KEY PLAN
BUILD
ING
1
BUILDING 2 BUILDING 3
COMMUNITY BUILDING
KINGSRIDGE RD.
OWNER: COMMUNITY HOUSING PARTNERS, CORP.448 DEPOT ST, N.E. CHRISTIANSBURG, VIRGINIA 24073(540) 382-2002(540) 381-8270 FAXWWW.COMMUNITYHOUSINGPARTNERS.ORG
ARCHITECT: CHP DESIGN STUDIO448 DEPOT ST, N.E.CHRISTIANSBURG, VIRGINIA 24073(540) 382-2002(540) 381-8270 FAXWWW.CHPDESIGNSTUDIO.ORG
CONTRACTOR: CHP CONSTRUCTION448 DEPOT ST, N.E. CHRISTIANSBURG, VIRGINIA 24073(540) 382-2002(540) 381-8270 FAXWWW.COMMUNITYHOUSINGPARTNERS.ORG
SHEET
SHEET NAME
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
STANDARD ABBREVIATIONSACP ACOUSTIC PLASTERACT ACOUSITCAL CEILING TILEALUM ALUMINUMARCH ARCHITECTURALAT ASPHALT TILEAVG AVERAGEAFF ABOVE FINISHED FLOORALT ALTERNATEAB ANCHOR BOLTABS AIR BARRIER SYSTEMAPPROX APPROXIMATE
BLK BLOCKBRG PL BEARING PLATEBDRM BEDROOMBSMT BASEMENTBRG BEARINGBM BENCHMARKBRK BRICKBW BOTH WAYSBD BOARDBLKG BLOCKINGBLDG BUILDING
CPT CARPETCEM CEMENTCFM CUBIC FEET PER MINUTECONT CONTINUOUSCI CAST IRONCTR CENTERCL CENTERLINECPL CEMENT PLASTERCLG CEILINGCT CERAMIC TILECLST CLOSETC TO C CENTER TO CENTERCONST CONSTRUCTIONCW COLD WATERCONC CONCRETECMU CONCRETE MASONRY UNITCSMT CASEMENTCJ CONTROL JOINT
DR DOORDTL DETAILDH DOUBLE HUNGDIA DIAMETERDIM DIMENSIONDN DOWNDW DISHWASHERDS DOWNSPOUTDWG DRAWINGDBL DOUBLEDF DRINKING FOUNTAIN
EQUIP EQUIPMENTEA EACHELEV ELEVATIONEST ESTIMATEDEW EACH WAYEXIST EXISTINGEXT EXTERIOREQ EQUALEWC ELECTRIC WATER COOLEREJ EXPANSION JOINTELEC ELECTRICAL
FD FLOOR DRAINFDN FOUNDATIONFFE FINISHED FLOOR ELEVATIONFIN FINISHFL FLOORFO FINISHED OPENINGFOC FACE OF CONCRETEFOF FACE OF FINISHFOS FACE OF STUDFS FULL SIZEFTG FOOTING
GA GAUGEGALV GALVANIZEDFI GALVANIZED IRONGIWT GLAZED INT WALL TILEGL GLASSGWB GYPSUM WALL BOARDGYP BL GYPSUM BLOCK
HB HOSE BIBBHC HOLLOW COREHDWE HARDWAREHORIZ HORIZONTALHGT HEIGHTHM HOLLOW METALHMF HOLLOW METAL FRAME
ID INSIDE DIMENSIONINSUL INSULATIONINT INTERIOR
JT JOINT
KIT KITCHEN
LL LIVE LOADLAV LAVATORYLINO LINOLEUMLR LIVING ROOMLT LIGHT
MFG MANUFACTURINGMECH MECHANICALMFR MANUFACTURE(ER)MAR MARBLEMATL MATERIALMAX MAXIMUMMTL METALMO MASONRY OPENINGMIN MINIMUMMLDG MOULDING
NA NOT APPLICABLENAT NATURALNIC NOT IN CONTRACTNO NUMBERNOM NOMINALNTS NOT TO SCALE
OA OVERALLOPNG OPENINGOC ON CENTEROD OUTSIDE DIAMETEROHSD OVERHEAD SECTIONAL DOOROFCI OWNER FURNIHSED CONTRACTOR INSTALLEDOSB ORIENTED STRAND BOARD
PSF POUNDS PER SQ. FOOTPSI POUNDS PER SQ. INCHPT PRESSURE TREATEDPLAS LAM PLASTIC LAMINATEPNT PAINT(ED)PL PLATEPL BD PLASTER BOARDPLYWD PLYWOODPNL PANELPROJ PROJECTPR PAIRPLAS PLASTER
QT QUARRY TILEQTY QUANTITY
REQD REQUIREDRAD (R) RADIUSRA RETURN AIRRDM RANDOMRB RUBBERREBAR REINFORCING BARREF REFRIDERATORREV REVISIONRM, RMS ROOM, ROOMSRO ROUGH OPENINGRT RUBBER TILER RISER(S)
SIM SIMILARSHTG SHEATHINGS&V STAIN & VARNISHSC SOLID CORESCFT STRUCTURAL CLAY FACING TILESCH SCHEDULESECT SECTIONSHT SHEETSPECS SPECIFICATIONSSQ FT SQUARE FEETSS STAINLESS STEELSTL STEELSTOR STORAGESTR STRUCTURALSF SQUARE FOOTSTD STANDARDSQ SQUARESYP SOUTHERN YELLOW PINESPF SPRUCE PINE FIR
TC TERRA COTTATHK THICK (NESS)T TREADTHOLD THRESHOLDTYP TYPICALT&G TONGUE & GROOVETOS TOP OF STEELTOW TOP OF WALLTOC TOP OF CONCRETE
UNFIN UNFINISHEDUR URINALUNO UNLESS NOTED OTHERWISE
VERT VERTICALVEST VESTIBULEVT VINYL TILEVB VAPOR BARRIERVCT VINYL COMPOSITE TILE
W WIDTHWC WATER CLOSETWD WOODWTRSTR WEATHER STRIPPEDWI WROUGHT IRONWP WATERPROOFINGWH WATER HEATERW/ WITHW/O WITHOUTWWM WELDED WIRE MESHWM WIRE MESHWWF WELDED WIRE FABRICWF WIDE FLANGEWRB WEATHER RESISTIVE BARRIER
DESIGNED
DRAWN
CHECKED
APPROVED
COMM#
THE STUDIO
THE STUDIO
LOCATION MAP
VICINITY MAP
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
6/13/2017 5:26:54 PM
T101
TITLE SHEET
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CLU
BH
OU
SE
BU
ILD
ING
RIC
HM
ON
D, V
IRG
INIA
KINGSRIDGE APARTMENTSCLUBHOUSE BUILDING
RICHMOND, VIRGINIA
DCC, CMA
CMA
1603
09/16/2016
INDEX OF DRAWINGS
06/13/17 T101 TITLE SHEET09/16/16 LS101 LIFE SAFETY PLAN09/16/16 HC101 ACCESSIBILITY DETAILS01/31/17 EC101 EARTHCRAFT DETAILS01/31/17 S1 FOUNDATION PLAN01/31/17 S2 FOUNDATION DETAILS01/31/17 S3 ROOF FRAMING PLAN01/31/17 S4 STRUCTURAL WALL SECTIONS01/31/17 S5 STRUCTURAL DETAILS01/31/17 S6 DETAILS09/16/16 A101 FLOOR PLAN AND WALL TYPES03/15/17 A151 REFLECTED CEILING PLAN09/16/16 A201 CLUBHOUSE EXTERIOR ELEVATIONS NORTH & EAST09/16/16 A202 CLUBHOUSE EXTERIOR ELEVATIONS SOUTH & WEST03/15/17 A301 BUILDING SECTIONS03/15/17 A302 WALL SECTIONS03/15/17 A601 FINISH SCHEDULE, DOOR SCHEDULES, AND DETAILS03/15/17 A602 INTERIOR ELEVATIONS, WINDOW SCHED. AND DETAILS09/16/16 A801 ENLARGED TOILET PLANS & INTERIOR ELEVATIONS, TOILET
ACCESSORY SCHEDULE03/15/17 P001 LEGEND, NOTES AND ABBREVIATIONS03/15/17 P002 FIXTURE PLATES03/15/17 P101 FIRST FLOOR PLAN03/15/17 P601 RISER DIAGRAM03/15/17 M001 LEGEND, NOTES AND ABBREVIATIONS03/15/17 M101 FIRST FLOOR PLAN03/15/17 M501 DETAILS03/15/17 M502 DETAILS03/15/17 E001 LEGEND, NOTES AND ABBREVIATIONS03/15/17 E101 FIRST FLOOR LIGHTING PLAN03/15/17 E201 FIRST FLOOR POWER PLAN03/15/17 E501 DETAILS AND SCHEDULES03/15/17 E601 LIGHTING DETAILS
PROPERTY LOCATION
PROPERTY LOCATION
ISSUE/REVISION SCHEDULENO. DATE DISCIPLINE DESCRIPTION1 3/15/17 BO COMMENTS2 6/13/17 VHDA COMMENTS
D D D
WWWWH
DW
A-3 ASSEMBLY885 SF
59 OCC.
45 MIN. DOOR
(30'
FIR
E SE
PAR
ATIO
N D
ISTA
NC
E)
15' -
0 1
/4" T
O IM
AGIN
ARY
LOT
LIN
E
MAINT SHOP15 LAUNDRY
13
VESTIBULE16
FITNESS14
H/C MEN'S TOILET12
H/C WOMEN'STOILET
11
MECH/JANITORCLOSET
10
CORRIDOR9
RECEPTION3
CONF ROOM5
FILES6
MECH/ELC7
STORAGE8
COMMUNITYROOM
1
KITCHENETTE2
WORK ROOM4
MAX TRAVEL DIST - 66'
PROVIDE 18"X24" OCCUPANT LOAD SIGN. 'MAXIMUM 59 OCCUPANTS'
173 SF4 OCC.
LIFE SAFTEY PLAN
OCCUPANT LOAD
REQUIRED EXIT CAPACITY
MAJOR EGRESS PATH
XX
90
1-HOUR RATED FIRE SEPARATION (TABLE 509)
XX EXIT CAPACITY PROVIDED
PROJECT: 1603 Kingsridge Community CenterCODE REVIEW COMPLETED BY: Doug CovingtonCODE REVIEW CHECKED BY: Colin ArnoldDATE: 10-12-16LOCAL JURISDICTION HAVING AUTHORITY
City: County: Henrico CountyState Fire Marshal:
APPLICABLE CODES:Building Code: Virginia Construction Code 2012Mechanical Code: 2012 Virginia Mechanical CodePlumbing Code: 2012 Virginia Plumbing CodeElectrical Code: 2012 Virginia Construction CodeFire Code: 2009 2012 Virginia Fire Prevention Code
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION:Section 302.
Assembly, A3 and Business, BCHAPTER 4 SPECIAL DETAILED REQUIREMENTS:
Section 420.5Automatic sprinkler system - Not required.
Section 420.6 Fire alarm systems and smoke alarms. Fire alarm not required.
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS:Section 503.
Group: B-Business; A-3, Assembly (non-separated, mixed use)Construction Type: VBAllowable Stories: 1 (40 feet) (most restrictive) Actual: 1 (21’-2”)Allowable Area: 6,000sf (most restrictive) Actual: 2,726 S.F.
CHAPTER 6 TYPES OF CONSTRUCTION:Section 602.
Construction Classification: Type VBTable 601 Fire Resistance Rating Requirements for Building Elements:
Building Elements Fire Resistance Rating (HRS) Fire Resistance Rating (HRS)Required VB Provided VB
Structural Frame 0 0Exterior Bearing Walls 0 0Interior Bearing Walls 0 0Exterior Nonbearing Walls 0 0Interior Nonbearing WallsExcept @ Incidental Use Areas 0 0Floor Construction 0 0Roof Construction 0 0
Table 602 Fire Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance
Fire Separation Distance Fire Resistance Rating (HRS)
Greater than 30 feet 0
CHAPTER 8 INTERIOR FINISHES:Table 803.9 Interior Wall and Ceiling Finish Requirements by Occupancy
Group Exit enclousure and exit passagways Corridors Rooms and Enclosed Spaces
A-3, Assembly Class B Class B Class CB-, Business Class B Class C Class C
CHAPTER 9 FIRE PROTECTION SYSTEMS:Section 906.1.
Portable Fire ExtinguishersPortable fire extinguishers shall be installed in the following locations:1. In new and existing Group A, B, E, F, H, I , M, R-1, R-2, R-4 and S occupancies.
Section 907 Fire Alarm and Detection SystemsSmoke Alarms.Single- and multiple-stations smoke alarms shall be installed in accordance with Section 907.2.11.
907.2.1 Group A. (not required)A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group A occupancies where the occupant load due to the assembly occupancy is 300 or more. Group A occupancies not separated from one another in accordance with Section 707.3.10 shall be considered as a single occupancy for the purposes of applying this section.
907.2.2 Group B. (not required)A manual fire alarm system shall be installed in Group B occupancies where one of the following conditions exists: 1. The combined Group B occupant load of all floors is 500 or more. 2. The Group B occupant load is more than 100 persons above or below the lowest level of exit discharge. 3. The fire area contains an ambulatory care facility.
907.2.11 Single- and multiple-station smoke alarms. Listed single- and multiple-station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.4 and NFPA 72.
Section 907.5.2.3Visible Alarms.Visible alarm notification appliances shall be provided in accordance with Sections 907.5.2.3.1 through 907.5.2.3.4.
CHAPTER 10 MEANS OF EGRESS:Section 1003.3.3.
Horizontal ProjectionsStructural elements, fixtures or furnishings shall not project horizontally from either side more than 4 inches over any walking surface between the heights of 27 inches and 80 inches above the walking surface.
Section 1003.6.Means of Egress ContinuityThe path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be places in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel.
Section 1004.Design Occupant LoadTable 1004.1.2 Maximum Floor Area Allowances per Occupant
Function of Space Floor Area in SQ. FT. Per Occupation Actual
Assembly without fixed seatsUnconcentrated (tables and chairs) 15 net 885/59 occ.Accessory storage areas, mechanicalequipement room 300 gross 208/1 occ.Business area 100 gross 1,460/15 occ.Exercise rooms 50 gross 176/4 occ.
Total: 2,726 S.F. /79 Occupants
Section 1005.1. Minimum Required Egress WidthThe means of egress width shall not be less than required by this section. The total width of means of egress in inches shall not be less than the total occupant load served by the means of egress multiplied by 0.3 inches per occupant for stairways and by 0.2 inches per occupant for other egress components. The width shall not be less than specified elsewhere in this code. Multiple means of egress shall be sized such that the loss of any one means of egress shall not reduce the available capacity to less than 50 percent of the required capacity. The maximum capacity required from any story of a building shall be maintained to the termination of the means of egress.Without sprinkler system:
Other egress components 0.2 inches per occupant = 0.2 * 59 = 11.8 inchesSection 1005.2.
Door EncroachmentDoors, when fully opened, and handrails shall not reduce the required means of egress width by more than 7 inches. Doors in any position shall not reduce the required width by more than one-half. Other nonstructural projections such as trim and similar decorative features shall be permitted to project into the required width a maximum of 1 ½ inches on each side.
Section 1007.1Accessible means of egress required.Accessible means of egress shall comply with this section. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress are required by Section 1015.1 or 1021.1 from any accessible space, each accessible portion of the space shall be served by not less than two accessible means of egress.
Section 1008.1Doors.Means of egress doors shall meet the requirements of this section. Doors serving a means of egress system shall meet the requirements of this section and Section 1020.2. Doors provided for egress purposes in numbers greater than required by this code shall meet the requirements of this section.Means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors. Mirrors or similar reflecting materials shall not be used on means of egress doors. Means of egress doors shall not be concealed by curtains, drapes, decorations or similar materials.
Section 1016.1 Travel Distance Limitations.Exits shall be so located on each story such that the maximum length of exit access travel, measured from the most remote point within a story to the entrance to an exit along the natural and unobstructed path of egress travel, shall not exceed the distances given in Table 1016.1.
TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCE
Occupancy Without Sprinkler System(feet)
A, E, F-1, I-1, M, R, S-1 200B 200
TABLE 1018.1 Corridor Fire-Resistance Rating (Not required) Occupant Load not greater than 30.
TABLE 1021.1 MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
Occupant Load (persons per story) Minimum Number of Exits
1-500 2
Section 1027.1.Exit DischargeExits shall discharge directly to the exterior of the building. The exit discharge shall be at grade or shall provide direct access to grade. The exit discharge shall not reenter a building.
CHAPTER 12 INTERIOR ENVIRONMENT:Section 1205.1.LightingEvery space intended for human occupancy shall be provided with natural light by means of exterior glazed openings in accordance with Section 1205.2 or shall be provided with artificial light in accordance with Section 1205.3. Exterior glazed openings shall open directly onto a public way or onto a yard or court in accordance with Section 1206. Section 1205.2.Natural LightThe minimum net glazed area shall not be less than 8 percent of the floor area of the room served.Section 1205.3.
Artificial LightArtificial light shall be provided that is adequate to provide an average illumination of 10 foot-candles over the area of the room at a height of 30 inches above the floor level.
Section 1208.2.Minimum Ceiling HeightsOccupiable spaces, habitable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches. Bathrooms, toilet rooms, kitchens, storage rooms and laundry rooms shall be permitted to have a ceiling height of not less than 7 feet.
CHAPTER 14 EXTERIOR WALLS:Section 1404.4.
MasonryExterior walls of masonry construction shall be designed and constructed in accordance with this section and Chapter 21. Masonry units, mortar and metal accessories used in anchored and adhered veneer shall meet the physical requirements of Chapter 21. The backing of anchored and adhered veneer shall be of concrete, masonry, steel framing or wood framing.
Section 1404.10.Fiber-Cement SidingFiber-cement siding shall conform to the requirements of ASTM C 1186, Type A, and shall be so identified on labeling listing an approved quality control agency.
Section 1405.3.3.Minimum Clear Airspaces and Vented Openings for Vented CladdingFor the purposes of this section, vented cladding shall include the following minimum clear airspaces.
1. Vinyl lap or horizontal aluminum siding applied over a weather-resistive barrier as specified in this chapter.2. Brick veneer with a clear airspace as specified in this code.
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
LS101
LIFE SAFETYPLAN
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/8" = 1'-0"LS1011 COMMUNITY BUILDING LIFE SAFETY PLAN
APPLICABLE CODES
BUILDING CODE:
MECANICAL CODE:
PLUMBING CODE:
ELECTRICAL CODE:
FIRE CODE:
ENERGY CODE:
ACCESSIBILITY CODE:
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
PERMITTED PROVIDEDBUILDING HEIGHTNO. OF STORIESAREA (PER-STORY)
FIRE - RESISTANT RATING REQUIREMENTS FOR BUILDING ELEMENTS AS PER TABLE 601
REQUIRED (HR) PROVIDED (HR)BUILDING ELEMENTSSTRUCTURAL FRAMEEXTERIOR BEARING WALLSINTERIOR BEARING WALLSEXTERIOR NONBEARING WALLSINTERIOR NONBEARING WALLSEXCEPT @ INCIDENTAL USE AREASFLOOR CONSTRUCTIONROOF CONSTRUCTION
FIRE - RESISTANT RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPERATION DISTANCE AS PER TABLE 602
TYPE OF CONSTRUCTION
OCCUPANCY (HOURS)
FIRE SEPARATION DISTANCE
TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
CORRIDORSROOMS AND ENCLOSED SPACESGROUP
EXIT ENCLOSURES AND EXIT PASSAGEWAYS
SF OCC.
VCC 2012
2012 VMC
2012 VPC
2012 NEC
2012 VFPC
2012 VECC
2010 ADA, 2009 ANSI A117.1, UFAS
A-3, ASSEMBLYB, BUSINESS
VB
40 21' - 2"1 16,000 2,726
0 00 000 00 0
0 00 0
0
X ≥ 30 VB 0
A-3, ASSEMBLY B B C
B, BUSINESS B C C
2,7261668
5917
FITNESS 173 480 OCCUPANTS
48" min
15" min
6" max8" min
9" min 27
" min
36" m
ax to
17"-19"
8" min 6" max
9"34
" max
60" min
32" m
in
60" m
in
36" m
in
36" min
30" m
in
59"min w/floor mounted WC
56"min w/wall hung WC
54" min
6" m
ax
16"-
18"
12"max
33"-
36"56
" min
32" min
4" m
ax
30" m
in
4" max
44" m
ax
17"m
ax
30" m
in
48" min16"-18"
48" m
ax*
48" m
ax *
40" m
ax
39" m
ax
36" m
ax
27" c
lear
12"min
12"min 4"
max
cle
ar
48" m
in
36" min
48" min
48" m
in
48"
36"
32"-36" min(section 403.5)
34"
12"12"
12" min
12" min
X
X
48" m
ax*
15" m
in
48" m
ax*
48" m
ax*
48" m
ax*
48" m
ax *
Any Width
15" m
in
48" m
ax
30" m
in
60" min (length of tub)
30" m
in
75" min (length of tub)
12" min
24" m
in
12" max 15" max
24" m
in
12" max24" max
12" m
in
8"-1
0"
48" m
ax
33"-
36" 3"
-6"
33"-
36" 3"
-6"
18" m
in
4" max
48" min5" max
17"-
19"
42" min
33"-
36"
12"max
39" -
41"
18" m
in
39" - 41" 12" min24" min
18" m
in
36" m
ax
15"-
36"
54" min
44" m
ax*
60" min60" min
60" m
in
60" min
96" min 96" min 60" min 96" min96" min 132" min 60" min
full
leng
th o
f par
king
spa
ce
20' min
60" m
in
1 1/4" - 1 1/2" 1 1/2" min clear
34"
34"
4"-7
"
1 1/2" max
11" min
18" m
in1
1/2"
min12" m
in
24" min
42" max36" max24" min
48" m
ax
24" min
36" max
48" m
ax
42" max
66" m
in
60" min
18" min
8"-1
0"18" m
in
4" max
48" min
36" m
in36
"
36"
18"
4" max
36" m
in30
" min
3" m
ax1
1/2"
max
15"-16"
2 1/2" max
3" m
ax1
1/2"
max
2 1/2" max
22"-23"
15"-16"
14"-
15"
16" min
27" max
abov
e gr
ab b
ar
48" m
ax
27" max
48" m
ax
38" m
in
60" min
6" max
6" m
ax
60" min
36"
24"-36" 36" min
6" m
ax 6" max 6" max
48" m
ax
38" m
in
15" max
15" max
40" min 40" min
60" min 60" min
34" m
ax34
" max
30" min clear*
30" min clear*
15" max
48" m
ax
38" m
in
5/8"
min
- 2"
max
24" max
X > 15"
60" m
in
60" min
60" m
in 48" m
in
30" min
48" m
in
30" min
24" m
ax
X >
24"
36" min
15" m
in
48" m
ax
48" m
ax
44" m
ax
20" max 20"-25" max
10" - 24" max
34" m
ax
46" m
ax
10" max
15" m
in
48" m
ax
10" max
48" m
ax
34" m
ax
25" max
30" m
in
17" min - 25" max
30" m
in
11" min
27" m
in
8" min
9" m
in
6" max
9" m
in
36" min 12" min12" min60" min
36" m
in24
" min
60" m
in
30" min
48" m
in
30" min
48" m
in
30" min
48" m
in
15" max
29"
15"-
48" 48
" max 72
" min
5"
68" min
54" m
in
51" m
in
36" min
9" clr min
48" m
in to
60" m
ax to
top
of te
xt
60" min
60" m
in
60" m
in
Door Width 48" min
60" m
in
Door Width 48" min Door Width
60" m
in
48" m
in*
12" min*
48" m
in
12" min*
18" min
42" m
in**
42" m
in*
24" min
22" min
36" min
48" m
in
24" min42" m
in42
" min
32" min 32" min
24" m
ax
22" min
24" min
42" m
ax*
17" min
48" min
24" min
15" min
24" min
24" m
in
17"-
19"
90°
24" m
ax
18"
36" min
80" min
42" min
51" m
in
54" m
in
68" min
54" m
in
51" m
in
36" min
54" min
60" m
in
36" min 36" min
60" min
60" m
in
36" min
54" m
in
1/2" max loop
1/4" max
1/4" max 1/2" max
1/4"-1/2"
24"
36" min
60" m
in
42" min
54" m
in
Unobstructed Forward Reach Obstructed High Forward Reach Obstructed High Forward Reach
Unobstructed Side Reach Obstructed High Side ReachObstructed High Side Reach
6HC101
DRINKING FOUNTAIN
11HC101
LAVATORIES AND BATHTUBS
17HC101
SIGNS AND SYMBOLS
10HC101
WATER CLOSETS
12HC101 SCALE: NOT TO SCALE
URINALS
15HC101
LAVATORY ACCESSORIES
14HC101
OPERABLE PARTS
13HC101
LAUNDRY EQUIPMENT
5HC101
RAMPS
8HC101
PARKING SPACES
4HC101
STAIRS AND HANDRAILS
16HC101
ROLL-IN SHOWERS
3HC101
KITCHENS
2HC101
BUILDING BLOCKS
7HC101
ELEVATORS
9HC101
DOORS AND DOORWAYS
1HC101 SCALE: NOT TO SCALE
CHANGES IN LEVEL
Clear Floor Areaat Lavatory
Drinking Fountain Spout
Location (Plan)
Spout Height & KneeClearance for Wheelchair
Accessible Fountain
Note:Equipment ispermitted inthe shadedarea.
Sink Height & Knee Clearance
Note:Equipment ispermitted inthe shadedarea.
Water Closet Back WallGrab Bars
Accessible Water Closet Compartment
Clear Floor Areas at Water Closets
MountingHeight & Flush
Controls
Clear Floor Area
Symbol Display
Conditions
International Symbol ofAccessibility
Clear Floor Area
For Public Toilet
SoapDish
Towel Dispenser& Waste
MirrorsTypical & Tilt
SoapDispense
r
AccessibleDrinking Fountain
Extended Surface Ramp Edge Protection
flaredsides1:10maxslope
Sides of Curb Ramps
PlantingBeds
PlantingBeds
Diagonal Curb Ramps
Cut Through at Island
Handrail Height and Top &Bottom Extensions at
Ramps
Handrail Top & Bottom Extensions
at Stairs and Ramps
Thermostat ElectricalReceptacle
SwitchControls
BreakerPanel
International TTY
Symbol
Volume-ControlledTelephone
International Symbolof Access forHearing Loss
Mailboxes (Side Reach)
* Height tohighest
operableparts which
areessential to
basicoperation
Closet Shelf and Rod
back wall
head
end
wal
l
cont
rol e
nd w
all
Clearance without Permanent Seat
back wall
head
end
wal
l
cont
rol e
nd w
all
Clearance With Permanent Seat
Grab Bars for Bathtubswithout Permanent Seat
Grab Bars for Bathtubswith Permanent Seat
Grab Bars for Bathtubs withPermanent Seat
Grab Bars for Bathtubs withoutPermanent Seat
TowelBar
1:12 m
ax1:10 m
ax
1:10 m
ax
1:12 max
1:12
max 1:
10 m
ax
1:10
max
Water Closet Height andSide Wall Grab Bars
Recessed Dispensers LocationTop Loading Front Loading
* Height tohighest
operableparts which
areessential to
basicoperation
MedicineCabinet
landingramp runlanding
landing width equal or greater than ramp width
Ramp Landings
landingramp run
ram
p ru
n
Ramp Landings
Car Parking Space and Access Aisle Van Parking Space and Access Aisle Passenger Loading Zone Access Aisle
parking block (optional) accessible aisle area to be marked
accessible aisle area to be marked
Handrail Cross Section
and Clearance
Handrail Height
at Ramps
Handrail Height
at Stairs
Curb Ramp at Island
radius 1/2" max
Treads and Risers for Accessible
Stairways
Protruding DispenserBelow Grab Bar Location
Protruding DispenserAbove Grab Bar Location
Clear Floor AreaFor Residential Toilet
Type A(Exception 1003.11.2.4.4)
Lavatoryoverlappermitte
dother fixturesnot allowed inthis area back wall
head
end
wal
l
cont
rol e
nd w
all
back wall
head
end
wal
l
cont
rol e
nd w
all ℄
offsetcontrolslocation
Location ofBathtub Controls
endwall
seat
wal
l
back wall
cont
rol w
all
seat
wal
l
back wall
cont
rol w
all
seat
*Transfer-Type ShowerCompartment Size and
Clearance
Grab Bars inTransfer-Type Showers
end
wal
l
back wall
seat
Rectangular ShowerCompartment Seat
seat
L-Shaped ShowerCompartment Seat
back wall
seat
Standard Roll-in-Type ShowerControl and Handshower
Location
end wall
seat
End Wall (Elevation)
seat
Grab Bars in StandardRoll-in-Type Showers
side
wal
l
back wall
seat
℄℄ ℄
*Standard Roll-in-Type ShowerCompartment Size and
Clearance
side
wal
l
end
wal
l
side
wal
l
back wall
seat
℄℄ ℄
*Alternate Roll-in-Type ShowerCompartment Size and Clearance
seat wall
end
wal
l
side
wal
l
back wall
seat
Grab Bars in AlternateRoll-in-Type Showers
seatwall
end
wal
l end
wal
l
side
wal
l
back wall
seat
Shower (Plan)
seatwall
back wall
Back Wall (Elevation)
seat
Alternate Roll-in-Type ShowerControl and Handshower
Location
d/w
worksurface
ref
d/w
ref
worksurface
worksurface
worksurface
d/w
ref ref
U-Shaped Kitchen Clearance Pass-Through Kitchen Clearance
open
open
Work Surface in Kitchens Clearance (Elevation)
Kitchen Sink Clearance (Elevation)
Transfer-Type ShowerControls
and Handshower Location
controlwall
℄
Character Height
℄
℄
℄
Top Loading (Plan) Front Loading (Plan)
Maneuvering Clearancein an Alcove Parallel
Approach
Circular Turning Space Forward Approachto an Element
Maneuvering Clearance in an AlcoveForward Approach
Maneuvering Clearance in an
AlcoveForward Approach
clear floor areaprotruding element
Knee Clearance Plan
clear floor areaprotruding element
Toe Clearance Plan
protruding element
Knee Clearance Elevation
protruding element
Toe Clearance ElevationT-Shaped Turning Space Rectangular Clear
Floor Space
Parallel Approach
to an Element
Maneuvering Clearancein an Alcove
Parallel Approach
Hoistway and Elevator Entrances
NOTE: The automatic door reopening device isactivated if an object passes through either line A orline B. Lines A and B represent the vertical locationsof the door reopening device not requiring contact.Minimum Inside Dimensions of Elevator Cars
botto
m o
f tex
t℄
Location of Sign at Doors
doorlatch
*If door has both a closer and latch
Latch ApproachPush Side
*48" if closer is provided
Note: 54" min if closer is provided
Latch ApproachPull Side
**48" min if door has both latch and closer provided
Front Approach Push Side
Hinge ApproachPush Side
Front ApproachPull Side
Slide ApproachSliding Doors
Doorway Depth
Sliding Door
Front ApproachSliding Doors
Hinged Door Latch ApproachSliding Doors
Peep Hole
48" max heightto highest operableparts essential tooperation
clear area centeredon appliance
offset from centerof door opening
curb
curb
curb of ramp flares paintedif adjacent curb is painted
*Note: Inside finished dimensions measured at the center points of opposing sides
seat
℄
℄
℄
top
of s
pout
Two Doors in a Series
Two Doors in a Series Two Doors in a Series
*If both closer and latch are provided
Note: Operable parts foressential operation of
systems shall be placedwithin reach ranges noted in
2/HC101. Rectangular clear
floor space shall be provided
on the centerline of eachoperable component.
Operable parts shall beoperable with one hand and
shall not require tightgrasping, pinching, ortwisting of the wrist.
alt door location
*36" min if included in part of t-shaped turning space
*fornon-circularhandrail shapes,refer to codesection 505.7
16 feet² min
Centered Door Location Side (Off-Centered Door) Location Any Door Location Any Door Location Existing Car Configurations
Carpet on Floor Surfaces
Carpet on Floor Surfaces
Beveled Changes in Level
21
21
carpet pad
Lavatory Clearance inAccessible Type 'B'
Dwelling Units
parallel approachclear floor spacecentered onlavatory
min
Hinge ApproachPull Side
Hinge ApproachPull Side
AREA OF
REFUGE
American National Standard InstituteAccessible and Usable Buildings and Facilities
ICC/ANSI A117.1-Published by the International Code Council
FF
FF
shelf
rod
to b
otto
m o
fre
flect
ing
surfa
ce
to b
otto
m e
dge
to c
ente
rline
SCALE: NOT TO SCALE
SCALE: NOT TO SCALE SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
SCALE: NOT TO SCALESCALE: NOT TO SCALE
SCALE: NOT TO SCALE SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
SCALE: NOT TO SCALESCALE: NOT TO SCALE
SCALE: NOT TO SCALESCALE: NOT TO SCALE
SCALE: NOT TO SCALE
℄
to a
t lea
st (1
) she
lf
NOTE: FLUSH VALVES ON ACCESSIBLE TOILETS SHALL BE LOCATED ON THE OPEN SIDE OF THE FIXTURE.
2009
Disclaimer: This set of ICC/ANSI A117.1-2003 Standards have been indicated here for reference purposes only. In no way does this sheet represent all applicaple components of the "Accessible and Usable Buildings and Facilities" national standard. For clarifications, accompanying texts, descriptions, or interpretations refer to the National Standard code. The excerpts from the National Standard indicated here have been included for their relevance to this particular project.
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
HC101
ACCESSIBILITYDETAILS
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1 1/2" 1/2" 1 1/2"
FLASH WINDOWSAND OTHEROPENINGS
MIN 6 MILPOLY
SEAMS SEALED
FOAM INSULATION PROVIDES THERMALBREAK FOR SLAB AND FUNCTIONSAS AN EXPANSION JOINT
SEAL
INSULATE AND AIRSEAL BEHIND TUBWITH SEALED SHEET MATERIAL
GASKET
SEALWITH FOAM
SEAL
SEAL
AIR SEAL GASKET
SEAL
2EC101 NOT TO SCALE
DETAIL 3EC101 NOT TO SCALE
DETAIL 4EC101 NOT TO SCALE
DETAIL 5EC101 NOT TO SCALE
DETAIL 6EC101 NOT TO SCALE
DETAIL 7EC101 NOT TO SCALE
DETAIL 8EC101 NOT TO SCALE
DETAIL 9EC101 NOT TO SCALE
DETAIL
10EC101 NOT TO SCALE
DETAIL 11EC101 NOT TO SCALE
DETAIL 12EC101 NOT TO SCALE
DETAIL 13EC101 NOT TO SCALE
DETAIL 14EC101 NOT TO SCALE
DETAIL
15EC101 NOT TO SCALE
DETAIL 16EC101 NOT TO SCALE
DETAIL 17EC101 NOT TO SCALE
DETAIL 18EC101 NOT TO SCALE
DETAIL 19EC101 NOT TO SCALE
DETAIL
20EC101 NOT TO SCALE
DETAIL 21EC101 NOT TO SCALE
DETAIL 22EC101 NOT TO SCALE
DETAIL 23EC101 NOT TO SCALE
DETAIL 24EC101 NOT TO SCALE
DETAIL 25EC101 NOT TO SCALE
DETAIL
27EC101 NOT TO SCALE
DETAIL 28EC101 NOT TO SCALE
DETAIL 29EC101 NOT TO SCALE
DETAIL 30EC101 NOT TO SCALE
DETAIL26EC101 NOT TO SCALE
DETAIL
MONOLITHIC SLAB
CAULK
RIGID BOARD
CONDITIONED SPACE
USE BACKER ROD TOFILL GAPS BETWEEN WINDOW AND ROUGH OPENINGS
STUD CAVITIESSHALL BE BLOCKEDAT LOCATIONS OFVARYING CEILINGHEIGHT, SUCH ASIN COMMON WALLSBETWEEN ADJACENTHOMES, TO RETARDAIRFLOWTHROUGH THE WALLCAVITIES.
THE SPACE BETWEENTHE FRAMING FORWINDOW OR DOOR(INCLUDING ATTICACCESS) ROUGHOPENINGS AND THEINSTALLED UNITS SHALLBE SEALED WITHNON-EXPANDING SPRAYFOAM SEALANT, CLOSEDFOAM BACKER ROD,SPRAY APPLIEDINSULATION, OR OTHERSUITABLE SEALANT.CELLULOSE, FIBERGLASSOR ROCK WOOL BATTINSULATION IS NOTACCEPTABLE AS ASEALANT BUT CAN BEUSED AS A BACKINGFOR A SEALANT (SUCHAS CAULK).THRESHOLDS FOREXTERIOR DOORS SHALLBE SEALEDTO THE SUBFLOOR.
SEAL
ALL PENETRATIONS THROUGHTHE BAND AREA SHALL BESEALED WITH SHEETING ANDPROPER SEALANT SUCH ASHOLES DRILLED FOR HVAC,PLUMBING AND ELECTRIC LINES.
VENT FAN
SEAL
SEAL
ALL PENETRATIONS THROUGHINSULATED FLOOR SYSTEMSOVER UNCONDITIONED AREAS(SUCH AS BASEMENTS,CRAWLSPACES, AND GARAGES) MUST BE SEALED INCLUDING DUCT, ELECTRICAL AND PLUMBING PENETRATIONS.
ALL PENETRATIONS THROUGH INSULATED CEILINGS SHALL BE SEALED WITH A PROPER SEALANT INCLUDING HVAC BOOTS, BATHROOM FANS, LIGHT FIXTURES, SECURITY AND AUDIO SPEAKERS.
RECESSED LIGHTS IN CEILINGS WITH AN UNCONDITIONED AREA ABOVE MUST MEET THE ENERGY CODE SPECIFICATION (2009 IECC SECTION 502.1.3 SECTION 1 OR 3) FOR AIR TIGHTNESS AND MUST BE INSULATION CONTACT (IC) RATED.
INSULATION DAMS PREVENT LOOSE-FILL INSULATION FROM FALLING THROUGH ACCESS
GWB HATCH LIDPUSHES UP ANDOUT OF THE WAYFOR ACCESS
ATTIC SCUTTLE HOLES THAT ARE LOCATED IN CONDITIONED SPACE SHALL BE WEATHER STRIPPED TO PROVIDE AN AIRTIGHT SEAL AGAINST THE CEILING TRIM AND DRYWALL.
ALL SEAMS SHALL BE SEALED IN BANDJOISTS BETWEEN CONDITIONED FLOORS, SINCE THE BAND IS PART OF THE BUILDING ENVELOPE.
UNCONDITIONEDSPACE
CONDITIONEDSPACE
SEAL WIRINGAND PLUMBINGPENETRATIONS
SEAL PLUMBINGPENETRATIONS
ALL HOLES IN THEFLOOR ASSEMBLYFOR PLUMBING,WIRING,DUCTWORK, ANDOTHER PURPOSESCONNECTINGCONDITIONED ANDUNCONDITIONED(AND EXTERIOR)AREAS SHALL BESEALED.PENETRATIONSFOR FLUES ANDOTHERHEAT-PRODUCINGITEMS SHALLBE SEALED WITHNONCOMBUSTIBLESHEET MATERIALSAND HIGHTEMPERATURESEALANT.
TAPE JOINTSIN FOAMSHEATHING
TAPE JOINT
EXTEND SHEATHING BELOWBOTTOM PLATE AND SEAL
ALL GAPS IN EXTERIOR SHEATHING, SUCH AS SEAMS BETWEEN ADJACENT SHEETS, SHALL BE SEALED WITH A PROPER SEALANT. ALL PENETRATIONS, SUCH AS HOLES DRILLED FOR CONDENSATION LINES AND UTILITY BOXES, SHALL BE SEALED WITH AN EXPANDING SPRAY FOAM OR EQUIVALANT. A MINIMUM OF 80% OF EXTERIOR WALL AREA SHALL HAVE BUILDING PAPER, HOUSEWRAP OR SIMILAR MATERIAL DESIGNED TO PROTECT THE WALL FROM WATER MOVING PAST THE EXTERIOR CLADDING, AND HAVE AN AIR SPACE BETWEEN THE EXTERIOR CLADDING AND WALL SHEATHING. THE SYSTEM SHALL BE INTEGRATED WITH FLASHING AND BE DESIGNED AND INSTALLED TO MINIMIZE MOISTURE MIGRATION BETWEEN THE EXTERIOR CLADDING AND THE WALL SHEATHING.
SEAL
SEAL
INSULATE (R30)
FOR FLOORS WITHCONDITIONED AREAOVER UNCONDITIONEDOPEN AREAS, THEFLOOR JOIST CAVITYSHALL BE SEALED WITHSHEET MATERIAL ORBLOCKING ANDSEALANT ABOVE THETOP PLATE OF THESUPPORTING WALL ANDINSULATED TO MINIMUMR19, EITHER WITH BATTINSULATION BETWEENFLOOR JOISTS OR WITHA COMBINATION OFJOIST INSULATION ANDINSULATED SHEATHINGON THE UNDERSIDE OFTHE FLOOR JOIST.
A SECONDARYBARRIER SHALLBE INSTALLEDBEHIND TUBSAND SHOWERSBEFOREINSTALLING BATH AND SHOWERASSEMBLIES.THE SHEETINGMATERIAL MUST BE SEALED WITHA PROPERSEALANT ANDTHE EXTERIORWALL MUST BEINSULATED TOTHE REQUIREMENTSOF THE ENERGYCODE.
SEAL TUBPENETRATION
WINDOWROUGHOPENING
ALL PENETRATIONS INDRYWALL IN INSULATEDWALLS SHALL BE SEALED WITHA PROPER SEALANT INCLUDINGWALL SWITCHES, ELECTRICALOUTLETS AND KNEEWALL DOORROUGH OPENINGS.
DRYWALL SHALL BE SEALED TO TOP PLATE ON CEILINGS SEPARATING ATTIC FROM CONDITIONED SPACE.
GASKETS, CAULK OR FOAM CAN BE USED TO AIR SEAL DRYWALL AT ANY STAGE OF THE INSTALLATION.
ATTIC ACCESS
AN INSULATED ATTICHATCH SHALL BEBUILT TO OPEN TO THE ATTIC AND FORM AN AIRTIGHT SEAL WHEN CLOSED.THE ATTIC HATCH MUST ACCOMMODATE THE "HIDEAWAY STAIRS" AND BE INSULATED TO AT LEAST R-5. ADDITIONAL POINTSMAY BE EARNED IFTHE ATTIC HATCH ISINSULATED TO R-19.
INSULATED WALL
CAULK UNDERSIS AND SEAL GAPBETWEENELECTRICAL BOXAND SHEATHINGSEAL SIS
BELOWBOTTOM PLATE
SEAL SEAMWITH TAPE
SHEATHINGPANEL
SEALFLOODLIGHTAT OPENING
SEAL AT TOP PLATE
SEAL HOSEBIB AT OPENING
SEAL TO FRAMING
WINDOWSIS
SIS
STRUCTURALLYINSULATED SHEATHING(SIS) SHALL BEINSTALLED ACCORDINGTO THE MANUFACTURER'SSPECIFICATIONS. ALLSEAMS MUST BE CUTPROPERLY AND ALLEDGES TAPED TOENSURE A CONTINUOUSAIR BARRIER.
RIGID BOARDINSULATION
SILL GASKET MEMBRANE(ALSO SERVES ASCAPILLARY BREAK)
DRYWALL AND BASEBOARD
GRAVEL BASE
MIN 6 MIL POLYUNDER SLAB
CARPET TACKATTACHED TO SLAB
GRAVELFOR DRAINAGE
R4 OR GREATER EXTERIOR SLAB INSULATION, SUCH AS FOR MONOLITHIC SLABS, MAY BE INSTALLED WITH APPROVED MEMBRANES (SUCH ASEPDM-TYPE MEMBRANES) TO PROTECT AGAINST TERMITES. ALTERNATIVELY, NON-MONOLITHIC SLABS MAY USE RIGID INSULATION BETWEEN THESTEM WALL AND THE POURED (FLOATING) SLAB, USING THE PROTECTIVE MEMBRANE AS A TERMITE FLASHING AND AS A CAPILLARY BREAK.
GRAVELBASE
GRAVEL ORDRAINAGEPLANE MATERIAL
RIGID BOARDINSULATION
SILL GASKETMEMBRANE (ALSOSERVES ASCAPILLARY BREAK)
1/2" FOAMSHEATHING CUTTO FILL VOID
DOUBLETOP PLATE
2" OF FOAMSHEATHING ORFIBERGLASS BATT
EXTERIOR WALLS FEATURING HEADERS (OVER WINDOWS AND DOOR OPENINGS) SHALL BE FRAMED WITH AT LEAST 1/2 INCH OF RIGID FOAM INSULATION BETWEEN THE 2X MEMBERS. OTHER METHODS OF ACHIEVING INSULATED HEADERS, SUCH AS BOXED HEADERS WITH INSULATION BATTS, ARE ALSO ACCEPTABLE.
1 1/2"+1/2+1 1/2"=3 1/2"
INSULATIONFILLS CORNER
DRYWALL CLIP TOHOLD DRYWALLIN PLACE
THE INTERSECTING CORNER OF TWO INSULATED WALLS SHALL BE FRAMED SUCH THAT INSULATION IS CONTINUOUS IN THE EXTERNAL WALL (CORNERS WITH UNNECESSARY 2X4'S ARE NOT PERMITTED). A "CALIFORNIA CORNER" OR TWO-STUD CORNER WITH DRYWALL CLIPS ARE METHODS OF ACHIEVING THIS.
ADVANCED CORNERCAULK BOTTOM PLATETO SUBFLOOR
CAULK BAND JOISTTO SUBFLOOR ANDPLATES AND INSULATE
CAULK BOTTOMPLATE TO SUBFLOOR
SILL GASKET OR DOUBLE-BEAD OF CAULK
THE BAND JOIST CONNECTING TWO CONDITIONED FLOORS SHALL BE INSULATED TO R19 OR GREATER.
DRYWALL AND INTERIOR WALLS ARE ATTACHED TO "LADDER," WHICHSPANS BETWEEN STUDS
THE INTERSECTION OF AN INTERIOR WALL AND AN INSULATED WALL SHALL BE FRAMED SUCH THAT INSULATION IS CONTINUOUS IN THE EXTERNAL WALL. A "LADDER" TYPE INTERSECTION IS ONE METHOD OF ACHIEVING THIS.
BLOWN INSULATION
SOFFITVENT
RAFTERBAFFLE
"SOFFIT DAM" USE BATT OR RIGID FOAM INSULATION
TO ENSURE FULLDEPTH OF ATTICINSULATION ABOVE EXTERIOR WALL TOP PLATES, ENERGY TRUSSES WITH RAISED TOP CHORD FOR JOIST/RAFTERASSEMBLIES SHALL BE USED.
ENERGY TRUSSSUPPLY LEAKAGE
SUPPLY AIR
MASTIC ATSWIVEL JOINTS
MESH TAPEAND MASTIC
MASTICCEILINGREGISTER
CAULK BETWEEN DRYWALL AND BOOT
SUPPLYLEAKAGE
ATTICINSULATION
ALL TRANSVERSESEAMS IN SUPPLYAND RETURN DUCTS,INCLUDING SUPPLYAND RETURNPLENUMS ANDLEAKAGE SITES INTHE AIR HANDLER,SHALL BE SEALEDWITH DUCT MASTICAND FIBEROUSREINFORCING MESHACCORDING TOSMACNASPECIFICATIONS.DUCT TAPE IS NOT ASUITABLE SEALANTFOR DUCTS BUT MAYBE USED FORSEALING LEAKAGESITES AT THE AIRHANDLER'SREMOVABLE ACCESSPANELS AND ATFILTER ACCESSPANELS.
SEAL COLLARSTO PLENUMWITH MASTICOR MASTICTAPE
USE REMOVABLE TAPE FOR FILTER DOOR
ALLOW 6" CLEARANCE ON ALL SIDES AND BETWEEN DUCT TAKE-OFFS FROM PLENUM
SEAL ALL JOINTSAND SEAMS IN AIRHANDLER ANDDUCTWORK WITHMASTIC OR MASTIC TAPE
ALL SUPPLYDUCT TAKE-OFFSSHALL BESPACED ATLEAST 6 INCHESAPART FROMEACH OTHERWITH NO DUCTTAKE-OFFSORIGINATINGFROM THE CAPOF THE SUPPLYPLENUM.JUNCTION BOXESWITH 4TAKE-OFFS ORLESS AREEXCLUDED.
5' MAXIMUM
SAG 1/2" PER FOOTOF SUPPORT SPACING
ALL DUCT WORK SHALL BE MADE OF RIGID DUCTMATERIALS (SHEET MATERIAL OR DUCT BOARD) ORALL FLEX DUCT SHALL BE PULLED TIGHT FOR OPTIMAL AIR FLOW WITH NO PINCHES OR KINKS.
ADVANCED LADDER T-WALL FRAMING
VALLEY FLASHING
ALL VALLEYS ANDPENETRATIONS IN THE ROOFINGSYSTEM SHALL BE REINFORCED WITH EITHER METAL FLASHINGMATERIAL OR ASELF ADHERINGUNDERLAYMENTDESIGNED ANDAPPROVED FORUSE WITH THEINSTALLEDROOFING SYSTEM.
WINDOW PAN FLASHING UNITS
ALL WINDOWS AND EXTERIOR DOORS SHALL HAVE A WATER RESISTANT FLASHING INSTALLED ON THE SIDE AND BASE OF WINDOW AND DOOR ROUGH OPENINGS TO DIRECT WATER LEAKS OUT OF THE FRAMING.
GUTTERSCONNECTED TODOWNSPOUTSTHAT DRAINWATER AWAYFROM THE HOUSE
DURABLE ROOFWITH OVERHANG ALL RAIN FROM
THE ROOF SHALLBE COLLECTED INA ROOF GUTTERSYSTEM ANDDIRECTED VIADOWNSPOUTS SUCH THAT WATER ISDISCHARGEDATLEAST 5 FEETAWAY FROM THEFOUNDATION.GUTTERS ANDDOWNSPOUTS THAT DRAIN WATER TO THE BASE OF THEFOUNDATION ARENOT ELIGIBLE FORTHESE CREDITS.
HEAT TRAP
CUT-OUTSFORHEATING COILELEMENTS
REQUIRED: ALL FIXTURES MUST MEET NATIONAL ENERGY POLICY ACT FLOW STANDARDS.REQUIRED: HEAT TRAPS INSTALLED ON ALL WATER HEATERS.
INTERIOR
EXTERIOR
INSULATIONBATT
WINDOW ROUGH OPENING
FILTER AT RETURNAIR PLENUM FORFRESH AIR
SUPPLY AIR DUCTRETURN AIR DUCT
FRESH AIR INTAKE
RETURN AIR PLENUM
SCALE:1
EC101DETAIL
NOT TO SCALE SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE: SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE: SCALE: SCALE:
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
EC101
EARTHCRAFTDETAILS
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
D D D
WWWWH
DW
A2011
A2021
A2022
A2012
2' - 0" 8' - 0" 9' - 11" 16' - 0" 20' - 0 1/4" 10' - 0"
36' -
0 1
/4"
12' -
0"
9' -
11"
8' -
0"2'
- 0"
2' - 0"1' - 11 3/4" 25' - 11 1/2" 5' - 11 3/4" 30' - 0 1/4"
2' -
0"1'
- 11
3/4
"6'
- 0"
15' -
11
1/2"
5' -
11 3
/4"
36' -
0 1
/4"
RECEPTION3
WORK ROOM4
CONF ROOM5
FILES6
MECH/ELC7STORAGE
8
873 SF
COMMUNITYROOM
1
KITCHENETTE2
CORRIDOR9
MECH/JANITORCLOSET
10
H/C WOMEN'STOILET
11
H/C MEN'S TOILET12
LAUNDRY13
FITNESS14
VESTIBULE16
1A302
2A301
1A301
A602
1
A801
A
67' -
11
1/4"
65' - 11 1/4"
67' -
11
1/4"
2' -
9 1/
2"
1' - 4"
14
13
5
9
10
11
6
7
8
CC
S
S
CC
CC S S S
S
CC
36' -
0 1
/4"
5' -
5 1/
2"6'
- 6
3/4"
6' -
5 1/
2"3'
- 5
1/2"
4' -
6 3/
4"3'
- 5
1/2"
2' -
0"
5' - 11 3/4" 4' - 10 1/2" 10' - 0 1/4" 10' - 0 1/4" 5' - 1 1/2"
4' -
5 3/
4"6'
- 10
"13
' - 8
"6'
- 10
"4'
- 2
1/2"
5' -
11 3
/4"
3' -
10 3
/4"
12' -
0 3
/4"
3' - 5 1/2" 4' - 6 3/4" 9' - 11" 11' - 3 3/4" 8' - 8 1/2"
5 1/2"1' - 6 1/2" 5 1/2"
7' - 6 1/2"5 1/2"
9' - 0"5 1/2"
15' - 6 1/2"5 1/2"
6' - 7 1/2"3 1/2"
6' - 7"3 1/2"
5' - 11 1/4"3 1/2"
9' - 8 1/2"3 1/2"
1' -
11 3
/4"
3 1/
2"5'
- 8
1/2"
3 1/
2"15
' - 4
1/2
"3
1/2"
5' -
6 1/
4"5
1/2"
15' -
6"
3 1/
2"5'
- 1"
3 1/
2"14
' - 6
3/4
"3
1/2"
5 1/2"1' - 6 1/2"
5 1/2"1' - 6 1/4"
3 1/2" 25' - 4 1/2"3 1/2"
5' - 6 1/4"5 1/2"
19' - 8 3/4"3 1/2"
9' - 8 1/2"3 1/2"
3 1/
2"14
' - 6
3/4
"3
1/2"
6' -
7"5
1/2"
6' -
7"3
1/2"
6' -
11 1
/2"
5 1/
2"11
' - 6
1/2
"5
1/2"
9' -
0"5
1/2"
8' -
0"
AHU
B
A8011
2
36"W x 48"H SERVICE WINDOW, SILL@ 2' - 10"
8' -
0"
10' - 0"
MAINT SHOP15
2A302
A602
3
SEE CIVIL
F
A801
C
D
C
C1
C1
C1
C
C1
C1
C1
D
D1
A2023
HP-1HP-2
HP-2
FEC
SHOP SINK
FEC
F
F
C
C1
C1
C1
-
16
8' - 9 1/2"
S
S
UU
UU
S
EXPANSION JOINT COVER
7' - 6 3/4"
3 1/2"CLEAR
5' - 0"
1
1
11' - 11 3/4"
AHU AHU
DS, CONNECT TO U/G. TYP1
4
3
2
1512
BACKFLOW PREVENTION, SEE P101
F.D.
C.D.
F.D.
F.D.
A
D
E
C
C1
D1
1/2" GWB
2X6 STUDS @ 16" OC
R-21 BATTS
1" SIS
BRICK VENEER OR 4" BLOCK EXPOSED (RM'S 7 & 11 ONLY)
AIR SPACE
BRICK TIES@16" OC VERT, TYP
2X4 WOOD STUDS @ 16" OC
5/8" GWB
ABOVE W/R-15ACOUSTIC BATTS
ABOVE W/TOW@48" AFF (NO INSUL)
2X6 WD. STUDS @ 16" OC
5/8" GWB
R-21 ACOUSTIC BATTS
THINSET CT ON 1/2" CEMENT BOARD
2X6 WD STUDS @ 16" OC
B
5/8" GWB
2X6 @ 16" OC
R-21 BATTS
AIR SPACE
4" BLOCK (BRICK ABOVE)
5/8" GWB
1/2" RC
F
10 1/4"
1/2" GWB
2X4 STUDS @ 16" O.C.
R-13 BATTS
1" SIS
BRICK VENEER
AIR SPACE
BRICK TIES@16" OC VERT, TYP
9 1/2"
11 1/2"
MASONRY TIES@16" OC VERT, TYP
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A101
FLOOR PLANAND WALLTYPES
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/4" = 1'-0"A1011 COMMUNITY BUILDING FLOOR PLAN
3/4" = 1'-0"WALL TYPES
NOTE: COORDINATE HEAT PUMP PADS WITH GRADING PLAN TO AVOID PONDING. PAD SIZE = UNIT DIMENSION + 6" EA SIDE. SEE DETAIL, SHT M501
DS SEE CIVIL FOR CON'T (TYP)
HOSE BIB
1A302
2A301
1A301
+ 9' - 0"
+ 8' - 0"
+ 9' - 0" + 9' - 0" + 8' - 0"
+ 9' - 0"
+ 8' - 0"
+ 8' - 0"+ 8' - 0"
+ 7' - 8"
+ 8' - 0"
+ 8' - 0"
+ 9' - 0"
2A302
+ 9' - 0"
SURF MOUNTED 1x4 LED
LAY IN 2X2
(1) CAN @EWC
LAY-IN 2X2
CANS, SEPERATE SWITCH
SURF MOUNTED2X2
+11' - 111/2"
+ 9' - 0"
+ 9' - 0"
REQ
UIR
ED
WID
TH A
S
1
1
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A151
REFLECTEDCEILING PLAN
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/4" = 1'-0"A1511 FIRST FLOOR
1 3/15/17 BO COMMENTS
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
2A301
TRUSS BEARING 116' - 0"
TRUSS BEARING 212' - 0"
6
126
12
6
12
SS S
2A302
ALUM GUTTER OVER FCB FASCIA
5/4" X 3 1/2" FCB WINDOW TRIM, SEE DETAIL
RUNNING BOND MODULAR FACE BRICK, TYP
BRICK WATER TABLE
HIPPED CANOPY OVER ENTRY
BUILDING MOUNTED LIGHT FIXTURE, SEE ELEC
THIS FIXTURE W/BATTERY BACKUP FOR EMERGENCY EGRESS
A2013
6
12
DOWNSPOUT BOOT - CONNECT TO DRAINAGE SYSTEM RE: CIVIL DWGS
RIDGE VENT
S S S2
15
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
1A301
TRUSS BEARING 116' - 0"
TRUSS BEARING 212' - 0"
6
126
12
CC
FIBER CEMENT BOARD SIDING W/6" EXPOSURE, TYP
5/4 X 3 1/2" FCB TRIM, TYP
BRICK SOLDIER COURSE, TYP
BUILDING MOUNTED LIGHT FIXTURE, SEE ELEC
THIS FIXTURE W/BATTERY BACKUP FOR EMERGENCY EGRESS
FIBERGLASS SHINGLES OVER CONTINUOUS ICE & WATER SHIELD, TYP
RIDGE VENT
HOSE BIBB
DOWNSPOUT BOOT - CONNECT TO DRAINAGE SYSTEM RE: CIVIL DWGS
ROOF VENT, SEE MECH
71 ROWLOCK SILL, TYP
HEAD
5/4" X 3 1/2" CEDARMILL FCB TIM, TYP
JAMB
TYP
1 1/2"
FACE BRICK
PRE-MOLDED FOAM PAD
SEALANT W/ BACKER ROD
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A201
CLUBHOUSEEXTERIORELEVATIONSNORTH & EAST
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/4" = 1'-0"A2011 East
1/4" = 1'-0"A2012 North
GENERAL NOTES-EXTERIO BUILDING ELEVATIONS
1. PROVIDE POSITIVE GRADING AROUND BUILDING PERIMETER EXTENDING AMINIMUM OF 10 FEET FROM BUILDING. SLOPE GRADE UNIFORMLY TO DROP INLETSAND YARD SWALES, COORDINATE GRADING AND DRAINAGE WITH OUTDOOREQUIPMENT TO ENSURE POSITIVE DRAINAGE. DO NOT GRADE ABOVE BRICK WEEPHOLES.
2. ALL DOWNSPOUTS TO BE CONNECTED TO UNDERGROUND DRAINAGE SYSTEM.PROVIDE CASTIRON BOOT AT EACH DOWNSPOUT.
3. PREVENT DRAINAGE FLOW ACROSS SIDEWALKS AND OTHER IMPERVIOUSSURFACES.
4. CONDENSATE DRAINS AND COOLANT LINES ARE TO BE CONCEALED WITHIN THEWALL, CEILING OR FLOOR SYSTEM.
5. NO EXPOSED CONDUITS ON EXTERIOR OF BUILDING.6. PAINT DOORS AND TRIM.7. PAINT FCB SIDING AND TRIM. (OR PRE-FINISHED, CONTRACTOR'S OPTION)8. PAINT VENTS AND LOUVERS.9. INSTALL MOUNTING BLOCKS FOR ALL PENETRATIONS IN SIDING SUCH AS
ELECTRICAL, PLUMBING, HVAC, AND DUCTWORK, ECT. MATCH EXTERIOR MATERIALCOLOR.
10. POWER WASH/CLEAN EXTERIOR BRICK.
3" = 1'-0"A2013 WINDOW FCB TRIM DETAIL
3" = 1'-0"A2014 BRICK CONTROL JOINT
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
1A301
TRUSS BEARING 212' - 0"
6
12
6
12
S S S
EMERGENCY LIGHT W/BATTERY BACKUP, TYP OF 2
ALUM GUTTER OVER FCB FASCIA
50 YEAR FIBERGLASS SHINGLES OVER CONTINUOUS ICE & WATER SHIELD, TYP
CONTINUOUS RIDGE VENT
FIBER CEMENT BOARD SIDING W/6" EXPOSURE, TYP
RUNNING BOND MODULAR FACE BRICK, TYP
6
12
DOWNSPOUT BOOT - CONNECT TO DRAINAGE SYSTEM RE: CIVIL DWGS
BUILDING MOUNTED LIGHT FIXTURE, SEE ELEC
HOSE BIBB
5/4 X 3 1/2" FCB TRIM, TYP
BRICK ROWLOCK
APPROX FINISH GRADE
FCB WRAPPED BRACE @ CANOPY
CONCRETE SLAB ON GRADE
RIDGE VENT
5/4 X 7 1/2" FCB TRIM
16
LOUVERS, SEE MECH.
2
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
2A301
TRUSS BEARING 212' - 0"
4"
6
12
CCCC CC
2A302
RUNNING BOND MODULAR FACE BRICK, TYP
FIBER CEMENT BOARD SIDING W/6" EXPOSURE, TYP
50 YEAR FIBERGLASS SHINGLES OVER CONTINUOUS ICE & WATER SHIELD, TYP
DOWNSPOUT BOOT - CONNECT TO DRAINAGE SYSTEM RE: CIVIL DWGS
2' -
0"
7' -
6"
CC
GRADE
BRICK ROWLOCK
5/4 X 7 1/2" FCB TRIM
ALUMINUM GUTTER AND DOWNSPOUT (TYP)
5/4 X 3 1/2" FCB TRIMROWLOCK SILL @ WINDOWS
SOLDIER COURSE @ WINDOW HEAD
CONTINUOUS RIDGE VENT
50 YEAR FIBERGLASS SHINGLES OVER CONTINUOUS ICE & WATER SHIELD, TYP
UU UU 5/4 X 3 1/2" FCB TRIM @ CORNER, TYP
ROOF VENT, SEE MECH
OA INTAKE LOUVER
1A302
HIP OF ROOF ABOVE
VALLEY
ALUM GUTTER OVER FCB FASCIA
SMOOTH FCB PANEL,PAINTED
3/4 X 7 1/2" FCB TRIM
5/4 X 2 1/2" FCB TRIM, TYP @ THIS OPENING
FCB BOARD SIDING W/6" EXPOSURE, TYP
5/4 X 3 1/2" FCB TRIM
BRICK ROWLOCK
RUNNING BOND MODULAR FACE BICK
4" SLAB ON GRADE
DOWNSPOUT BOOT CONNECT TO DRAINAGE SYSTEM. RE: CIVIL
VALLEY
S S2
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A202
CLUBHOUSEEXTERIORELEVATIONSSOUTH & WEST
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/4" = 1'-0"A2021 South
1/4" = 1'-0"A2022 West
GENERAL NOTES-EXTERIO BUILDING ELEVATIONS
1. PROVIDE POSITIVE GRADING AROUND BUILDING PERIMETER EXTENDING AMINIMUM OF 10 FEET FROM BUILDING. SLOPE GRADE UNIFORMLY TO DROP INLETSAND YARD SWALES, COORDINATE GRADING AND DRAINAGE WITH OUTDOOREQUIPMENT TO ENSURE POSITIVE DRAINAGE. DO NOT GRADE ABOVE BRICK WEEPHOLES.
2. ALL DOWNSPOUTS TO BE CONNECTED TO UNDERGROUND DRAINAGE SYSTEM.PROVIDE CASTIRON BOOT AT EACH DOWNSPOUT.
3. PREVENT DRAINAGE FLOW ACROSS SIDEWALKS AND OTHER IMPERVIOUSSURFACES.
4. CONDENSATE DRAINS AND COOLANT LINES ARE TO BE CONCEALED WITHIN THEWALL, CEILING OR FLOOR SYSTEM.
5. NO EXPOSED CONDUITS ON EXTERIOR OF BUILDING.6. PAINT DOORS AND TRIM.7. PAINT FCB SIDING AND TRIM. (OR PRE-FINISHED, CONTRACTOR'S OPTION)8. PAINT VENTS AND LOUVERS.9. INSTALL MOUNTING BLOCKS FOR ALL PENETRATIONS IN SIDING SUCH AS
ELECTRICAL, PLUMBING, HVAC, AND DUCTWORK, ECT. MATCH EXTERIOR MATERIALCOLOR.
10. POWER WASH/CLEAN EXTERIOR BRICK.
1/4" = 1'-0"A2023 ENTRY ELEVATION
4" SLAB ON GRADE, SLOPE TO DRAIN (2% MAX)
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
Top of Footing-1' - 4"
2A301
TRUSS BEARING 212' - 0"
2A302
COMMUNITYROOM
1
CORRIDOR9
MAINT SHOP15
F.C. SIDING (TYP) ON AIR BARRIER
1 " SIP
2X4's @ 16" OC W/R-19 BATTS
BRICK WATER TABLE
RUNNING BOND MODULAR BRICK, TYP
1/2" GWB TYP
12" CMU
PRE - ENGINERED WOOD TRUSS
DUCTWORK,SEE MECH
6
12 R-38 BLOWN CELLULOSE INSULATION, TYP
PERFORATED VINYL SOFFIT
WH
SHOP SINKSEALED CONC FLOOR SLAB
4" CONC SLAB ON GRADE
DOORBEYOND
1 1
PAINTED GWB, TYP
LUXURY VINYL PLANK FLOORING
ACT @ 8'-0" AFF W/LAY-IN LIGHING FIXTURES
DOOR
CONTINUOUS RIDGE VENT
50--YEAR FIBERGLASS SHINGLES OVER ICE/WATER SHEILD ON ROOF SHEATING
1/2" GWB @ BOTTOM CHORD
DRYWALL CONTROL JOINT COVER
EWC W/BOTTLE FILL
SA15 - 125 EXPANSION JOINT COVER
COFFERED CEILING, SEE RCP
36" X 40" H SEVICE WINDOW
WOOD SILL @ 2'-10" AFF
FEC
8
16" X 16" RETURN AIR GRILL
PERF VINYL SOFFIT
RUNNING BOND MODULAR FACE BRICK
SOLDIER COURSE
ALUMINUM GUTTER & DOWNSPOUT
DOWNSPOUT BOOT
CONC SLAB ON GRADE
DOOR
FOUNDATION, SEE STRUCT
6" MIN #57 STONE
1/2" EJ
2" (R-10 MIN) RIGID POLYISO
FOUNDATION, SEE STRUCT6" MIN #57 STONE
4" CONC SLAB ON GRADE
1/2" EJ
2" (R-10 MIN) RIGID POLYISO
R-38 BLOWN CELLULOSE INSULATION, TYP
1/2" EJ
PRE-ENGINEERED WOOD TRUSSES W/ENERGY HEEL@24" OC MAX
3
1' - 0"
1' - 0"
6
12
11
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
Top of Footing-1' - 4"
1A301
TRUSS BEARING 212' - 0"
4' -
0"
COMMUNITYROOM
1
CONF ROOM5RECEPTION
3
50-YEAR FIBERGLASS SHINGLES, OVER ICE/WATER SHIELD ON ROOF SHTHG
PRE-ENGINEERED ROOF TRUSSES W/ENERGY HEEL @24" OC MAX
R-38 BLOWN CELULOSE INSULATION, TYP
6
12
6
12
CONTINUOUS RIDGE VENT
LAY-IN 2X2 ACOUSTIC CEILING
1/2" GWB @ BOTTOM CHORD. FINISH LEVEL 1
1X8 WOOD CAP
36"W X 48"H SERVICE WINDOW
SEMI-RECESSED FEC BEYOND. MOUNT @ 48" MAX AFF TO OPERABLE HANDLE
5/8" GWB ON 7/8" HAT CHANNELS
2' -
10"
6
PAINTED GWB
FOUNDATION, SEE STRUCT
2" (R-10 MIN) RIGID POLYISO
1
1/2" EJ
DUCTWORK,SEE MECH
DUCTWORK,SEE MECH
1/2" GWB@BOTTOM CHORD, CON'T. FINISH LEVEL 1
BASE AS SCHEDULED
CONNECT ALL DS TO U/G DRAINAGE SYSTEM
SLOPE 5% MIN.
8"
8"8"
6
12
1' - 0"
1 1
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A301
BUILDINGSECTIONS
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
3/8" = 1'-0"A3011 Section 3
3/8" = 1'-0"A3012 Section 2
1 3/15/17 BO COMMENTS
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
Top of Footing-1' - 4"
TRUSS BEARING 212' - 0"
50-YEAR FIBERGLASS SHINGLES ON ICE & WATER SHIELD
FCB FASCIA
ALUMINUM GUTTER
PERFORATED VINYL SOFFIT PANELS
FCB SIDING BEYOND
BRICK ROWLOCK
ALUMINUM DOWNSPOUT
DOWNSPOUT BOOT
5/4 X 7 1/2" FCB TRIM
1/4" SMOOTH FC PANEL, PAINTED
1" SIS, CONTINUOUS
5/4 X 5 1/2" FCB TRIM
1/2" GWB, FINISH LEVEL 1
2X6 WD STUDS @16" OC W/R-13 BLOWN CELLULOSE INSULATION
(3) 2X8'S W/ 1/2" POLYISO SANDWICHED
SERVICE WINDOW BEYOND
WOOD STOOL
WOOD CASING @ FACE OF WALL
R-38 BLOWN CELLULOSE
FOUNDATION W1, SEE STRUCT
6" MIN #57 STONE
4" CONC SLAB ON GRADE
1/2" EJ
2" (R-10 min) RIGID POLYISO
WOOD BASE BEYOND
VCT
SLOPE TO DRAIN
ACCESSIBLE THRESHOLD
10 MIL VAPOR BARRIER, TYP
AIR INFILTRATION BARRIER
5/4 FASCIA
1' - 1 1/4"
1
WEEP HOLES (ROPEWICK) @ 2' - 8" OC
4" DIA. PERFORATED PERIMETER DRAIN TILE W/ FILTER FABRIC - CONT. SET IN CLEAN GRAVEL BACKFILL - CONNECT TO OUTFALL
SEALANT - TYP
4
12
6
12
FIRST FLOOR0' - 0"
TRUSS BEARING 39' - 0"
Top of Footing-1' - 4"
TRUSS BEARING 212' - 0"
6" MIN #57 STONE
4" CONC SLAB ON GRADE
1/2" EJ
FOUNDATION W1, SEE STRUCT
6" MIN #57 STONE
4" CONC SLAB ON GRADE
2" RIGID POLYISO (R-10 MIN)
WEEP HOLES (ROPEWICK) @ 2' - 8" OC
RUNNING BOND MODULAR FACE BRICK
ROWLOCK COURSE
FCB SIDING W/6" EXPOSURE ON AIR BARRIER
2 X4'S @16" OC W/R-13 BLOWN CELLULOSE INSULATION
1" SIS, CONT
1 X 4 WOOD BASE, PAINTED
SEE FINISH SCHEDULE
SLOPE TO DRAIN
GALV WALL TIES @ 16" OC VERT AND 32" OC HORIZ (STAGGERED - TYP)
ALUM GUTTER
PERF VINYL SOFFIT
PAINTED GWB
WOOD DOOR CASING, PAINTED
1/2" GWB CEILING
PAINTED GWB
PRE-ENGINEERED WOOD TRUSS
INSULATION BAFFLE
R-38 BLOWN CELLULOSE INSULATION
WD BLOCKING
2X WD SUBFASCIA
14
1X FCB FASCIA
10 MIL VAPOR BARRIER, TYP
1' - 1 1/4" 1
FLEXIBLE THROUGH WALL FLASHING -STOP 1/2" FROM FACE OF BRICK
4" DIA. PERFORATED PERIMETER DRAIN TILE W/ FILTER FABRIC -
CONT. SET IN CLEAN GRAVEL BACKFILL - CONNECT TO OUTFALL
AIR INFILTRATION BARRIER
SEALANT - TYP
SEALANT - TYP
SEALANT - TYP
VINYL WINDOW UNIT - SEE WINDOW SCHEDULE
AIR BARRIER
1" SIS, CONT
FLAS
HIN
G
8" M
IN
6
12
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A302
WALLSECTIONS
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
3/4" = 1'-0"A3021 PARTIAL WALL SECTION 1 3/4" = 1'-0"A302
2 PARTIAL WALL SECTION 2
1 3/15/17 BO COMMENTS
FLUSH WD PR FLUSH WD WD HG PR HM INSUL HM INSUL FG SF
A B C D E F
WD STUDSGWBSEALANT - TYP
WD TRIM - TYP
WD JAMB - TYPDOOR - SEE DOOR SCHEDULE
5/8" GWB
DOOR - SEE DOOR SCHEDULE
INTERIOR EXTERIOR
AIR INFILTRATION BARRIER OVER 1" SIS
FRAME5 3/4" H.M.
F.C. TRIM
1" SIS
SEALANT AND BACKER RODSEAL CAVITY W/ ROCK WOOL INSULATION PRIOR TO PLACING BACKING ROD
2"
(1 HR BEARING ASSEMBLY)
UL U305
SEALANT - TYPSEALANT
1x WD TRIM, PAINTED
DOOR - SEE DOOR SCHEDULE
HEADER PER STRUCTURAL5/8" GWB - TYP
FIBER CEMENT SIDING
TAPE OVER DRIP CAP
METAL FLASHING
AIR INFILTRATION BARRIER OVER 1" SIS
3 1/2" F.C. TRIM
SEALANT
NON-EXPANDING FOAM INSUL SEALANT
WD BLOCKING
INTERIOR EXTERIOR
GWB
WD STUDS
SEALANT - TYP
HEADER - SEE STRUCT.
WD TRIM - TYP
DOOR - SEE DOOR SCHEDULEJAMB BEYOND
WD BLOCKING
ANCHORS - 3 PER JAMB
SEALANT
SEALANT - TYP
HM FRAME, PAINTED
DOOR - SEE DOOR SCHEDULE
SEALANT - TYPFACE BRICK, RETURN @ JAMB - TYP
INTERIOR EXTERIOR
AIR INFILTRATION BARRIER OVER 1" SIS
1 1/2"
2"D
LOD
OO
R
4 1/2" ALUMINUM STOREFRONT HEAD W/INTEGRAL STOP
DOOR STILE
TRANSOM GLAZING STOPS
1" INSULATEDGLAZING
4 1/2"
5/8" GWB
2X HEADER
ALUMINUM STOREFRONT WINDOW SYSTEM
5/8" GWB
ALUMINUM STOREFRONT FRAME
1" INSUL. GLAZING BRICK VENEER
1" STRUCTURALLY INSULATED SHEATHING
4 1/
2"3"
2"
RETURN FACE BRICK
SEALANT AND BACKER ROD
SEALANT AND BACKER ROD
1
ALUMINUM STOREFRONT WINDOW SYSTEM
4 1/2" 5 1/2"WRAP GYP @JAMB (BEYOND)
BASE AS SPECIFIED
SEE FINISH SCHEDULE RETURN FACE BRICK
@ JAMB BEYOND
5/4 X 5 1/2" FCB TRIM, TYP @ THIS OPENING
2" RIGID POLYISO (R-10 MIN)
ALUMINUM STOREFRONT WINDOW SYSTEM
5/4 X 5 1/2" FIBER CEMENT BOARD TRIM
1" STRUCTURALLY INSULATED SHEATHING
1/4" SMOOTH FIBER CEMENT BOARD PANEL
FLASHING
4 1/2"
AIR INFILTRATION BARRIER
5 1/2"
WRAP GYP @JAMB (BEYOND)
RETURN FACE BRICK @ JAMB BEYOND
SEALANT AND BACKER ROD
ALUMINUM STOREFRONT SYSTEM
1" STRUCTURALLY INSULATED SHEATHING
SOLDIER COURSE
FLASHING
4 1/2" 5 1/2"
SHELF ANGLE, SEE STRUCT
RETURN FACE BRICK @ JAMB BEYOND
1/2"
SEALANT AND BACKER ROD
ALUMINUM STOREFRONT WINDOW SYSTEM
FIBER CEMENT BOARD TRIM
1" SIS
FIBER CEMENT BOARD SIDING
FLASHING
4 1/2"
WD STUDSGWBSEALANT - TYP
WD TRIM - TYP
WD JAMB - TYPDOOR - SEE DOOR SCHEDULE
1/2" GWB
ALUMINUM STOREFRONT FRAME
1" INSUL. GLAZING
1" SIS
ROW LOCK BELOW
4 1/
2"5
3/4"
2"
5/4 X 3 1/2" FCB TRIM
FCB SIDING
SEALANT AND BACKER ROD
SEALANT AND BACKER ROD
1
1/2" EJ
NGP 8633, THRESHOLD WITH THERMAL BREAK
4 1/2" 5 1/2"
DAMPPROOFING AS SPECIFIED IN 071113, TYP.
WRAP GYP @JAMB (BEYOND)
BASE AS SPECIFIED
SEE FINISH SCHEDULE
RETURN FACE BRICK @ JAMB BEYOND
2" RIGID POLYISO (R-10 MIN)
1' - 0 3/4"
SLOPE 2% MAX
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A601
FINISHSCHEDULE,DOORSCHEDULES,AND DETAILS
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
DOOR SCHEDULE
DO
OR
NO
.ROOM NAME Q
UAN
TITY
FIR
E R
ATIN
G
DOOR SIZE
DOOR MATERIAL DOOR FINISH ELEV HEAD
DTL JAM
B D
TL
CLO
SER
WEA
THER
STR
IPPI
NG
HAR
DW
ARE
SETS
REMARKSWidth Height Thickness1 COMMUNITY ROOM
ENTRY1 - 3' - 0" 6' - 5 1/2" 1 3/4" ALUM. SF. ANODIZED F 2 5 ● ● 1* *DETAIL 7 @ SIDELIGHT, DETAIL 10 @ SILL
2 ENTRY 1 3' - 0" 7' - 0" 1 3/4" ALUM. SF. ANODIZED F 4, 1 5 ● ● 1* *DETAIL 10@ SILL3 RECEPTION 1 3' - 0" 7' - 0" 1 3/4" ALUM. SF. ANODIZED F 8 9 ● ● 1*4 CORRIDOR 1 3' - 0" 7' - 0" 1 3/4" ALUM. SF. ANODIZED F 8 9 ● ● 1*5 CONF. RM. 1 - 3' - 0" 6' - 8" 1 3/4" WD STAIN A 11 13 ● 26 FILES 1 - 3' - 0" 6' - 8" 1 3/4" WD STAIN A 11 13 ● 47 ELEC. 1 - 3' - 0" 7' - 0" 1 3/4" HM. INSUL. PAINT E 12 14 ● ● 58 STORAGE 2 - 6' - 0" 6' - 8" 1 3/4" WD STAIN B 11 13 69 MECH. 1 - 3' - 0" 6' - 8" 1 3/4" WD STAIN A 11 13 ● ● 410 WOMEN'S 1 - 3' - 0" 6' - 8" 1 3/4" WD STAIN A 11 13 ● 711 MEN'S 1 - 3' - 0" 6' - 8" 1 3/4" WD STAIN A 11 13 ● 712 CORRIDOR 1 3' - 0" 6' - 8" 1 3/4" WD STAIN C 11 13 ● ● 313 LAUNDRY 1 45 3' - 0" 6' - 8" 1 3/4" WD STAIN C 11 13 ● ● 2 45 MIN. FIRE RATED DOOR (GLAZING)14 FITNESS 1 - 3' - 0" 6' - 8" 1 3/4" WD STAIN C 11 13 ● ● 215 VESTIBULE ENTRY 1 3' - 0" 7' - 0" 1 3/4" ALUM. SF. ANODIZED F 3 6 ● ● 1* *DETAIL 10@ SILL16 MAINT. 2 - 6' - 0" 6' - 8" 1 3/4" I.H.M. PAINT D 12 14 ● ● 8
FINISH SCHEDULE
WT NAME
ROOMCEILINGHEIGHT REMARKSBASE FINISH
FLOORFINISH
WALLFINISH
CEILINGFINISH
1 COMMUNITY ROOM WD LVT GWB GWB VARIES2 KITCHENETTE WD LVT GWB GWB 8'-0"3 RECEPTION WD CPT GWB ACT 9'-0"4 WORK ROOM WD CPT GWB ACT 9'-0"5 CONF ROOM WD CPT GWB GWB 9'-0"6 FILES WD CPT GWB GWB 8'-0"7 MECH/ELC RUBBER S. CONC MRGWB MRGWB 9'-0"8 STORAGE RUBBER VCT GWB GWB 9'-6"9 CORRIDOR WD VCT GWB ACT 8'-0" GWB CL'G@EWC10 MECH/JANITOR CLOSET RUBBER S. CONC MRGWB MRGWB 9'-0"11 H/C WOMEN'S TOILET RUBBER VCT MRGWB MRGWB WT12 H/C MEN'S TOILET RUBBER VCT MRGWB MRGWB 8'-0"13 LAUNDRY WD VCT GWB GWB 9'-0"14 FITNESS WD LVT GWB GWB 9'-0"15 MAINT SHOP RUBBER S. CONC MRGWB MRGWB 9'-0"16 VESTIBULE WD VCT GWB ACT 8'-0"
1/4" = 1'-0"DOOR ELEVATIONS
1 1/2" = 1'-0"A60113 INTERIOR DOOR JAMB DETAIL
1 1/2" = 1'-0"A60115 JAMB DETAIL@ F.C. SIDING - HEAD SIM
1 1/2" = 1'-0"A60112 EXTERIOR DOOR HEAD DTL@ F.C. SIDING
1 1/2" = 1'-0"A60111 INTERIOR DOOR HEAD DTL
1 1/2" = 1'-0"A60114 EXTERIOR DOOR JAMB DTL @ BRICK
1 1/2" = 1'-0"A6014 STORE FRONT HEAD DETAIL AT TRANSOM
1 1/2" = 1'-0"A6018 STORE FRONT INTERIOR HEAD DETAIL
1 1/2" = 1'-0"A6015 STORE FRONT JAMB DETAIL AT BRICK
1 1/2" = 1'-0"A6017 STORE FRONT SILL AT SIDELIGHT
1 1/2" = 1'-0"A6011 STORE FRONT TRANSOM HEAD DETAIL AT FCB PANEL
1 1/2" = 1'-0"A6012 STORE FRONT HEAD DETAIL AT BRICK
1 1/2" = 1'-0"A6013 STORE FRONT HEAD DETAIL AT FCB SIDING
1 1/2" = 1'-0"A6019 STORE FRONT INTERIOR DOOR JAMB DETAIL
1 1/2" = 1'-0"A6016 STORE FRONT JAMB DETAIL AT FCB SIDING
1 1/2" = 1'-0"A60110 STORE FRONT SILL AT CONCRETE JOINT
1 3/15/17 BO COMMENTS
WRAP LAMINATE AT ALL EXPOSED EDGES
REFDW
P-LAM TOP & BACKSPLASH
3' - 0"
FILLER PANEL
2' -
6"
BULKHEAD
FILLER PANEL
4
RIM
OF
SIN
K
2' -
10" M
AX T
O
1
9' -
0"
8' - 9 1/4"4" KICKPLATE W/RUBBER BASE
3' -
6"
MTL SUPPORT BRKT, TYP OF 4
MTL SUPPORT BRKT, TYP OF 2
P-LAM COUNTERTOP
H/C MICROWAVE
ADJUSTABLE SHELF
WRAP LAMINATE AT ALL EXPOSED EDGES4
A602
REF
P-LAM COUNTERTOP
MTL SUPPORT BRKT, TYP OF 4
MTL SUPPORT BRKT, TYP OF 2
P-LAM BASE CABINET W/ 1X4 WOOD BASE
4A602
MTL SUPPORT BRACKET, TYP OF (4)
BASE CABINET W/ADJUSTABLE SHELF. P-LAM @ ALL EXPOSED SURFACES.
2' -
10"
3' -
6"
CC
P-LAM COUNTERTOP AND BACKSPLASH
BOTTOM CHORD OF TRUSS
(INSUL NOT SHOWN FOR CLARITY)
2X FRAMING AS REQUIRED
1/2" GWB, TYP @ BULKHEAD ONLY
1/2" HAT CHANNELS
5/8" TYPE 'C' GWB, CONTINUOUS WITHIN BULKHEAD
VAR
IES
WINDOW HEADER - SEE STRUCT
GWB PER WALL TYPE
SEALANT
SEALANT - TYPGWB JAMB - BEYOND
2x6 WD STUD W/ (R-19) BLOWN CELLULOSE INSULATION
VINYL WINDOW UNIT -SEE WINDOW SCHEDULE
NON-EXPANDING FOAM INSUL SEALANT
THROUGH WALL FLASHING -STOP 1/2" FROM FACE OF BRICK
SEALANT
FACE BRICK W/ MASONRY WALL TIES AT 32" HORIZONTALY AND 16" VERTICALY
STEEL LINTEL - SEE STRUCT
WEEP HOLES - ROPEWICK @ 2'-8" O.C.
BRICK SOLDIER COURSE
INTERIOR EXTERIOR
2x6 WD SILL
1/2" RIGID INSULATION
AIR INFILTRATION BARRIER OVER (R-5.5) 1" STRUCTURALLY INSULATED SHEATHING (SIS) PER MFR SPECS, TAPE SEAMS, TYP
FACE BRICK - BEYOND
GWB AT WINDOW HEAD
AIR CAVITY
FLEXIBLE MEMBRANE FLASHING
MTL DRIP EDGE, SEALANT BEHIND DRIP EDGE
VINYL WINDOW JAMB - BEYOND
0' - 0 3/4"
HEADER - SEE STRUCTURAL
5/8" GWB
RETURN GWB @ JAMBS
2x6 STUDS @ 16" O.C. W/ R-19 BLOWN CELLULOSE
VINYL WINDOW UNIT
NON-EXPANDING FOAM INSUL SEALANT
SEALANT
FLEXIBLE MEMBRANEFLASHING
FCB TRIM
METAL FLASHING
F.C. SIDING PER ELEVATIONS
AIR BARRIER
INTERIOR EXTERIOR
1" SIS
5/8" GWB
SEALANT - TYPWD SILL
VINYL WINDOW UNIT -RE: WINDOW SCHEDULE
NON-EXPANDING FOAM INSUL SEALANTSEALANTFLEXIBLE MEMBRANEFLASHING
SEALANT2x6 WD STUD W/ (R-19) BLOWN CELLULOSE INSUL
AIR INFILTRATION BARRIER OVER (R-5.5) 1" STRUCTURALLY INSULATED SHEATHING (SIS) PER MFR SPECS TAPE SEAMS, TYP
INTERIOR EXTERIOR
BRICK ROWLOCK - BELOW
FACE BRICK
5/8" GWB
SEALANT - TYPWD SILL - BELOW VINYL WINDOW UNIT
NON-EXPANDING FOAM INSUL SEALANTSEALANT
SIDING PER ELEVATIONSFCB TRIM - 3 1/2" x 5/4, TYP.FLEXIBLE MEMBRANE FLASHING
SEALANT2x6 WD STUD W/ (R-19) BLOWN CELLULOSE INSULATION
AIR INFILTRATION BARRIER OVER (R-5.5) 1" STRUCTURALLY INSULATED SHEATHING (SIS) PER MFR SPECS TAPE SEAMS, TYP
INTERIOR EXTERIOR
VINYL WINDOW UNIT
NON-EXPANDING FOAM INSUL SEALANT
SEALANT
5/8" GWB, PTD.
2x6 STUDS @ 16" O.C. W/ (R-19) BLOWN CELLULOSE
SEALANT
1x WD SILL, PAINTED
SEALANT, TYPRETURN GWB @ JAMBS
1x4 WD APRON, PAINTED
FLEXIBLE MEMBRANE FLASHING, STOP 1/2" FROM FACE OF BRICK
ROWLOCK COURSE, 3/4" MIN. SLOPETHROUGH WALL FLASHING - STOPS 1/2" FROM FACE OF BRICK
INTERIOR EXTERIOR
DOUBLE 2x6 WD SILL 0' - 0 1/2"MTL DRIP EDGE
SEALANT BEHIND DRIP EDGE
VINYL WINDOW UNIT
NON-EXPANDING FOAM INSUL SEALANT
SEALANT
5/8" GWB
2x4 WD STUD W/ (R-13) BLOWN CELLULOSE INSULATION
SEALANT3/4" WD SILL - PAINTED
SEALANT - TYP
JAMB - BEYOND
3/4"x4" WD APRON -PAINTED
F.C. SIDING PER ELEVATIONSFCB TRIM - 3 1/2" x 5/4", TYP.
SILL PAN FLASHING
AIR INFILTRATION BARRIER OVER (R-5.5) 1" STRUCTURALLY INSULATED SHEATHING (SIS), PER MFR SPECS TAPE SEAMS, TYP
INTERIOR EXTERIOR
VINYL WINDOW JAMB -BEYOND
SIDE DAM(END DAM)SIDEFLANGE
FRONTFLANGE
REAR LEG(BACK DAM)
FIGURE 2: SILL PAN FLASHING
SILLFLASHING
FIGURE 3: FLUSHWINDOW OPENING FLASHING
HEADFLASHING
WINDOW FRAMEAND SEALANT
JAMBFLASHING
FIGURE 1: OPENINGPREPARATION
BUILDING PAPER
FOLD SIDEANDBOTTOMSECTIONSTOWARDSBUILDINGINTERIOR
FOLD TOPSECTIONTOWARDSBUILDINGEXTERIOR
CUTTING PATTERN
FIGURE 4:FINISHED OPENING
FOLD TOPSECTIONTOWARDSBUILDINGINTERIOR
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A602
INTERIORELEVATIONS,WINDOWSCHED. ANDDETAILS
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/2" = 1'-0"A6021 KITCHENETTE A
1/2" = 1'-0"A6022 KITCHENETTE B
WINDOW SCHEDULE
WT DESCRIPTIONWINDOW SIZE
MATERIAL COMMENTSHEAD
DETAILSILL
DETAILJAMB
DETAILWIDTH HEIGHT1 3' - 0" 4' - 0"CC 3046M 3' - 0" 4' - 9 1/8" VINYL 6 10 8F SERVICE WIND. 3' - 0" 3' - 4" ALUM 1/4" GLAZINGS 3046M 3' - 0" 4' - 9 1/8" VINYL 7 10 9UU FIXED 3' - 0" 1' - 6" VINYL OBSCURED 7 11 9
1/2" = 1'-0"A6023 Elevation 1 - a
NOTE:1) BASIS OF DESIGN IS PLY-GEM 1500 SINGLE-HUNG, FLAT CASING W/ 7/8" DUAL GLAZED INSULATED GLASS W/LOW-E ON THIRD SURFACE & ARGON. EQUALS MAY BE ACCEPTED AFTER SUBMITTAL & REVIEW BY ARCHITECT2) VERIFY ROUGH OPENING DIMENSIONS WITH APPROVED MANUFACTURER AND IN FIELD.
1/2" = 1'-0"A6024 CASEWORK SECTION
1 1/2" = 1'-0"A6025 BULKHEAD DETAIL
1 1/2" = 1'-0"A6026 WINDOW HEAD @ BRICK
1 1/2" = 1'-0"A6027 WINDOW HEAD @ F.C. SIDING
1 1/2" = 1'-0"A6028 WINDOW JAMB @ BRICK
1 1/2" = 1'-0"A6029 WINDOW JAMB @ SIDING
1 1/2" = 1'-0"A60210 WINDOW SILL @ BRICK
1 1/2" = 1'-0"A60211 WINDOW SILL @ F.C SIDING
1 3/15/17 BO COMMENTS
1/4" = 1'-0"A60212 WINDOW FLASHING
A801
A
B
H/C WOMEN'STOILET
11
H/C MEN'S TOILET12
A801
C
D
P-1 WATER CLOSET
LAV.
7
5
6
1
4
3
2
3 65
7
4
2
1
P-1 WATER CLOSET
10
11
F.D.
F.D.2'
- 10
"
3' -
4" M
AX T
O R
EFL
EC
TIVE
SU
RFA
CE
1
36
5
7
TOP
OF
CT
3' -
0"
3' - 6"
12" CT-1 FLOOR TILE
CT-2 WALL TILE
1' - 4"
P-4 WALL HUNG LAVPIPE INSULATION
2
W.C.
MR GWB
2
4
1
TOP
OF
CT
3' -
0" 6" CT AND BASE
8' -
0"
12" CT-1 FLOOR-TILE
MR GWB
OBSCURED GLASS, FIXED VINYL WINDOW 1x4 WOOD CASING
UU
3
1
OBSCURED GLASS, FIXED VINYL WINDOW
1x4 WOOD CASING
MR GWB
CT-2 WALL TILE
12" CT-1 FLOOR TILE
WATER CLOSET
UU
24
3' -
4" M
AX T
O R
EFLE
CIV
E S
UR
FAC
E
2' -
10"
3' - 6"
3' -
0"
PIPE INSULATION
MR GWB
5
6
P-4 WALL HUNG LAV.2
3
1 W.C.
CT-2 WALL TILE
12" CT-1 FLOOR TILE
CAULK
PAINTED MR GWB
ESCUTCHEON
1 1/2" DIA. GRAB BAR
3 4 &
CT-2
36" A.F.F.
GRAB BAR
34" A.F.F.
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
COMMONW
EALTH OF
V I RGIN
IACOLIN M. ARNOLD
No. 11337
ARCHI TECT
www.chpdesignstudio.orgPH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
A801
ENLARGEDTOILET PLANS& INTERIORELEVATIONS,TOILETACCESSORYSCHEDULE
THE STUDIO
THE STUDIO
DCC, CMA
CMA
09/16/2016
1603
KIN
GSR
IDGE APA
RTMEN
TS CLU
BHOUSE
BUILDIN
GRICH
MOND, V
IRGIN
IA
09/16/2016
1/2" = 1'-0"A8011 ENLARGED TOILET PLANS
1/2" = 1'-0"A801A H/C BATHROOM A
1/2" = 1'-0"A801B H/C BATHROOM B
TOILET ACCESSORY SCHEDULE
ITEM DESCRIPTION MOUNTING HEIGHTScheduleIdentity REMARKS
1 T.P. DISPENSER SEE SHEET HC101 TA2 18" GRAB BAR SEE SHEET HC101 TA3 36" GRAB BAR SEE SHEET HC101 TA VERTICAL4 42" GRAB BAR SEE SHEET HC101 TA5 24" X 36" TILT
MIRRORSEE SHEET HC101
6 SOAP DISPENSER SEE SHEET HC101 SURFACE MOUNTED7 PAPER TOWEL
DISPENSERSEE SHEET HC101 CCTA SURFACE MOUNTED
H/C DWH/C REF
1/2" = 1'-0"A801D H/C BATHROOM D
1/2" = 1'-0"A801C H/C BATHROOM C
3" = 1'-0"A8012 GRAB BAR/CT DETAIL
NOTE: SEE SHEET HC101 FOR GRAB BAR AND TOILET ACCESSORY MOUNTING HEIGHTS
WATER CLOSET
FIXTURE HW DISCHARGE TEMPERATURESMAXIMUM DISCHARGE
TEMPERATUREPLUMBING FIXTURE REFERENCE STANDARD
>85°F & <110°FPUBLIC HAND-WASHING FACILITIES ASSE 1070
WATER HEATER DETAIL - (WH-1)
TRAP PRIMER DETAIL
WATER HEATER
DRAIN PAN
EXPANSION TANK
DRAIN VALVE
VACUUM RELIEF VALVE
UNION
TEMPERATUREPRESSURE RELIEF VALVE
BALL VALVE
4" THICK CONCRETE PAD,6" WIDER THANEQUIPMENT
FOR CONTINUATIONREFER TO SHEET P101
SERVICE VALVE
TRAP PRIMING VALVE
UNION
9-1/2"
1/2" PIPE TO DRAIN
NOTE: DESIGN BASED ON PPP MODEL #
ELECTRIC WATER HEATER SCHEDULE
REMARKSMOUNTINGELECTRICAL
PHASEVOLTSKILOWATTS
STORAGECAPACITY
LOCATIONTYPEMARK
INSTALL PER MANUFACTURER'S RECOMMENDATIONPAN1240 V4.5 KW50 GALMAINTENANCE SHOPTANKWH-1
TOTALACCEPTANCE
1.19 GAL0.50 GAL
EXPANSION TANK
NOTE: PROVIDE LISTED TEMPERING DEVICE FOR EACH FIXTURE PER TABLE.
NOT TO SCALE
NO SCALE
VENT THROUGH ROOF (VTR)
SANITARY WASTE PIPE (WP)
SANITARY VENT PIPE (VP)
FLOOR DRAIN (FD)
PIPE TURN UP
PIPE TURN DOWN (DN)
CHECK VALVE (CV)
WALL HYDRANT (WH)
BALL VALVE (BV)
WALL CLEAN OUT (WCO)
SHEET WHERE SHOWN/CUT
DETAIL/RISER/ENLARGED PLAN
NEW WORK NOTE DESIGNATION
REDUCED PRESSURE
FLOOR CLEAN OUT (FCO)
DOMESTIC COLD WATER (DCW)
DOMESTIC HOT WATER (DHW)
BACKFLOW PREVENTER (RPBP)
POUNDS PER SQUARE INCH
PLUMBING FIXTURE MARK
PHASE/DIAMETER
AUTOMATIC TRAP PRIMER
KILOWATTS
PSI
P-#
Ø
TYP TYPICAL
W/ WITH
TPBFF BELOW FINISH FLOOR
ELEV ELEVATION
FINISH GRADEFG
GAL GALLON
GPM GALLONS PER MINUTE
INVERTINV
ABOVE FINISHED GRADEAFG
ADA
AC ABOVE CEILING
KW
AMERICANS WITH
DISABILITIES ACT COMPLIANT
WATER HEATER MARKWH-#
DFU DRAINAGE FIXTURE UNIT
SUPPLY FIXTURE UNITSFU
Ø
DW DISHWASHER
ALL PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFFSET A MINIMUM OF 3'-0" AT ROOF BEFORE ROOF PENETRATION.
ALL PLUMBING VENTS WITHIN A 10'-0" RADIUS OF ANY ROOF TOP UNIT SHALL BE EXTENDED TO A HEIGHT OF 3'-0" ABOVE THE FRESH AIR INTAKE.
ALL PLUMBING & PLUMBING MATERIALS SHALL MEET THE REQUIREMENTS OF THE STATE & LOCAL PLUMBING CODES.
ALL WALL HYDRANTS SHALL BE MOUNTED 24" ABOVE FINISHED GRADE UNLESS OTHERWISE SPECIFIED.
SLOPES & INVERT ELEVATIONS OF ALL INTERIOR PIPING SHALL BE ESTABLISHED BEFORE ANY PIPING IS INSTALLED, IN ORDER THAT PROPER SLOPES WILL BE MAINTAINED. ALL PIPING SHALL BE RUN TO AVOID CONFLICTS WITH OTHER TRADES.
COORDINATE WITH ARCHITECTURAL WORKING DRAWINGS BEFORE ROUGHING-IN PLUMBING FIXTURES.
MAKE PROPER HOT & COLD WATER, WASTE, & VENT, ETC., PIPING CONNECTIONS TO ALL FIXTURES & EQUIPMENT EVEN THOUGH ALL BRANCHES, FITTINGS & CONNECTIONS ARE NOT SHOWN.
COORDINATE LOCATION OF ALL EQUIPMENT, FIXTURES & PIPING WITH STRUCTURAL & ALL OTHER TRADES. PIPING RUN AC SHALL BE RUN AS HIGH AS POSSIBLE.
ALL OPENINGS IN CEILINGS & PLENUM WALLS FOR PLUMBING PIPES SHALL BE SEALED AIR TIGHT.
SEE SITE PLAN FOR EXTENT OF ALL PIPING LEAVING & ENTERING BUILDING.
ALL HOT & COLD WATER PIPING INDICATED TO RUN ABOVE FINISHED CEILINGS OR IN EXTERIOR WALLS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE BUILDING INSULATION.
SLOPES & INVERT ELEVATIONS OF EXTERIOR SEWERS, MANHOLES, ETC., SHALL BE ESTABLISHED & VERIFIED BY PLUMBING CONTRACTOR BEFORE ANY PIPING IS INSTALLED IN ORDER THAT PROPER SLOPES WILL BE MAINTAINED & NECESSARY INVERT ELEVATIONS OBTAINED.
PROVIDE AUTOMATIC TRAP PRIMERS FOR ALL FLOOR DRAINS.
IT IS THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK & MATERIAL FOR A COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM HARDWARE &/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED & INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY FAMILIARIZE HIMSELF/HERSELF WITH THE EXISTING CONDITIONS. NOT ALL EQUIPMENT AND APPURTENANCES ARE SHOWN. FAILURE TO FOLLOW THIS STEP SHALL NOT BE A BASIS FOR CHANGE ORDERS.
INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS & ALL APPLICABLE LISTING REQUIREMENTS.
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JEFFREY H. SUMMERS
Lic. No. 041703
02−01−17
#16244
P001
LEGEND, NOTES
AND
ABBREVIATIONS
BKR
DLR
MAJ
JS
09/16/2016
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
LEGENDS & ABBREVIATIONSGENERAL NOTES
1 3/15/17 VHDA Comments
METAL ICE MAKER WALL BOX
L
W
D
ADA - KITCHEN SINK COUNTER TOP
WASHER WALL BOX
ADA - WALL MOUNTED LAVATORY ADA - DUAL BASIN WATER COOLER
P-3
MOUNTINGPIPE SIZES
HW CW WP VPTRAPMARK DESCRIPTION
ADA - KITCHEN SINK (2COMPARTMENT) 22x33x6-1/2"
1-1/2"2"1/2"1/2"'P'-TRAP
DETAIL BASED ON DAYTON GE 233214
SPECIFICATIONS:
1. SEAMLESS DIE DRAWN 22 GAUGE STAINLESS STEEL ADA COMPLIANT
SINK WITH EXPOSED SURFACE POLISHED TO A NON-POROUS FINISH.
FULLY COATED UNDERSIDE INSULATED FOR SOUND AND CONDENSATE.
2. 8" CENTER, TWO HANDLE BELOW DECKMOUNT FAUCET, POLISHED
CHROME PLATED FINISH TRIM, CAST BRASS BODIES, BRASS SPOUT AND
TRIM, WALL FORM SWING SPOUT, STANDARD 2.2 GPM FLOW CONTROL
AERATOR, 4" BLADE HANDLES, COLOR INDEX METAL HANDLES WITH
VANDAL RESISTANT SCREWS AND WITH HOSE SPRAY, AS
MANUFACTURED BY MOEN 7460.
3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME
FINISH RIGID SUPPLY RISERS. OFFSET GRID STRAINER AND ADJUSTABLE
'P'-TRAP WITH ANSI AND ADA APPROVED, VINYL MOLDED INSULATION
WITH NYLON FASTENER KITS, PAINTED AS DIRECTED BY THE ARCHITECT.
MOUNTING
WALL
PIPE SIZES
HW
3/4"
CW
3/4"
WP
2"
VP
1-1/2"
TRAP
'P'-TRAP
MARK DESCRIPTION
WASHER WALL BOX
DETAIL BASED ON GUY GRAY, MODEL "WB200HA"
SPECIFICATIONS:
1. GALVANIZED STEEL RECESSED WALL BOX WITH PRIMER COAT AND
HAMMER ARRESTERS. (2) 3/4" HOSE BIBBS & 2" STANDPIPE
CONNECTION.
MOUNTINGPIPE SIZES
HW CW WP VPTRAPMARK DESCRIPTION
ADA - WALL MOUNTEDLAVATORY
WALLMOUNTED
1-1/2"2"1/2"1/2"'P'-TRAP
SPECIFICATIONS:
1. VITREOUS CHINA ADA COMPLIANT WALL MOUNTED LAVATORY WITH
FRONT OVERFLOW & FAUCET HOLES ON 4" CENTERS & SELF DRAINING
DECK.
2. FAUCET DESIGN BASED ON MOEN 4621 LAVATORY FAUCET. CHROME
PLATED SOLID BRASS, POLISH CHROME PLATED FINISH, 0.5 GPM VANDAL
RESISTANT AERATOR, MIXING VALVE SET AT 110°F MAX (ASSE 1070).
3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME
FINISH RIGID SUPPLY RISERS. OFFSET GRID STRAINER AND ADJUSTABLE
'P'-TRAP WITH ANSI AND ADA APPROVED, VINYL MOLDED INSULATION
WITH NYLON FASTENER KITS, PAINTED AS DIRECTED BY THE ARCHITECT.
4. CONCEALED FLOOR MOUNT SUPPORT. WALL BRACKETS SHALL NOT BE
USED.
DETAIL BASED ON AMERICAN STANDARD, LUCERNE 0355-012
34"
FLOOR
MOUNTINGPIPE SIZES
HW
-
CW WP VPTRAPMARK DESCRIPTION
WALLMOUNTED
1/2" 1-1/2" 1-1/2"'P'-TRAPADA - DUAL BASIN
ELECTRIC WATER COOLER
SPECIFICATIONS:
1. DUAL BASIN UNIT SHALL DELIVER 8.0 GPH OF 50°F WATER @ 90°F
AMBIENT TEMPERATURE. TO INCLUDE FRONT AND SIDE PUSH
PADS. UNIT SHALL BE POWDER COATED GALVANIZED STEEL.
2. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH
CHROME FINISH RIGID SUPPLY RISERS. GRID STRAINER &
ADJUSTABLE 'P'-TRAP.
3. MOUNT PER MANUFACTURERS INSTRUCTIONS FOR ADA
COMPLIANCE.
DETAIL BASED ON OASIS PGF8EBF
36"
38"-43"
FLOOR
P-2P-1 P-4
P-5 P-7
COUNTERTOP
DETAIL BASED ON IPS CORPORATION, "WATER-TITE"
SPECIFICATIONS:
1. SPACE SAVER RECESSED VALVE BOX WITH 1/2" ANGLE STOP WITH 1/4"
COMPRESSION CONNECTION AND INTEGRAL WATER HAMMER
ARRESTOR.
2. HIGH IMPACT POLYSTYRENE BOX.
3. BOTTOM OF BOX 6"-12" AFF BUT ABOVE BASEBOARD.
ICE MAKER WALL BOX WALL
UTILITY SINK
ADA - WATER CLOSET
MOUNTING
FLOOR
PIPE SIZES
HW
1/2"
CW
1/2"
WP
2"
VP
1-1/2"
TRAP
'P'-TRAP
MARK DESCRIPTION
UTILITY SINK
SPECIFICATIONS:
1. SOLID, CONTINUOUS MOLDED STONE SINK WITH 4" FAUCET LEDGE.
2. WHITE BAKED ENAMEL LEGS WITH LEVELING FEET.
3. 2 HANDLED SOLID BRASS FAUCET WITH CHROME FINISH, SPOUT
WITHOUT HOSE THREADS.
4. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME
FINISH RIGID SUPPLY RISERS. GRID STRAINER & ADJUSTABLE 'P'-TRAP.
DETAIL BASED ON FIAT, "SERV-A-SINK"
MOUNTINGPIPE SIZES
HW
-
CW WP VPTRAPMARK DESCRIPTION
ADA - DUAL FLUSHVALVE WATER CLOSET
INTEGRAL 1/2" 4" 2" FLOOR
SPECIFICATIONS :
1. VITREOUS CHINA ADA COMPLIANT FLOOR MOUNTED FLUSH TANK
WATER CLOSET WITH FULLY GLAZED 2" TRAPWAY, ELONGATED
SIPHON JET BOWL, 1.1/1.6 GALLONS PER FLUSH. FLUSH HANDLE
LOCATED ON WIDE SIDE OF STALL.
2. WHITE SOLID PLASTIC OPEN FRONT ELONGATED SEAT WITH
EXTERNAL CHECK HINGES, INTEGRAL BUMPERS, LESS COVER.
DETAIL BASED ON TOTO ECO DRAKE CST 744EL
P-6
MARK DESCRIPTION MOUNTINGPIPE SIZES
HW
-
CW
1/2"
WP
-
VP
-
TRAP
-
plate 1100
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JEFFREY H. SUMMERS
Lic. No. 041703
02−01−17
#16244
P002
FIXTURE PLATES
BKR
DLR
MAJ
JS
09/16/2016
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
1 3/15/17 VHDA Comments
2
16
13
12
11
10
3
8
7 6
5
9
14
1
WH-1P-5(TYP. OF 3)
P-1
P-1P-2
P-2
P-4
P-3
P-6
1-1/2" RPBP
1-1/2" CW SERVICE
WH
WH
FCO
FCO
2" FD W/ TP
2" FD W/ TP
3" FD W/ TP
4" WP INV. ELEV.=3.00' BFF (27.5 DFU)
P-7
AC
AC
BF
4" WCO
BFF
TP
TP
S1P601
W1P601
TP
DW
2" FD W/ TP
15
1
FOR CONTINUATION REFER TO CIVIL UTILITY PLAN.
FOR CONTINUATION REFER TO CIVIL UTILITY PLAN.
WCO
AP
1 REFER TO DETAILS ON P601 FOR RPBP.
1/4" = 1'-0"5' 10'0' 5'
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JEFFREY H. SUMMERS
Lic. No. 041703
02−01−17
#16244
GRAPHIC SCALE:
P101
FIRST FLOOR
PLAN
BKR
DLR
MAJ
JS
09/16/2016
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
SCALE: 1/4" = 1'-0"
FIRST FLOOR PLAN
1ST FLOOR ROOM
SCHEDULE
1 COMMUNITY ROOM
2 KITCHENETTE
3 RECEPTION
5 CONF ROOM
6 FILES
7 MECH/ELC
8 STORAGE
9 CORRIDOR
10 MECH/JANITOR CLOSET
11 H/C WOMEN'S TOILET
12 H/C MEN'S TOILET
13 LAUNDRY
14 FITNESS
15 MAINT SHOP
16 VESTIBULE
NOTES THIS SHEET
1 3/15/17 VHDA Comments
REDUCED PRESSURE BACKFLOW PREVENTER INSTALLATION DETAILNO SCALE
AIR GAP FITTINGFLANGE BOLTEDGALVANIZED PIPE
SHUT OFF VALVE (TYP.)
BRONZE TEST COCK (TYP.)
BRONZE PIPE SADDLESUPPORT
FROM CITY WATERSUPPLY
1-1/2" REDUCED PRESSUREPRINCIPLE BACKFLOWPREVENTER
SUPPORTGALVANIZED PIPE
TO FLOOR
TO BUILDINGDOMESTICWATER SUPPLY
BACKFLOW PREVENTER ASSEMBLY AND THE CITY WATER METER.NO DEVICES, VALVES, BRANCH LINES, ETC. SHALL BE INSTALLED BETWEENNOTE:
12" M
IN.
SFU NOTE:
DFU NOTE:
BACKFLOW PREVENTER DISCHARGE PIPING DETAILNO SCALE
18" MINIMUM OR *
X AND Y BY 1 SIZE.
X" x Y" SCHEDULE 40 PVC ELBOW
* = INCREASE BOTH PIPE SIZESCONCRETE FLOOR SLAB
AT MINIMUM 1/4" PER FOOT SLOPEDISCHARGE PIPE Y" SCH 40 PVC
10'-0" MAXIMUM OR *
AIR GAP: 4" MINIMUM
X" SCHEDULE 40 PVC RISER PIPE(SECURE TO WALL OR FLOOR)
RISERPIPE "X"SIZE,INCHES
FITTING TO ADAPT AIR TO PIPE DIAMETER REQUIRED
AIR GAP FITTING ON RPBP
BLD
G. E
XTE
RIO
R
PREVENTER
INCHES
BACKFLOW
3/4"1"
SIZE,
3"2"1 1/2"
4"6"
8"10"
8"
RATE,GPM
3050
160320
100
DESIGNDISCHARGE
SIZE,
RISER
2"3"
INCHES
PIPE "Y"
4"6"
4"
BLDG. INTERIOR
PROVIDE DOWNSPOUT NOZZLE
(LAMBS TONGUE) ON EXTERIOR
WALL FOR DISCHARGE PIPING
SUPPORT AS REQUIRED
NOTES THIS SHEET:
PLUMBING WATER RISER DIAGRAM
PLUMBING WASTE RISER DIAGRAM S1
W1
RPBP
1-1/2" CW SERVICE
1-1/4"
WH-1 P-7 P-5
'A'
P-5
'A'
P-5
'A'
P-2
1/2"
P-1P-2
1/2"
P-1P-4
1/2"
P-6
1/2"
P-3
1/2"
WH WH
PROVIDE THERMOSTATIC MIXING VALVE SET AT 110°F MAX(ASSE 1070). THIS RISER ADDS 55.5 SFU's TO
THE DOMESTIC WATER SYSTEM.
THIS PROJECT ADDS 27.5 DFU'sTO THE SANITARY WASTESYSTEM.
FCO
FCOWCO
2" FDW/ TP
2" FDW/ TP
2" FDW/ TP
3" FDW/ TP
3" VTR
2"
4"
P-3
P-4
P-2
P-2
P-1
P-1
P-5
P-5
P-5
4"
4"
4"
4" 3"
4"
4"
4"
2"
2"
2"
3"
2"
3"
3"
3"
3"
2"
2"
1-1/2"
1-1/2"
2"
1-1/2"
2"
4"
3"
3"
1-1/2"
2"
"A" WHA (TYP.)"A" WHA 1-1/2"1-1/2"1-1/2"1-1/4"1/2"3/4"
1-1/4" 1-1/4" 1"1"1/2"
1-1/2" 1-1/4" 1-1/4" 3/4"
1" 1" 1" 3/4"
3/4" 3/4" 3/4" 3/4"
4" WPINN. ELEV. = 3.00' BFF (27.5 DFU)
DW
1/2" 1/2"
1-1/2"
WYE STRAINER
MAINISOLATIONVALVE
WCO
P-7
2"
ET
3/4"
NO SCALE
1
11
NO SCALE P101
P101
15 1312112 97
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JEFFREY H. SUMMERS
Lic. No. 041703
02−01−17
#16244
P601
RISER DIAGRAM
BKR
DLR
MAJ
JS
09/16/2016
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
1 3/15/17 VHDA Comments
GENERAL ITEMS
GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH HVAC DRAWING OF THIS SET. SEE EACH DRAWING FOR SPECIFIC NOTES APPLICABLE TO THAT DRAWING.
COORDINATE THAT OUTSIDE AIR INTAKE OPENINGS FOR VENTILATION AIR ARE LOCATED AT LEAST 10 FEET MEASURED IN ANY DIRECTION FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE SUCH AS FLUES, VENTS, CHIMNEYS, GAS METERS, GAS REGULATORS, PLUMBING VENTS, ETC., UNLESS TOP OF SUCH INTAKE OPENING IS 3 FEET OR GREATER BELOW ANY OF THE LISTED ITEMS.
OVERHEAD PIPING IN SPACES WITHOUT HUNG CEILINGS SHALL BE RUN AS CLOSE TO ROOF DECK AS PRACTICAL, AS CLOSE TO PARALLEL JOISTS AS POSSIBLE AND ABOVE LIGHTING FIXTURES TO CONCEAL PIPING.
OVERHEAD DUCTWORK AND PIPING IN SPACES WITH CEILINGS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.
PROVIDE PIPE SLEEVES LARGE ENOUGH TO ALLOW FOR REQUIRED LATERAL MOVEMENT OF PIPING.
COORDINATE LOCATION OF GRILLES, REGISTERS, DIFFUSERS, THERMOSTATS AND OTHER WALL OR CEILING MOUNTED HVAC ACCESSORIES WITH REFLECTED CEILING PLAN, LIGHTING FIXTURE LAYOUT AND ACCESSORIES INSTALLED BY OTHER TRADES SO AS TO PRESENT A NEAT AND ATTRACTIVE INSTALLATION THROUGHOUT THE ENTIRE BUILDING. IT IS THE INTENT FOR GRILLES, REGISTERS AND DIFFUSERS TO BE INSTALLED IN THE CENTER OF CEILING PANELS.
ARRANGE PIPING AND DUCTWORK, PARTICULARLY ABOVE CEILING AS REQUIRED TO CLEAR STRUCTURE, DUCTS, CONDUITS, ETC. ALLOWING SPACE FOR PIPE HANGERS, EXPANSION LOOPS AND ACCESS TO VALVES, FILTERS, AND MAINTENANCE OF EQUIPMENT.
CONTRACTOR SHALL VERIFY REFRIGERANT PIPE SIZES WITH EQUIPMENT MANUFACTURER FOR THE INDICATED INSTALLATION.
COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER TRADES.
DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DOORS, WINDOWS, ETC.
THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE LOCATED IN THE ROOMS INDICATED. INSTALL AT APPROX. 46" ABOVE FINISH FLOOR TO MATCH THE HEIGHT OF WALL SWITCHES OR OTHER WALL MOUNTED DEVICES.
PIPING, DUCTWORK, VENTS, ETC., EXTENDING THROUGH EXTERIOR WALLS AND ROOF SHALL BE FLASHED AND COUNTER FLASHED IN A WEATHERPROOF MANNER.
EXTEND DRAIN LINES AS INDICATED. ROUTING SHALL NOT INTERFERE WITH PASSAGEWAYS AND MAINTENANCE. DRAINS FROM AIR CONDITIONING CONDENSATE DRAIN PANS SHALL BE TRAPPED. SLOPE CONDENSATE DRAIN PIPING AT 1/4" PER FOOT. VERIFY INVERT IS ESTABLISHED AFTER AIR HANDLING UNIT IS INSTALLED BUT PRIOR TO DUCTWORK INSTALLATION.
EQUIPMENT CONTAINING AIR CONDITIONING COILS WHICH DO NOT HAVE A SECONDARY DRAIN OR AUXILIARY DRAIN PAN SHALL BE FITTED WITH A WATER LEVEL SENSOR IN THE PRIMARY DRAIN PAN. THE SENSOR SHALL BE WIRED TO DE-ENERGIZE THE EQUIPMENT IF WATER RISES ABOVE THE DRAIN OUTLET.
PIPING AND DUCTWORK INSULATION SHALL BE RUN CONTINUOUSLY THROUGH NON-RATED FLOORS, WALLS, ROOF AND PARTITIONS, UNLESS OTHERWISE INDICATED.
NO PIPING SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED.
RUNOUTS SHALL PITCH DOWN IN DIRECTION OF FLOW A MINIMUM OF 1" IN 3'.
PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATIONS. ADDITIONAL SUPPORTS OR HANGERS SHALL BE ADJACENT TO ELBOWS, TO PREVENT WEIGHT OF PIPING BEING PLACED ON THE EQUIPMENT.
LOCATE AND SIZE CONCRETE PADS AND CURBS FOR MECHANICAL EQUIPMENT IN ACCORDANCE WITH ACTUAL EQUIPMENT PURCHASED.
FOR LOCATION OF MOTOR STARTERS, SEE ELECTRICAL DRAWINGS.
THROUGH-PENETRATION FIRESTOP ASSEMBLIES
PROVIDE UL LISTED THROUGH-PENETRATION ASSEMBLIES FOR FIREWALLS AND FLOORS. REVIEW ARCHITECTURAL DRAWINGS FOR FIRE PARTITION LOCATIONS AND UL LISTINGS.
SHEET METAL
FLOOR SIDEWALL REGISTERS OR GRILLES SHALL BE LOCATED 12" FROM BOTTOM OF REGISTER OR GRILLE TO FINISHED FLOOR.
INSTALL FLOOR REGISTERS AND CEILING REGISTERS A MINIMUM OF 4" FROM EXTERIOR WALL.
PROVIDE A MINIMUM OF THREE TIMES THE FAN DIAMETER OF STRAIGHT DUCTWORK OFF THE SUPPLY AIR FAN DISCHARGE BEFORE ANY TAKEOFFS OR ELBOWS.
PROVIDE EXTENDED VOLUME DAMPER CONTROL RODS SO THAT HANDLES ARE WELL CLEAR OF DUCT INSULATION.
MAINTENANCE
EQUIPMENT WITH FILTERS SHALL BE INSTALLED SO THAT FILTERS CAN BE EASILY REMOVED AND REPLACED.
EQUIPMENT INSTALLED ABOVE CEILINGS SHALL BE MOUNTED APPROX. 12" ABOVE CEILING (UON) FOR MAINTENANCE ACCESS.
INSTALL PIPE RUNS AT LEAST 6" ABOVE CEILING TILES. WHERE PRACTICAL INSTALL VALVES, AND OTHER MAINTAINABLE DEVICES LOW ENOUGH TO REACH WITH A 6' LADDER.
PROVIDE ACCESS TO ANY INSPECTION OR MAINTAINABLE DEVICE, EQUIPMENT, ETC. -ACCESS OR ACCESS DOOR SHALL BE OF ADEQUATE SIZE TO WORK ON DEVICE.
EXAMINE MANUFACTURER'S LITERATURE TO DETERMINE RECOMMENDED CLEARANCES. THESE CLEARANCES SHALL BE ESTABLISHED AND MAINTAINED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THESE REQUIREMENTS WITH ALL OTHER TRADES.
NEW WORK NOTE DESIGNATION
CONDENSATE DRAIN PIPINGD
EXTERNAL STATIC PRESSURE
EXHAUST AIR
PHASE/DIAMETER
ESP
CUBIC FEET PER MINUTE
Ø
APPROX. APPROXIMATELY
E.A.
AHU-1 AIR HANDLING UNIT DESIGNATION
EF-1 EXHAUST FAN DESIGNATION
HP-1 HEAT PUMP DESIGNATION
LV-1 LOUVER DESIGNATION
CFM
INCHIN
MAXIMUMMAX
1000 BRITISH THERMAL UNITS PER HOURMBH
MINIMUM CIRCUIT AMPSMCA
MINIMUMMIN
MAXIMUM OVERCURRENT PROTECTIONMOCP
NOISE CRITERIANC
OUTSIDE AIRO.A.
PRESSURE DROPP.D.
RETURN AIRR.A.
SUPPLY AIRS.A.
SEASONAL ENERGY EFFICIENCY RATINGSEER
SENSIBLESENS.
TYPICAL(TYP.)
UNLESS OTHERWISE NOTEDU.O.N.
WATER GAUGEWG
RETURN AIRR.A.
PIPE TURNING UP
PIPE TURNING DOWN
REFRIGERANT LIQUID PIPINGRL
REFRIGERANT SUCTION PIPINGRS
WALL THERMOSTAT
VOLUME DAMPER
X
XXX
GRILLE, REGISTER, OR DIFFUSER MARK
(CFM AS INDICATED)
SUPPLY AIR/OUTSIDE AIR DUCT SECTION
RETURN AIR DUCT SECTION THROUGH ROOF
CEILING DIFFUSER WITH FLEXIBLE DUCTWORK
RETURN REGISTER WITH DUCTWORK
EXHAUST GRILLE WITH DUCTWORK
MITERED ELBOW WITH TURNING VANES
T
DIAMETERDIA.
KILOWATTKW
HEATING SEASONAL PREFORMANCE FACTORHSPF
NUMBERNO.
SQUARE FOOTSF
RV-1 ROOF VENT DESIGNATION
FIRE STOPPING NOTE:PROVIDE AN APPROPRIATELY LISTED THROUGH-PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). FIRE STOPPING OF DUCT PENETRATIONS THROUGH RATED ASSEMBLIES ARE ONLY PERMITTED WHEN FIRE AND/OR SMOKE DAMPERS ARE NOT REQUIRED. SLEEVES SHALL ONLY BE PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH-PENETRATION FIRE STOPPING ASSEMBLIES AND ASSOCIATED UL DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED CONSTRUCTION ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSEM EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING SYSTEM IS NOT AVAILABLE, THE CONTRACTOR SHALL BRING THE CONDITION TO THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK.
ENERGY CODE COMPLIANCE PATH:ASHRAE 90.1
VECC CHAPTER 4 - PRESCRIPTIVE
VECC CHAPTER 4 - PERFORMANCE
AIR-TO-AIR SPLIT SYSTEM HEAT PUMP: THE SYSTEM SHAL BE CONTROLLED BY A 7-DAY PROGRAMMABLE COMBINATION THERMOSTAT/HUMIDISTAT WITH DEHUMIDIFICATION CYCLE, NIGHT SETBACK, AND OPTIMUM START CAPABILITIES. CONTROLS SHALL BE IN COMPLIANCE WITH THE 2012 VIRGINIA ENERGY CONSERVATION CODE.
ECONOMIZER MODE (AHU-3 ONLY): A COMPARATIVE ENTHALPY ECONOMIZER STRATEGY SHALL BE UTILIZED. THE OUTSIDE AIR DAMPER SHALL MODULATE OPEN AND THE RETURN AIR DAMPER SHALL MODULATE CLOSED WHEN OA ENTHALPY IS LESS THAN RETURN AIR ENTHALPY IN COOLING MODE. COMPRESSOR SHALL BE DE-ACTIVATED IF SA TEMPERATURE FALLS BELOW 55°F AND ECONOMIZER DAMPERS SHALL MODULATE TO MAINTAIN 54°F UNTIL THERE IS A CALL FOR HEAT.
EXHAUST FANS:
EF-1: FAN SHALL BE CONTROLLED BY A COMMON FAN/LIGHT SWITCH UNLESS OTHERWISE NOTED ON PLAN.
EF-2: FAN SHALL BE CONNECTED TO AHU-3 ECONOMIZER MODE. WHEN AHU-3 IS IN ECONOMIZER MODE, FAN SHALL BE ENERGIZED. WHEN AHU-3 IS NOT IN ECONOMIZER MODE, FAN SHALL BE DE-ENERGIZED.
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
ERIC T. SNYDER
Lic. No. 055687
02−01−17
#16244
M001
LEGEND,
NOTES AND
ABBREVIATIONS
JBH
JBH
GG
ETS
03/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
GENERAL NOTES LEGENDS & ABBREVIATIONS
4. PROVIDE WITH BIRDSCREEN AND BACKDRAFT DAMPER.
3. PROVIDE COLOR CHART FOR FINISH SELECTION BY ARCHITECT.
2. PROVIDE ALUMINUM STORMPROOF CONSTRUCTION.
1. LOUVER SHALL BE SEIHO MODEL RCC-S.
NOTES:
LV-1 DRYER VENT 4" 0.04 - SEE NOTES
TAG SERVICE SIZE (IN.) WxH (SF) C.F.M. REMARKS
FREE AREA
LOUVER SCHEDULE
SEQUENCE OF OPERATIONS
5. DIFFUSERS LOCATED IN HARD CEILING SHALL BE PROVIDED WITH REMOVABLE FACE TO PROVIDE ACCESS TO VOLUME DAMPERS.
4. PROVIDE 4-WAY PATTERN CEILING DIFFUSERS U.O.N. ON PLANS.
3. MAXIMUM PRESSURE DROP SHALL INCLUDE VOLUME DAMPER WHERE DAMPER IS PROVIDED.
AND BAKED ENAMAL FINISH (INCLUDING HEAD OF SCREWS), PROVIDE REGISTERS WITH RADIATION DAMPERS, DOUBLE DEFLECTION, AND 3/4" BLADE SPACING.
2. PROVIDE SURFACE MOUNTED ALUMINUM DIFFUSERS WITH OPPOSED BLADE VOLUME DAMPERS WITH INTERNAL SCREW ADJUSTMENT,
1. SELECTIONS BASED ON TITUS OR APPROVED EQUAL. NC SHALL NOT EXCEED 25.
THE FOLLOWING NOTES ARE TYPICAL UNLESS OTHERWISE NOTED:
Z REGISTER RETURN 800-1500 30x12 0.1 350F 35 DEG DEFLECTION, 1/2" BLADE SPACING
Y REGISTER RETURN 0-750 14x14 0.1 350F 35 DEG DEFLECTION, 1/2" BLADE SPACING
H DIFFUSER SUPPLY 105-215 8 0.1 TDCA SURFACE MOUNT, 4-WAY BLOW PATTERN
G DIFFUSER SUPPLY 0-100 6 0.1 TDCA SURFACE MOUNT, 4-WAY BLOW PATTERN
F DIFFUSER SUPPLY 105-205 8 0.1 TDCA 24x24 LAY-IN PANEL, 4-WAY BLOW PATTERN
E DIFFUSER SUPPLY 0-100 6 0.1 TDCA 24x24 LAY-IN PANEL, 4-WAY BLOW PATTERN
C REGISTER SUPPLY 105-200 10x6 0.1 300F SURFACE MOUNT, 3/4" BLADE SPACING
B REGISTER SUPPLY 45-100 8x4 0.1 300F SURFACE MOUNT, 3/4" BLADE SPACING
A REGISTER SUPPLY 0-40 6x4 0.1 300F SURFACE MOUNT, 3/4" BLADE SPACING
TAG TYPE SERVICE RANGE SIZE P.D. MODEL NO. REMARKS
C.F.M. NECK MAX.
GRILLE, REGISTER & DIFFUSER SCHEDULE
5. PROVIDE AHU-3/HP-3 WITH THERMOSTAT CAPABLE ECONOMIZER AND HUMIDITY CONTROL.
AND 7-DAY PROGRAMMABLE COMBINATION THERMOSTAT/HUMIDISTAT. CONTROLS SHALL BE IN ACCORDANCE WITH THE 2012 VIRGINIA ENERGY CONSERVATION CODE AND INCLUDE SETBACK AND OPTIMUM START CAPABILITIES.
4. EXTERNAL STATIC PRESSURE INCLUDES SUPPLY, RETURN AND OUTSIDE AIR DISTRIBUTION SYSTEMS. PROVIDE R410A REFRIGERATION, DEHUMIDIFICATION SEQUENCE, 1" MERV 8 FILTER,
3. SUPPLEMENTAL ELECTRIC HEATER F.L.A. INCLUDED. PROVIDE ONE DISCONNECT SWITCH FOR EACH INDOOR UNIT.
2. EQUIPMENT SHALL BE BY RHEEM OR APPROVED EQUAL.
1. PERFORMANCE SHALL BE BASED ON DOE PROCEDURES AND ANSI/AHRI STANDARD 210/240.
NOTES:
AHU-3 / HP-3 1575 350 0.5 58.5 39.4 16.0 62.0 9.0 17.0 97.0 100 240 1 RH2T60 44.0 60 240 1 RP1760 SEE NOTES
AHU-2 / HP-2 750 140 0.5 24.0 17.3 16.0 25.8 9.0 7.2 41.0 45 240 1 RH2T24 21.0 35 240 1 RP1724 SEE NOTES
AHU-1 / HP-1 660 115 0.5 18.5 14.5 16.0 15.7 9.0 4.8 29.0 30 240 1 RH1T24 12.0 15 240 1 RP1518 SEE NOTES
TAG C.F.M. CFM IN. W.G. M.B.H. M.B.H. S.E.E.R. M.B.H. H.S.P.F. KW M.C.A. M.O.C.P. VOLTS PHASE NUMBER M.C.A. M.O.C.P. VOLTS PHASE NUMBER REMARKS
TOTAL O.A. E.S.P. TOTAL SENS. MIN. TOTAL MIN. SELECTED MODEL MODEL
INDOOR OUTDOOR
FAN DATA COOLING DATA HEATING DATA ELECTRICAL DATA ELECTRICAL DATA
AIR HANDLER UNIT OUTDOOR UNIT
SPLIT SYSTEM HEAT PUMP SCHEDULE - AIR TO AIR
4. SELECTION BASED ON COOK MODEL GC.
OFF-WHITE ALUMINUM INTAKE GRILLE.
3. PROVIDE CABINET CEILING FANS WITH CHATTERPROOF BDD, INTEGRAL ELECTRICAL DISCONNECT, DUCT FLANGE, AND INTEGRAL
2. PROVIDE DIRECT DRIVE FANS WITH ELECTRONIC SPEED CONTROLLER.
1. FAN SHALL BE BROAN MODEL LP80.
NOTES:
EF-2 ROOF CENTRIFUGAL 1225 0.35 - DIRECT - 1/2 120 1 2,3,4
EF-1 RESTROOM CABINET 50 0.35 3 DIRECT 60 - 120 1 1,2,3
TAG LOCATION FAN TYPE C.F.M. (IN. WG.) SONES DRIVE WATTS H.P. VOLTS PHASE REMARKS
E.S.P. MAX
FAN SCHEDULE
2. PROVIDE WITH MFGR'S ROOF CURB, BIRDSCREEN, AND BACKDRAFT DAMPER.
1. VENT SHALL BE LOW PROFILE AND APPROVED FOR SLOPED ROOF APPLICATIONS.
NOTES:
RV-3 EXHAUST 20" 1225 SEE NOTES
RV-2 EXHAUST/INTAKE 12" 250-500 SEE NOTES
RV-1 EXHAUST/INTAKE 8" 0-250 SEE NOTES
TAG SERVICE DIA. C.F.M. REMARKS
SIZE (IN.)
ROOF VENT SCHEDULE1 3/15/17 B.O. CCOMMENTS
T
T
T
2
16
13
12
11
10
3
8
76
5
9
14
1
4 HP-1
4 HP-3
4 HP-2
F
200E
75C
130
C
130
B
75
A
25
A
25
H
150
H
150
E
50
A
25
A
30
A
25
G
80
G
80
G
80
G
80
1 AHU-3
1 AHU-2
2 EF-1
2 EF-1
3
3
6
6
3
Y
485
Z 1225
Y 530
5
5
5
LV-1 7
12"x10"
8"x10"
12"x10"
10"x10"
8"ø
8"x8"
8"ø
6"x10"
12"x10"
10"x10"
10"x8"
8"x8"
6"x8"
H
200
H
200
H
200
H
200
H
200
H
200
H
175
1 AHU-1
4
15
8
8
8
(TYP.)
14"x12"
H
200
2 EF-1
16"x16"
8"ø
8"ø
8"ø
8"ø
8"ø
8"ø
8"ø
6"ø6"ø
6"ø
8"ø 6"ø
6"ø8"ø
6"ø
8"ø6"ø
6"ø
6"ø 6"ø
6"ø 6"ø
6"ø
6"ø
8"ø
6"ø
6"x6"
10x10 UP TO RV-1
SPLASH BLOCK (TYP.)
D
D
RV-1
RV-3
RV-1
CEILING SOFFIT LINE
RETURN HIGH
RETURN LOW
RETURN LOW
2 EF-2
C
C
C
CC
5 RV-2
12"x12"
1 PROVIDE SPLIT SYSTEM AIR HANDLING UNIT, SUPPORTS, AND EMERGENCY DRAIN PAN COMPLETE. MAINTAIN MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES. VERIFY WITH ACTUAL EQUIPMENT PURCHASED. PROVIDE HONEYWELL Y8150 (OR APPROVED EQUAL) FRESH AIR VENTILATION SYSTEM AND MANUAL VOLUME DAMPER ON OUTSIDE AIR DUCT RISER COMPLETE. REFER TO AIR HANDLING UNIT DETAIL ON SHEET M501.
PROVIDE EXHAUST FAN, DUCTWORK, HANGERS AND SUPPORTS COMPLETE. ROUTE DUCTWORK UP THROUGH ROOF VENT. REFER TO ARCHITECT PLANS FOR ROOF VENT LOCATION.
PROVIDE REFRIGERANT SUCTION/LIQUID PIPING, INSULATION, JACKETING, HANGERS AND SUPPORTS COMPLETE. ROUTE PIPING WITHIN WALL CAVITY TO ASSOCIATED AHU. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
PROVIDE HEAT PUMP COMPLETE. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND ENSURE ALL RECOMMENDED CLEARANCES ARE ACHIEVED. EACH UNIT SHALL BE LOCATED A MINIMUM OF 2'-0" FROM ANY OBSTRUCTIONS. MOUNT ON CONCRETE EQUIPMENT CURB.
PROVIDE ROOF VENT COMPLETE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE SCHEDULE ON SHEET M001.
PROVIDE CONDENSATE DRAIN PIPING AND INSULATION COMPLETE. ROUTE PIPING THROUGH EXTERIOR WALL AND TERMINATE AT SPLASH BLOCK.
PROVIDE 4" DRYER EXHAUST DUCT IN ACCORDANCE WITH THE 2012 INTERNATIONAL MECHANICAL CODE, SECTIONS 504.2, 504.4, AND 504.7.
PROVIDE 7-DAY PROGRAMMABLE COMBINATION THERMOSTAT/HUMIDISTAT AND CONTROL WIRING COMPLETE. MOUNT APPROXIMETELY CENTERLINE WITH ADJACENT SWITCHES. SEE DETAIL ON SHEET M501.
2
3
4
5
6
7
8
1/4" = 1'-0"5' 10'0' 5'
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
ERIC T. SNYDER
Lic. No. 055687
02−01−17
#16244
GRAPHIC SCALE:
M101
FIRST FLOOR
PLAN
JBH
JBH
GG
ETS
03/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
SCALE: 1/4" = 1'-0"
FIRST FLOOR PLAN
1ST FLOOR ROOM
SCHEDULE
1 COMMUNITY ROOM
2 KITCHENETTE
3 RECEPTION
4 WORK ROOM
5 CONF ROOM
6 FILES
7 MECH/ELC
8 STORAGE
9 CORRIDOR
10 MECH/JANITOR CLOSET
11 H/C WOMEN'S TOILET
12 H/C MEN'S TOILET
13 LAUNDRY
14 FITNESS
15 MAINT SHOP
16 VESTIBULE
NOTES THIS SHEET
1
1 3/15/17 B.O. CCOMMENTS
USE ONLY WHERE RECTANGULAR RUN-OUTS ARE INDICATED ON DRAWINGS
USE ONLY WHERE ROUND RUN-OUTS ARE INDICATED ON DRAWINGS
SINGLE PIPE RUN
NOTE:
FLEXIBLE DUCT INSTALLATION DETAIL INSULATED FLEXIBLE DUCTWORK DETAIL
PIPE SUPPORT DETAILS
ROUND DUCT SUPPORT DETAILS
EXHAUST/INTAKE ROOF CAP DETAIL
AIR HANDLING UNIT DETAIL
CONCRETE PAD DETAIL - EXTERIOR EQUIPMENT MOUNTING STAND DETAIL
SWITCH/THERMOSTAT MOUNTING HEIGHT DETAILNO SCALE
TYPICAL BRANCH CONNECTION
BELL MOUTH DUCT TAP -IN WITH VOLUME DAMPERAND INSULATION
FLEXIBLE DUCT
BEAD
DUCT STRAP CABLE TIE,PLENUM RATED AND LISTEDFOR USE PER UL-181
SHEET METAL DUCT WITHEXTERIOR INSULATION
NO SCALE
MAXIMUM SAG SHALL BE 1/2"PER FOOT OF SUPPORTSPACING.
STRAP BRACINGSHALL BEPROVIDED AT AMAXIMUM OF 3'-0"ON CENTER.
MAXIMUM FLEXIBLE DUCTLENGTH SHALL BE 5'-0".
NO SCALE
MAIN DUCT
45°
45°
W
SA/OA
RA/EA
L = 1/4WL (4" MIN.)
BRANCH DUCT
BALANCING DAMPER (B.D.)
W
SA/OA
RA/EAMAIN DUCT
BRANCH DUCT
BALANCING DAMPER (B.D.)
ROUND
RECTANGULAR
L (4" MIN.)
L = 1/4W
NO SCALE
CLEVIS HANGER (SIZEAS REQUIRED)
SUPPORT FROMROOF JOIST
INSULATION SADDLE
3/8" THREADEDROD
NO SCALE
SECURE WIRE
10"Ø MAX.
36"Ø MAX.
SUPPORTFROMSTRUCTUREABOVE (TYP)
BAND
HANGERS, RODS,WIRES, ORSTRAPS
24"Ø MAX
LOAD RATEDFASTENERS
HANGER
NO SCALE
BACKDRAFT DAMPER
EXHAUST DUCT, SEEDRAWINGS FOR SIZE
ROOF TRUSS
SPUNALUMINUM,RUSTPROOFVENT SELFFLASHING
NO SCALE
NO SCALE
6" ALL AROUND UNIT
45° CHAMFER
GRADE
4"2"
NO SCALE
6/6 10/10WIRE MESH
EQUIPMENT
DIMENSIONS TOSUIT EQUIPMENT
3" x 3" x 1/4" STEEL ANGLES,ALL-WELD CONSTRUCTION
PIPE SUPPORT LEG
PRIME AND PAINT STAND.
NO SCALE
3/8"Ø EXPANSION
BOLTS TO FLOOR
(TYP. 2 FOR EACH
LEG)
EMERGENCY DRAIN PAN,SEE DETAIL
S.A. DUCTWORK, SIZE AS
INDICATED ON PLAN
R.A. DAMPER, BALANCE TO
AIRFLOW INDICATED ON PLAN.
EQUIPMENT STAND
R.A. FILTER RACK
O.A. DUCT WITH DAMPER, SIZE AS
INDICATED ON PLAN, REFER TO
SCHEDULE AND PLANS FOR O.A. AIRFLOW
AIR HANDLING UNIT
ROOF AND CEILING
CEILING SPACE
FLEXIBLE CONNECTION
FLEXIBLE
CONNECTION
AIR CYCLER (HONEYWELL Y8150 OR APPROVED EQUAL)
R.A. REGISTER (LOCATIONS VARYPER PLAN). RA DUCT SIZED FORFULL SIZE OF UNIT CONNECTION.
EMERGENCY DRAIN PAN.SEE DETAIL ON THIS SHEET.
APPROX. 46"
THERMOSTAT/TEMPERATURE SENSOR,MOUNTED CENTERLINEWITH ADJACENT WALLSWITCHES
FINISHED FLOOR
WALL SWITCH
WALL FRAMING (TYP.)
T
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
ERIC T. SNYDER
Lic. No. 055687
02−01−17
#16244
M501
DETAILS
JBH
JBH
GG
ETS
03/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
1
1 3/15/17 B.O. CCOMMENTS
INSTALL PER THIS DETAIL WHERESPACE ABOVE CEILING IS LIMITED
CEILING DIFFUSER INSTALLATION DETAIL
DUCT SUPPORT DETAILEMERGENCY DRAIN PAN DETAIL
CONDENSATE DRAIN TRAP DETAIL
RECESSED DRYER BOX DETAIL
CONDENSATE DRAIN PIPE THRU EXTERIOR WALL DETAIL
SHEET METAL DUCT WITHEXTERIOR INSULATION
BEAD
FLEXIBLE DUCT
DIFFUSER NECK
INSULATION
CEILING
DIFFUSER
NO SCALE
DRAWBAND ORPLENUM RATEDCABLE TIE
METAL HANGER STRAP
SECURE TO BOTTOM ANDSIDES OF DUCT WITHSHEET METAL SCREWS
NOTE: FOR ANGLE SIZE AND HANGER STRAP GAUGE, SEE
SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS.
NO SCALENO SCALE
NO SCALE
DRAIN PAN TRAPPING FOR SECTION
UNDER NEGATIVE PRESSURE:
L = H + J + PIPE DIAMETER WHERE:
H = 1 INCH FOR EACH INCH OF
NEGATIVE PRESSURE PLUS 1 INCH
J = 1/2 H
DRAIN PAN TRAPPING FOR SECTION
UNDER POSITIVE PRESSURE:
L = H + J + PIPE DIAMETER WHERE:
H = 1/2 INCH (MINIMUM)
J = 1/2 INCH PLUS THE UNIT POSITIVE
STATIC PRESSURE AT COIL DISCHARGE
(LOADED FILTERS)
CLEANOUT (TYP. FOR 2)
DRAIN LINE SHALL BE ATLEAST THE SAME SIZE AS THENIPPLE ON THE DRAIN PAN
PITCH DOWNTOWARDDRAIN, ROUTEAS INDICATEDON PLAN DRAIN PANL
J
H
PROVIDE (3) 1/4"ø VENT HOLES
LENGTH SHALL BEEQUAL TO EQUIPMENTPLUS 2"
ROLL INSHARPEDGES
SECTION 'A-A'
2" MINIMUM
WELD ALL SEAMS(TYP.)
WIDTH SHALL BE EQUAL TOEQUIPMENT PLUS 2"
PAN SHALL BECONSTRUCTED OF 26 GAUGEGALVANIZED SHEET METAL
A'
A' MOISTURE SENSOR. UPONDETECTION OF MOISTURE,DE-ENERGIZE EQUIPMENT
4" DIA. EXHAUST DUCTWITHIN CHASE
RECESSED DRYER BOX
6" AFF
SECURE TOFRAMING (TYP.)
FLEXIBLE DUCT. CLAMPENDS TO DRYER BOXSLEEVE & DRYER(LENGTH AS REQ'D)
NO SCALE
FRAMING (TYP.)
1/2" GYPSUMLAPSHEATHING
RUN DOWN INSTUD WALLCAVITY FROMABOVE CEILING
CONDENSATE DRAIN PIPE
INSULATION
FACE BRICK
PIPE SLEEVE
ANCHOR
BACK-UP MATERIAL
WATERPROOF
AIR SPACE
TERMINATEOVER SPLASHBLOCK
SET SLEEVE IN WALL AND ANCHORDURING WALL CONSTRUCTION
BATT INSULATIONBETWEEN METALSTUDS
5/8"GYPSUMBOARD
INTERIOREXTERIOR
NO SCALE
*
SEALANT
NO SCALE
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
ERIC T. SNYDER
Lic. No. 055687
02−01−17
#16244
M502
DETAILS
JBH
JBH
GG
ETS
03/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA1
1
1 3/15/17 B.O. CCOMMENTS
LIGHTING
POWER
TELECOMMUNICATIONS
GENERAL
POWER (CONT.)
ELECTRICAL LEGEND
EMERGENCY RESPONDER RADIO COVERAGE NOTE
ABBREVIATIONSGENERAL ELECTRICAL NOTES
ENERGY CODE COMPLIANCE PATH
GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL WORK
SHOWN ON ELECTRICAL DRAWINGS IS NEW WORK TO BE PROVIDED
UNDER THIS CONTRACT.
COORDINATION: COORDINATE AND COOPERATE WITH ALL TRADES ON
THE PROJECT. THE CONTRACTOR SHALL REVIEW ALL CONTRACT
DOCUMENTS INCLUDING STRUCTURAL, ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS. CONTRACTOR SHALL COORDINATE AND ADJUST
ACCORDINGLY AS DIRECTED BY THE ENGINEER.
AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF ELECTRICAL
DRAWINGS TO BE KEPT ON SITE AND MARK, DAILY, THE DRAWINGS IN
RED AS THE PROJECT PROGRESSES IN ORDER TO KEEP AN ACCURATE
RECORD OF ALL DEVIATIONS BETWEEN THE WORK SHOWN ON THE
DRAWINGS AND THE WORK WHICH IS ACTUALLY INSTALLED. THESE
MARKED DRAWINGS SHALL REFLECT ANY AND ALL CHANGES AND
REVISIONS TO THE ORIGINAL DESIGN WHICH EXISTS IN THE
COMPLETED WORK. DELIVER THE MARKED DRAWINGS TO THE
ENGINEER AT PROJECT CLOSE-OUT.
TESTS: TEST ALL WIRING FOR CONTINUITY AND GROUNDS BEFORE
CONNECTING ANY FIXTURES OR DEVICES. PERFORM INSULATION
RESISTANCE TESTS ON ALL WIRING #6 OR LARGER TO INSURE THAT
ALL PORTIONS ARE FREE FROM SHORT-CIRCUITS AND GROUNDS.
INSPECTIONS: ARRANGE ALL NECESSARY INSPECTIONS. DELIVER ALL
REQUIRED INSPECTION CERTIFICATES TO THE OWNER.
ELECTRICAL SERVICE: PROVIDE THE ELECTRICAL SERVICE.
COMMUNICATE WITH THE LOCAL POWER COMPANY, VERIFY ALL
REQUIREMENTS, AND COORDINATE ALL EFFORTS.
GROUNDING: PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC
FOR THE ENTIRE ELECTRICAL SYSTEM INCLUDING EQUIPMENT FRAMES
CONDUITS, SWITCHES, CONTROLLERS, WIRE-WAYS, NEUTRAL
CONDUCTORS, AND OTHER EQUIPMENT. PROVIDE A GROUNDING
CONDUCTOR IN ALL POWER CONDUITS.
LABELS: PROVIDE LABELS FOR ALL PANELBOARDS, CABINETS, SAFETY
SWITCHES, MOTOR-DISCONNECT SWITCHES, AND MOTOR
CONTROLLERS. LABELS SHALL BE MACHINE ENGRAVED, LAMINATED
PLASTIC, PERMANENTLY ATTACHED WITH SELF-TAPPING SCREWS OR
RIVETS. DO NOT USE SELF-ADHESIVE LABELS. LABEL SHALL INDICATE
EQUIPMENT DESIGNATION AND ASSOCIATED PANEL AND CIRCUIT THAT
SERVES IT.
J-BOX LABELING: LABEL ALL JUNCTION BOXES WITH PERMANENT
MARKER IDENTIFYING CIRCUIT NUMBER AND PANELBOARD OF
CIRCUITS WITHIN.
PANEL DIRECTORY: PROVIDE TYPEWRITTEN PANELBOARD DIRECTORY
CARD IN EACH PANELBOARD WITH CIRCUIT LOAD INFORMATION AND
ROOM NUMBER CLEARLY IDENTIFIED. USE ACTUAL ROOM NUMBERS IN
THE BUILDING, NOT THE ROOM NUMBERS SHOWN ON THE CONTRACT
DRAWINGS, AS THEY ARE OFTEN DIFFERENT.
MOTOR COORDINATION: MOTORS, MOTOR STARTERS, CONTROLLERS,
INTEGRAL DISCONNECT SWITCHES, AND CONTACTORS SHALL BE
PROVIDED WITH THEIR RESPECTIVE PIECES OF EQUIPMENT BY THE
EQUIPMENT SUPPLIER. COMMUNICATE WITH THE TRADES PROVIDING
THE EQUIPMENT, VERIFYING ALL REQUIREMENTS, PROVIDE ALL
ELECTRICAL CONNECTIONS REQUIRED THEREIN, AND INSTALL MOTOR
STARTERS.
MOTOR DISCONNECTS: ALL MOTORS SHALL HAVE DISCONNECTING
MEANS.
MOTOR FUSE PROTECTION: WHERE FUSE PROTECTION IS
SPECIFICALLY REQUIRED BY THE EQUIPMENT MANUFACTURER,
PROVIDE FUSED SWITCHES IN LIEU OF NON-FUSED SWITCHES OR IN
LIEU OF ENCLOSED CIRCUIT BREAKERS, OR OTHER DEVICES
INDICATED.
CONNECTION DETAILS: SECURE APPROVED SHOP DRAWINGS
SHOWING WIRING DIAGRAMS, ROUGH-IN AND HOOK UP DETAILS FROM
OTHER INVOLVED CONTRACTORS FOR EQUIPMENT WHICH MUST BE
CONNECTED ELECTRICALLY.
COORDINATION DETAILS: MECHANICAL EQUIPMENT WILL BE
FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. THE
LOCATIONS SHOWN ON THE ELECTRICAL DRAWINGS ARE
APPROXIMATE. COORDINATE WITH THE MECHANICAL CONTRACTOR TO
DETERMINE THE EXACT LOCATION OF EACH PIECE OF EQUIPMENT AND
DETERMINE THE EXACT ROUGH-IN AND CONNECTION REQUIREMENTS.
WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF
ELECTRICAL EQUIPMENT WITH MECHANICAL DUCTWORK, PIPING ETC.
AND ASSURE WORKING CLEARANCE REQUIRED BY NEC WILL BE MET.
SUFFICIENT ACCESS AND WORKING SPACE SHALL BE PROVIDED AND
MAINTAINED AROUND ELECTRICAL EQUIPMENT AS REQUIRED BY THE
NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL COORDINATE
FINAL LOCATION OF EQUIPMENT PROVIDED AND INSTALLED BY OTHER
TRADES.
STARTER MOUNTING: WHERE AN INDIVIDUALLY MOUNTED SAFETY
SWITCH, STARTER OR CIRCUIT BREAKER IS SHOWN ADJACENT TO ITS
RESPECTIVE LOAD AND NOT MOUNTED ON A WALL, PROVIDE ALL
SUPPORTS, BRACKETS, ANCHORING, ETC. NECESSARY TO PROPERLY
SUPPORT THE DEVICE.
LIGHTING ARRANGEMENT: ARRANGE LIGHTING FIXTURES IN
ACCORDANCE WITH THE ARCHITECTURAL REFLECTED CEILING PLANS.
LIGHTING COORDINATION: COORDINATE LIGHTING FIXTURES WITH
GRILLES, DIFFUSERS, SPRINKLER HEADS, AND ACCESS PANELS, ETC.
PROVIDE FIXTURE MOUNTING BRACKETS, ACCESSORIES, PLASTER
FRAMES, ETC.. SUITABLE FOR THE CEILING TYPES INDICATED ON THE
ARCHITECTURAL PLANS.
MATERIAL COORDINATION: VERIFY CEILING AND WALL
CONSTRUCTION AND MATERIAL PRIOR TO ORDERING LIGHT FIXTURES
OR OTHER DEVICES TO INSURE PROPER FIXTURE OR DEVICE IS
FURNISHED TO MATCH CONSTRUCTION.
MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE
FINISHED FLOOR TO THE CENTERLINE OF THE WIRING DEVICE UNLESS
OTHERWISE NOTED. MOUNTING HEIGHTS OF LIGHTING FIXTURES ARE
TO THE BOTTOM OF THE FIXTURE UNLESS OTHERWISE NOTED.
DEVICE LOCATIONS: COORDINATE LOCATIONS OF SWITCHES,
RECEPTACLES, AND TELE/DATA OUTLETS WITH OTHER WALL MOUNTED
DEVICES SUCH AS THERMOSTATS AND CONTROL STATIONS.
EWC RECEPTACLES: RECEPTACLES FOR ELECTRIC WATER COOLERS
(EWC) SHALL BE INSTALLED OUT OF VIEW AND BEHIND THE EWC
ENCLOSURE. VERIFY THE MOUNTING HEIGHT WITH THE EQUIPMENT
SUPPLIER PRIOR TO ROUGH-IN.
DEVICE COORDINATION: THOROUGHLY REVIEW AND COORDINATE ALL
CASEWORK AND CABINET DRAWINGS AND ARCHITECTURAL
ELEVATIONS WITH DEVICE LOCATIONS PRIOR TO ROUGH-IN OF OUTLET
BOXES.
BARRIERS: WHERE A MULTIPLE-GANG BOX HAS CIRCUITS OF
DIFFERENT VOLTAGES OR SYSTEMS WHICH ARE REQUIRED TO BE
SEPARATED, PROVIDE THE CODE-REQUIRED SEPARATION USING A
FULL HEIGHT AND DEPTH BARRIER PLATE.
CLEAN UP: ON PROJECT CLOSE-OUT CLEAN ALL ELECTRICAL DEVICES,
LIGHTING FIXTURES, AND LENSES, AND REMOVE ALL PAINT SPATTERS
FROM DEVICES, FIXTURES AND PLATES. REPLACE ALL INOPERATIVE
FIXTURES.
CONTRACTOR SHALL PROVIDE A MINIMUM OF ONE OF THE FOLLOWING COURSES OF ACTION.
1. ENGAGE A QUALIFIED TESTING AGENCY TO VERIFY EMERGENCY RESPONDER COMMUNICATIONS SIGNAL LEVELS IN
ALL AREAS OF THE BUILDINGS ONCE ALL STRUCTURAL STEEL AND CONCRETE HAS BEEN CONSTRUCTED.
2. ENGAGE CITY OF HENRICO COUNTY EMERGENCY RESPONSE GROUPS (FIRE, POLICE, EMS) AND HAVE THEM TEST
THEIR SPECIFIC EQUIPMENT IN ALL AREAS OF THE BUILDINGS ONCE ALL STRUCTURAL STEEL AND CONCRETE HAS
BEEN CONSTRUCTED.
IF SIGNAL LEVELS ARE BELOW COMMUNICATIONS EQUIPMENT MANUFACTURER'S STANDARDS, THEN THE SIGNALS SHALL
BE SUPPLEMENTED IN ALL DEFICIENT AREAS OF THE SITE IN ACCORDANCE WITH PARAGRAPH BELOW.
PROVIDE A COMPLETE RADIATING CABLE SYSTEM CONSISTING OF COAXIAL CABLE OR EQUIVALENT ABOVE ACCESSIBLE
CEILINGS (PREFERABLY SERVICE CORRIDORS) TO PROVIDE A SUPPORTING CABLE INFRASTRUCTURE FOR THE ADDITION
OF A BUILDING DISTRIBUTION AMPLIFIER TO PERPETUATE CONTINUOUS EMERGENCY COMMUNICATION WITHIN THE
BUILDING(S). THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE CABLE EVERYWHERE NECESSARY TO
ENSURE ADEQUATE COMMUNICATION IS ATTAINED IN ALL AREAS OF THE BUILDING(S). A 4' X 4' SPACE ON THE TELEPHONE
BACKBOARD(S) SHALL BE ALLOCATED IN THE MAIN TELECOMMUNICATIONS DISTRIBUTION LOCATION(S) FOR THE
AMPLIFIER AND ALL CABLE WILL BE RUN BACK TO THIS LOCATION. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR
PROVIDING A PATHWAY (1"C MINIMUM) FROM THE AMPLIFIER LOCATION TO THE ROOF (THROUGH A PITCH POCKET) FOR
THE POTENTIAL ADDITION OF A RADIO SYSTEMS ANTENNA. CONTRACTOR SHALL ENGAGE THE SERVICES OF A QUALIFIED
RADIO COMMUNICATIONS CONTRACTOR TO PROVIDE A COMPLETE DESIGN. DESIGN, INSTALLATION, AND TESTING SHALL
CONFORM WITH REQUIREMENTS OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE 2012, SECTION 510 OF THE
INTERNATIONAL FIRE CODE 2012, EMERGENCY RESPONDER RADIO COVERAGE. THE COST OF THE DESIGN AND THE
INSTALLATION OF THIS SYSTEM SHALL BE INCLUDED AS A SEPARATE ADDITIVE BID ITEM.
3
4
D
OC
TV
TMGB
E
A
P
1
LIGHTING FIXTURE
EMERGENCY LIGHTING FIXTURE WITH EMERGENCY BATTERY - CONNECTBATTERY AHEAD OF LOCAL SWITCH.
DOWNLIGHT OR PENDANT MOUNTED FIXTURE
EXIT LIGHTING FIXTURE, WITH DIRECTIONAL ARROWS AS INDICATED WITHBATTERY PACK - CONNECT AHEAD OF LOCAL SWITCH.
LIGHTING FIXTURE TYPE SYMBOL. SEE LIGHTING FIXTURE DETAILS.
SINGLE POLE SWITCH, 20A, 120/277V, 46" AFF UON
THREE-WAY SWITCH, 20A, 120/277V, 46" AFF UON
DIMMER SWITCH, 46" AFF UON. FOR L.E.D. FIXTURES, COORDINATEVOLTAGE AND RATINGS OF SWITCH WITH TYPE AND QUANTITY OFDRIVERS TO BE CONTROLLED.
EQUIPMENT CONNECTION
MOTOR CONNECTION
SAFETY SWITCH, 60A-3P, FU @ 30A, 3R
ELECTRICAL PANELBOARD
ELECTRICAL CIRCUIT RUN IN CONDUIT AND CIRCUIT HOMERUN TOPANELBOARD (PANEL AND CIRCUIT DESIGNATION AS INDICATED). AS AMINIMUM CONDITION, EACH SINGLE PHASE CIRCUIT SHALL HAVE 1 #12PHASE CONDUCTOR, 1 #12 NEUTRAL CONDUCTOR AND 1 #12 GROUNDINGCONDUCTOR IN 1/2" CONDUIT. PROVIDE ADDITIONAL PHASE CONDUCTORSAS REQUIRED FOR "MULTIPLE PHASED" ELECTRICAL LOADS. PROVIDENEUTRAL CONDUCTOR TO ALL WALL SWITCH OUTLET BOXES WHETHERREQUIRED OR NOT. PROVIDE ADDITIONAL "SWITCH LEG" CONDUCTORSTO PROVIDE THE LIGHT FIXTURE CONTROL INDICATED. MULTIPLE SINGLEPHASE CONDUCTORS MAY BE GROUPED TOGETHER IN A COMMONCONDUIT IN ACCORDANCE WITH THE NEC AND AT THE CONTRACTOR'SDISCRETION. GROUNDING CONDUCTORS MAY BE SHARED AS ALLOWEDBY THE NEC. NEUTRAL CONDUCTORS SHALL NOT BE SHARED.MULTI-POLE BREAKERS SHALL BE PROVIDED IN ACCORDANCE WITH THENEC SHOULD MULTI-WIRE BRANCH CIRCUITS BE INSTALLED. CONDUITLARGER THAN 1/2" AND CONDUCTORS LARGER THAN #12 SHALL BE ASINDICATED.
WALL MOUNTED LIGHTING FIXTURE
FOUR-WAY SWITCH, 20A, 120/277V, 46" AFF UON
DRYER RECEPTACLE, NEMA 11-30R
NEW WORK NOTE SYMBOL
PHOTOCELL, 1500W, 120V SPST, MOUNT ON ROOF, AIM NORTH
WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR WITH SINGLEPOLE SWITCH, 120/277V, MOUNT 46"AFF.
TELECOMMUNICATIONS BACKBOARD - 4'W x 8'H x 3/4"THICK
MAIN GROUND BUS BAR
SWITCH RATINGNUMBER OF POLESFUSE RATING (NF INDICATES NON-FUSED)NEMA ENCLOSURE IF OTHER THAN NEMA 1
AND
THE FOLLOWING SUBSCRIPTS SHALL APPLY TO RECEPTACLES WHERE USED:
DUPLEX CONVENIENCE RECEPTACLE 20A, 120V, 18" AFF, UON
TWO DUPLEX RECEPTACLES IN COMMON BOX, EACH 20A, 120V, 18" AFF, UON
DUPLEX CONVENIENCE RECEPTACLE 20A, 120V, 46" AFF, UON (OR 6" ABOVECOUNTER AS APPLICABLE)
· GFI: GROUND FAULT INTERRUPTING TYPE RECEPTACLE
· +XX": DEVICE MOUNTING HEIGHT DESIGNATION ABOVE FINISHED FLOOR IF
OTHER THAN 18" OR 46".
· TV: TELEVISION RECEPTACLE, COORDINATE MOUNTING HEIGHT WITH
TELEVISION MOUNTING BRACKET.
· WP: WEATHER RESISTANT GFI RECEPTACLE WITH RECCESSED WEATHERPROOF
WHILE-IN-USE COVER.
· EWC: ELECTRIC WATER COOLER RECEPTACLE, GROUND FAULT INTERRUPTING
TYPE. LOCATE BEHIND THE EWC PER MANUFACTURER'S RECOMMENDATIONS.
ASHRAE 90.1
VECC CHAPTER 4 - PRESCRIPTIVE
VECC CHAPTER 4 - PERFORMANCE
CEILING MOUNTED DUAL TECHNOLOGY ULTRASONIC/PASSIVE INFRAREDVACANCY SENSOR.
VS
TELEPHONE OUTLET, 4"X4"X2 1/8"D BOX WITH SINGLE GANG AND SINGLEGANG COVERPLATE TO MATCH ELECTRICAL, 54" AFF, UON, WITH CAT-6CABLE BACK TO TELECOMMUNICATIONS BACKBOARD.
TELE/DATA OUTLET, 4"X4"X2 1/8"D BOX WITH SINGLE GANG AND SINGLEGANG COVERPLATE TO MATCH ELECTRICAL, 18" AFF, UON, WITH (2)CAT-6 CABLES BACK TO TELECOMMUNICATIONS BACKBOARD.
TELEVISION (TV) OUTLET, 3 5/8"X2 1/4"X3 1/4"D, 18" AFF, UON, PROVIDERG-6 BACK TO TELECOMMUNICATIONS BACKBOARD. WHERE OUTLET ISADJACENT TO A POWER RECEPTACLE, MOUNT AT SAME ELEVATION ASPOWER RECEPTACLE, UON.
A AMPERE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CAPACITY
C CONDUIT
CKT CIRCUIT
CB CIRCUIT BREAKER
DVP DOMINION VIRGINIA POWER
EBU EMERGENCY BATTERY UNIT
EC EMPTY CONDUIT
ECB ENCLOSED CIRCUIT BREAKER
EF EXHAUST FAN
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
FHP FRACTIONAL AC HORSEPOWER
FLA FULL LOAD AMPS
GFI GROUND FAULT INTERRUPTER
GND GROUND
HP HORSE POWER/HEAT PUMP
KAIC THOUSAND AMPEREINTERRUPTING CAPACITY
KVA KILO-VOLT-AMPERES
KW KILO-WATTS
LPW LUMENS PER WATT
LTG LIGHTING
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MFR MANUFACTURER
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON-FUSED
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED,CONTRACTOR INSTALLED
P POLE
PL PROPERTY LINE
PNL PANEL
PNLBD PANELBOARD
Ø PHASE
PRI PRIMARY
RECEPT RECEPTACLE
REQ'D REQUIRED
SE SERVICE ENTRANCE
SEC SECONDARY
TBB TELEPHONE BACKBOARD
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VOLT
W WATTS/WIRE
WP WEATHERPROOF
WALL MOUNTED LOW VOLTAGE MOMENTARY CONTACT SWITCH, 24VDC,MOUNT 46"AFF.
LV
WALL MOUNTED LOW VOLTAGE MOMENTARY CONTACT SWITCH WITHDIMMING CAPABILITIES, 24VDC, MOUNT 46"AFF.
DLV
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JAMES S. BEDOIS
Lic. No. 032929
#16244
E001
LEGEND, NOTES
AND
ABBREVIATIONS
KPM
SAL
JEB
JEB
3/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
1 3/15/17 B.O. COMMENTS
2/1/17
OC
OC
DLVDLV3
OC
OC
OC
LV
D
LV
3
LV
VS VS
LV
D
3
VS
3
VS
VS
4
VS
DLV
2
16
13
12
11
10
3
8 7
6
5
9
14
1
15
A
A
B
A
DD
A
CC
A
A
B (TYP, UON)
A
A
B
B
D
D
A
A
A
A
C
C C
A
A
W
W
W
W
C1
CH1-9
CH1-11; 2 #10, 1 #10 GND - 1/2"C VIA PHOTOCELL
CH1-13
B
4
PANEL "CH1"
PANEL "MDPC"
K
K
W
P
MOUNT ON ROOF AND AIM NORTH
1/4" = 1'-0"5' 10'0' 5'
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JAMES S. BEDOIS
Lic. No. 032929
#16244
GRAPHIC SCALE:
E101
FIRST FLOOR
LIGHTING PLAN
KPM
SAL
JEB
JEB
3/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
SCALE: 1/4" = 1'-0"
FIRST FLOOR LIGHTING PLAN
1ST FLOOR ROOM
SCHEDULE
1 COMMUNITY ROOM
2 KITCHENETTE
3 RECEPTION
4 WORK ROOM
5 CONF ROOM
6 FILES
7 MECH/ELC
8 STORAGE
9 CORRIDOR
10 MECH/JANITOR CLOSET
11 H/C WOMEN'S TOILET
12 H/C MEN'S TOILET
13 LAUNDRY
14 FITNESS
15 MAINT SHOP
16 VESTIBULE
1 3/15/17 B.O. COMMENTS
2/1/17
1
1
GFI
GFI
EWC
GFI GFI
TV
TV
TV
TV
TV
TV
36"
WP
WP
WP
WP
WP
WP
2
16
13
12
11
10
3
8
7
6
5
9
14
1
E
15
1
2
TM
GB
3
MDPC-2
MDPC-6
MDPC-10
WH-1, 4.5KW, 240V, 1Ø
CH1-1
CH1-2
CH1-3
CH1-4
CH1-6
CH1-10
CH1-12CH1-5
CH1-14 CH1-16 CH1-18
CH1-7
30A-2P, NF
MDPC-31; 2 # 10,1 #10 GND - 1/2"C
EE
HP-1, 12MCA, 240V, 1ØHP-3, 44MCA, 240V, 1Ø
60A-2P, FU@60A, 3R 30A-2P, FU@15A, 3R
MDPC-35; 2 #10, 1 #10 GND - 1/2"C
MDPC-36; 2 #6, 1 #10 GND - 1/2"C
EE30A-2P, FU@30A, 3R
AHU-1, 29MCA, 240V, 1Ø
100A-2P, FU@100A, 3R
AHU-3, 97MCA, 240V, 1Ø
MDPC-39; 2 #1, 1 #8 GND - 1 1/2"C MDPC-40; 2 #10,
1 #10 GND - 1/2"C
E
HP-2, 21MCA, 240V, 1Ø
60A-2P, FU@35A, 3R
MDPC-28; 2 #8, 1 #10 GND - 3/4"C
E30A-2P, FU@30A, 3R
AHU-2, 29MCA, 240V, 1Ø
MDPC-32; 2 #10, 1 #10 GND - 1/2"C
EF-1, 60W, 120V
MDPC-1
MDPC-3
4
4
4
DRYER, 240V
WASHER, 120V
CH1-8CH1-20
CH1-22
5
MICROWAVE, 120V
4
METER
PANEL "CH1"
PANEL "MDPC"
CH1-30
6
CH1-20
CH1-15
DISHWASHER, 120V
CH1-17
CH1-24
CH1-26
MDPC-5
EF-2, 1/2HP, 120V
1 REFRIGERATOR, 120V.
COPIER, 120V.
(2) 4"C STUBBED OUT TO PROPERTY LINE FOR INCOMING TELECOMMUNICATIONS SERVICE.
2 #10, 1 #10 GND - 1/2"C.
MOUNT RECEPTACLES HORIZONTALLY IN BACKSPLASH.
TREADMILL, 120V.
2
3
4
5
6
1/4" = 1'-0"5' 10'0' 5'
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JAMES S. BEDOIS
Lic. No. 032929
#16244
GRAPHIC SCALE:
E201
FIRST FLOOR
POWER PLAN
KPM
SAL
JEB
JEB
3/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
SCALE: 1/4" = 1'-0"
FIRST FLOOR POWER PLAN
1ST FLOOR ROOM
SCHEDULE
1 COMMUNITY ROOM
2 KITCHENETTE
3 RECEPTION
4 WORK ROOM
5 CONF ROOM
6 FILES
7 MECH/ELC
8 STORAGE
9 CORRIDOR
10 MECH/JANITOR CLOSET
11 H/C WOMEN'S TOILET
12 H/C MEN'S TOILET
13 LAUNDRY
14 FITNESS
15 MAINT SHOP
16 VESTIBULE
NOTES THIS SHEET
1 3/15/17 B.O. COMMENTS
2/1/17
1
1
1
1 1
1
1
1
1
NOTES:
1. WIRING PER MANUFACTURER'S RECOMMENDATION.
2. ALL CABLE SHALL BE PLENUM RATED.
3. DEVICE QUANTITIES SHALL BE DETERMINED FROM FLOOR PLANS. QUANTITIES SHOWN ON
THIS DIAGRAM ARE REPRESENTATIVE ONLY.
4. ENSURE CABLING IS SUPPORTED AT MAX. OF 48" ON CENTER.
MDPC CH1
NO SCALENO SCALE
TVTMGB
PANEL
400A MCB120/240V1Ø, 3W
PANEL
125A MLO120/240V1Ø, 3W
N G
TELECOMMUNICATIONS RISER DIAGRAMPOWER RISER DIAGRAM
FAULT CURRENT NOTE:
FIRST FLOOR
INCOMING CABLE SERVICE BYLOCAL SERVICE PROVIDER
(2) CAT-6 CABLES
RG-6 CABLE
INCOMING TELECOMMUNICATIONSSERVICE BY LOCAL SERVICE PROVIDER
STUB (2) 4"C OUT TOPROPERTY LINE FORINCOMING SERVICESMIN 18" BFG.
CAT-6 CABLE
ROOF
#3/0 GND - 1"C TO UNDERGROUND WATERSERVICE METALLIC PIPE
#3/0 GND - 1"C TO CONCRETE ENCASEDELECTRODE
#3/0 GND - 1"C TOGROUND ROD
(2) 4"EC TO DVP PADMOUNTEDTRANSFORMER
3-500 KCMIL, 1 #2 GND - 3"C
TELECOM/IT
ROOMMETER
PROVIDE ALL 120/240V PANELS & METER STACKS WITH A SHORT CIRCUIT RATING OF 35KAIC. CONTACT THE LOCAL POWER COMPANY PRIOR TO SUBMITTING SHOP DRAWINGSAND IF THE AVAILABLE FAULT CURRENT IS LESS THAN OR MORE THAN THIS AMOUNT, THENNOTIFY THE OWNER IN WRITING & PROVIDE APPROPRIATE POWER EQUIPMENT. UL LISTEDSERIES RATINGS MAY BE APPLIED WHERE APPROPRIATE.
TYPICAL GROUND BUS BAR DETAIL
CO
NTR
OL
OU
TPU
T 24
VD
C
CO
NTR
OL
RE
TUR
N
+24
VD
C
CO
NTR
OL
OU
TPU
T 24
VD
C
CO
NTR
OL
RE
TUR
N
+24
VD
C
NO SCALE
COPPER BASED BOLTS, NUTS, &LOCK WASHERS (TYPICAL)
STAND-OFF INSULATOR, 1KVMINIMUM (2" MINIMUM OFFSET)(TYPICAL)
FACTORY DRILLED HOLES (TYPICAL)
MOUNTING BRACKETS (TYPICAL)
TBB IN 3/4"C. CONNECT TO ELECTRICALPANEL GROUND ELECTRODE SYSTEM PERNEC ARTICLE 800
COPPER MAIN TELECOMMUNICATIONS
GROUND BUS BAR ( )
4" x 12" x 1/4" THICK (TYPICAL)
NO SCALE
TMGB
VS
LV VS
CEILING VACANCY SENSOR WIRING DIAGRAM ( )
750kcmil
76 - 91 ( 251 - 300 )
GREATER THAN 91 ( 301 )
600kcmil
500kcmil
350kcmil
250kcmil
300kcmil
4/0
20 - 26 ( 67 - 84 )
32 - 38 ( 106 - 125 )
38 - 46 ( 126 - 150 )
46 - 53 ( 151 - 175 )
53 - 76 ( 176 - 250 )
26 - 32 ( 85 - 105 )
TBC - TELECOMMUNICATIONS BONDING CONDUCTOR
TBB - TELECOMMUNICATIONS BONDING BACKBONE
3/0
2/0
1/0
1
2
16 - 20 ( 53 - 66 )
13 - 16 ( 42 - 52 )
10 - 13 ( 34 - 41 )
8 - 10 ( 27 - 33 )
3
4
6 - 8 ( 21 - 26 )
6
4 - 6 ( 14 - 20 )
LESS THAN 4 (13)
TBB/TBC SIZE (AWG)TBB/TBC LENGTH M (FT)
CONTRACTOR SHALL SIZE TELECOMMUNICATIONS
GROUNDING AND BONDING INFRASTRUCTURE PER
ANSI J-STD-607-B
POWER PACK
DRIVER
TO ADDITIONALLIGHT FIXTURES INSAME ROOM
NEUTRAL
VACANCYSENSOR ,TYPICAL
LOW VOLTAGE MOMENTRAY CONTACTWALL MOUNTED SWITCH(ES) ( )
BATTERY PACKEMERGENCY
HOT
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JAMES S. BEDOIS
Lic. No. 032929
#16244
E501
DETAILS AND
SCHEDULES
KPM
MIN
JEB
JEB
3/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
1 3/15/17 B.O. COMMENTS
TOTAL CONNECTED AMPS A: 107.4 B: 87.6
TOTAL 44.4 36.6 63.0 51.0 TOTAL
SPARE 20/1P 29 30 20/1P 12.0 RECEPTACLES
SPARE 20/1P 27 28 20/1P 3.0 RECEPTACLES
SPARE 20/1P 25 26 20/1P 1.5 RECEPTACLES
SPARE 20/1P 23 24 20/1P 3.0 TELECOM
SPARE 20/1P 21 22 20/1P 1.5 RECEPTACLES
SPARE 20/1P 19 20 20/1P 3.0 RECEPTACLES
EXTERIOR REC. 9.0 20/1P 17 18 20/1P 10.0 WASHER
DISHWASHER 10.0 20/1P 15 16 20/1P 10.0 WASHER
LIGHTING 11.9 20/1P 13 14 20/1P 10.0 WASHER
EXTERIOR LIGHTING 2.6 20/1P 11 12 20/1P 12.0 REFRIGERATOR
LIGHTING 8.5 20/1P 9 10 20/1P 6.0 EWC
RECEPTACLES 10.5 20/1P 7 8 20/1P 10.0 MICROWAVE
GFI RECEPTACLES 4.5 20/1P 5 6 20/1P 10.0 TREADMILL
RECEPTACLES 13.5 20/1P 3 4 20/1P 10.0 TREADMILL
RECEPTACLES 10.5 20/1P 1 2 20/1P 12.0 COPIER
LOAD SERVED A B TRIP NO. A B NO. TRIP A B LOAD SERVED
LOAD (AMPS) BKR CKT PHASE CKT BKR LOAD (AMPS)
SEE POWER RISER DIAGRAM FOR RATINGS
PANELBOARD CH1 SCHEDULE
TOTAL CONNECTED AMPS A: 385.7 B: 395.7
TOTAL 151.5 161.5 234.2 234.2 TOTAL
23.2 32.8
AHU-1 23.2 30/2P 39 40 45/2P 32.8 AHU-2
9.6 16.8
HP-1 9.6 15/2P 35 36 35/2P 16.8 HP-2
18.8 77.6
WH-1 18.8 30/2P 31 32 100/2P 77.6 AHU-3
87.6 35.0
PANEL CH1 107.4 125/2P 27 28 60/2P 35.0 HP-3
SPARE 20/1P 25 26 20/1P SPARE
SPARE 20/1P 23 24 20/1P SPARE
SPARE 20/1P 21 22 20/1P SPARE
SPARE 20/1P 19 20 20/1P SPARE
SPARE 20/1P 17 18 20/1P SPARE
SPARE 20/1P 15 16 20/1P SPARE
SPARE 20/1P 13 14 20/1P SPARE
SPARE 20/1P 11 24.0
SPARE 20/1P 9 10 30/2P 24.0 DRYER
SPARE 20/1P 7 24.0
EF-2 9.8 20/1P 5 6 30/2P 24.0 DRYER
EF-1 2.5 20/1P 3 24.0
EF-1 2.5 20/1P 1 2 30/2P 24.0 DRYER
LOAD SERVED A B TRIP NO. A B NO. TRIP A B LOAD SERVED
LOAD (AMPS) BKR CKT PHASE CKT BKR LOAD (AMPS)
SEE POWER RISER DIAGRAM FOR RATINGS
PANELBOARD MDPC SCHEDULE
1. 1st 10 KVA @ 100%, REMAINDER @ 50%
NOTES:
TOTAL 89.7 KVA 76.9 KVA
CUSTOM LOAD 0.0 KVA 100% 0.0 KVA
ELEVATOR 0.0 KVA 100% 0.0 KVA
WATER HEATER 4.5 KVA 100% 4.5 KVA
KITCHEN EQUIP. 0.0 KVA 100% 0.0 KVA
COOKING EQUIP. 0.0 KVA 100% 0.0 KVA
MISCELLANEOUS 0.0 KVA 100% 0.0 KVA
VENTILATION 0.0 KVA 100% 0.0 KVA
HEAT PUMP 14.7 KVA 100% 14.7 KVA
HEATING 0.0 KVA 100% 0.0 KVA
AIR CONDITIONING 32.1 KVA 100% 32.1 KVA
RECEPTACLES 35.6 KVA NOTE - 1 22.8 KVA
EXTERIOR LIGHTING 0.3 KVA 100% 0.3 KVA
LIGHTING 2.4 KVA 100% 2.4 KVA
DESCRIPTION LOAD FACTOR LOAD
LOAD CONNECTED DEMAND DEMAND
ELECTRICAL LOAD SUMMARY
2/1/17
1
1
DETAIL BASED ON LITHONIA LIGHTING "STL4 " SERIES
2-11/16"
24"
LUMINAIRE REQUIREMENTS
1.
2.
HOUSING SHALL BE PAINTED OR PLATED SOLID ALUMINUM WITH A 1/8" MATTE WHITEEXTRUDED ACRYLIC PANEL.
FIXTURE SHALL BE APPROXIMATELY 46" LONG.
4. THE LENS SHALL BE HIGH IMPACT PEARLESCENT ACRYLIC. SMOOTH EXTERIOR,LINEAR PRISMATIC INTERIOR. NOMINAL THICKNESS .156". LENS LOCK IN PLACE WITHTAMPER-RESISTANT STAINLESS STEEL POSIGRIP FASTENERS.
5.
FIXTURE SHALL BE UTILIZED WITH ELECTRONIC DRIVER.
3.
FIXTURE SHALL BE UL LISTED FOR DAMP LOCATIONS.
PROVIDE WITH EMERGENCY OPTION WHEN INDICATED WITH " ".6.
16"11"
52
LUMINAIRE REQUIREMENTS:
SURFACE, WALL, 8" AFG1204000K LED
DETAIL BASED ON PHILLIPS LIGHTING, "101L" SERIES
5021
1. FIXTURE SHALL BE DIE CAST ALUMINUM HOUSING, WITH STAINLESS STEEL
HARDWARE, AND FULLY GASKETED.
2. LENS SHALL BE IMPACT RESISTANT TEMPERED GLASS. DRIVER SHALL BE HIGH
PERFORMANCE ELECTRONIC LED INTEGRAL DRIVER.
3. PROVIDE WITH 10kv SURGE PROTECTOR.
4. FINISH SHALL BE POLYESTER POWDER COAT, IMPACT, CORROSION AND UV
RESISTANCE. COORDINATE FINISH COLOR WITH ARCHITECT.
5. UL LISTED AND DAMP LOCATION LISTED AND TESTED IN ACCORDANCE WITH IESNA
LM-79 AND LM-80 STANDARDS AND FOR WET LOCATIONS.
6. PROVIDE FIXTURE TYPE WITH TYPE 3 DISTRIBUTION.
7. PROVIDE WITH EMERGENCY OPTION WHEN INDICATED WITH " ".
42
LUMINAIRE REQUIREMENTS:
SURFACE, WALL, 8" AFG
1. FIXTURE SHALL BE DIE CAST ALUMINUM HOUSING, WITH STAINLESS STEEL
HARDWARE, AND FULLY GASKETED.
PERFORMANCE ELECTRONIC LED INTEGRAL DRIVER.
3. PROVIDE WITH 10kv SURGE PROTECTOR.
4. FINISH SHALL BE POLYESTER POWDER COAT, IMPACT, CORROSION AND UV
RESISTANCE. COORDINATE FINISH COLOR WITH ARCHITECT.
5. UL LISTED AND DAMP LOCATION LISTED AND TESTED IN ACCORDANCE WITH IESNA
LM-79 AND LM-80 STANDARDS AND FOR WET LOCATIONS.
1204000K LED
DETAIL BASED ON LIGHTWAY, "MANW-LED" SERIES
4900
2. LENS SHALL BE EXTRUDED WHITE ACRYLIC. DRIVER SHALL BE HIGH
6. PROVIDE FIXTURE WITH EMERGENCY BATTERY BACK-UP WHERE INDICATED.
LED LENSED STRIPSURFACE MOUNTED LED 2X2 RECESSED LED TROFFER
EDGE-LIT EXIT LIGHT
RECESSED 6" LED OPEN DOWNLIGHT
LED WALLPACKLED WALL SCONCE
DA CB
W
C
C1
C1
K
DETAIL BASED ON LITHONIA LIGHTING, "ZL 1N" SERIES
LUMINAIRE DESCRIPTION:
1. HOUSING SHALL BE 0.026" THICK (MINIMUM) DIE FORMED COLD ROLLED STEEL, CHEMICALLY
TREATED FOR RUST PREVENTION, AND FINISHED WITH WHITE BAKED ENAMEL OR POLYESTER
FINISH. PROVIDE TOP AND END KNOCKOUTS IN FIXTURE AND METAL END PLATES.
2. HOUSING SHALL BE WELDED OR SECURED BY SCREWS, RIVETS, OR SNAP TOGETHER TABS
AND SLOTS, INTO A SINGLE ASSEMBLY.
3. LUMINAIRE SHALL BE CAPABLE OF CONTINUOUS ROW AND SINGLE UNIT PLACEMENT WITH
PENDANT OR SURFACE MOUNTING.
4. FIXTURE SHALL HAVE ELECTRONIC DRIVER.
5. FIXTURE SHALL HAVE SNAP ON ACRYLIC DIFFUSER
6. FIXTURE SHALL BE UL LISTED.
TYPE LUMEN LAMP TYPE VOLTAGE MOUNTING
CEILING, SURFACE12042W4000K LED5000
48"
2 1/8"
2 1/8"
INPUT WATTS
10"
4"
46"
SURFACE, CEILING
**THIS FIXTURE MEETS DLC REQUIREMENTS
MOUNTING
45W
INPUT WATTS VOLTS
1204000K LED
LAMP TYPELUMEN
4124
TYPE
DETAIL BASED ON DAY-BRITE LIGHTING, "DUALED 2SDL" SERIES
LUMINAIRE DESCRIPTION:
1. HOUSING SHALL BE 20 GAUGE STEEL WITH WHITE POLYESTER POWDER COAT FINISH.
2. FIXTURE SHALL HAVE SOFT OPAL DIFFUSER.
3. HIGH EFFICIENCY INTEGRAL DRIVER. DRIVER AND LEDS EASILY ACCESSIBLE FROM BELOW.
4. UL LISTED FOR DAMP LOCATION AND TESTED IN ACCORDANCE WITH IESNA LM-79 AND
LM-80 STANDARDS.
5. DRIVER SHALL PROVIDE 0-10V DIMMING TO 10%.
6. FIXTURE TYPE SHALL BE SURFACE MOUNTED.
7. FIXTURE TYPE SHALL BE RECESSED.
TYPE LUMENS LAMP TYPE INPUT WATTS VOLTAGE MOUNTING
24"
RECESSED, SURFACE CEILING120454000K LED3400
DETAIL BASED ON DUAL-LITE LIGHTING, "LE" SERIES
LUMINAIRE DESCRIPTION:
1. ALUMINUM HOUSING WITH HIGH-POLISH,
INJECTION-MOLDED VIRGIN ACRYLIC EDGE-LIT
PANEL. GRADUATED DEPTH OF MOLDED
LETTERS PROVIDES UNIFORM LIGHT
DISTRIBUTION ON GRAPHICS.
2. 6" TALL LETTERS.
3. RED ILLUMINATION PROVIDED BY LIGHT
EMITTING DIODES (LED).
4. POWER FAILURE PROTECTION, BROWN OUT
PROTECTION, AND SURGE PROTECTION.
5. SEALED, MAINTENANCE FREE, NICKEL CADMIUM
BATTERY WITH SOLID STATE CHARGER AND
OVERCHARGE PROTECTION.
6. DIRECTIONAL ARROWS AS INDICATED.
7. UNIVERSAL MOUNTING.
8. TEST BUTTON IN BOTTOM OF HOUSING.
9. INDICATOR LIGHTS IN FACE TO INDICATE WHEN
UNIT IS ON NORMAL POWER OR ON BATTERY
POWER.
10. BRUSHED ALUMINUM AND CLEAR ACRYLIC
FINISH.
TYPE LAMP TYPE VOLTAGE MOUNTING
CEILING, WALL; UNIVERSALMOUNT.
1205LED
7-1/2"
14"
INPUT WATTS
DETAIL BASED ON PHILLIPS LIGHTING, "CALCULITE" SERIES
LUMINAIRE DESCRIPTION:
1. RECESSED DOWNLIGHT THAT PROVIDES VOLUMETRIC LIGHTING.
2. 16-GAUGE GALVANIZED STEEL MOUNTING PAN AND YOKE ASSEMBLY.
3. REFLECTOR IS DIE-FORMED OF 0.40 LOW IRIDESCENT ALUMINUM AND SELF-FLANGED.
4. GALVANIZED STEEL JUNCTION BOX WITH BOTTOM-HINGED ACCESS COVERS AND SPRING
LATCHES. TWO COMBINATIONS 1/2"-3/4" AND THREE 1/2" KNOCKOUTS FOR
STRAIGHT-THROUGH CONDUIT RUNS. CAPACITY 8(4 IN, 4 OUT) NO. 12 AWG CONDUCTORS,
RATED FOR 90°C.
5. UTILIZES HIGH-BRIGHTNESS LEDS MOUNTED TO A METAL CORE CIRCUIT BOARD, ENSURING
COOL-RUNNING OPERATION, CRI>80.
6. HIGH-EFFICIENCY, INTEGRAL ELECTRONIC LED DRIVER. PROVIDE DIMMABLE DRIVER WHERE
SHOWN CONTROLLED BY DIMMABLE SWITCH.
7. CERTIFICATION: UL LISTED AND DAMP LOCATION AND TESTED IN ACCORDANCE WITH IESNA
LM-79 AND LM-80 STANDARDS.
TYPE LUMENS LAMP TYPE INPUT WATTS VOLTAGE MOUNTING
RECESSED, CEILING120254000K LED2000
6"7-5/8"
MOUNTINGVOLTSINPUT WATTSLAMP TYPETYPE LUMENS
INDICATES CEILING MOUNT.
INDICATES WALL MOUNT 6" ABOVE DOOR TO BOTTOM OF FIXTURE.
MOUNTINGVOLTSINPUT WATTSLAMP TYPETYPE LUMENS
AI
NIG
RIVFOHTLAE
WNO
MM
OC
PR
OF
ESS I ONAL ENG
I NE
ER
DESIGNED
DRAWN
CHECKED
REV DATE DESCRIPTION
SHEET
SHEET NAME
APPROVED
DATE
COMM#
www.chpdesignstudio.org
PH. 540-382-2002 FAX 540-381-8270
CHRISTIANSBURG, VA 24073448 DEPOT STREET, N.E.
JAMES S. BEDOIS
Lic. No. 032929
#16244
E601
LIGHTING
DETAILS
KPM
MIN
JEB
JEB
3/15/2017
1603
KIN
GS
RID
GE
AP
AR
TM
EN
TS
CL
UB
HO
US
E
BU
ILD
ING
RIC
HM
ON
D,
VIR
GIN
IA
2/1/17
1 3/15/17 B.O. COMMENTS
1