Technical updateTechnical update

Service meeting

Codroipo 13/14-06-05

Page 2: Technical update Service meeting Codroipo 13/14-06-05

IDROWALL RangeIDROWALL RangeIDROWALL RangeIDROWALL Range

Wall fan-coil

•Range from 1,3 up to 2,5 kW

Page 3: Technical update Service meeting Codroipo 13/14-06-05

IndexIndexIndexIndex

– COMPARISON OLD NEW

– REATURES

– ACCESSORIES

– ELECTRONIC

– FUNCTIONS

– MASTER SLAVE

Page 4: Technical update Service meeting Codroipo 13/14-06-05

ComparisonComparison OLD - NEW OLD - NEWComparisonComparison OLD - NEW OLD - NEW IDROWALL IDROWALL4 models 3 models

Cooling capacity 1,02 ÷ 3,4 Cooling capacity 1,32 ÷ 2,48

FeaturesExternal valve in the frame

Work with water temperature till 55°C

Features2 Versions: - With inside valve

- Without valve

Work with water temperature till 70°C

DimensionsModels 10-20-30: 800x280x200 mmModels 40: 950x280x155 mm

DimensionsModels 22-33-44: 950x280x155 mm

AccessoriesRemote controlWall control panelWall recessed box with valve Wall recessed box with electronic 3 way valve

AccessoriesNew infrared remote controlNew wall control panelNew wall recessed box

Page 5: Technical update Service meeting Codroipo 13/14-06-05

Comparison OLD-NEWComparison OLD-NEWComparison OLD-NEWComparison OLD-NEW

Cooling power

1,02

1,69

2,41

3,4

1,32

1,95

2,48

0 1 2 3 4

10 / 22

20 / 33

30 / 44

40

Modello

kWf

IDROWALL old IDROWALL new 3 modelli

Acqua: 7/12°C

Aria: 27°C B.S. 19°C B.U.

Page 6: Technical update Service meeting Codroipo 13/14-06-05

Comparison OLD-NEWComparison OLD-NEWComparison OLD-NEWComparison OLD-NEWThermal powerThermal power

1,19

2,01

2,88

3,67

4,29

5,51

3,95

0 1 2 3 4 5 6

10 / 22

20 / 33

30 / 44

40

Modello

kW

Idrowall Old Idrowall New 3 modelli

Acqua: 70/60°C Aria: 20°C B.S. Acqua: 45°C / portata come in raffredd. Aria: 20°C B.S.

Page 7: Technical update Service meeting Codroipo 13/14-06-05

Features – Features – application field application field Features – Features – application field application field

IDROWALL MPCV

With 3 way ON/OFF electronic valve

for cooling and heating

IDROWALL MPCB

Without 3 way ON/OFF electronic

valve

only heating

t °C = inlet water temperature

U.R.% = ambient air relative humidity

Page 8: Technical update Service meeting Codroipo 13/14-06-05

features features – Version with electrovalve.– Version with electrovalve.features features – Version with electrovalve.– Version with electrovalve.

Air vent valve easely accessible

Water discharge valve on the coil

Page 9: Technical update Service meeting Codroipo 13/14-06-05

Supplyed loose accessoriesSupplyed loose accessoriesSupplyed loose accessoriesSupplyed loose accessories

KPCM – new control board with 11 keys

Page 10: Technical update Service meeting Codroipo 13/14-06-05

Accessori Accessori forniti separatamenteforniti separatamenteAccessori Accessori forniti separatamenteforniti separatamente

KTCM – LCD infra-red remote control

Page 11: Technical update Service meeting Codroipo 13/14-06-05

Supplyed loose accessories Supplyed loose accessories Supplyed loose accessories Supplyed loose accessories KVDF – wall recessed box for

the predisposition of the system side piping before the installation,completed of :

• Quick connection with ball valve

• Flexible connection piping

Page 12: Technical update Service meeting Codroipo 13/14-06-05

Electrical board Lay-Out Electrical board Lay-Out Electrical board Lay-Out Electrical board Lay-Out

•Flap

•ST1

•ST2

•Fan•Valve

•Riceiver

•Serial

•Hall

Page 13: Technical update Service meeting Codroipo 13/14-06-05

ClampsClampsClampsClamps

Idrowall 10 - 40

SCR = remote On-Off KPAN = control boardCKRP = aux contactRS 485 = serial connection VI = on – off valve

•KPCM

•Idrowall 22 - 44

•SCR = remote On-Off •KPCM = control board•C = aux contact•EIR = remote summer winter •SIC = remote safety•ECO = energy save

•Serial connection•Available soon

Page 14: Technical update Service meeting Codroipo 13/14-06-05

Dip-Swiches configurayionDip-Swiches configurayionDip-Swiches configurayionDip-Swiches configurayion

Page 15: Technical update Service meeting Codroipo 13/14-06-05

AllarmiAllarmiAllarmiAllarmi

Page 16: Technical update Service meeting Codroipo 13/14-06-05

FunzioniFunzioniFunzioniFunzioni

Regulation functions :

• Full auto• Cool • Heat• Fan• Dry

     confort functions:

• Orienting/Swing (selection of the deflector position: swingin or fixed )

• Auto Fan / Fan speed (manual or authomatic ventilation)

• Sleep (night climatization function)• Too cool (summer block for temperature over 18°C

)• Hot start (winter consent of minimum temperature

[32; 36; 40 °C] )

  

Page 17: Technical update Service meeting Codroipo 13/14-06-05

FunctionsFunctionsFunctionsFunctions Advanced functions:

•  Security control (il possible to subordinate the unit running to a remote control, clean contact. For example is possible to interrupt the running if a window is open with a control positioned in the window itself .)

• Economy (‘’save energy’’ function. You can enable it from a DIP switch positioned in the electrical board and activate it with a clean contact in alternative of the function ‘security control’)

• On/Off remote control (allows the switching on and off of the unit from a remote

switch ,clean contact)  

• Lock function (conditioning bounded for Hotel rooms) [Full auto; Free vent ; auto mode if not SEI]

Page 18: Technical update Service meeting Codroipo 13/14-06-05

FunzioniFunzioniFunzioniFunzioni    Le funzioni avanzate:

•  Continuous ventilation (when the temperature set-point is reached the ventilation is forced to the lower speed)

• Timer (allows 1 daily ciclic programmed switching on/off of the unit)

• Probe in / Probe out (the ambient tmeperature can be felt by an inside probe (PROBE IN) or by a probe fixed in the unit (PROBE OUT)).

• Memory (after a black-out ,the unit will restart in the way that had immediatly before the supply black out).

Page 19: Technical update Service meeting Codroipo 13/14-06-05

FUNZIONIFUNZIONIFUNZIONIFUNZIONI

Periodical ventilation

– activ in cool/dry heat

– Not active with probe in

super-periodic ventilation at the start of the full-auto function (shorted after the remotation of the inside probe)

Is possible to read and change the parameters through the KPCM

The infrared remote control has to be configured at the first start up

Page 20: Technical update Service meeting Codroipo 13/14-06-05

Configurazione telecomandoConfigurazione telecomandoConfigurazione telecomandoConfigurazione telecomando

Page 9 of the user manual

Page 21: Technical update Service meeting Codroipo 13/14-06-05

Master - SlaveMaster - SlaveFunction Function

MASTER SLAVE SLAVE SLAVE

MAIN FEATURES

“broadcasting”logic: the units are all working in the same zone making exactly the same functions set in the MASTER

In the sign of continuity: easy electric connection between the control board of the single unit

More flexible: new for IDROWALL

Till a max N° of 5 slave units

CONTROLLO A FILO o TELECOMANDO

Page 22: Technical update Service meeting Codroipo 13/14-06-05

Master-Slave FunctionMaster-Slave Function Master-Slave FunctionMaster-Slave Function

Page 23: Technical update Service meeting Codroipo 13/14-06-05

Master-Slave functionMaster-Slave functionMaster-Slave functionMaster-Slave function Master-Slave net with remote control: connect the

electrical heater (rpower 1,2 Kohm 0,5W)

The electronic board self-configures itself as master for the presence of the panel or of the electrical heater in the first unit Con pannellino si può scegliere Probe in/out

Diagnostic on Slave only with the LED

Inlets Slave ECO, EIR, Lock Func., are disactivated

SCR Master: blocks all the chain

SCR Slave: Blocks only the specific unit

SIC:Blocks only the specific unit