4
II ® COM UL-Recognized Component ADVANCED SYSTEM FEATURES • Modular design for ease of installation and stacking flexibility • Space saving design for the greatest amount of power in a small footprint • Certified as NEBS Level 3 and compliant to Earthquake Risk Zone 4 in various system configurations • Exceeds 1997 UBC Zone 4 seismic requirements for at or below grade installations • Exceeds 2000/2003 IBC requirements for 125% g level • Tin-plated copper alloy connectors minimize maintenance • C&D Ohmic Ring™ for ease of maintenance readings. With specially adapted probes, only one technician is required to take readings. ADVANCED MATERIALS • Advanced micro-porous Absorbed Glass Mat separators for ultra-low float current — reduces grid corrosion for a long, usable service life • Proprietary calcium alloys to minimize positive grid corrosion and growth — maximizes battery life • Robust polypropylene container and cover — enhances product quality and improves strength of materials for safe operation with flammability rating UL94 VO, LOI>28% The msEndur II is the latest advancement in battery technology with enhanced features for COM applications. By combining the service life reliability of a flooded battery with the performance energy density of a valve-regulated battery, C&D has created the msEndur II — The True Long-Life Battery™. The msEndur II series of batteries are unmatched in power density with space saving modular designs and have a 20-year design life to reduce the total cost of ownership. With its much lower float current, the msEndur II yields significant electrical costs savings over its life making it the most environmentally 2V VRLA battery. APPLICATIONS Wireless • Wireline • Central Office • Mobile Switching Centers • PBX Systems • Microwave • Broadband Headend • Network Operation Ctrs • Data Centers For Commercial Applications Capacity : Monoblock 30 – 180 Ampere-Hours 2 Volt Cell 345 – 2180 Ampere-Hours 12-1116 • Highly efficient, proprietary plate processing for high utilization of active material — results in high energy density and low float current ADVANCED PROCESSES • Advanced formation process results in a narrow float voltage window making on-site float matching unnecessary • Highly controlled manufacturing processes for exceptional and consistent plate quality ADVANCED SERVICE LIFE & WARRANTY • Proprietary cell design and manufacturing process provides for 20 year design life and documented long-lasting service life • Industry leading warranty ADVANCED EXPERIENCE • Over 100 years of experience in the battery industry • The only producer and marketer of complete battery and electronics systems for total power solutions • Fully backed by a worldwide network for local service FEATURES & BENEFITS 12-1116/1013/CD www.cdtechno.com THE SERIES VRLA BATTERY THE TRUE LONG LIFE BATTERY TM

THE II SERIES VRLA BATTERY THE TRUE … environmentally 2V VRLA battery. APPLICATIONS ... AT-09P 259 170 1291 04 88 76 60 50 42 23 ... to 14.8 VDC/unit average at 77°F (25°C) Maximum

  • Upload
    dotruc

  • View
    236

  • Download
    0

Embed Size (px)

Citation preview

Page 1: THE II SERIES VRLA BATTERY THE TRUE … environmentally 2V VRLA battery. APPLICATIONS ... AT-09P 259 170 1291 04 88 76 60 50 42 23 ... to 14.8 VDC/unit average at 77°F (25°C) Maximum

II®

COM

UL-Recognized Component

ADVANCED SYSTEM FEATURES • Modular design for ease of installation and stacking flexibility • Space saving design for the greatest amount of power in a small footprint • Certified as NEBS Level 3 and compliant to Earthquake Risk Zone 4 in various system configurations • Exceeds 1997 UBC Zone 4 seismic requirements for at or below grade installations • Exceeds 2000/2003 IBC requirements for 125% g level • Tin-plated copper alloy connectors minimize maintenance • C&D Ohmic Ring™ for ease of maintenance readings. With specially adapted probes, only one technician is required to take readings. ADVANCED MATERIALS • Advanced micro-porous Absorbed Glass Mat separators for ultra-low float current — reduces grid corrosion for a long, usable service life • Proprietary calcium alloys to minimize positive grid corrosion and growth — maximizes battery life • Robust polypropylene container and cover — enhances product quality and improves strength of materials for safe operation with flammability rating UL94 VO, LOI>28%

The msEndur II is the latest advancement in battery technology with enhanced features for COM applications.

By combining the service life reliability of a flooded battery with the performance energy density of a valve-regulated battery, C&D has created the msEndur II — The True Long-Life Battery™.

The msEndur II series of batteries are unmatched in power density with space saving modular designs and have a 20-year design life to reduce the total cost of ownership.

With its much lower float current, the msEndur II yields significant electrical costs savings over its life making it the most environmentally 2V VRLA battery.

APPLICATIONS • Wireless• Wireline• Central Office• Mobile Switching Centers• PBX Systems• Microwave• Broadband Headend• Network Operation Ctrs• Data Centers

For Commercial Applications Capacity : Monoblock 30 – 180 Ampere-Hours 2 Volt Cell 345 – 2180 Ampere-Hours

12-1116

• Highly efficient, proprietary plate processing for high utilization of active material — results in high energy density and low float current

ADVANCED PROCESSES • Advanced formation process results in a narrow float voltage window making on-site float matching unnecessary • Highly controlled manufacturing processes for exceptional and consistent plate quality ADVANCED SERVICE LIFE & WARRANTY • Proprietary cell design and manufacturing process provides for 20 year design life and documented long-lasting service life • Industry leading warranty ADVANCED EXPERIENCE • Over 100 years of experience in the battery industry • The only producer and marketer of complete battery and electronics systems for total power solutions • Fully backed by a worldwide network for local service

FEATURES & BENEFITS

12-1116/1013/CD www.cdtechno.com

THE SERIES VRLA BATTERY THE TRUE LONG LIFE BATTERY TM

Page 2: THE II SERIES VRLA BATTERY THE TRUE … environmentally 2V VRLA battery. APPLICATIONS ... AT-09P 259 170 1291 04 88 76 60 50 42 23 ... to 14.8 VDC/unit average at 77°F (25°C) Maximum

FV/Cell Models 1 hr 2 hr 3 hr 4 hr 5 hr 6 hr 8 hr 10 hr 12 hr 24 hr

AT-07P 189 123 93 75 63 55 43 36 30 16 AT-09P 259 170 129 104 88 76 60 50 42 23 AT-11P 324 213 161 130 110 95 75 62 53 28AT-13P 352 228 172 139 117 101 80 66 56 30 AT-15P 454 298 225 182 154 133 105 87 74 40 AT-17P 505 327 247 200 168 145 115 95 81 43 AT-19P 583 383 290 234 198 171 135 112 95 51

1.75 AT-21P 631 409 309 250 210 182 144 119 101 54 AT-23P 713 468 354 287 241 209 165 136 116 62 AT-25P 757 491 370 299 252 218 172 143 122 65 AT-27P 843 553 418 339 285 247 195 161 138 73 AT-29P 884 573 432 349 294 255 201 166 142 76 AT-35P 1102 723 547 443 373 323 255 211 180 96 AT-39P 1199 777 586 474 399 345 273 226 193 103

AMPERES @ 77°F (25°)

Constant Current Discharge Ratings

Constant Power Discharge Ratings

Please refer to the msEndur ll Stackable Module System with Module Dimensions and Weights brochure, 12-1014, for a listing of typical msEndur ll Module Systems dimensions and weights. Please refer to the msEndur II Performance Specifications Brochure, 12-1015, for an expanded list of constant power and constant current ratings and end voltages. You may also access the product ratings by logging onto the C&D Battery Sizing Program at www.cdstandbypower.net

Specifications and Characteristics

AT-07P ATL-07P AT-09P

ATL-09P AT-11P ATL-11P AT-13P

ATL-13P AT-15P ATL-15P

AT-17P ATL-17P AT-19P

ATL-19P AT-21P ATL-21P AT-23P

ATL-23P AT-25P ATL-25P AT-27P

ATL-27P AT-29P ATL-29P AT-35P

ATL-35P AT-39P ATL-39P

Number of Terminals 2 2 2 2 2 2 4 4 4 4 4 4 4 4

8 Hr AH Rate to 1.75

v/c @ 77°F (25°C)

345 / 295 480 / 390 600 / 490 640 / 515 840 / 685 920 / 780 1080 / 880 1150 / 980 1320 / 1075 1380 / 1175 1560 / 1270 1605 / 1370 2040 / 1660 2180 / 1855

10 Hr AH Rate to 1.80

v/c @ 68°F (20°C)

330 / 275 460 / 365 575 / 460 610 / 485 800 / 645 875 / 735 1030 / 825 1095 / 920 1315 / 1100 1490 / 1195 1535 / 1285 1945 / 1560 2085 / 1745

AT-P = 2.25 - 2.27 volts per cell average @ 77°F (25°C) ATL-P = 2.17 - 2.22 volts per cell average @ 77°F (25°C) (-)2 mV/cell/°F above 77°F (-3.6 mV/cell /°C above 25°C) +2 mV/cell/°F below 77°F (+3.6 mV/cell/°C below 25°C)

Recommended Float Charging Voltage (ATL Recommended Float Voltage) Charger Compensation Temperature / Voltage

Cells, Voltage per Unit 1 cell, 2 VDC Energy Saving Operating Temperature Connection Torque: 77°F (25°C)

Initial: 160 in-lbs (18 N-m), Re-torque: 125 in-lbs (14 N-m)

1260 / 1010

FV/Cell Models 1 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr AT-07P 0.837 0.791 0.730 0.669 0.612 0.520 0.430 0.373 AT-09P 1.117 1.055 0.973 0.892 0.816 0.693 0.574 0.497 AT-11P 1.396 1.318 1.217 1.115 1.020 0.866 0.717 0.622AT-13P 1.558 1.471 1.358 1.244 1.138 0.967 0.800 0.694 AT-15P 1.954 1.846 1.704 1.561 1.427 1.213 1.004 0.870 AT-17P 2.233 2.110 1.947 1.784 1.631 1.386 1.147 0.995 AT-19P 2.512 2.373 2.190 2.007 1.835 1.559 1.291 1.119 AT-21P 2.792 2.637 2.434 2.230 2.039 1.733 1.434 1.243 AT-23P 3.071 2.901 2.677 2.452 2.243 1.906 1.578 1.368 AT-25P 3.350 3.164 2.920 2.675 2.447 2.079 1.721 1.492 AT-27P 3.629 3.428 3.164 2.898 2.651 2.253 1.864 1.617 AT-29P 3.908 3.692 3.407 3.121 2.855 2.426 2.008 1.741 AT-35P 2.946 2.438 2.114 AT-39P 2.725 2.363

KILOWATTS PER CELL @ 77°F (25°C)

1.67

12-1116/1013/CD 2 www.cdtechno.com

Page 3: THE II SERIES VRLA BATTERY THE TRUE … environmentally 2V VRLA battery. APPLICATIONS ... AT-09P 259 170 1291 04 88 76 60 50 42 23 ... to 14.8 VDC/unit average at 77°F (25°C) Maximum

MonoblockModel

Ampere Hour Capacity to 1.75 Volts per Cell @ 77°F (25°C) 1 hr 2 hr 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 10 hr 12 hr 20 hr 24 hr 100 Hr

TEL12-30 22.1 25.9 27.6 28.6 29.1 29.5 29.9 30.4 31.1 31.8 33 33.2 34 TEL12-45 31.5 37 39.6 41 42.3 43.4 44.4 45.5 46.9 47.8 50 50.4 52 TEL12-70 46.8 55 59.5 62.2 64.3 66 67.5 69.1 71 72.1 75 75.6 78 TEL12-80 53.8 63 67.8 70 72.5 75 77 79 81.4 83 88 88.3 92 TEL12-90 60 69.6 75 79 81 83.7 85.8 87.6 90.8 93.5 100 101 104 TEL12-125 87.5 98 108 113.6 118 121.2 123.5 126 128 130 134.8 136.3 146 TEL6-180 120 137 150 156.8 162 168 172.2 175.5 181 186.5 200 20.1 208

II® TEL MONOBLOCK

Technical Data

Specifications

12-1116/1013/CD 3 www.cdtechno.com

Monoblock

Model Volt Per Unit (V)

Capacity (C8 /1.75V

@25°C) (AH)

Dimensions (L*W*H*Total Height)

(mm) Internal

Imp. (mΩ)

Short Circuit Current

(A)

Maximum Discharge Current (A)

TEL12-30 12 30 197 132 166 173 6.2 2150 500 TEL12-45 12 45 229 139 200 205 6.0 2500 600 TEL12-70 12 70 261 174 200 204 5.0 3100 800 TEL12-80 12 80 306 174 202 205 3.6 3300 800 TEL12-90 12 90 341 173 213 216 3.5 3600 800 TEL12-125 12 125 345 173 275 278 2.3 5000 800 TEL6-180 6 180 321 177 223 227 1.2 4350 800

lbs kg

27.3 12.4 40.6 18.4 55.8 25.3 66.6 30.2 74.5 33.8

102..3 46.4 74.5 33.8

Weight

Container & Cover Material PP (UL94-V0) Electrolyte Absorbed H2SO4; SG-1.300 Operating Temperature Range (with temperature compensation) Discharge: -40°F (-40°C) to +160°F (71°C); Charge: -10°F (-23°C) to +140°F (60°C) Normal Operating Temperature Range +74°F (23°C) to +80°F (27°C) Recommended Maximum Charging Current Limit C20/5 amperes

Float Charging Voltage 13.5 to 13.8 VDC/unit average at 77°F (25°C) Equalization and Cycle Service Charging and Current Limits 14.4 to 14.8 VDC/unit average at 77°F (25°C) Maximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results;

Maximum voltage allowed = 4% P-P; Maximum current allowed = C/20 RMS Self Discharge

Up to 6 months at 77°F (25°C) and then a freshening charge is required. Batteries stored at temperatures at greater than +77°F (25°C) will require recharge sooner than batteries stored at temperatures less than 77°F (25°C).

Accessories Rack systems are available for all models Terminal: Inserted

Threaded copper alloy insert terminal to accept; 10-32 UNF x ⅜ in. long screws (12-30 &12-45); 1/4-20 UNC x ¾ in. long screws (12-70,12-80,12-90, 12-125 & 6-180)

Terminal Hardware Torque 25 in.-lbs (2.8 N-m) (12-30 & 12-45); 110 in.-lbs (12.4 N-m) (12-70,12-80,12-90,12-125 & 6-180)

• True Long Life msEndur Families, Monoblock design to minimize space required and maximize of energy density.• Telecordia certified life up to 13 years service life at 25 deg C.• Telecordia tested and qualified to meet all SR-4228 requirements.• UL Recognized Flame-arresting, one-way pressure-relief vent for safety and long life.• Thermally welded case-to-cover bond to ensure a leak-proof seal.• Flame-retardant polypropylene case and cover compliant with UL94 V-0 with an Oxygen Limiting Index of greater than 28.

Page 4: THE II SERIES VRLA BATTERY THE TRUE … environmentally 2V VRLA battery. APPLICATIONS ... AT-09P 259 170 1291 04 88 76 60 50 42 23 ... to 14.8 VDC/unit average at 77°F (25°C) Maximum

1400 Union Meeting RoadP.O. Box 3053 • Blue Bell, PA 19422-0858(215) 619-2700 • Fax (215) 619-7899 • (800) [email protected] Copyright 2013 C&D Technologies, INC. Printed in U.S.A. 1013/CD

Any data, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application.

FV/Cell ModelMonoblock

3 hr1 hr 2 hr 4 hr 5 hr 6 hr 7 hr 8 hr 10 hr 12 hr 20 hr 24 hr

1.75

TEL12-30 22.1 13.0 9.2 7.2 5.8 4.9 4.3 3.8 3.1 2.7 1.7 1.4 TEL12-45 31.5 18.5 13.2 10.3 8.5 7.2 6.3 5.7 4.7 4.0 2.5 2.1 TEL12-70 46.8 27.5 19.8 15.6 12.9 11.0 9.6 8.6 7.1 6.0 3.8 3.2 TEL12-80 53.8 31.5 22.6 17.5 14.5 12.5 11.0 9.9 8.1 6.9 4.4 3.7 TEL12-90 60.0 34.8 25.0 19.8 16.2 14.0 12.3 11.0 9.1 7.8 5.0 4.2 TEL12-125 87.5 49.0 36.0 28.4 23.6 20.2 17.6 15.8 12.8 10.8 6.7 5.7 TEL6-180 120.0 68.5 50.0 39.2 32.4 28.0 24.6 21.9 18.1 15.5 10.0 8.4

1.80

TEL12-30 21.0 12.4 8.8 6.9 5.6 4.7 4.1 3.7 3.0 2.6 1.6 1.4 TEL12-45 30.0 18.0 13.0 10.0 8.2 7.1 6.2 5.5 4.6 3.9 2.5 2.1 TEL12-70 44.5 26.8 19.2 15.0 12.3 10.6 9.3 8.4 6.9 5.9 3.7 3.1 TEL12-80 51.1 29.8 21.6 17.0 14.0 12.2 10.7 9.6 7.9 6.7 4.3 3.6 TEL12-90 57.0 33.0 24.0 19.0 15.6 13.4 11.9 10.6 8.8 7.6 4.9 4.1 TEL12-125 82.5 47.3 34.7 27.5 22.7 19.5 17.0 15.2 12.4 10.6 6.6 5.6 TEL6-180 113.0 66.0 48.0 38.0 31.4 27.0 23.7 21.2 17.6 15.1 9.7 8.2

1.85

TEL12-30 19.6 11.6 8.4 6.6 5.4 4.6 4.0 3.5 2.9 2.5 1.6 1.3 TEL12-45 28.0 17.4 12.7 9.9 8.1 6.9 6.0 5.4 4.4 3.8 2.3 2.0 TEL12-70 41.8 25.5 18.3 14.3 11.9 10.2 9.0 8.1 6.6 5.6 3.5 3.0 TEL12-80 47.0 27.5 20.3 16.1 13.4 11.6 10.3 9.1 7.5 6.4 4.1 3.5 TEL12-90 53.3 31.4 22.8 18.0 15.0 12.8 11.3 10.1 8.4 7.2 4.7 4.0 TEL12-125 77.0 44.0 32.5 26.3 21.8 18.7 16.3 14.5 11.9 10.1 6.4 5.4 TEL6-180 106.0 62.0 45.5 36.0 30.0 25.8 22.7 20.3 16.9 14.5 9.3 7.8

1.90

TEL12-30 18.5 11.1 8.0 6.4 5.2 4.4 3.8 3.4 2.8 2.4 1.5 1.3 TEL12-45 26.2 16.5 12.2 9.5 7.8 6.7 5.9 5.2 4.3 3.6 2.2 1.9 TEL12-70 39.5 24.2 17.3 13.6 11.3 9.7 8.6 7.7 6.4 5.4 3.4 2.9 TEL12-80 43.0 25.4 18.5 15.0 12.5 10.8 9.5 8.5 7.0 5.9 3.9 3.3 TEL12-90 49.5 29.9 21.7 17.1 14.2 12.1 10.6 9.5 7.9 6.7 4.3 3.7 TEL12-125 71.0 41.5 30.7 24.3 20.2 17.2 15.1 13.4 11.0 9.4 6.0 5.1 TEL6-180 94.0 57.3 42.0 33.5 27.9 24.0 21.1 19.0 15.8 13.7 8.9 7.6

Constant Current Discharge Table - Amps @ 25°C (77°F)

Constant Power Discharge Table –Watts Per Cell @ 25°C(77°F)

FV/Cell 5 min 10 min 15 min 20 min 25 min 30 min 45 min 60 min 90 min

1.67

TEL12-30 235.0 159.0 125.0 101.8 88.2 74.5 55.5 45.1 33.8 TEL12-45 279.8 207.1 170.0 140.5 123.4 106.3 80.0 64.9 47.3 TEL12-70 437.3 312.4 250.7 207.1 182.0 156.8 117.7 95.9 69.5 TEL12-80 525.0 365.0 285.2 235.4 206.7 178.0 134.4 108.0 79.5 TEL12-90 565.0 420.0 330.0 277.6 242.8 208.0 153.9 123.1 89.1 TEL12-125 749.5 576.6 474.8 393.4 347.5 301.6 226.6 181.9 128.7 TEL6-180 938.0 747.9 620.0 526.4 469.9 413.3 306.1 245.1 174.0

1.70

TEL12-30 229.4 155.8 122.4 99.6 86.3 73.0 54.5 44.3 33.2 TEL12-45 271.7 203.4 166.8 138.4 121.3 104.1 78.2 63.8 46.7 TEL12-70 420.8 304.9 244.1 203.2 178.5 153.8 114.7 93.2 68.2 TEL12-80 510.0 354.2 279.3 231.6 203.4 175.2 132.9 107.0 79.0 TEL12-90 540.0 398.7 317.6 269.2 236.6 203.9 151.5 121.2 87.6 TEL12-125 725.0 542.9 451.5 379.2 336.2 293.2 221.6 177.8 125.0 TEL6-180 890.0 720.0 600.1 514.1 460.0 405.8 301.6 241.3 170.5

1.75

TEL12-30 224.7 153.5 119.7 96.8 83.9 71.0 53.0 43.4 32.3 TEL12-45 249.6 189.4 159.6 134.5 118.0 101.5 76.3 61.5 45.3 TEL12-70 391.2 288.9 238.6 198.8 175.2 151.6 112.9 91.9 67.7 TEL12-80 464.9 340.0 272.3 227.2 200.1 173.0 131.1 105.6 77.6 TEL12-90 510.0 375.0 304.7 264.3 232.1 199.9 147.9 117.8 85.5 TEL12-125 685.0 515.0 437.3 366.3 324.9 283.4 217.3 172.8 122.8 TEL6-180 862.5 680.6 575.4 492.6 443.6 394.6 296.1 237.6 168.3

1.80

TEL12-30 211.8 141.0 111.9 93.5 80.9 68.4 50.8 41.4 31.0 TEL12-45 224.2 170.0 146.2 126.4 111.6 96.9 73.3 59.2 43.6 TEL12-70 349.2 262.4 219.1 185.2 162.9 140.6 107.4 87.8 65.7 TEL12-80 415.1 304.8 254.6 218.5 192.3 166.0 126.0 100.8 73.3 TEL12-90 430.1 333.4 279.7 244.7 217.1 189.4 141.4 112.5 81.8 TEL12-125 579.7 457.2 395.4 340.8 303.0 265.2 203.0 162.8 116.8 TEL6-180 729.3 619.1 532.4 466.0 416.6 367.1 278.9 222.9 162.3

ModelMonoblock