Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
1
>InsulatIon
>�aIrtIghtness,waterproofIngand
moIstureproofIng
>aIrqualItyandventIlatIon
>doorsandwIndows
>heatIngofwaterandspaces
>qualItycontrol
>summary
formoreInformatIon:
www.efficaciteenergetique.mrnf.gouv.qc.ca�1-866-266-0008
thInKIngofBuyInganewhouse?comparebeforeyoubuy
TM
Choose�a�seCtion�
>
youwouldlikeaqualityhouseatthebestpossibleprice? ask your builder the appropriate questionsand compare the different options that aresuggestedtoyou.evaluatealloffersbeforesigningasalesorbuildingcontractwithyourcontractor.theseare the steps all informed consumers should takewhenconsideringthepurchaseofanewhousethatiscomfortable,healthyandenergy-efficient.
2
InsulatIon
yourhousemustbecontinuouslyinsulatedfrombasementtoattic.thiseliminatescoldfloors,condensationandtheformationofmould,andlowersyourheatingcosts.
Novoclimat Proposal 1
Proposal 2
thebasement�floorisinsulatedwithinsulation(minimumrsI0.88(r-5))thatcoversthefoundationfooting.
thefoundationisinsulatedfromtoptobottom(minimumrsI2.99(r-17)).
theoutside�wallsarewellinsulated(minimumrsI4.31(r-24.5)).
thehouse�structureisprotectedagainstthecold(minimumrsI0.7(r-4).
• Basementwalls
• above-groundwalls
• floors
theroofisinsulated(minimumrsI7.22(r-41))andwellventilated.
number�of�items�checked / / /
R
RSI 1,
WallsRSI 4.31(R-24.5)(including
insulation over thermal bridges)
FoundationsRSI 2.99
(R-17)
Under the slabRSI 1.32 (apartment building)
(R-7.5)or
RSI 0.88 (single-family house)
(R-5)
Ceiling with superiorinsulation
Basement wall framing protected against the cold
Outside wall framing protected against the cold
Floor framing better protected against the cold
Foundation wallinsulated along its entireheight with a superior levelof insulation
Insulation covering the footing
Basement floor entirelyinsulated
Reduces heat loss through the walls and roofReduces the risk of hidden condensation in the walls and roof spaceReduces the risk of condensation andmould at the base of the wallsPrevents the basement floor slabfrom getting cold due to contact withthe footingKeeps the floor near the foundation wall and exterior walls warmerEliminates the feeling of cold anddampness in the basement
Advantages
Continuous insulationprovides betterprotection for thehouse and greatercomfort to the occupants
Roof spaceRSI 7.22
(R-41)
3
aIrtIghtness,waterproofIngandmoIstureproofIng
theconcreteslabinthebasementmustbebuilttopreventwaterseepage,thusreducingtheriskofexcessivemoisture.thewallsandceilingsmustbesealedtopreventdrafts,whichincreaseheatingbills.adequatewaterproofingandairtightnesshelpavoidtheinconvenienceofcondensationandmould.
Novoclimat Proposal 1
Proposal 2
thebasement�slabisprotectedbyanairtightvapourbarrier.
theexterior�walls�and�the�ceilingsarebuiltinaccordancewithanairtightnesstechniquethatisrecognizedinthebuildingindustry.
thehouse’sairtightnessisverifiedbyanindependentexpertusingablower�door�test.
thehouse’sairtightnessfactorisamaximumof2.5�air�changesperhour.
number�of�items�checked / / /
4
aIrqualItyandventIlatIon
toimproveairqualityandavoidhealthandmoistureproblems,makesurethatthereiscontrolledventilationandfreshairintakeinthemainrooms.thetypeofequipmentselectedandthequalificationsoftheprofessionalsdoingtheinstallationarealsoimportantfactorstoconsiderer.
Novoclimat Proposal 1
Proposal 2
theventilation�systemcomplieswiththerequirementsofthe1995nationalBuildingcode.Itincludesfreshairventinginthemainrooms.
theventilationsystemisinstalledbyacertifiedventilation�expert,whohasreceivedspecifictrainingwithrespecttonovoclimatandtherequirementsofthe1995nationalBuildingcode.
theventilationsystemisequippedwithaheat�recovery�ventilator(hrv)certifiedbythehomeventilatingInstitute(hvI).Itsheatrecoveryefficiencyisequaltoorhigherthan60%atanoutdoortemperatureof–25°c.
theventilationsystem’sductsystemismadeofrigid,airtightductsthatcanbecleanedasrequired
whentheventilationsystemisinstalled,theair�out-takesaremeasuredandgaugedwithappropriateinstruments.
Ifthehousehasanattachedgarageoracombustion�appliance,acarbondioxidedetectormustbeinstalled.
number�of�items�checked / / /
Ensures good air quality for occupants and adequate air distribution throughoutthe house
Circulation of fresh air in allbedrooms and the living room
Certified unit with superiorperformanceEnergy saving heatrecovery core
Central ventilation systemwith heat recovery ventilator
Provides more effective moisture andodour controlReplaces noisy, high energy-consumingautonomous fans
Excess moisture evacuated viathe bathrooms
Outdoor fresh air intake located far from any contaminants
Prevents unpleasant drafts and ensures greater comfort in all roomsGuarantees proper operation of the unitEnsures maximum heat recovery
Complete balancing of all air flows
Allows for the selection ofoperating mode based onspecific needsAllows for the addition of afilter using the “recirculation”moderequired by the Novoclimat Program
Multifunction ventilation control
®
5
doorsandwIndows
selectinsulatedsteeldoorsthatofferbetterresistancetodeformationwhichcanreducedoorairtightness.high-performancewindowsthatareinstalledwithcarecanloweryourheatingcosts,increasecomfortlevelsandconsiderablyreducecondensationandtheformationofmould.
Novoclimat Proposal 1
Proposal 2
exterior�doorsaremadeofsteel,insulatedwithpolyurethaneandcomplywithstandardcan/cgsB-82.5-m88.
high-performancewindows:
• glasssealedwithargon
• lowemissionsealant
• Insulatingspacers
• a2airtightness(standarda440)
number�of�items�checked / / /
Low expansionfoamed polyurethane insulation
Inert gas between the panes increases the thermal resistanceof the window
Sealed double glazing with argon
Prevents excessive cold around window edges and at the junctionof window framesSignificantly reduces condensation at the bottom of the window
Insulating glass spacer
Windows laboratory tested to A440 to garantee a good sealagainst cold air infiltrations
Improved air tightness
Installation in the warm part of the wall which reduces therisk of condensationSuperior air/vapour tightnessand insulation around thewindow frame with low expansion polyurethane
Stricter installation requirements
Significantly reduces heat loss and eliminates the sensation of cold near windowsSignificantly reduces condensation and helps maintain winter humidity levels at a comfortableand healthy levelLengthens the service life of windows, reduces maintenance and delays replacement
Interior surface of windowmuch warmer in winter
Transparent film that:
Also reflects part of the sun’s raysthus reducing the risk ofoverheating in summer
Low-e coating
Reflects heat back inside
INSIDE
6
heatIngofwaterandspaces
thequalityof theheatingsystems isevaluatedbytheuseofeffectiveappliancesthatdonotuseenergyunnecessarilyandthatkeeptemperaturesconstant.
Novoclimat Proposal 1
Proposal 2
electricheatingappliancesareequippedwithelectronic�thermostatsandthecentralheatingsystemisequippedwithaprogrammable�thermostat.
Ifthehomehasawood-burningappliance,itmustuseadvancedcombustion;ifitcontainsawoodstove,itmustbecertifiedbytheepaorbycsaB415.1-m-92.
Ifthehousehasagas�or�oilfurnace,combustionisinasealedcircuitwithdirectoutdooremissions
Ifthehousehasacombustionheatingsystem,ananalysisofbackdraftsintothehouse(suchaswhenusingapowerfulkitchenrangehood)mustbeconducted.
number�of�items�checked / / /
7
qualItycontrol
a reliable professional who is specially mandated will inspect your home to identify the corrective measures to carry out before theconstructioniscomplete.whatismore,bychoosingabuilderwhoisrecognizedintheconstructionof“energyefficienthomes”,youwillbesuretohaveaqualityhomethatprovidescomfortandenergysavings.
Novoclimat Proposal 1
Proposal 2
thebuilderhasalicensethatisrecognizedbytherégiedubâtimentandisregisteredwithawarranty�programfornewhouses.
thebuilderistrainedandcertifiedtobuildnovoclimathouses.
theenergyefficiencyofthehouseisinspectedbyanindependentprofessionalwhoismandatedbytheministèredesressourcesnaturellesetdelafaune.
thehome’scompliancetonovoclimatrequirementsisofficially�certifiedbytheministèredesressourcesnaturellesetdelafaune.
number�of�items�checked / / /
8
Novoclimat Proposal 1
Proposal 2
totalnumberofelementschecked / / /
savingsonheatingcosts* 25%* n/a n/a
novoclimatinspectionandcertification Free n/a n/a
*dependingonweatherconditionsandyourconsumptionhabits.
notIce
theelementsofthislistarecompulsorytechnicalfeaturesofthenovoclimathouse.novoclimathomesareinspectedfortheirenergyefficiencyandcertifiedbytheministèredesressourcesnaturellesetdelafaune.
someoftheserecommendationsareinadditiontotheprovisionsoflocalbuildingcodes,ofquebecbuildingstandardsaswellasthoseofthenationalBuildingcodeineffect.
as� regards� novoclimat� pre-fabricated� houses,� performance� certification� only� covers� the� products� that� leave� the� plant,� if� the�foundations�and�their�insulation�as�well�as�other�components�are�under�the�responsibility�of�the�buyer.�For�the�house�to�receive�complete�certification,�all�work�pertaining�to�novoclimat�requirements�must�be�carried�out�by�a�novoclimat-certified�contractor.
Summary...
fInancIalassIstanceIsavaIlaBletopersonsBuyIng
anewnovoclImathome.
aSk uS about it today!