SELECTION GUIDE BULLETIN 1492 IEC Terminal Block Line Extension

SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

SELECTION GUIDE

BULLETIN 1492IEC Terminal Block Line Extension

Page 2: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed
Page 3: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492Screw Connection Terminal Blocks

1Visit our website: www.ab.com/catalogs

Preferred availability cat. nos. are printed in bboolldd

Regulatory Information

Certifications

Allen-Bradley terminal blocks generally have been designed to meetthe requirements of one or more regulatory bodies. Most productshave also been tested per additional standards. The following is alisting of some of the regulatory bodies and standards which applyto Allen-Bradley terminal block products. See the particular productdescription for information on specific certifications and ratings.

(Underwriters Laboratories) — Devices in this catalog withone of these ratings have been tested by Underwriters Laboratoriesand meet the requirements of one or more of the following UnitedStates Standards:

UL 467 — Grounding and Bonding Equipment

UL 486E — Equipment Wiring Terminals for Use with Aluminumand/or Copper Conductors

UL 1059 — Standard for Terminal Blocks

Reference UL files E34648, E40735, E160646

(Underwriters Laboratories) — Devices in this catalog withthis rating have been tested by Underwriters Laboratories and meetthe requirements of the following Canadian Standard:

CSA 22.2 No. 158 — Terminal BlocksReference UL file E40735

(Canadian Standards Association) — Devices in this catalogwith this rating have been tested by the Canadian StandardsAssociation and meet the requirements of the following CanadianStandard:

CSA 22.2 No. 158 — Terminal Blocks

Reference CSA files LR67896

Terminal blocks listed in this catalog meet the requirementsof the Low Voltage Directive put forth by the European Union.Devices have been tested and comply with one or more of thefollowing European Norms:

EN 60947-1 — Low Voltage Switchgear and Controlgear: GeneralRules

EN 60947-7-1 — Low Voltage Switchgear and Controlgear:Terminal Blocks for Copper Conductors

EN 60947-7-2 — Low Voltage Switchgear and Controlgear:Protective Conductor Terminal Blocks for Copper Conductors

EN 60947-7-3 — Low Voltage Switchgear and Controlgear: SafetyRequirements for Fuse Terminal Blocks

ATEX — Devices listed in this catalog with “ATEX” ratingsmeet the following European Norms per DEMKO or KEMA, ApprovalCertification Bodies for the European Union:

EN 50014 — Electrical Apparatus for Potentially ExplosiveAtmospheres — General Requirements

EN 50019 — Electrical Apparatus for Potentially ExplosiveAtmospheres — Increased Safety “e”

Contact your local Rockwell Automation sales office or Allen-Bradley distributor for a copy of the certificate.

Ex e II — Many 1492-J, 1492-L, and 1492-W terminal blocks in thiscatalog meet the following Canadian Standards per UnderwritersLaboratories:

E79-0-95 — Electrical Apparatus for Explosive Atmospheres —Part 0 — General Requirements

E79-7-95 — Electrical Apparatus for Explosive Atmospheres —Part 7 — Increased Safety “e”

These products are suitable for Class I, Zone 1 HazardousLocations. Reference UL file E187022. Contact your local Allen-Bradley distributor for more information.

AEx e II — Devices listed in this catalog with an “AEx e II” ratingmeet the following United States Standard per UnderwritersLaboratories:

UL 2279 — Standard for Electrical Equipment for Use in Class I,Zone 0, 1, and 2 Hazardous (Classified) Locations

These products are suitable for Class I, Zone 1 HazardousLocations. Reference UL file E187022. Contact your local RockwellAutomation sales office or Allen-Bradley distributor for moreinformation.

Lloyd’s Register — Many 1492-H, 1492-J, 1492-L, and 1492-Wterminal blocks in this catalog have been certified for use in marine,off-shore, and industrial installations per the following standard:

Lloyd’s Register Test Specification No. 1:1996

Contact your local Rockwell Automation sales office or Allen-Bradley distributor for a copy of the certificate.

Page 4: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

2Visit our website: www.ab.com/catalogs

Preferred availability cat. nos. are printed in bboolldd

Introduction

The Allen-Bradley Line of IEC Terminal Blocks…International Products for a Worldwide Marketplace

The Allen-Bradley Bulletin 1492-J line of internationally approvedIEC style terminal blocks offers a wide range of features andbenefits ideally suited for many industrial applications. The 1492-Jline has been designed to meet the tough requirements of almostevery industrial application. Functional, internationally approved,finger-safe, and cost-effective — the Allen-Bradley Bulletin 1492-Jline.

Products Available in the Bulletin 1492 Screw TerminalBlock Line

Our family of IEC terminal blocks consists of many different types ofblocks, from general feed-through terminal blocks for control wiringto specialty blocks for grounding and isolating. We even offerthermocouple terminal blocks, specifically designed fortemperature-dependent process control applications.

Products offered within the Bulletin 1492 Screw Terminal Block lineinclude:

Feed-Through Blocks, capable of accommodating #30...4.7/0AWG (0.2...120 mm2) wireGrounding Blocks for grounding a given circuit to the DIN RailMini Blocks for applications where panel space is at a premiumTwo-Level Blocks that double circuit wiring densityMulti-Conductor Blocks that allow splitting or joining of controlcircuitsThree-Level Sensor Blocks for coordination of three-wire sensorgroupsIsolation Blocks for circuit isolation during testing andtroubleshootingFuse Blocks, with and without blown fuse indication, for easilyintegrated overcurrent protectionElectrical Component Blocks that allow the insertion of fixedcomponents into control circuits. Available components includeresistors, diodes, surge suppression circuits, and shunt bars.Return Blocks that have both terminations on the same side ofthe terminal block allowing the rail to be mounted next to the wallof an enclosurePlug-In Style Blocks that allow the insertion of removable plugsinto control circuits. Available plugs include a Disconnect Plug, aFuse Plug, and a Component Plug which will accommodatevarious electrical componentsThermocouple Terminal Blocks (Types B, E, J, K, N, S, T) fortemperature control applicationsA wide variety of Snap-In Markers for individual or group circuitidentificationMulti-pole insulated Center Jumpers which provide a convenientmethod of commoning control circuits

Materials and Design Features

The Bulletin 1492-J line is designed for safety, installation ease, andruggedness. Features using these design criteria include thefollowing:

Tin-plated terminals and steel screws for corrosion resistance(Bulletin 1492-W terminal blocks have nickel-plated terminals andstainless steel screws)High copper content copper alloy for excellent conductivityFour-sided wire funnel guides for easy wire insertionFinger-safe housings to prevent accidental contact with livecircuitsInternational approvals for worldwide useDIN Rail (Cat. No. 199-DR1) mountability, allowing terminal blocksto be placed on the same channel as contactors, starters, relays,and other DIN Rail-mounted control devicesSelf-extinguishing, polyamide 6.6 housing material with UL 94-V0flammability rating (Bulletin 1492-W terminal blocks have UL 94-V2flammability rating)Backed out screws for fast wiring

Page 5: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

3Visit our website: www.ab.com/catalogs

Preferred availability cat. nos. are printed in bboolldd

Standard Feed Through Blocks

1492-J3 1492-J4

Dimensions are not intended to beused for manufacturing purposes.Note: Height dimension is measured

from top of rail to top of terminalblock.

0.20"(5.1 mm)

2.36" (60 mm)

1.56

" (3

9.5

mm

)

0.24"(6.1 mm)

2.36" (60 mm)

1.56

" (3

9.5

mm

)

Specifications Feed-through terminal block Feed-through terminal blockCertifications CSA IEC ATEX CSA IEC ATEX

Voltage Rating 600V AC/DC 800V AC/DC 550VAC/DC 600V AC/DC 800V AC/DC 690V

AC/DCMaximum Current 25 A 20 A 24 A 21 A 35 A 25 A 32 A 28 A

Wire Range (Rated Cross Section) #22…12 AWG #26…12 AWG 2.5 mm22.5 mm2

(#20…14AWG)

#22…10 AWG #26…10 AWG 4 mm24 mm2

(#20…12AWG)

Wire Strip Length 0.39 in. (10 mm) 0.39 in. (10 mm)Recommended Tightening Torque 4.5…7.1 lb•in. (0.5…0.8 N•m) 9.0 lb•in. (1.0 N•m)Density 59 pcs/ft (196 pcs/m) 49 pcs/ft (163 pcs/m)Housing Temperature Range –58…+248 °F (–50…+120 °C) –58…+248 °F (–50…+120 °C)Short-Circuit Current Rating See Page 8

Terminal Blocks Cat. No. Pkg Qty. Cat. No. Pkg Qty.Color: Grey 1492-J3 100 1492-J4 100

Red 1492-J3-RE 100 1492-J4-RE 100Blue 1492-J3-B 100 1492-J4-B 100

Black 1492-J3-BL 100 1492-J4-BL 100Green 1492-J3-G 100 1492-J4-G 100Yellow 1492-J3-Y 100 1492-J4-Y 100

Orange 1492-J3-OR 100 1492-J4-OR 100Brown 1492-J3-BR 100 1492-J4-BR 100White 1492-J3-W 100 1492-J4-W 100Violet 1492-J3-V 100 1492-J4-V 100

Mounting Rails:1 m Symmetrical DIN (Steel) 199-DR1 10 199-DR1 10

1 m Symmetrical DIN (Aluminum) 1492-DR5 10 1492-DR5 101 m Hi-Rise Sym. DIN (Aluminum) 1492-DR6 2 1492-DR6 21 m Angled Hi-Rise Sym. DIN (Steel) 1492-DR7 2 1492-DR7 2

End Barriers Grey 1492-EBJ3 50 1492-EBJ3 50Blue 1492-EBJ3-B 50 1492-EBJ3-B 50

Yellow 1492-EBJ3-Y 50 1492-EBJ3-Y 50End Anchors and Retainers:

Screwless End Retainer 1492-ERL35 20 1492-ERL35 20

DIN Rail — Normal Duty 1492-EAJ35 100 1492-EAJ35 100DIN Rail — Heavy Duty 1492-EAHJ35 50 1492-EAHJ35 50

Jumpers:Screw Center Jumper — 10-pole 1492-CJJ5-10 20 1492-CJJ6-10 20

Screw Center Jumper — 4-pole 1492-CJJ5-4 50 1492-CJJ6-4 50Screw Center Jumper — 3-pole 1492-CJJ5-3 50 1492-CJJ6-3 50Screw Center Jumper — 2-pole 1492-CJJ5-2 50 1492-CJJ6-2 50Plug-in Center Jumper — 50-Pole 1492-CJLJ5-50 10 1492-CJLJ6-41 (41-pole) 10Plug-in Center Jumper — 10-Pole 1492-CJLJ5-10 20 1492-CJLJ6-10 20Plug-in Center Jumper — 9-Pole 1492-CJLJ5-9 20 — —Plug-in Center Jumper — 8-Pole 1492-CJLJ5-8 20 — —Plug-in Center Jumper — 7-Pole 1492-CJLJ5-7 20 — —Plug-in Center Jumper — 6-Pole 1492-CJLJ5-6 20 — —Plug-in Center Jumper — 5-Pole 1492-CJLJ5-5 20 — —Plug-in Center Jumper — 4-Pole 1492-CJLJ5-4 60 1492-CJLJ6-4 60Plug-in Center Jumper — 3-Pole 1492-CJLJ5-3 60 1492-CJLJ6-3 60Plug-in Center Jumper — 2-Pole 1492-CJLJ5-2 60 1492-CJLJ6-2 60Insulated Side Jumper — 24-Pole 1492-SJ5B-24 50 — —Insulated Side Jumper — 10-Pole 1492-SJ5B-10 50 — —Screw Type Jumper Notching Tool 1492-T1 1 1492-T1 1

Other Accessories:Partition Plate 1492-EBJ16 20 1492-EBJ16 20

Test Plug Socket 1492-TPS23 20 1492-TPS23L 50Test Plug 1492-TP23 20 1492-TP23 20Test Plug (Stackable) 1492-TPJ5 25 1492-TPJ6 25Electrical Warning Plate 1492-EWPJ5 25 1492-EWPJ5 25

Marking Systems:Snap-in Marker Cards

1492-MR5X12 (120/card) 5 1492-MR6X12 (120/card) 51492-M5X5 (200/card) 5 1492-M6X5 (200/card) 5

Use of center jumpers may affect spacings, requiring derating of terminal blocks. See page 12-78 for details.

Page 6: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

4Visit our website: www.ab.com

Preferred availability cat. nos. are printed in bboolldd

Standard Feed Through Blocks

1492-J120

Dimensions are not intended to be usedfor manufacturing purposes.Note: Height dimension is measured

from top of rail to top of terminalblock.

3.58” (91 mm)

1.06”(27 mm)

3.31

” (8

4 m

m)

Specifications Feed-through terminal block

Certifications CSA IEC

Voltage Rating 1000VAC/DC

Maximum Current 228 A 220 A 269 A

Wire Range (Rated Cross Section) #4...4.7/0 AWG #4…4/0 AWG 16…120 mm2

Wire Strip Length 1.06 in. (27 mm)

Recommended Tightening Torque 141.6 lb•in. (16.0 N•m)

Density 11 pcs/ft (37 pcs/m)

Housing Temperature Range -58...+248 °F (-50...+120 °C)

Short-Circuit Current Rating See Page 8

Terminal Blocks Cat. No. Pkg Qty.

Color: Grey 1492-J120 5

Blue 1492-J120-B 5

Accessories Cat. No. Pkg Qty.

Mounting Rails:1 m Symmetrical Heavy Duty DIN(Steel, Unslotted)

199-DR4 5

1 m Angled Hi-Rise Sym. DIN (Steel) 1492-EAHJ35 50

1 m Symmetrical Heavy Duty DIN(Copper, Unslotted) 1492-DR8 5

1 m Symmetrical Heavy Duty DIN(Steel) 1492-DR9 5

End Barriers 1492-CJJ27-4 5

Jumpers:Screw Center Jumper — 4-pole 1492-CJJ27-4 5

Screw Center Jumper — 3-pole 1492-CJJ27-3 5

Screw Center Jumper — 2-pole 1492-CJJ27-2 5

Other Accessories:Control Circuit Tap 1492-J120A 5

Marking Systems:Snap-in marker cards 1492-MR8X12 (84/card) 5

Snap-in marker cards 1492-M7X12 (108/card) 5

Auxiliary connection, allowing a single additional wire connection (#26...8 AWG)

Page 7: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

5Visit our website: www.ab.com/catalogs

Preferred availability cat. nos. are printed in bboolldd

Grounding Blocks

1492-JDG4 1492-JDG4C

Dimensions are not intended to be usedfor manufacturing purposes.Note: Height dimension is measured

from top of rail to top of terminalblock.

0.24" (6.1 mm)

2.39" (60.7 mm)

2.52

" (6

4.1

mm

)

0.24" (6.1 mm)

2.39" (60.7 mm)

2.52

" (6

4.1

mm

)

Specifications Two-circuit terminal block with one feed-through and onegrounding Two-level grounding terminal block with commoning bar

Certifications CSA IEC ATEX CSA IEC ATEX

Voltage Rating 600VAC/DC

300VAC/DC

800VAC/DC

550VAC/DC —

Maximum Current 35 A 30 A 32 A 28 A Grounding

Wire Range (Rated Cross Section) #26…10 AWG 4 mm2 4 mm2 #26…10 AWG 4 mm2 4 mm2

Wire Strip Length 0.31 in. (8 mm) 0.31 in. (8 mm)

Recommended Tightening Torque 4.5…8.8 lb•in. (0.5…1.0 N•m) 4.5…8.8 lb•in (0.5…1.0 N•m)

Mounting Torque — Center Screw — —

Density 49 pcs/ft (163 pcs/m) 49 pcs/ft (163 pcs/m)

Housing Temperature Range –58…+248 °F (–50…+120 °C) –58…+248 °F (–50…+120 °C)

Short-Circuit Current Rating See Page 8

Terminal Blocks Cat. No. Pkg Qty. Cat. No. Pkg Qty.

Color: Grey 1492-JDG4 100 — —

Green/Yellow — — 1492-JDG4C 100

Accessories Cat. No. Pkg Qty. Cat. No. Pkg Qty.

Mounting Rails:1 m Symmetrical DIN (Steel) 199-DR1 10 199-DR1 10

1 m Symmetrical DIN (Aluminum) 1492-DR5 10 1492-DR5 10

1 m Hi-Rise Sym. DIN (Aluminum) 1492-DR6 2 1492-DR6 2

1 m Angled Hi-Rise Sym. DIN (Steel) 1492-DR7 2 1492-DR7 2

End Barrier Grey 1492-EBJD4 20 1492-EBJD4 20

Jumpers:Screw Center Jumper — 10-pole 1492-CJLJ6-10 20 1492-CJLJ6-10 —

Screw Center Jumper — 4-pole 1492-CJLJ6-4 60 1492-CJLJ6-4 —

Screw Center Jumper — 3-pole 1492-CJLJ6-3 60 1492-CJLJ6-3 —

Screw Center Jumper — 2-pole 1492-CJLJ6-2 60 1492-CJLJ6-2 —

End Anchors and Retainers:Screwless End Retainer 1492-ERL35 20 1492-ERL35 20

DIN Rail — Normal Duty 1492-EAJ35 100 1492-EAJ35 100

DIN Rail — Heavy Duty 1492-EAHJ35 50 1492-EAHJ35 50

Marking Systems:Snap-in marker cards 1492-MR6X8 (120/card) 5 1492-MR6X8 (120/card) 5

Snap-in marker cards 1492-M6X5 (200/card) 5 1492-M6X5 (200/card) 5

Page 8: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

6Visit our website: www.ab.com

Preferred availability cat. nos. are printed in bboolldd

Isolation Blocks

1492-JKD3 1492-JKD4

Dimensions are not intended to be usedfor manufacturing purposes.Note: Height dimension is measured

from top of rail to top of terminalblock.

0.20"(5.1 mm)

2.36" (60 mm)

1.88

" (4

7 m

m)

Specifications Feed through terminal block with knife disconnect Feed-through terminal block with knife disconnect

Certifications CSA IEC CSA IEC

Voltage Rating 300V AC/DC 500V AC/DC 600V AC/DC 300V AC/DC 400V AC/DC

Maximum Current 10 A 24 A 22 A 10 A 32 A

Wire Range (Rated Cross Section) #22…12 AWG 2.5 mm2 #22…10 AWG 0.05…4.0 mm2

Fuse Size (Dummy Fuse Supplied) — 1/4 in. x 1-1/4 in.

Wire Strip Length 0.39 in. (10 mm) 0.512 in. (13 mm)

Recommended Tightening Torque 7.1 lb•in. (0.8 N•m) 9.0 lb•in. (1.0 N•m)

Density 49 pcs/ft (163 pcs/m) 49 pcs/ft (163 pcs/m)

Housing Temperature Range –58…+248 °F (–50…+120 °C) –58…+248 °F (–50…+120 °C)

Short-Circuit Current Rating See Page 8

Terminal Blocks Cat. No. Pkg Qty. Cat. No. Pkg Qty.

Color: Grey 1492-JKD3 50 1492-JKD4 50

Blue 1492-JKD3-B 50 1492-JKD4-B 50

with Test Points Grey — — 1492-JKD4TP 50

Accessories Cat. No. Pkg Qty. Cat. No. Pkg Qty.

Mounting Rails:1 m Symmetrical DIN (Steel) 199-DR1 10 199-DR1 10

1 m Symmetrical DIN (Aluminum) 1492-DR5 10 1492-DR5 10

1 m Hi-Rise Sym. DIN (Aluminum) 1492-DR6 2 1492-DR6 2

1 m Angled Hi-Rise Sym. DIN (Steel) 1492-DR7 2 1492-DR7 2

End Barriers Grey 1492-EBJ3 50 1492-EBJ3 50

Blue 1492-EBJ3-B 50 1492-EBJ3-B 50

End Anchors:Screwless End Retainer 1492-ERL35 20 1492-ERL35 20

DIN Rail — Normal Duty 1492-EAJ35 100 1492-EAJ35 100

DIN Rail — Heavy Duty 1492-EAHJ35 50 1492-EAHJ35 50

Jumpers:Plug-in Center Jumper — 50-Pole 1492-CJLJ5-50 10 — —

Plug-in Center Jumper — 41-Pole — — 1492-CJLJ6-41 10

Plug-in Center Jumper — 10-Pole 1492-CJLJ5-10 20 1492-CJLJ6-10 20

Plug-in Center Jumper — 9-Pole 1492-CJLJ5-9 20 — —

Plug-in Center Jumper — 8-Pole 1492-CJLJ5-8 20 — —

Plug-in Center Jumper — 7-Pole 1492-CJLJ5-7 20 — —

Plug-in Center Jumper — 6-Pole 1492-CJLJ5-6 20 — —

Plug-in Center Jumper — 5-Pole 1492-CJLJ5-5 20 — —

Plug-in Center Jumper — 4-Pole 1492-CJLJ5-4 60 1492-CJLJ6-4 60

Plug-in Center Jumper — 3-Pole 1492-CJLJ5-3 60 1492-CJLJ6-3 60

Plug-in Center Jumper — 2-Pole 1492-CJLJ5-2 60 1492-CJLJ6-2 60

Insulated Side Jumper — 24-Pole 1492-SJ5B-24 50 — —

Insulated Side Jumper — 10-Pole 1492-SJ5B-10 50 — —

Uninsulated Side Jumper — 10-Pole — — 1492-N49 10

Side Jumper — Insulating Sleeve — — 1492-SJS 10

Screw Type Jumper Notching Tool 1492-T1 1 — —

Other Accessories:Partition Plate 1492-EBJ16 20 — —

Marking Systems:Snap-in marker cards 1492-MR5X12 (120/card) 5 1492-MR6X12 (120/card) 5

Snap-in marker cards 1492-M5X5 (200/card) 5 1492-M6X5 (200/card) 5

Page 9: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

7Visit our website: www.ab.com/catalogs

Preferred availability cat. nos. are printed in bboolldd

Accessories

Screwless Center Jumpers

Auxiliary Circuit Tap

Note: When using multiple screwless jumpers in 1492-J3, -J2Q, or -J4 terminal blocks, the following rules apply when going across differentpotentials with jumpers cut out.

1. When using all 3 channels, or 2 side-by-side channels, de-rate to 125V

2. When using 2 outside channels (leaving the center channel open), de-rate to 400V

Note: Auxiliary connection, allowing a single additional wire connection (#26...8 AWG).

Photo For Use With Pkg Qty. Cat. No.

1492-J50 5 1492-J50A

1492-J70 5 1492-J70A

1492-J120 5 1492-J120A

Photo For Use With Color Pkg Qty. Cat. No.

1492-LM3, LC3, LDC3,LDAG3, LDG3P, JKD3…,

J3P…, J3, J3TW, LDG3ND, LD3N,LDG3N

Yellow 60 1492-CJLJ5-2

Red 60 1492-CJLJ5-2-R

Blue 60 1492-CJLJ5-2-B

Black 60 1492-CJLJ5-2-BL

Yellow 60 1492-CJLJ5-3

Red 60 1492-CJLJ5-3-R

Blue 60 1492-CJLJ5-3-B

Black 60 1492-CJLJ5-3-BL

Yellow

60 1492-CJLJ5-4

20 1492-CJLJ5-5

20 1492-CJLJ5-6

20 1492-CJLJ5-7

20 1492-CJLJ5-8

20 1492-CJLJ5-9

20 1492-CJLJ5-10

Red 20 1492-CJLJ5-10-R

Blue 20 1492-CJLJ5-10-B

Black 20 1492-CJLJ5-10-BL

White 20 1492-CJLJ5-10-W

Yellow 10 1492-CJLJ5-50

Red 10 1492-CJLJ5-50-R

Blue 10 1492-CJLJ5-50-B

Black 10 1492-CJLJ5-50-BL

White 10 1492-CJLJ5-50-W

Page 10: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Bulletin 1492

Screw Connection Terminal Blocks

8Visit our website: www.ab.com

Preferred availability cat. nos. are printed in bboolldd

Short-Circuit Current Ratings

Fuse Ratings

Cat. No.

Wire CU AWG Overcurrent Protection Fuse Required Class/Max. Amp Rating SCCR, RMSSym A 600V

Max. Torque lb•in.Line Load J T RK1 RK5 G CC1492-J3 14…12 14…12 30 30 — — 30 30 100, 000 4.5…7.11492-J4 14…10 14…10 60 60 30 — 60 30 100, 000 9.01492-J6 14…8 14…8 100 100 60 30 60 30 100, 000 14.21492-J10 14…6 14…6 100 100 60 30 60 30 100, 000 20.41492-J16 14…4 14…4 100 100 60 30 60 30 100, 000 35.01492-J35 12…1/0 12…1/0 200 200 100 30 60 30 100, 000 51.01492-J50 6…1/0 6…1/0 200 200 100 30 60 30 100, 000 31.01492-J70 1/0…3/0 1/0…3/0 400 400 200 100 60 30 100, 000 88.51492-J120 4…4/0 4…4/0 400 400 200 100 60 30 100, 000 105.0

Overcurrent Ratings

Cat. No.Wire CU AWG

(Line and Load)Overcurrent Protection

Device Required Max. AmpSCCR, RMS Sym A

480YSCCR, RMS Sym. A

600Y Torque lb•in.

1492-J3 14…12

140M-D8E-B__ 16 65,000 30,000

4.5-7.1

140M-D8E-C10 16 65,000 30,000140M-D8E-C16 16 65,000 30,000140M-C2E-C10 16 65,000140M-C2E-C16 16 30,000140M-C2E-B10 16 65,000 30,000140M-C2E-B16 16 65,000 30,000140M-C2E-B25 16 65,000 30,000140M-C2E-B40 16 65,000 25,000140M-C2E-B63 16 65,000140M-C2E-A__ 16 65,000 30,000

1492-J4 14…10

140M-F8E-C10 32 65,000 30,000

9.0

140M-F8E-C16 32 65,000 30,000140M-F8E-C20 32 65,000 30,000140M-F8E-C25 32 65,000 30,000140M-F8E-C32 32 65,000 30,000140M-D8E-C10 32 65,000 30,000140M-D8E-C16 32 65,000 30,000140M-D8E-C20 32 65,000140M-D8E-C25 32 30,000140M-D8E-B__ 32 65,000 30,000140M-C2E-C10 32 65,000140M-C2E-C16 32 30,000140M-C2E-B10 32 65,000 30,000140M-C2E-B16 32 65,000 30,000140M-C2E-B25 32 65,000 30,000140M-C2E-B40 32 65,000 25,000140M-C2E-B63 32 65,000140M-C2E-A__ 32 65,000 30,000

1492-J6 14…8

140M-F8E-C10 32 65,000 30,000

14.2

140M-F8E-C16 32 65,000 30,000140M-F8E-C20 32 65,000 30,000140M-F8E-C25 32 65,000 30,000140M-F8E-C32 32 65,000 30,000140M-D8E-C10 32 65,000 30,000140M-D8E-C16 32 65,000 30,000140M-D8E-C20 32 65,000140M-D8E-C25 32 30,000140M-D8E-B__ 32 65,000 30,000140M-C2E-C10 32 65,000140M-C2E-C16 32 30,000140M-C2E-B10 32 65,000 30,000140M-C2E-B16 32 65,000 30,000140M-C2E-B25 32 65,000 30,000140M-C2E-B40 32 65,000 25,000140M-C2E-B63 32 65,000140M-C2E-A__ 32 65,000 30,000

1492-J10 14…10

140M-H8P-C15 50 50,000 30,000

20.4140M-H8P-C30 50 50,000 30,000140M-H8P-C50 50 50,000 30,000140M-H8P-B__ 50 50,000 30,000

1492-J16 14…4 140M-H8P-___ 100 30,000 30,000 35.01492-J35 12…2 140M-H8P-___ 100 50,000 30,000 51.01492-J50 2…1/0 140M-H8P-___ 150 65,000 30,000 31.5

Bulletin 140M does not have ratings at this voltage. Note: Short-circuit current ratings testing not complete at time of printing. Consult www.ab.com for additions.

Page 11: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed
Page 12: SELECTION GUIDE BULLETIN 1492 - Rockwell Automation · 2019. 8. 15. · Bulletin 1492 Screw Connection Terminal Blocks 4 Visit our website: Preferred availability cat. nos. are printed

Publication1492-SG119A-EN-P - July 2008 Copyright ©2008 Rockwell Automation, Inc. All Rights Reserved. Printed in USA