Upload
crystal-lin
View
212
Download
0
Embed Size (px)
DESCRIPTION
Â
Citation preview
E-501
V-501
V-502
C-502 C-501
C-503
E-502 E-503
S-5001
S-5002 S-5003 S-5004 S-5005
S-5006
S-5007
S-5008
S-5009
S-5010
S-5011
S-5012
S-5013
S-5015
S-5016
TIC
I-1
Cold Water
Used Cold Water
17 atm93.3 C
17 atm65.5 C
41 atm166 C
41 atm87.8 C
40 atm78.8 C
6 atm10 C
6 atm10 C
3.4 atm-5.6 C
3.4 atm-5.6 C
S-5021
3.4 atm -5.6 C
6 atm35.6 C
6 atm13.3 C
C-501Primary Compressor
8292 kW
C-502Compressor 2
6432 kW
C-503Compressor 3
234.5 kW
E-501Condensor144 GJ/hr
E-502Interstage Cooler
1785 m211.4 GJ/hr
E-503Precooler1011 m2
33.6 GJ/hr
V-501Primary Knockout Drum
1.2 m-D x 6.7 m-H
V-502Secondary Knockout Drum
0.6 m-D x 6.7 m-H
E-303b
E-408
E-409b
E-410b
E-303a
E-407
E-409a
E-410a
S-5025
6 atm10 C
6 atm10 C
E-303a9.5 GJ/hr
E-40768.8 GJ/hr
E-409a7.9 GJ/hr
E-409b3.9 GJ/hr
E-40827.4 GJ/hr
E-410a7.9 GJ/hr
E-303b3.8 GJ/hr
E-410b4.0 GJ/hr
437 kg-mol/hr
3162 kg-mol/hr
370 kg-mol/hr
370 kg-mol/hr
1835 kg-mol/hr
6169 kg-mol/hr
8900 kg-mol/hr
2731 kg-mol/hr
108 kg-mol/hr
1727 kg-mol/hr
168 kg-mol/hr
176 kg-mol/hr
174 kg-mol/hr
1209 kg-mol/hr
1727 kg-mol/hr
AMMONIA PROCESSING PLANT
REFRIGERATION SYSTEM
PROCESS FLOW DIAGRAM
SECTION 5 - UTILITIES
APPROVED BY: CRYSTAL LIN, PM
PLANT LOCATION – REPUBLIC OF TATARSTAN, RUSSIA
MY CHEMICAL ROMANCE SOLUTION INC.
LOS ANGELES, CALIFORNIA
SCALE PROJECT NUMBER DRAWING NUMBER REV
NONE 01-2012 108A-PANG-108B 5
DATE 06-06-2012 CLIENT – HP CHEMICAL SHEET 1 OF 3