Wall fan-coil
•Range from 1,3 up to 2,5 kW
IndexIndexIndexIndex
– COMPARISON OLD NEW
– REATURES
– ACCESSORIES
– ELECTRONIC
– FUNCTIONS
– MASTER SLAVE
ComparisonComparison OLD - NEW OLD - NEWComparisonComparison OLD - NEW OLD - NEW IDROWALL IDROWALL4 models 3 models
Cooling capacity 1,02 ÷ 3,4 Cooling capacity 1,32 ÷ 2,48
FeaturesExternal valve in the frame
Work with water temperature till 55°C
Features2 Versions: - With inside valve
- Without valve
Work with water temperature till 70°C
DimensionsModels 10-20-30: 800x280x200 mmModels 40: 950x280x155 mm
DimensionsModels 22-33-44: 950x280x155 mm
AccessoriesRemote controlWall control panelWall recessed box with valve Wall recessed box with electronic 3 way valve
AccessoriesNew infrared remote controlNew wall control panelNew wall recessed box
Comparison OLD-NEWComparison OLD-NEWComparison OLD-NEWComparison OLD-NEW
Cooling power
1,02
1,69
2,41
3,4
1,32
1,95
2,48
0 1 2 3 4
10 / 22
20 / 33
30 / 44
40
Modello
kWf
IDROWALL old IDROWALL new 3 modelli
Acqua: 7/12°C
Aria: 27°C B.S. 19°C B.U.
Comparison OLD-NEWComparison OLD-NEWComparison OLD-NEWComparison OLD-NEWThermal powerThermal power
1,19
2,01
2,88
3,67
4,29
5,51
3,95
0 1 2 3 4 5 6
10 / 22
20 / 33
30 / 44
40
Modello
kW
Idrowall Old Idrowall New 3 modelli
Acqua: 70/60°C Aria: 20°C B.S. Acqua: 45°C / portata come in raffredd. Aria: 20°C B.S.
Features – Features – application field application field Features – Features – application field application field
IDROWALL MPCV
With 3 way ON/OFF electronic valve
for cooling and heating
IDROWALL MPCB
Without 3 way ON/OFF electronic
valve
only heating
t °C = inlet water temperature
U.R.% = ambient air relative humidity
features features – Version with electrovalve.– Version with electrovalve.features features – Version with electrovalve.– Version with electrovalve.
Air vent valve easely accessible
Water discharge valve on the coil
Supplyed loose accessoriesSupplyed loose accessoriesSupplyed loose accessoriesSupplyed loose accessories
KPCM – new control board with 11 keys
Accessori Accessori forniti separatamenteforniti separatamenteAccessori Accessori forniti separatamenteforniti separatamente
KTCM – LCD infra-red remote control
Supplyed loose accessories Supplyed loose accessories Supplyed loose accessories Supplyed loose accessories KVDF – wall recessed box for
the predisposition of the system side piping before the installation,completed of :
• Quick connection with ball valve
• Flexible connection piping
Electrical board Lay-Out Electrical board Lay-Out Electrical board Lay-Out Electrical board Lay-Out
•Flap
•ST1
•ST2
•Fan•Valve
•Riceiver
•Serial
•Hall
ClampsClampsClampsClamps
Idrowall 10 - 40
SCR = remote On-Off KPAN = control boardCKRP = aux contactRS 485 = serial connection VI = on – off valve
•KPCM
•Idrowall 22 - 44
•SCR = remote On-Off •KPCM = control board•C = aux contact•EIR = remote summer winter •SIC = remote safety•ECO = energy save
•Serial connection•Available soon
Dip-Swiches configurayionDip-Swiches configurayionDip-Swiches configurayionDip-Swiches configurayion
AllarmiAllarmiAllarmiAllarmi
FunzioniFunzioniFunzioniFunzioni
Regulation functions :
• Full auto• Cool • Heat• Fan• Dry
confort functions:
• Orienting/Swing (selection of the deflector position: swingin or fixed )
• Auto Fan / Fan speed (manual or authomatic ventilation)
• Sleep (night climatization function)• Too cool (summer block for temperature over 18°C
)• Hot start (winter consent of minimum temperature
[32; 36; 40 °C] )
FunctionsFunctionsFunctionsFunctions Advanced functions:
• Security control (il possible to subordinate the unit running to a remote control, clean contact. For example is possible to interrupt the running if a window is open with a control positioned in the window itself .)
• Economy (‘’save energy’’ function. You can enable it from a DIP switch positioned in the electrical board and activate it with a clean contact in alternative of the function ‘security control’)
• On/Off remote control (allows the switching on and off of the unit from a remote
switch ,clean contact)
• Lock function (conditioning bounded for Hotel rooms) [Full auto; Free vent ; auto mode if not SEI]
FunzioniFunzioniFunzioniFunzioni Le funzioni avanzate:
• Continuous ventilation (when the temperature set-point is reached the ventilation is forced to the lower speed)
• Timer (allows 1 daily ciclic programmed switching on/off of the unit)
• Probe in / Probe out (the ambient tmeperature can be felt by an inside probe (PROBE IN) or by a probe fixed in the unit (PROBE OUT)).
• Memory (after a black-out ,the unit will restart in the way that had immediatly before the supply black out).
FUNZIONIFUNZIONIFUNZIONIFUNZIONI
Periodical ventilation
– activ in cool/dry heat
– Not active with probe in
super-periodic ventilation at the start of the full-auto function (shorted after the remotation of the inside probe)
Is possible to read and change the parameters through the KPCM
The infrared remote control has to be configured at the first start up
Configurazione telecomandoConfigurazione telecomandoConfigurazione telecomandoConfigurazione telecomando
Page 9 of the user manual
Master - SlaveMaster - SlaveFunction Function
MASTER SLAVE SLAVE SLAVE
MAIN FEATURES
“broadcasting”logic: the units are all working in the same zone making exactly the same functions set in the MASTER
In the sign of continuity: easy electric connection between the control board of the single unit
More flexible: new for IDROWALL
Till a max N° of 5 slave units
CONTROLLO A FILO o TELECOMANDO
Master-Slave FunctionMaster-Slave Function Master-Slave FunctionMaster-Slave Function
Master-Slave functionMaster-Slave functionMaster-Slave functionMaster-Slave function Master-Slave net with remote control: connect the
electrical heater (rpower 1,2 Kohm 0,5W)
The electronic board self-configures itself as master for the presence of the panel or of the electrical heater in the first unit Con pannellino si può scegliere Probe in/out
Diagnostic on Slave only with the LED
Inlets Slave ECO, EIR, Lock Func., are disactivated
SCR Master: blocks all the chain
SCR Slave: Blocks only the specific unit
SIC:Blocks only the specific unit