25
PWR Airborne Tritium & Review of RG 1.21 data S. Sandike June 2014 EnvoNuTek, llc

PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

PWR Airborne Tritium&

Review of RG 1.21 data

S. Sandike June 2014 EnvoNuTek, llc

Page 2: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

PWR Tritium Production, Review

Tritium is produced primarily from neutroncapture by B-10 in a PWR.

Boric acid is added to PWR reactor coolantsystem (RCS) as a soluble reactivity shim.

Boron (enriched in B-10) is used in PWRfuel assemblies as a burnable poison.

Page 3: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

PWR Tritium ProductionNeutron capture by B-10 has several results:

. 5B10 + 0n1 -> [5B11]* ----> 3Li7 + 2He4

5B10 + 0n1 -> [5B11]* ----> 1H3 + 2(2He4)

Lithium is used in PWR Reactor Coolant pHcontrol, to balance the effect of the chemical shim.

Tritium production is primarily from B-10 in thespent fuel pools, ventilated out through monitoringequipment, to the main plant vent.

Page 4: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

PWR Tritium ProductionApprox 90% of the total tritium in PWRreactor coolant is produced in the coolant bythe soluble boric acid reactivity shim.The remaining 10% is produced by ternaryfission, B-10 burnable poisons, Li-6 neutroncapture, and deuterium activation.BWR tritium production is significantly lowerthan PWR due to absence of boric acid inthe coolant.

Page 5: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Industry Trend – Increased Airborne H-3

PWR Tritium Production hasincreased over the last decade due to24 month cycles and power uprates.

Increased boron causes an increasein tritium and ternary fission

Page 6: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Converting Liquid H-3 to Airborne

A few sites still use boric acid evaporators orotherwise attempt to eliminate liquid waste,and convert liquid H-3 to airborne effluent.

These plants are outliers in comparison toother PWRs, where the airborne H-3 curiesare defined primarily by the size and uCi/mlof H-3 in the Spent Fuel Pools.

Page 7: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Spent Fuel Pool H-3Increases with plant age (mixing during RFO)

Can sharply increase during re-rack or ISFSIoperation.

Careless addition of RCS to the pool can have avery significant and long lasting effect on totalpool H-3 inventory.

Ventilation systems are designed to sweep thepool and remove H-3 as water evaporates.

Page 8: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Factors effecting quantification ofAirborne Tritium in PWRs

NUREG 1301 allows batch sampling, once per month,and has a questionable LLD of 1E-6 uCi/cc.

There is an assumption that ventilation is in fact,continuously in place.

Any method of Airborne H-3 monitoring includesnumerous opportunities for very real (perhaps likely)error traps.

Sample collection methods differ between batch (coldtrap or bubbler) and continuous (silica gel).

Page 9: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

What can be done to improveairborne H-3 quantification?

Unlike most other processes, airborne H-3 effluent canbe assessed with relatively easy mass balances of thepool inventory.

Most plants have pool level instrumentation, or at leastlogs that identify when water is added to the pool.

Because ~90% of PWR airborne H-3 is from the pool,careful collection of this data can provide a way to verifyintegrated releases of H-3 determined from sampling.

Comparison of these two processes can confirm yoursampling technique, or tell you there is work to be done.

Page 10: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Typical SPF activity over a few cycles

0.0E+00

1.0E-02

2.0E-02

3.0E-02

4.0E-02

5.0E-02

1.0E-05

1.0E-04

1.0E-03

1.0E-02

1.0E-01

1.0E+00

1.0E+01

1.0E+02

06/19/05 04/15/06 02/09/07 12/06/07 10/01/08 07/28/09 05/24/10 03/20/11 01/14/12 11/09/12 09/05/13 07/02/14 04/28/15

Unit 2 Spent Fuel Pool RadiochemistrygammauCi/ml

H-3uCi/mlgamma

uCi/ml H-3uCi/ml

Page 11: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Simple MethodDuring a period of relative inactivity in the pool, simplymultiply liquid concentration at start and end, by therelatively constant volume of the pool.

The difference in curies should make up about 90% (ormore) of the quantified airborne H-3 determined fromplant vent sampling, unless there are numerous RCSleaks in containment or the aux building.

Simply choose a long enough period, without RFO, re-racking, or ISFSI operation, to give you good statistics,and determine, for example, a monthly average value.

Compare mass balance curies to the value obtainedfrom your chosen sampling technique.

Page 12: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

More Detailed MethodObtain detailed information regarding precise volumesof water added to the pool (from Ops or Eng).

– This may involve SOP changes for Ops Watch-Standers, sothey know to forward this info immediately to Chemistry, and/orto log the information so as not to miss any addition.

Again, over a period of no disruption in the pool, thetotal volume of water added should approximate themass that has been evaporated over the period.

Obtain an average concentration of the pool activityover this period (or integrate this effort with pool activityas it decreases) to determine the total curies released.

Compare results with quantification from sampling.

Page 13: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

What if results are not pretty?

A significant and repeated disparity in thequantified H-3 released from sampling andfrom pool mass balances should initiate aninvestigation.

First, be sure there wasn’t a valid reason forthe disparity (SFP operation, changingsource term, re-racking, etc).

Page 14: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Some causes for a disparityQuantification with Silica Gel, although continuous,is cumbersome, time-consuming, expensive, andcan be just as inaccurate as batch sampling due tohandling, weighing, distilling, etc.While batch sampling once/month is allowed, thisclearly assumes a relatively constant release rateup the vent.– Is that the case? How do you know?

Non-continuous (intermittent) use of the FuelStorage Building ventilation system cansignificantly skew this balance!

Page 15: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Intermittent FSB ventilation

GDC states that the ventilation system isalways running during normal plant ops.

Are replacement fans available?

What happens when the fan is “run tofailure”?

Does station management imagine thatrunning the exhaust fan is “optional”?

Page 16: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

An attempt to quantify H-3 releases from a FSB without ventilation

Page 17: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

“It’s too cold in here”A possible scenario in the north: a less-than-carefullyevaluated decision by a watch-stander results in turningoff the exhaust fan when it’s cold outside.

It is common to use plant steam in coils at the supply fanplenum to heat the Fuel Storage Building during winter.These coils often lack PMs and eventually leak due tothe pH control in plant steam, or just due to neglect.

To avoid water pouring over the floor, these broken coilsare then sometimes isolated, leaving no means oftemperature control in the building.

An enterprising young NPO then mistakes the exhaustfan ON/OFF switch for a thermostat, and secures theexhaust fan to keep the building more “comfortable”.

Page 18: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

100% Humidity is rarely comfortable

It’s also not entirely per design specification.

“Storing” airborne H-3 in this water vapor over thepool results in loss of control of effluents, andpossible issues with “failure to survey”.

Typically, this kind of operation can also lead toenhanced local re-condensation as H-3 escapesout the supply or exhaust plenum (or any otherholes) at ground level. It then re-appears in localstorm drains. A real pain to monitor.

Page 19: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

(Per Reactor)

Page 20: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Comparison of RG 1.21 H-3

Can’t really make any conclusions without knowingoperational objectives, pool size, status of fuel,concentration in the pool, many other parameters.

But we CAN recognize that this data is very widelyscattered and deserves some verification.

It can and should be verified independently at eachfacility with your own specifics, using spent fuelpool mass balance testing.

Page 21: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Curies of Airborne H-3 released

Ruling out the ultra high (convertingliquid to airborne) and the ultra low(shutdown and/or defueled), aGaussian distribution (almost) emergesaround 20-40 curies of airborne tritiumper year, per reactor, based onobservations of 2012 only.

Page 22: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Your reported airborne curiesThe previous slides of industry comparison do not suggestyour numbers are wrong or right.

However, given the spread of this data and the likelihood oferror and variability in sampling, it may be more than justbeneficial to verify your H-3 determination with a spent fuelpool mass balance, at least periodically.

Especially true if you– 1) are an outlier with curies,– 2) suspect trouble with FSB ventilation, or– 3) suspect batch sampling to be less than totally representative.

Page 23: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Example of simple balanceH-3 Loss to Evaporation Calculation

Voume of pool: 280,000 gallons

Activity start: Activity end Activity lost

uCi/ml uCi/ml Curies

Cycle 21 4.20E-02 1.80E-02 25.4

Cycle 20 4.72E-02 2.22E-02 26.5

Cycle 19 5.26E-02 2.29E-02 31.5

Cycle 18 4.93E-02 2.24E-02 28.5

Additional rigor can be added as necessary for half life correction, etc.

Page 24: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

Addition rate to pool methodAddDate

inchesadded

DeltaDays

gallonsPW added

SFP H-3uCi/cc

Ci H-3lost

01-03-07 6 16 3659 3.80E-02 0.52601-15-07 5 12 3049 3.80E-02 0.43901-29-07 6 14 3659 3.38E-02 0.46802-05-07 6 7 3659 3.38E-02 0.46802-12-07 5 7 3049 3.31E-02 0.38202-26-07 5 14 3049 3.32E-02 0.38303-03-07 6 5 3659 3.32E-02 0.46003-13-07 4 10 2439 3.21E-02 0.29603-20-07 6 7 3659 3.21E-02 0.44503-27-07 5 7 3049 3.21E-02 0.37004-04-07 6 8 3659 3.12E-02 0.43204-15-07 5 11 3049 3.12E-02 0.36004-22-07 6 7 3659 3.12E-02 0.43205-04-07 4 12 2439 3.02E-02 0.27905-14-07 6 10 3659 3.02E-02 0.418

This method involves knowing a conversion from inches to gallons withregard to pool level. Some facilities have pool level in the plant computer.

Page 25: PWR Airborne Tritium Review of RG 1.21 datahps.ne.uiuc.edu/rets-remp/PastWorkshops/2014/Thu_09-2... · 2014. 6. 12. · Curies of Airborne H-3 released Ruling out the ultra high (converting

BenefitsThis kind of self assessment is beneficial forunderstanding your processes, as well as withregard to regulatory compliance and inspections.

You may discover that your chosen samplingregime is flawed, and are under or over reportingtritium effluent.

You may also determine that you may have alarger issue with escaping H-3 or leaks,heretofore, unknown.