CL
CL CLBINDERS @ 3000 CRS
eave o'hang
eave o'hang
eave o'hang
ALFRESCOBBQ
DINING
BED 2 BED 3
as per flashing detail sheet 20
2720
2720
480
640
640
1000
240
12 deg. roof trusses @ 600 CRS asper truss manufacturers specifications
Stramit ColorbondCustom Orb sheet roof
12 deg. rafters as perengineers design
Raked ceiling
Raked eaves
Framed & rendered hood,1:100 fall to outside edge
16x treads @ 260 each17 risers @ 183.5 eachto be confirmed on site bystair manufacturer/builder
Bearers & joists asper engineers design
Stramit Colorbond capping,1:100 fall to outside edge
Existing brickwork to be raisedto a pitching point of 2720
Existing slab on brick up base
Proposed slab on brick upbase as per engineers design
SECTION 1:100
18B
FL FL
FL FLCL CL
CL CLBINDERS @ 3000 CRS
eave o'hang
to stud wall
eave o'hang
ENTRYKITCHEN
BATH
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
19 21
430
2720
2720
3150
640
640
2525
12 deg. roof trusses @ 600 CRS asper truss manufacturers specifications
Stramit ColorbondCustom Orb sheet roof
Bearers & joists asper engineers design
Existing brickwork to be raisedto a pitching point of 2720
Stramit Colorbond capping,1:100 fall to outside edge
195x65 Hyne 17c
Hamper between vanitywall and bulkhead
Existing garage slab & footingsExisting slab on brick up base
SECTION 1:100
19C
FLFL
FLFLCLCL
CLCLBINDERS @ 3000 CRS
eave o'hang
eave o'hang
as per flashing detail sheet 20
DINING GARAGE
WIR ENS
430
2720
2720
3150
2720
480 640
640 12 deg. roof trusses @ 600 CRS asper truss manufacturers specifications
Stramit ColorbondCustom Orb sheet roof
Bearers & joists asper engineers design 10 deg. rafters as per
engineers design
Existing garage slab & footings Footings & slabs as perengineers design
HomeGuard termite protection system tounderside of slab, perimeter & penetrations,in accordance with AS 3660.1
Kek new slabs into existingas per engineersd design
Footings & slabs as perengineers design
Beam as perengineers design
BINDERS @ 3000 CRS
FLFL
FL FLCL CL
CL CL
GARAGEPDR ALFRESCO
BED 2WIRMASTER SUITE
eave o'hang
to stud wall
eave o'hang
SECTION 1:100
19D
As per flashing detail sheet 20
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers ofdiscrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DES
IGN
IS T
HE E
XCLU
SIVE
PRO
PERT
Y OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
SN.
B AL
L WRI
TTEN
DIM
ENSI
ONS
TAKE
PRE
CEDE
NCE
OVER
SCA
LED
SIZE
SBE
WAR
NED:
SUB
STIT
UTIO
N OF
ANY
STR
UCTU
RAL M
EMBE
RS, A
ND O
R AN
Y VA
RIAT
ION
TO A
NY P
ART O
F TH
E DE
SIGN
WILL
VOI
D AN
YRE
SPON
SIBI
LITIE
S OF
STU
ART
OSMA
N BU
ILDIN
G DE
SIGN
S FO
R TH
E ST
RUCT
URAL
INTE
GRIT
Y AN
D PE
RFOR
MANC
E OF
THE
BUI
LDIN
G
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
O'CONNOR
PROPOSED RESIDENCE40
BANKSIA BROADWAY,BURLEIGH WATERS
3724
MJ
A 13/01/2010
******
SO
CUSTOM
1:100 @ A3
20 21
2720
900
600
900
5027
0
1800
600
5027
0
KITCHEN DETAIL 2 1:50KITCHEN DETAIL 1 1:50
FL
CL
R'hood
spaceUBO
HPspaceREF
1000mm
Bulkhead
spaceDW
Sink
400mmmwspace
FLASHING DETAIL TYPICAL 1:20
Stramit Colorbond flashing to topof all BV walls continuous undergable end wall cladding
Selected cladding asnominated on elevations
Floor joists by engineer
450mm WIDE UNLESS OTHERWISE NOTED. TO BE 300mm WIDE & KITCHEN DRAWERS TO BE CABINETMAKERS DISCRETION, VANITY DRAWER* DOOR SWINGS & CUPB'DS CONFIGURATIONS TONOTE:
NOTE:2/30x0.8mm GI strap fixed to top plates & studs at each end with 4/2.8mmdiam nails.
External wall
Internal bracing wall
35mm gap to truss
Blocking pieces to both sidesof truss bottom chord fixed totop plate with 4/3.33 diam. nails
Bottom chord of truss
Bracing wall
1800 min. 2700 max.
50
150
300
30x2.8mm diam flathead nailsnail spacing as shown
2/50x2.8mm diam nails at each endand each stud
1:20
7025
0320
20
Timber architrave
timber lintel beam, as per
Min 10mm gap
Timber reveal
TYPICAL FIXING TO TOP OF BRACING WALL 1:20
TYPICAL METAL ANGLE BRACING (TB1)1.5kN/m 1:50
4mm F27 PLYWOOD BRACING (TB4B)6.0 kN/m (rods not required) 1:50
DETAIL 1 1:10
size as per bracing plan
150mm GI strapunder top ribbonplate.
Gap to trussend.diameter nails each3/75 x 3.33 mm
TRUSSES PARALLEL TO BRACING WALL 1:20
bridging piece90x35mm MPG12 timber
bracing wall
NOTE:2/30x0.8mm looped GI strap fixed over bridging piece & to underside of top platewith 4/2.8mm diam nails at each end of straps & to bridging piece.
30 degs max
30x0.8mm gal. strap3/30x2.8mm dia nails
to end of stud
Metal angle of Min.nominal section18x16x1.2mm
Max depth of notchnot to exceed 20mm
Note: if two or more panelare butted together thevertical join nailing is tobe @50mm centres.Single sheet vertical nailingto be @150mm centres.
Tie down to floor(nomial fixing only)
CANTELEVERED TRUSSES TO ACHIEVE600mm O'HANG WITH 25 deg ROOF PITCHWHERE 2440mm IS USED
or as
nomi
nated
or as
nomi
nated
waffle pod slab as per engineers designwith exposed edge for visual inspectionTermi-mesh or similar to all slab penetrations& perimeter
@ max 1800 centresfrom top plate to lintel
to have looped strapWindows > 1800 wide
sarking to roof where applicable
openings and corners, from top plate to slab.12mm Rods at 1800mm cts, each side of
or as nominated on plans
or as nominated on plans
as selected
as selected10mm plasterboard ceiling, paint finish
90mm cornice, paint finish as selected
timber architrave, as selected
aluminium framed window as selected
10mm plasterboard wall lining, paint finish
-D1
GI partition bracket
manufacturers printed specificationsRoof trusses @ 600mm centres as per truss
FL
CL
21° roof pitch
320
2120
2440
moisture barrier
50mm sand bed
dia' nails each end over trusses to top plateor 30 x 0.8mm GI strap with 3/2.8mmof trusses and top plates with 4/2.8 dia' nailsone framing anchor to be fixed to each end
Sheet metal roof with metal battens @900mm cts
600
metal fascia & gutter
TRUSSES PERP.TO BRACING WALL
T.B.C by engineer
TYPICAL TIMBER FRAME SECTION 1:20
WITNESS DATE
amendmentsdesign drawn by
date
scales
job number
of
Phone (07) 55 203 022Fax (07) 55 203 033PO Box 2845 Burleigh HeadsDC Qld 4220
ABN 73 097 995 616QLD 4219
BSA License No: 1129687Email: [email protected]
PLEASE READ CAREFULLY
IN THE INITAL AGREEMENT AND I UNDERSTAND CHANGESTHIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO
HEREAFTER MAY NOT BE POSSIBLE. THESE PLANSSUPERSEDE ALL OTHER PREVIOUS PLANS OR SKETCHES.
OWNER/S
Contractor to verify dimensions. Notify designers ofdiscrepancies. Failure to do
so shall void the designers responsibilities.
dimensions take preference.© Copyright reserved in part or whole. Written
THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES RESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING
BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANY
Address: 2/71 TownshipDrive, West Burleigh,
sheet #
checked byN2/SR/timber frame
NO SOFFITSWALL CLADDING ASNOMINATED ON PLANS
MJCUSTOM
3724O'CONNOR
40 BANKSIA BROADWAY,BURLEIGH WATERS A 13/01/2010
21211:100 @ A3
******SO