  • 7/27/2019 series_ar_v1.50_hr

    1/9

    Datasheet

    Compact size and well known for itsproven reliability, the AR-Series utilizesthe hydraulic magnetic principle whichprovides precise operation and perform-ance even when exposed to extremelyhot and/or cold application environ-ments.

    Features:

    Blue housing

    1-6 poles, 0.1 - 50 amps,

    up to 277 VAC or 80 VDC,

    Precise, temperature independant,operation

    Choice of time delays, terminals andactuator colors.

    Our Circuit Breakers are designed accordingto railway regulations:

    - IEC 60077 - 1/2/3

    - NF F62-001 - 1/2/3

    - EN 45545-2 & NF F16-101/102(fire and toxic regulations)

    Proven Reliability

  • 7/27/2019 series_ar_v1.50_hr

    2/9

    Genaral tecnical dats

    ElectricalMaximum Voltage 277VAC 50/60 Hz, 80VDCCurrent Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50,

    10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0.Other ratings available - consult ordering scheme.

    Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme.Auxiliary Switch Rating SPDT; 10.1 A - 250VAC,

    1.0 A-65VDC/0.5 A - 80 VDC,0.1A - 125VAC (with gold contacts).

    Insulation Resistance Minimum: 100 Megohms at 500 VDCDielectric Strength 1500V 60 Hz for one minute between all electrically isolated terminals. AR-Series

    rocker circuit breakers comply with the 8mm spacing & 3750V dielectric require-ments from hazardous voltage to operator accessible surfaces.

    MechanicalEndurance 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.Trip Free All AR-Series Circuit Breakers will trip on overload, even when the actuator is

    forcibly held in the ON position.Trip Indication The operating actuator moves positively to the OFF position when an overload

    causes the circuit breaker to trip. When mid-trip handle is specified, the handlemoves to the mid position on electrical trip of the circuit breaker. When mid-triphandle with alarm switch is specified, the handle moves to the mid position &the alarm switch actuates when the circuit breaker is electrically tripped.

    PhysicalNumber of Poles 1 - 6 Poles at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps.

    Internal Circuit Configurations Series, (with or without auxiliary switch), Shunt with current or voltage trip coils,Dual Coil, Switch Only with or without auxiliary switch.

    Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole)Standard Colors Housing - Blue; Actuator - White with dual legends.

    EnvironmentalShock Withstands 100 Gs, 6ms, sawtooth while carrying rated current. Instantaneous

    and ultra-short curves tested @ 90% of rated current.Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated

    current. Instantaneous and ultrashort curves tested at 90% of rated current.Moisture Resistance Ten 24-hour cycles @ + 25C to +65C, 80-98% RH.56 days @ +85C, 85% RH.Salt Spray 90-95% RH @ 5% NaCl Solution, 96 hrs.Thermal Shock Five cycles @ -55C to +25C to +85C to +25C.

    Operating Temperature -40 C to +85 C

    2 http://www.morssmittrelais.com

    General technical specifications - AR-Series

    16.67

    Time in

    Milliseconds

    t

    12xMultipleof

    RatedCurrent

    rI

    4.165 8.33

    25x

    Time Delay Curves

    22, 24 & 26

    (50 Amps Max.)

    60 Hz 1/2 Cycle

    Inrush Pulse Tolerance

    Time Delay Curves

    42, 44 & 46

    (50 Amps Max.) Time Delay Curves

    42, 44 & 46

    (50 Amps Max.)

    5.0 20.0

    Time in

    Milliseconds

    t

    50 Hz 1/2 Cycle

    Inrush Pulse Tolerance

    Time Delay Curves

    22, 24 & 26

    (50 Amps Max.)

    10.0

    22x

    10x

    Multipleof

    RatedCurrent

    rI

    Pulse Tolerance Curves

    0.01

    0.0010.01 0.1

    1000

    100

    10

    1

    0.1

    O

    H

    M

    S

    1 10 100

    AMPERE RATING

    RESISTANCE, IMPEDANCE VALUES

    from Line to Load Terminals(Values Based on Series Trip Circuit Breaker)

    CURRENT(AMPS)

    0.10 - 5.0

    5.1 - 20.0

    15%

    25%

    TOLERANCE(%)

    20.1 - 50.0 35%

    Resistance, Impedance

  • 7/27/2019 series_ar_v1.50_hr

    3/9

    3http://www.morssmittrelais.com

    7Actuator

    Color

    8Aux/Alarm

    Switch

    3Current Rating

    5Circuit

    2Poles

    6Actuator

    10Mounting/

    Barriers

    AR 249

    Terminal4

    Frequency& Delay

    1Series

    A1 1 111

    Agencyapproval

    1610 3 3B

    10 MOUNTING/BARRIERS

    MOUNTING STYLE BARRIERSThreaded Inserts, 2 per pole

    1 6-32 x 0.195 inches noA 6-32 X 0.195 inches yes2 ISO M3 x 5mm noB ISO M3 x 5mm yes

    11 AGENCY APPROVAL

    112 UL-Recognized, CSA, TUV to EN60077 and NF F62-001

    9 TERMINAL9

    110 Push-On 0.250 Tab (Q.C.)2 Screw 8-32 w/upturned lugs311 Screw 8-32 (Bus Type)4 Screw 10-32 w/upturned lugs511 Screw 10-32 (Bus Type)6 Screw 8-32 w/upturned lugs

    and 30 bend7 Screw 8-32 (Bus Type) and

    30 bend8 Screw 10-32 w/upturned lugs

    and 30 bend9 Screw 10-32 (Bus Type) and

    30 bendB Screw M5 w/upturned lugs

    C Screw M4 w/upturned lugsE11 Screw M4 (Bus Type)F Screw M5 w/upturned lugs

    and 30 bendG Screw M5 (Bus Type)

    and 30 bendH Screw M5 (Bus Type)M11 M6 Threaded Stud

    Q Push-In StudR Screw M4 w/upturned lugs

    and 30 bendT11 Screw M4 (Bus Type)

    and 30 bend

    2 POLES

    1 One2 Two

    3 Three4 Four

    5 Five6 Six

    4 FREQUENCY & DELAY

    03 DC 50/60Hz, Switch Only106 DC Instantaneous11 DC Ultra Short12 DC Short14 DC Medium16 DC Long206 50/60Hz Instantaneous21 50/60Hz Ultra Short22 50/60Hz Short024 50/60Hz Medium26 50/60Hz Long

    30 DC, 50/60Hz Instantaneous31 DC, 50/60Hz Ultra Short32 DC, 50/60Hz Short34 DC, 50/60Hz Medium36 DC, 50/60Hz Long427 50/60Hz Short, Hi-Inrush447 50/60Hz Medium, Hi-Inrush467 50/60Hz Long, Hi-Inrush527 DC, Short,Hi-Inrush547 DC,Medium, Hi-Inrush567 DC, Long, Hi-Inrush

    5 CIRCUIT

    A2 Switch Only (No Coil)

    B Series Trip (Current)C Series Trip (Voltage)D3 Shunt Trip (Current)

    E3 Shunt Trip (Voltage)

    H3,4

    Dual Coil with Shunt TripVoltage Coil

    6 ACTUATOR 1

    A Handle, one per poleS Mid-Trip Handle, one per poleT Mid-Trip Handle, one per pole & Alarm Switch

    1 SERIES

    AR

    8 AUXILIARY/ALARM SWITCH 5

    0 w/o Aux Switch2 S.P.D.T., 0.110 Q.C. Term.3 S.P.D.T., 0.139 Solder Lug

    4 S.P.D.T., 0.110 Q.C. Term.(Gold Contacts)

    7 ACTUATOR COLOR & LEGEND

    Actuator Color I-O Dual Legend Color White A 1 BlackBlack C 2 WhiteRed F 3 WhiteGreen H 4 WhiteBlue K 5 White

    Yellow M 6 BlackGray P 7 BlackOrange R 8 Black

    Ordering Scheme - AR-Series

    3 CURRENT RATING (AMPERES)

    OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6

    210 0.100215 0.150220 0.200225 0.250

    230 0.300235 0.350240 0.400245 0.450250 0.500255 0.550260 0.600265 0.650270 0.700275 0.750280 0.800

    285 0.850290 0.900295 0.950410 1.000

    512 1.250415 1.500517 1.750420 2.000522 2.250527 2.750430 3.000435 3.500440 4.000445 4.500450 5.000

    455 5.500460 6.000465 6.500470 7.000

    475 7.500480 8.000485 8.500490 9.000495 9.500610 10.000710 10.500611 11.000711 11.500612 12.000712 12.500

    613 13.000614 14.000615 15.000616 16.000

    617 17.000618 18.000620 20.000622 22.000624 24.000625 25.000630 30.0006358 35.0006408 40.0006458 45.0006508 50.000

    A06 6 DCA12 12 DCA18 18 DCA24 24 DC

    A32 32 DCA48 48 DCA65 65 DC

    J06 6 AC

    J12 12 ACJ18 18 ACJ24 24 ACJ48 48 AC

    J65 65 ACK20 120 ACL40 240 AC

    Notes:1 Actuator Code:A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.S: Handle moves to mid-position only upon electrical trip of the breaker. Available withcircuit codes B, C, D, E, and H.T: Handle moves to mid-position and alarm switch activates only upon electrical trip of thebreaker. Available with circuit codes B & C.

    2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to aprotected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630.For 35 - 50 amps, select Current Code 650.

    3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.4 Consult factory for available Dual Coil options, as special catalog number is required. With

    Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require30VA minimum power to trip and are rated for intermittent duty only.

    5 On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.6 Separate pole type voltage coils not rated for continuous duty. Available only with delay

    codes 10, 20 & 30.7 Available with Circuit Codes B & D only and up to 30 amps.8 Available up to two poles with AC or DC delays.9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps

    are only available with Terminal Codes 5, 9, G and H.10 Terminal Code 1: up to 30 amps, but not recommended over 20 amps.

    11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. TerminalCode M (M6 Threaded Stud) is supplied with lock and flat washers.12 Preliminary test results showed that the breakers comply to the EN60077 and NF F62-001.

    Certificates for UL-Recognized and CSA are available on request. For the EN60077 andNF F62-001 the certificates will be available in short notice.

    * Other values on request

  • 7/27/2019 series_ar_v1.50_hr

    4/9

    4 http://www.morssmittrelais.comhttp://www.morssmittrelais.com

    DELAY 100% 125% 135% 150% 200% 400% 600% 800% 1000% 1200%

    10 No Trip May Trip --- .032 MAX .024 MAX .020 MAX .018 MAX .016 MAX .015 MAX .013 MAX

    11 No Trip .013 - .125 --- .010 - .070 .008 - .032 .006 - .020 .005 - .020 .004 - .020 .004 - .020 .004 - .020

    12 No Trip .500 - 6.50 --- .300 - 3.00 .130 - 1.20 .031 - .220 .011 - .120 .004 - .090 .004 - .060 .004 - .040

    14 No Trip 2.00 - 60.0 --- 1.20 - 40.0 .600 - 20.0 .150 - 3.00 .030 - 1.30 .004 - .600 .004 - .100 .004 - .100

    16 No Trip 45.0 - 345 --- 20.0 - 150 9.00 - 60.0 1.40 - 11.4 .150 - 5.80 .009 - 3.70 .005 - 1.70 .005 - .500

    20 No Trip May Trip --- .040 MAX .035 MAX .030 MAX .025 MAX .020 MAX .017 MAX .015 MAX

    21 No Trip .014 - .150 --- .011 - .095 .008 - .055 .006 - .035 .005 - .027 .005 - .021 .004 - .018 .004 - .017

    TRIP 22 No Trip .700 - 12.0 --- .350 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .045 .004 - .040

    TIME 24 No Trip 10.0 - 160 --- 6.00 - 60.0 2.20 - 20.0 .300 - 3.00 .050 - 1.30 .007 - .500 .005 - .060 .005 - .040

    (SECONDS) 26 No Trip 50.0 - 700 --- 32.0 - 350 10.0 - 90.0 1.50 - 15.0 .500 - 7.00 .020 - 3.00 .006 - 2.00 .005 - 1.00

    32 No Trip May Trip .400 - 8.00 .300 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .060 .004 - .040

    34 No Trip May Trip 1.80 - 100 1.20 - 60.0 .600 - 20.0 .150 - 3.00 .030 - 1.30 .004 - .600 .004 - .110 .004 - .100

    36 No Trip May Trip 35.0 - 520 20.0 - 350 9.00 - 90.0 1.40 - 15.0 .150 - 7.00 .009 - 3.70 .005 - 2.00 .004 - 1.00

    42 No Trip .700 - 12.0 --- .400 - 6.00 .180 - 2.30 .050 - .600 .026 - .300 .018 - .200 .014 - .150 .012 - .130

    44 No Trip 7.00 - 100 --- 3.00 - 50.0 1.10 - 18.0 .220 - 3.00 .120 - 1.70 .075 - 1.20 .050 - .850 .042 - .720

    46 No Trip 50.0 - 700 --- 31.0 - 350 12.0 - 150 1.50 - 20.0 .700 - 10.0 .404 - 7.90 .260 - 6.50 .198 - 5.80

    52 No Trip .500 - 6.50 --- .340 - 4.50 .180 - 2.30 .051 - .600 .030 - .320 .018 - .220 .014 - .200 .012 - .130

    54 No Trip 1.50 - 50.0 --- .750 - 35.0 .350 - 18.0 .110 - 3.00 .070 - 1.70 .045 - 1.40 .039 - 1.30 .035 - 1.30

    56 No Trip 45.0 - 345 --- 19.0 - 170 8.50 - 100 1.24 - 15.0 .410 - 9.00 .256 - 8.00 .210 - 5.50 .198 - 2.90

    PERCENT OF RATED CURRENT

    NOTES:Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve.Delay Curves 32,34,36: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.Delay Curves 10,20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.All Curves: Curve data shown represents breaker response at ambient temperature of 25C (77F) with no preloading. Breakers are mounted in standard wall-mount position.On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These val-ues are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitiveloads and transformer loads.

    High Inrush AC

    Short Medium Long

    Time Delay Values - AR-Series

    700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 Hz - HI-INRUSHSHORT DELAYCURVE NO. 42

    PERCENT OF RATED CURRENT

    TRIPTIMEINSECONDS

    150125

    100 200 300 400 500 600 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 Hz - HI-INRUSHMEDIUM DELAYCURVE NO. 44

    100 200 300 400 500 600 700

    PERCENT OF RATED CURRENT

    TRIPTIMEIN

    SECONDS

    150

    125

    900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 Hz - HI-INRUSHLONG DELAYCURVE NO. 46

    150125

    100 200 300 400 500 600 700 800

    TRIPTIMEIN

    SECONDS

    PERCENT OF RATED CURRENT

    AC

    1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 HzINSTANTANEOUS

    CURVE NO. 20

    150

    125

    100 200 300 400 500 600 700 800 900

    TRIPTIMEINSECONDS

    PERCENT OF RATED CURRENT

    Instantaneous Ultrashort Short

    Medium Long

    300 400 500 600 700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    TRIPTIMEIN

    SECONDS

    PERCENT OF RATED CURRENT150

    125

    100 200

    50/60 HzULTRASHORT DELAY

    CURVE NO. 21

    800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 HzSHORT DELAYCURVE NO. 22

    TRIPTIMEINSECONDS

    PERCENT OF RATED CURRENT150125

    100 200 300 400 500 600 700

    700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 HzMEDIUM DELAYCURVE NO. 24

    150

    125

    100 200 300 400 500 600

    PERCENT OF RATED CURRENT

    TRIPTIMEINSECONDS

    700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    50/60 HzLONG DELAYCURVE NO. 26

    150

    125

    100 200 300 400 500 600

    PERCENT OF RATED CURRENT

    TRIPTIMEINSECONDS

  • 7/27/2019 series_ar_v1.50_hr

    5/9

    5http://www.morssmittrelais.comhttp://www.morssmittrelais.com

    DC

    High Inrush DC

    Short Medium Long

    Medium Long

    Instantaneous Ultrashort Short

    1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    TRIPTIMEIN

    SECOND

    S

    PERCENT OF RATED CURRENT

    1000

    D.C.

    INSTANTANEOUSCURVE NO. 10

    150

    900800700600500400300200100

    125

    700 800 900 1000 1100 1200

    TRIPTIMEIN

    SECO

    NDS

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    PERCENT OF RATED CURRENT

    100 200 300 400 500 600

    D.C.ULTRASHORT DELAY

    CURVE NO. 11

    150

    125

    800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    PERCENT OF RATED CURRENT

    D.C.SHORT DELAYCURVE NO. 12

    125

    100 200 300 400 500 600 700

    TRIPTIMEIN

    SECON

    DS

    150

    Time Delay Values - AR-Series

    800 900 1000 1100 1200

    TRIPTIME

    IN

    SECONDS

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    D.C. - HI - INRUSHSHORT DELAYCURVE NO. 52

    PERCENT OF RATED CURRENT150125

    100 200 300 400 500 600 700

    D.C. - HI - INRUSHMEDIUM DELAYCURVE NO. 54

    400 500 600 700 800 900 1000 1100 1200

    TRIPTIM

    EINSECONDS

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    PERCENT OF RATED CURRENT125

    150

    100 200 300

    D.C. - HI - INRUSHLONG DELAYCURVE NO. 56

    400300200 1000 1200

    10000

    125

    100 900

    1

    .1

    .001

    .01

    1000

    100

    10

    1100

    PERCENT OF RATED CURRENT

    TRIPTIMEINSECONDS

    150

    800700600500

    600 700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001100 200 300 400 500

    125

    150

    TRIPTIM

    EIN

    SECONDS

    PERCENT OF RATED CURRENT

    D.C.MEDIUM DELAYCURVE NO. 14

    900 1000 1100 1200100 200 300

    1000

    100

    10

    1

    .1

    .01

    .001

    150

    125

    400 500 600 700 800

    D.C.

    LONG DELAYCURVE NO. 16

    TR

    IPTIMEINSECONDS

    PERCENT OF RATED CURRENT

    AC/DC

    Medium Long

    Instantaneous Ultrashort Short

    200 300 400 500 600 700 800 1000 1100

    150

    1200

    1000

    .01

    .1

    1

    .001

    10000

    900100

    PERCENT OF RATED CURRENT

    TRIPTIMEIN

    SEC

    ONDS

    D.C., 50/60 Hz

    INSTANTANEOUS

    CURVE NO. 30

    10

    100

    135

    D.C., 50/60 Hz

    ULTRASHORT DELAY

    CURVE NO. 31

    1200

    10000

    PERCENT OF RATED CURRENT150

    11001000800700600

    .001

    900500400300200100

    1

    .1

    .01

    1000

    100

    10

    TRIPTIME

    INSECONDS

    .1

    .01

    .001

    150135

    100 200 300 400 500 600 700 800 900 1000 1100 1200

    D.C., 50/60 HzSHORT DELAYCURVE NO. 32

    10000

    1000

    100

    10

    1

    TRIPTIMEIN

    SECONDS

    PERCENT OF RATED CURRENT

    600 700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .001

    .01

    D.C., 50/60 HzMEDIUM DELAYCURVE NO. 34

    PERCENT OF RATED CURRENT

    TRIPTIMEINSECONDS

    150135

    100 200 300 400 500 700 800 900 1000 1100 1200

    10000

    1000

    100

    10

    1

    .1

    .01

    .001

    TRIPTIMEINSECONDS

    PERCENT OF RATED CURRENT

    D.C., 50/60 HzLONG DELAYCURVE NO. 36

    150135

    100 200 300 400 500 600

  • 7/27/2019 series_ar_v1.50_hr

    6/9

    6 http://www.morssmittrelais.com

    Circuit & Terminal Diagrams - AR-Series

    C

    N0

    SERIES TRIPAUX

    SWITCH

    CODE

    CIRCUIT

    CODECIRCUIT SCHEMATIC

    ANSI

    LINE

    BC 0

    NC

    N0

    SERIES TRIP WITH (3)AUXILIARY/ALARM SWITCH

    STANDARD

    AUX. SWITCH

    LINE

    BC

    1234

    C

    LOAD

    NC

    ALARM SWITCH

    H 0

    LINE

    LOAD

    VOLTAGECOIL

    0

    CIRCUIT SCHEMATIC

    CIRCUIT

    CODE

    AUX

    SWITCH

    CODE

    LOAD

    LINE

    ANSI

    SWITCH ONLY (NO COIL)

    MAIN TERMINALS(SEE TABLE A)

    A

    LOAD

    LINE

    NO

    STANDARDAUX. SWITCHTERMINALS

    0

    ALARMSWITCHTERMINALS& STD. AUX.SW. WITHVDE OR>30 AMPSOR AGENCYCODE "P"

    DE

    NO

    C

    NC

    LOAD

    SHUNT TRIP

    LINE

    SHUNT

    C

    NO

    NC

    LOADC

    A

    1234

    LINE

    SWITCH ONLY (NO COIL)WITH AUXILIARY SWITCH

    LINE

    NC

    .520[13.21]

    2 TERMINALS

    3 TERMINALS

    5 TERMINALS

    LOAD

    .205[5.21]

    1.640 [41.66]

    CIRCUIT BREAKER PROFILE

    LOAD

    .390[9.91]

    DUAL COIL; SERIES TRIP CURRENT COIL,SHUNT TRIP VOLTAGE COIL

    Form & Fit Drawings - AR-Series

    All dimensions in inches and [mm]

    All dimensions in inches and [mm]

  • 7/27/2019 series_ar_v1.50_hr

    7/9

    7http://www.morssmittrelais.com

    Form & Fit Drawings - AR-Series

    +.002 [+.05]

    -.000 [-.00]

    .161 DIA [ 4.10]

    PUSH-IN STUD

    MATING HOLE

    AUXILIARY/ALARM SWITCH TERMINAL DETAIL

    SOLDER TYPETAB (Q.C.) TAB (Q.C.)

    .125[3.18]

    .058 DIA[1.47]

    .139[3.53]

    .344[8.74]

    .110[2.79].050 DIA [1.27]

    .093[2.36]

    .250[6.35]

    #8-32 & M4 THREADTERMINAL SCREW#10-32 & M5 THREADTERMINAL SCREW

    #6-32 & M3 MOUNTINGHARDWARE

    THREAD SIZE

    TABLE ATIGHTENING TORQUE

    SPECIFICATIONS

    7-9 IN-LBS[0.8- 1.0 NM]12-15 IN-LBS[1.4-1.7 NM]

    15-20 IN-LB[1.7-2.3 NM]

    TORQUE

    SCREW #8-32W/UPTURNED LUGS

    .093 TAB (Q.C.)

    .110 TAB (Q.C.)SOLDER TYPE

    2.364 [60.05]

    AUX.

    SWITCH*

    DEPTHBEHIND PANEL

    2.032 [51.60]

    2.000 [50.80]

    2.207 [56.10]

    2.095 [53.20]

    2.189 [55.60]1.970 [50.00]

    TABLE B

    SHUNT&

    DUAL COIL

    MAIN

    TERMINAL DESCRIPTION

    TAB (Q.C.)

    SCREW TYPE

    TAB (Q.C.)

    *AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS.WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONEAUX. SWITCH IS NORMALLY SUPPLIED.

    PUSH-INSTUD

    1.350 [34.29]

    LINE(NETZ)

    LOAD(LAST)

    M6 STUD

    1.936[49.17]

    REF

    DEPTH BEHINDPANEL

    MIDTRIP

    SEE TABLE B

    1.640 [41.66]

    ON

    I

    OFFO

    1.560 [39.62]

    .032 [.81] TYP

    .220 [5.59] TYP SCREW TERM.WITH 30 BEND

    30

    ONE PER POLE

    +.010-.000

    [+.25][-.00].156 DIA [3.96]

    2 PLCS TYPPER POLE

    1.050 [26.67]

    PER POLE

    AA1, AB2, AB3

    TOLERANCES .005 [.12]

    UNLESS OTHERWISE SPECIFIED

    AA2, AB4

    AA3

    AA4

    .750 [19.05] TYP

    PANEL CUTOUT DETAIL

    1.660 [42.16]

    .630 DIA [16.00]

    TYPICAL - OPTIONAL"ON-OFF" LEGEND

    2-POLE

    .750 [19.05]

    1.515 [38.48] MAX

    .750 [19.05] TYP

    4-POLE

    MULTI-POLE HANDLE TIE KITSHIPPED BULK

    3.015 [76.58] MAX

    3-POLE

    2.265 [57.53] MAX

    .750 [19.05] TYP

    OFF

    ON

    1.640 [41.66]TYP

    LINESEE NOTE 3

    .250[6.35] 2.032 [51.61]

    2.000 [50.80]

    1.660 [42.16] TYP

    .590 DIA [14.99]

    .170 [4.32]

    2.000 [50.80] TYP

    #6-32 [M3] THREAD X .195 [4.95] DEEP2 PLCS PER POLE

    1-POLE

    .610 [15.49]

    60

    .130 [3.30]

    .690 [17.50]

    SHORT HANDLE

    TAB (Q.C.) TYPE TERMINALS INSERIES TRIP CIRCUIT

    CONFIGURATION SHOWN.FOR OTHER CONFIGURATIONS,

    SEE CIRCUIT AND TERMINALDIAGRAMS.

    .755 [19.18] MAX

    LOAD

    TAB (Q.C.) TYPE

    SCREW TYPE

    1.560 [39.62] TYP

    All dimensions in inches and [mm]

  • 7/27/2019 series_ar_v1.50_hr

    8/9

    8

    ComDocSolutions-2004

    Proven ReliabilityDS/GB AR-Series 1.50 / 04-04

    France USA

    Your local distributor:

    For further information please contact:

    The Netherlands

    MORS SMITT TECHNOLOGIES INC.

    50 North New York AvenueHuntington, NY, 11743USATel. +1 (631) 271-8858Fax +1 (631) [email protected]

    http://www.morssmittrelais.com

    MS RELAIS SAS

    Tour Rosny 2Avenue du Gnral de GaulleF - 93118 Rosny-sous-Bois CedexFranceTel. +33 (0)1 48 12 14 40Fax +33 (0)1 48 55 90 [email protected]

    http://www.morssmittrelais.com

    NIEAF-SMITT BV

    Vrieslantlaan 6NL - 3526 AA, UtrechtThe NetherlandsTel. +31 (0)30 288 13 11Fax +31 (0)30 289 88 [email protected]

    http://www.nieaf-smitt.nl/railway

  • 7/27/2019 series_ar_v1.50_hr

    9/9

    Aust ral ian Dist ri bu to r

    Relay Monitoring Systems Pty Ltd6 Anzed CourtMulgrave, Victoria, 3170, Australia

    Phone: +61 3 8544 1200Fax: +61 3 8544 1201Email: [email protected]: www.rmspl.com.au

    mailto:[email protected]://www.rmspl.com.au/http://www.rmspl.com.au/mailto:[email protected]