7
SIGNAGE & WAYFINDING PROGRAM HOTEL X Schematic Design Entro Project Number 1116 D Issued For Review August 18, 2014 (Primary Site ID Review) C Issued For Review August 14, 2014 (Primary Site ID Review) B Issued For Review August 06, 2014 (Primary Site ID Review) A Issued For Review July 31, 2014 (Primary Site ID Review)

SIGNAGE & WAYFINDING PROGRAM HOTEL X

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SIGNAGE & WAYFINDING PROGRAM HOTEL X

SIGNAGE & WAYFINDING PROGRAM

HOTEL X

Schematic Design Entro Project Number 1116

D Issued For Review August 18, 2014 (Primary Site ID Review) C Issued For Review August 14, 2014 (Primary Site ID Review) B Issued For Review August 06, 2014 (Primary Site ID Review) A Issued For Review July 31, 2014 (Primary Site ID Review)

Page 2: SIGNAGE & WAYFINDING PROGRAM HOTEL X

FROM PRINCES GATES

Secondary Site ID – Freestanding Pylon (Illuminated)

Secondary Entrance ID Inclusion TBD)

Parking ID (Illuminated)

Loading Dock ID

Secondary Entrance ID (Inclusion TBD)

Secondary Entrance ID (Illuminated)

Vehicular Directional (TBD - possibly incorporated with Entry Pylon)

Entry Pylon (Illuminated)

Entry Pylon (Illuminated)

Vehicular Directional (TBD - possibly incorporated with Entry Pylon)

True

North

A B

A B

B

B

Secondary Entrance ID Inclusion TBD)

Secondary Entrance ID Inclusion TBD)

Entrance ID above doors

B

B

B

B

Primary Site ID – Freestanding Pylon (Illuminated, with LED board)

NOTE: exact placement TBD based on landscaping.

Main Entrnace ID above canopy (Illuminated)

Parking Valet Only Entrance Sign

B

B

A

BA BA

A

Pedestrian Directional

B

A

Pedestrian Directional

B

A

LOADING DOCK

PARKING ENTRANCE

MAIN ENTRANCE

VALET PARKING

ENTRANCE

STANLEY BARRACKS

GARDEN

GET UPDATED PLAN

Primary Site ID Review – Site Plan Signage and Wayfinding Program – Hotel X // Aug 18, 2014 // Page 2

Page 3: SIGNAGE & WAYFINDING PROGRAM HOTEL X

True

North

Scale = 1:100

0 1 2 3 4 5 10m

A B

Primary Site ID – Freestanding Pylon (Illuminated, with LED board)

NOTE: exact placement TBD based on landscaping.

Area dedicated to future road widening (City Property)

GET UPDATED PLAN/ ADD DIMENSIONS

Primary Site ID Review – Site Plan Signage and Wayfinding Program – Hotel X // Aug 18, 2014 // Page 3

Page 4: SIGNAGE & WAYFINDING PROGRAM HOTEL X

10 m

9 m

8 m

7 m

3,810 mm (12' 6")

(full colour LED)

1 m

2 m

3 m

4 m

5 m

6 m

Sign to include:

t�)NTERNALLY�ILLUMINATED��PAINTED�ALUM�SIGN�FACE� with incised/infilled or push-thru graphics

t�!BOVE�GRADE�CONCRETE�PEDESTAL�AS�NOTED��/PT�

t�3TRUCTURAL�CONCRETE�SIGN�BASE�FOUNDATION

t�%LECTRICAL�HOOK UP��RUN���CONDUITS��ONE�FOR� 20 AMP - 120 Volt, and one for Data Cat 5

t�0ERMIT�APPLICATION�FEES��0�%NG�STAMP

NOTE: ONLY APPROXIMATE SIZE IS SHOWN HERE. SIGN DESIGN CONCEPTS ON FOLLOWING PAGES HAVE A SIGN FACE OF APPROXIMATELY 20 SQ METRES.

�ABOVE�GRADE�CONCRETE�PEDESTAL

6,2

00 m

m (

20' 4

")

5,1

82 m

m (

17' 0

")

750 m

m (

2' 6

")

Primary Site ID – Freestanding Pylon Scale 1:25

NOTE: Variance required Approximate sign cost = $80,000 Sign face = approx. 20 sq m

Primary Site ID Review – Sign Size Options Signage and Wayfinding Program – Hotel X // Aug 18, 2014 // Page 4

Page 5: SIGNAGE & WAYFINDING PROGRAM HOTEL X

VIEW DRIVING EAST ON LAKESHORE BLVD. W. (OPTION 1 – ESTIMATED SIZE SHOWN)

VIEW DRIVING WEST ON LAKESHORE BLVD. W. (OPTION 1 – ESTIMATED SIZE SHOWN)

Primary Site ID Review – Views Signage and Wayfinding Program – Hotel X // Aug 6, 2014 // Page 5

Page 6: SIGNAGE & WAYFINDING PROGRAM HOTEL X

OPTION 1

10 m

Logo and address could possible be push through letters edge-lit9 m

± 2,500 mm (8' 2") ± 460 mm (1' 6")

2 m

1 m

3 m

4 m

5 m

6 m

7 m

8 m

Primary Site ID – Freestanding Pylon Scale 1:20

DESIGN OPTION 1 (PREFERRED)

Sign face = approx. 20 sq m NOTE: Variance required

Alternate colours and edge detail

111 Princes’ Boulevard

111 Princes’ Boulevard

Lighting Option 1 (Cut-out logo and lettering revealing internal

background illumination)

Signface colour to match building

Static LED image display with alpha/numeric copy only. Message must

remain static for a min. 10 sec. with 1 sec. transition (no flashing or scrolling)

Illuminated Municipal Address (push through letters)

Blue edge lighting to match PMS 8203C as closely as possible (pantone from blue version of Hotel X logo)

± 8

,300 m

m (

27' 2

")

±1,1

00 m

m

NOTE: Sign to include Electrical hook-up. Run 2 conduits: one for 20 AMP - 120 Volt, and one for Data Cat 5

Concrete base details TBD; to be coordinated with landscaping

Primary Site ID – Design Option 1 Signage and Wayfinding Program – Hotel X // Aug 18, 2014 // Page 8

Page 7: SIGNAGE & WAYFINDING PROGRAM HOTEL X

entro Entro Communications Inc. and Gottschalk+Ash 33 Harbour Square, Suite 202, Toronto, Canada M5J 2G2 T: 416-368-6988 entro.com

OPTION 1

Primary Site ID – Design Option 1 Signage and Wayfinding Program – Hotel X // Aug 18, 2014 // Page 9