Datasheet
Compact size and well known for itsproven reliability, the AR-Series utilizesthe hydraulic magnetic principle whichprovides precise operation and perform-ance even when exposed to extremelyhot and/or cold application environ-ments.
Features:
Blue housing
1-6 poles, 0.1 - 50 amps,
up to 277 VAC or 80 VDC,
Precise, temperature independant,operation
Choice of time delays, terminals andactuator colors.
Our Circuit Breakers are designed accordingto railway regulations:
- IEC 60077 - 1/2/3
- NF F62-001 - 1/2/3
- EN 45545-2 & NF F16-101/102(fire and toxic regulations)
Proven Reliability
7/27/2019 series_ar_v1.50_hr
2/9
Genaral tecnical dats
ElectricalMaximum Voltage 277VAC 50/60 Hz, 80VDCCurrent Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0.Other ratings available - consult ordering scheme.
Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme.Auxiliary Switch Rating SPDT; 10.1 A - 250VAC,
1.0 A-65VDC/0.5 A - 80 VDC,0.1A - 125VAC (with gold contacts).
Insulation Resistance Minimum: 100 Megohms at 500 VDCDielectric Strength 1500V 60 Hz for one minute between all electrically isolated terminals. AR-Series
rocker circuit breakers comply with the 8mm spacing & 3750V dielectric require-ments from hazardous voltage to operator accessible surfaces.
MechanicalEndurance 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.Trip Free All AR-Series Circuit Breakers will trip on overload, even when the actuator is
forcibly held in the ON position.Trip Indication The operating actuator moves positively to the OFF position when an overload
causes the circuit breaker to trip. When mid-trip handle is specified, the handlemoves to the mid position on electrical trip of the circuit breaker. When mid-triphandle with alarm switch is specified, the handle moves to the mid position &the alarm switch actuates when the circuit breaker is electrically tripped.
PhysicalNumber of Poles 1 - 6 Poles at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps.
Internal Circuit Configurations Series, (with or without auxiliary switch), Shunt with current or voltage trip coils,Dual Coil, Switch Only with or without auxiliary switch.
Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole)Standard Colors Housing - Blue; Actuator - White with dual legends.
EnvironmentalShock Withstands 100 Gs, 6ms, sawtooth while carrying rated current. Instantaneous
and ultra-short curves tested @ 90% of rated current.Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated
current. Instantaneous and ultrashort curves tested at 90% of rated current.Moisture Resistance Ten 24-hour cycles @ + 25C to +65C, 80-98% RH.56 days @ +85C, 85% RH.Salt Spray 90-95% RH @ 5% NaCl Solution, 96 hrs.Thermal Shock Five cycles @ -55C to +25C to +85C to +25C.
Operating Temperature -40 C to +85 C
2 http://www.morssmittrelais.com
General technical specifications - AR-Series
16.67
Time in
Milliseconds
t
12xMultipleof
RatedCurrent
rI
4.165 8.33
25x
Time Delay Curves
22, 24 & 26
(50 Amps Max.)
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
Time Delay Curves
42, 44 & 46
(50 Amps Max.) Time Delay Curves
42, 44 & 46
(50 Amps Max.)
5.0 20.0
Time in
Milliseconds
t
50 Hz 1/2 Cycle
Inrush Pulse Tolerance
Time Delay Curves
22, 24 & 26
(50 Amps Max.)
10.0
22x
10x
Multipleof
RatedCurrent
rI
Pulse Tolerance Curves
0.01
0.0010.01 0.1
1000
100
10
1
0.1
O
H
M
S
1 10 100
AMPERE RATING
RESISTANCE, IMPEDANCE VALUES
from Line to Load Terminals(Values Based on Series Trip Circuit Breaker)
CURRENT(AMPS)
0.10 - 5.0
5.1 - 20.0
15%
25%
TOLERANCE(%)
20.1 - 50.0 35%
Resistance, Impedance
7/27/2019 series_ar_v1.50_hr
3/9
3http://www.morssmittrelais.com
7Actuator
Color
8Aux/Alarm
Switch
3Current Rating
5Circuit
2Poles
6Actuator
10Mounting/
Barriers
AR 249
Terminal4
Frequency& Delay
1Series
A1 1 111
Agencyapproval
1610 3 3B
10 MOUNTING/BARRIERS
MOUNTING STYLE BARRIERSThreaded Inserts, 2 per pole
1 6-32 x 0.195 inches noA 6-32 X 0.195 inches yes2 ISO M3 x 5mm noB ISO M3 x 5mm yes
11 AGENCY APPROVAL
112 UL-Recognized, CSA, TUV to EN60077 and NF F62-001
9 TERMINAL9
110 Push-On 0.250 Tab (Q.C.)2 Screw 8-32 w/upturned lugs311 Screw 8-32 (Bus Type)4 Screw 10-32 w/upturned lugs511 Screw 10-32 (Bus Type)6 Screw 8-32 w/upturned lugs
and 30 bend7 Screw 8-32 (Bus Type) and
30 bend8 Screw 10-32 w/upturned lugs
and 30 bend9 Screw 10-32 (Bus Type) and
30 bendB Screw M5 w/upturned lugs
C Screw M4 w/upturned lugsE11 Screw M4 (Bus Type)F Screw M5 w/upturned lugs
and 30 bendG Screw M5 (Bus Type)
and 30 bendH Screw M5 (Bus Type)M11 M6 Threaded Stud
Q Push-In StudR Screw M4 w/upturned lugs
and 30 bendT11 Screw M4 (Bus Type)
and 30 bend
2 POLES
1 One2 Two
3 Three4 Four
5 Five6 Six
4 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only106 DC Instantaneous11 DC Ultra Short12 DC Short14 DC Medium16 DC Long206 50/60Hz Instantaneous21 50/60Hz Ultra Short22 50/60Hz Short024 50/60Hz Medium26 50/60Hz Long
30 DC, 50/60Hz Instantaneous31 DC, 50/60Hz Ultra Short32 DC, 50/60Hz Short34 DC, 50/60Hz Medium36 DC, 50/60Hz Long427 50/60Hz Short, Hi-Inrush447 50/60Hz Medium, Hi-Inrush467 50/60Hz Long, Hi-Inrush527 DC, Short,Hi-Inrush547 DC,Medium, Hi-Inrush567 DC, Long, Hi-Inrush
5 CIRCUIT
A2 Switch Only (No Coil)
B Series Trip (Current)C Series Trip (Voltage)D3 Shunt Trip (Current)
E3 Shunt Trip (Voltage)
H3,4
Dual Coil with Shunt TripVoltage Coil
6 ACTUATOR 1
A Handle, one per poleS Mid-Trip Handle, one per poleT Mid-Trip Handle, one per pole & Alarm Switch
1 SERIES
AR
8 AUXILIARY/ALARM SWITCH 5
0 w/o Aux Switch2 S.P.D.T., 0.110 Q.C. Term.3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.(Gold Contacts)
7 ACTUATOR COLOR & LEGEND
Actuator Color I-O Dual Legend Color White A 1 BlackBlack C 2 WhiteRed F 3 WhiteGreen H 4 WhiteBlue K 5 White
Yellow M 6 BlackGray P 7 BlackOrange R 8 Black
Ordering Scheme - AR-Series
3 CURRENT RATING (AMPERES)
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
210 0.100215 0.150220 0.200225 0.250
230 0.300235 0.350240 0.400245 0.450250 0.500255 0.550260 0.600265 0.650270 0.700275 0.750280 0.800
285 0.850290 0.900295 0.950410 1.000
512 1.250415 1.500517 1.750420 2.000522 2.250527 2.750430 3.000435 3.500440 4.000445 4.500450 5.000
455 5.500460 6.000465 6.500470 7.000
475 7.500480 8.000485 8.500490 9.000495 9.500610 10.000710 10.500611 11.000711 11.500612 12.000712 12.500
613 13.000614 14.000615 15.000616 16.000
617 17.000618 18.000620 20.000622 22.000624 24.000625 25.000630 30.0006358 35.0006408 40.0006458 45.0006508 50.000
A06 6 DCA12 12 DCA18 18 DCA24 24 DC
A32 32 DCA48 48 DCA65 65 DC
J06 6 AC
J12 12 ACJ18 18 ACJ24 24 ACJ48 48 AC
J65 65 ACK20 120 ACL40 240 AC
Notes:1 Actuator Code:A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.S: Handle moves to mid-position only upon electrical trip of the breaker. Available withcircuit codes B, C, D, E, and H.T: Handle moves to mid-position and alarm switch activates only upon electrical trip of thebreaker. Available with circuit codes B & C.
2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to aprotected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630.For 35 - 50 amps, select Current Code 650.
3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.4 Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require30VA minimum power to trip and are rated for intermittent duty only.
5 On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.6 Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10, 20 & 30.7 Available with Circuit Codes B & D only and up to 30 amps.8 Available up to two poles with AC or DC delays.9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G and H.10 Terminal Code 1: up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. TerminalCode M (M6 Threaded Stud) is supplied with lock and flat washers.12 Preliminary test results showed that the breakers comply to the EN60077 and NF F62-001.
Certificates for UL-Recognized and CSA are available on request. For the EN60077 andNF F62-001 the certificates will be available in short notice.
* Other values on request
7/27/2019 series_ar_v1.50_hr
4/9
4 http://www.morssmittrelais.comhttp://www.morssmittrelais.com
DELAY 100% 125% 135% 150% 200% 400% 600% 800% 1000% 1200%
10 No Trip May Trip --- .032 MAX .024 MAX .020 MAX .018 MAX .016 MAX .015 MAX .013 MAX
11 No Trip .013 - .125 --- .010 - .070 .008 - .032 .006 - .020 .005 - .020 .004 - .020 .004 - .020 .004 - .020
12 No Trip .500 - 6.50 --- .300 - 3.00 .130 - 1.20 .031 - .220 .011 - .120 .004 - .090 .004 - .060 .004 - .040
14 No Trip 2.00 - 60.0 --- 1.20 - 40.0 .600 - 20.0 .150 - 3.00 .030 - 1.30 .004 - .600 .004 - .100 .004 - .100
16 No Trip 45.0 - 345 --- 20.0 - 150 9.00 - 60.0 1.40 - 11.4 .150 - 5.80 .009 - 3.70 .005 - 1.70 .005 - .500
20 No Trip May Trip --- .040 MAX .035 MAX .030 MAX .025 MAX .020 MAX .017 MAX .015 MAX
21 No Trip .014 - .150 --- .011 - .095 .008 - .055 .006 - .035 .005 - .027 .005 - .021 .004 - .018 .004 - .017
TRIP 22 No Trip .700 - 12.0 --- .350 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .045 .004 - .040
TIME 24 No Trip 10.0 - 160 --- 6.00 - 60.0 2.20 - 20.0 .300 - 3.00 .050 - 1.30 .007 - .500 .005 - .060 .005 - .040
(SECONDS) 26 No Trip 50.0 - 700 --- 32.0 - 350 10.0 - 90.0 1.50 - 15.0 .500 - 7.00 .020 - 3.00 .006 - 2.00 .005 - 1.00
32 No Trip May Trip .400 - 8.00 .300 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .060 .004 - .040
34 No Trip May Trip 1.80 - 100 1.20 - 60.0 .600 - 20.0 .150 - 3.00 .030 - 1.30 .004 - .600 .004 - .110 .004 - .100
36 No Trip May Trip 35.0 - 520 20.0 - 350 9.00 - 90.0 1.40 - 15.0 .150 - 7.00 .009 - 3.70 .005 - 2.00 .004 - 1.00
42 No Trip .700 - 12.0 --- .400 - 6.00 .180 - 2.30 .050 - .600 .026 - .300 .018 - .200 .014 - .150 .012 - .130
44 No Trip 7.00 - 100 --- 3.00 - 50.0 1.10 - 18.0 .220 - 3.00 .120 - 1.70 .075 - 1.20 .050 - .850 .042 - .720
46 No Trip 50.0 - 700 --- 31.0 - 350 12.0 - 150 1.50 - 20.0 .700 - 10.0 .404 - 7.90 .260 - 6.50 .198 - 5.80
52 No Trip .500 - 6.50 --- .340 - 4.50 .180 - 2.30 .051 - .600 .030 - .320 .018 - .220 .014 - .200 .012 - .130
54 No Trip 1.50 - 50.0 --- .750 - 35.0 .350 - 18.0 .110 - 3.00 .070 - 1.70 .045 - 1.40 .039 - 1.30 .035 - 1.30
56 No Trip 45.0 - 345 --- 19.0 - 170 8.50 - 100 1.24 - 15.0 .410 - 9.00 .256 - 8.00 .210 - 5.50 .198 - 2.90
PERCENT OF RATED CURRENT
NOTES:Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve.Delay Curves 32,34,36: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.Delay Curves 10,20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.All Curves: Curve data shown represents breaker response at ambient temperature of 25C (77F) with no preloading. Breakers are mounted in standard wall-mount position.On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These val-ues are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitiveloads and transformer loads.
High Inrush AC
Short Medium Long
Time Delay Values - AR-Series
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 Hz - HI-INRUSHSHORT DELAYCURVE NO. 42
PERCENT OF RATED CURRENT
TRIPTIMEINSECONDS
150125
100 200 300 400 500 600 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 Hz - HI-INRUSHMEDIUM DELAYCURVE NO. 44
100 200 300 400 500 600 700
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
150
125
900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 Hz - HI-INRUSHLONG DELAYCURVE NO. 46
150125
100 200 300 400 500 600 700 800
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
AC
1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzINSTANTANEOUS
CURVE NO. 20
150
125
100 200 300 400 500 600 700 800 900
TRIPTIMEINSECONDS
PERCENT OF RATED CURRENT
Instantaneous Ultrashort Short
Medium Long
300 400 500 600 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT150
125
100 200
50/60 HzULTRASHORT DELAY
CURVE NO. 21
800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzSHORT DELAYCURVE NO. 22
TRIPTIMEINSECONDS
PERCENT OF RATED CURRENT150125
100 200 300 400 500 600 700
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzMEDIUM DELAYCURVE NO. 24
150
125
100 200 300 400 500 600
PERCENT OF RATED CURRENT
TRIPTIMEINSECONDS
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzLONG DELAYCURVE NO. 26
150
125
100 200 300 400 500 600
PERCENT OF RATED CURRENT
TRIPTIMEINSECONDS
7/27/2019 series_ar_v1.50_hr
5/9
5http://www.morssmittrelais.comhttp://www.morssmittrelais.com
DC
High Inrush DC
Short Medium Long
Medium Long
Instantaneous Ultrashort Short
1100 1200
10000
1000
100
10
1
.1
.01
.001
TRIPTIMEIN
SECOND
S
PERCENT OF RATED CURRENT
1000
D.C.
INSTANTANEOUSCURVE NO. 10
150
900800700600500400300200100
125
700 800 900 1000 1100 1200
TRIPTIMEIN
SECO
NDS
10000
1000
100
10
1
.1
.01
.001
PERCENT OF RATED CURRENT
100 200 300 400 500 600
D.C.ULTRASHORT DELAY
CURVE NO. 11
150
125
800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
PERCENT OF RATED CURRENT
D.C.SHORT DELAYCURVE NO. 12
125
100 200 300 400 500 600 700
TRIPTIMEIN
SECON
DS
150
Time Delay Values - AR-Series
800 900 1000 1100 1200
TRIPTIME
IN
SECONDS
10000
1000
100
10
1
.1
.01
.001
D.C. - HI - INRUSHSHORT DELAYCURVE NO. 52
PERCENT OF RATED CURRENT150125
100 200 300 400 500 600 700
D.C. - HI - INRUSHMEDIUM DELAYCURVE NO. 54
400 500 600 700 800 900 1000 1100 1200
TRIPTIM
EINSECONDS
10000
1000
100
10
1
.1
.01
.001
PERCENT OF RATED CURRENT125
150
100 200 300
D.C. - HI - INRUSHLONG DELAYCURVE NO. 56
400300200 1000 1200
10000
125
100 900
1
.1
.001
.01
1000
100
10
1100
PERCENT OF RATED CURRENT
TRIPTIMEINSECONDS
150
800700600500
600 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001100 200 300 400 500
125
150
TRIPTIM
EIN
SECONDS
PERCENT OF RATED CURRENT
D.C.MEDIUM DELAYCURVE NO. 14
900 1000 1100 1200100 200 300
1000
100
10
1
.1
.01
.001
150
125
400 500 600 700 800
D.C.
LONG DELAYCURVE NO. 16
TR
IPTIMEINSECONDS
PERCENT OF RATED CURRENT
AC/DC
Medium Long
Instantaneous Ultrashort Short
200 300 400 500 600 700 800 1000 1100
150
1200
1000
.01
.1
1
.001
10000
900100
PERCENT OF RATED CURRENT
TRIPTIMEIN
SEC
ONDS
D.C., 50/60 Hz
INSTANTANEOUS
CURVE NO. 30
10
100
135
D.C., 50/60 Hz
ULTRASHORT DELAY
CURVE NO. 31
1200
10000
PERCENT OF RATED CURRENT150
11001000800700600
.001
900500400300200100
1
.1
.01
1000
100
10
TRIPTIME
INSECONDS
.1
.01
.001
150135
100 200 300 400 500 600 700 800 900 1000 1100 1200
D.C., 50/60 HzSHORT DELAYCURVE NO. 32
10000
1000
100
10
1
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
600 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.001
.01
D.C., 50/60 HzMEDIUM DELAYCURVE NO. 34
PERCENT OF RATED CURRENT
TRIPTIMEINSECONDS
150135
100 200 300 400 500 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
TRIPTIMEINSECONDS
PERCENT OF RATED CURRENT
D.C., 50/60 HzLONG DELAYCURVE NO. 36
150135
100 200 300 400 500 600
7/27/2019 series_ar_v1.50_hr
6/9
6 http://www.morssmittrelais.com
Circuit & Terminal Diagrams - AR-Series
C
N0
SERIES TRIPAUX
SWITCH
CODE
CIRCUIT
CODECIRCUIT SCHEMATIC
ANSI
LINE
BC 0
NC
N0
SERIES TRIP WITH (3)AUXILIARY/ALARM SWITCH
STANDARD
AUX. SWITCH
LINE
BC
1234
C
LOAD
NC
ALARM SWITCH
H 0
LINE
LOAD
VOLTAGECOIL
0
CIRCUIT SCHEMATIC
CIRCUIT
CODE
AUX
SWITCH
CODE
LOAD
LINE
ANSI
SWITCH ONLY (NO COIL)
MAIN TERMINALS(SEE TABLE A)
A
LOAD
LINE
NO
STANDARDAUX. SWITCHTERMINALS
0
ALARMSWITCHTERMINALS& STD. AUX.SW. WITHVDE OR>30 AMPSOR AGENCYCODE "P"
DE
NO
C
NC
LOAD
SHUNT TRIP
LINE
SHUNT
C
NO
NC
LOADC
A
1234
LINE
SWITCH ONLY (NO COIL)WITH AUXILIARY SWITCH
LINE
NC
.520[13.21]
2 TERMINALS
3 TERMINALS
5 TERMINALS
LOAD
.205[5.21]
1.640 [41.66]
CIRCUIT BREAKER PROFILE
LOAD
.390[9.91]
DUAL COIL; SERIES TRIP CURRENT COIL,SHUNT TRIP VOLTAGE COIL
Form & Fit Drawings - AR-Series
All dimensions in inches and [mm]
All dimensions in inches and [mm]
7/27/2019 series_ar_v1.50_hr
7/9
7http://www.morssmittrelais.com
Form & Fit Drawings - AR-Series
+.002 [+.05]
-.000 [-.00]
.161 DIA [ 4.10]
PUSH-IN STUD
MATING HOLE
AUXILIARY/ALARM SWITCH TERMINAL DETAIL
SOLDER TYPETAB (Q.C.) TAB (Q.C.)
.125[3.18]
.058 DIA[1.47]
.139[3.53]
.344[8.74]
.110[2.79].050 DIA [1.27]
.093[2.36]
.250[6.35]
#8-32 & M4 THREADTERMINAL SCREW#10-32 & M5 THREADTERMINAL SCREW
#6-32 & M3 MOUNTINGHARDWARE
THREAD SIZE
TABLE ATIGHTENING TORQUE
SPECIFICATIONS
7-9 IN-LBS[0.8- 1.0 NM]12-15 IN-LBS[1.4-1.7 NM]
15-20 IN-LB[1.7-2.3 NM]
TORQUE
SCREW #8-32W/UPTURNED LUGS
.093 TAB (Q.C.)
.110 TAB (Q.C.)SOLDER TYPE
2.364 [60.05]
AUX.
SWITCH*
DEPTHBEHIND PANEL
2.032 [51.60]
2.000 [50.80]
2.207 [56.10]
2.095 [53.20]
2.189 [55.60]1.970 [50.00]
TABLE B
SHUNT&
DUAL COIL
MAIN
TERMINAL DESCRIPTION
TAB (Q.C.)
SCREW TYPE
TAB (Q.C.)
*AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS.WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONEAUX. SWITCH IS NORMALLY SUPPLIED.
PUSH-INSTUD
1.350 [34.29]
LINE(NETZ)
LOAD(LAST)
M6 STUD
1.936[49.17]
REF
DEPTH BEHINDPANEL
MIDTRIP
SEE TABLE B
1.640 [41.66]
ON
I
OFFO
1.560 [39.62]
.032 [.81] TYP
.220 [5.59] TYP SCREW TERM.WITH 30 BEND
30
ONE PER POLE
+.010-.000
[+.25][-.00].156 DIA [3.96]
2 PLCS TYPPER POLE
1.050 [26.67]
PER POLE
AA1, AB2, AB3
TOLERANCES .005 [.12]
UNLESS OTHERWISE SPECIFIED
AA2, AB4
AA3
AA4
.750 [19.05] TYP
PANEL CUTOUT DETAIL
1.660 [42.16]
.630 DIA [16.00]
TYPICAL - OPTIONAL"ON-OFF" LEGEND
2-POLE
.750 [19.05]
1.515 [38.48] MAX
.750 [19.05] TYP
4-POLE
MULTI-POLE HANDLE TIE KITSHIPPED BULK
3.015 [76.58] MAX
3-POLE
2.265 [57.53] MAX
.750 [19.05] TYP
OFF
ON
1.640 [41.66]TYP
LINESEE NOTE 3
.250[6.35] 2.032 [51.61]
2.000 [50.80]
1.660 [42.16] TYP
.590 DIA [14.99]
.170 [4.32]
2.000 [50.80] TYP
#6-32 [M3] THREAD X .195 [4.95] DEEP2 PLCS PER POLE
1-POLE
.610 [15.49]
60
.130 [3.30]
.690 [17.50]
SHORT HANDLE
TAB (Q.C.) TYPE TERMINALS INSERIES TRIP CIRCUIT
CONFIGURATION SHOWN.FOR OTHER CONFIGURATIONS,
SEE CIRCUIT AND TERMINALDIAGRAMS.
.755 [19.18] MAX
LOAD
TAB (Q.C.) TYPE
SCREW TYPE
1.560 [39.62] TYP
All dimensions in inches and [mm]
7/27/2019 series_ar_v1.50_hr
8/9
8
ComDocSolutions-2004
Proven ReliabilityDS/GB AR-Series 1.50 / 04-04
France USA
Your local distributor:
For further information please contact:
The Netherlands
MORS SMITT TECHNOLOGIES INC.
50 North New York AvenueHuntington, NY, 11743USATel. +1 (631) 271-8858Fax +1 (631) [email protected]
http://www.morssmittrelais.com
MS RELAIS SAS
Tour Rosny 2Avenue du Gnral de GaulleF - 93118 Rosny-sous-Bois CedexFranceTel. +33 (0)1 48 12 14 40Fax +33 (0)1 48 55 90 [email protected]
http://www.morssmittrelais.com
NIEAF-SMITT BV
Vrieslantlaan 6NL - 3526 AA, UtrechtThe NetherlandsTel. +31 (0)30 288 13 11Fax +31 (0)30 289 88 [email protected]
http://www.nieaf-smitt.nl/railway
7/27/2019 series_ar_v1.50_hr
9/9
Aust ral ian Dist ri bu to r
Relay Monitoring Systems Pty Ltd6 Anzed CourtMulgrave, Victoria, 3170, Australia
Phone: +61 3 8544 1200Fax: +61 3 8544 1201Email: [email protected]: www.rmspl.com.au
mailto:[email protected]://www.rmspl.com.au/http://www.rmspl.com.au/mailto:[email protected]