Upload
doque
View
246
Download
2
Embed Size (px)
Citation preview
QPC-CH CCS AC63
TRI RAPID CHARGER – INSTRUCTION MANUAL
This document is copyrighted, 2014 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves the right to make improvements to the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of the original manufacturer. Information provided in this manual is intended to be accurate and reliable. However, the original manufacturer assumes no responsibility for its use, or for any infringements upon the rights of third parties that may result from its use. All other product names or trademarks are properties of their respective owners.
User manual version
V1.0.1
September edition 2014
Platform version V2.0
CirCarLife version V4.3
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 1 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
CONTENTS
1 INTRODUCTION ................................................................................................................... 3
1.1 CERTIFICATIONS......................................................................................................... 3
1.2 SECURITY WARNINGS ................................................................................................ 4
1.3 IMPORTANT SAFETY INFORMATION ........................................................................ 5
2 BASICS ................................................................................................................................. 6
2.1 CHARGING MODES ..................................................................................................... 6
2.2 PLUG TYPES ................................................................................................................ 7
3 QUICK CHARGER AT A GLANCE ...................................................................................... 8
3.1 FEATURES ................................................................................................................... 8
3.2 UNIT OVERVIEW .......................................................................................................... 9
3.3 USER FRONT PANEL ................................................................................................. 10
3.4 COLOUR CODE OF THE CHARGER BEACONS ....................................................... 11
3.5 CHARGE POINT PLUGS ............................................................................................ 12
4 INSTRUCTIONS FOR USE ................................................................................................ 13
4.1 CHARGING INFORMATION SCREEN ....................................................................... 14
4.2 CHARGING SUMMARY SCREEN .............................................................................. 15
5 EMERGENCY STOP........................................................................................................... 16
6 SETTING UP THE UNIT ..................................................................................................... 17
6.1 PREREQUISITES ....................................................................................................... 17
6.2 NETWORK TOPOLOGY ............................................................................................. 18
6.3 LAN CONNECTION PROCEDURE ............................................................................. 19
6.4 SETUP WEB PAGE ..................................................................................................... 23
6.4.1 NETWORK SETUP ............................................................................................. 24
6.4.2 PUBLIC ADDRESS MANAGER .......................................................................... 25
6.4.3 LOCALE SETUP ................................................................................................. 25
6.4.4 TIME SETUP ....................................................................................................... 26
6.4.5 SECURITY SETUP ............................................................................................. 27
6.4.6 SYSTEM INFORMATION.................................................................................... 28
6.5 LOG WEB PAGE ......................................................................................................... 30
7 QUICK CHARGER OCPP INTEGRATION ........................................................................ 31
7.1 INTEGRATION SETUP WEB PAGE ........................................................................... 31
7.2 OCPP ENGINE SETUP WEB PAGE ........................................................................... 32
7.2.1 APPLICATION PARAMETERS ........................................................................... 33
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 2 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.2 POWERSTUDIO ENGINE................................................................................... 34
7.2.3 CHARGE BOX (CB) ............................................................................................ 35
7.2.4 OCPP SETTINGS ............................................................................................... 36
7.2.5 MANAGEMENT SYSTEM (CS) .......................................................................... 38
7.2.6 SSL CERTIFICATES ........................................................................................... 39
7.2.7 ACTIONS ............................................................................................................. 39
7.2.8 LOGS ................................................................................................................... 40
7.3 STEP BY STEP INTEGRATIONS PROCEDURE ....................................................... 41
8 URL SUMMARY TABLE .................................................................................................... 43
9 CHARGE STATION MONITORING .................................................................................... 44
9.1 DEFAULT FACTORY CREDENTIALS ........................................................................ 44
9.2 CIRCARLIFE CLIENT SOFTWARE ............................................................................ 45
9.3 WEB BROWSER ......................................................................................................... 47
10 CIRCARLIFE SCADA CLIENT OVERVIEW ...................................................................... 48
10.1 MENU BAR .................................................................................................................. 49
10.1.1 OPTIONS MENU ................................................................................................. 49
10.1.2 VIEWS MENU ..................................................................................................... 50
10.1.3 GENERAL MENU ................................................................................................ 51
10.2 TOOLBAR ................................................................................................................... 52
10.2.1 TOOLBAR SETUP MENU ................................................................................... 53
10.3 STATUS BAR .............................................................................................................. 53
11 APPENDIX A: SCADA SOFTWARE FEATURES ............................................................. 55
11.1 SCADA DEVICES STATUS ........................................................................................ 55
11.1.1 VIEW SELECTION .............................................................................................. 56
11.1.2 DISPLAYING REALTIME DEVICES ................................................................... 56
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 3 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
1 INTRODUCTION
This manual contains all the information necessary for safe use of quick charge point
and helping to get the best performance results.
Circontrol’s quick charging stations are the fastest way of charging today’s electric
vehicles. Their innovative, original design offers a fast, easy to use charging solution, in
line with CHAdeMO’s current standards for the quick, direct current charging of electric
vehicles. This solution has a user friendly interface, vandal proof design and easy to
install structure. Communications has been integrated in all models allowing remote
controlling of the units, remote monitoring in real time and OCPP or XML integrations.
This feature provides an easy way to integrate in higher systems allowing owner to
take profit of it.
1.1 CERTIFICATIONS
Certification
Complies with IEC 61851, Electric vehicle conductive charging system (IEC 61851-
1 and IEC 61851-23)
Complies with IEC 62196, Plugs, socket-outlets, vehicle couplers and vehicle inlets
- Electric vehicle. conductive charging system (IEC 62196-1 and IEC 62196-3)
Complies with CHAdeMO protocol.
Complies with European Directive 1999/5/EC.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 4 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
1.2 SECURITY WARNINGS
THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT SAFETY
INFORMATION IN THIS DOCUMENT
The unit must be disconnected from any power source before
performing any maintenance (repairing or handling of any
equipment connections) and wait minimum 15 minutes
while capacitors are being discharged.
Do not modify the unit. If modified, CIRCONTROL will reject
all responsibility and the warranty will be void.
WARNING
People who use electronic medical devices such as
implanted cardiac pacemaker or implantable
cardioverterdefibrillator
(ICD) might be affected by electric wave from the
quick charger. Keep the device away from the quick
charger more than 2 meters while is in charge
operation.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 5 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
1.3 IMPORTANT SAFETY INFORMATION
Read all the instructions before using or configuring this product.
Do not use cables there are not in perfect conditions.
Do not use this unit for anything other than electric vehicle charging.
Do not modify this unit. If modified, Circontrol will reject all responsibility and the
warranty will be void.
Comply strictly with current safety regulations according to your country rules.
Do not make repairs or manipulations with the unit energised.
Only trained and qualified personnel should have access to low-voltage
electrical parts inside the device.
Check the installation annually by qualified technician.
Replace from service any item that has a fault that could be dangerous for
users (broken plugs, caps that don’t close...).
Use only original supplied spare parts.
Do not use this product if the enclosure or the EV connector is broken, cracked,
open, or shows any other indication of damage
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 6 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
2 BASICS
The EV charging process is regulated by the IEC 61851 and IEC 62196 international
standard regulations. These standards define the different charging modes and the
connector type required to recharge the EVs.
Below information shows different charging modes and plug types available in the
electric vehicles and charge points.
2.1 CHARGING MODES
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 7 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
2.2 PLUG TYPES
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 8 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
3 QUICK CHARGER AT A GLANCE
3.1 FEATURES
HMI: 8” screen provides to user all the detailed information of the charge
(energy charged, battery status…) and detailed procedures to start/stop
charging.
RFID: Authentication for start/stop charging transactions and also prepayment
options available to use with Circontrol RFID cards.
User management: provides a database to associate users with one or more
RFID cards to allow or deny recharges.
Connector Lock: Plug connector used (mode 3 and mode 4) has a lock
system to avoid disconnection of electric vehicle while is charging.
Light beacon: Three colour led indicates to user status of the charge point:
o Green: Available
o Blue: Charging
o Red: Error
Ethernet: TCP/IP communication through an “Ethernet” compliant network
between the charge point and customer network (if available).
3G and GPRS (optional) for remote control, monitoring or OCPP integrations.
Energy metering: Integrated meter built is measuring power and energy
consumed by the EV during a charge.
Real time monitoring: Using standard browser system allows access to the
unit and monitoring charge status.
Remote control: Remote actions as start/stop charge are available.
Charge data storage: System is capable to generate energy reports according
to data storage from recharging historic.
OCPP integration: OCPP is the Open Charge Point Protocol communication
between charge points and a central system allowing a centralization
authentication, monitoring in real time and a wide variety of functions related to
recharge.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 9 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
3.2 UNIT OVERVIEW
1. AC Plug beacons 2. DC Plug beacons 3. Air output cover
4. Air filter cover 5. MCB and RCB cover access
1 2
4 5
3
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 10 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
3.3 USER FRONT PANEL
AC PLUG + DC PLUG
1. 8” HMI 2. RFID reader 3. AC Plug – Control buttons
4. Emergency Push-Button 5. DC Plug – Control buttons
1 2
4 3 5
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 11 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
3.4 COLOUR CODE OF THE CHARGER BEACONS
Charge point is equipped with LED beacons at the top of the unit in order to indicate
the different states from each plug.
The following table shows all possible states of the beacons in the charge point:
STATUS COLOUR DESCRIPTION
1. AVAILABLE GREEN
The unit is available to begin a new recharging session.
2. CHARGING BLUE
The unit is occupied by a user that is currently charging a vehicle.
3. ERROR RED
The unit indicates:
- A malfunction in the unit. - Emergency button is pushed.
In both cases the charge point indicating this state is out of the service and the unit cannot be used until the incident is resolved.
RGB led beacons
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 12 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
3.5 CHARGE POINT PLUGS
Tri rapid charger is equipped with three different plugs:
AC (Mode 3): Type 2 – Semi fast charge.
DC (Mode 4): CHAdeMO or Combo 2. Ultra-fast charge.
Screen is split down the middle into two parts. Left side explains AC information and
right side explains DC information.
Please read following considerations before start using the unit:
Tri rapid charger can only carry out two simultaneous recharge sessions using
different RFID cards to start (AC + DC).
Charge point is not capable of carrying CHADEMO and Combo 2
simultaneously. Only one plug (CHAdeMO or Combo 2) can be used in DC.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 13 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
4 INSTRUCTIONS FOR USE
This section describes how to starting or ending a recharge session when only one DC
outlet is installed on the rapid charger for electric vehicles.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 14 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
4.1 CHARGING INFORMATION SCREEN
Image below appears when two electric vehicles are charging on the charge point
using AC and DC plug simultaneously.
AC PLUG INFORMATION
Option Description
Energy charged Real time energy supplied to the vehicle connected.
Charge time Recharging elapsed time.
Additional information Current status charging and how to stop it.
DC PLUG INFORMATION
Energy charged Real time energy supplied to the vehicle connected.
Maximum charging time
remaining
Maximum estimated time to complete vehicle recharging.
Battery status Battery current status.
Additional information Current status charging and how to stop it.
5
4
3
1
5
2
1
AC PLUG INFORMATION DC PLUG INFORMATION
1
5
3
4
1
2
5
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 15 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
4.2 CHARGING SUMMARY SCREEN
Image below appears when electric vehicles have finished to charge or charging in
progress has been interrupted by the user.
AC PLUG INFORMATION
Option Description
Energy charged Total energy supplied to the electric vehicle connected.
Charge time Total recharging elapsed time.
DC PLUG INFORMATION
Energy charged Total energy supplied to the electric vehicle connected.
Battery status Battery current status.
NOTE: This screen is displayed for 1 minute after recharge is completed or stopped.
DC PLUG INFORMATION AC PLUG INFORMATION
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 16 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
5 EMERGENCY STOP
The charge point is equipped with an emergency stop button to provide safety to the
people and the unit.
Emergency stop button is a function that is initiated by a human action and it is
intended to shut down equipment in case of emergency. Do not press if there is no
emergency or risk.
When the emergency stop is active in the unit:
All active recharges will stop.
LED beacon turns red.
Charge point cannot be used until rearm.
INSTRUCTION TO REARM THE CHARGE POINT
1- Release the emergency button.
2- Press stop button until the LED beacons turns green (20 seconds approx.)
3- Unit returns to display the idle state.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 17 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6 SETTING UP THE UNIT
Charge station can be configured and monitorized to establish owner preferences or
specific setup using integrated Ethernet communication port allocated in HMI controller
device.
Once service PC is configured as bellow procedure and connection established with
the charge station, direct access to the device main setup page will be showed.
Charge station is shipped from the factory with default network setting of “DHCP
enabled”. It means that the charge station will try to obtain an IP address from a DHCP
server available on the network.
Step by step below guide detailed setup an IP address to the charging station in case
there is no DHCP server available on the network.
6.1 PREREQUISITES
Below table shows, hardware and software needed to setup and IP address to the
charge station.
Computer running one of the following
operating systems
- Windows XP (x86)
- Windows Vista (x86/x64)
- Windows 7 (x86/x64)
- Windows 8 (x86/x64)
Crossover Cable UTP Cat.5e o Cat6
Software needed: IPSetup.exe.
(Supplied with charge point)
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 18 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.2 NETWORK TOPOLOGY
Connecting pc with charge station needs to be done with static IP address and TCP/IP
v4 protocol. Next section shows how to do this configuration.
Below figure shows Ethernet connection topology and the IP addresses used in this
guide as example.
IP: 192.168.1.11
NETMASK: 255.255.255.0IP: 192.168.1.10
NETMASK: 255.255.255.0
Crossover UTP
cable
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 19 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.3 LAN CONNECTION PROCEDURE
This section provides a step-by-step guide to be able to connect a laptop to the charge
station in order to see real-time status.
Step Actions
1
Click on the network icon next to the clock of the taskbar.
Click on “Open Network and Sharing Center”
2
On the left pane, click the option: “Change adapter settings”.
3
Right click on “Local Area Connection” and then click on “Properties”
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 20 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
4
Select “Internet Protocol Version 4 (TCP/IP)” option and click “Properties”.
5
Setup IP address and subnet mask like as shown below:
Click OK twice to complete the process to assigning IP address to the
computer.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 21 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7
Execute IPSetup.exe utility.
8
Enter the following parameters:
MAC of the charge point device (see lateral label in the device)
IP address: i.e.(192.168.1.11)
Netmask: i.e. (255.255.255.0)
Gateway: leave default settings.
10
Wait 30 seconds approximately until the process is complete.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 22 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
11
The process will complete when the following message appears.
If the message shown is the next one, check the following parameters.
- Check IP address entered.
- Check the MAC of the device entered.
- Try with another UTP CAT5e cable.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 23 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4 SETUP WEB PAGE
Setup web page allows managing networking setup, modem 3G setup, upgrading the
device and other options.
To access to the setup web page, open a web browser and enter the following
address:
Direct link: http://”IP ADDRESS”/html/setup.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 24 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.1 NETWORK SETUP
This section provides the basic configuration of the network parameters.
Value Description
Host name Name of the device on the network
DHCP Enable or disable the IP address
assignment by a DHCP server.
DHCP Client ID Client ID associated to the DHCP Server
(If available)
Address IP address assigned to the WallBox
Netmask Netmask of the network
Gateway Gateway/router IP address
Primary DNS server DNS server IP addresses
Secondary DNS server
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 25 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.2 PUBLIC ADDRESS MANAGER
This section is only for OCPP integrations and allows setting the IP address to
establish connection between charge point and OCPP central system.
Value Description
Address type Local address: When selected, private IP
address will be sent to OCPP central
system. This option is valid if the OCPP
central system is connected to the same
private network of the charge point.
Static address: When selected, enter a
value on Public IP textbox. It is possible to
enter an IP address or a domain name.
SIERRA Wireless Raven XE H2295EW:
Select this option only when SIERRA
Wireless RAVEN XE router 3G is
installed.
6.4.3 LOCALE SETUP
This section allows changing the language on the LCD screen.
Value Description
Currency Allows selecting the country currency
according to your country.
Language Allows selecting the screen unit language.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 26 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.4 TIME SETUP
This section allows setting the time and region unit time.
Value Description
Primary NTP Server Allows synchronizing time through
internet automatically Secondary NTP Server
Time zone Allows selecting the regional unit time
according to your country.
Time Actual date and time of the unit.
This button allows synchronizing date
and time with local computer connected
if the date and time of the charge point
is not correct.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 27 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.5 SECURITY SETUP
All of these parameters are disabled by default. When enabled, it denies unauthorized
access to the web page configuration (setup.html) of the device and also prevents the
export or import of a new configuration of PowerStudio engine from an unauthorized
user.
Value Description
Password ON: authentication enabled
OFF: authentication disabled
Username
Username and password authentication for setup.html web
page. New password
Password
Do not forget the credentials of the device. There is no way to reset the
device to default factory settings.
It will require returning the unit to the service centre.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 28 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.6 SYSTEM INFORMATION
This section provides basically information about the unit.
Value Description
MAC Identifier of the network card of the unit
Version Upgrade Version of the firmware currently installed
and link to the upgrade web page
PowerStudio version PowerStudio Engine version
Devices status Link that allows viewing the status of the
configured devices.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 29 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.6.1 SYSTEM UPGRADE
Upgrade web page allows to upgrade the firmware of the unit through a file with
*.upgrade extension.
This file is provided by your installer or manufacturer of the unit.
6.4.6.2 POWERSTUDIO VERSION WEB PAGE
Powerstudio version web page allows viewing the following information:
Current firmware version installed.
Scada Platform version
Available languages
List of available devices that can communicate with the WallBox.
Direct link: http://”IP_ADDRESS”/services/system/info.html
Firmware file transfer must not be interrupted. Failure of the file transfer involves
irreversible damage to HMI master controller and the correct functionality of the
equipment. It will require returning the unit to service centre.
Ensure that the unit will not be affected or powered off while updating.
Direct link: http://”IP_ADDRESS”/html/upgrade.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 30 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6.4.6.3 DEVICES STATUS WEB PAGE
Devices status web page allows checking if all devices configured with CirCarLife
Scada Editor 4.0 Software are available and working properly.
6.5 LOG WEB PAGE
Log web page allows showing a temporary log since CHADEMO is powered ON. If
CHADEMO has
Direct link: http://”IP_ADDRESS”/html/log
Direct link: http://”IP_ADDRESS”/html/devstat.html
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 31 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7 QUICK CHARGER OCPP INTEGRATION
7.1 INTEGRATION SETUP WEB PAGE
Integrations setup web page allows managing and enabling the integrations available
on the dropdown list.
To access to the setup web page, open a web browser and enter the following
address:
NOTE: Remember to remove the quotes when entering an address into the web browser.
The selected default option is: none.
When this option is set to none, there is no integration enabled on the charge point. In
this way, all RFID showed to the charge point can start recharging.
Available options:
- OCPP 1.2: Open Charge Point Protocol (OCPP) is an open protocol between
charging stations and managing central system.
Direct link: http://”IP ADDRESS”:65432
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 32 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2 OCPP ENGINE SETUP WEB PAGE
This website allows to setup parameters of the integration selected on the previous
section.
First time is running OCCP engine on the charge point, it starts as configuration mode
and all fields are filled by default. These parameters are always saved even when the
charge point is powered off.
To access to the OCCP engine setup web page, open a web browser and enter the
following address:
NOTE: Remember to remove the quotes when entering an address into the web browser.
NOTE: Remember to have an integration enabled before accessing this site.
Direct link: http://”IP ADDRESS”:8080
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 33 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.1 APPLICATION PARAMETERS
This section is for configuring the OCPP engine website. It is recommended leaving the
default settings.
Value Description
Administration TCP port
Port number where the OCPP engine
website is hosted.
Default parameter: 8080
Administrator Administrator username.
Default parameter: admin
New admin password Password for administrator user.
Default parameter: 1234
If a new password is entered, it will be
applied after saving new configuration.
Repeat admin password
Logging capture level
Capture mode message log of the OCPP
engine.
0 – None Not record any messages.
1 – Error Record only error messages.
2 – Info Record error and information messages.
3 – Debug
Record all messages between charge point and Central System including error and information messages.
Default parameter: 2 – Info
8080
admin
1234
1234
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 34 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.2 POWERSTUDIO ENGINE
OCPP Engine is a service running in parallel with PowerStudio and it is required to add
these parameters on this section.
Value Description
Host URL
URL where PowerStudio is hosted.
Default parameter (do not change):
http://127.0.0.1
Port PowerStudio port.
Default parameter (do not change): 80
User – System level Username and password authentication
configured on PowerStudio.
Default factory parameters:
Username: admin
Password: 1234
Password
User – Edit level Username and password configured in
the security section of setup.html website.
Default factory parameters:
Username: admin
Password: 1234
Password
http://127.0.0.1
80
admin
1234 admin
1234
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 35 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.3 CHARGE BOX (CB)
All of the parameters shown below must be assigned by OCPP central system
administrator.
Please contact to your OCPP central system administrator to get the configuration
parameters.
Value Description
Charge Box ID Charge point identifier.
Protocol
Protocol type. If HTTPS is selected,
make sure to have CS Server CA
certificate into .PEM format.
OCPP Listening port (internal) Listening port from charge point.
OCPP Listening port (public)
User (for the CB server)
Authentication parameters. New password
Repeat password
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 36 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.4 OCPP SETTINGS
Select properly values according to OCPP central system parameters. Please contact
to your administrator to select and enter the correct values.
Value Description
Use local white-list
Yes: it stores a list of authorised users of the Central
System at the charge point.
No: Authorization is consulted to the Central System
for each RFID card shown.
Use OCPP time synchronization
Yes: Local time of the charge point is synchronized
from OCPP central system time on each Heartbeat
and Boot Notification requests.
No: Local time of the charge point is not
synchronized, but remains stored in the charge
point.
Optional: Time can be synchronized through NTP server
under setup.html web page.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 37 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
Compress OCPP messages
Sending compressed messages between charge
point and central system.
NOTE: Before enabling this option, consult to your OCPP
administrator if central system allows this function.
Energy for Start/Stop
transaction
Partial: Send partial energy consumption on start /
stop messages.
Total: Send total energy values from energy meter
on start / stop messages.
Stop charge if StartTransaction
rejects the user
Identifier might have been authorized by the charge
point using an out of date white local list and may
have been blocked later from Central System.
Yes: Stop charging when the Central system rejects
the id card shown.
No: Charge point continues charging even if the
user is rejected from Central System.
Stop charge if StartTransaction
replies concurrentTX
Yes: Stop charging if same card is used to start
another charge at different charge points.
No: Same card can be used to start multiples
charging sessions in different charge points.
Heartbeat interval
Heartbeat sending interval (in seconds) for the back-
end system in order to know if charge box is still
alive.
This parameter should be overwritten by the Central
System on BootNotification response.
Connection timeout Timeout (in seconds) before connecting to the
central system.
Meter value sample interval
Meter value sample send interval (in seconds) for
the back-end system.
NOTE: Set 0 to disable meter values messages.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 38 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.5 MANAGEMENT SYSTEM (CS)
This section provides to the charge point where OCPP central system is located and if
it is requires authentication.
Please contact to your OCPP central system administrator to get the configuration
parameters.
Value Description
Host URL Address where OCPP central system is
located
User Authentication for central system.
Password
ID tag endianness Tag format stored and sent to the Central
System.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 39 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.6 SSL CERTIFICATES
Secure Sockets Layer (SSL) provides authentication and privacy of information
between charge point and central system on Internet.
Consult your OCCP central system administrator for the CS Server certificate.
Value Description
CS Server CA certificate Central System file certificate supplied by
your central system administrator.
CB Server CA certificate Upload charge box file certificate
supplied with charge point unit.
7.2.7 ACTIONS
Final options to complete the OCCP engine configuration.
Value Description
Save settings and apply.
Refresh data entered.
Import an XML file template
configuration.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 40 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.2.8 LOGS
Logs section is located at the end of the website and can be useful for checking
messages generated from PowerStudio engine, OCPP engine or operative system.
All logs shown are from charge point is started. If the unit is restarted, the messages
are deleted to display the new ones.
Value Description
System logs
Show all system logs stored:
- PowerStudio messages.
- OCPP messages.
- Operative system messages.
Application logs Show only OCPP logs stored.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 41 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
7.3 STEP BY STEP INTEGRATIONS PROCEDURE
Step Action
1
Open web browser and enter following address:
This page allows selecting and enabling the integration type on the charge
unit.
2
By default, there is no integration enabled on the charge point.
Select desired integration and click on Save setup button.
3
Enter a new address on the web browser:
This page allows setup the integration enabled in step above.
Use following default credentials:
Username admin
Password 1234
Direct link: http://”IP ADDRESS”:8080/
Direct link: http://”IP ADDRESS”:65432/
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 42 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
6
Fill the blank fields following parameters as your central system administrator.
Click on Save setup to confirm.
7
Enter following address on the web browser:
Locate Public address Manager section shown as below:
The selected default option is: Local address
Available options:
- Local address: When selected, private IP address will be sent to
OCPP central system. This option is valid if the OCPP central system is
connected to the same private network of the charge point.
- Static address: When selected, enter a value on Public IP textbox. It is
possible to enter an IP address or a domain name.
- SIERRA Wireless Raven XE H2295EW: Select this option only when
SIERRA Wireless RAVEN XE router 3G is connected on same private
network than charge point.
8
Click on Save setup to confirm.
Wait a few seconds until equipment restarts.
Direct link: http://”IP ADDRESS”/html/setup.html
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 43 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
8 URL SUMMARY TABLE
Following table shows a summary of the entire URL available as described in previous
sections.
DESCRIPTION URL
Setup http://”IP_ADDRESS”/html/setup.html
Upgrade http://”IP_ADDRESS”/html/upgrade.html
PowerStudio version http://”IP_ADDRESS”/services/system/info.html
Devices status http://”IP_ADDRESS”/html/devstat.html
Log http://”IP_ADDRESS”/html/log
Integration enable/disable http://”IP_ADDRESS”:65432
Active Integration configurator http://”IP_ADDRESS”:8080
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 44 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
9 CHARGE STATION MONITORING
The IP address assigned in last section it will be useful to connect to the charge station
to monitor the real-time status.
Two ways available to connect with charge point:
- CirCarLife client software.
You can download it from: http://circarlife.com/en/downloads/applications/applications
- Web browser.
Java software needs to be installed both cases on your computer in order to run the
client software.
Please, download last version from: www.java.com
9.1 DEFAULT FACTORY CREDENTIALS
User authentication is enabled for all quick chargers models. A window appears before
accessing to the Scada client view (charge station monitoring view).
Use following credentials:
Username admin
Password 1234
NOTE Default factory credentials can be changed using CirCarLife
Scada Editor Software (not included with charge point)
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 45 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
9.2 CIRCARLIFE CLIENT SOFTWARE
Step Action
1
Execute CirCarLife Client software.
2
Go to: General -> Connect
3
Enter IP address and port shown in the last example.
- IP address:
- Port: 80
Click OK to connect to the charge point.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 46 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
4
Prompt below appears only when authentication is enabled on the charge
point before getting access to the monitoring view.
Also is it possible to login into the system as an anonymous user.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 47 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
9.3 WEB BROWSER
It is needed to having installed the latest version of java to access to the monitoring
page. Download it from: www.java.com
Step Action
1 Execute your web browser and enter the following address:
i.e.(http://IP_ADRESS) (monitor page will open automatically)
2 Wait while the client software is starting.
3
Prompt below appears only when authentication is enabled on the charge point
before getting access to the monitoring view.
Note: If you want to log as an anonymous user, enter the word
“anonymous” in username and password fields.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 48 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
10 CIRCARLIFE SCADA CLIENT OVERVIEW
CirCarLife Scada client software allows displaying and reporting all parameters
generated by devices connected to the engine of the charge point.
Client platform is implemented in Java and can be executed on many devices.
Devices connected to the charge point may vary depending on model purchased.
CirCarLife Scada client is divided on 4 sections:
1. Menu bar
2. Toolbar
3. Screen information
4. Status bar
Following section describes in detail each of the points mentioned above.
2
4
1
3
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 49 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
10.1 MENU BAR
Menu bar is located at the top and provides access to all available client features.
There are three main menus, "Options", "Views" and "General".
10.1.1 OPTIONS MENU
Option Description
Properties
Displays properties of the currently active view. This option can
be active or not depending on the view in progress.
Print currently active view. This option can be active or not
depending on the view in progress.
Export
Exports currently active view. This option can be active or not
depending on the view in progress.
Exit Close the client software.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 50 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
10.1.2 VIEWS MENU
Option Description
Previous Displays the previous view.
Next Displays the next view (If available).
Historic Displays any view previously consulted.
Study Displays graph and tables views.
Screens Displays one of the user-defined Scada screens.
Reports Displays one of the user-defined reports.
Devices Device list shortcut.
Events Displays the events log or the active events window.
Device status Display the general status of all connected devices.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 51 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
10.1.3 GENERAL MENU
Option Description
Toolbar Displays or hides the toolbar.
Statusbar Displays or hides the status bar.
Alarm if it not
communicate
Audible alarm if communication is lost between charge
point and computer connected.
Events actions List of actions enabled in the client software.
Connect Connects with another CirCarLife Engine.
Logout
Closes the current session. Only available when the user
has connected to engine that requires authentication.
Language Changes the client application language.
Look and feel Changes the appearance of the client application (Skin).
Graphs properties Changes graph appearance.
About Displays client application information.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 52 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
10.2 TOOLBAR
Toolbar contains the most frequent options used in the client software.
Option Description
Previous Displays the previous view.
Next Displays the next view. If available.
“Down arrow” Displays any view previously consulted.
Devices Device list shortcut.
Screens Displays one of the user-defined SCADA screens.
Reports Displays one of the user-defined reports.
Graph Creates a graph.
Table Creates a table.
Events Displays event history
Properties Displays the properties window of the current view.
Print Allows us to print the current view.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 53 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
10.2.1 TOOLBAR SETUP MENU
It is possible to hide or display buttons for the toolbar. Right-click on the toolbar and
following setup menu appears:
NOTE: The toolbar may be hidden using the “General” menu. The menu bar may be hidden
using the “Enable menu and toolbar” option in the editor “Preferences”. Using this latter method
it will not be possible to make it appear again from the client application.
10.3 STATUS BAR
Status bar is located at the bottom of the client software and it contains general
information about status of CirCarLife Scada engine connected.
OVERVIEW
Status Description
Online CirCarLife Scada engine
and working properly.
Offline CirCarLife Scada engine.
Engine status
Engine name, IP and port
Incidences
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 54 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
Incidences Description
One or more devices are not
communicating.
See device status section to find witch
device is not communicating.
One or more devices are not reporting.
One or more events are active.
Double-click over icon showed to see details.
NOTE: Status bar can be hidden using the "General” option in the client application menu. It
may also be hidden using the “Enable menu and toolbar” option in editor “Preferences”. In the
latter case it will not be possible to make it appear again from the client application.
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 55 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
11 APPENDIX A: SCADA SOFTWARE FEATURES
11.1 SCADA DEVICES STATUS
Scada devices status section allows to view the overall status of all devices connected
to the engine in real-time status.
NOTE: In the right pane shows details when one device is selected.
ICON STATUS COMMENTS
OK Equipment communicating properly.
Downloading data Querying device data information
Connection error Port invalid or is not configured properly.
Device not initialized. Failed to establish initial communication with the
device.
Communications fault Unable to re-establish communication with the
equipment; response time exceeded.
Incorrect version Equipment is communicating properly, but the
version of the engine does not support it.
Channel error Unable to open communications port.
Communications fault Some devices cannot communicate properly.
“Device status” section is located under "Views" option from the menu bar.
EXAMPLE
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941 56 Web: www.circontrol.com – E-mail: [email protected]
TRI RAPID CHARGER – INSTRUCTION MANUAL –
11.1.1 VIEW SELECTION
Devices can also be displayed by different views through the “Properties” button on the
toolbar.
11.1.2 DISPLAYING REALTIME DEVICES
CirCarLife Scada client software allows easily navigate between devices connected to
the engine to display the values contained in each device in real-time.
NOTE: the device list may vary depending on the charge point.
“Devices” option is located under "Views" option from the menu bar.
Also accessible from toolbar.
EXAMPLES
1
2
1
2