Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 2
Securing your mission-critical networksNetwork security is not optional. When a reliable and secure network is table stakes, you need a solution that delivers top-notch network security as well as more efficiency, speed, and convenience in identifying networks. Our secure solutions allow for a completely customizable installation, from the data center throughout the local area network.
With 12 colored keys available, you can simply and quickly segment the network and prevent inadvertent connection into the wrong network. Our keyed and colored, and Non-keyed colored options are available for both preterminated and field-terminated in LAN and DC applications.
When network security is critical, you can rely on the company that invented low-loss optical fiber and has continued to innovate to solve tough technology challenges.
Security For Your Networks
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 3
OfferingsPRETERMINATED SOLUTIONS FIELD-TERMINATED SOLUTIONS
MTP Keyed Connectors
Keyed-to- Keyed Adapters
EDGE8™ Keyed MTP®
Non-Keyed- to- Non-Keyed Adapters
MTP Non-Keyed Connectors
Keyed-to- Non-Keyed Adapters
EDGE8 Non-KeyedMTP
Unicam® Keyed Connectors
LC Keyed Connectors
LC Non-Keyed Connectors
MTPKeyed Adapters
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Color Options:
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 4
EDGE8 Solutions- Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40- Port Breakout Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41- MTP Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42- MTP Extender Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43- MTP Hybrid Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44- MTP Hybrid Extender Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . .45- Harness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46- MTP Jumpers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47- MTP Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48- LC Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
EDGE Solutions- Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50- Plug & Play Systems Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51- Plug & Play Systems Extender Trunks. . . . . . . . . . . . . . . . . . .52- Plug & Play Systems LC to LC Trunks . . . . . . . . . . . . . . . . . . . .53- Plug & Play Systems Hybrid Trunks . . . . . . . . . . . . . . . . . . . . .54- Plug & Play Systems Hybrid Extender Trunks . . . . . . . . . . .55- Plug & Play Systems Trunk Harnesses . . . . . . . . . . . . . . . . . .56- Plug & Play Systems Module Harnesses . . . . . . . . . . . . . . . .57- Plug & Play Systems CCH Modules . . . . . . . . . . . . . . . . . . . . .58- Plug & Play Systems Integrated Trunk Modules . . . . . . . .59- MTP Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60- Plug & Play Systems Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . 61- Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
- Hardware Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74- Hardware Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75- Hardware Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76- Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
ContentsPRETERMINATED KEYED SOLUTIONS PRETERMINATED NON-KEYED SOLUTIONS ADDITIONAL PRODUCTS AND RESOURCES
FIELD-TERMINATED KEYED SOLUTIONS FIELD-TERMINATED NON-KEYED SOLUTIONS- Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30- Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31- Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32- CCH Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33- CCH Pigtailed Modules and - Panels . . . . . . . . . . . . . . . . . . . 34- CCH Pigtailed Splice Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . .35- Wall-Plate Outlets (WLL) Single-Gang . . . . . . . . . . . . . . . . . 36- Workstation Multimedia Outlets (WMO) . . . . . . . . . . . . . .37- Fiber-to-the-Desk Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
- Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64- Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65- Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66- CCH Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67- CCH Pigtailed Modules and Panels . . . . . . . . . . . . . . . . . . . . 68- CCH Pigtailed Splice Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . 69- Wall-Plate Outlets (WLL) Single-Gang . . . . . . . . . . . . . . . . . .70- Workstation Multimedia Outlets (WMO) . . . . . . . . . . . . . . 71- Fiber-to-the-Desk Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
EDGE8™ Solutions- Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6- Port Breakout Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- MTP® Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8- MTP Extender Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9- MTP Hybrid Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10- MTP Hybrid Extender Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11- Harness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12- MTP Jumpers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13- Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14- LC Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
EDGE™ Solutions- Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16- Plug & Play™ Systems Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17- Plug & Play Systems Extender Trunks. . . . . . . . . . . . . . . . . . . 18- Plug & Play Systems LC to LC Trunks . . . . . . . . . . . . . . . . . . . .19- Plug & Play Systems Hybrid Trunks . . . . . . . . . . . . . . . . . . . . 20- Plug & Play Systems Hybrid Extender Trunks . . . . . . . . . . . 21- Plug & Play Systems Trunk Harnesses . . . . . . . . . . . . . . . . . .22- Plug & Play Systems Module Harnesses . . . . . . . . . . . . . . . .23- Plug & Play System CCH Modules . . . . . . . . . . . . . . . . . . . . . .24- Plug & Play Systems Integrated Trunk Modules . . . . . . . .25- MTP Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26- Plug & Play Systems Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . .27- Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 5
Preterminated Keyed Solutions
Preterminated Keyed Solutions
Our EDGE8™ and EDGE™ solutions have become an integral part of the secure environment. Providing the user 12 color-coded key options, the keyed MTP® and LC solutions provide added flexibility and easy network identification. Customizable for efficiency, the keys offer decreased margins of error. The keyed connectors, located on the front and back of the patch panel, are used to match access rights to the proper network. Most importantly, the keys cannot be duplicated with standard components, making this one of the most risk-averse product solutions on the market.
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 6
Preterminated Keyed SolutionsEDGE8™ Solutions | Modules
Select wiring/polarity.U = Universal R = Straight-through
Defines fiber count.08 = 8-fiber
Select front connector.26 = LC multimode 33 = LC single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select back connector.K6 = MTP® 8-fiber (non-pinned)
multimodeK8 = MTPA 8-fiber (non-pinned)
single-mode
Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber type.G = Single-mode Ultra (OS2) Q = 50 μm multimode (OM4)
1 4 6
2
573
ECM8 - M 08 - - - ULL1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 7
Preterminated Keyed SolutionsEDGE8™ Solutions | Port Breakout Modules
Select front connector.26 = LC duplex, multimode 33 = LC duplex, single-mode Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select keyed MTP®.K6 = MTP (non-pinned),
multimodeK8 = MTPA (non-pinned),
single-mode
Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber type.Q = 50 μm multimode (OM4) G = Single-mode Ultra
Select cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select module type.A = Type A B = Type B
Select the cable length.(Lengths are measured from furcation plug to furcation plug) 003-075 ft(1-ft increments measured from MTP to back of module) 001-025 m(1-m increments measured from MTP to back of module)
Select unit of measure.F = Feet M = Meter
1 4
6
2
5
8
10
7
9
3
ECM8 - - 1 2 4 5 6 7 8 103 9
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 8
Preterminated Keyed SolutionsEDGE8™ Solutions | MTP® Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector.Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
KeyedK5 = MTP 8-fiber (pinned),
multimodeK7 = MTPA 8-fiber (pinned),
single-mode
Select the MTP connector.Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
KeyedK5 = MTP (pinned), multimodeK7 = MTPA (pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure. F = Feet M = Meters
Defines suffix. S = Secure
Select end 1 leg length.D = 33-in legs Note – Furcation legs are color coded by fiber type
Select end 2 leg length.D = 33-in legs Note – Furcation legs are color coded by fiber type
Select wiring/polarity.U = Universal P = Straight-through
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
1 4 9 13
14
10
11
12
6
2
5
7
8
3
S2 31 4 6 7 8 9 10 11 13 145 12
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 9
Select unit of measure. F = Feet M = Meters
Defines suffix. S = Secure
13
14
Preterminated Keyed SolutionsEDGE8™ Solutions | MTP® Extender Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector (end 1).Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
Keyed K5 = MTP (pinned), multimodeK7 = MTPA (pinned), single-mode
Select the MTP connector (end 2).Non-keyed E6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Keyed K6 = MTP (non-pinned),
multimodeK8 = MTPA (non-pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.D = 33-in legs (-0/+3 in)
Select end 2 leg length.C = 60-in legs (-0/+3 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.X = Extender trunk (straight-through polarity)
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
1 4 9
10
11
126
2
5
7
8
3
X S2 31 4 6 7 8 9 10 11 13 145 12
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 10
8
Preterminated Keyed SolutionsEDGE8™ Solutions | MTP® Hybrid Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector (end 1).Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
KeyedK5 = MTP (pinned), multimodeK7 = MTPA (pinned), single-mode
Select the LC connector (end 2).Non-keyed 79 = LC uniboot, multimode 78 = LC uniboot, single-mode
Keyed 26 = LC uniboot, multimode 33 = LC uniboot, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *Keyed connector pairings exclude black and white
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure. F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.D = 33-in legs (-0/+3 in) Note – Furcation legs are color coded by fiber type
Select end 2 leg length.J = 12-in (+3/-0 in) K = 24-in (+3/-0 in) L = 36-in (+3/-0 in) M = 48-in (+3/-0 in) N = 60-in (+3/-0 in) P = 72-in (+3/-0 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.W = Universal hybrid
1 4
9
13
10
11
12
6
2
5
7
3
W S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 11
8
Preterminated Keyed SolutionsEDGE8™ Solutions | MTP® Hybrid Extender Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector (end 1).Non-keyedE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Keyed K6 = MTP (non-pinned), multimodeK8 = MTPA (non-pinned),
single-mode
Select the LC connector (end 2).Non-keyed 79 = LC uniboot, low-loss
multimode78 = LC uniboot, single-mode
Keyed 26 = LC uniboot, multimode 33 = LC uniboot, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *Keyed connector pairings exclude black and white
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.C = 60-in legs Note – Furcation legs are color coded by fiber type
Select end 2 leg length.J = 12-in (+3/-0 in) K = 24-in (+3/-0 in) L = 36-in (+3/-0 in) M = 48-in (+3/-0 in) N = 60-in (+3/-0 in) P = 72-in (+3/-0 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.Z = Hybrid extender (straight-through polarity)
1 4
9
13
10
11
12
6
2
5
7
3
Z S2 31 4 6 7 8 9 10 11 13 145 12
14
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 12
3
Preterminated Keyed SolutionsEDGE8™ Solutions | Harness
Select the MTP® connector.Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-modeE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Keyed K5 = MTP (pinned), multimodeK6 = MTP (non-pinned),
multimodeK7 = MTPA (pinned), single-modeK8 = MTPA (non-pinned),
single-mode
Select the LC connector. Non-keyed 79 = LC uniboot, multimode 78 = LC uniboot, single-mode
Keyed 26 = LC uniboot, multimode 33 = LC uniboot, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Defines fiber count.08 = 8-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select leg length.J = 12-in (+3/-0 in) K = 24-in (+3/-0 in) L = 36-in (+3/-0 in) M = 48-in (+3/-0 in) N = 60-in (+3/-0 in) P = 72-in (+3/-0 in) Note – Furcation legs are color coded by fiber type
Select wiring/polarity.A = Type-A polarity B = Type-B polarity
Select the cable length.003-200 ft(1-ft increments measured from MTP to furcation plug and does not include stagger) 001-060 m(1-m increments measured from MTP to furcation plug and does not include stagger) Note – Longer lengths available upon request
1
4
9
10
11
6
2
5
7
8
H 08 - S 1 2 4 5 6 7 8 11103 9 12
12
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 13
Preterminated Keyed SolutionsEDGE8™ Solutions | MTP® Jumpers
Select the MTP connector. Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-modeE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
KeyedK5 = MTP (pinned), multimodeK6 = MTP (non-pinned),
multimodeK7 = MTPA (pinned), single-modeK8 = MTPA (non-pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *Keyed connector pairings exclude black and white
Select the overall jumper length.003-200 ft(1-ft increments measured from MTP to furcation plug and does not include stagger) 001-060 m(1-m increments measured from MTP to furcation plug and does not include stagger)
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Defines fiber count.08 = 8-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua Defines furcation length.N = No furcation
Select wiring/polarity.A = TIA-568 Type-A
(straight-through)B = TIA-568 Type-B (MTP flip)
1 4
9
10
11
6
2
5
7
83
J 08 E - N S 1 2 4 5 6 7 8 11103 9 12
Select the MTP® connector.Non-keyedE5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-modeE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Keyed K5 = MTP (pinned), multimodeK6 = MTP (non-pinned),
multimodeK7 = MTPA (pinned), single-modeK8 = MTPA (non-pinned),
single-mode
12
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 14
Preterminated Keyed SolutionsEDGE8™ Solutions | Panels
Select fiber count.08 = 8-fiber16 = 16-fiber32 = 32-fiber
Select adapter color.N1 = GreenN2 = RedN3 = YellowN4 = BlueN5 = OrangeN6 = RoseN7 = SlateN9 = VioletNA = AquaNB = Brown
1 2
EDGE8 - CP - 1 2
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 15
Preterminated Keyed SolutionsEDGE8™ Solutions | LC Panels
Select adapter color.AP = SlateAT = RoseAK = GreenAS = WhiteAL = VioletAG = BlueAH = RedAM = OrangeAQ = BrownAR = AquaAJ = YellowAN = Black
1
EMOD8 - CP 08 - 1
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 16
Preterminated Keyed SolutionsEDGE™ Solutions | Modules
Select wiring/polarity.U = Universal R = Classic
Defines fiber count.12 = 12-fiber
Select front connector.26 = LC, multimode 33 = LC, single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select back connector.Y2 = MTP, low-loss (pinned),
multimodeY4 = MTP, standard loss
(pinned), single-mode
Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber type.G = Bend-improved single-mode
Ultra (OS2) T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4)
1 4 6
2
573
ECM - M 12 - - 1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 17
3
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.Non-keyed 75 = MTP®, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Keyed Y1 = MTP, low-loss (non-pinned),
multimodeY3 = MTP, standard loss
(non-pinned), single-modeY5 = MTP, low-loss elite
(non-pinned), single-mode No Connector 00 = Pigtail (available on ribbon
interconnect)
Select end 2 leg length.A = 24-in minimum stagger (-0/+3 in)B = 36-in minimum stagger (-0/+3 in) Note – Furcation legs are color coded by fiber type
Select wiring/polarity.U = Universal C = Classic P = Straight-through
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cableC = Ribbon plenum*R = Ribbon interconnect
(12-fiber only)**Available in pigtails only
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in)0 = Pigtail Note – Furcation legs are color coded by fiber type
1
4
9 13
10
12
6
2
5
7
S2 31 4 6 7 8 9 10 11 13 145 12
11
8
14
Select end 2 connector.Non-keyed 75 = MTP, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Keyed Y1 = MTP, low-loss
(non-pinned), multimodeY3 = MTP, standard loss
(non-pinned), single-modeY5 = MTP, low-loss elite
(non-pinned), single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 18
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Extender Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.Non-keyed 93 = MTP®, low-loss
(pinned), multimode89 = MTP, standard loss
(pinned), single-mode
Keyed Y2 = MTP, low-loss
(pinned), multimodeY4 = MTP, standard loss
(pinned), single-modeY6 = MTP, low-loss elite
(pinned), single-mode
Select end 2 connector.Non-keyed 75 = MTP, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Keyed Y1 = MTP, low-loss
(non-pinned), multimodeY3 = MTP, standard loss
(non-pinned), single-modeY5 = MTP, low-loss elite
(non-pinned), single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *MTP keyed connector pairings exclude black and white
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Select end 2 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.X = Extender trunk Note – Straight-through polarity
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cable
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
1
4
9
13
10
12
6
2
5
7
3
11
8
X S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 19
4
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems LC to LC Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector. Non-keyed 04 = LC duplex, single-mode 05 = LC duplex, multimode Keyed 26 = LC, multimode 33 = LC, single-mode No Connector 00 = Pigtail (available on
ribbon interconnect)
Select end 2 connector.Non-keyed 04 = LC duplex, single-mode 05 = LC duplex, multimode Keyed 26 = LC, multimode 33 = LC, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *MTP keyed connector pairings exclude black and white
Select fiber count.06 = 6-fiber 48 = 48-fiber 12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select end 2 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.C = Classic trunk
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cableC = Ribbon plenum*R = MIC 250 cable
(6- and 12-fiber only) Note – Furcation legs are color coded
Select jacket color.N = Blue E = Orange G = Green K = Brown S = Slate W = White R = Red B = Black Y = Yellow V = Violet P = Rose A = Aqua
Select end 1 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mmO = Pigtail Note – Furcation legs are color coded by fiber type
1
5
9
13
10
12
6
2
7
3
118
C S2 31 4 6 7 8 9 10 11 13 145 12
14
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 20
10
11
7
8
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Hybrid Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.Non-keyed 75 = MTP®, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Keyed Y1 = MTP, low-loss
(non-pinned), multimodeY3 = MTP, standard loss
(non-pinned), single-modeY5 = MTP, low-loss elite
(non-pinned), single-mode
Select end 2 connector.Non-keyed 04 = LC duplex, single-mode 05 = LC duplex, multimode Keyed 26 = LC, multimode 33 = LC, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *MTP keyed connector pairings exclude black and white
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cable
Defines wiring/polarity.W = Universal hybrid
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
Select end 2 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
1 4
9
13
12
6
2
5
3
W S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 21
14
8
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Hybrid Extender Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.Non-keyed 93 = MTP®, low-loss
(pinned), multimode89 = MTP, standard loss
(pinned), single-mode
Keyed Y2 = MTP, low-loss
(pinned), multimodeY4 = MTP, standard loss
(pinned), single-modeY6 = MTP, low-loss elite
(pinned), single-mode
Select end 2 connector.Non-keyed 04 = LC duplex, single-mode 05 = LC duplex, multimode Keyed 26 = LC, multimode 33 = LC, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cable
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
Select end 2 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.Z = Hybrid extender (straight-through polarity)
1 4
9
13
10
12
6
2
5
73
11
Z S2 31 4 6 7 8 9 10 11 13 145 12
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 22
12
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Trunk Harnesses
Select end 1 connector.Non-keyed 93 = MTP®, low-loss
(pinned), multimode89 = MTP, standard loss
(pinned), single-mode
Keyed Y2 = MTP, low-loss
(pinned), multimodeY4 = MTP, standard loss
(pinned), single-modeY6 = MTP, low-loss elite
(pinned), single-mode
Select end 2 connector.Non-keyed 04 = LC duplex, single-mode05 = LC duplex, multimode79 = LC duplex uniboot,
multimode78 = LC duplex, uniboot,
single-mode
Keyed 26 = LC, multimode 33 = LC, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *MTP keyed connector pairings exclude black and white
Defines fiber count.12 = 12-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Defines cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.Z = Trunk harness *Universal polarity(Blue to the right)
Select the harness length.003-200 ft(1-ft increments measured from plugto MTP and does not include stagger) 001-060 m(1-m increments measured from plug to MTP and does not include stagger)
1
9
10
6
25
3 11
7
8
H 12 E - Z S 1 2 4 5 6 7 8 11103 9 12
4
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 23
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Module Harnesses
Select end 1 connector.Non-keyed 75 = MTP®, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Keyed Y1 = MTP, low-loss
(non-pinned), multimodeY3 = MTP, standard loss
(non-pinned), single-modeY5 = MTP, low-loss elite
(non-pinned), single-mode
Select end 2 connector.Non-keyed 04 = LC duplex, single-mode05 = LC duplex, multimode79 = LC duplex uniboot,
multimode78 = LC duplex, uniboot,
single-mode
Keyed 26 = LC, multimode 33 = LC, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black* G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White* A = Aqua *MTP keyed connector pairings exclude black and white
Defines fiber count.12 = 12-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Defines cable type.E = Plenum interconnect
Select the harness length.003-200 ft(1-ft increments measured from plugto MTP and does not include stagger) 001-060 m(1-m increments measured from plug to MTP and does not include stagger)
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.W = Module harness(Aqua to the right)
1
9
10
6
25
3
11
7
8
H 12 E - W S 1 2 4 5 6 7 8 11103 9 12
4
12
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 24
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ System CCH Modules
Select wiring/polarity.U = Universal R = Classic
Select fiber count.12 = 12-fiber 24 = 24-fiber
Select front connector.26 = LC, multimode 33 = LC, single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select back connector.Y2 = MTP, low-loss
(pinned), multimodeY4 = MTP, standard loss
(pinned), single-mode
Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
1 4 6
2
57
3
CCH - M - - 1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 25
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Integrated Trunk Modules
Defines wiring/polarity.U = Universal
Select front connector.26 = LC, multimode 33 = LC, single-mode
Select back connector.Y2 = MTP, low-loss
(pinned), multimodeY4 = MTP, standard loss
(pinned), single-modeY1 = MTP, low-loss
(non-pinned), multimodeY3 = MTP, standard loss
(non-pinned), single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select jacket color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select the cable length.040 = 40-ft080 = 80-ft120 = 120-ft160 = 160-ft200 = 200-ft
1 4 6
2
573
ITM U - 12 - - - - F1 2 4 6 73 5
Preterminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 26
Preterminated Keyed SolutionsEDGE™ Solutions | MTP® Panels
Select fiber count.12 = One MTP® adapter24 = Two MTP adapters36 = Three MTP adapters48 = Four MTP adapters
Select adapter color.N1 = GreenN2 = RedN3 = YellowN4 = BlueN5 = OrangeN6 = RoseN7 = SlateN9 = VioletNA = AquaNB = Brown
1 2
EDGE - CP - 1 2
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 27
2
3
Preterminated Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Jumpers
Select end 1 MTP® connector.Non-keyed 75 = MTP, low-loss
(non-pinned), multimode89 = MTP, low-loss
(pinned), single-mode90 = MTP, standard loss
(non-pinned), single-mode93 = MTP, low-loss
(pinned), multimode
Keyed Y1 = MTP, low-loss
(non-pinned), multimodeY3 = MTP, standard loss
(non-pinned), single-modeY5 = MTP, low-loss elite
(non-pinned), single-modeY2 = MTP, low-loss
(pinned), multimodeY4 = MTP, standard loss
(pinned), single-modeY6 = MTP, low-loss elite
(pinned), single-mode
Select end 2 MTP connector. See options listed to the left.
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Defines fiber count.12 = 12-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Defines cable type.E = Plenum interconnect
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines furcation length.(Could be used for 100G furcation leg lengths)N = No furcation for 40G jumper
Select wiring/polarity.A = TIA-568 Type-A array jumper
(straight-through)B = TIA-568 Type-B array jumper
(MTP flip)C = TIA-568 Type-C array jumper
(pairwise flip)
Select jumper length.1–999
1
4
9
10
11
6
5
7
8
J 12 E - N S 1 2 4 5 6 7 8 11103 9 12
Preterminated Keyed Solutions
12
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 28
Preterminated Keyed SolutionsEDGE™ Solutions | Cable Assemblies
Select end 1 connector.00 = No connectors (pigtail) Multimode03 = LC PC simplex 05 = LC PC duplex
24 = Keyed LC PC simplex 26 = Keyed LC PC duplex27 = Secure LC PC duplex Single-mode02 = LC UPC simplex 04 = LC UPC duplex
30 = Keyed LC UPC simplex 33 = Keyed LC UPC duplex91 = Secure LC UPC duplex Always use the lowest code first when constructing part numbers
Select end 2 connector.See options above
Select fiber count.01 = 1-fiber02 = 2-fiber
Select fiber type.K = 62.5 μm multimode (OM1) T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode (OM1)
Select cable type.21 = Single-fiber riser 2.0 mm51 = Zipcord riser 2.0 mm28 = Single-fiber plenum 2.0 mm58 = Zipcord plenum 2.0 mm
Select connector 1 color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua Z = Non-keyed LC
Select connector 2 color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua Z = Non-keyed LC
Select assembly length.002-250(For lengths greater than 999, contact Corning customer care)
Select unit of measure.F = Feet M = Meter
Select cable color. Nonstandard colorsBL = Blue GR = Green SL = Slate RD = Red YL = Yellow BR = Brown OR = Orange BL = Black WH = White RS = Rose VI = Violet AQ= Aqua
Standard colorsSingle-mode (OS2) YL = YellowMultimode (OM1)OR = OrangeMultimode (OM3/OM4) AQ = Aqua
1 4
6
5
8
10
7
9
3
- 2 31 4 6 7 8 9 105
2
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 29
Field-Terminated Keyed Solutions
Field-Terminated Keyed Solutions
We offer network security for any organization looking to mitigate privacy or security concerns. Giving the user 12 color-coded key options, the keyed LC solution provides added flexibility and easy network identification. Customizable for efficiency, the keys offer decreased margins of error when identifying a network. The keyed connectors, located on the front and back of the patch panel, are used to match access rights to the proper network. Most importantly, the keys cannot be duplicated with standard components, making this one of the most risk-averse product solutions on the market.
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 30
Offered in 12 colors, our MIC® (indoor) and FREEDM® (indoor/outdoor) riser-rated cables allow the user to quickly identify different networks. These cables are also available with interlocking and all-dielectric armor for added physical protection and peace of mind.
The following colors are available:
Please contact Corning Customer Care for part numbers and lead times.
Email: [email protected]
Phone Number: 1-800-743-2675
Blue Red
Orange Black
Green Yellow
Brown Purple
Slate Rose
White Aqua
Field-Terminated Keyed SolutionsCables
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 31
Field-Terminated Keyed SolutionsConnectors
Select fiber type.000 = 62.5 μm multimode (OM1)050 = 50 μm multimode (OM2)05X = 50 μm multimode
(OM3/OM4/OM4+)200 = Single-mode (OS2)
Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green B = Black S = Slate V = Violet
1 2
95 - - K 1 2
Select fiber type.101 = 62.5 μm multimode (OM1)051 = 50 μm multimode (OM2)201 = Single-mode (OS2)
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
1 2
95 - - 98 - SP - K 1 2
UniCam® LC Keyed Connectors
Anaerobic LC Keyed Connectors
Field-Terminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 32
Field-Terminated Keyed SolutionsAdapters
Select adapter color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
1
Select adapter color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
1
ADP - KDLC - CC RF - CLS1
ADP - KDLC - CC RF - CLX1
Keyed-to-Keyed Adapters
Keyed-to-Non-Keyed Adapters
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 33
Select fiber count.06 = 6-fiber (three duplex adapters)08 = 8-fiber (four duplex adapters)12 = 12-fiber (six duplex adapters)16 = 16-fiber (eight duplex adapters)24 = 24-fiber (12 duplex adapters)
Select adapter color.K1 = Blue K5 = RedKH = Orange KK = BlackKD = Green K9 = YellowKN = Brown KM = VioletKL = Slate KQ = RoseKP = White KR = Aqua
1 2
Field-Terminated Keyed SolutionsCCH Panels
Select fiber count.06 = 6-fiber (three duplex adapters)08 = 8-fiber (four duplex adapters)12 = 12-fiber (six duplex adapters)16 = 16-fiber (eight duplex adapters)24 = 24-fiber (12 duplex adapters)
Select adapter color.LE = Blue LA = RedLH = Orange LF = BlackLB = Green LD = YellowLL = Brown LK = VioletLG = Slate LN = RoseLM = White LP = Aqua
1 2
1
CCH - CP - 1 2
CCH - CP - 1 2
Closet Connector Housing (CCH) Keyed-to-Non-Keyed Panels
Closet Connector Housing (CCH) Keyed-to-Keyed Panels
Field-Terminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 34
Field-Terminated Keyed SolutionsCloset Connector Housing (CCH) Pigtailed Modules and Panels
Select module or panel.RM = ModuleCP = Panel
Select fiber count.06 = 6-fiber08 = 8-fiber12 = 12-fiber16 = 16-fiber24 = 24-fiber
Select keyed LC duplex adapter style/color. Keyed on both front and back adapterK1 = Blue K5 = RedKH = Orange KK = BlackKD = Green K9 = YellowKN = Brown KM = VioletKL = Slate KQ = RoseKP = White KR = Aqua
Keyed on front of adapter only,non-keyed on backLE = Blue LA = RedLH = Orange LF = BlackLB = Green LD = YellowLL = Brown LK = VioletLG = Slate LN = RoseLM = White LP = Aqua
Select fiber type.K = 62.5 μm multimode (OM1)C = 50 μm multimode (OM2)S = 50 μm multimode (OM4)R = Single-mode (OS2)
Select cable type.H = MIC® cable subunit
(standard fiber cable option)J = Ribbon fiber
1
2
5
3
CCH - - - - P03 1 2 3 4 5
4
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 35
Field-Terminated Keyed SolutionsCloset Connector Housing (CCH) Pigtailed Splice Cassettes
Select fiber count.06 = 6-fiber08 = 8-fiber12 = 12-fiber16 = 16-fiber24 = 24-fiber
Select keyed LC duplex adapter style/color. Keyed on both front and back adapterK1 = Blue K5 = RedKH = Orange KK = BlackKD = Green K9 = YellowKN = Brown KM = VioletKL = Slate KQ = RoseKP = White KR = Aqua
Keyed on front of adapter only,non-keyed on backLE = Blue LA = RedLH = Orange LF = BlackLB = Green LD = YellowLL = Brown LK = VioletLG = Slate LN = RoseLM = White LP = Aqua
Select fiber type.K = 62.5 μm multimode (OM1)B = 50 μm multimode (OM2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)R = Single-mode (OS2)
Select splicing type.E = Single-fiber splicingJ = Ribbon splicing (only for
fiber counts of 12 or 24)
1
2
3
4
CCH - CS - - - P00 1 2 3 4
Field-Terminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 36
Field-Terminated Keyed SolutionsWall-Plate Outlets (WLL) Single-Gang
Select number of ports and orientation.A = 1, straight M = 1, angledB = 2, straight N = 2, angledC = 3, straight P = 4, angledD = 4, straightE = 6, straight
Select keyed LC duplex adapter style/color. Keyed on both front and back adapterK1 = Blue K5 = RedKH = Orange KK = BlackKD = Green K9 = YellowKN = Brown KM = VioletKL = Slate KQ = RoseKP = White KR = Aqua
Keyed on front of adapter only,non-keyed on backLE = Blue LA = RedLH = Orange LF = BlackLB = Green LD = YellowLL = Brown LK = VioletLG = Slate LN = RoseLM = White LP = Aqua
1 2
WLL A - 1
Port
2
1 2 3 4 5 6
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 37
3
Field-Terminated Keyed SolutionsWorkstation Multimedia Outlets (WMO)
Select number of fiber connections per panel.1 = 1-fiber connection2 = 2-fiber connections4 = 4-fiber connections
(SC duplex, LC duplex)
Select keyed LC duplex adapter style/color. Keyed on both front and back adapterK1 = Blue K5 = RedKH = Orange KK = BlackKD = Green K9 = YellowKN = Brown KM = VioletKL = Slate KQ = RoseKP = White KR = Aqua
Keyed on front of adapter only,non-keyed on backLE = Blue LA = RedLH = Orange LF = BlackLB = Green LD = YellowLL = Brown LK = VioletLG = Slate LN = RoseLM = White LP = Aqua
Select adapter color.35 = Beige85 = White
1 2
WMO - CP0 - - - 1 2 3
Field-Terminated Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 38
7
Field-Terminated Keyed SolutionsFiber-to-the-Desk Module
Select wiring/polarity.U = Universal R = Classic
Defines fiber count.12 = 12-fiber
Select front connector.26 = LC, multimode 33 = LC, single-mode
Select connector color.N = Blue R = Red E = Orange Y = Yellow G = Green V = Violet K = Brown P = Rose S = Slate A = Aqua
Select back connector.Y2 = MTP, low-loss (pinned),
multimodeY4 = MTP, standard loss
(pinned), single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = AquaZ = Non-keyed LC
Select fiber type.T = ClearCurve® (OM3) Q = ClearCurve (OM4) G = XB, single-mode
Select module type.J = Junction box F = Floor box
1
4
6
2
5
8
3
MAM - M - 12 - - - 1 82 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 39
Preterminated Non-Keyed Solutions
Preterminated Non-Keyed Solutions
Our EDGE8™ and EDGE™ solutions have become an integral part of the secure environment. Providing the user 12 color-coded options for networks, the MTP® and LC solutions provide added flexibility and identification of networks.
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 40
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | Modules
Select wiring/polarity.U = Universal R = Straight-through
Defines fiber count.08 = 8-fiber
Select front connector.04 = LC duplex multimode 05 = LC duplex single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select back connector.E6 = MTP® 8-fiber (non-pinned)
multimodeE8 = MTPA 8-fiber (non-pinned)
single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber type.G = Single-mode Ultra (OS2) Q = 50 μm multimode (OM4)
1 4 6
2
5 73
ECM8 - M 08 - - - ULL1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 41
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | Port Breakout Modules
Select front connector.04 = LC duplex, multimode 05 = LC duplex, single-mode Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua Select non-keyed MTP®.E6 = MTP (non-pinned),
multimodeE8 = MTPA (non-pinned),
single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber type.Q = 50 μm multimode (OM4) G = Single-mode Ultra
Select cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select module type.A = Type A B = Type B
Select the cable length.(Lengths are measured from furcation plug to furcation plug) 003-075 ft(1-ft increments measured from MTP to back of module) 001-025 m(1-m increments measured from MTP to back of module)
Select unit of measure.F = Feet M = Meter
1 4
6
2
5
8
107
9
3
ECM8 - - 1 2 4 5 6 7 8 103 9
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 42
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | MTP® Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector.E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
Select the MTP connector.E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Defines end 1 leg length.D = 33-in legs Note – Furcation legs are color coded by fiber type
Defines end 2 leg length.D = 33-in legs Note – Furcation legs are color coded by fiber type
Select wiring/polarity.U = Universal P = Straight-through
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
1
4
9 13
10
11
12
6
2
5
7
8
3
D D S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 43
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | MTP® Extender Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector. (End 1)E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
Select the MTP connector. (End 2)E6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Defines end 1 leg length.D = 33-in legs (-0/+3 in)
Defines end 2 leg length.C = 60-in legs (-0/+3 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.X = Extender trunk (straight-through polarity)
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
1
4
9 13
10
11
12
6
2
5
7
8
3
D C X S2 31 4 6 7 8 9 10 11 13 145 12
14
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 44
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | MTP® Hybrid Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector. (End 1)E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-mode
Select the LC connector. (End 2)79 = LC uniboot, multimode 78 = LC uniboot, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Defines end 1 leg length.D = 33-in legs (-0/+3 in) Note – Furcation legs are color coded by fiber type
Select end 2 leg length.J = 12-in (+3/-0 in) K = 24-in (+3/-0 in) L = 36-in (+3/-0 in) M = 48-in (+3/-0 in) N = 60-in (+3/-0 in) P = 72-in (+3/-0 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.W = Universal hybrid
1
4
9
13
10
11
12
6
2
5
7
8
3
D W S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 45
C Z S2 31 4 6 7 8 9 10 11 13 145 12
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | MTP® Hybrid Extender Trunks
Select grip.G = Grip one end Z = No grip
Select the MTP® connector. (End 1)E6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Select the LC connector. (End 2)79 = LC uniboot, low-loss
multimode78 = LC uniboot, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.08 = 8-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode ultra (OS2)
Select cable type.P = Plenum non-armored A = Plenum BX armored
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Defines end 1 leg length.C = 60-in legs Note – Furcation legs are color coded by fiber type
Select end 2 leg length.J = 12-in (+3/-0 in) K = 24-in (+3/-0 in) L = 36-in (+3/-0 in) M = 48-in (+3/-0 in) N = 60-in (+3/-0 in) P = 72-in (+3/-0 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.Z = Hybrid extender (straight-through polarity)
1
4
9
13
10
11
12
6
2
5
7
8
3
14
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 46
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | Harness
Select the MTP® connector.E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-modeE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Select the LC connector. 79 = LC uniboot, multimode 78 = LC uniboot, single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines fiber count.08 = 8-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode ultra (OS2)
Select cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select leg length.J = 12-in (+3/-0 in) K = 24-in (+3/-0 in) L = 36-in (+3/-0 in) M = 48-in (+3/-0 in) N = 60-in (+3/-0 in) P = 72-in (+3/-0 in) Note – Furcation legs are color coded by fiber type
Select wiring/polarity.A = Type-A polarity B = Type-B polarity
Select the cable length.003-200 ft(1-ft increments measured from MTP to furcation plug and does not include stagger) 001-060 m(1-m increments measured from MTP to furcation plug and does not include stagger)
1 4
9
10
11
12
6
2
5
7
8
3
H 08 - S 1 2 4 5 6 7 8 11103 9 12
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 47
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | MTP® Jumpers
Select the MTP® connector.E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-modeE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Select the MTP connector.E5 = MTP 8-fiber (pinned),
multimodeE7 = MTP 8-fiber (pinned),
single-modeE6 = MTP 8-fiber (non-pinned),
multimodeE8 = MTP 8-fiber (non-pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines fiber count.08 = 8-fiber
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4) G = Single-mode Ultra (OS2)
Defines cable type.E = Plenum interconnect
Select the cable length.003-200 ft(1-ft increments measured from MTP to furcation plug and does not include stagger) 001-060 m(1-m increments measured from MTP to furcation plug and does not include stagger)
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua Defines furcation length.N = No furcation
Select wiring/polarity.A = TIA-568 Type-A
(straight-through)B = TIA-568 Type-B (MTP flip)
1
4
9
10
11
6
2
5
7
8
3
J 08 E - N S 1 2 4 5 6 7 8 11103 9 12
12
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 48
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | MTP® Panels
Select fiber count.08 = 8-fiber16 = 16-fiber24 = 24-fiber32 = 32-fiber
Select adapter color.V1 = BlackV2 = RedV3 = AquaV4 = GreenV6 = BlueV7 = SlateV8 = VioletV9 = OrangeVB = BrownVC = WhiteVE = YellowVF = Rose
1 2
EDGE8 - CP - 1 2
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 49
Preterminated Non-Keyed SolutionsEDGE8™ Solutions | LC Panels
Select shuttered adapter color.AC = BlackAD = AquaAE = BlueAF = GreenAV = VioletDC = RedDD = YellowDE = BrownDF = SlateDG = WhiteDH = OrangeDK = Rose
1
EMOD8 - CP 08 - 1
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 50
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Modules
Select wiring/polarity.U = Universal R = Classic
Defines fiber count.12 = 12-fiber
Select front connector.05 = LC, multimode 04 = LC, single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines back connector.93 = MTP®, low-loss (pinned),
multimode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber type.T = 50 μm multimode (OM3) Q = 50 μm multimode (OM4)G = Single-mode, Ultra (OS2)
1 4 6
2
5 73
ECM - M 12 - - 93 1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 51
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Trunks
Select grip.G = Grip one end Z = No grip
Select end 1 MTP® connector.Non-keyed 75 = MTP (non-pinned),
multimode90 = MTP (non-pinned),
single-mode
Select end 2 MTP connector.Non-keyed 75 = MTP (non-pinned),
multimode90 = MTP (non-pinned),
single-mode No Connector 00 = Pigtail (available on ribbon
interconnect)
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.08 = 08-fiber 48 = 48-fiber 16 = 16-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 32 = 32-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored R = Ruggedized ribbonA = Plenum BX armoredC = Ribbon plenum*R = Ribbon interconnect
(12-fiber only)*
*Available in pigtails only
Select wiring/polarity.U = Universal C = Classic P = Straight-through
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in)0 = Pigtail Note – Furcation legs are color coded by fiber type
Select end 2 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in)0 = Pigtail Note – Furcation legs are color coded by fiber type
1 4
9
1310
12
6
2
5
7
3
S2 31 4 6 7 8 9 10 11 13 145 12
118
14
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 52
6
5
7
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Extender Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.93 = MTP®, low-loss
(pinned), multimode89 = MTP, standard loss
(pinned), single-mode
Select end 2 connector.75 = MTP, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cable
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
Select end 2 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.X = Extender trunk Note – Straight-through polarity
1
4
9
13
10
12
2
3
118
X S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 53
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems LC to LC Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.Non-keyed 04 = LC duplex single-mode05 = LC duplex multimode
No Connector 00 = Pigtail (available on ribbon interconnect)
Select end 2 connector.04 = LC duplex single-mode05 = LC duplex multimode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.06 = 6-fiber 48 = 48-fiber 12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cableC = Ribbon plenumR = MIC 250 cable
(6- and 12-fiber only)
Select jacket color.N = Blue E = Orange G = Green K = Brown S = Slate W = White R = Red B = Black Y = Yellow V = Violet P = Rose A = Aqua
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select end 1 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mmO = Pigtail Note – Furcation legs are color coded by fiber type
Select end 2 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.C = Classic trunk
1 4
4
9
1310
12
6
2
5
7
3
118
C S2 31 4 6 7 8 9 10 11 13 145 12
14
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 54
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Hybrid Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.75 = MTP®, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Select end 2 connector.04 = LC duplex single-mode05 = LC duplex multimode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cable
Select jacket color.N = Blue E = Orange N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in) Note – Furcation legs are color coded by fiber type
Select end 2 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.W = Universal hybrid
1
4
9
13
10
12
6
2
5
73
118
W S2 31 4 6 7 8 9 10 11 13 145 12
14
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 55
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Hybrid Extender Trunks
Select grip.A = Grip one end N = No grip
Select end 1 connector.93 = MTP®, low-loss
(pinned), multimode89 = MTP, standard loss
(pinned), single-mode
Select end 2 connector.04 = LC duplex single-mode05 = LC duplex multimode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber count.12 = 12-fiber 72 = 72-fiber 24 = 24-fiber 96 = 96-fiber 36 = 36-fiber E4 = 144-fiber 48 = 48-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Select cable type.P = Plenum non-armored R = Ruggedized ribbon
(12- to 48-fiber only)A = Armored MIC® 250 cable
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select the cable length.005-999 ft(1-ft increments measured from furcation plug to furcation plug) 002-300 m(1-m increments measured from furcation plug to furcation plug) Note – Longer lengths available upon request
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select end 1 leg length.A = 24-in minimum stagger
(-0/+3 in)B = 36-in minimum stagger
(-0/+3 in)0 = Pigtail Note – Furcation legs are color coded by fiber type
Select end 2 leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.Z = Hybrid extender (straight-through polarity)
1
4
9
1310
12
6
2
5
73
11
8
Z S2 31 4 6 7 8 9 10 11 13 145 12
14
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 56
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Trunk Harnesses
Select end 1 connector.93 = MTP®, low-loss
(pinned), multimode89 = MTP, standard loss
(pinned), single-mode
Select end 2 connector.04 = LC duplex, single-mode05 = LC duplex, multimode 79 = LC duplex, uniboot
multimode78 = LC duplex, uniboot
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines fiber count.12 = 12-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Defines cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.Z = Trunk harnessUniversal polarity (blue to the right).
Select the harness length.003-200 ft(1-ft increments measured from plugto MTP and does not include stagger) 001-060 m(1-m increments measured from plug to MTP and does not include stagger) Note – Longer lengths available upon request
1
9
10
6
2
5
3
11
7
8
H 12 E - Z S 1 2 4 5 6 7 8 11103 9 12
4
12
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 57
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Module Harnesses
Select end 1 connector.75 = MTP, low-loss
(non-pinned), multimode90 = MTP, standard loss
(non-pinned), single-mode
Select end 2 connector.04 = LC duplex single-mode05 = LC duplex multimode79 = LC duplex, uniboot
multimode78 = LC duplex, uniboot
single-mode
Select connector color. N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines fiber count.12 = 12-fiber
Select fiber type.T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode Ultra (OS2)
Defines cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Select leg length.K = 24-in (-0/+4 in), 2.0 mmL = 36-in (-0/+4 in), 2.0 mmM = 48-in (-0/+4 in), 2.0 mmN = 60-in (-0/+4 in), 2.0 mmP = 72-in (-0/+4 in), 2.0 mm Note – Furcation legs are color coded by fiber type
Defines wiring/polarity.W = Module harness(Aqua to the right)
Select the harness length.003-200 ft(1-ft increments measured from plugto MTP and does not include stagger) 001-060 m(1-m increments measured from plug to MTP and does not include stagger) Note – Longer lengths available upon request
1
9
10
6
2
5
3
11
7
8
H 12 E - W S 1 2 4 5 6 7 8 11103 9 12
4
12
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 58
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Closet Connector Housing (CCH) Modules
Select wiring/polarity.U = Universal R = Classic
Select fiber count.12 = 12-fiber 24 = 24-fiber
Select front connector.05 = LC, multimode 04 = LC, single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select back connector.93 = MTP®, low-loss, multimode89 = MTP, single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
1 4 6
2
5 73
CCH - M - - 1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 59
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Integrated Trunk Modules
Defines wiring/polarity.U = Universal
Select front connector.05 = LC, multimode 04 = LC, single-mode
Select back connector.93 = MTP®, low-loss
(pinned), multimode89 = MTP, (pinned), single-mode75 = MTP, low-loss
(non-pinned), multimode90 = MTP, (non-pinned),
single-mode
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select the cable length.040 = 40 ft080 = 80 ft120 = 120 ft160 = 160 ft200 = 200 ft
1 4 6
2
57
3
Preterminated Non-Keyed Solutions
ITM U - 12 - - - - F1 2 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 60
Preterminated Non-Keyed SolutionsEDGE™ Solutions | MTP® Panels
EDGE - CP - 1 2
EDGE - CP - 1 2
Select fiber count.12 = One MTP® adapter24 = Two MTP adapters48 = Four MTP adapters
Select color code.Q1 = Green Q6 = VioletQ2 = Red Q7 = SlateQ3 = Yellow Q8 = WhiteQ4 = Blue Q9 = RoseQ5 = Orange QA = Brown89 = Black E3 = Aqua
1 2
Select fiber count.24 = 24-fiber hex plex adapter48 = 48-fiber hex plex adapter72 = 72-fiber hex plex adapter
Select color code.U1 = Black U2 = RedU4 = Green U3 = AquaU6 = Blue U7 = SlateU8 = Violet U9 = OrangeUB = Brown UC = WhiteUE = Yellow UF = Rose
1 2
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 61
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Plug & Play™ Systems Jumpers
Select end 1 MTP® connector.75 = MTP, low-loss
(non-pinned), multimode89 = MTP, low-loss (pinned),
single-mode90 = MTP, standard loss
(non-pinned), single-mode93 = MTP, low-loss
(pinned), multimode
Select end 2 MTP connector. See options listed above.
Select connector color. (Color applies to both ends)N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Defines fiber count.12 = 12-fiber
Select fiber type.G = Bend-improved
single-mode (OS2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)
Defines cable type.E = Plenum interconnect
Select jacket color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select unit of measure.F = Feet M = Meters
Defines suffix. S = Secure
Defines furcation length.(Could be used for 100G furcation leg lengths)N = No furcation for 40G jumper
Select wiring/polarity.A = TIA-568 Type-A array jumper
(straight-through)B = TIA-568 Type-B array jumper
(MTP flip)C = TIA-568 Type-C array jumper
(pairwise flip)
Select jumper length.1–999
1 4
9
10
11
62
5
7
8
3
J 12 E - N S 1 2 4 5 6 7 8 11103 9 12
12
Preterminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 62
Preterminated Non-Keyed SolutionsEDGE™ Solutions | Cable Assemblies
Select end 1 connector.00 = No connectors (pigtail) Multimode03 = LC PC simplex 05 = LC PC duplex Single-mode02 = LC UPC simplex 04 = LC UPC duplex Always use the lowest code first when constructing part numbers
Select end 2 connector.Multimode03 = LC PC simplex 05 = LC PC duplex Single-mode02 = LC UPC simplex 04 = LC UPC duplex Always use the lowest code first when constructing part numbers
Select fiber count.01 = 1-fiber02 = 2-fiber
Select fiber type.K = 62.5 μm multimode (OM1) T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)G = Single-mode (OM1)
Select cable type.21 = Single-fiber riser 2.0 mm51 = Zipcord riser 2.0 mm28 = Single-fiber plenum 2.0 mm58 = Zipcord plenum 2.0 mm
Select connector 1 color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = AquaZ = Non-keyed LC
Select connector 2 color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = AquaZ = Non-keyed LC
Select assembly length.002-250 (For lengths greater than 999, contact Corning Customer Care)
Select unit of measure.F = Feet M = Meter
Select cable color. Nonstandard colorsBL = Blue GR = Green SL = Slate RD = Red YL = Yellow BR = Brown OR = Orange BL = Black WH = White RS = Rose VI = Violet AQ= Aqua
Standard colorsSingle-mode (OS2) YL = YellowMultimode (OM1)OR = OrangeMultimode (OM3/OM4) AQ = Aqua
1 4
6
5
8
10
7
9
3
- 2 31 4 6 7 8 9 105
2
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 63
Field-Terminated Non-Keyed Solutions
Field-Terminated Non-Keyed Solutions
We offer network security for any organization looking to mitigate privacy or security concerns. Giving the user 12 color-coded options, the LC solution provides added flexibility and easy network identification.
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 64
Field-Terminated Non-Keyed SolutionsCables
Offered in 12 colors, our MIC® (indoor) and FREEDM® (indoor/outdoor) riser-rated cables allow the user to quickly identify different networks. These cables are also available with interlocking and all-dielectric armor for added physical protection and peace of mind.
The following colors are available:
Please contact Corning Customer Care for part numbers and lead times.
Email: [email protected]
Phone Number: 1-800-743-2675
Blue Red
Orange Black
Green Yellow
Brown Purple
Slate Rose
White Aqua
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 65
Field-Terminated Non-Keyed SolutionsConnectors
Select fiber type.000 = 62.5 μm050 = 50 μm200 = 8.3 μm (OS2)
Select connector type.99 = LC99-X = LC (OM3/OM4)94 = LC APC
1 2
95 - - 1
Defines connector type.11 = LC connector
Select jacket/fiber size.9 = 900 μm2 = 1.6 mm/2.0 mm3 = 3.0 mm Note - Each package contains 100 boots
Note - Order UniCam® plus colored boots for non-keyed UniCam connectors.
Select boot color.N = Blue Y = Yellow C = Slate A = Aqua R = Red G = Green B = Black W = White
1
2
3
95 - 400 - 11 - BP - 31 2
UniCam® LC Connectors
UniCam® LC Keyed Connector Boots
2
Field-Terminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 66
Field-Terminated Non-Keyed SolutionsAdapters
Select adapter color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
1
ADP - DLC0 - CC RF - CLS1
LC Duplex Adapter Non-Keyed to Non-Keyed
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 67
Select fiber count.06 = 6-fiber (three duplex adapters)08 = 8-fiber (four duplex adapters)12 = 12-fiber (six duplex adapters)16 = 16-fiber (eight duplex adapters)24 = 24-fiber (12 duplex adapters)
Select adapter color.AC = Black DD = YellowAD = Aqua DE = BrownAE = Blue DF = SlateAF = Green DG = WhiteDJ = Violet DH = OrangeDC = Red DK = Rose
1 2
Field-Terminated Non-Keyed SolutionsCCH Panels
Select fiber count.06 = 6-fiber (three duplex adapters)08 = 8-fiber (four duplex adapters)12 = 12-fiber (six duplex adapters)16 = 16-fiber (eight duplex adapters)24 = 24-fiber (12 duplex adapters)
Select adapter color.A9 = Blue BJ = VioletBH = Green BK = OrangeBE = Red BL = RoseBF = Black BM = SlateBG = Yellow BP = WhiteBN = Brown E4 = Aqua
1 2
1
CCH - CP - 1 2
CCH - CP - 1 2
Closet Connector Housing (CCH) Non-Keyed to Non-Keyed Non-Shuttered
Closet Connector Panel (CCH) Non-Keyed to Non-Keyed Shuttered
Field-Terminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 68
Field-Terminated Non-Keyed SolutionsCloset Connector Housing (CCH) Pigtailed Modules and Panels
Select module or panel.RM = ModuleCP = Panel
Select fiber count.06 = 6-fiber08 = 8-fiber12 = 12-fiber16 = 16-fiber24 = 24-fiber
Select color and adapter type.Non-Shuttered LC AdaptersA9 = Blue BJ = VioletBH = Green BK = OrangeBE = Red BL = RoseBF = Black BM = SlateBG = Yellow BP = WhiteBN = Brown E4 = Aqua
Shuttered LC AdaptersAC = Black DD = YellowAD = Aqua DE = BrownAE = Blue DF = SlateAF = Green DG = WhiteDJ = Violet DH = OrangeDC = Red DK = Rose
Select fiber type.K = 62.5 μm multimode (OM1)C = 50 μm multimode (OM2)S = 50 μm multimode (OM4)R = Single-mode (OS2)
Select cable type.H = MIC® cable subunit
(standard fiber cable option)J = Ribbon fiber
1
2
5
3
CCH - - - - P03 1 2 3 4 5
4
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 69
Field-Terminated Non-Keyed SolutionsCloset Connector Housing (CCH) Pigtailed Splice Cassettes
Select fiber count.06 = 6-fiber08 = 8-fiber12 = 12-fiber16 = 16-fiber24 = 24-fiber
Select color and adapter type. Non-Shuttered LC AdaptersA9 = Blue BJ = VioletBH = Green BK = OrangeBE = Red BL = RoseBF = Black BM = SlateBG = Yellow BP = WhiteBN = Brown E4 = Aqua
Shuttered LC AdaptersAC = Black DD = YellowAD = Aqua DE = BrownAE = Blue DF = SlateAF = Green DG = WhiteDJ = Violet DH = OrangeDC = Red DK = Rose
Select fiber type.K = 62.5 μm multimode (OM1)B = 50 μm multimode (OM2)T = 50 μm multimode (OM3)Q = 50 μm multimode (OM4)R = Single-mode (OS2)
Select splicing type.E = Single-fiber splicingJ = Ribbon splicing (only for
fiber counts of 12 or 24)
1
2
3
4
CCH - CS - - - P00 1 2 3 4
Field-Terminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 70
Field-Terminated Non-Keyed SolutionsWall-Plate Outlets (WLL) Single-Gang
Select number of ports and orientation.A = 1, straight M = 1, angledB = 2, straight N = 2, angledC = 3, straight P = 4, angledD = 4, straightE = 6, straight
Select color for each port.A9 = Blue BJ = VioletBH = Green BK = OrangeBE = Red BL = RoseBF = Black BM = SlateBG = Yellow BP = WhiteBN = Brown E4 = Aqua
1 2
WLL A - 1
Port
2
1 2 3 4 5 6
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 71
3
Field-Terminated Non-Keyed SolutionsWorkstation Multimedia Outlets (WMO)
Select number of fiber connections per panel.1 = 1-fiber connection2 = 2-fiber connections4 = 4-fiber connections
(SC duplex, LC duplex)
Select color for each port.A9 = Blue BJ = VioletBH = Green BK = OrangeBE = Red BL = RoseBF = Black BM = SlateBG = Yellow BP = WhiteBN = Brown E4 = Aqua
Select housing color.35 = Beige85 = White
1 2
WMO - CP0 - - - 1 2 3
Field-Terminated Non-Keyed Solutions
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 72
7
Field-Terminated Non-Keyed SolutionsFiber-to-the-Desk Module
Select wiring/polarity.U = Universal R = Classic
Defines fiber count.12 = 12-fiber
Select front connector.04 = LC duplex, single-mode05 = LC duplex, multimode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = Aqua
Select back connector.93 = MTP®, low-loss (pinned),
multimode89 = MTP, (pinned),
single-mode
Select connector color.N = Blue R = Red E = Orange B = Black G = Green Y = Yellow K = Brown V = Violet S = Slate P = Rose W = White A = AquaZ = Non-keyed LC
Select fiber type.T = ClearCurve® (OM3) Q = ClearCurve (OM4) G = XB, single-mode
Select module type.J = Junction box F = Floor box
1
4
6
2
5
8
3
MAM - M - 12 - - - 1 82 4 6 73 5
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 73
Additional Products and Resources
Additional Products and Resources
Pair your optical preterminated and field-terminated connectivity solutions with our broad range of hardware options to ensure maximum security, flexibility, and manageability. We also offer valuable tools and resources – from design and technical assistance, to an online bill-of-materials generator – to support your network today as well as tomorrow.
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 74
Rack-Mountable Hardware Solutions
Hardware Type Available Sizes Secure Solution Required
EDGE-01U
EDGE-01U-SP
EDGE-02U
EDGE-04U
EDGE-01U
EDGE-01U-SP
EDGE-02U
EDGE-04U
CCH-01U
CCH-02U
CCH-03U
CCH-04U
PCH-01U
PCH-02U
PCH-04U
Hardware Solutions
EDGE8™ Hardware EDGE8 Modules and Panels
EDGE™ Hardware EDGE Modules and Panels
Closet ConnectorHousing (CCH)
CCH Panels and PigtailedCassettes
Pretium™ ConnectorHousing (PCH)
Plug & Play™ Modules and MTP® ConnectorPanels
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 75
Wall-Mountable Hardware Solutions
Hardware Type Available Sizes Secure Solution Required
WCH-02P
WCH-04P
WCH-06P
SCH-01C
SPH-01P
SMH-01M
Hardware Solutions
Additional Products and Resources
Wall-MountableCloset Housing(WCH)
CCH Panelsand PigtailedCassettes
Single-Cassette Housing (SCH)
CCH PigtailedCassettes
Single-Panel Housing (SPH)
CCH Panels
Single-Module Housing (SMH)
CCH Modules
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 76
Fiber-to-the-Desk Hardware Solutions
Hardware Type Available Sizes Secure Solution Required
EDGE8-SMH
EDGE-SMH
Ceiling/Floor/Wall-Mountable Hardware Solutions
Hardware Type Available Sizes Secure Solution Required
FZB-04U
FZB-04P
EDGE8™ andEDGE™ Single-ModuleHousing
Hardware Solutions
Fiber Zone Box (FZB)
Wall Plate Outlet (WLL)
Workstation MultimediaOutlet (WMO)
Fiber-to-the-DeskModule (MAM)
EDGE8 Modules
CCH Panels andPlug & Play™Modules
See keyed and non-keyed optionsin field-terminated sections.
EDGE Modules
See keyed and non-keyed optionsin field-terminated sections.
See keyed and non-keyed optionsin field-terminated sections.
Corning Optical Communications Ordering Guide | LAN-1852-AEN | Page 77
BOM Tool This fast, free Microsoft Excel-based tool makes it easy to select the products you need for your next project. The tool provides product descriptions, part numbers, and links to spec sheets while allowing you to adjust quantities, which can then be emailed from your own computer.
Customer Care 800-743-2675 (U.S. and Canada) +1-828-901-5000 (International) This is no generic call center – our customer care representatives are technically trained and work closely with our engineers to understand and support our customers’ needs.
Drawings Resource Center Your complete source for our optical hardware component drawings. Available in PDF (Adobe® Acrobat®), DXF (AutoCAD®), VSS (Visio® Stencil) formats, and building information modeling (BIM) objects for Revit® and can be downloaded and inserted into your bid specifications and design.
Engineering Services It takes more than products to deliver reliable connectivity. From us, you can expect collaborative presale and post-sale global support for your network today to prepare it for tomorrow’s demands.
Connect with our engineering professionals at any phase of your project to take advantage of their training, experience, and equipment for a cost-effective Total Quality result. Our system engineers, application engineers, and field engineers offer design and training services, technical assistance, and customer support resources.
LANscape® Network of Preferred Installers (NPI) Improve your network by using our network of preferred installers. Corning-trained contractors meet our stringent requirements for technical and financial strength and have a proven dedication to quality installations.
On-Demand Videos We have an ever-growing library of how-to videos on-demand, on our website, or on our YouTube channel. Become a subscriber today!
Online Resource Library Our online resource library gives you all the technical information you need, from specification to installation videos to tutorials, all in one easy, central location at your fingertips.
SEE the LIGHT® Fiber Optic Training Corning SEE the LIGHT hosts a multitude of training opportunities ranging from live and recorded webinars, free hands-on fiber optic seminars, and paid intensive multiday hands-on and design courses throughout the United States, Canada, and CALA.
Spanish-Language Tools Hablamos español aquí. From product information to system calculators, our expanding library of Spanish language materials ensures you and your customers get the in formation you need, how you need it.
Technical Services 800-743-2673 When you need access to a technical expert, we deliver it, 24/7. The Technical Support Line provides our customers 24/7 phone access to our engineers and technicians, providing assistance on our product specifications, applications, use, and performance.
Video Library Tool This tool makes it easy to link directly to the video you want on the topic you need and will be updated regularly as Corning Optical Communications adds new videos to its library.
Tools and Resources
Additional Products and Resources
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcommCorning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2014, 2017 Corning Optical Communications. All rights reserved. LAN-1852-AEN / September 2017