82

Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

Embed Size (px)

DESCRIPTION

EV charging stations product catalogue

Citation preview

Page 1: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations
Page 2: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations
Page 3: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CirCarLife - Catalogue 2013-2014

INDEX

E INTELLIGENT RECHARGING SOLUTIONS FOR ELECTRIC VEHICLES

E1 INTRODUCTION5

E1.1 CHARGING MODES 5

E1.2 CONNECTOR TYPES 6

E2 WALLBOX SMART CHARGING SYSTEM FOR CAR PARKS AND COMMUNAL BLOCKS

7

E2.1 BASIC SERIES 8

E2.2 SMART SERIES 10

E3 POST CHARGING SYSTEM FOR CITY STREETS AND INTER-CITY ROADS

12

E3.1 BASIC CHARGING POSTS 13

E3.2 POST URBAN SMART SERIES 15

E3.3 SMART CHARGING POSTS SERIES 17

E3.4 TWO WHEELS VEHICLE CHARGING SYSTEM 19

E4 MULTIPOINT SYSTEM 21

E4.1 MASTER CONTROLLER 22

E4.2 SLAVE WALLBOX 24

E5 QUICK CHARGING SYSTEM 26

E5.1 QUICK CHARGING ADVANCE SYSTEM 27

E5.2 QUICK CHARGING COMPACT SYSTEM 29

E5.3 QUICK CHARGING COMBO 2 CCS SYSTEM 31

E6 MANAGEMENT AND CONTROL SOFTWARE 33

E7 ACCESSORIES 34

E7.1 SMART STANDALONE DATA CENTRALISING UNIT 34

E7.2 COMMUNICATION ACCESSORIES 35

E7.3 PRE-PAYMENT SOLUTIONS 36

E8 TECHNICAL FEATURES 37

Page 4: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

ULTRA-FAST CHARGING

SYSTEM

ELECTRIC VEHICLE CHARGING

IN CITY STREETS

ELECTRIC VEHICLE

CHARGING IN PUBLIC CAR

PARKS (INDOORS)

ELECTRIC VEHICLE

CHARGING IN COMMUNAL

BLOCKS

ELECTRIC VEHICLE

CHARGING IN CAR PARKS(OUTDOORS)

4

1

Page 5: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

5

.Catalogue 2013-2014

E1 INTRODUCTION

E1.1 CHARGING MODESThe EV charging process is regulated by the IEC 61851 and IEC 62196 international standards. These standards de�ne the different charging modes and the type of connection required to charge EVs. All CirCarlife products have been created and designed in compliance with the strictest European regulations and standards, prioritising the end user’s safety. CIRCONTROL is a leading and constantly innovating company committed to developing its products and adapting them to market requirements.

charging modes and the type of connection required to charge EVs. All CirCarlife products have been created and designed in compliance with the strictest European regulations and standards, prioritising the end user’s safety. CIRCONTROL is a leading and constantly innovating company committed to developing its products and adapting them to market requirements.

Standard electrical network connector, non-speci�c for EVs.

Slow AC charging.

The installation must be protected with circuit breakers and earth leaka-ge protection elements.

Maximum 16 A per phase (3.7 kW - 11kW).

Technical features

Mode 1

Standard electrical network connector, non-speci�c for EVs.

Slow AC charging.

The installation must be protected with circuit breakers and earth leaka-ge protection elements.

Maximum 32 A per phase (3.4 kW - 22kW).

Special cable with an intermediate electronic device, with a control and protection pilot function.

Technical features

Mode 2

Electrical network connector, speci�c for EVs.

Slow or semi-fast charging in single or three-phase installations.

Protection elements included in the special infrastructure for EVs.

Maximum 64 A per phase (14.8 kW - 43 kW).

Direct connection of the EV to the charging unit.

Technical features

Mode 3

Electrical network connector, speci�c for EVs.

Quick DC charging.

Charging station, exclusively used for EVs.

Maximum 400 A per phase (50 kW - 150 kW).

Control and protection elements installed in the infrastructure.

Technical features

Mode 4

CirCarLifeIntelligent recharging solutions for electric vehicles

1

Page 6: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

6

.Catalogue 2013-2014.Catalogue 2013-2014

E1.2 TYPES OF CONNECTORS

SAE J1772 Regulation.

5 pins (L1/N, PE, CP, CS).

Maximum 230Vac 32A single-phase (7.3kW).

Indirect connection between the EV and DC supply point. Control and protection elements installed in the infrastructure.

7 pins (L1, L2, L3, N, PE, CP, PP).

Maximum 400Vac 32A three-phase (21kW).

7 pins (L1, L2, L3, N, PE, CP, PP).

Maximum 400Vac 63A three-phase (43kW).

Type 1

Type 2

Type 3

ChaDeMo

DC connector of the combined AC/DC plug-in charging system:The inlet of the plug-in connector can also be used for AC voltage charging with a type 2 AC plug. One inlet is required on the vehicle side for AC and DC charging.

Combined Charging System

1

Page 7: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

7

2

Different types of car parks have different electric vehicle charging features and requirements. That is why different electric vehicle charging equipment solutions are required for each type of installation.

Circontrol offers a variety of different solutions, adapted to each type of car park, whether in single-family homes, communal residence car parks, public and shopping mall car parks, hotels, etc. These solutions consist of devices that can function standalone and devices with com-munication ability which enable speci�c functions via software adapted to each type of installation.

E2. WALLBOX CHARGING SYSTEM FOR CAR PARKSAND COMMUNAL BLOCKS

BASIC Series SMART Series

Description

Charge Status Light Indicator

RFID Communication Metering

BASIC - - -

SMART

Product Range - WallBox charging

CirCarLifeIntelligent recharging solutions for electric vehicles

Page 8: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

8

.Catalogue 2013-2014

2

E2.1 BASIC SERIESWallBox charging system for domestic use

The Wall Box Basic has been specially designed for do-mestic use on indoor or outdoor residential garages. Compatible with all hybrid plug in or pure electric cars with an easy installation ondo your garage wall. Capable to charge complying with safety regulations your electric car during overnight meanwhile your fa-mily sleep and be ready for your next day journey.

With the auto start mode 3 system and with the three light colour indicators located in the wall box you can easily charge and monitor your electrical vehicle charge.

Description

Self-extinguishing ABS plastic casing. Protection degree : IP54.

Compatible with Mode 3 IEC 61851-1. (Certi�ed).

Type I, Type II, Type III or Schuko connectors, in compliance with the IEC

Type I support, cable and connector.

Simple installation, 4-point wall �xing.

Self-extinguishing ABS plastic casing.

Charge status light indicator (blue, green and red).

Customized paint housing and logos.

Technical features

Page 9: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

9

2

TypeNum.

Sockets

Input Supply Voltage

Output Power Output Current Charge systemTechnical Features

PageSocket A Socket B Socket A Socket B Socket ASocket

B

CCL-WBC

1 230 Vac 3,6 kW - 16 A -Mode 3 & Type 1

- 38

CCL-WBC 32

1 230 Vac 7,2 kW - 32 A -Mode 3 & Type 1

- 39

CCL-WB MIX

2230

Vac/400Vac*3,6kW

7,2 kW / 21 kW

16 A 32 AMode 3 & Type 2

Mode 1Schuko

40

CCL-WBM

1230

Vac/400Vac*7,2 kW/21kW* - 32 A -

Mode 3 & Type 2

- 41

CCL-WBMC

1230

Vac/400Vac*7,2 kW/21kW* - 32 A -

Mode 3 & Type 2

- 42

Unit dimensions and cable support

320mm

51mm

225mm 109mm

125mmWALLBOX CHARGING

CONNECTION CABLE SUPPORTINCLUDED ONLY WBC SERIES

* Depends of local instalation WB accepts both

Technical Features

Page 10: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

10

.Catalogue 2013-2014

2

E2.2 SMART SERIESWallBox charging system for car parks and communal blocks

Description

The Wall Box smart was specially designed for public indoor-outdoor car park installations as well as multi-family homes, shopping malls, municipalities, private companies, etc.

These series provide multiple power options and meet all ve-hicles standards to charge whole hybrid plug in and pure electrical vehicles existing in the market. The station incor-porates display, RFID (card reader), smart metering and com-munication capabilities to be adapted in an innovative smart grid systems.

Protection degree : IP54.

Compatible with Mode 3 IEC 61851-1. (Certi�ed).

Type I, Type II, Type III or Schuko connectors, in compliance with the IEC

Charge status light indicator (blue, green and red).

Simple installation, 4-point wall �xing.

Self-extinguishing ABS plastic casing.

Type I support, cable and connector. Type 2 connector lock.

Customised color housing and logos.

Technical feature

Backlight LCD display.

Integrated energy measurement (Class 1 meter).

Pre-payment and access control with RFID cards.

Ethernet communications and data storage.

3G and GPRS communications (optional).

SCADA control software connection.

Integration with other software (OCPP, XML, ...).

Unit dimensions and cable support

320 mm

51 mm

225 mm 109 mm

125 mmWALLBOX CHARGING

CONNECTION CABLE SUPPORTINCLUDED ONLY WBC SERIES

Page 11: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

11

2

CCL-WBC SMART

Num. Sockets

Input Supply Voltage

Output Power Output Current Charge systemTechnical Features

PageSocket A Socket B Socket A Socket B Socket A Socket B

CCL-WBC SMART

1 230 Vac 3,6 kW _ 16 A _Mode 3Type 1

_ 43

CCL-WBC 32 SMART

1 230 Vac 7,2 kW _ 32 A _Mode 3Type 1

_ 44

CCL-WBM SMART

1 230 Vac 7,2 kW _ 32 A _Mode 3Type 2

_ 45

CCL-WBS SMART

1 230 Vac 3,6 kW _ 16 A _Mode 1Shucko

_ 46

CCL-WB MIX SMART

2 230 Vac 7,2 kW 3,6 kW 32 A 16 AMode 3Type 2

Mode 1Shucko

47

CCL-WB2M SMART

2 230 Vac 7,2 kW 7,2 kW 32 A 32 AMode 3Type 2

Mode 3Type 2

48

CCL-WBM SMART TRI

1 400 Vac 22 kW _ 32 A _Mode 3Type 2

_ 49

CCL-WB MIX SMART TRI

2 400 Vac 22 kW 3,6 kW 32 A 16 AMode 3Type 2

Mode 1Shucko

50

CCL-WB2M SMART TRI

2 400 Vac 22 kW 22 kW 32 A 32 AMode 3Type 2

Mode 3Type 2

51

Technical Features

Page 12: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CirCarLife

12

.Catalogue 2013-2014

3

CirCarLifeIntelligent recharging solutions for electric vehicles

Charging systems for city streets require very speci�c features, especially in terms of robustness, through being exposed to variable environmental conditions, including acts of vandalism. Besides the- se special re-quirements, they should also have the adequate electric safety measures for equipment with characteristics such as these.

With this in mind, circontrol provides innovative smart charging so- lutions that are adapted to the special conditions of city streets for all sorts of two and four-wheel vehicles, according to the latest in- ternational charging regulations and offering a variety of solutions for each type of installation.

E3. CHARGING SYSTEMS FOR CITY STREETS AND INTER-CITY ROADS

BASIC Series 2-WHEELVEHICLES Series

Description

Product Range - POST charging

SMART Series

RFIDDisplay for credit

monitoringCommunication Mode 3 Socket

BASIC SERIES

-

SMART URBAN SERIES

SMART SERIES

2-WHEEL VEHICLES

SERIES-

SMART URBAN Series

Page 13: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

13

3

Description

The vehicle recharge posts of the CirCarLife family of products, has been designed to �t all needs in electrical vehicles recharge on the street, compliant with all electrical security regulations as well as access security and me-tering and consumption management.

The robustness for its use and against vandalism is one of the aspects taken in account when designing and developing this equipment, as well as �t them with a temperate and smart aesthetic design. All family CirCarLife range of pro-ducts has been thought to give the electrical vehicle user, a simple method for recharge his vehicle everywhere he parks it, that way the recharging posts has been equipped with a simple access system and energy payment through contact-less cards, as well as a handy and easy opening and closing system, that way all the recharge process could be ful�lled with only a few steps by any user without technical knowled-ge needs.

Aplications

All outdoor places or these that could be used for any kind of vehicle parking (cars, motorcycles, bikes, transport, cleaning, …). An example of this could be public street, public outdoor car parks, outdoor car parks on big malls, airports, car rental companies, cleaning companies, etc. Features

• Access and prepayment with proximity cards (RFID)

• Safety user protection for voltage danger (EU regulation)

• Intelligent and anti-vandalism opening system

• Integrated energy measurement (kWh)

• Protection system against energy fraud

• Integrated electrical protections with self reclosing system

• Display for credit monitoring

• Ready for outdoor use (IP54)

• Coated with anti-graffiti paint

• Anti-vandalism stainless steel body

• Smart aesthetic design

• Communications (optional)

Backlight display, indicating the available credit

Circular stainless steel housing

Protection degree : IP54 and anti-graf�ti paint

Type of Connector: Schuko

RFID Identi�cation and pre-payment

Self-resetting circuit breaker and earth leakage protection

Remote control and monitoring of the unit

Built-in energy metering system

Connected to SCADA control software

Remote control and monitoring of the unit

Built-in energy metering system

Current socket lock with mobile head

Technical features

E3.1 POST BASIC SERIESCharging systems for city streets and intercity roads

Page 14: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

14

.Catalogue 2013-2014

3

Technical features

TypeNum.

Sockets

Input Supply Voltage

Output Power Output Current Charge systemNetworkConnection

Technical Features

PageSocket ASocket

BSocket A Socket B Socket A Socket B

CCL-PE1 COM

1 230 Vac 3,6 kW _ 16 A _Mode 1Shucko

_ RS-485 52

CCL-PE2 COM

2 230 Vac 3,6 kW 3,6 kW 16 A 16 AMode 1Shucko

Mode 1Shucko

RS-485 53

CCL-PE2 IP

2 230 Vac 3,6 kW 3,6 kW 16 A 16 AMode 1Shucko

Mode 1Shucko

RS-485Ethernet

54

CCL-PE2 MOV

2 230 Vac 3,6 kW 3,6 kW 16 A 16 AMode 1Shucko

Mode 1Shucko

RS-485Ethernet

3G55

Unit dimensions

Page 15: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

15

3

The new Urban Post series, are being launched by Circontrol to be installed on streets and intercity streets for two and four-wheel electrical vehicles. Due to this, Urban Post meets the máximum protection level against vandalism at EU (IK10) and its enclosure allow to work at extrem temperatures and raining places. Improving the life lenght of the electrical charger.

As this is a product designed to be used by different users at many countries around the world, it is compatible with XML & OCPP protocol and also with the most relevant existing back of�ces.

This product has already tested and certi�ed with the most relevant European and Japanese car manufacturers, with great results in terms of efficiency and reliability. Following the philosophy of Circontrol, Urban Post can be customize by software and brand labelling for relevant orders or new distributors.

Instructions on the screen in several languages

Network connection Ethernet and 3G (optional)

Status light indicator

User ID by RFID card, and mobile payment (App, etc.)

Possibility to use front panel for publicity

Dimensions: 940 mm x 450 mm x 195 mm

E.3.2 POST URBAN SERIESCharging systems for city streets and intercity roads

Description

General features

Technical features

Two sockets available at same time (one socket by side)

Power range by socket at 230 V 3,6 kW up to 7,2 kW

Power range by socket at 400 V 11 kW up to 22 kW

Enclosure rating: IP 54 / IK 10 (stainless steel housing)

Compatible with Mode 3 IEC 61851-1 (Certi�ed)

Operating temperature: -30°C to + 45°C

Unit dimensions

450 mm

944,

95 m

m

166,94 mm

Page 16: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

16

.Catalogue 2013-2014

3

TypeNum.

Sockets

Input Supply Voltage

Output Power Output Current Charge systemNetworkConnection

Technical Features

PageSocket A Socket B Socket A Socket B Socket A Socket B

CCL-PM3-Urban

2 230 Vac 3,6 kW 3,6 kW 16 A 16 AMode 3 Type 2

Mode 3 Type 2

Ethernet & 3G

(Optional)56

CCL-PM-MIX-Urban

2 230 Vac 3,6 kW 3,6 kW 16 A 16 AMode 3 Type 2

Mode 1Shucko

Ethernet & 3G

(Optional)57

CCL-PM-MIX4-Urban

4 230 Vac

7,2kW (Socket A)

3.6kW (Socket A1)

7,2kW (Socket B)

3.6kW (Socket B1)

32A (Socket A)

16A (Socket A1)

32A (Socket B)

16A (Socket B1)

Mode 3 Type 2

(Socket A)

Mode 1 & Mode Shucko

(Socket A1)

Mode 3 Type 2

(Socket B)

Mode 1 & Mode Shucko

(Socket B1)

Ethernet & 3G (Optional) 58

CCL-PT3-Urban

2 400 Vac 22 kW 22 kW 32 A 32 AMode 3 Type 2

Mode 3 Type 2

Ethernet & 3G

(Optional)59

CCL-PT-MIX-Urban

2 400 Vac 22 kW 3,6 kW 32 A 16 AMode 3 Type 2

Mode 1 & Mode Shucko

Ethernet & 3G

(Optional)60

CCL-PT-MIX4-Urban

4 400 Vac

22kW (Socket A)

3.6kW (Socket A1)

22kW (Socket B)

3.6kW (Socket B1)

32A (Socket A)

16A (Socket A1)

32A (Socket B)

16A (Socket B1)

Mode 3 Type 2

(Socket A)

Mode 1 & Mode Shucko

(Socket A1)

Mode 3 Type 2

(Socket B)

Mode 1 & Mode Shucko

(Socket B1)

Ethernet & 3G (Optional)

61

Technical features

Page 17: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

17

3

Description

Smart post series provides a durable and modular enclosure with the robustness ne-cessary to support hard climatic conditions along the streets. Equipped with latest tech-nology in terms of communication and safe-ty devices allows charge electrical vehicle in a easy and protected way.

With an easy and friendly use driver will experience the best way to charge a electrical vehicleIncludes advanced communication capabilities to monitor and setup remotely as well as RFID reader.

E3.3 POST SMART SERIESCharging systems for city streets and intercity roads

Backlight LCD display

Kwh consumption in real time

Indicators: “Available”, “Reserved”, “Not available”

Instructions for use displayed on the screen

User ID

Compatible with Mode 3 IEC 61851-1 (Certi�ed)

Type I, Type II or Schuko connectors, in compliance with the IEC 62196-2 regulations

Technical features

Unit Dimensions

the IEC 62196-2 regulations

380 mm

1590

mm

280 mm

Page 18: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

18

.Catalogue 2013-2014

3

TypeNum.

Sockets

Input Supply Voltage

Output Power Output Current Charge systemNetworkConnection

Technical Features

PageSocket A Socket B Socket A Socket B Socket A Socket B

CCL-PM1

2 230 Vac 3,6 kW 3,6 kW 16 A 16 AMode 1Shucko

Mode 1Shucko

Ethernet & 3G (Optional)

62

CCL-PM3

2 230 Vac 7,3 kW 7,3 kW 32 A 32 AMode 3Type 2

Mode 3Type 2

Ethernet & 3G (Optional)

63

CCL-PM-MIX

2 230 Vac 7,3 kW 3,6 kW 32 A 16 AMode 3Type 2

Mode 1Shucko

Ethernet & 3G (Optional)

64

CCL-PT3

2 400 Vac 22 kW 21 kW 32 A 32 AMode 3Type 2

Mode 3Type 2

Ethernet & 3G (Optional)

65

CCL-PT-MIX

2 400 Vac 22 kW 3,6 kW 32 A 16 AMode 3Type 2

Mode 1Shucko

Ethernet & 3G (Optional)

66

CCL-PT3 63

1 400 Vac 43 kW _ 63 A _Mode 3Type 2

_Ethernet & 3G

(Optional)67

Technical features

Page 19: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

19

3

Description

The 2 wheel vehicle recharging solution of the CirCarLife family has been designed to cover up the needs of 2 wheel electrical vehi-cles like motorcycles or electrical bikes, com-pliant with all electrical security regulations as well as access security and metering and consumption management.

This solution consists of a controller that manages prepayment through RFID proximity cards and allows the outlet selection and manages the consumption en each outlet. Furthermore this solution integrates security systems to �t users and elec-trical vehicles. Joint to the controller there is a bracket with all electricity out-lets for different kinds of 2 wheel vehicles, each outlet is sepa-rate from the others in a speci�c distance that allows parking the vehicle for recharging purposes in a comfortable way. The robustness for its use and against vandalism as well as installation and use facilities is one of the aspects taken in ac-count when designing and developing this equipment. Fur-thermore this equipment emphasizes for its compact design with high technological level integrated.

All family CirCarLife range of products has been thought to give the electrical vehicle user, a simple method for recharge his vehicle everywhere he parks it, that way, the recharging boxes has been equipped with a simple access system and energy payment through contactless cards, that way all the recharge process could be ful�lled with only a few steps by any user without technical knowledge needs.

The recharge stations for two wheel vehicles has been desig-ned to be installed on public street or in dedicated parks for motorbikes or bikes, its special design makes it ideal to �t any installation place where any 2 wheel vehicle can park.

Aplications

• Access and prepayment with proximity cards (RFID)

• Safety user protection for voltage danger (EU regulation)

• Intelligent and anti-vandalism opening system

• Integrated energy measurement (Kwh)

• Protection system against energy fraud

• Integrated electrical protections with self reclosing system

• Display for credit monitoring

• Ready for outdoor use (IP54)

• Coated with anti-graffiti paint

• Anti-vandalism stainless steel body

• Smart aesthetic design

• Communications (optional)

• Push buttons for selection

Features

E3.4 2-WHEEL SERIESCharging systems for city streets and intercity roads

Vandal-proof metallic casing

Protection degree : IP54

Energy meter

RFID Identi�cation and pre-payment

Backlight display with an indicator of the available credit

Selection push-buttons, with status indicator

Circuit breaker and earth leakage protection

Communications: Ethernet and RS-485, 3G (optional)

Charging data storage

Technical features

Page 20: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

20

.Catalogue 2013-2014

3

TypeNum.

Sockets

Input Supply Voltage

Maximum consumitionper outlet

Maximum output current

Charge systemTechnical Features

Page

CCL-CB3 IP

3 230 Vac 9,2 kW 16AMode 1 Shucko

68

CCL-CB6 IP

6 230 Vac 9,2 kW 16AMode 1 Shucko

68

Technical features

Page 21: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

21

.Catalogue 2013-2014

CIRCONTROL - CirCarLife

4

CirCarLifeIntelligent recharging solutions for electric vehicles

The multi-point system of the CirCarLife range has been designed to offer a smart electric vehicle charging solution for car parks with multiple outlet sockets for electrical vehicles.

This solution allows smart electric vehicle charging management of a large number of electric vehicles, con-trolling different parameters of the electric network and the vehicles connected to it, as well as user and car park manager preferences. In this way, users can get maximum results from vehicle charging in accordance with user requirements by charging under the most favourable conditions in terms of electricity tariffs or by opting for immediate charging.

E4. MULTIPOINT SYSTEM

Description

Sockets Series

1 2 3 4

COMMUNICATIONS

RS, Ethernet, Zigbee, PLC, GSM, GPRS

SAVING AND FILTERING

Harmonics FilteringReactive Compensation

IDENTIFICATION

RFIDBar CodeMagnetic Stripe

INTEGRATION WITH OTHER SYSTEMS

Payment SystemsOcupation and guidanceLightingPay and display

ENERGY MANAGEMENT

MeasurementQualityConsumptionAdapt to electrical tariffControl of Recharges

PC SOFTWARE

Real TimeMultiuserGraphicsRemote ConnectionWebXNL interfaceAlarm’s ManagementHistorical GenerationMultiplatform

ELECTRIC COMPANYSIGNAL

Ethernet

3rd system interface

Com

mun

icat

ion

Seria

l RS-

485

(...)

CONTROLLER Series

Page 22: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

22

.Catalogue 2013-2014

4

Description

MULTIPOINT SYSTEM has been designed as an extremely flexible system. Its special configuration can cater for speci�c vehicle charging needs of the current market. In addition, it is a scalable system that can control up to 32 charging stations in its most basic con�guration.

The system is composed of the following basic units:• CCL-CM: CPU (industrial PC with PowerStudio software), 10” Touch Screen• CCL-SL Charging Station

E4.1 Master controller

CCL-SL Charging Station offers

• User interface 10” Touch screen as standard. This is the natural complement of the PowerStudio software, which allows interaction with the user. PowerStudio software, is capable of ef�ciently managing the power available, con-trolling the main’s harmonics (upper measurement system is needed), charging vehicles in off-peak periods, etc.

• The user can browse through the screens that have been designed with ergonomics in mind to select the parking pla-ce, check their charging status, , energy consumed., etc. • Massive storage for all statistical studies.

• All of the current communications power used nowadays (ICT).

• Modbus Communications Protocol to communicate with the charging bases or other speci�c Energy Ef�ciency devi-ces.

• XML Communications Protocol, which enables the inte-gration with other automated parking and car park systems (blue parking areas, car parks in general, access control po-ints, etc.). In addition, it offers remote station management options to parking operators like statistics, remote activation/deactivation, etc.

• Card reader. Built-in prepayment card reader Mifare type as standard, but it can be replaced or complemented with any other reader available in the market.

• The CCL-SL Charging Station it’s a wall-mount charging box that guarantees a safe collection of the energy for the energy of the installation operator, prevents fraud and misu-se of the energy.

• Also provide reliable measurement system for the user, sin-ce only the energy consumed is paid, with an accurate rea-ding of the energy consumed.

• Protects end users against electrical risks. Current is only present during the charging cycle.

• Current antitheft prevention function. The operation is in-terrupted if the socket is removed during the charging pro-cess, so that no more energy will be supplied to the base until the user is identi�ed again.

• In the event of an overload, the maximum current detec-tion and limiting system is activated before the protection circuit breaker is tripped, in order to prevent subsequent maintenance operations.

- Pre-payment cards. Available without credits (paid at a later stage) and pre-charged with 5, 20, 50 or 99 credits.- Pre-payment cards recharging tools.

There are three models available for the recharging of the CirCarLife cards:o CCL-Cash: Cashier for the recharging of prepayment cards, able of accepting credit cards and notes.o CCL-Term: standalone terminal for recharging cards.o CCL-Soft: Software and USB peripheral reader for recharging cards.

CCL-CM offers the following functions

The complementary units that offer all other features to the system are as follows:

Page 23: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

23

4

More options and accessories

• Upper measurement systems used to control the power available to the installation. The energy available can be limited, bypassed or distributed to the different vehicles connected to the main. To be de�ned, in accordance with the particular con-ditions of each installation.

• Upper measurement and control systems used to control the quality of energy. Measurement and control of harmonics. To be de�ned, in accordance with the particular conditions of each installation.

• Any unit of the CIRCARLIFE family (outdoor posts, wall-mount units, two wheels...) can be connected to the MULTIPOINT system (Standard screen must be adapted).

• The MULTIPOINT SYSTEM vehicle charge unit complies with the CE requirements and the current European Union directives for this type of equipment.

Unit dimensions

These units do not require special anchoring instructions since they are standard in any electrical box installation.The anchoring structure is prepared for 8 mm lag screws or threaded plugs on the CM box and 6 mm on the SL box.

Type Input Voltage LAN Network SL Charging PointScalable master WB control

Technical Features

Page

CCL-CM

230V AC 1P+N Ethernet RJ45 RS 485 Modbus 32 WB Points 69

Technical Features

mm

mm

mm

mm

mm

mmm

mmm

mm

mm

Page 24: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

24

.Catalogue 2013-2014

4

Description

The multi-point system of the CirCarLife range has been designed to offer a smart electric vehicle charging solution for car parks with multiple outlet sockets for elec-trical vehicles.

This solution allows smart electric vehicle charging manage-ment of a large number of electric vehicles, controlling di-fferent parameters of the electric network and the vehicles connected to it, as well as user and car park manager pre-ferences. In this way, users can get maximum results from vehicle charging in accordance with user requirements by charging under the most favourable conditions in terms of electricity tariffs or by opting for immediate charging.

E4.2 Slave Wallbox

Protection degree : IP54

Built-in energy metering system

Compatible with Mode 3 IEC 61851-1. (Certi�ed)

Charge status light indicator (blue, green and red)

Type II or Schuko connectors, in compliance with the IEC 62196-2 regulations

Simple installation. 4-point wall �xing

Self-extinguishing ABS plastic casing

Communications: RS-485

Customised housing �nish and logos

Elegant, aesthetic design

Technical features of WallBox boxes

Unit dimensions

320 mm

51 mm

225 mm 109 mm

125 mm

WALLBOX CHARGING CONNECTION CABLE SUPPORTINCLUDED ONLY WBC SERIES

Page 25: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

25

4

Techincal Features

Basic Series

CCL-WBC SMARTNum.

Sockets

Input Supply Voltage

Output Power Output Current Charge systemTechnical Features

PageSocket A Socket B Socket A Socket B Socket A Socket B

CCL-WB-SL

1 230 Vac 3,6 kW _ 16A _Mode 1Shucko

_ 70

CCL-WBM SL

1 230 Vac 7,2 kW _ 32 A _Mode 3Type 2

_ 70

CCL-WBC 16 SL

1 230 Vac 3,6 kW _ 16A _Mode 3Type 1

_ 70

CCL-WBC 32 SL

1 230 Vac 7,2 kW _ 32 A _Mode 3Type 1

_ 70

CCL-WB-SL-MIX

2 230 Vac 3,6 kW 7,2 kW 16 A 32AMode 1Shucko

Mode 3Type 2

70

CCL-WBM-SL TRI

1 400 Vac 22 kW _ 32 A _Mode 3Type 2

_ 71

CCL-WB-SL MIX TRI

2 230 Vac 3,6 kW 22 kW 16 A 32 AMode 3Type 2

Mode 1Shucko

71

Page 26: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

26

.Catalogue 2013

5

CirCarLifeIntelligent recharging solutions for electric vehicles

E5. QUICK CHARGING SYSTEM

CIRCONTROL’s ultra-fast charging stations offer the fastest way to recharge the current electric vehicles used. the innovative construc- tion design offers a quick charging solution that is easy to use and complies with the current standards (CHAdeMO, Combo...) for fast electric vehi- cle charging with direct current. ease of installation and electrical pro- tection to increase user safety are other major factors of consideration in the system design.

Integrated communications in this device enable permanent connec- tion with a remote control station, which monitors the device charging data in real time and activates the device remotely, meaning it can be simply and fully exploited.

Integrated dispen-ser power unit Communication CHAdeMO Socket Combo Socket

ADVANCE - -

COMPACT -

COMBO 2 (CCS)

ADVANCE COMPACT COMBO 2

Description

Page 27: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

27

5Type Ref V in I in P in F Hz V out I out

Connector type

Charging Mode

TechnicalFeatures

Page

QP1CCL- QP1

400VAC 80A 58 kVA 50/60Hz +/- 5%

500VDC 120ADC JEVS G105 Mode 4 72CCL- QPM

QPMIX

CCL- QP-MIX

400VAC 117A 84 kVA 50/60Hz +/- 5%

500VDC (Connector 1)

120ADC (Connector 1)

JEVS G105(Connector 1)

Mode 4(Connector 1)

73Mode 3

(Connector 2)CCL- QPM MIX

400VAC(Connector 2)

32A(Connector 2)

Type2(Connector 2)

QPMIX 63

CCL- QP-MIX 63

400VAC 143A 103 kVA 50/60Hz +/- 5%

500VDC (Connector 1)

120ADC(Connector 1)

JEVS G105(Connector 1)

Mode 4(Connector 1)

74

CCL- QPM MIX 63

400VAC(Connector 2)

63A(Connector 2)

Type2(Connector 2)

Mode 3(Connector 2)

QP2

CCL- QP2

400VAC 160A 170 kVA 50/60Hz +/- 5%

500VDC(Connector 1)

120ADC (Connector 1)

JEVS G105 x2(Connector 1)

Mode 4 75CCL- QPM

500VDC(Connector 2)

120ADC(Connector 2)

JEVS G105 x2(Connector 2)CCL- QPM

Accesories

Accesories

Ref Code Description

CCL-QP-FIL 490065 Harmonics Filter

CCL-QP-IP55 490103 IP55 Conversion for CCL-QPM

CCL-QP-3G 460066 3G Modem

AC/DC Fast charger

Technical especi�cations

Description

Circontrol’s quick charging stations are the fastests way of charging today’s electric vehicles. Their innovative, original design offers a fast, easy to use charging solution, in line with CHAdeMO’s current standards for the quick, direct current charging of electric vehicles.

This solution has a user friendly interface, vandal proof de-sign and easy to install structure. Communications (Ethernet, 3G...) has been integrated in all models allowing remote con-trolling of the units and remote monitoring in real time. This feature provides and easy way to integrate in higher systems allowing owner to take pro�t of it.

E5.1 QUICK CHARGING ADVANCE SYSTEM

AC

QPMIX

CCL- QPM MIX

QPMIX 63

Page 28: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

28

.Catalogue 2013-2014

5

LCD Screen for user interaction.

Start, Stop and Emergency Stop buttons.

Light indicator of the charging status.

Instructions for use displayed on the screen.

RFID Identi�cation and pre-payment.

User interface

Power module and charging station splitted.

IK10 Vandal-proof polyurethane casing.

Standard working temperature range: -10ºC to 45ºC.

Overcurrent and earth leakage protection.

EV Standar: IEC 62196-3, IEC 61851-1, CHAdeMO.

Harmonic Filtering.

IP55 Protection for power module.

3G Communications.

Options

Security & Protection

Current socket lock during the charging process (Mode 3 & Mode 4).

Consumption counter kWh and charging time displayed.

Time and consumption based prepayment modes.

Simultaneous charging AC & DC.

Communications & Protocols.

Remote control and monitoring of the unit through standar XML & HTML.

OCPP Protocol integration.

Ethernet: 10/100BaseTX communication.

Embedded Scada Software for mantenance & control.

Charging Management

Technical features

Page 29: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

29

5

E5.2 QUICK CHARGING COMPACT SYSTEM

Description

Circontrol Quick Charger Compact unit is able to charge all electric vehicles using DC CHAdeMO and AC standards. Charge your car while you take a cup of tea, it will not take longer than 15min.

Our Quick Chargers are equipped with dual technology allowing simultaneous charging of two cars making suitable for business and commercial fleets as well as petrol station along the roads. The Compact version has been adapted with latest communication protocols OCPP and XML.

Circontrol offers an innovative software based in SCADA for remote control and as a management tool.Charging operator can friendly access to status information, graphics and charge reports according historical data regis-tered.

Remote control and monitoring of the unit through standard XML & HTML

OCPP protocol integration

Ethernet 10/100BaseTX communication

Quick Charging in 15 minutes

8” LCD screen for user interaction

Start, Stop and emergency buttons

Light indications for status indication

RFID identi�cation and prepayment

Mode 3 and mode 4 locking mechanism

Real time energy metering

Time and consumption based prepayment modes

Simultaneous AC & DC charging with maximum demand control

Protecions rate IP55 IK10

Temperature range -30ºC to +45ºC

Protection against overloads, short-circuits and insulation faults with an automatic switch

EV standards: IEC 62196-3, IEC 61851-1, CHAdeMO

Harmonic �ltering

3G communications

User interface

Charging management

Security & Protection

Options

Communications and protocols

Page 30: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

30

.Catalogue 2013-2014

5

Technical Features

Accessories

Ref Code Description

CCL-QP-FIL 490065 Harmonic Filtering

CCL-QP-3G 460066 3G Modem

Accesories

Type Ref V in F Hz I in P in V out I outConnector

typeCharging

Mode

TechnicalFeatures

Page

Input Output

QPC

CCL-QPC

400VAC 50/60Hz +/- 5% 80 A 58 kVA 500V 120ADC JEVS G105 Mode 4 76

CCl-QPC-MIX

400VAC 50/60Hz +/- 5% 117 A 84 kVA

500VDC 120ADC JEVS G105 Mode 4

77

400VAC 32A Type 2 Mode 3

CCL-QPC-MIX 63

400VAC 50/60Hz +/- 5% 143 A 103 kVA

500VDC 120ADC JEVS G105 Mode 4

78

400VAC 63A Type 2 Mode 3

Page 31: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

31

5

Description

Circontrol CCQC (Compact combined quick charged) combine dual port 50kW DC and AC 43kW charger.

Designed to support dual protocol CHADEMO and CCS (com-bo 2) to cover all users needs, making suitable for business and commercial fleets as well as petrol station along the roads.

The Compact Combined version has been adapted with latest communica-tion protocols OCPP and XML. Circontrol offers an innovative software based in SCADA for remote control and as a management tool.

Charging operator can friendly access to status information, graphics and charge reports according historical data registered.

E5.3 QUICK CHARGING COMBO 2

Description

Remote control and monitoring of the unit through standard XML & HTML

OCPP protocol integration

Ethernet 10/100BaseTX communication

Technical Features

Quick Charging in 15 minutes

8” LCD screen for user interaction

Start, Stop and emergency buttons

Light indications for status indication

RFID identi�cation and prepayment

Mode 3 and mode 4 locking mechanism

Real time energy metering

Time and consumption based prepayment modes

Simultaneous AC & DC charging with maximum demand control

IP Rate: IP54

Temperature range -30ºC to +45ºC

Protection against overloads, short-circuits and insulation faults with an automatic switch

EV standards: IEC 62196-3, IEC 61851-1, CHAdeMO and CCS (combo 2)

User interface

Charging management

Communications and protocols

Security & Protection

Page 32: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

32

.Catalogue 2013-2014

5

Type Ref V in F Hz I in P in V out I outConnector

typeCharging

Mode

TechnicalFeatures

Page

Input Output

COMBO2 (CCS)

CCL-QPC-CCS

400VAC 50/60Hz +/- 5% 80 A 58 kVA 500V 120ADC JEVS G105 Mode 4 79

CCl-QPC-CH-CCS

400VAC 50/60Hz +/- 5% 80 A 58 kVA 500VDC

120ADC JEVS G105 Mode 4

80

120 ADC Type 2 COMBO Mode 3

CCL-QPC-CH-CCS-AC63

400VAC 50/60Hz +/- 5% 143 A 103 kVA

500 VDC

120ADC JEVS G105 Mode 4

81

500VDC 120ADC Type 2 COMBO Mode 4

400 VAC 63A Type 2 Mode 3

Technical features

Page 33: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

33

6

.Catalogue 2013-2014

Remote equipment monitoring and parameterisation.

Display of parameters and the status of devices in real time.

Records and prints historical logs in table or graph format.

Multipoint Web server and Built-in XML Server.

Creation of application access pro�les and users with a user and password.

Very versatile and easy to use.

Compatible with OPC software for PS/PSS.

Alarms module (events).

Creation of customised screens.

Optional control actions can be performed on units.

Report generator and energy bill simulator module, optional emulation of tariffs or hourly periods.

CirCarlife Scada represents an integral software solution that focuses on the control and parame-terisation of smart electric vehicle charging points and units. Nowadays, companies want centrali-sed control of the whole installation for manage-ment and maintenance purposes. CIRCONTROL’s CirCarlife Scada software can read the instanta-neous values of all CirCarlife units in real time and generate tables and historical logs of data that will be saved in the central processing unit (PC) so that this information can be studied later.

In addition, CirCarlife Scada can download all stored data to units with an internal memory.The user can fully control its charging network, checking information on the installation’s status and general consumption in real time. The user can generate custom screens and create alarms, events, reports, tables, etc. with the internal variables of the system.

Ref Code

CCL-SCADA 490052

Speci�cations

Technical Features

NEW

will be saved in the central processing unit (PC) so

In addition, CirCarlife Scada can download all stored data to units with an

Description

E.6 Management and control software

CirCarLifeIntelligent recharging solutions for electric vehicles

Page 34: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL- CirCarLife

34

.Catalogue 2013-2014

7

CDU-TCP

Description

The CDU-TCP is a device with the latest CIRCONTROL techno-logy, based on the CirCarLife Scada Software. Inside there is a microprocessor with 64Mb memory and driver routines for CIRCONTROL equipment. It can support up to 32 charging stations in its RS485 Bus, and through its Ethernet connec-tion you can access to the internal RS485 bus and the internal memory, remotely through e.g. Internet. It records and stores several weeks of data from connected equipment, in case of loss of communication with the control system (higher SCA-DA). Once retrieved the communication, the CDU-TCP returns the data stored in its memory to the control system (SCADA), preventing loss of data while there was no communication. This team is capable of being programmed to manage events (alarms) taking into account any parameter of any CIRCON-TROL unit connected to it.

The CDU-TCP does not store SCADA screens or reports. These must be on a PC with a superior SCADA, connected to one or more CDU-TCP who will be in charge of providing data to the SCADA.

E7.1 SMART STANDALONE DATA CENTRALISING UNIT

For the CDU-TCP programming, CirCarLife Scada EDITOR 3.0 or higher is required. After starting the Software installation, choose the custom option and install only the EDITOR. Follow steps to complete the installation. The next step is to electrica-lly connect the computers using the following scheme.

Requeriments

Connection example

E7. ACCESORIES

CirCarLifeIntelligent recharging solutions for electric vehicles

Page 35: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

35

7

Low energy consumption

Rigid aluminium box

Compact unit

High-speed processor (ARM 9)

10/100 Mbps Ethernet Port

Remote con�guration and management

Class 1 Div 2 Certi�ed

Supported Technologies (HSUPA, UMTS, EDGE, GPRS (MS-12), GSM)

Supported Bands:

· Three-band for UMTS/HSDPA/HSUPA

· 850/1900/2100 MHz

· Four-band GPRS/EDGE

· 850/900/1800/1900 MHz”

Temperature range: -30ºC to 70º C

The CirCarlife telecommunication accessories can be used to connect all units of the Circarlife range and establish commu-nications networks, even remotely. The user can remotely ma-nage the full display and control all equipment with the use of the CirCarlife Scada control and supervision software and 3G modem. Ideal for improving and reducing communication installations between outdoor and car park devices, where the installation and con�guration of cabling elements required for communications networks is not always a simple task.

Ref Code

MODEM-3G 490028

Speci�cations

Technical features

MODEM-3G

Description

E7.2 COMMUNICATIONACCESSORIES

Page 36: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

36

.Catalogue 2013-2014

7

SAFESYSTEM

E.7.3 PRE-PAYMENT SOLUTIONS

Description

CIRCONTROL supplies the necessary equipment to recharge the prepayment cards used to charge for the electricity service (software, card loader, RFID cards, pay station). The payment method can be done manually or automatically, using a pay station that includes note reader, coins and CirCarLife cards dispenser or PC software that allows you to charge the card with speci�c tariffs measured in kwh, credit. Restrictions of used also can be applied, etc.

1 Stand-alone terminal (CCL-TERM)

The Prepayment system uses proximity cards (credit card format) with precharged credits that will be discounted ac-cording to consumption. These cards can be recharged as often as desired, with different recharging ways to load ac-cording to needs.

Application

Pre-payment systems

Models

REF CODE DESCRIPTION

CCL-CARD 490012CirCarLife proximity cards without credits.

CCL-SOFT 490014 Software and USB reader

CCL-CARD20 490020CirCarLife proximity cards with 20 credits

CCL-CARD50 490021CirCarLife proximity cards with 50 credits

CCL-CARD90 490022CirCarLife proximity cards with 90 credits

CCL-TERM 490013Standalone terminal for recharging CirCarLife cards.

2 Software Pre-paid (CCL-SOFT)

CCL- CARD, CCL- TERM, CCL- Soft

Page 37: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

8

E8. Technical Features

CirCarLifeIntelligent recharging solutions for electric vehicles

37

Page 38: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

38

.Catalogue 2013-2014

8

Type CCL-WBC

Code 490074

Number of sockets 1

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current ** 16 A

Nomina input power 3,6kW

Required power supply capacity 3,6 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 3,6 kW

Maximum output current 16 A

AC output voltage 230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 1 cable tethered (UNE EN 62196-2)

Socket B -

General

Cable lenght 5 meters

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

Light beacon Three color led status

Net weight 4 Kg

Optional devices

Extended Temperature range Heater (-30 to + 45 °C)

* depending on local installation

Basic Wallbox Series - CCL-WBC

Page 39: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

39

8

Type CCL-WBC-32

Code 490123

Number of sockets 1

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current** 32 A

Nominal input pow 7,2 kW

Required power supply capacity 7,2 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 7,2 kW

Maximum output current 32 A

AC output voltage 230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851)

Type 1 (UNE EN 62196-2) cable tethered

General

Cable lenght 5 meters

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

Light beacon Three color led status

Net weight 4 Kg

Optional devices

Extended Temperature range Heater (-30 to + 45 °C)

**power limit control by software

Basic Wallbox Series - CCL-WBC-32

Page 40: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

40

.Catalogue 2013-2014

8

Type CCL-WB-MIX

Code 490076

Number of sockets 2

Input

AC power supply 1P + N + PE 3P + N + PE

AC Voltage 230 AC +/- 10% * 400 V AC +/- 10%

Nominal input current 48 A

Nominal input power 3,6 kW 22 kW

Required power supply capacity 3,6 kVA 22 kVA

Frequency 50 / 60 Hz -

Output

Maximum output power 7,2 kW (Socket A) 22 kW (Socket B)

Maximum output current 16 A (Socket A) 32 A (Socket B)

AC output voltage 230V AC +/- 10% 400V AC +/- 10%

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2)

Socket B Mode 1 & Mode 2CEE 7/4 (Schuko) or BS1363 (UK)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

Net weight 4 Kg

Optional devices

Extended Temperature range Heater (-30 to + 45 °C)

* depending on local installation

Basic Wallbox Series - CCL-WB-MIX

Page 41: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

41

8

Type CCL-WBM

Code 490072

Number of sockets 1

Input

AC power supply * 1P + N + PE 3P + N + PE

AC Voltage 230AC +/- 10% 400 V AC +/- 10%

Nominal input current ** 32 A 32 A

Nominal input power 7,2 k 21 kW

Required power supply capacity 7,2 kVA 21 kVA

Frequency 50 / 60 Hz 50 / 60 Hz

Output

Maximum output power 7,2 kW 21 kW

Maximum output current 32 A 32 A

AC output voltage 230 V AC +/- 10% 400 V AC +/- 10%

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-1)

Socket B -

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

Light beacon Three color led status

Net weight 4 Kg

Optional devices

Extended Temperature range Heater (-30 to + 45 °C)

* depending on local installation

**power limit control by software

Basic Wallbox Series - CCL-WBM

Page 42: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

42

.Catalogue 2013-2014

8

Type CCL-WBMC

Code 490133

Number of sockets 1

Input

AC power supply * 1P + N + PE 3P + N + PE

AC Voltage 230 V AC +/- 10% 400 V AC +/- 10%

Nominal input current ** 32 A

Nominal input power 7,2 kW 22 kW

Required power supply capacity 7,2 kVA 22 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 7,2 kW 22 kW

Maximum output current 32 A

AC output voltage 230 V AC +/- 10% 400 V AC +/- 10%

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-1)

Socket B -

General

Cable lenght 5 meters

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

Light beacon Three color led status

Net weight 4 Kg

Optional devices

Extended Temperature range Heater (-30 to + 45 °C)

* depending on local installation

**power limit control by software

Basic Wallbox Series - CCL-WBMC

Page 43: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

43

8

Type CCL-WBC-SMART

Code 490075

Number of sockets 1

Input

AC power supply 1P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current** 16 A

Nominal input power 3,6 kW

Required power supply capacity 3,68 kVA

Frequency 50 / 60 Hz

Output

Rated output power 3,6 kW

Rated output current* 16 A230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 1 (UNE EN 62196-2) tethered cable

Socket B -

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght 5 meters

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

Smart Wallbox Series - CCL-WBC-SMART

Page 44: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

44

.Catalogue 2013-2014

8

Type CCL-WBC32-SMART

Code 490124

Number of sockets 1

Input

AC power supply 1 P + N +PE

AC Voltage 230V AC +/- 10%

Nominal input current ** 32 A

Nominal input power 7,2 kW

Required power supply capacity 7,2 kVA

Frequency 50 / 60 Hz

Output

Rated output power 7,2 kW

Rated output current 32 A230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 1 cable tethered (UNE EN 62196-2)

Socket B -

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght 5 meters

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

**power limit control by software

Smart Wallbox Series - CCL-WBC32-SMART

Page 45: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

45

8

Type CCL-WBM-SMART

Code 490073

Number of sockets 1

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current** 32 A

Nomina input power 7,2 kW

Required power supply capacity 7,2 kVA

Frequency 50 / 60 Hz

Output

Rated output power 7,2 kW

Rated output current 32 A

AC output voltage 230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Socket B -

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

**power limit control by software

Smart Wallbox Series - CCL-WBM-SMART

Page 46: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

46

.Catalogue 2013-2014

8

Type CCL-WBS-SMART

Code 490079

Number of sockets 1

Input

AC power supply 1P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current** 16 A

Nominal input power 3,6 kW

Required power supply capacity 3,68 kVA

Frequency 50 / 60 Hz

Output

Rated output power 3,6 kW

Rated output current* 16 A

AC output voltage 230 V AC 1P + N

Charge system

Socket A Mode 1 & Mode 2CEE 7/4 (Schuko) or BS1363 (UK)

Socket B -

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

**Power limit control by software

Smart Wallbox Series - CCL-WBS-SMART

Page 47: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

47

8

Type CCL-WB-MIX-SMART

Code 490077

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current** 48 A

Nomina input power 11 kW

Required power supply capacity 11 kVA

Frequency 50 / 60 Hz

Output

Rated output power 7,2 kW (Socket A)3,6 kW (Socket B)

Rated output current* 32 A (Socket A) 16 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851) Type 2 (UNE EN 62196-2) Lock plug system

Socket B Mode 1 & Mode 2CEE 7/4 (Schuko) or BS1363 (UK)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

**power limit control by software

Smart Wallbox Series - CCL-WB-MIX-SMART

Page 48: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

48

.Catalogue 2013-2014

8

Type CCL-WB2M-SMART

Code 490106

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current** 64 A

Nomina input power 15 kW

Required power supply capacity 15 kVA

Frequency 50 / 60 Hz

Output

Rated output power 7,2 kW (Socket A)7,2 kW (Socket B)

Rated output current 32 A (Socket A)32 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Socket B Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

**power limit control by software

Smart Wallbox Series - CCL-WB2M-SMART

Page 49: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

49

8

Type CCL-WBM-SMART-TRI

Code 490089

Number of sockets 1

Input

AC power supply 3P + N + PE

AC Voltage 400 V AC +/- 10%

Nominal input current** 32 A

Nomina input power 22 kW

Required power supply capacity 22,1 kVA

Frequency 50 / 60 Hz

Output

Rated output power 22 kW

Rated output current 32 A

AC output voltage 400 V AC 3P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Socket B -

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

Smart Wallbox Series - CCL-WBM-SMART-TRI

Page 50: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

50

.Catalogue 2013-2014

8

Type CCL-WB-MIX-SMART-TRI

Code 490090

Number of sockets 2

Input

AC power supply 3P + N + PE

AC Voltage 230 V AC or 400 V AC +/- 10% *

Nominal input current** 48 A

Nomina input power 25 kW

Required power supply capacity 25,7 kVA

Frequency 50 / 60 Hz

Output

Rated output power 22 kW (Socket A)3,6 kW (Socket B)

Rated output current 32 A (Socket A)16 A (Socket B)

AC output voltage 400 V AC +/- 10%

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Socket B Mode 1 & Mode 2CEE 7/4 (Schuko) or BS1363 (UK)

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

**power limit control by software

Smart Wallbox Series - CCL-WB-MIX-SMART-TRI

Page 51: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

51

8

Type CCL-WB2M-SMART-TRI

Code 490107

Number of sockets 2

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current ** 64 A

Nominal input power 44 kW

Required power supply capacity 44,2 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 22 kW (Socket A)22 kW (Socket B)

Maximum output current 32 A (Socket A)32 A (Socket B)

AC output voltage 400 V AC 3P + N

Charge system

Socket A Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Socket B Mode 3 (IEC 61851)Type 2 (UNE EN 62196-2) Lock plug system

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Cable lenght -

Enclosure rating IP 54 / IK 10

Enclosure material ABS plastic

Installation mode Simple installation, 4-point wall�xing

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Operating temperature -10 to +45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Interface protocol OCCP / XML

Net weight 4 Kg

Optional devices

Wireless Comunication 3G / GPRS

Extended Temperature range -30 to +45 °C (Heater system included)

* Adjustable power limit control

**power limit control by software

Smart Wallbox Series - CCL-WB2M-SMART-TRI

Page 52: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

52

.Catalogue 2013-2014

8

Type CCL-PE1-COM

Code 490000

Number of sockets 1

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current 16 A

Nominal input power 3,6 kW

Required power supply capacity 3,68 kVA

Frequency 50 / 60 Hz

Output

Rated output power 3,6 kW

Rated output current 16 A

AC output voltage 230 V AC 1P + N

Charge system

Mode Mode 1 & Mode 2

Socket A CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB

Safety Protection RCD 30mA autorecovery (class A)

Energy meter

Integrated meter

Network connection

Bus RS-485

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Socket protection Socket lock with mobile head

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display 2 units of 7 segments display

Net weight 40 Kg

Optional devices

Wireless Comunication -

RCD Protection RCD class B

MCB Autorecovery

Charging Post Basic Series - CCL-PE1-COM

Page 53: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

53

8

Type CCL-PE2-COM

Code 490025

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current 32 A

Nominal input power 7,2 kW

Required power supply capacity 7,36 kVA

Frequency 50 / 60 Hz

Output

Rated output power 3,6 kW (Socket A)3,6 kW (Socket B)

Rated output current 3,6 kW (Socket B)16 A (Socket A)

AC output voltage 230 V AC 1P + N

Charge system

Mode Mode 1 & Mode 2

Socket A CEE 7/4 (Schuko) or BS1363 (UK)

Socket B CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Integrated meter

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Bus RS-485

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Socket protection Socket lock with mobile head

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display 2 units of 7 segments display

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol XML

Net weight 40 Kg

Optional devices

Wireless Comunication 3G

RCD Protection RCD class B

MCB Autorecovery

Charging Post Basic Series - CCL-PE2-COM

Page 54: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

54

.Catalogue 2013-2014

8

Type CCL-PE2-IP

Code 490026

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current 32 A

Nominal input power 7,2 kW

Required power supply capacity 7,59 kVA

Frequency 50 / 60 Hz

Output

Rated output power 3,6 kW (Socket A)3,6 kW (Socket B)

Rated output current 16 A (Socket A)16 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Mode Mode 1 & Mode 2

Socket A CEE 7/4 (Schuko) or BS1363 (UK)

Socket B CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Integrated meter

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus RS-485

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Socket protection Socket lock with mobile head

Operating temperature -30 to + 45°C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display 2 units of 7 segments display

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol XML

Net weight 40 Kg

Optional devices

Wireless comunication 3G

RCD protection RCD class B

MCB Autorecovery

Charging Post Basic Series - CCL-PE2-IP

Page 55: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

55

8

Type CCL-PE2-MOV

Code 490027

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230 V AC +/- 10%

Nominal input current 32 A

Nominal input power 7,2 kW

Required power supply capacity 7,36 kVA

Frequency 50 / 60 Hz

Output

Rated output power 3,6 kW (Socket A)3,6 kW (Socket B)

Rated output current 16 A (Socket A)16 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Mode Mode 1 & Mode 2

Socket A CEE 7/4 (Schuko) or BS1363 (UK)

Socket B CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB autorecovery

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Integrated meter

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus RS-485

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Socket protection Socket lock with mobile head

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display 2 units of 7 segments display

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol XML

Net weight 40 Kg

Optional devices

Wireless Comunication 3G

RCD Protection RCD class B

Charging Post Basic Series - CCL-PE2-MOV

Page 56: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

56

.Catalogue 2013-2014

8

Charging Post Smart Series -CCL-PM3-URBAN

Type CCL-PM3-URBAN

Code 490135

Number of sockets 2

Input

AC power supply 1 P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current * 64 A

Nominal input power 15 kW

Required power supply capacity 15 kVA

Frequency 50 / 60 Hz

Output

Maximumoutput power 7,3 kW (Socket A) 7,3 kW (Socket B)

Maximumoutput current* 32 A (Socket A) 32 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Socket A Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket B Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protection Transient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Page 57: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

57

8

Charging Post Smart Series -CCL-PM-MIX-URBAN

Type CCL-PM-MIX-URBAN

Code 490136

Number of sockets 2

Input

AC power supply 1 P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current* 48 A

Nominal input power 11 kW

Required power supply capacity 11,5 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 7,3 kW (Socket A) 3,6 kW (Socket B)

Maximumoutput current* 32 A (Socket A) 16 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Socket A Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket B CEE 7/4 (Schuko) or BS1363 (UK) Mode 1 & Mode 2

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Operating temperature -30 to + 45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protection Transient surge protector Type 2 (EN 61643-11)"

* Adjustable power limit control

Page 58: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

58

.Catalogue 2013-2014

8

Type CCL-PM-MIX4-URBAN

Code Check availability

Number of sockets 4

Input

AC power supply 1 P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current * 64 A

Nominal input power 15 kW

Required power supply capacity 15 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 7,3 kW (Socket A1)

3,6 kW (Socket A2)

7,3 kW (Socket B1)

3,6 kW (Socket B2)

Maximum output current* 32 A (Socket A1)

16 A (Socket A2)

32 A (Socket B1)

16 A (Socket B2)

AC output voltage 230 V AC 1P + N + PE

Charge system

Socket A1 Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket A2 CEE 7/4 (Schuko) or BS1363 (UK) Mode 1 & Mode 2

Socket B1 Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket B2 CEE 7/4 (Schuko) or BS1363 (UK) Mode 1 & Mode 2

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Operating temperature -30 to + 45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PM-MIX4-URBAN

Page 59: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

59

8

Charging Post Smart Series -CCL-PT3-URBAN

Type CCL-PT3-URBAN

Code 490138

Number of sockets 2

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current * 64 A

Nominal input power 42 kW

Required power supply capacity 43,5 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 21 kW (Socket A) 21 kW (Socket B)

Maximum output current* 32 A (Socket A) 32 A (Socket B)

AC output voltage 400 V AC 3P + N

Charge system

Socket A Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket B Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Operating temperature -30 to + 45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Page 60: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

60

.Catalogue 2013-2014

8

Type CCL-PT-MIX-URBAN

Code 490139

Number of sockets 2

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current * 48 A

Nominal input power 11 kW

Required power supply capacity 11,5 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 21 kW (Socket A) 3,6 kW (Socket B)

Maximumoutput current32 A (Socket A) 16 A (Socket B)

AC output voltage 400 V AC 3P + N (Socket A) 230 V AC 1P + N (Socket B)

Charge system

Socket A Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket B CEE 7/4 (Schuko) or BS1363 (UK) Mode 1 & Mode 2

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Operating temperature -30 to + 45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PT-MIX-URBAN

Page 61: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

61

8

Type CCL-PT-MIX4-URBAN

Code 490137

Number of sockets 4

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current * 64 A

Nominal input power 44 kW

Required power supply capacity 44,3 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 22 kW (Socket A1)

11 kW (Socket A2)

22 kW (Socket B1)

11 kW (Socket B2)

Maximum output current 32 A (Socket A1)

16 A (Socket A2)

32 A (Socket B1)

16 A (Socket B2)

AC output voltage 400 V AC 3P + N (Socket A1 & B1)

230 V AC 1P + N (Socket B2 & A2 )

Charge system

Socket A Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket B CEE 7/4 (Schuko) or BS1363 (UK) Mode 1 & Mode 2

Socket C Type 2 (UNE EN 62196-2) lock system Mode 3 (IEC 61851)

Socket D CEE 7/4 (Schuko) or BS1363 (UK) Mode 1 & Mode 2

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Stainless steel

Operating temperature -30 to + 45 °C

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PT-MIX4-URBAN

Page 62: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

62

.Catalogue 2013-2014

8

Type CCL-PM1

Code 490080

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current* 32 A

Nominal input power 7,3 kW

Required power supply capacity 7,3 kVA

Frequency 50 / 60 Hz

Output

Maximum output power3,6 kW (Socket A) 3,6 kW (Socket B)

Maximum output current16 A (Socket A) 16 A (Socket B)"230 V AC 1P + N (Socket B)

Charge system

Socket A Mode 1 & Mode 2 CEE 7/4 (Schuko) or BS1363 (UK)

Socket B Mode 1 & Mode 2 CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Polyurethane casing

Socket protection Vandal metal doors

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PM1

Page 63: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

63

8

Type CCL-PM3

Code 490081

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current* 64 A

Nominal input power 14,4 kW

Required power supply capacity 14,5 kVA

Frequency 50 / 60 Hz

Output

Maximum output power7,3 kW (Socket A)7,3 kW (Socket B)

Maximum output current32 A (Socket A)32 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Socket AMode 3 (IEC 61851)Type 2 (UNE EN 62196-2) lock system

Socket BMode 3 (IEC 61851)Type 2 (UNE EN 62196-2) lock system

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Polyurethane casing

Socket protection Vandal metal doors

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PM3

Page 64: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

64

.Catalogue 2013-2014

8

Type CCL-PM-MIX

Code 490082

Number of sockets 2

Input

AC power supply 1P + N + PE

AC Voltage 230V AC +/- 10%

Nominal input current* 48 A

Nominal input power 11 kW

Required power supply capacity 11 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 7,3 kW (Socket A) 3,6 kW (Socket B)

Maximum output current* 32 A (Socket A) 16 A (Socket B)

AC output voltage 230 V AC 1P + N

Charge system

Socket AMode 3 (IEC 61851)Type 2 (UNE EN 62196-2) lock system

Socket BMode 1 & Mode 2CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class B - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus RS-485 (Modbus)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Polyurethane casing

Socket protection Vandal metal doors

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PM-MIX

Page 65: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

65

8

Type CCL-PT3

Code 490083

Number of sockets 2

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current* 64 A

Nominal input power 42 kW

Required power supply capacity 44,2 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 21 kW (Socket A) / 21 kW (Socket B)

Maximum output current* 32 A (Socket A) / 32 A (Socket B)

AC output voltage 400 V AC 3P + N

Charge system

Socket AMode 3 (IEC 61851)Type 2 (UNE EN 62196-2) lock system

Socket BMode 3 (IEC 61851)Type 2 (UNE EN 62196-2) lock system

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus RS-485 (Modbus)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Polyurethane casing

Socket protection Vandal metal doors

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PT3

Page 66: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

66

.Catalogue 2013-2014

8

Type CCL-PT-MIX

Code 490084

Number of sockets 2

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current* 48 A

Nominal input power 25 kW

Required power supply capacity 25,7 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 21 kW (Socket A) 3,6 kW (Socket B)

Maximum output current*32 A (Socket A) 16 A (Socket B)

AC output voltage 400 V AC 3P + N (Socket A) 230 V AC 1P + N (Socket B)

Charge system

Socket A Mode 3 (IEC 61851) Type 2 (UNE EN 62196-2) lock system

Socket B Mode 1 & Mode 2 CEE 7/4 (Schuko) or BS1363 (UK)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX

Bus RS-485 (Modbus)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Polyurethane casing

Socket protection Vandal metal doors

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post Smart Series -CCL-PT-MIX

Page 67: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

67

8

Type CCL-PT3-63

Code 490126

Number of sockets 1

Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 10%

Nominal input current* 63 A

Nominal input power 43 kW

Required power supply capacity 43,6 kVA

Frequency 50 / 60 Hz

Output

Maximum output power 43 kW (Socket A)

Maximum output current* 63 A (Socket A)

AC output voltage 400 V AC 3P + N

Charge system

Socket A Mode 3 (IEC 61851)

Type 2 tethered cable (UNE EN 62196-2)

Electrical protections

Overcurrent protections MCB autorecovery

Safety protection RCD 30mA autorecovery (class A)

Energy meter

Acuracy class in active energy Class 1 - EN50470-3

Accuracy class in reactive energy Class 2 - EN62053-23

Meter standards EN62052-11, EN62053-21, EN62053-23, EN61010-1

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Enclosure rating IP 54 / IK 10

Enclosure material Polyurethane casing

Socket protection Vandal metal doors

Operating temperature -30 to + 45 °C (Heater system included)

Operating humidity To 95% RH Non-condensing

RFID system ISO / IEC14443A / B

Display LCD Backlight double line text

Rear Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Interface protocol OCCP / XML

Net weight 65 Kg

Optional devices

Wireless Comunication 3G / GPRS

RCD Protection RCD class B

Overvoltage protectionTransient surge protector Type 2 (EN 61643-11)

* Adjustable power limit control

Charging Post- CCL-PT3-63

Page 68: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

68

.Catalogue 2013-2014

8

Charging Post - 2 Wheel Series

Type CCL-CB3 IP CCL-CB6 IP

Code 490037 490039

Number of plugs 3 6

Power input 230Vac 1P+ N 230Vac 1P+ N + PE

Tolerance ±10% ±10%

Frequency input 50..60Hz 50..60Hz

Power output 230Vac 230Vac

Maximum consumption per outlet 9,2 kW 18,4 kW

Maximum current output 16A 16A

Connector Schuko CEE 7/4 Schuko CEE 7/4

Charging mode Mode 1 Mode 1

Current metering Integrated meter

RCCB Self-reclosing system

RFID reader ISO 14443A

RFID frequency 13,56MHz

Regulations EN 61851-1 : 2001 part 1

IEC 61000, IEC 60364-4-41, IEC 61008 – 1, IEC 60884-1, IEC 60529, IEC61010

UNE-EN55011, UNE-EN62196-1, UNE-EN61851-1, UNE-EN61851-21, UNE-EN61851-22

ISO 14443A

Temperature range -10 ... +45 ºC

IP protection IP 54

Surround FE ST37 2mm thickness

Surface Grey polyester paint RAL 9006 with anti-graf�ti coat

Anchor Floor �xing

Individual Technical features

MODEL CCL-MO3

Maximum consumption 11 kW

Number of outlets 3

Weight 46Kg

Dimensions 2,9m ; 0,3m

MODEL CCL-MO6

Maximum consumption 22 kW

Number of outlets 6

Weight 67Kg

Dimensions 4,2m ; 0,3m

Page 69: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

69

8

Multipoint Controller - CCL-CM

Type CCL-CM

Code 490015

Power Supply

Input voltage 230V AC 1P+N+PE

Nominal input power 60W

Input frequency 50/60Hz

Network connection

LAN network Ethernet RJ45

SL charging point RS485 Modbus

Scalable master WB control 32 WB points

General

Enclosure Material Steel metalic body

Operating temperature -10 to +45cº

Operating Humidity To 95% RH Non-condensing

RFID reader system ISO/IEC14443A/B

LCD Display 10.4" XGA TFT LCD touch screen

Interface Integration protocol OCPP / XML

Power limit control Maximum demand management

Net weight 6kg

Software

OS Linux operation system

Scada management control Circarlife scada

Optional devices

Wireless Comunication 3G/GPRS

Extended Temperature range Heater (-30 to +50Cº)

Meter Utility company own meter

AC Analyzer AC Power Quality Analyzers

Harmonics Active harmonic �lter

Page 70: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

70

.Catalogue 2013-2014

8

Multipoint Sockets - CCL-WB-SL Single phase

Type CCL-WB-SL CCL-WBM SL CCL-WBC 16 SL CCL-WBC 32 SL CCL-WB-SL-MIX

Code 490091 490092 490057 490125 490094

Number of plugs 1 1 1 1 2

Outputs

Rated output current 16A 32A 16A 32A 32A (Socket A) 16A (Socket B)

Rated output 3,6kW 7,2kW 3.6kW 7.2kW 7.2kW (Socket A)3.6kW (Socket B)

Output AC voltage 230V AC 1P+N+PE 230V AC 1P+N+PE

230V AC 1P+N+PE 230V AC 1P+N+PE 230V AC 1P+N+PE

Inputs

Input voltage 230V AC 1P+N 230V AC 1P+N 230V AC 1P+N 230V AC 1P+N 2 x 230V AC 1P+N

Nominal input current 16A 32A 16A 32A 32A 16A

Nominal input power 3,6kW 7,2kW 3.6kW 7,2kW 25kW

Input frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz

Charge system

Socket A Mode 1 & Mode 2 Mode 3 (IEC 61851)

Mode 3 (IEC 61851) Mode 3 (IEC 61851) Mode 3 (IEC 61851)

Socket B - - - - Mode 1 & Mode 2

Sockets

Socket A CEE 7/4 (Schuko) or BS1363 (UK)

Type 2 (UNE EN 62196-2)

Type 1 (UNE EN 62196-2)

Type 1 (UNE EN 62196-2)

Type 2 (UNE EN 62196-2) lock system

Socket B - - - - CEE 7/4 (Schuko) or BS1363 (UK)

Energy Meter

Internal meter

Cable

Cable lenght - - 5 meters 5 meters -

Cable support - - Metal cable support Metal cable support -

Network connection

RS485 (scalable) Modbus

General

Energy Meter Internal meter

Enclosure Rating IP54 /IK10

Enclosure Material ABS

Operating Temperature -10 to +45Cº

Operating Humidity To 95% RH Non-condensing

Net Weight 4kg

Light beacon Three color led Status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Optional devices

Extended range tempe-rature

Heater (-30 to +50Cº)

RFID reader System ISO/IEC14443A/B

Connector Lock System - Type 2 connector hook

- - Type 2 connector hook

Page 71: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

71

8

Multipoint Sockets - CCL-WB-SL Three phase

Type CCL-WBM-SL TRI CCL-WB-SL MIX TRI

Code 490093 490095

Number of plugs 1 2

Outputs

Rated output current

32A 32A (Socket A)16A (Socket B)

Rated output power 21kW 21kW (Socket A)3.6kW (Socket B)

Output AC voltage 400V AC 3P+N+PE 400V AC 3P+N (Socket A) 230V AC 1P+N (Socket B)

Input

Input voltage 400V AC 3P+N 400V AC 3P+N (Socket A) 230V AC 1P+N (Socket B)

Nominal input current 1 x 32A 32A 16A

Nominal input power* 22kW 25kW

Input frequency 50/60Hz 50/60Hz

Charge system

Socket A Mode 3 (IEC 61851) Mode 3 (IEC 61851)

Socket B - Mode 1 & Mode 2

Sockets

Socket A Type 2 (UNE EN 62196-2) Type 2 (UNE EN 62196-2) lock system

Socket B - CEE 7/4 (Schuko) or BS1363 (UK)

Energy Meter Internal meter

Network connection

RS485 (scalable) Modbus

General

Enclosure Rating IP54 /IK10

Enclosure Material ABS

Operating temperature -10 to +45cº

Operating Humidity To 95% RH Non-condensing

Light beacon Three color led status

Power limit control Mode 3 PWM control according ISO/IEC 61851-1

Net weight 4kg

Optional devices

Extended Temperature range Heater (-30 to +50Cº)

RFID reader System ISO/IEC14443A/B

Connector Lock System Type 2 connector hook

Page 72: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

72

.Catalogue 2013-2014

8

Quick Charge Advance CCL-QP1

Type CCL-QPM

Code 490064

AC Input

AC power supply 3P + PE + N

AC Voltage 400V AC +/- 5%

Nominal input current 80 A (software limit control)

Required power supply capacity 58 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50/60 Hz

AC Output (to charging post)

AC power supply 1P + N + PE

Output voltage 230 V AC

DC Output (to charging post)

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

General

Enclosure rating IP44 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

Operational noise < 55 dBA

Compliance CHAdeMO / CE rev.0.9 certi�ed

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Cooling system Air Cooling fans

Isulating system High frequency transformer isolation

Net weight 440Kg

Optional devices

Enclosure rating kit Kit IP55

Armonic Filter (Current) <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

COMMUNICATION

POST POWER UNIT< <

Type CCL-QP1

Code 490061

AC Input (From power unit)

AC power supply 1P + PE + N

AC Voltage 230V AC +/- 5%

DC Input (From power unit)

Maximum input current 125 A

Maximum input power 50 kW

DC Output

Maximum output current 125A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Charge system

Mode charge Mode 4 (IEC-61851-23/24)

Plug type Plug type: JEVS G105 (IEC-92196-3)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus* RS-485 (Modbus)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP54 / IK10

Enclosure material Polyurethane IK10 vandal-proof

Operating temperature -30 ° to + 60 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control Software DC limit option

DC Cable lenght 3 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 280mm x 380mm x 1590mm

Weight 80kg

Optional devices

Wireless Comunication 3G/GPRS/GSM

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

* Communications from Power unit to charge post unit

POWER

<<

Page 73: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

73

8

Technical characteristics

COMMUNICATION

POWER UNIT< <POWER

Technical characteristics

Quick Charge Advance CCL-QP-MIX

Technical characteristics

POST

Type CCL-QP-MIX

Code 490063

AC Input (From power unit)

AC power supply 3P + PE + N

AC Voltage 400V AC +/- 5%

DC Input (From power unit)

Maximum input current 125 A

Maximum input power 50 kW

AC output

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Maximum AC current 32 A

Maximum AC power 22 kW

DC output

DC Voltage 50 - 500 V

Maximum DC current 125 A

Maximum DC power 50 kW

Charge system

DC charge Mode 4 (IEC-61851-23/24)Plug type: JEVS G105 (IEC-92196-3)

AC charge Mode3 (IEC61851-1) Socket: Type 2 (IEC6296)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus* RS-485 (Modbus)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Polyurethane IK10 vandal-proof

Operating temperature -30 ° to + 60 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control Software DC limit option

DC Cable lenght 3 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 280mm x 380mm x 1590mm

Weight 90kg

Optional devices

Wireless Comunication 3G/GPRS/GSM

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

* Communications from Power Unit to Charge Post Unit

Type CCL-QPM-MIX

Code 490100

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 117 A (software limit control)

Required power supply capacity 84 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50/60 Hz

AC Output (to charging post)

AC power supply 3P + N + PE

Output voltage 400 VAC

Maximum AC current 32 A

Maximum AC power 22 kW

DC Output (to charging post)

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 2 x 50 - 500 VDC

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

General

Enclosure rating IP44 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

Operational noise < 55 dBA

Compliance CHAdeMO / CE rev.0.9 certi�ed

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Cooling system Air Cooling fans

Isulating system High frequency transformer isolation

Net weight 440Kg

Optional devices

Enclosure rating kit Kit IP55

Armonic Filter (Current) <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

Page 74: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

74

.Catalogue 2013-2014

8

Quick Charge Advance CCL-QP-MIX-63

Type CCL-QP-MIX-63

Code 490120

AC Input (From power unit)

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

DC Input (From power unit)

DC Voltage range 50 - 500 V

Maximum DC current 125 A

Maximum DC power 50 kW

AC Input (From power unit)

Maximum AC current 63 A

Maximum AC power 21 kW

DC Output

DC Voltage range 50 - 500 V

Maximum DC current 125 A

Maximum DC power 50 kW

Charge system

DC charge Mode 4 JEVS G105 (CHAdeMO)

AC charge Mode3 (IEC61851-1) Type 2 Plug (IEC6296)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus* RS-485 (Modbus)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Polyurethane IK10 vandal-proof

Operating temperature -30 ° to + 60 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control Software DC limit option

DC Cable lenght 3 meters

AC Cable lenght 5 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 280mm x 380mm x 1590mm

Weight 90kg

Optional devices

Wireless Comunication 3G/GPRS/GSM

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

*Communications from Power Unit to Charge Post Unit

Type CCL-QPM-MIX-63

Code 490121

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 143 A (software limit control)

Required power supply capacity 103 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

AC Output (to charging post)

AC power supply 3P + N + PE

Output voltage 400 V AC

Maximum AC current 63 A

Maximum AC power 43 kW

DC Output (to charging post)

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

General

Enclosure rating IP44 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

Operational noise < 55 dBA

Compliance CHAdeMO / CE rev.0.9 certi�ed

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Cooling system Air Cooling fans

Isulating system High frequency transformer isolation

Net weight 440 Kg

Optional devices

Enclosure rating kit Kit IP55

Armonic Filter (Current) <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

COMMUNICATION

POWER UNIT< <POWERPOST

Page 75: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

75

8

Type CCL-QPM

Code 490064

AC Input

AC power supply 3P + PE + N

AC Voltage 400V AC +/- 5%

Nominal input current 80 A (software limit control)

Required power supply capacity 58 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50/60 Hz

AC Output (to charging post)

AC power supply 1P + N + PE

Output voltage 230 V AC

DC Output (to charging post)

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

General

Enclosure rating IP44 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

Operational noise < 55 dBA

Compliance CHAdeMO / CE rev.0.9 certi�ed

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Cooling system Air Cooling fans

Isulating system High frequency transformer isolation

Net weight 440Kg

Optional devices

Enclosure rating kit Kit IP55

Armonic Filter (Current) <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

Technical characteristics

COMMUNICATION

POWER UNIT< <POWER

Technical characteristics

POST

Quick Charge Advance CCL-QP2

Type CCL-QP2

Code 490062

AC Input (From power unit)

AC power supply 1P + PE + N

AC Voltage 230V AC +/- 5%

DC Input (From power unit)

Maximum input current 2 x 125 A

Maximum input power 2 x 50 kW

DC Output

Maximum output current 2 x 125A

Maximum output power 2 x 50 kW

Output voltage range 50 - 500 VDC

Charge system

Mode charge Mode 4 (IEC-61851-23/24)

Plug type Plug type: JEVS G105 (IEC-92196-3)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

Bus* RS-485 (Modbus)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP54 / IK10

Enclosure material Polyurethane IK10 vandal-proof

Operating temperature -30 ° to + 60 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control Software DC limit option

DC Cable lenght 3 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 280mm x 380mm x 1590mm

Weight 80kg

Optional devices

Wireless Comunication 3G/GPRS/GSM

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

* Communications from Power unit to charge post unit

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

* Communications from Power unit to charge post unit

Page 76: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

76

.Catalogue 2013-2014

8

Quick Charge Compact- CCL-QPC

Type CCL-QPC

Code 490098

Number of plugs 1

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 80 A (software limit control)

Required power supply capacity 58 kVA

Power Factor > 0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

DC Output

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Charge system

Mode charge Mode 4 (IEC-61851-23/24)

Plug type JEVS G105 (IEC-92196-3)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-conden-sing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control AC & DC by software

DC Cable lenght 3 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Weight 450kg

Isulating system High frequency transformer isolation

Cooling system Air Cooling fans

Optional devices

Wireless Comunication 3G/GPRS/GSM

Armonic Filter <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

Page 77: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

77

8

Quick Charge Compact- CCL-QPC-MIX

Type CCL-QPC-MIX

Code 490099

Number of plugs 2

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 117 A (software limit control)

Required power supply capacity

84 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

DC Output

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

AC Output

Maximum output current 32 A

Maximum output power 21 kW

Output voltage range 400V AC 3P + N + PE

Charge system

DC charge Mode 4 (IEC-61851-23/24)JEVS G105 (IEC-92196-3)

AC charge Mode3 (IEC61851-1) Type 2 Plug (IEC6296)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Operational noise < 55 dBA

Power limit control AC & DC by software

DC Cable lenght 3 meters

AC Cable lenght 5meters

Lights for status indication Three color led status

Interface protocol OCCP / XML

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Weight 440kg

Cooling system Air Cooling fans

Isulating system High frequency transformer isolation

Optional devices

Wireless Comunication 3G/GPRS/GSM

Armonic Filter <13% THD

MiD certi�ed AC meter Active Energy Class B Reactive Energy Class 2.0

Page 78: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

78

.Catalogue 2013-2014

8

Quick Charge Compact- CCL-QPC-MIX 63

Type CCL-QPC-MIX 63

Code 490128

Number of plugs 2

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 143 A (software limit control)

Required power supply capacity

103 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

DC Output

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

AC Output

Maximum output current 63 A

Maximum output power 43 kW

Output voltage range 400V AC 3P + N + PE

Charge system

DC charge Mode 4 (IEC-61851-23/24)JEVS G105 (IEC-92196-3)

AC charge Mode3 (IEC61851-1) Type 2 (IEC6296) tethered cable

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Compliance CHAdeMO / CE rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage

-20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Operational noise < 55 dBA

Power limit control AC & DC by software

DC Cable lenght 3 meters

AC Cable lenght 5meters

Lights for status indication Three color led status

Interface protocol OCCP / XML

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Weight 450kg

Cooling system Air Cooling fans

Isulating system High frequency transformer isolation

Optional devices

Wireless Comunication 3G/GPRS/GSM

Armonic Filter <13% THD

MiD certi�ed AC meter Active Energy Class B Reactive Energy Class 2.0

Page 79: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

79

8

Quick Charge Combo CCL-QPC-CCS

Type CCL-QPC-CCS

Code 490146

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 80 A (software limit control)

Required power supply capacity 58 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

DC Output

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Charge system

DC charge Mode 4 (IEC-61851-23/24)

Type Combo-2(DIN 70121)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autoreco-very (class A)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Compliance CE / Combo-2 (DIN 70121) EN61851-23

Enclosure rating IP55 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Hea-ter system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control DC by software

DC Cable lenght 3 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Weight 440kg

Isulating system High frequency trans-former isolation

Cooling system Air Cooling fans

Optional devices

Wireless Comunication 3G/GPRS/GSM

Armonic Filter <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

Page 80: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

80

.Catalogue 2013-2014

8

Quick Charge Combo CCL-QPC-CH-CCS

Type CCL-QPC-CH-CCS

Code 490147

Number of plugs 2

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 80 A (software limit control)

Required power supply capacity 58 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

DC Output

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

Charge system

DC Charge 1 Mode 4 (IEC-61851-23/24)

Combo-2 (DIN 70121)

DC Charge 2 Mode 4 (IEC-61851-23/24)

JEVS G105 (IEC-92196-3)

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Compliance CE / Combo-2 (DIN 70121) EN61851-23

CHAdeMO rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control DC by software

DC Cable lenght 3 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Weight 440kg

Isulating system High frequency transfor-mer isolation

Cooling system Air Cooling fans

Optional devices

Wireless Comunication 3G/GPRS/GSM

Armonic Filter <13% THD

MiD certi�ed AC meter Active Energy Class B, Reactive Energy Class 2.0

Page 81: Circontrol Circarlife Catalogue 2013 2014 - EV Charging Stations

CIRCONTROL - CirCarLife

.Catalogue 2013-2014

81

8

Quick Charge Combo CCL-QPC-CH-CCS-AC63

Type CCL-QPC-CH-CCS-AC63

Code 490148

Number of plugs 3

AC Input

AC power supply 3P + N + PE

AC Voltage 400V AC +/- 5%

Nominal input current 143 A (software limit control)

Required power supply capacity 103 kVA

Power Factor >0,96

Ef�ciency 95 % at nominal output power

Frequency 50 / 60 Hz

DC Output

Maximum output current 125 A

Maximum output power 50 kW

Output voltage range 50 - 500 VDC

AC Output

Maximum output current 63 A

Maximum output power 43 kW

Output voltage range 400V AC 3P + N + PE

Charge system

DC Charge 1 Mode 4 (IEC-61851-23/24)Combo-2 (DIN 70121)

DC Charge 2 Mode 4 (IEC-61851-23/24)JEVS G105 (IEC-92196-3)

AC charge Mode3 (IEC61851-1) Type 2 (IEC6296) tethered cable

Electrical protections

Overcurrent protections MCB

Safety protection RCD 30mA autorecovery (class A)

Network connection

Ethernet 10/100BaseTX (TCP-IP)

General

Compliance CE / Combo-2 (DIN 70121) EN61851-23CHAdeMO rev.0.9 certi�ed

Enclosure rating IP55 / IK10

Enclosure material Zinced steel

Operating temperature -30 ° to + 45 °C (Heater system included)

Ambient temperature storage -20 to +60Cº

Operating humidity 30 to 90 % RH Non-condensing

RFID system ISO / IEC14443A / B

Display 8" HMI

Power limit control AC & DC by software

DC cable lenght 3 meters

AC cable lenght 5 meters

Lights for status indication RGB colors indicator

Interface protocol OCCP / XML

Dimensions (D x W x H) 780mm x 650mm x 2060mm

Weight 445 Kg

Isulating system High frequency transfor-mer isolation

Cooling system Air Cooling fans

Optional devices

Wireless Comunication 3G/GPRS/GSM

Armonic Filter <13% THD

MiD certi�ed AC meter Active Energy Class B Reactive Energy Class 2.0