SPECIFICATIONS
RX10LFT-ISFlush Mount Lift Rack
Site Specifications
Substructure Requirements Refer to 6199-T for full details
Power Requirements 208-230 VAC, single phase power, 26 Amp
Air Supply Requirements 90-150 PSI (6.2-10.3 bar)Jacks require 125 PSI (8.6 bar) for full capacity
Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700 kPA) ratingMaximum Floor Slope 2 in. (51mm) over 126 in. (3200 mm)
Product SpecificationsMax. Vehicle Weight 10,000 lbs. (4536 kg)
Max. Wheelbase General Service 180 in. (4572 mm) Two-Wheel Alignment 175 in. (4445 mm) Four-Wheel Alignment 158 in. (4013 mm)Alignment Height All lock positionsMin. Four-Wheel Alignment 88 in. (2235 mm)Lifting Speed 55 secondsLowering Speed 25 seconds
Form 6497-T, 06-15Supersedes Form 6497-T, 12-12a
Copyright © 2015, Hunter Engineering Company
For lift rack information visit:www.hunter.com/lift-racks
For local contact visit:www.hunter.com/contact-hunter
For general inquiries visit:www.hunter.com
or call800-448-6848
MODEL FEATURES / DIMENSIONS
Feature FT-IS
6000-lb Swing Air Jacks (2)
Two-Speed Lowering
Continued on Page 2
RX10LFT-IS Shown
W1
H1
H2
L
Dimension
Outside Width (W1) 88.5 in.2248 mm
Inside Width (W2) 40 in.1016 mm
Length (L) 228.375 in.5801 mm
Runway Width (R) 24 in. 610 mm
Raised Height (H1) 72 in1829 mm
Depth (H2) 9.25 to 10.25 in.235 mm to 260 mm
W2 R
SPECIFICATIONS (Refer to 6199-T for substructure construction requirements)
RX10LFT-ISFlush Mount Lift Rack
Form 6497-T, 06-15Supersedes Form 6497-T, 12-12a
Copyright © 2015, Hunter Engineering Company
Dimensions shown are for finished pits. Tile thickness (if applicable) must be considered before pouring pit.
*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet (1829 mm) at the approach ramp end and 18 feet (5486 mm) at the turnplate end. Additional threshold and perhaps hydraulic hoses will be required (refer to Installation Instruction for details).
! WARNING
!WARNING
!WARNING
!WARNING
DRAINLOCATED
INCENTEROF PIT
SLOPEPIT
FLOORTOWARD
DRAIN(1/2")
CONSOLE CONDUIT DETAIL
92 1/2"(2350 mm)
! WARNINGSTAY BEHINDYELLOW LINE
WHEN THELIFT MOVES.
128-978-2
DECAL 128-978-2
OPTIONAL CONSOLE LOCATION
(4 places on edging and 2 places on lift)
41 3/8"(1051 mm)
141 3/4"(3600 mm)
14"(356 mm)
APPROX. 2"(51 mm) TYPICAL
14"(356 mm)
5"(127 mm)
5"(127 mm)
14" X 5"CUTOUT(4 places)
ANGLE AROUND PIT PERIMETER:- not around
- painted safety yellow- not supplied by Hunter
14" X 5"cutouts
16"(406mm)
22"(559 mm)
6" MIN.*152 mm( )
OPTIONAL 1 1/2" DIA. CONDUITFOR COMMUNICATION CABLE
TO ALIGNMENT CONSOLE
HAWKEYE SERIES SENSORSAND PRONTO SYSTEMS HAVE
SPACE REQUIREMENTS INFRONT OF LIFT THAT MUST BEMET, REFER TO APPROPRIATE
SITE REQUIREMENTS.
ENTIRE PIT(BOTTOM AND WALLS)
MUST BE HARDTROWEL FINISH
FILLER PLATE51-2308-1(4 places)
(placed over14" X 5"cutout)
34 3/4"(883 mm) EXTENDER
PLATES51-2464-1-PPP
ANDRAMPS
147-141-1-PPP
RAMPS147-141-1-PPP
66 3/4"(1695 mm)
228 3/8"(5801 mm)
30 3/4"(781 mm)
BAY DOOR BAY DOOR
45
6" MIN.RADIUS CONDUIT
EXIT FLUSHWITH
PIT FLOOR
ROUTE 4" MIN DIAMETERCONDUIT OR EQUIVALENTCLOSED CHANNEL FROMPIT FLOOR TO BASE OF
CONSOLE
VEHICLE APPROACH
* LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TOACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO ( ) ORGREATER.
39" 991 mm** SITES WITH D.R.W. TRUCKTRAFFIC SHOULD USE 20" MIN.CONSOLE TO PIT DISTANCE.
**15" TO 41"
(381 TO 1041 mm)