• Electrical Engineer• 10 years with Altech Corporation• Product Manager of Circuit Breakers,
Busbars, Motor Disconnect Switches,Foot Switches, Sensors, Contactors,Motor Starters, Pin & Sleeve Connectors
Klaus Tum (short bio)
•Miniature circuit breakers• UL 508 • UL 1077 (NEW)• UL 489 (NEW)• UL 489 MCCB (NEW)
•Three phase adjustable trip circuit breakers•Earth leakage circuit breakers•Accessories
Altech Line of Circuit Breakers
UL 1077 R Series
• DIN Rail mounted, 17.5mm width per pole
• Thermal Magnetic
• 480Y/277 VAC, 50/60Hz
• Short Circuit Withstand Capacity 10kA
• Positive Trip indicator(Green – Off/Tripped, Red – On)
• 0.5 – 63 Amp
Trip Curves
• B, C, D curves for branch circuit protection of sensitive electronics, power supplies, appliance circuits, etc.
Extremely Competitive!
Altech 1077 R Series Automation Direct
1 Pole $8.80 $8.50
2 Pole $17.60 $17.00
3 Pole $26.40 $24.00
All Altech Prices are List Prices.Standard Partner Distributor discount is 25%!
Quantity discounts, special pricing available.
TR11 Series
• UL 1077 recognized
• 0.5 – 16 Amps
• Thermal circuit breaker
• 240 VAC, 50/60 Hz , 32 VDC
Trip Curve
• Used in protection of single phase Motors, Transformers, UPS, Power strips, Solenoids, etc.
UL 489 Series
• Altech 489 series is UL listed as a branch circuit breaker and can protect a branch circuit without any backup fuse
• Altech 489 series is suitable for field wiring
• Breaker features a trip indicator window. Helps in quick identification and fault finding.
UL 489 Series Accessories
• Shunt Trips to enable remote shutdown of breaker
• Lockoff adapters to prevent accidental actuation
• Auxiliary Contacts and Neutral Poles.
Why Altech UL 489 Series?
Best Ratings in the Industry!!!!
Altech UL 489 Series0.2 – 63 Amps / 240 VAC0.2 – 32 Amps / 480 Y / 277 VAC
Square D / Merlin Gerin1 – 35 Amps / 240 VAC
ABB0.2 – 63 Amps / 240 VAC0.2 – 25 Amps / 480 Y / 277 VAC
Allen Bradley0.5 – 40 Amps / 240 VAC0.5 – 20 Amps / 480 Y / 277 VAC
UL 489 Molded Case Circuit Breakers
• UL 489 Listed
• Compact Space Saving Design. Only 3 different frame sizes
• Upto 100kA Interrupting Capacity
Sizes
Part# Width Height Depth
100AF 4.13 7.28 3.39
225AF (105) (185) (86)
400AF 5.51 11.02 4.33
(140) (280) (110)
600AF 8.27 11.02 4.33