1
E-501 V-501 V-502 C-502 C-501 C-503 E-502 E-503 S-5001 S-5002 S-5003 S-5004 S-5005 S-5006 S-5007 S-5008 S-5009 S-5010 S-5011 S-5012 S-5013 S-5015 S-5016 TIC I-1 Cold Water Used Cold Water 17 atm 93.3 C 17 atm 65.5 C 41 atm 166 C 41 atm 87.8 C 40 atm 78.8 C 6 atm 10 C 6 atm 10 C 3.4 atm -5.6 C 3.4 atm -5.6 C S-5021 3.4 atm -5.6 C 6 atm 35.6 C 6 atm 13.3 C C-501 Primary Compressor 8292 kW C-502 Compressor 2 6432 kW C-503 Compressor 3 234.5 kW E-501 Condensor 144 GJ/hr E-502 Interstage Cooler 1785 m2 11.4 GJ/hr E-503 Precooler 1011 m2 33.6 GJ/hr V-501 Primary Knockout Drum 1.2 m-D x 6.7 m-H V-502 Secondary Knockout Drum 0.6 m-D x 6.7 m-H E-303b E-408 E-409b E-410b E-303a E-407 E-409a E-410a S-5025 6 atm 10 C 6 atm 10 C E-303a 9.5 GJ/hr E-407 68.8 GJ/hr E-409a 7.9 GJ/hr E-409b 3.9 GJ/hr E-408 27.4 GJ/hr E-410a 7.9 GJ/hr E-303b 3.8 GJ/hr E-410b 4.0 GJ/hr 437 kg-mol/hr 3162 kg-mol/hr 370 kg-mol/hr 370 kg-mol/hr 1835 kg-mol/hr 6169 kg-mol/hr 8900 kg-mol/hr 2731 kg-mol/hr 108 kg-mol/hr 1727 kg-mol/hr 168 kg-mol/hr 176 kg-mol/hr 174 kg-mol/hr 1209 kg-mol/hr 1727 kg-mol/hr AMMONIA PROCESSING PLANT REFRIGERATION SYSTEM PROCESS FLOW DIAGRAM SECTION 5 - UTILITIES APPROVED BY: CRYSTAL LIN, PM PLANT LOCATION – REPUBLIC OF TATARSTAN, RUSSIA MY CHEMICAL ROMANCE SOLUTION INC. LOS ANGELES, CALIFORNIA SCALE PROJECT NUMBER DRAWING NUMBER REV NONE 01-2012 108A-PANG-108B 5 DATE 06-06-2012 CLIENT – HP CHEMICAL SHEET 1 OF 3

Refrigerant PFD final

Embed Size (px)

DESCRIPTION

 

Citation preview

E-501

V-501

V-502

C-502 C-501

C-503

E-502 E-503

S-5001

S-5002 S-5003 S-5004 S-5005

S-5006

S-5007

S-5008

S-5009

S-5010

S-5011

S-5012

S-5013

S-5015

S-5016

TIC

I-1

Cold Water

Used Cold Water

17 atm93.3 C

17 atm65.5 C

41 atm166 C

41 atm87.8 C

40 atm78.8 C

6 atm10 C

6 atm10 C

3.4 atm-5.6 C

3.4 atm-5.6 C

S-5021

3.4 atm -5.6 C

6 atm35.6 C

6 atm13.3 C

C-501Primary Compressor

8292 kW

C-502Compressor 2

6432 kW

C-503Compressor 3

234.5 kW

E-501Condensor144 GJ/hr

E-502Interstage Cooler

1785 m211.4 GJ/hr

E-503Precooler1011 m2

33.6 GJ/hr

V-501Primary Knockout Drum

1.2 m-D x 6.7 m-H

V-502Secondary Knockout Drum

0.6 m-D x 6.7 m-H

E-303b

E-408

E-409b

E-410b

E-303a

E-407

E-409a

E-410a

S-5025

6 atm10 C

6 atm10 C

E-303a9.5 GJ/hr

E-40768.8 GJ/hr

E-409a7.9 GJ/hr

E-409b3.9 GJ/hr

E-40827.4 GJ/hr

E-410a7.9 GJ/hr

E-303b3.8 GJ/hr

E-410b4.0 GJ/hr

437 kg-mol/hr

3162 kg-mol/hr

370 kg-mol/hr

370 kg-mol/hr

1835 kg-mol/hr

6169 kg-mol/hr

8900 kg-mol/hr

2731 kg-mol/hr

108 kg-mol/hr

1727 kg-mol/hr

168 kg-mol/hr

176 kg-mol/hr

174 kg-mol/hr

1209 kg-mol/hr

1727 kg-mol/hr

AMMONIA PROCESSING PLANT

REFRIGERATION SYSTEM

PROCESS FLOW DIAGRAM

SECTION 5 - UTILITIES

APPROVED BY: CRYSTAL LIN, PM

PLANT LOCATION – REPUBLIC OF TATARSTAN, RUSSIA

MY CHEMICAL ROMANCE SOLUTION INC.

LOS ANGELES, CALIFORNIA

SCALE PROJECT NUMBER DRAWING NUMBER REV

NONE 01-2012 108A-PANG-108B 5

DATE 06-06-2012 CLIENT – HP CHEMICAL SHEET 1 OF 3