USAWWW.FRIJADO.COM Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
INSTALLATION MANUAL
- NOTICE -This manual is prepared for the use of trained Service Technicians and should not be used by those not properly qualified. If you have atten-
ded a training for this product, you may be qualified to perform all the procedures in this manual.
This manual is not intended to be all encompassing. If you have not attended training for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the ne-cessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments
and skills should be performed by a trained technician.
Reproduction or other use of this Manual, without the express written consent of Fri-Jado, is prohibited.
TDR - ROTISSERIE OVEN MODELSTDW - WARMER MODELS
MODELS
TDR 5 MTDR 8 MTDW 5 MTDW 8 M
TDR 5 P eco
TDR 8 P eco
TDW 5 PTDW 8 P
Model TDR 5 M Model TDR 8 Peco
Page 2 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
TABLE OF CONTENTS
Page 3 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
VersionsVersion Issue date
dd/mm/yy
Remarks
03/2012 01/03/2012 First release.02/2014 01/02/2014 TDR P and TDRW added.
Page 4 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
Index .......................................................................................................................................................... 4
General technical data .............................................................................................................................. 5
Installation procedures ............................................................................................................................. 6Unpacking the unit ................................................................................................................................ 6Location .................................................................................................................................................. 7Electrical supply ..................................................................................................................................... 8Legs / Castors .......................................................................................................................................... 9Tethering of the unit ............................................................................................................................. 9Test run ................................................................................................................................................. 10Heat extraction of the rotisserie ......................................................................................................... 10Instructions for operators .................................................................................................................... 10
Placing and connecting of the models .................................................................................................. 12TDR 5 M Pass Through ........................................................................................................................ 12TDR 5 P Pass Through .......................................................................................................................... 13TDR 8 M Pass Through ......................................................................................................................... 14TDR 8 P Pass Through .......................................................................................................................... 15TDR 5 + 5 M Pass Through ................................................................................................................... 16TDR 5 + 5 P Pass Through .................................................................................................................... 17TDR 8 + 8 M Pass Through ................................................................................................................... 18TDR 8 + 8 P Pass Through .................................................................................................................... 19TDRW 5 M Pass Through ..................................................................................................................... 20TDRW 5 P Pass Through ....................................................................................................................... 21TDRW 8 M Pass Through ..................................................................................................................... 22TDRW 8 P Pass Through ....................................................................................................................... 23TDR 5 M and TDR 5 P Pass Through on base ...................................................................................... 24TDR 8 M and TDR 8 P Pass Through on base ...................................................................................... 25TDW 5 M Pass Through ....................................................................................................................... 26TDW 5 P Pass Through ......................................................................................................................... 27TDW 8 M Pass Through ....................................................................................................................... 28TDW 8 P Pass Through ......................................................................................................................... 29
INDEX
Page 5 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
GENERAL TECHNICAL DATA
GENERAL TECHNICAL DATA
This manual covers the TDR series rotisserie ovens and the TDW series warmers. Ovens and
warming cabinets come in two sizes. Ovens and warmers will also be delivered in stacked
versions.
• TDR5–Ovenwith5spits(15to20chickens)or5baskets(15chickens).
• TDR8-Ovenwith8spits(28to35chickens)or7baskets(28chickens).
• TDW5-Warmingcabinet25to30chickens.
• TDW8-Warmingcabinet35to40chickens.
Alloftheinformation,illustrationsandspecificationscontainedinthismanualarebasedon
thelatestproductinformationavailableatthetimeofprinting.
Type TDR 5 TDW 5 TDR 7 TDW 7
Power(W) 6600 2800 10500 3500
Fusesneededwithpowerconnec-tion208V,3~60Hz(3phaseswithoutzero)
3x20A _ 3x40A 3x20A
Fusesneededwithpowerconnec-tion208V,1N~60Hz(1phasewithzero)
_ 1x15A _ _
Standardplugfromfactory NEMA15-30P NEMA6-15P NEMA15-50P NEMA15-20P
Stackedcabinets:eachcabinetcomeswithseparatepowercord!!
Netweight(lbs) 287 220 408 331
Grossweight(lbs) 335 265 476 388
Height(inch) 353/4” 353/4” 413/4” 413/4”
Width(inch) 33” 33” 391/4” 391/4”
Depth(inch) 303/8” 303/8” 35” 35”
• Standardsetoftools.
• Metricwrenches,socketsandhexsocketkeywrenches.
• Multi-meterandACcurrentclampmeter.
• Temperaturetester.
• Insulationvaluetester(Megger).
• FieldServiceGroundingKit.
X
Y
GZ
G
X
Y
G
Z
XY
G
Z
Page 6 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
INSTALLATION PROCEDURES
INSTALLATION PROCEDURES
• Unpackingoftheunit.
• Removethepalletundertheunitwiththehelpofaforklift.
• Puttheunitonhislocation.
• Checkifthereisenoughfreespacearoundtheunit(seeinstallationdrawing).
• Checktheelectricalsupply.
• Tetheringoftheunit.
• TDR:Makeatestrunon482°F.
• TDW:Makeatestrunon210°F.
• Giveinstructionstotheoperator.
UNPACKING THE UNITImmediatelyafterunpackingtheoven,checkforpossibleshippingdamage.Iftheovenisfound
tobedamaged,savethepackagingmaterialandcontactthecarrierwithin15daysofdelivery.
Page 7 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
INSTALLATION PROCEDURES
LOCATION
Thestandardwaytoremovetherotisserieor
warmerfromapalletiswithaforklift.See
pictures.Opendoorandremovethedrawer.
Lifttheunitfrompalletandputtheunitin
itsplace.
Note: when lifting a stacked unit, always use
the drawer of the bottom unit.
Anotherpossibilityistodisassemblethepal-
let.ForthepalletoftheTDR8followthe
procedureonthephoto.
REMOVAL OF PALLET
Toavoidshort-circuiting,theunitsmaynotbe
usedoutdoors.Placingunderascreenisallo-
wed.
1 2 3
NL1
1 2 3
L2L1 L3
Page 8 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
INSTALLATION PROCEDURES
Priortoinstallation,testtheelectricalservicetoassurethatitcorrespondswiththespecificati-
onsonthemachinedataplatelocatedontherightsidepanelnearthecontrols.Theconnecting
cablefortheunitmustbeequippedwithanapprovedplugconnection.Ifuseistobemadeofa
permanentconnection,theconnectingcablemustbeconnectedtoamanualon/offswitchthat
isinstalledneartheunitinaclearvisiblemanner.
ELECTRICAL SUPPLY
IMPORTANT: Makesureyoulea-vesufficientspacearoundtherotisserieorwarmertoeasilyremoveorinserttherotor.Ifthebasehas(rotating)wheels,theflooronwhichitrestsmustbelevel.
Theovenmustbeinstalledonalevelsurface.Theinstallationlocationmustallowadequate
clearancesforservicingandproperoperation.
Theconnectingcablefortheunitmustbeequippedwithanapprovedplugconnection.Ifuse
istobemadeofapermanentconnection,theconnectingcablemustbeconnectedtoamanual
on/offswitchthatisinstalledneartheunitinaclearvisiblemanner.
For a single-phase 208 V ~ circuit with neutral, the unit must be connected according to the figure below.
For a 3-phase 208 V ~ circuit without neutral, the unit must be connected according to the figure below.
208 V, 1N ~ 50...60 Hz208 V, 3 ~ 50...60 Hz
Page 9 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
INSTALLATION PROCEDURES
Eachovenandwarmerisfurnishedon115/16”legs.Stackedmodelsarefurnishedwith2swivel
and2lockingswivelcastors.Acastor-equippedstandwithconvenientstoragedrawerisavaila-
ble;theovenismountedontopofthestand.
LEGS / CASTORS
TETHERING OF THE UNIT
(FormodelTDR5andTDR8unitswhenstackedorplacedonbasewithcastors)
Warning:Safetystandardsrequirethat,whenthisapplianceisproperlyconnectedtotheelec-
tricalpowersupplyusingflexibleconduit,adequatemeansbeprovidedtolimitmovementof
theappliancewithoutdependingonortransmittingstresstotheelectricalconduit.Thismeans
that,aspartoftheinstallation,thebaseorbottomunitofstackedmodelsmustbesecuredto
thebuildingstructure(typicallyeitherwallorfloor)tolimitthemovementoftheappliance
and,thus,helpingtopreventdamagetotheconduitduringcleaning,maintenanceandservice
operations.
Atetherbracket,asshownonthedrawingbelow,isprovidedwiththebaseorstackingkit.
Basedontheroutingoftheflexibleconduit,thebracketmustbeinstalledalongwiththecaster
toonecornerofthebaseusingthehardwareprovided.Theremainingopenholeinthecenter
ofthetetherbracketistobeusedtosecureoneendofthetether(locallysuppliedchain,cable,
etc.).Theotherendofthetetheristobesecuredtoananchoringpointinthebuildingstruc-
ture.
Note: Length of tether must be shorter than the flexible conduit to make sure that during appli-
ance movement, no stress is transmitted to the conduit.
Warning:Followinginstallation,checktoconfirmthat,whentheapplianceismovedtothe
limitsofthetetherineachdirection,nostressistransmittedtotheelectricalconduit.
Page 10 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
INSTALLATION PROCEDURES
Afterinstallationoftherotisserieorwarmer,theoperatoroftheunithastobeinstructed.
Theinstructionhastocoverthefollowingsubjects:
• Programmingandoptions.
• Workingoftheunit.
• Freespaceofunitforcoolingofdrivemotorandblowers.
• Reviewtheusermanual.
• Periodicalmaintenance:
o Cleaningoffanplateeverymonth.
• Howtoreactforinformationorservicecalls.
INSTRUCTIONS FOR OPERATORS
Theovenmustbeburnedintoreleaseanyodorsthatmightresultfromheatingthenewoven
surfaces.Operatetheovenatmaximumtemperaturesettingof482°Ffor30minutesandthe
warmeron210°F.Smokewithanunplaesantodourwillnormallybegivenoffduringthisburn-
inperiod.
TEST RUN
Althoughanextractionhoodisnotprescribed,itcouldbedesiredthatahoodisplacedover
therotisserie.TheTDR8producesabout350cfwatervapourandtheTDR5about200cf.When
placingtherotisserieunderanextractionhoodyouhavetoconsiderthefollowingguidelines:
-Theminimumcapacityoftheextractionhoodhastobe25000cf/h.
-Theextractionhoodhastoextendminimumby8”onallsidesoftherotisserie.
-Theextractionhoodhastohaveafreehight,abovetherotisserie,ofaminimumof12”.
-Therotisseriehastobeaccessibleforservicepurposes.
-Theextractionhoodhastobeslopingontheinsideforthecondensationtorundown.Around
thehoodtherehastobeagutterwithaconnectionforthewatertorundownadrain.
HEAT EXTRACTION OF THE ROTISSERIE
Page 11 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
Page 12 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
Description belonging to the lables on the drawingsLabel Description
1 Power cable, length 70” *
2 Exhaust opening
3 Space between a rotisserie and a wall or ceiling
4 Location for socket
*) length is measured from the point where the cables coms out of the unit
TDR 5 M PASS THROUGH
PLACING AND CONNECTING OF THE MODELS
Page 13 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 5 P PASS THROUGH
Page 14 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 8 M PASS THROUGH
Page 15 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 8 P PASS THROUGH
Page 16 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 5 + 5 M PASS THROUGH
Page 17 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 5 + 5 P PASS THROUGH
Page 18 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 8 + 8 M PASS THROUGH
Page 19 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 8 + 8 P PASS THROUGH
Page 20 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDRW 5 M PASS THROUGH
Page 21 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDRW 5 P PASS THROUGH
Page 22 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDRW 8 M PASS THROUGH
Page 23 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDRW 8 P PASS THROUGH
Page 24 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 5 M AND TDR 5 P PASS THROUGH ON BASE
Page 25 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDR 8 M AND TDR 8 P PASS THROUGH ON BASE
Page 26 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDW 5 M PASS THROUGH
Page 27 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDW 5 P PASS THROUGH
Page 28 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDW 8 M PASS THROUGH
Page 29 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
PLACING AND CONNECTING
TDW 8 P PASS THROUGH
Page 30 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
EMPTY PAGE
Page 31 Installation Manual TDR5/8 TDW 5/8 form 9123904 rev. 02/2014
EMPTY PAGE
For technical support call: 877 374-5236For parts call: 877 392-7851
Fri-Jado Inc. •1401 Davey Road • Sweet 100 • Woodridge, IL. 60517 • USA • tel. 630-630-7950 • fax 630-689-11424 • toll free 877-FRI-JADO • [email protected] • www.frijado.com