Click here to load reader

PRT-CTRL-DIN Protege GX Din Rail System Cell Backup Battery N+ N- NBNA +-V1+ V1+ V1+ V1+ V1+ V1+ V- V- V- V- V- V-Mains Input To other modules on network 8 PRT-CTRL-DIN Protege GX

  • View
    227

  • Download
    0

Embed Size (px)

Text of PRT-CTRL-DIN Protege GX Din Rail System Cell Backup Battery N+ N- NBNA +-V1+ V1+ V1+ V1+ V1+ V1+ V-...

  • PRT-

    CTR

    L-D

    IN

    Protege GX DIN Rail Integrated System Controller

    Installation Manual

  • 2 PRT-CTRL-DIN Protege GX DIN Rail Integrated System Controller Installation Manual | March 2012

    The specifications and descriptions of products and services contained in this document were correct at the time of printing. Integrated Control Technology Limited reserves the right to change specifications or withdraw products without notice. No part of this document may be reproduced, photocopied, or transmitted in any form or by any means (electronic or mechanical), for any purpose, without the express written permission of Integrated Control Technology Limited. Designed and manufactured by Integrated Control Technology Limited. Protege and the Protege Logo are registered trademarks of Integrated Control Technology Limited. All other brand or product names are trademarks or registered trademarks of their respective holders.

    Copyright Integrated Control Technology Limited 2003-2012. All rights reserved.

    Publication Date: March 2012

  • PRT-CTRL-DIN Protege GX DIN Rail Integrated System Controller Installation Manual | March 2012 3

    Contents

    1 Introduction _______________________________________________________________ 5

    1.1 Document Conventions ................................................................................................. 5

    2 Mounting _________________________________________________________________ 6

    2.1 Removal ......................................................................................................................... 6

    3 Connections ______________________________________________________________ 7

    3.1 Power Requirements ..................................................................................................... 7

    3.2 Encrypted Module Network ........................................................................................... 9

    3.3 Telephone Dialer .......................................................................................................... 10

    3.4 Ethernet 10/100 Network Interface ............................................................................. 11

    4 Configuration ____________________________________________________________ 12

    4.1 Setting the IP Address ................................................................................................. 12

    4.2 Setting the IP Address from a Keypad ........................................................................ 13

    4.3 Configuring a Controller via the Protege GX Software ................................................ 14

    Adding a Controller with Default Records ................................................................... 15

    Adding a Controller Based on an Existing Controller .................................................. 16

    Configuring a Controller .............................................................................................. 17

    4.4 Addressing Modules .................................................................................................... 23

    5 Door Access Control ______________________________________________________ 25

    5.1 Card Reader Connection ............................................................................................. 25

    5.2 Multiple Wiegand Card Reader Connection ................................................................ 26

    5.3 Door Contact Connection ........................................................................................... 27

    5.4 Lock Output Connection ............................................................................................. 28

    5.5 Programming the Onboard Reader ............................................................................. 29

    6 Inputs ___________________________________________________________________ 31

    6.1 Onboard Inputs ........................................................................................................... 31

    6.2 Resistor Value Options ................................................................................................ 32

    6.3 Trouble Inputs ............................................................................................................. 33

    7 Outputs _________________________________________________________________ 34

    7.1 Bell/Siren Output ......................................................................................................... 34

    7.2 Relay Outputs .............................................................................................................. 35

    7.3 Reader Outputs ........................................................................................................... 35

    8 Hardware Configuration ___________________________________________________ 36

    8.1 Defaulting a Controller ................................................................................................. 36

  • 4 PRT-CTRL-DIN Protege GX DIN Rail Integrated System Controller Installation Manual | March 2012

    9 LED Indicators ___________________________________________________________ 37

    9.1 Power Indicator ........................................................................................................... 37

    9.2 Status Indicator ........................................................................................................... 37

    9.3 Fault Indicator .............................................................................................................. 37

    9.4 Ethernet Link Indicator ................................................................................................ 38

    9.5 Modem Indicator ......................................................................................................... 38

    9.6 R1/R2 Reader Data Indicators .................................................................................... 38

    9.7 Bell Indicator................................................................................................................ 38

    9.8 Relay Indicators ........................................................................................................... 39

    9.9 Zone (Input) Indicators ................................................................................................ 39

    10 Mechanical Diagram ______________________________________________________ 40

    11 Mechanical Layout _______________________________________________________ 41

    12 Technical Specifications ___________________________________________________ 42

    12.1 Current and Validation Example .................................................................................. 43

    13 Ordering Information ______________________________________________________ 44

    14 Warranty ________________________________________________________________ 45

  • PRT-CTRL-DIN Protege GX DIN Rail Integrated System Controller Installation Manual | March 2012 5

    1 Introduction Thank you for purchasing the Protege GX DIN Rail Integrated System Controller by Integrated Control Technology. The Protege System is an advanced technology security system designed to provide integration with building automation, apartment complex control and HVAC in one flexible package. Communication is over a proprietary high speed protocol across an AES encrypted local area network and an encrypted proprietary RS-485 module network. Using modular-based hardware design, system installers have the flexibility to accommodate any installation whether it's small, large, residential or commercial.

    The Controller is the central processing unit of the Protege System. It communicates with all system modules, stores all configuration and transaction information, processes all system communication, and reports alarms and system activity to a monitoring station or remote computer.

    Flexible module network architecture allows large numbers of modules to be connected to the RS-485 Module Network. Up to 250 modules can be connected to the Protege System in any combination to the network up to a distance of 900M (3000ft). Communication beyond this distance requires the use of a RS-485 Network Extender

    The current features of the Protege GX DIN Rail Controller include:

    Internal industry standard 10/100 Ethernet 32 Bit advanced RISC processor with 2Gb total memory 8 high security monitored inputs NIST Certified AES 128, 192 and 256 Bit Encryption

    When receiving the DIN Rail Controller you should find the kit contains the items listed below. Please note that if you do not have the correct contents, you should contact your distributor immediately.

    Protege GX DIN Rail Integrated System Controller Protege GX DIN Rail Integrated System Controller Quick Start Guide 18 1K ohm resistors 1 330 Ohm EOL Termination Resistor 1 Diode 1N4007 1A 400V (Axial) DIN Rail Mounting Strip

    For more information on the Protege GX DIN Rail Integrated System Controller and other Integrated Control Technology products please login to www.incontrol.co.nz.

    1.1 Document Conventions

    Indicates a warning or cautionary message

    Indicates an important note or advisory information

    Indicates a hint or suggestion

    [TEXT] Bold text enclosed in brackets is used to show a section number or address of a programmable option or information on programming shortcut sequences

    i

  • 6 PRT-CTRL-DIN Protege GX DIN Rail Integrated System Controller Installation Manual | March 2012

    2 Mounting The Protege DIN Rail Controller is supplied as a DIN Rail mount module and is designed to mount on standard

Search related