39
608 South St. South Kirkland, WA 98033 www.faira.com [email protected] 1 (800) 571-FAIR FAIRA TRANSPARENCY REPORT 735 White St, Walla Walla, WA 99362 October 16, 2019 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. Please note that not all sellers opt into the inspection portion of our reports. You may view more detailed information for this home and can make an offer at All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

608 South St. South Kirkland, WA 98033

www.faira.com [email protected] 1 (800) 571-FAIR

FAIRA TRANSPARENCY REPORT

735 White St, Walla Walla, WA 99362

October 16, 2019

Thank you for your interest in this Faira Certified home.

We have coordinated the efforts of certified and licensed inspection and title professionals to createthe Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolioof information that is prepared on behalf of buyers in preparation for making an informed offer on theproperty.

Please note that not all sellers opt into the inspection portion of our reports.

You may view more detailed information for this home and can make an offer at

All of the information in the Faira Transparency Reports was gathered and compiled without any biasor influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s)ordered the same professionals to perform the evaluations on the same date. Nevertheless, Fairatakes no obligation of the reports being complete or accurate. The buyers are recommended toconduct their own due-diligence to their satisfaction.

Please contact us if you have any questions or would like more information.

We're happy you've chosen a Faira Certified home and look forward to the opportunity of working withyou!

The Faira Team

Page 2: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Inspection ReportPrepared for: William Sanguine

Property Address:735 White Street

Walla Walla WA 99362

Blue Valley Home Inspection

Trent Tarter3963 Old Milton Hwy.

Walla Walla, WA 99362Phone: (509) [email protected]

Washington State Licensed Home Inspector #470

Page 3: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

WSDA Structural Pest Inspector #71761Oregon State Licensed Home Inspector #213631

Blue Valley Home Inspection Sanguine

735 White Street Page 2 of 38

Page 4: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

INVOICE

3963 Old Milton Hwy.Walla Walla, WA 99362

[email protected]

Washington State Licensed Home Inspector#470Oregon State Licensed Home Inspector#213631WSDA Structural Pest Inspector #71761

Inspected By: Trent Tarter

Inspection Date: 10/15/2019Report ID: ICN: 10108BJ021

Customer Info: Inspection Property:

William Sanguine735 White StreetWalla Walla WA 99362

Customer's Real Estate Professional:Levi OstromFaira

735 White StreetWalla Walla WA 99362

Inspection Fee:

Service Price Amount Sub-TotalHeated Sq Ft 1,001 - 2,000 450.00 1 450.00

Total Price $450.00

Payment Method:Payment Status: Pending (Real Estate Company Paying For Inspection)Note: Thanks for choosing Blue Valley Home Inspection

Blue Valley Home Inspection Sanguine

735 White Street Page 3 of 38

Page 5: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Blue Valley Home Inspection Sanguine

735 White Street Page 4 of 38

Page 6: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Table of ContentsCover Page.......................................................................................... 1

Invoice ................................................................................................. 3

Table of Contents................................................................................. 5

Intro Page ............................................................................................ 6

1 EXTERIOR ....................................................................................... 8

2 ROOFING ....................................................................................... 10

3 ATTIC AND ROOF STRUCTURE .................................................. 12

4 ELECTRICAL SYSTEM.................................................................. 13

5 HEATING / AIR CONDITIONING ................................................... 14

6 PLUMBING / FUEL SYSTEMS....................................................... 16

7 KITCHEN COMPONENTS AND BUILT IN APPLIANCES ............. 19

8 BATHROOMS................................................................................. 20

9 INTERIORS .................................................................................... 22

10 FOUNDATIONS, BASEMENTS, AND CRAWLSPACES.............. 23

11 DETACHED GARAGE .................................................................. 26

General Summary.............................................................................. 29

Structural Pest Inspection Summary ................................................. 34

Back Page ......................................................................................... 36

Agreement ......................................................................................... 37

Blue Valley Home Inspection Sanguine

735 White Street Page 5 of 38

Page 7: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Date: 10/15/2019 Time: Report ID: ICN: 10108BJ021Property:735 White StreetWalla Walla WA 99362

Customer:William Sanguine

Real Estate Professional:Levi OstromFaira

"THIS REPORT IS INTENDED ONLY FOR THE USE OF THE PERSON PURCHASING THE HOME/BUILDING INSPECTION SERVICES. NO OTHER PERSON, INCLUDING A PURCHASER OF THEINSPECTED PROPERTY WHO DID NOT PURCHASE THE HOME/BUILDING INSPECTIONSERVICES, MAY RELY UPON ANY REPRESENTATION MADE IN THE REPORT".

Inspector agrees to perform the inspection in accordance with the standards of practiceestablished by the state in which the home inspection takes place (Washington or Oregon).These standards of practice may be found at the following links:

Washington State Standards of PracticeOregon State Standards of Practice

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should beconsidered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a secondopinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair orreplacement of item, component or unit should be considered before you purchase the property.

Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to befunctioning as intended allowing for normal wear and tear.

Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it wasfunctioning as intended and will state a reason for not inspecting.

Not Present (NP) = This item, component or unit is not in this home or building.

(Summary items) = The item, component or unit is not functioning as intended, or needs further inspection by a qualifiedcontractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.

Standards of Practice:Washington State Standards of Practice

In Attendance:Client(s)

Type of building:Single Family (1 story with full basement)

Home occupied:No

Approximate age of building:Built in 1955

Age souce:Online sources

Temperature:54 degrees

Weather:Clear

Ground/Soil surface condition:Dry

Blue Valley Home Inspection Sanguine

735 White Street Page 6 of 38

Page 8: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Rain in the last three days:No

Home is considered to be facing:East

Blue Valley Home Inspection Sanguine

735 White Street Page 7 of 38

Page 9: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

1. EXTERIOR

Styles & Materials

SIDING MATERIAL:Vinyl

EXTERIOR ENTRY DOORS:Fiberglass

DRIVEWAY:Concrete

WINDOW TYPES (primary locations):Vinyl (double pane)Wood framed (single pane)

Items

1.0 EXTERIOR SIDING AND TRIMInspected

1.1 EAVES, SOFFITS AND FASCIASInspected

1.2 DOORS (Exterior)Comments

Rear entry door has a deadbolt installed with no handle (a key is required to open from both sides). Thiscan be a safety hazard in the event of a fire if the key is not available. I recommend replacing with a deadboltthat has a handle on the interior side.

Blue Valley Home Inspection Sanguine

735 White Street Page 8 of 38

Page 10: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

1.3 WINDOWSInspected

1.4 DRIVEWAYComments

1.5 SIDEWALKS AND PATIOSInspected

1.6 STAIRS, HANDRAILS, GUARDRAILSComments

Exterior trim is missing at basement window.

(1) Cracks and deterioration in driveway.

(2) Driveway slopes toward front of garage. This may cause water to accumulate and/or enter below doorduring times of heavy rain fall.

Blue Valley Home Inspection Sanguine

735 White Street Page 9 of 38

Page 11: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

1.7 GRADING AND DRAINAGEInspected

1.8 VEGETATION AND LANDSCAPING (Report vegetation concerns that may effect the structure.)Inspected

2. ROOFINGStyles & Materials

ROOF COVERING:3-Tab fiberglass

ROOF AGE (estimated):12-15 years

ROOF-TYPE:GableHip

NUMBER OF ROOF LAYERS:One

VIEWED ROOF COVERING FROM:Walked roof

CHIMNEY (exterior):Concrete BlockMetal Flue Pipe

GUTTER & DOWNSPOUT MATERIAL:Metal/Aluminum

Items

2.0 ROOFING MATERIALInspected

No handrail is installed at front entry stairs. Consider installing a handrail for safety.

Blue Valley Home Inspection Sanguine

735 White Street Page 10 of 38

Page 12: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

2.1 EXPOSED FLASHING/CAULKINGInspected

2.2 CHIMNEYS AND FLUE PIPESComments

(1) The roof is in satisfactory condition. Shingles are starting to show normal age and wear.

(2) Moss is growing on the roof. Moss should be removed, also efforts should be taken to kill the mossduring its growing season (wet months). Typically zinc-based chemicals are used for this, and must be appliedperiodically.

(1) Excessive tar sealant has been applied at chimney flashing, evidence of past leaking in attic. Irecommend having a roofing contractor evaluate, repair/replace flashing as needed.

Blue Valley Home Inspection Sanguine

735 White Street Page 11 of 38

Page 13: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

2.3 VENTS AND FLASHINGS (for ventilation systems and roof penetrations)Comments

2.4 GUTTERS AND DOWNSPOUTSComments

3. ATTIC AND ROOF STRUCTUREStyles & Materials

METHOD USED TO OBSERVE ATTIC:From top of access hatch

CEILING STRUCTURE:Rafters

ROOF STRUCTURE:Rafters

ATTIC INSULATION:Blown Cellulose

INSULATION DEPTH:14+ inches

ROOF VENTILATION:Roof ventsSoffit Vents

(2) Minor cracks/openings at top of chimney cap should be sealed with masonry caulk or suitable crackfiller.

Rubber boots are cracked/deteriorated at plumbing vent flashings. Repair/replace vent flashings asneeded.

Gutters are full of leaves and debris. I recommend cleaning and maintaining on a regular basis.

Blue Valley Home Inspection Sanguine

735 White Street Page 12 of 38

Page 14: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

ROOF SHEATHING:Soild wood planks

ATTIC ACCESS LOCATION:Bedroom closet

Items

3.0 ATTIC AND ROOF STRUCTUREComments

3.1 INSULATION IN ATTICInspected

3.2 ATTIC VENTILATIONInspected

4. ELECTRICAL SYSTEMStyles & Materials

ELECTRIC SERVICE CONDUCTORS:Overhead service

MAIN SERVICE PANEL CAPACITY:200 AMP

LOCATION OF MAIN ELECTRICALPANEL:

Exterior

LOCATION OF SUB PANELS:Basement

PANEL TYPE:Circuit breakers

ELECTRIC PANEL MANUFACTURE:SQUARE D

BRANCH CIRCUIT WIRE 15 AND 20AMP:

Copper

WIRING METHODS:Non-metallic sheathed cable (Romex)Early cloth sheathed Romex

(ungrounded)

GROUNDING METHOD (Main ServicePanel):

Ground Rod

GFCI PROTECTED RECEPTACLESINSTALLED:

One of the roof rafters is lacking support, at side of chimney. I recommend installing additional support asneeded.

(1) Attic has been well insulated. However, insulation in low and displaced in areas near access hatch. Irecommend redistributing insulation, fill in low areas.

(2) I recommend installing insulation above the attic access hatch to prevent heat loss.

Blue Valley Home Inspection Sanguine

735 White Street Page 13 of 38

Page 15: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

KitchenBathroomsExterior

Items

4.0 SERVICE ENTRANCE CONDUCTORSInspected

4.1 MAIN ELECTRICAL PANELS, CIRCUIT BREAKERS, FUSES, AND GROUNDINGInspected

4.2 BRANCH CIRCUIT WIRINGInspected

4.3 RECEPTACLES, SWITCHES, FIXTURES AND JUNCTION BOXESComments

4.4 GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTED RECEPTACLESInspected

4.5 SMOKE DETECTORSComments

4.6 CARBON MONOXIDE DETECTORSComments

5. HEATING / AIR CONDITIONINGStyles & Materials

FURNACE/AIR HANDLER LOCATION:BASEMENT

HEAT TYPE:Gas furnace (forced air)

ENERGY SOURCE:Natural gas

(1) Some of the homes receptacles are ungrounded (both 2-prong and 3-prong). This is most likely due toolder sections of wiring having only two wires and not a third ground wire. Electrical codes require ungroundedreceptacles to either be the 2-prong type or allow them to be converted to 3-prong receptacles if they are GFCIprotected. Be aware that any appliance with a 3-prong plug relies on grounding.

(2) One of the basement bedrooms has no electric receptacles installed. The other basement bedroomhas only one receptacle installed.

(3) Majority of basement rooms has older style pull chain light fixtures. No wall switches are installed.

(4) Receptacle(s) are missing cover plates at one or more locations. Install cover plates where missing.

Smoke alarms are not installed in bedrooms. Each bedroom should have an operational smoke alarminstalled.

A carbon monoxide detector should be installed at main floor hallway leading to bedrooms.

Blue Valley Home Inspection Sanguine

735 White Street Page 14 of 38

Page 16: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

HEAT SYSTEM BRAND:CARRIER

HEATING SYSTEM AGE (approximate):Manufactured 1994

COOLING EQUIPMENT TYPE:Split system (standard)

AIR CONDITIONING AGE (approximate):AC condenser manufactured 2005

CENTRAL AIR MANUFACTURE:AMERICAN STANDARD

DUCTWORK:Sheet metal and metal ducts

FILTER TYPE:Disposable

FILTER LOCATION:Side of furance

TYPES OF FIREPLACES ANDWOODSTOVES:

Wood burning fireplace(s)

Items

5.0 HEATING SYSTEMComments

5.1 THERMOSTATS AND OPERATING CONTROLSInspected

5.2 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters,registers, radiators, fan coil units and convectors)Inspected

5.3 PRESENCE OF INSTALLED HEAT SOURCE IN MAIN LIVING AREAS AND BEDROOMSInspected

5.4 CHIMNEYS, FLUES AND VENTS (for gas water heaters or heat systems)Inspected

5.5 COOLING AND AIR HANDLER EQUIPMENTNot Inspected

The gas furnace is 25 years old, it operated when tested. Rust, corrosion, and moisture was found insidefurnace cabinet. This is from flue condensation leaking. I recommend having a qualified HVAC contactorfurther evaluate, repair or replace furnace as needed.

Blue Valley Home Inspection Sanguine

735 White Street Page 15 of 38

Page 17: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

5.6 SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove)Inspected

6. PLUMBING / FUEL SYSTEMSStyles & Materials

WATER SOURCE:City

PLUMBING WATER SUPPLY (into home):Galvanized steel

PLUMBING WATER DISTRIBUTION(inside home):

Galvanized steel (old)Copper

PLUMBING WASTE:Cast iron (old)Galvanized pipe (old)ABS/Black Plastic (small amount)

WATER HEATER AGE:Manufactured in 1994 (gas unit)Manufactured in 1990 (electric unit)Serial Number# : Electric unit 1990

WATER HEATER POWER SOURCE:ElectricGas

WATER HEATER CAPACITY:(2) 50 Gallon

WATER TEMPERATURE:120+ degrees

MANUFACTURE:CRAFTMASTERRHEEM

EARTHQUAKE STRAPPINGINSTALLLED ON WATER HEATER:

NO

EXPANSION TANK INSTALLED ONWATER HEATER:

NO

LOCATION OF DRYER VENTTERMINATION:

Exterior wall

Items

6.0 PLUMBING WATER SUPPLY PIPESInspected

6.1 PLUMBING DRAIN, WASTE AND VENT SYSTEMSComments

The A/C could not be tested for proper operation due to the outside air temperature below 60 degrees.We did not inspect this system.

Fireplace damper opens and closes properly. A fireplace screens should be installed.

Some of the water supply pipes in this home are made of galvanized steel. Be aware that these pipes areolder. Pipes were tested by running multiple fixtures at the same time. Pressure and flow was adequate.

Blue Valley Home Inspection Sanguine

735 White Street Page 16 of 38

Page 18: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

6.2 WATER HEATERSComments

(1) Based on age of home, I recommend having a plumber perform a sewer scope inspection of mainsewer line. According to home owner the main sewer line has been replaced.

(2) Cast iron drain pipe is basement has rust and signs of past leaking. No leaks were detected at time ofinspection. Old cast iron pipe will eventually need replaced.

(1) Both water heaters are past normal life expectancy. They were working at time of inspection, I amunable to determine life remaining.

Blue Valley Home Inspection Sanguine

735 White Street Page 17 of 38

Page 19: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

6.3 MAIN WATER SHUT-OFF DEVICE (Describe location)Inspected

6.4 EXTERIOR FAUCETS AND HYDRANTSComments

(2) The water heaters do not have earthquake straps installed. Standard building practices requireearthquake straps to be installed to properly secure water heaters.

(3) The water heater does not have a "Thermal Expansion tank" installed. Thermal expansion tanks arerequired when the incoming main water supply has a check flow valve for backflow prevention. If the waterheater TPR valve begins to drip or leak, then a thermal expansion tank may be needed.

(4) Substandard wiring was found for the water heater's power supply. Exposed non-metallic sheathed(Romex) wiring is used. Typically, flexible conduit with bushings is used in this application.

(5) No drain line is installed for the temperature-pressure relief valve. A drain line should be installedextending to 6 inches from the floor.

The main water shut-off valve is located in the basement.

Blue Valley Home Inspection Sanguine

735 White Street Page 18 of 38

Page 20: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

6.5 GAS SUPPLY AND DISTRIBUTION SYSTEMS (gas meter, piping, venting, supports, leaks)Inspected

6.6 MAIN FUEL SHUT OFF (Describe Location)Inspected

6.7 LAUNDRY/UTILITY SINKSComments

6.8 IRRIGATION SYSTEMNot Inspected

7. KITCHEN COMPONENTS AND BUILT IN APPLIANCESItems

7.0 FLOORSInspected

7.1 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETSInspected

7.2 SINKS AND RELATED PLUMBINGInspected

7.3 DISHWASHERNot Present

7.4 RANGES/OVENS/COOKTOPSInspected

Exterior faucets are not the frost free type and will need winterized during freezing temperatures.

The main fuel shut-off is at the gas meter outside.

Leaks were found at water supply connections below laundry sink. Low water pressure/flow detected athot side.

It's outside the scope of this inspection to evaluate underground sprinkler and irrigation systems.

Blue Valley Home Inspection Sanguine

735 White Street Page 19 of 38

Page 21: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

7.5 RANGE HOOD/EXHAUST FANComments

7.6 REFRIGERATORNot Inspected

8. BATHROOMSItems

8.0 CEILINGSInspected

8.1 WALLSInspected

8.2 FLOORSInspected

8.3 COUNTERS AND CABINETSInspected

8.4 TOILETSInspected

8.5 TUBS AND SHOWERSInspected

8.6 SINKS AND RELATED PLUMBINGComments

Kitchen exhaust fan vents into the attic. I recommend venting properly to exterior so that all moisture isvented outdoors.

The refrigerator was not inspected. It's beyond the scope of this inspection to evaluate refrigeration units.

Basement bathroom: Sink leaks at wall drain connection below cabinet. Repair as needed.

Blue Valley Home Inspection Sanguine

735 White Street Page 20 of 38

Page 22: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

8.7 EXHAUST FANSComments

8.8 JETTED TUBInspected

(1) Main floor bathroom exhaust fan vents into the attic. This is a conducive condition for wood destroyingorganisms due to increased moisture levels in the attic. Exhaust fans should be vented properly to exterior, sothat all moisture is vented outdoors.

(2) Basement bathroom exhaust fan is not venting properly, no airflow was detected at exterior vent cap.Repairs should be made so that all moisture is vented outdoors.

(1) Jetted tub was filled and operated. Electrical supply has required ground fault circuit interrupter (GFCI)protection.

(2) The jetted tub needs cleaned and flushed, debris in water was found after operating tub. Jetted tubsrequire periodic cleaning and sanitizing. Jetted tub cleaners, chlorine bleach, or white vinegar may be used toclean and flush jets.

Blue Valley Home Inspection Sanguine

735 White Street Page 21 of 38

Page 23: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

9. INTERIORSStyles & Materials

CEILING MATERIALS:DrywallPlaster

WALL MATERIAL:DrywallPlaster

FLOOR COVERINGS:CarpetTileHardwood T&G

Items

9.0 WALLSInspected

9.1 CEILINGSInspected

9.2 FLOORSInspected

9.3 STEPS, STAIRWAYS, BALCONIES AND RAILINGSComments

(1) Minor stress cracks in wall at rear main floor bedroom.

(2) Bedroom wall has been roughly patched in area.

Blue Valley Home Inspection Sanguine

735 White Street Page 22 of 38

Page 24: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

9.4 DOORS (REPRESENTATIVE NUMBER)Comments

9.5 WINDOWS (REPRESENTATIVE NUMBER)Comments

10. FOUNDATIONS, BASEMENTS, AND CRAWLSPACESStyles & Materials

No guardrails are installed at open side of stairs. Standard building practices require guardrails to beinstalled at drop-offs higher than 30 inches. Note that this is a safety concern for small children.

No doors are installed at basement rooms.

(1) Basement bedroom windows have inadequate egress in the event of a fire due to the opening sizebeing too small. Bedroom windows should be easy to open, stay open by themselves, and have:

• A minimum width of opening of 20 inches• A minimum height of opening of 24 inches• A minimum net clear opening of 5.7 square feet

(2) One of the main floor windows has water stains at window sill. Area was dry at time of inspection.

Blue Valley Home Inspection Sanguine

735 White Street Page 23 of 38

Page 25: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

FOUNDATION:Basement (concrete block)

FLOOR STRUCTURE:Wood joistsConcrete slab (basement floor)

COLUMNS OR PIERS:Supporting walls

Items

10.0 FOUNDATIONS, BASEMENTS, AND CRAWLSPACES (Report signs of harmful water intrusion or moisturerelated concerns)Comments

(1) Basement has signs of past moisture penetration at north side. Old water stains found at lower edgesof walls, wood paneling is damaged. Basement areas were dry at time of inspection.

Blue Valley Home Inspection Sanguine

735 White Street Page 24 of 38

Page 26: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

10.1 FLOORS (Structural)Inspected

10.2 WOOD DESTROYING INSECTS AND ORGANISMSInspected

10.3 LIMITATIONS AND INACCESSIBLE AREASNot Inspected

(2) White efflorescence (powder substance) was found in areas on basement walls (north side). This iscommonly found in older homes. Efflorescence occurs as moisture passes through concrete leaving mineraland salt deposits behind.

There was no visible evidence of Wood Destroying Insects, past infestation and/or damage at this structureduring this inspection.

There's a small inaccessible crawlspace area below front living room. This area extends past basement. Acrawlspace vent is installed at exterior. Inaccessible crawlspace areas are excluded from the inspection.

Blue Valley Home Inspection Sanguine

735 White Street Page 25 of 38

Page 27: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

11. DETACHED GARAGE

Styles & Materials

SIDING MATERIAL:Vinyl

ROOF COVERING:3-Tab fiberglass

ROOF AGE (estimated):12-15 years

FOUNDATION:Basement (concrete block)

GARAGE DOOR TYPE:One manual

GARAGE DOOR MATERIAL:Metal

Items

11.0 EXTERIOR/STRUCTUREInspected

11.1 ROOFING MATERIAL AND ROOF STRUCTUREInspected

11.2 WALLS AND CEILINGSInspected

11.3 FLOORComments

11.4 ENTRY DOORComments

Garage roof is in satisfactory condition. Shingles are starting to show normal age and wear.

Cracks and settlement in concrete slab floor.

Blue Valley Home Inspection Sanguine

735 White Street Page 26 of 38

Page 28: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

11.5 GARAGE DOOR (S)Inspected

11.6 ELECTRIC DOOR OPENERSInspected

11.7 ELECTRICAL PANELInspected

11.8 WIRING, LIGHTS AND RECPTACLESComments

11.9 GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTED RECEPTACLESComments

Side entry door was locked and was not opened. Door frame is damaged near latch.

The sensors are in place for garage door(s) and will reverse the door.

(1) Substandard wiring, exposed Romex wiring is routed on garage walls. Conduit or armored cableshould be used in this type of application.

(2) Receptacle(s) are missing cover plates at one or more locations. Install cover plates where missing.

Blue Valley Home Inspection Sanguine

735 White Street Page 27 of 38

Page 29: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Garage receptacles are not GFCI protected. For improved safety, I recommend installing GFCI protectionat all garage receptacles.

Blue Valley Home Inspection Sanguine

735 White Street Page 28 of 38

Page 30: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

General Summary

3963 Old Milton Hwy.Walla Walla, WA 99362Phone: (509) [email protected]

Washington State Licensed Home Inspector #470 WSDA Structural Pest Inspector #71761Oregon State Licensed Home Inspector #213631

CustomerWilliam Sanguine

Address735 White Street

Walla Walla WA 99362

The following list of items and/or discoveries describe defects, improper conditions, items in need of servicing, maintenance,repair or replacement. Please refer to each individual comment for descriptions and recommendations. In general, cosmeticissues are not noted. The inspector attempts to note items and/or systems that are defective, not working properly,conditions that are detrimental to the structure and/or improper conditions that pose safety hazards. Advise contactinglicensed contractors, professionals and/or qualified experts to provide any needed remedial work beyond your ability andexpertise.

1. EXTERIOR

1.2 DOORS (Exterior)CommentsRear entry door has a deadbolt installed with no handle (a key is required to open from both sides). This can be asafety hazard in the event of a fire if the key is not available. I recommend replacing with a deadbolt that has ahandle on the interior side.

1.4 DRIVEWAYComments(1) Cracks and deterioration in driveway.(2) Driveway slopes toward front of garage. This may cause water to accumulate and/or enter below door duringtimes of heavy rain fall.

Blue Valley Home Inspection Sanguine

735 White Street Page 29 of 38

Page 31: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

1.6 STAIRS, HANDRAILS, GUARDRAILSCommentsNo handrail is installed at front entry stairs. Consider installing a handrail for safety.

2. ROOFING

2.0 ROOFING MATERIALInspected(2) Moss is growing on the roof. Moss should be removed, also efforts should be taken to kill the moss during itsgrowing season (wet months). Typically zinc-based chemicals are used for this, and must be applied periodically.

2.2 CHIMNEYS AND FLUE PIPESComments(1) Excessive tar sealant has been applied at chimney flashing, evidence of past leaking in attic. I recommendhaving a roofing contractor evaluate, repair/replace flashing as needed.(2) Minor cracks/openings at top of chimney cap should be sealed with masonry caulk or suitable crack filler.

2.3 VENTS AND FLASHINGS (for ventilation systems and roof penetrations)CommentsRubber boots are cracked/deteriorated at plumbing vent flashings. Repair/replace vent flashings as needed.

2.4 GUTTERS AND DOWNSPOUTSCommentsGutters are full of leaves and debris. I recommend cleaning and maintaining on a regular basis.

3. ATTIC AND ROOF STRUCTURE

3.0 ATTIC AND ROOF STRUCTURECommentsOne of the roof rafters is lacking support, at side of chimney. I recommend installing additional support as needed.

4. ELECTRICAL SYSTEM

4.3 RECEPTACLES, SWITCHES, FIXTURES AND JUNCTION BOXESComments(1) Some of the homes receptacles are ungrounded (both 2-prong and 3-prong). This is most likely due to oldersections of wiring having only two wires and not a third ground wire. Electrical codes require ungroundedreceptacles to either be the 2-prong type or allow them to be converted to 3-prong receptacles if they are GFCIprotected. Be aware that any appliance with a 3-prong plug relies on grounding.(2) One of the basement bedrooms has no electric receptacles installed. The other basement bedroom has only onereceptacle installed.(3) Majority of basement rooms has older style pull chain light fixtures. No wall switches are installed.(4) Receptacle(s) are missing cover plates at one or more locations. Install cover plates where missing.

4.5 SMOKE DETECTORSCommentsSmoke alarms are not installed in bedrooms. Each bedroom should have an operational smoke alarm installed.

4.6 CARBON MONOXIDE DETECTORS

Blue Valley Home Inspection Sanguine

735 White Street Page 30 of 38

Page 32: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

CommentsA carbon monoxide detector should be installed at main floor hallway leading to bedrooms.

5. HEATING / AIR CONDITIONING

5.0 HEATING SYSTEMCommentsThe gas furnace is 25 years old, it operated when tested. Rust, corrosion, and moisture was found inside furnacecabinet. This is from flue condensation leaking. I recommend having a qualified HVAC contactor further evaluate,repair or replace furnace as needed.

5.5 COOLING AND AIR HANDLER EQUIPMENTNot InspectedThe A/C could not be tested for proper operation due to the outside air temperature below 60 degrees. We did notinspect this system.

6. PLUMBING / FUEL SYSTEMS

6.1 PLUMBING DRAIN, WASTE AND VENT SYSTEMSComments(1) Based on age of home, I recommend having a plumber perform a sewer scope inspection of main sewer line.According to home owner the main sewer line has been replaced.(2) Cast iron drain pipe is basement has rust and signs of past leaking. No leaks were detected at time of inspection.Old cast iron pipe will eventually need replaced.

6.2 WATER HEATERSComments(1) Both water heaters are past normal life expectancy. They were working at time of inspection, I am unable todetermine life remaining.(2) The water heaters do not have earthquake straps installed. Standard building practices require earthquakestraps to be installed to properly secure water heaters.(3) The water heater does not have a "Thermal Expansion tank" installed. Thermal expansion tanks are requiredwhen the incoming main water supply has a check flow valve for backflow prevention. If the water heater TPR valvebegins to drip or leak, then a thermal expansion tank may be needed.(4) Substandard wiring was found for the water heater's power supply. Exposed non-metallic sheathed (Romex)wiring is used. Typically, flexible conduit with bushings is used in this application.(5) No drain line is installed for the temperature-pressure relief valve. A drain line should be installed extending to 6inches from the floor.

6.4 EXTERIOR FAUCETS AND HYDRANTSCommentsExterior faucets are not the frost free type and will need winterized during freezing temperatures.

6.7 LAUNDRY/UTILITY SINKSCommentsLeaks were found at water supply connections below laundry sink. Low water pressure/flow detected at hot side.

7. KITCHEN COMPONENTS AND BUILT IN APPLIANCES

7.5 RANGE HOOD/EXHAUST FANComments

Blue Valley Home Inspection Sanguine

735 White Street Page 31 of 38

Page 33: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Kitchen exhaust fan vents into the attic. I recommend venting properly to exterior so that all moisture is ventedoutdoors.

8. BATHROOMS

8.6 SINKS AND RELATED PLUMBINGCommentsBasement bathroom: Sink leaks at wall drain connection below cabinet. Repair as needed.

8.7 EXHAUST FANSComments(1) Main floor bathroom exhaust fan vents into the attic. This is a conducive condition for wood destroying organismsdue to increased moisture levels in the attic. Exhaust fans should be vented properly to exterior, so that all moistureis vented outdoors.(2) Basement bathroom exhaust fan is not venting properly, no airflow was detected at exterior vent cap. Repairsshould be made so that all moisture is vented outdoors.

8.8 JETTED TUBInspected(2) The jetted tub needs cleaned and flushed, debris in water was found after operating tub. Jetted tubs requireperiodic cleaning and sanitizing. Jetted tub cleaners, chlorine bleach, or white vinegar may be used to clean andflush jets.

9. INTERIORS

9.3 STEPS, STAIRWAYS, BALCONIES AND RAILINGSCommentsNo guardrails are installed at open side of stairs. Standard building practices require guardrails to be installed atdrop-offs higher than 30 inches. Note that this is a safety concern for small children.

9.4 DOORS (REPRESENTATIVE NUMBER)CommentsNo doors are installed at basement rooms.

9.5 WINDOWS (REPRESENTATIVE NUMBER)Comments(1) Basement bedroom windows have inadequate egress in the event of a fire due to the opening size being toosmall. Bedroom windows should be easy to open, stay open by themselves, and have:

• A minimum width of opening of 20 inches• A minimum height of opening of 24 inches• A minimum net clear opening of 5.7 square feet

10. FOUNDATIONS, BASEMENTS, AND CRAWLSPACES

10.0 FOUNDATIONS, BASEMENTS, AND CRAWLSPACES (Report signs of harmful water intrusion or moisturerelated concerns)Comments(1) Basement has signs of past moisture penetration at north side. Old water stains found at lower edges of walls,wood paneling is damaged. Basement areas were dry at time of inspection.

Blue Valley Home Inspection Sanguine

735 White Street Page 32 of 38

Page 34: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

(2) White efflorescence (powder substance) was found in areas on basement walls (north side). This is commonlyfound in older homes. Efflorescence occurs as moisture passes through concrete leaving mineral and salt depositsbehind.

11. DETACHED GARAGE

11.3 FLOORCommentsCracks and settlement in concrete slab floor.

11.4 ENTRY DOORCommentsSide entry door was locked and was not opened. Door frame is damaged near latch.

11.8 WIRING, LIGHTS AND RECPTACLESComments(1) Substandard wiring, exposed Romex wiring is routed on garage walls. Conduit or armored cable should be usedin this type of application.(2) Receptacle(s) are missing cover plates at one or more locations. Install cover plates where missing.

11.9 GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTED RECEPTACLESCommentsGarage receptacles are not GFCI protected. For improved safety, I recommend installing GFCI protection at allgarage receptacles.

Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of theneed for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use;Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value ofthe property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system thatwas not observed; The presence or absence of pests such as rodents, or insects; or Cosmetic items, underground items, oritems not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculatethe strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that maydamage the property or its components or be dangerous to the home inspector or other persons; Operate any system orcomponent that is shut down or otherwise inoperable; Operate any system or component that does not respond to normaloperating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition orhazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil,water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances;Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefitof the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meettheir specific needs and to obtain current information concerning this property.

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Trent Tarter

Blue Valley Home Inspection Sanguine

735 White Street Page 33 of 38

Page 35: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Structural Pest Inspection Summary

3963 Old Milton Hwy.Walla Walla, WA 99362Phone: (509) [email protected]

Washington State Licensed Home Inspector #470 WSDA Structural Pest Inspector #71761Oregon State Licensed Home Inspector #213631

CustomerWilliam Sanguine

Address735 White Street

Walla Walla WA 99362

This Wood Destroying Organism Inspection Report only includes finding from accessible and visible areas on the day of theinspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: subareas less than 18 inches in height; attic areas less than five feet in height, areas blocked by ducts, pipes or insulation; areaswhere locks or permanently attached covers prevent access; areas where insulation would be damaged if walked on; areasobscured by vegetation. All inaccessible areas are subject to infestation or damage from wood destroying organisms. Theinspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of theinspection, nor perform destructive testing. Wood destroying organisms may infest, reinfest or become active at anytime. Nowarranty is provided as part of this inspection.

10. FOUNDATIONS, BASEMENTS, AND CRAWLSPACES

10.2 WOOD DESTROYING INSECTS AND ORGANISMSInspectedThere was no visible evidence of Wood Destroying Insects, past infestation and/or damage at this structure duringthis inspection.

10.3 LIMITATIONS AND INACCESSIBLE AREASNot InspectedThere's a small inaccessible crawlspace area below front living room. This area extends past basement. Acrawlspace vent is installed at exterior. Inaccessible crawlspace areas are excluded from the inspection.

Blue Valley Home Inspection Sanguine

735 White Street Page 34 of 38

Page 36: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

WAC 16-228-2045 requires that a diagram be prepared for WDO (Wood Destroying Organism) inspection reports. Acopy is available upon request.

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Trent Tarter

Blue Valley Home Inspection Sanguine

735 White Street Page 35 of 38

Page 37: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Trent Tarter3963 Old Milton Hwy.Walla Walla, WA 99362Phone: (509) [email protected] State Licensed Home Inspector #470 WSDA Structural Pest Inspector #71761Oregon State Licensed Home Inspector #213631

As part of my service, I sometimes provide approximate cost-of-repair estimates for particular items. Theseestimates should be considered as background information only. It is beyond the scope of my inspection andreport to supply you with accurate repair costs. Such estimates should be supplied by contractors whospecialize in this type of work. Our estimates should be used only as guidelines. If you intend to negotiatethe price of this property based on defects found during this inspection, we strongly suggest you obtain oneor more written bids from a licensed contractor(s).

Evaluations are made as to the present age and remaining economic life of an item, i.e. water heaters, roofs,plumbing, furnaces, etc. These evaluations are based on visual observation, industry averages and priorexperience. THEY ARE NOT OFFERED AS A WARRANTY OR CERTIFICATION OF REMAINING LIFE.

DisclaimerIn some cases, I may recommend you consult with a specialist, such as a structural engineer or licensedelectrician. Hiring a specialist can be a prudent means of providing some protection for your financialinvestment in this property. I DO NOT MAKE ANY TYPE OF WARRANTY OR GUARANTEE AS TO THECONDITION OF THE PROPERTY. SOME THINGS MAY REMAIN HIDDEN OR BECOME DEFECTIVE AFTER THEINSPECTION. IT IS NOT POSSIBLE TO DETECT EVERY DEFECT WITHIN A BUILDING DURING THE COURSEOF A GENERAL INSPECTION. THIS REPORT SHOULD BE USED IN CONJUNCTION WITH, AND NOT AS AREPLACEMENT FOR, A PRE-CLOSING WALK-THROUGH BY THE CLIENT.THIS INSPECTION IS NOT AN INSURANCE POLICY AGAINST HIDDEN DEFECTS OR CONDITIONS THAT ARENOT VISIBLE AND READILY APPARENT AT THE TIME OF INSPECTION.

THE COST OF THIS INSPECTION DOES NOT ENTITLE YOU TO ANY TYPE OF PROTECTION FROM HIDDENFLAWS AND DEFECTS. THIS INSPECTION DOES NOT TRANSFER YOUR ULTIMATE RESPONSIBILITY TO BLUEVALLEY HOME INSPECTION.

Blue Valley Home Inspection Sanguine

735 White Street Page 36 of 38

Page 38: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

Home Inspection Agreement

The address of the property inspected is: 735 White Street, Walla Walla, WA 99362.This agreement is made between Blue Valley Home Inspection, (Hereinafter known as "Inspector") andthe undersigned (hereinafter known as "Client").

The Parties Understand and Agree as follows:Inspector guarantees to perform a visual inspection of the home and to provide client with a writteninspection report identifying the defects that inspector both observed and deemed material. Inspectormay offer comments as a courtesy, but these comments will not comprise the bargained-for report. Thereport is only supplementary to the seller's disclosure.

Inspector agrees to perform the inspection in accordance to the current Standards of Practice forWashington State Licensed Home Inspectors. It is understood and agreed that the inspection will be ofreadily accessible areas of the building and is limited to visual observations of apparent conditionsexisting at the time of the inspection only. Latent and concealed defects are excluded from theinspection.

Client understands that the inspection will be performed in accordance to the aforementionedStandards, which contain certain limitations, exceptions, and exclusions.

This inspection and report do not address and are not intended to address the possible presence ordanger from any potentially harmful substances and environmental hazards including, but not limited toradon gas, lead paint, asbestos, urea formaldehyde, toxic or flammable chemicals, mold spores orwater and airborne hazards. Also excluded are inspections of and reporting on swimming pools, well/septic systems, security systems, central vacuum, water softeners, sprinkler systems, fire and safetyequipment.

The inspection and report are performed and prepared for the use of client, who gives inspectorpermission to discuss observations with real estate agents, owners, repairpersons, and other interestedparties. Inspector accepts no responsibility for use or misinterpretation by third parties.

The report is not a comprehensive evaluation of items to be inspected, but only of readily visible ordetectable conditions present at the time of the inspection. The report should not be considered aninsurance policy against conditions, which exist as to the items not inspected or to the future conditionof items inspected. The Company shall not be liable for the failure to report water leaks or evidence ofleakage, which were not apparent at the time of the inspection or concealed from view, but which maybecome evident at a later time. The parties agree that the inspector, assume no liability or responsibilityfor the cost of repairing or replacing any unreported defect or deficiency, either current or arising in thefuture or for any property damage, consequential damage or bodily injury of any nature.

A Wood Destroying Organism (WDO) structural pest inspection will be performed by Trent Tarter WSDAlicense #71761 using the Structural Inspection Standards of the Washington State Pest ControlAssociation.

The inspection and report are not intended or to be used as a guarantee or warranty, expressed orimplied, regarding the adequacy, performance or condition of any inspected structure, item or system.The inspector is not an insurer of any inspected conditions.

Blue Valley Home Inspection Sanguine

735 White Street Page 37 of 38

Page 39: The Faira TeamPlease contact us if you have any questions or would like more information. We're happy you've chosen a Faira Certified home and look forward to the opportunity of working

In the event of a claim against inspector, client agrees to supply inspector with the following: (1) Writtennotification of adverse conditions within 14 days of discovery, and (2) Access to the premises. Failure tocomply with the above conditions will release inspector and its agents from any and all obligations.

In the event that client fails to prove any adverse claims against inspector in a court of law, client agreesto pay all legal costs, expenses and fees of inspector in defending said claims.

If any court declares any provision of this Agreement invalid or unenforceable, the remaining provisionswill remain in effect. This agreement represents the entire agreement between the parties. No changeor modification shall be enforceable against any party unless such change or modification is in writingand signed by the parties. This Agreement shall be binding upon and enforceable by the parties andtheir heirs, executors, administrators, successors and assignees. Client shall have no cause of actionagainst inspector after one year from the date of the inspection.

The parties agree that this report is for the exclusive use of the client. The inspection report is not to berelied upon by any third party nor may it be transferred to a third party. Distribution of the contents ofthis report to any third party shall be the responsibility of the client.

The above is understood and agreed to, and client acknowledges receipt of a copy of this agreement.

Total Inspection Fee $450.00

Client Name(s): William Sanguine

Date October 16, 2019

Blue Valley Home Inspection Sanguine

735 White Street Page 38 of 38