  • 8/12/2019 Swing Fram

    1/4

    19 Swing Frame for protective cabinet

    Sd732-2e-19 Swing Frame for protective cabinet Page 1/ 4

    1 ApplicationFitting 19 rack mounted instruments into INTERTECcabinets and houses

    2 Description

    The integrated swing frame allows 19 racks to be usedwith all the advantages of INTERTEC protective cabinets,e.g.:

    Efficient insulation which prevents condensation andtemperature variation

    A high degree of dust and water protection for sensitiveinstruments is possible up to IP 65Double glazed windows in acrylic or safety glassinstalled at frame heightComplete system of accessories

    3 Advantages

    Exceptionally variable construction systemNearly all special requests can be incorporatedNo separate framework is needed, as it is integratedinto the existing mounting rail system.Corrosion-resistant 19 swing frame fabricated of brightStainless steelIntermediate sizes, special heights and widths are

    available

    4 Features

    19 construction system acc. IEC 60297 (DIN 41 494)Low distortion, welded constructionInfinitely variable in heightLocked by double spade bit style key and lock

    5 Options

    The tables on pages 2 to 4 show the most commonversions. Where possible the standard arrangement iscentred and an offset arrangement is shown in the planview next to it. The dimensions D, X and Y can beselected within certain limits, and the maximumavailable depth E is dependent upon them.Special designs available on requestNumber of units to your specification:up to 1000 mm a maximum of 16 units are possible,up to 1250 mm a maximum of 21 units are possible,up to 1500 mm a maximum of 26 units are possible,up to 1750 mm a maximum of 31 units are possible,up to 2000 mm a maximum of 39 units are possible.

    Side covers (shown in the diagram in maximum width,dimensions X and Y)Hinged left or right.Painted grey RAL 7032

    Also available as metrical construction system toIEC 60917

    BASIC CLASSIC

    Detail W

  • 8/12/2019 Swing Fram

    2/4

    19 Swing Frame for protective cabinet

    Sd732-2e-19 Swing Frame for protective cabinet Page 2/ 4

    6 Overview of ArrangementsI .

    Twin beam mounting II.

    Single beam moun ting III .

    Twin beam mounting IV.

    Single beam moun ting

    fixed behind door depth adjustable

    Installation weight 100kg,higher loads on requestLocking point top and/orbottom possible

    Installation weightin CLASSIC 50 kg,in BASIC 30 kg,higher loads on request.No restrictions from lowercross-beam

    Installation weight 100kg,higher loads on requestLocking point top and/orbottom possible

    Installation weightin CLASSIC 50 kg,in BASIC 30 kg,higher loads on request.No restrictions from lowercross-beam

    mounting in BASIC ... in CLASSIC mounting in BASIC ... in CLASSIC

    I. Twin beam mounting, fixed behind door

    600 800

    X+Y 160

    1000

    X+Y 360

    1250

    Supporting beam

    Door

    Wall panel

    Optionally(reduced installation depth)

  • 8/12/2019 Swing Fram

    3/4

    19 -Swing Frame for protective cabinet

    Sd732-2e-19 Swing Frame for protective cabinet Page 3/ 4

    II. Single beam mounting, fixed behind door

    600 800

    1000 1250

    III. Twin beam mounting, depth adjustable

    600 800

    X+Y 360

    1000

    X+Y 360

    1250Optionally

    (reduced installation depth)

    Optionally(reduced installation depth)

  • 8/12/2019 Swing Fram

    4/4

    19 -Swing Frame for protective cabinet

    Sd732-2e-19 Swing Frame for protective cabinet Page 4/ 4

    IV. Single beam mounting , depth adjustable

    600 800

    1000 1250

    7 Swivelling through 180

    e.g. CLASSIC ...080...

    BASIC and other dimensions on request.