TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81 ST REGIONAL SUPPORT COMMAND ARCHITECTURAL LINDBERGH & ASSOCIATES, LLC 2170 ASHLEY PHOSPHATE RD, 5TH FLOOR CHARLESTON, SOUTH CAROLINA 29406 LOCATION OF SITE VICINITY MAP LOCATION OF SITE 160 WHITE BRIDGE ROAD NASHVILLE, TN 37416 DRAWING INDEX SHEET TITLE TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES G-001 COVER SHEET & DRAWING INDEX G-002 SCOPE OF WORK & GENERAL NOTES H-101 ASBESTOS & LEAD-BASED PAINT SAMPLE LOCATIONS H-102 ABATEMENT PLAN A-001 ARCHITECTURAL ABBREVIATIONS A-002 GENERAL NOTES AD101 AMSA - FAC 00002 DEMOLITION PLAN AD901 DEMOLITION PHOTOS A-101 AMSA - FAC 00002 FLOOR PLAN A-121 AMSA - FAC 00002 REFLECTED CEILING PLAN A-131 CEILING DETAILS A-401 AMSA - FAC 00002 ENLARGED PLANS & ELEVATIONS A-501 DOOR AND WINDOW ELEVATIONS & DETAILS A-502 DOOR & WINDOW DETAILS A-503 WINDOW DETAILS P-101 AMSA - FAC 00002 PLUMBING PLANS E-001 SYMBOLS AND ABBREVIATIONS ED101 POWER & LIGHTING DEMOLITION PLAN E-101 ELECTRICAL NEW WORK PLAN E-501 DETAILS E-601 DIAGRAMS E-602 MISCELLANEOUS SCHEDULES LOCATION MAP PLUMBING / ELECTRICAL O'BRIEN & GERE ENGINEERS, INC. 2170 ASHLEY PHOSPHATE RD, 5TH FLOOR CHARLESTON, SOUTH CAROLINA 29406 *** Safety Pays *** *** Support Value Engineering - It Pays *** SOLICITATION NO.: FILE NAME: DWN BY: CKD BY: DESIGNED BY: DESCRIPTION 1 D 2 3 C 4 5 A B MARK APPR. DATE: FILE NUMBER: SIZE: SUBMITTED BY: PLOT SCALE: PLOT DATE: DATE MARK DESCRIPTION CONTRACTOR NO.: SHEET IDENTIFICATION DATE APPR. SHEET OF US Army Corps of Engineers I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.G001.DWG 8/1/2013 12:02:40 AM 81ST RSC RESET PROJECTS - TN COVER SHEET & DRAWING INDEX G-001 NEK ECN LINDBERGH & ASSOCIATES AS NOTED ANSI D 50740.TN116.G001.DWG 8/1/2013 DLB AUGUST 1, 2013 CHARLESTON DISTRICT CHARLESTON DISTRICT 1 22

TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

TN116 - LIGHTING, LATRINE, WINDOW UPGRADE

WITH CEILING TILES

160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416

81

ST

REGIONAL SUPPORT COMMAND

ARCHITECTURAL

LINDBERGH & ASSOCIATES, LLC

2170 ASHLEY PHOSPHATE RD, 5TH FLOOR

CHARLESTON, SOUTH CAROLINA 29406

LOCATION OF SITE

VICINITY MAP

LOCATION OF SITE

160 WHITE BRIDGE ROAD

NASHVILLE, TN 37416

DRAWING INDEX

SHEET TITLE

TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES

G-001 COVER SHEET & DRAWING INDEX

G-002 SCOPE OF WORK & GENERAL NOTES

H-101 ASBESTOS & LEAD-BASED PAINT SAMPLE LOCATIONS

H-102 ABATEMENT PLAN

A-001 ARCHITECTURAL ABBREVIATIONS

A-002 GENERAL NOTES

AD101 AMSA - FAC 00002 DEMOLITION PLAN

AD901 DEMOLITION PHOTOS

A-101 AMSA - FAC 00002 FLOOR PLAN

A-121 AMSA - FAC 00002 REFLECTED CEILING PLAN

A-131 CEILING DETAILS

A-401 AMSA - FAC 00002 ENLARGED PLANS & ELEVATIONS

A-501 DOOR AND WINDOW ELEVATIONS & DETAILS

A-502 DOOR & WINDOW DETAILS

A-503 WINDOW DETAILS

P-101 AMSA - FAC 00002 PLUMBING PLANS

E-001 SYMBOLS AND ABBREVIATIONS

ED101 POWER & LIGHTING DEMOLITION PLAN

E-101 ELECTRICAL NEW WORK PLAN

E-501 DETAILS

E-601 DIAGRAMS

E-602 MISCELLANEOUS SCHEDULES

LOCATION MAP

PLUMBING / ELECTRICAL

O'BRIEN & GERE ENGINEERS, INC.

2170 ASHLEY PHOSPHATE RD, 5TH FLOOR

CHARLESTON, SOUTH CAROLINA 29406

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.G001.DWG

8/1/2013 12:02:40 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

CO

VE

R S

HE

ET

&

D

RA

WIN

G IN

DE

X

G-001

NE

K

EC

N

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.G

001.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

122

Page 2: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

SYSTEM NO. C-AJ-1175

F RATING - 2 HR

T RATING - 0 HR

W RATING - CLASS I (SEE ITEM 4)

SECTION A-A

SECTION A-A

A

2

4

FIRESTOP CONFIGURATION - B

FIRESTOP CONFIGURATION - A

A

2

4

A

1A

A

1A

3

4

2

4

1

31

SECTION A-A

3C

3B3A

1A

3C

2

1B

A

A

SYSTEM NO.W-L-1003

(FORMERLY SYSTEM NO. 147)

F RATINGS - 1 AND 2 HR (SEE ITEM 1)

T RATING - 0 HR

SECTION A-A

A

A

3A

3B

2

1A

1B

SYSTEM NO. W-L-7191

T RATING - 0 HR

F RATING - 1 AND 2 Hr (SEE ITEM 1)

L RATING AT AMBIENT - LESS THAN 1 CFM/sq ft

L RATING AT 400°F - LESS THAN 1 CFM/SQ FT

SYSTEM NO. C-AJ-0070

F RATING — 2 HR

T RATING — 2 HR

A

A

12B

2A

2

SECTION A-A

ROOF ASSEMBLY

FLUTED STEEL DECK

CMU WALL WITH 1 HR

RATING - SEE WALL

TYPES

MINERAL WOOL

PACKING

RATED WALL DESIGN:

1 HR RATED CMU;

BASED ON UL DESIGN NO. U 905

SPRAYED 3M FIRE

BARRIER OR EQUAL,

EACH SIDE

5/8" TYPE "X", EACH SIDE

METAL FRAMING @ 16" OC

BRACE AT 4'-0" O.C. EA SIDE

RATED WALL DESIGN:

1 HR RATED GWB ASSEMBLY;

BASED ON UL DESIGN NO. U 465

SPRAYED 3M FIRE BARRIER

OR EQUAL, EACH SIDE

STEEL DECK

ROOF ASSEMBLY

LOCATION OF SITE:

160 WHITE BRIDGE ROAD

NASHVILLE, TN 37416

BUILDING INDEX

FAC NO BUILDING

00002 AMSA

SITE AERIAL

TYPICAL DETAILS:

NOT TO SCALE

TYPICAL FLOOR/WALL

PENETRATION DETAIL

1

NOT TO SCALE

TYPICAL WALL

PENETRATION DETAIL

2

NOT TO SCALE

TYPICAL WALL

PENETRATION DETAIL

3

NOT TO SCALE

TYPICAL FLOOR/WALL

PENETRATION DETAIL

4

NOT TO SCALE

TYPICAL TOP OF WALL DETAIL

5

00002 - AMSA

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.G002.DWG

8/1/2013 12:02:46 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

SC

OP

E O

F W

OR

K &

G

EN

ER

AL N

OT

ES

G-002

KE

M

DA

L

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.G

002.D

WG

8/1/2013

CW

W

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

D

ENCLOSURE CLASSIFICATION: C, ENCLOSED

BUILDING CATEGORY: II

ASSUMED BASIC WINDSPEED: 90 MPH

COMPONENTS & CLADDING @ ZONE AREA 5 = -25.0 PSF

SEISMIC DESIGN CATEGORY

WINDLOADS

222

Page 3: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

C

B

A

1 2 3 4 5 6 7 2

D

C

B

A

1

WORK BAYS

100

OFFICE

AMSA

116OFFICE

OMS

115

BREAK

113

MECH

111

CORR

114

BATT

102

STOR

103

TOOL

104

TOOL

105

WOMEN'S

112

MEN'S

106

LOCKERS

107

MOTOR POOL

108

FLAM STOR

110

FLAM STOR

109

WASH RACK

200

WORK

100A

ASBESTOS SAMPLE LOCATIONxx

12

Pb01

1

LEAD PAINT SAMPLE LOCATIONPbxx

11,16,14

2

13 Pb05 17 18

97

6

4

5

Pb02

3

Pb032223

Pb0424Pb0619

20

21

8

10

16' 8' 0 16'

1

SCALE: 1/16"=1'-0"

AMSA - FAC 00002 FLOOR PLAN

PLAN

NORTH

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\N-D\ENV\TN116\50740.TN116.H101.DWG

8/1/2013 12:02:52 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AS

BE

ST

OS

&

LE

AD

-B

AS

ED

P

AIN

T

SA

MP

LE

LO

CA

TIO

NS

H-101

GF

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.H

101.D

WG

8/1/2013

MT

H

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

GENERAL NOTES

A. A LIMITED PRE-RENOVATION HAZARDOUS MATERIAL SURVEY WAS CONDUCTED

BY LICENSED ASBESTOS INSPECTORS EXPERIENCED IN THE IDENTIFICATION OF

ASBESTOS AND LEAD PAINT BASED ON THE PROVIDED SCOPE OF WORK FOR

PLANNED RESETS AND REPAIRS OF THE FACILITY. THE PURPOSE OF THIS

SURVEY WAS TO IDENTIFY AND QUANTIFY ASBESTOS-CONTAINING MATERIALS

(ACM) AND LEAD BASED PAINT WITHIN AND ON THE EXTERIOR OF THE

STRUCTURES IN THE AREAS OF PLANNED RESETS OR REPAIRS. THE SURVEY

INCLUDED A VISUAL INSPECTION, SAMPLE COLLECTION, AND SUBSEQUENT

LABORATORY ANALYSIS OF SAMPLES OF MATERIALS SUSPECTED TO CONTAIN

ASBESTOS OR LEAD. SAMPLES WERE COLLECTED AT THIS FACILITY. ACM AND

LEAD PAINT WERE FOUND TO BE LOCATED WITHIN THE AREAS OF THE IDENTIFIED

RENOVATIONS AND WILL REQUIRE ABATEMENT AND PROPER DISPOSAL AS PART

OF THIS PROJECT.

LEGEND

3 22

Page 4: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

C

B

A

1 2 3 4 5 6 7 2

D

C

B

A

1

WORK BAYS

100

OFFICE

AMSA

116

OFFICE

OMS

115

BREAK

113

MECH

111

CORR

114

BATT

102

STOR

103

TOOL

104

TOOL

105

WOMEN'S

112

MEN'S

106

LOCKERS

107

MOTOR POOL

108

FLAM STOR

110

FLAM STOR

109

WASH RACK

200

WORK

100A

REMOVE BLACK EXTERIOR ACM WINDOW

GLAZING AND DISPOSE AS ACM.

PLAN

NORTH

REMOVE WHITE EXTERIOR WINDOW

CAULK AND DISPOSE AS ACM.

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\N-D\ENV\TN116\50740.TN116.H102.DWG

8/1/2013 12:02:57 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AB

AT

EM

EN

T P

LA

N

H-102

GF

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.H

102.D

WG

8/1/2013

MT

H

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

16' 8' 0 16'

1

SCALE: 1/16"=1'-0"

AMSA - FAC 00002 FLOOR PLAN

GENERAL NOTES

A. A LIMITED PRE-RENOVATION HAZARDOUS MATERIAL SURVEY WAS CONDUCTED

BY LICENSED ASBESTOS INSPECTORS EXPERIENCED IN THE IDENTIFICATION OF

ASBESTOS AND LEAD PAINT BASED ON THE PROVIDED SCOPE OF WORK FOR

PLANNED RESETS AND REPAIRS OF THE FACILITY. THE PURPOSE OF THIS

SURVEY WAS TO IDENTIFY AND QUANTIFY ASBESTOS-CONTAINING MATERIALS

(ACM) AND LEAD BASED PAINT WITHIN AND ON THE EXTERIOR OF THE

STRUCTURES IN THE AREAS OF PLANNED RESETS OR REPAIRS. THE SURVEY

INCLUDED A VISUAL INSPECTION, SAMPLE COLLECTION, AND SUBSEQUENT

LABORATORY ANALYSIS OF SAMPLES OF MATERIALS SUSPECTED TO CONTAIN

ASBESTOS OR LEAD. SAMPLES WERE COLLECTED AT THIS FACILITY. ACM AND

LEAD PAINT WERE FOUND TO BE LOCATED WITHIN THE AREAS OF THE IDENTIFIED

RENOVATIONS AND WILL REQUIRE ABATEMENT AND PROPER DISPOSAL AS PART

OF THIS PROJECT.

4 22

Page 5: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

ARCHITECTURAL ABBREVIATIONS

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAMA AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION

AB ANCHOR BOLT

AC ASBESTOS CEMENT OR ASPHALTIC

CONCRETE

ACI AMERICAN CONCRETE INSTITUTE

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADDL ADDITIONAL

ADDN ADDITION

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR

ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFS ABOVE FINISHED SLAB

AGA AMERICAN GAS ASSOCIATION

AGC ASSOCIATED GENERAL CONTRACTORS

AHJ AUTHORITY HAVING JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL

CONSTRUCTION

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AMP AMPERE

AMT AMOUNT

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS

INSTITUTE

APA AMERICAN PLYWOOD ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

AR AS REQUIRED

ARCH ARCHITECT

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL

INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING AND

MATERIALS

ATCH ATTACHMENT

AUTO AUTOMATIC

AUX AUXILIARY

AVE AVENUE

AVG AVERAGE

AWI ARCHITECTURAL WOODWORKING

INSTITUTE

AWPA AMERICAN WOOD PRESERVERS'

ASSOCIATION

AWT ACOUSTICAL WALL TREATMENT

BD BOARD

BKG BACKING

BLD BUILD

BLDG BUILDING

BM BEAM OR BENCHMARK

BOT BOTTOM

BRZ BRONZE

BTWN BETWEEN

CB CATCH BASIN OR CORNER BEAD

CBB CEMENTITIOUS (BACKER) BOARD

CC CUBIC CENTIMETER

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS OR

CONTRACT DOCUMENTS

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR

FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR

FURNISHED/OWNER INSTALLED

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY OR CORNER

GUARD

CHEM CHEMICAL

CHFR CHAMFER

CHK CHECK

CI CAST IRON

CIP CAST-IN-PLACE

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT

OR CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

cm² SQUARE CENTIMETER

cm³ CUBIC CENTIMETER

CM CONSTRUCTION MANAGEMENT

CMU CONCRETE MASONRY UNIT

CNR CORNER

CNTR COUNTER

CO CARBON MONOXIDE, CERTIFICATE OF

OCCUPANCY, CLEANOUT, OR

COMPANY

COL COLUMN

COM COMMON

COMB COMBINATION, COMBINED

COMM COMMUNICATION

COMP COMPONENT

CONC CONCRETE

CONC CONCRETE FLOOR

COND CONDENSER OR CONDITION

CONF CONFERENCE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CRS COLD ROLLED STEEL

CSG CASING

CSI CONSTRUCTION

SPECIFICATIONS INSTITUTE

CSK COUNTER SUNK

CSMT CASEMENT

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTG COATING

CTR CENTER CONTOUR

CTRL CONTROL

CTV CABLE TELEVISION

CU COPPER C

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIAG DIAGONAL DIAGRAM

DIAG DIAGRAM DIAGONAL

DIFF DIFFERENCE OR DIFFUSER

DIM DIMENSION

DIR DIRECTION

DISP DISPENSER

DIST DISTANCE

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DR DOOR, DRAIN

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DSGN DESIGN

DWG DRAWING

E EAST

E LABEL CLASS E DOOR

EA EACH

EFF EFFICIENCY

EL ELEVATION

ELEC ELECTRIC

ELEC DR OP ELECTRIC DOOR OPENER

EMER EMERGENCY

EMER SHR EMERGENCY SHOWER

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION

AGENCY

EPO EMERGENCY POWER OFF

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ESC ESCAPE OR ESCUTCHEON

ESMT EASEMENT

ESP ESPECIALLY

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

ETR EXISTING, TO REMAIN

EW EACH WAY

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXP BT EXPANSION BOLT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR

EXTINGUISHER

EXT GR EXTERIOR GRADE

F FAHRENHEIT OR FEMALE

FA FIRE ALARM

FAC FACTOR

FACIL FACILITY

FCO FLOOR CLEAN-OUT

FCTY FACTORY

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR, FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF&E FIXTURES, FURNISHINGS, AND

EQUIPMENT

FH FLAT HEAD OR FLAT HEAD SCREWS

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIG FIGURE

FIL FILLET

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIN WD FINISH WOOD

FIXT FIXTURE

FL FLOORLINE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FO FINISHED OPENING

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB OR FACE OF STUD

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT, OR

FRAME

FREQ FREQUENCY

FRMG FRAMING

FRZ FREEZER

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET OR FOOT

FTG FOOTING

FURG FURRING

FURN FURNISH OR FURNITURE

FUT FUTURE

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERAL OR GENERATOR

GI GALVANIZED IRON

GL GLASS

GSM GALVANIZED SHEET METAL

GT GROUT

GUAR GUARANTEE

GYP GYPSUM

GYP BD GYPSUM BOARD

H HIGH

H PLAM HIGH PRESSURE PLASTIC LAMINATE

HAZ MAT HAZARDOUS MATERIALS

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD DOOR

HDBD HARDBOARD

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HIGH PRESSURE OR HORSEPOWER

HQ HEADQUARTERS

HS HEAT-STRENGTHENED (GLASS) OR

HIGH STRENGTH

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

HVY HEAVY

HW HOT WATER

I INTERSTATE (HIGHWAY) OR MOMENT

OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE DIAMETER, OR

INTERIOR DESIGN

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

JAN JANITOR

J-BOX JUNCTION BOX

KD KILN DRIED OR KNOCKED DOWN

KIT KITCHEN

KPL KICKPLATE

L ANGLE

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LBR LUMBER

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE

LHR LEFT HAND REVERSE LATENT HEAT

RATIO

LIB LIBRARY

LIN LINEAR

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LRG LARGE

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LYR LAYER

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MCB METAL CORNER BEAD

MD DECK

ME MECHANICAL ENGINEER

MEAS MEASURE

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL OR MEDIUM

MEMB MEMBRANE

MEMO MEMORANDUM

MF MILL FINISH

MFD MANUFACTURED

MFG MANUFACTURING

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MGT MANAGEMENT

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM OR MINUTE

MISC MISCELLANEOUS

MIT MITER

MKR MARKER

MLDG MOLDING (MOULDING)

MLWK MILLWORK

MM, mm MILLIMETER

MO MASONRY OPENING OR MOTOR

OPERATED

MOD MODEL, MODIFY OR MODULE

MON MONITOR

MR MOISTURE RESISTANT

MS MACHINE SCREW OR MOP SINK

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MW MICROWAVE

MWP MEMBRANE WATERPROOFING

N NORTH

NA NOT APPLICABLE

NAAMM NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL

MANUFACTURERS

NAT NATURAL

NATL NATIONAL

NC NOISE CRITERIA

NCOMBL NONCOMBUSTIBLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NEUT NEUTRAL

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NR NOISE REDUCTION

NRC NOISE REDUCTION COEFFICIENT

NRP NONREMOVABLE

NS NARROW STILE

NUM NUMERAL

O/O OUT TO OUT

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCC OCCUPY

OCT OCTAGON

OD OUTSIDE DIAMETER OR OUTSIDE

DIMENSION

OF/CI OWNER FURNISHED/CONTRACTOR

INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER

INSTALLED

OH OVERHANG

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

OPT OPTIONAL

OR OPERATING ROOM OR OUTSIDE

RADIUS

ORD ORDINANCE OR OVERFLOW ROOF

DRAIN

ORG ORGANIC

ORIG ORIGINAL

ORN ORNAMENTAL

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINISTRATION

OUT OUTLET

OZ OUNCE

PARA PARAGRAPH

PART PARTIAL

PAT PATTERN

PB PUSHBUTTON

PC PIECE, POLYCARBONATE OR

PORTLAND CEMENT

PCA PORTLAND CEMENT ASSOCIATION

PCCP CONCRETE PAVEMENT

PCD PAPER CUP DISPENSER

PAR PARALLEL OR PARAPET

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PED PEDESTAL

PEN PENETRATE

PEND PENDANT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PHAR PHARMACY

PHOTO PHOTOGRAPH

PHS PHILLIPS HEAD SCREW

PKG PACKAGE

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER OR PLASTIC

PLBG PLUMBING

PLYWD PLYWOOD

PMTL PAINTED METAL

PNEU PNEUMATIC

PNL PANEL

PO POST OFFICE OR PURCHASE ORDER

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PREP PREPARATION

PRESS PRESSURE

PREV PREVIOUS

PRMLD PREMOLDED

PROJ PROJECT

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, OR

PRESSURE TREATED

PTN PARTITION

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QRY QUARRY

QT QUARRY TILE

QTB QUARRY TILE BASE

QTF QUARRY TILE FLOOR

QTR QUARTER

QTY QUANTITY

QUAL QUALITY

R RADIUS OR RISER

RA RETURN AIR

RAD RADIATOR

RB RESILIENT BASE OR RUBBER BASE

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROAD OR ROOF DRAIN

REC RECESSED

RECD RECEIVED

RECPT RECEPTACLE

RECT RECTANGLE

REF REFERENCE OR REFRIGERATOR

REFR REFRACTORY REFRIGERATION

REG REGISTER

REINF REINFORCE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

RET RETURN

REV REVISION

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHR RIGHT HAND REVERSE

RHWS ROUND HEAD WOOD SCREW

RL ROOF LEADER

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RS ROUGH SAWN

RT RIGHT

RV ROOF VENT

RVS REVERSE

SA SUPPLY AIR

SALV SALVAGE

SAMP SAMPLE

SAN SANITARY

SAT SUSPENDED ACOUSTICAL TILE

SATC SUSPENDED ACOUSTICAL TILE

CEILING

SB SPLASH BLOCK

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID

CORE

SCH SCHOOL

SCHED SCHEDULE

SCHEM SCHEMATIC

SCP SCUPPER

SCRN SCREEN

SCWD SOLID CORE OFFICER WOOD DOOR

SD SHOP DRAWINGS, SMOKE DETECTOR,

OR SOAP DISPENSER

SDG SIDING

SECT SECTION

SEG SEGMENT

SEL SELECT

SEP SEPARATE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGD SLIDING GLASS DOOR

SHT SHEET

SHV SHELVING

SIM SIMILAR

SJI STEEL JOIST INSTITUTE

SK SKETCH

SLD WDW HORIZONTAL SLIDING WINDOW

SLDG SLIDING

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

SND INS SOUND INSULATION

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SPLY SUPPLY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SANITARY SEWER

SST STAINLESS STEEL

ST STAIRS OR STREET

STC SOUND TRANSMISSION CLASS

STD STANDARD

STIF STIFFENER

STL LNTL STEEL LINTEL

STL PL STEEL PLATE

STNLS STAINLESS

STOR STORAGE

STRUCT STRUCTURAL

STRUCT STL STRUCTURAL STEEL

SUB SUBSTITUTE

SURF SURFACE

SUSP SUSPEND

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SW SWITCH

SWDR SWING DOOR

SYM SYMBOL

SYS SYSTEM

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL BAR

TCA TILE COUNCIL OF AMERICA

TCP TELEPHONE CONTROL PANEL

TEMPERATURE CONTROL PANEL

TD TOWEL DISPENSER

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPERATURE OR TEMPORARY

THD THREAD

THERM THERMAL

THK THICKNESS

THRES THRESHOLD

THRU THROUGH

THRUOUT THROUGHOUT

TMPD TEMPERED

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TO TOP OF ___

TOW TOP OF WALL

TRANS TRANSOM

TRTD TREATED

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U, u HEAT TRANSFER COEFFICIENT

UC UNDERCUT

UCD UNDERCUT DOOR

UL UNDERWRITERS LABORATORIES

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VAC VACUUM

VAR VARIES

VCT VINYL COMPOSITION TILE VITRIFIED

CLAY TILE

VENT VENTILATION

VERT VERTICAL

VFAT VINYL FACED ACOUSTICAL TILE

VIC VICINITY

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC COMPOUND

VOL VOLUME

VOLT VOLTAGE

W WIDE OR WEST

W/ WITH

W/O WITHOUT

WARR WARRANTY

WBL WOOD BLOCKING

WD WOOD

WDW WINDOW

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

GWB OR MORTAR

METAL

CERAMIC TILE

CONCRETE

GLASS

GWB

BATT INSULATION

PLYWOOD

RIGID INSULATION

ROUGH WOOD

FINISHED WOOD

METAL STUD

IRON/STEEL

CONCRETE

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION,

OR ITEM TO BE DEMOLISHED

NEW CONSTRUCTION

AREA OF EXISTING FINISHES

OR SLAB TO BE DEMOLISHED

WALL AND DOOR SYMBOLS

MATERIALS LEGEND

PLAN & SECTION ELEVATION

REFLECTED CEILING PLAN SYMBOLS

GWB CEILING

MECHANICAL SUPPLY DIFFUSER

MECHANICAL RETURN GRILLE

EXPEXPOSED TO STRUCTURE ABOVE (NO CEILING)

24"x24" ACCESS PANEL

EXISTING WALL TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO REMAIN

LAY-IN ACT

FLUORESCENT STRIPLIGHT

PENDANT TUBE FIXTURE

2X4 FIXTURE

2X2 FIXTURE

1X1 FIXTURE

1X4 FIXTURE

WALL MTD FIXTURE

CEILING MTD FIXTURE

BATTERY PACK W/ NO. OF HEADS AS SHOWN.

REMOTE EMERGENCY HEAD - 'a' INDICATES

BATTERY PACK.

NIGHT LIGHTNL

CLG MTD WALL WASHER

CEILING MTD EXIT SIGN W/ ARROWS AS INDICATED

(80" AFF TO BOTTOM)

WALL MTD EXIT SIGN W/ ARROWS AS INDICATED

(90" AFF)

2X4 LIFE SAFETY FIXTURE

2X2 LIFE SAFETY FIXTURE

1X4 LIFE SAFETY FIXTURE

CEILING MTD FLUOR LIFE SAFETY FIXTURE

EXISTING CAGE REMAIN

ETREXISTING, TO REMAIN

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A001.DWG

8/1/2013 12:03:11 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AR

CH

IT

EC

TU

RA

L A

BB

RE

VIA

TIO

NS

A-001

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

001.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

522

Page 6: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

CONTRACT LIMIT LINE

DEMOLITION LINE

ELEVATION INDICATOR

CENTER LINE INDICATOR

EXISTING TO REMAIN LINE

ETR FIRE RATED RESISTIVE LINE, 2 HOUR

HIDDEN FEATURES LINE

NEW LINE

BREAK, STRAIGHT

(SEE SECTION INDICATORS, BUILDING,

WITH BREAK STANDARDS)

DETAIL INDICATOR

DRAWING BLOCK TITLE, TYPICAL

ELEVATION INDICATOR,

INTERIOR, MULTIPLE VIEW

ELEVATION INDICATOR,

INTERIOR, SINGLE VIEW

ARCHITECTURAL SYMBOLS

CENTER LINE

FIXTURE, FURNITURE

& EQUIPMENT INDICATOR

ROOM NAME AND NUMBER

FEC

CG

22

STRUCTURAL GRID, COLUMN TAG

KEYNOTE

WALL OR PARTITION TYPE

FIRE EXTINGUISHER CABINET

CONTRACTING OFFICER GUARD

NORTH ARROW

DETAIL NUMBER

SHEET WHERE DRAWN

BUILDING SECTION INDICATOR

DETAIL INDICATOR

DESIGN INTENT

A. ELEMENTS THAT APPEAR TO ALIGN ON DRAWINGS ARE INTENDED TO ALIGN AND SHALL BE MADE TO

ALIGN UNLESS OTHERWISE NOTED. DIMENSIONS ARE TO FACE OF FINISH UNLESS NOTED OTHERWISE

(UNO).

B. DIMENSIONS, WHERE SHOWN, ARE DERIVED FROM FIELD MEASUREMENTS OR EXISTING DRAWINGS

APPROVED BY THE GOVERNMENT. ALL EXISTING DIMENSIONS SHALL BE FIELD VERIFIED BY THE

CONTRACTOR. AFTER DEMOLITION AND PRIOR TO INSTALLING NEW WORK, THE CONTRACTOR SHALL

LAYOUT ALL WALL / PARTITION LOCATIONS AND BRING DIMENSIONAL DISCREPANCIES TO THE

ATTENTION OF THE CONTRACTING OFFICER PRIOR TO PLACEMENT OF ANY NEW WORK.

C. ALL MASONRY OPENING DIMENSIONS INDICATED ARE NOMINAL, AND VARY FROM OPENING TO

OPENING. FIELD VERIFY ALL DOOR AND WINDOW REPLACEMENT DIMENSIONS PRIOR TO SHOP

DRAWINGS.

CONTRACTOR RESPONSIBILITIES

D. CONTRACTOR TO VERIFY ALL SCOPE OF WORK REQUIREMENTS PRIOR TO THE START OF WORK. DO

NOT PROCEED WITH ANY WORK NOT LISTED IN THE DESIGN PACKAGE WITHOUT PRIOR APPROVAL

FROM GOVERNMENT. NOTIFY CONTRACTING OFFICER IMMEDIATELY OF ANY UNFORESEEN

CONDITIONS PRIOR TO EXECUTION OF WORK.

E. THIS PROJECT IS A RENOVATION AS SHOWN, INCLUDING DEMOLITION OF EXISTING CONDITIONS AND

REPLACEMENT WITH NEW CONSTRUCTION. ALL ITEMS NOTED TO BE DEMOLISHED OR REMOVED

SHALL BE DISPOSED OF OR RECYCLED AS INSTRUCTED PER THE SPECIFICATIONS. ALL ITEMS NOTED

TO BE SALVAGED FOR REINSTALLATION SHALL BE CAREFULLY REMOVED, STORED, CLEANED,

REINSTALLED, AND REFINISHED AS REQUIRED FOR NEW USE. ALL ITEMS NOTED TO BE RETURNED TO

OWNER SHALL BE COORDINATED WITH THE CONTRACTING OFFICER.

F. THROUGHOUT CONSTRUCTION, CONTRACTOR TO MEET PROVISIONS OF APPLICABLE GOVERNMENT

ENVIRONMENTAL POLLUTION CONTROL LAWS AND ASSOCIATED AGENCY REGULATION.

G. IF CONTRACTOR ENCOUNTERS ASBESTOS-CONTAINING MATERIALS, LEAD-BASED PAINT, OR OTHER

ENVIRONMENTAL HAZARDS DURING THE SCOPE OF WORK INCLUDED IN THIS PROJECT OR AT THIS

FACILITY, THE CONTRACTOR SHALL STOP WORK IMMEDIATELY AND NOTIFY THE CONTRACTING

OFFICER.

H. THE CONTRACTOR SHALL BUILD THE PROJECT, ASSEMBLING THE COMPONENTS WITH CAREFUL

ATTENTION TO MAINTAIN THE INTEGRITY OF THE STRUCTURE AND AS REQUIRED TO CREATE A

COMPLETED PROJECT THAT IS IN COMPLIANCE WITH THE STATED DESIGN INTENT. FURTHERMORE,

THE BUILDING SYSTEMS SHALL BE IN COMPLIANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.

I. CONTRACTOR SHALL COORDINATE THE WORK OF THE VARIOUS SUBCONTRACTORS AND MATERIAL

SUPPLIERS TO ASSURE THE DESIGN INTENT HAS BEEN ACHIEVED.

J. RETAIN NECESSARY FEDERAL, STATE & LOCAL PERMITS AND PERFORM WORK TO COMPLY WITH

APPLICABLE CODES AND ORDINANCES.

K. CONTRACTOR TO COORDINATE ANY PHASING WITH THE CONTRACTING OFFICER, AS REQUIRED. THE

CONSTRUCTION SHALL NOT DISRUPT THE NORMAL FACILITY ACTIVITIES OR ENDANGER ANY OF THE

BUILDING OCCUPANTS.

L. COORDINATE SYSTEM INTERRUPTIONS WITH GOVERNMENT 48-HOURS IN ADVANCE. MINIMIZE NOISE

AND SYSTEMS INTERRUPTIONS AS MUCH AS POSSIBLE. OUTAGES MORE THAN 2 HOURS WILL BE

CONSIDERED UNACCEPTABLE.

M. BRING TO THE ATTENTION OF THE CONTRACTING OFFICER ANY DISCREPANCIES OR OMISSIONS IN

DRAWINGS OR SPECIFICATIONS FOR RESOLUTION.

N. WHERE INCIDENTAL SYSTEMS WORK OR CONTRACTOR'S METHODS REQUIRE WORK BEYOND THE

EXTENTS SHOWN, PROTECT EXISTING FINISH SYSTEMS TO AVOID DAMAGE. REPLACE FINISHES AS

REQUIRED WHERE DAMAGE IS UNAVOIDABLE.

O. WHERE NEW FINISHES ARE SHOWN AT EXISTING CONSTRUCTION, PREPARE EXISTING SUBSTRATES AS

REQUIRED FOR INSTALLATION OF NEW FINISHES.

P. FURNISHINGS & EQUIPMENT ARE NOT INCLUDED IN THE SCOPE OF WORK AND MAY NOT BE INDICATED

ON DRAWINGS, AND WHEN SHOWN, ARE FOR REFERENCE ONLY. COORDINATE REMOVAL AND

REINSTALLATION OF FURNITURE OR EQUIPMENT REQUIRED TO PERFORM ALL WORK WITH THE

CONTRACTING OFFICER PRIOR TO CONSTRUCTION.

Q. WORK HOURS WILL BE LIMITED TO USACE HOURS MONDAY THRU FRIDAY (7AM -5PM). NO WEEKENDS.

R. THE CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES AND PROTECT ALL AREAS OF THE

FACILITY THAT ARE NOT PART OF THIS WORK.

S. COORDINATE LOCATION OF LAY DOWN AREA AND ANY TEMPORARY FACILITIES WITH CONTRACTING

OFFICER AND/OR FACILITY.

T. CONTRACTOR SHALL UTILIZE LOCAL UTILITY COMPANY TO IDENTIFY LOCATION OF EXISTING UTILITIES

AND OBTAIN A DIG PERMIT PRIOR TO ANY EXCAVATION OR WORK OUTSIDE OF BUILDINGS.

FIRE / LIFE SAFETY

U. CONTRACTOR TO COORDINATE WITH CONTRACTING OFFICER TO ENSURE ALL MEANS OF EGRESS AND

FIRE PROTECTION SYSTEMS ARE COORDINATED WITH PHASING PLANS SUCH THAT SYSTEMS ARE

OPERATIONAL IN OCCUPIED AREAS WHILE OTHERS ARE UNDER CONSTRUCTION.

V. ALL EXISTING WALL RATINGS ARE TO BE MAINTAINED. ANY NEW PENETRATIONS OF EXISTING WALLS

SHALL BE PROTECTED IN ACCORDANCE WITH UL REQUIREMENTS. ANY EXISTING UNPROTECTED

PENETRATIONS WHICH ARE EXPOSED IN THE COURSE OF THE WORK SHALL BE SIMILARLY PROTECTED

BY THE CONTRACTOR.

W. ALL FINISHES SHALL BE CLASS 'A' FIRE RATED, UNO.

X. FOR FIRE RATED AND/OR SMOKE PARTITIONS, THE SURFACE AREA OF AN INDIVIDUAL RECESSED

METALLIC OUTLET, SWITCH BOX, ETC. SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATE

SURFACE AREA OF THE RECESSED OUTLETS, BOXES, ETC. SHALL NOT EXCEED 100 SQUARE INCHES

PER 100 SQUARE FEET OF SURFACE WALL AREA. BOXES THAT EXCEED EITHER 16 SQUARE INCHES OR

THE AGGREGATE AREA LIMITATION SHALL BE RECESSED. RECESSED BOXES LOCATED ON OPPOSITE

SIDES OF WALLS OR PARTITIONS, REGARDLESS OF THEIR VERTICAL SEPARATION IN THE WALL, SHALL

BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.

Y. ITEMS WITH A SURFACE AREA GREATER THAN 16 SQUARE INCHES SHALL NOT BE RECESSED IN A FIRE

RATED AND/OR RATED SMOKE WALL.

STRUCTURAL / ARCHITECTURAL

Z. PROVIDE FRAMING SYSTEM AND MEMBERS, LATERAL SUPPORT BRACING, HANGING DEVICES AND

ANCHORS THROUGHOUT THE SPACE AS REQUIRED FOR SAFE SUPPORT OF MATERIALS AND ITEMS AS

INDICATED ON DRAWINGS AND IN COMPLIANCE WITH SEISMIC CODE. FOR PARTITIONS THAT DO NOT

EXTEND TO DECK, PROVIDE BRACING AT4'-0" ON CENTER IN ALTERNATING DIRECTIONS. ATTACH USING

STIFF CLIPS AS REQUIRED.

AA. ALL BLOCKING SHALL BE METAL U.N.O. AS WOOD. PROVIDE FIRE RETARDANT TREATED OR STANDARD

LUMBER COATED WITH AN APPROVED FIRE RETARDANT SEALER FOR CONCEALED WOOD BLOCKING,

NAILERS, SUPPORT FRAMING, ETC.

AB. ALL WALLS AND BULKHEADS SHALL BE BUILT INCORPORATING CONTROL JOINTS AS APPROPRIATE TO

CONTROL MOVEMENT IN THE CEILING AND/OR WALL DUE TO TEMPERATURE VARIATION OVER TIME.

AC. ALL GRILLES AND DIFFUSERS LOCATED ON GYPSUM BOARD SURFACES SHALL BE PAINTED TO MATCH

ADJACENT SURFACE COLOR.

AD. DOOR FRAMES TO BE CAULKED TO FLOOR AT ALL NON-CARPET LOCATIONS.

AE. FOR EXISTING CEILING PATCHING, WHERE CEILING IS CUT OUT OR PORTIONS REMOVED FOR REMOVAL

OF EXISTING OR INSTALLATION OF NEW MECHANICAL, ELECTRICAL AND PLUMBING WORK, DISTURBED

PORTION SHALL BE PATCHED TO MATCH THE EXISTING CEILING FINISH BY THE RESPONSIBLE TRADE.

UNLESS OTHERWISE NOTED, THE ENTIRE CEILING AREA IS TO BE REPAINTED WHERE CEILINGS ARE

GYPSUM BOARD.

AF. WHERE NEW FINISHES ARE APPLIED TO EXISTING SURFACES, THE EXISTING FINISHES SHALL BE

REMOVED AND/OR THE EXISTING SURFACES PREPARED AS REQUIRED TO RECEIVE NEW FINISHES,

UNLESS OTHERWISE NOTED. WHERE REQUIRED TO ACCOMMODATE THE NEW FINISHES, THE

MECHANICAL, PLUMBING AND ELECTRICAL TRADES SHALL DISCONNECT AND REMOVE THEIR

RESPECTIVE DEVICES AND ITEMS FROM THE EXISTING WALL, CEILING AND/OR FLOOR AND RELOCATE

TO THEIR FINAL POSITION IN THE NEW CONSTRUCTION. SUCH DEVICES SHALL INCLUDE BUT NOT BE

LIMITED TO ELECTRICAL SWITCHES, PANELS OUTLETS, MECHANICAL THERMOSTATS, GRILLES,

PLUMBING FIXTURES, MEDICAL GAS OUTLETS, ETC.

AG. WHERE WALL SURFACES ARE PATCHED TO MATCH THE EXISTING, THE NEW FINISH (PAINT, ETC.) SHALL

BE APPLIED TO THE NEAREST CORNER OR BREAK IN THE WALL PLANE, UNLESS NOTED OTHERWISE.

AH. WHERE EXISTING WALLS ARE TO RECEIVE A NEW FINISH, ANY EXISTING PAINTED ITEMS IN OR ON THE

WALL (DOORS, DOOR FRAMES, ELECTRICAL PANELS, ETC.) SHALL BE REPAINTED TO MATCH OR

COORDINATE WITH THE NEW FINISH.

AI. ALL JOINT SEALANT SHALL BE STANDARD COLORS AND MATCH ADJACENT MATERIALS. SEALANTS

SHALL E SUITABLE FOR ADJACENT SURFACES AND LOCATIONS.

AJ. ALL NEW INTERIOR DOORS SHALL BE HOLLOW METAL DOORS AND FRAMES TO MATCH EXISTING.

PROVIDE WELDED FRAMES AT NEW CONSTRUCTION AND KNOCK DOWN FRAMES AT EXISTING

CONSTRUCTION. DOOR HARDWARE SHALL MATCH EXISTING.

AK. MAINTAIN MIN 18" OF CLEARANCE ON LATCH PULL SIDE AND MIN. 12" OF CLEARANCE ON LATCH PUSH

SIDE OF DOORS AS REQUIRED BY CODE.

AL. SINKS ARE TO BE LOCATED A MIN. OF 15" FROM ADJACENT WALLS. TOILETS ARE TO BE 18" FROM

ADJACENT WALL (LOCATED TO CENTERLINE). HINGED SIDE OF DOOR FRAMES TO BE INSTALLED 4"

FROM PERPENDICULAR WALL UNO/

MECHANICAL / PLUMBING / ELECTRICAL

AM. THE CONTRACTOR SHALL PROVIDE CHASES FOR HVAC, PLUMBING, AND ELECTRICAL AS REQUIRED

AND AS NECESSARY. PROVIDE FURR-OUTS, THICKENED WALLS, AND/OR CHASES AS REQUIRED TO

ACCOMMODATE PIPES, VALVES, PANELS AND OTHER SYSTEM ELEMENTS. CONTACT CONTRACTING

OFFICER IN THE EVENT SUCH A FURR-OUT MAY AFFECT FUNCTIONALITY OF SPACE. COORDINATE ALL

CHANGES WITH CONTRACTING OFFICER.

AN. PIPING LOCATED INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES WITH THE

EXCEPTION OF PIPING IN EQUIPMENT/MECHANICAL ROOM. THE CONTRACTOR SHALL COORDINATE

WITH OTHER TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS. THE

CONTRACTOR SHALL GAIN APPROVAL FROM THE CONTRACTING OFFICER PRIOR TO LOCATING AND/OR

PROVIDING "FURRED SPACES" NOT INDICATED ON THE FLOOR PLANS.

AO. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF TYPE SPECIFIED ARE INSTALLED IN WALLS

AND NON-ACCESSIBLE TYPE CEILINGS AND SOFFITS WHERE ACCESS, SERVICE OR ADJUSTMENT TO

HVAC, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS LOCATED IN RATED

ASSEMBLIES SHALL BE THE FIRE RATED TYPE EQUAL TO THE RATING OF THE WALL, SOFFIT OR CEILING

IN WHICH THEY OCCUR. PROVIDE ACCESS PANELS SPECIFICALLY IN GYPSUM BOARD CONSTRUCTION

(WALLS AND CEILINGS) AS REQUIRED TO ACCESS CONCEALED EQUIPMENT, SYSTEMS AND SPACES.

PAINT ACCESS PANELS TO MATCH ADJACENT SURFACE.

AP. HVAC RETURNS, DIFFUSERS, AND ANY OPENINGS MUST BE COVERED OR SEALED DURING DUSTY

OPERATIONS. WHERE WORK AREAS ARE NOT CONTAINED, SWEEP, VACUUM & DUST DOWN AT THE

COMPLETION OF EACH WORK DAY. INSTALL FILTERS IN RETURN GRILLES AFTER MECHANICAL SYSTEM

IS OPERATIONAL.

AQ. ALL GRILLES AND DIFFUSERS LOCATED ON GYPSUM BOARD SURFACES SHALL BE PAINTED TO MATCH

ADJACENT SURFACE COLOR.

GENERAL PROJECT NOTES

FIRE-RATED RESISTIVE,

SMOKE BARRIER LINE, 1 HOUR

FIRE-RATED RESISTIVE BARRIER LINE,

1 HOUR (HAZ.)

SMOKE PARTITION LINE (HAZ.)

A. KEEP THE BUILDING AND SITE WELL ORGANIZED AND CLEAN THROUGHOUT CONSTRUCTION.

B. PROTECT ADJACENT WORK FROM DAMAGE AND DEBRIS ACCUMULATION. PROVIDE GENERAL DAILY

CLEAN-UP AND PICK-UP. REMOVE ALL SCRAP AND DEBRIS FROM THE SITE.

C. EXCEPTION: RE-USABLE SCRAP SHALL BE STORED IN A NEATLY MAINTAINED, SECURE, DESIGNATED

STORAGE AREA, PROTECTED FROM WEATHER AND THEFT.

D. AT COMPLETION OF WORK, REMOVE FROM THE JOB SITE ALL TOOLS AND EQUIPMENT, AND SURPLUS

MATERIALS, SCRAP, AND DEBRIS.

E. COORDINATE WITH CONTRACTING OFFICER FOR CONSTRUCTION LAY-DOWN AND DUMPSTER AREA.

F. CLEAN INSIDE AND OUTSIDE OF GLASS SO THERE ARE NO SPOTS, DIRT, SMUDGES OR STREAKS

REMAINING FROM THE CLEANING PROCESS.

G. SCHEDULE FINAL CLEANING AS APPROVED BY THE CONTRACTING OFFICER TO ENABLE THE

GOVERNMENT TO ACCEPT A CLEAN WORK AREA.

CLEANING/MAINTENANCE DURING CONSTRUCTION

& FINAL CLEANING

A. IN GENERAL, EXISTING RATED WALLS ARE REQUIRED TO EXTEND TO THE UNDERSIDE OF THE DECK OR

STRUCTURE, AND SHALL NOT BE ALTERED WITH NEW CONSTRUCTION OR CEILING REPLACEMENT.

B. CONTRACTOR TO SEAL ALL PENETRATIONS THRU RATED WALLS PER THE U.L. ASSEMBLY REQUIRED FOR

EACH PARTICULAR TYPE OF PENETRATION (PIPE, CONDUIT, DUCT, ETC.) AND WALL CONDITION (GYP. BD/MTL.

STUDS, CONCRETE, ETC.). CONTRACTOR TO PROVIDE DATA SHEETS OF EACH TYPE OF U.L. ASSEMBLY USED.

DATA SHEETS TO BE KEPT ON FILE AT JOBSITE OFFICE DURING CONSTRUCTION FOR THE BUILDING

INSPECTOR'S USE. DATA SHEETS TO BE INCLUDED AS PART OF THE CLOSE-OUT DOCUMENTATION AT THE

END OF THE PROJECT.

C. ALL FIRE AND/OR SMOKE RATED PARTITIONS AND CORRIDOR PARTITIONS SHALL EXTEND FROM THE

FINISHED FLOOR TO WHERE IT MAY BE SEALED TIGHT, SUCH AS THE UNDERSIDE OF THE STRUCTURE OR

DECK ABOVE. ALL PENETRATIONS THROUGH SUCH PARTITIONS SHALL BE SEALED PER THE APPROPRIATE

U.L. DETAIL FOR THE WALL RATING DESIGNATED. COORDINATE PROPER SEALING OF HVAC, PLUMBING AND

ELECTRICAL ITEMS WITH HVAC, PLUMBING AND ELECTRICAL DRAWINGS.

D. ALL CORRIDOR PARTITIONS SHALL BE MADE SMOKE TIGHT. ALL SUCH PARTITIONS SHALL EXTEND FROM THE

FINISHED FLOOR TO THE UNDERSIDE OF THE STRUCTURE OR DECK ABOVE. ALL PARTITIONS AND ANY

PENETRATIONS SHALL BE SEALED TIGHT WITH DRYWALL COMPOUND OR SEALANT. RATED WALLS SHALL BE

SEALED WITH A U.L. LISTED AND APPROVED FIRESTOPPING ASSEMBLY.

E. EXISTING FIRE/SMOKE WALLS WITHIN THE LIMITS OF CONSTRUCTION SHALL BE INSPECTED TO CORRECT

THE FOLLOWING ITEMS:

PARTITION EXTENDS AND IS TIGHT TO, AND SEALED OFF FROM, THE BOTTOM OF THE DECK OR

STRUCTURE ABOVE.

ALL PENETRATIONS AND HOLES THROUGH THE WALLS ARE REPAIRED/PATCHED IN ACCORDANCE WITH

THE APPLICABLE DETAILS.

F. EXISTING PENETRATIONS: EXISTING CONCEALED AREAS SUCH AS CHASES, UNDERSIDE OF FLOORS BELOW

EXISTING TOILET/BATHROOM FACILITIES, BELOW EXISTING EQUIPMENT, ETC., WITHIN THE LIMITS OF

CONSTRUCTION, SHALL BE EXAMINED BY THE CONTRACTOR DURING THE PROCESS OF CONSTRUCTION. ALL

SUCH AREAS HAVING OPEN PENETRATIONS SHALL BE SEALED OFF WITH FIRE RATED MATERIAL AS

REQUIRED. THE CONTRACTOR SHALL NOTE THE EXTENT OF SUCH AREAS AND SHALL VERIFY ALL SUCH

AREAS WITH THE CONTRACTING OFFICER. ANY/ALL ADDITIONAL WORK SHALL BE APPROVED BY THE

CONTRACTING OFFICER BEFORE THE CONTRACTOR PROCEEDS.

G. ANY DEVICE LOCATED IN A FIRE AND/OR SMOKE RATED WALL UP TO 16"X16" IN SIZE SHALL BE PROTECTED

WITH ONE LAYER OF 5/8" RATED GYPSUM BOARD FOR 1 HOUR WALLS. THE DEVICE SHALL BE COMPLETELY

ENCLOSED BY THE GYPSUM BOARD WHICH SHALL BE SCREW ATTACHED TO AUXILIARY DRYWALL FRAMING

AS REQUIRED TO PROVIDE THE PROPER SIZE ENCLOSURE. ELECTRICAL BOXES, NOT OVER 16 SQUARE

INCHES, MAY BE PROTECTED BY AN APPROVED INTUMESCENT PAD IN LIEU OF BEING BOXED IN WITH

GYPSUM WALLBOARD.

H. IN GENERAL, FIRE PROTECTION SYSTEMS INCLUDING SPRINKLERS ARE NOT INCLUDED WITHIN THE SCOPE

AND SPRINKLER HEAD LOCATIONS ARE NOT INDICATED ON THE REFLECTED CEILING PLANS; EXCEPT AS

NOTED BELOW:

IF SPRINKLERS ARE LOCATED WITHIN AREAS OF NEW CEILING WORK, CONTRACTOR SHALL ENSURE THAT

CEILING INSTALLATION IS COMPLETED IN A MANNER TO PROVIDE COMPLETE (100%) AUTOMATIC

SPRINKLER COVERAGE AS DEFINED IN NFPA STANDARD 13 AND IN THE PROJECT MANUAL AND AS

REQUIRED BY THE GOVERNMENT'S INSURANCE UNDERWRITER. CONTRACTOR SHALL PROVIDE DRAWINGS

SHOWING LOCATIONS OF SPRINKLER HEADS FOR APPROVAL.

I. IF ANY EXISTING FIREPROOFING OR FIRE ASSEMBLIES (WHICH ARE TO REMAIN) ARE DAMAGED DURING

DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM TO ORIGINAL FIRE PROTECTION REQUIREMENTS.

INTEGRITY OF EXISTING RATED ROOFS, FLOORS AND WALLS (WHICH ARE TO REMAIN IN PLACE) SHALL BE

MAINTAINED THROUGHOUT ALL PHASES OF CONSTRUCTION. CONTACT THE CONTRACTING OFFICER TO

VERIFY TESTED ASSEMBLIES TO BE USED FOR REPAIRS.

FIRE AND/OR SMOKE WALL/PENETRATIONS

PLAN

NORTH

1

501

ROOM NAME

RM#

1

A500

A201

1

2

3 4

A201

4

2' 0 2' 4'4'

1

1/4"=1'-0"

TITLE

1

501

1

A

WINDOW ELEVATION

GENERAL PROJECT NOTES (CONTINUED)

GENERAL PROJECT DEMOLITION NOTES

A. COORDINATE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL, COMMUNICATIONS AND INFORMATION

SYSTEMS DRAWINGS FOR DEMOLITION OF UTILITIES.

B. THE CONTRACTOR SHALL BRACE EXISTING STRUCTURES AND STRUCTURAL ELEMENTS AS NECESSARY

DURING DEMOLITION.

C. THE CONTRACTOR SHALL NOT CUT STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD

CARRYING CAPACITY OR LOAD/DEFLECTION RATIO. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING

OFFICER OF ALL STRUCTURAL CUTS PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED FROM THE

ARCHITECT AND A STRUCTURAL ENGINEER.

D. THE CONTRACTOR SHALL REPLACE OR REPAIR EXISTING TO REMAIN FINISHES, ETC, WHICH ARE DAMAGED

DURING DEMOLITION (INCLUDING BUT NOT LIMITED TO - CEILING GRID, CEILING TILE, WALL COVERINGS,

FLOOR COVERINGS, CORNER GUARDS, WALL GUARDS, HANDRAILS, CHAIR RAIL, MOLDINGS, ETC.).

E. DURING DEMOLITION, THE CONTRACTOR SHALL TAKE CARE TO MINIMIZE NOISE AND VIBRATION.

CONSTRUCTION SHALL BE ISOLATED.

F. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION DRAWINGS FOR DEMOLITION WORK TO

BE PERFORMED BY OTHER TRADES. AVOID DUPLICATION IN BIDDING. CLOSE COORDINATION IS REQUIRED

BETWEEN ALL DEMOLITION CONTRACTORS SO THAT THE DISPOSITION OF EXISTING CONCEALED UTILITIES,

EXPOSED BY DEMOLITION UNDER THIS SECTION, IS IDENTIFIED SO THAT THE PROGRESS OF THE WORK IS

NOT IMPEDED. ALL HOLES AND OPENINGS IN FLOOR SLABS AS A RESULT OF EXISTING MECHANICAL,

PLUMBING, OR ELECTRICAL UTILITY REMOVAL ARE TO BE FILLED IN WITH CONCRETE FLUSH TO MATCH

EXISTING.

G. ALL CONCRETE, MASONRY, TILE AND PLASTER SURFACES INDICATED TO BE CUT AND PATCHED OR ARE ON A

SURFACE IN WHICH A DOOR, WINDOW, OR PORTION OF THE SURFACE IS TO BE REMOVED, SHALL BE CUT

WITH MASONRY SAWS OR PREPARED FOR CLEAN JOINTS AND PATCHED FLUSH TO RECEIVE NEW MATCHING

MATERIALS AND FINISHES.

H. IN LOCATIONS WHERE EXISTING WALLS OR ELEMENTS WITHIN WALLS ARE REMOVED, PATCH ADJACENT

WALLS AS REQUIRED WITH MATERIALS AND FINISHES TO MATCH EXISTING OR PER THE FINISH SCHEDULE,

UNO.

I. THE GOVERNMENT SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL MATERIAL AND ITEMS TO BE REMOVED.

THE GENERAL CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER WHEN DEMOLITION WORK IN A

CERTAIN AREA IS TO BEGIN, AND CONDUCT A SURVEY WITH THE OWNER OF THAT AREA TO IDENTIFY ITEMS

TO BE SALVAGED. ITEMS IDENTIFIED BY THE CONTRACTING OFFICER TO BE SALVAGED AND TURNED OVER

TO THE OWNER ARE TO BE REMOVED BY THE CONTRACTOR AND DELIVERED TO A MUTUALLY AGREED UPON

LOCATION.

J. CONTRACTOR SHALL BE RESPONSIBLE FOR STEP-OFF MATS AT THE CONSTRUCTION ENTRANCE

THROUGHOUT ENTIRE PROJECT. MATS SHALL BE REPLACED BEFORE ANY DEBRIS IS TRACKED INTO THE

EXISTING CONTRACTING OFFICER.

K. ALL WASTE DISPOSAL ASSOCIATED WITH DEMOLITION AND NEW WORK, CONTRACTOR LAY-DOWN AREAS,

AND CONSTRUCTION ENTRANCES SHALL BE COORDINATED WITH CONTRACTING OFFICER PRIOR TO

CONSTRUCTION.

GENERAL NOTES FOR EXISTING CONCRETE SLAB

REMOVAL AND REPLACEMENT

A. SAW CUT AND REMOVE EXISTING CONCRETE SLAB IN AREAS AS SHOWN. TO THE GREATEST EXTENT

POSSIBLE, MAKE EVERY EFFORT TO MINIMIZE THE AREA OF SLAB TO BE DEMOLISHED.

B. UPON COMPLETION OF PLUMBING/PIPING INSTALLATION, FILL VOIDS IN SUBGRADE WITH FLOWABLE FILL

MATERIAL. FLOWABLE FILL SHALL HAVE A MAXIMUM COMPRESSIVE STRENGTH OF 65 PSI (40 PSI MINIMUM) AT

28 DAYS. CEMENT SHALL BE ASTM C150 TYPE I/II WITH 50 LB/CY, FLY ASH 600 LB/CY (ASTM C 618, TYPE F),

FINE AGGREGATE 2,500 LB/CY (ASTM C33, PEA GRAVEL WITH SAND), WATER CONTENT 500-550 LB/CY (ASTM

C94), AIR ENTRAINMENT 4-7% (ASTM C260). EVAPORATION OF BLEED WATER SHALL NOT RESULT IN

SHRINKAGE OF MORE THAN 1/8 INCH PER FOOT OF FLOWABLE FILL DEPTH. ALLOW FLOWABLE FILL TO CURE

FOR A MINIMUM OF 12 HRS.

C. REPAIR/REPLACE EXISTING VAPOR RETARDER (IF ENCOUNTERED) WITH 6 MIL POLYETHYLENE VAPOR

RETARDER SHEET PER MANUFACTURER'S RECOMMENDATIONS.

D. IN AREAS OF SLAB TO BE PATCHED, CLEAN EXISTING CONCRETE SURFACES TO ACCEPT NEW CONCRETE.

PER MANUFACTURER'S RECOMMENDATIONS, APPLY EPOXY BONDING AGENT (ASTM C881, TYPE V) TO

SURFACES OF EXISTING SLAB WHICH ARE TO BE IN CONTACT WITH NEW CONCRETE.

E. CONCRETE SLAB SHALL MATCH THE THICKNESS OF THE EXISTING SLAB (4" MINIMUM THICKNESS) AND SHALL

SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,500 PSI AT 28 DAYS. PORTLAND CEMENT SHALL

CONFORM TO ASTM C150, WATER/CEMENT RATIO = 0.57, AGGREGATE SHALL BE PER ASTM C33, DEFORMED

STEEL REINFORCEMENT SHALL BE PER ASTM A615 GRADE 60. PROVIDE #4 AT 16" ON CENTER SPACING IN

EACH DIRECTION OF SLAB WITH A MINIMUM CLEAR COVER OF 3/4".

F. FINISH CONCRETE WITH STEEL TROWEL AND MATCH EXISTING CONCRETE FINISH SLAB HEIGHT TO THE

GREATEST EXTENT POSSIBLE.

G. CLEAN AND PREPARE NEW AND EXISTING CONCRETE FOR ACCEPTANCE OF EITHER "THICKSET" OR "THINSET"

TILE APPLICATION, TO BE DETERMINED BASED ON THE EXISTING CONDITIO AND THICKNESS. PROVIDE

LATEX-PORTLAND CEMENT MEDIUM MORTAR BED FOR ALL TILE - EXTRA HEAVY SERVICE RATED PER TCNA.

ALLOW CONCRETE TO CURE TO MEET MORTAR MANUFACTURER RECOMMENDATIONS PRIOR TO

INSTALLATION. PROVIDE WATER-CLEANABLE EPOXY GROUT. COMPLY WITH MATERIAL STANDARDS IN ANSI'S

"SPECIFICATIONS FOR THE INSTALLATION OF CERAMIC TILE" THAT APPLY TO MATERIALS AND METHODS

INDICATED.

PHOTO TAG

SHOWS DIRECTION AND AREA OF PHOTO

H. FINAL CLEANING WILL BE COMPARABLE TO THAT PROVIDED BY

PROFESSIONAL, SKILLED CLEANERS USING COMMERCIAL GRADE CLEANING

MATERIALS. CLEANING MATERIALS WILL BE USED WITH CARE, PER

MANUFACTURER'S RECOMMENDATIONS AND WILL BE COMPATIBLE WITH

BUILDING MATERIALS AND FINISHES. FINAL CLEANING WILL INCLUDE

REMOVAL OF DEBRIS FROM PUBLIC PAVED AREAS ADJACENT TO THE SITE.

I. AFTER CONSTRUCTION IS COMPLETE, THE LAY-DOWN AREA SHALL BE

REPAIRED. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO GRADING, FILL

AND SODDING OF LAY-DOWN AREA TO MATCH EXISTING CONDITIONS.

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A002.DWG

8/1/2013 12:03:18 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

GE

NE

RA

L N

OT

ES

A-002

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

002.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

622

Page 7: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

1 2 3 4 5 6 7 2

D

C

B

A

1

WORK BAYS

100

AMSA OFFICE

116

OMS OFFICE

115

BREAK

113

MECH

111

CORR

114

BATT

102

STOR

103

TOOL

104

TOOL

105

WOMEN'S

112

MEN'S

106

LOCKERS

107

MOTOR POOL

108

FLAM STOR

110

FLAM STOR

109

WASH RACK

200

WORK

100A

1 2 3 4 5 6 7 2

D

C

B

A

1

WORK BAYS

100

AMSA OFFICE

116

OMS OFFICE

115

BREAK

113

MECH

111

CORR

114

BATT

102

STOR

103

TOOL

104

TOOL

105

WOMEN'S

112

MEN'S

106

LOCKERS

107

MOTOR POOL

108

FLAM STOR

110

FLAM STOR

109

WASH RACK

200

WORK

100A

#

1. DEMOLISH WINDOW AND ASSOCIATED FASTENERS COMPLETE, AND PREPARE

OPENING FOR NEW WINDOW.

2. DEMOLISH DOOR AND FRAME COMPLETE. COORDINATE DEMOLITION AND

INSTALLATION WITH EXISTING SECURITY SYSTEM. PROTECT EXISTING SECURITY

SYSTEM.

3. DEMOLISH PLUMBING FIXTURES, TOILET ACCESSORIES, WALLS, AND ASSOCIATED

FLOOR AND WALL FINISHES AS SHOWN (INCLUDING TILE MORTAR BED).

COORDINATE WITH NEW WORK PLANS FOR EXTENT OF DEMOLITION, AND

PREPARE SURFACES FOR NEW FINISHES, AS REQUIRED. RETURN FIXTURES AND

TOILET ACCESSORIES TO GOVERNMENT.

4. DEMOLISH CEILING AND ASSOCIATED FRAMING & FASTENERS COMPLETE.

5. HATCHED AREA DENOTES AREA TO DEMOLISH CONCRETE SLAB AS REQUIRED

FOR INSTALLATION OF NEW PLUMBING AND NEW TILE. PROTECT EXISTING FLOOR

DRAIN, AS REQUIRED. SEE SLAB REPLACEMENT NOTES ON A-002 AND TILE

DETAILS.

6. REMOVE EXISTING LOCKERS AND RETURN TO GOVERNMENT.

7. DEMOLISH WINDOW AND ASSOCIATED FASTENERS COMPLETE, AND PREPARE

OPENING FOR NEW WINDOW. DEMOLISH SILL FLASHING AND 8" (3 COURSES) OF

BRICK SILL BELOW WINDOW. DO NOT ALTER BELOW WINDOWS. DO NOT ALTER

EXISTING STRUCTURAL COLUMNS OR TEES TO REMAIN.

8. DEMOLISH EXISTING MASONRY WALL AND PREP SURFACES FOR NEW FINISHES.

9. HEATER ABOVE TO BE REMOVED, STORED AND REINSTALLED IN NEW LOCATION.

GENERAL DEMOLITION NOTES

A. MEN'S 106, LOCKER 107 AND WOMEN'S 112 CONTAINS HARD CEILINGS, CONCRETE

MASONRY WALL CONSTRUCTION AND TILED FLOOR AND BASE. SCOPE OF WORK

INCLUDES REMOVAL OF HARD CEILINGS AND WALLS AS NOTED TO BE

DEMOLISHED. REMOVE TILE FLOOR, BASE, GROUT AND SETTING BED; PREPARE

FOR NEW TILE. PLUMBING FIXTURES, TOILET PARTITIONS, TOILET ACCESSORIES

AND LOCKERS SHALL BE REMOVED AND RETURNED TO GOVERNMENT. ALL

REMAINING MASONRY CONSTRUCTION SHALL BE PREPARED TO RECEIVE NEW

FINISHES. ACOUSTICAL CEILING TILE AND GRID SHALL BE DEMOLISHED. ALL

EXISTING EXTERIOR WINDOWS AND MAIN ENTRY SHALL BE DEMOLISHED.

INTERIOR WINDOWS SHALL NOT BE REPLACED.

B. SEE A-001, A-002, & SPECIFICATIONS FOR ARCHITECTURAL ABBREVIATIONS,

SYMBOLS, & ADDITIONAL GENERAL PROJECT & DEMOLITION NOTES.

C. REFER TO ELECTRICAL & PLUMBING DEMOLITION PLANS FOR ADDITIONAL SCOPE

OF WORK.

DEMOLITION KEY NOTES

1 1 1

7TYP

2

PLAN

NORTH

08' 4' 8'

1

1/8"=1'-0"

AMSA - FAC 00002

DEMOLITION PLAN

4

EXISTING

TRENCH

DRAIN, TYP.

EXISTING

TRENCH

DRAIN, TYP.

CAGE

DIVIDER

CAGE, TYP

OPEN

STORAGE

ABOVE

2

AD101

7 7

WOMEN'S

112

MEN'S

106

LOCKERS

107

PLAN

NORTH

2' 0 2' 4'4'

2

1/4"=1'-0"

AMSA - FAC 00002

ENLARGED DEMOLITION PLAN

6

8

3 4

8

8

8

FD

FD

9

5

5

3 4

6

8

5

1'-2"

5'-1

3

/4

"

FV

1'-1

3

/4

"

FV

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.AD101.DWG

8/1/2013 12:03:25 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AM

SA

- F

AC

00

00

2

DE

MO

LIT

IO

N P

LA

N

AD101

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

D101.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

722

Page 8: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

PATCH & REPAIR EXTERIOR STUCCO CEILING

AS REQUIRED

PLAN

NORTH

32' 16' 0 32'

11

1/32"=1'-0"

AMSA - FAC 00002

KEYPLAN - PHOTOGRAPH LOCATION

DEMOLITION PHOTO

1

EXISTING CONDITIONS @ ENTRANCE/DOOR "A"

DEMOLITION PHOTO

2

EXISTING CONDITIONS @ WINDOW "B"

DEMOLITION PHOTO

3

DEMOLITION PHOTO

4

EXISTING CONDITIONS @ WINDOW "B" EXISTING CONDITIONS @ WINDOW "B"

DEMOLITION PHOTO

5

EXISTING CONDITIONS @ WINDOW "C"

DEMOLITION PHOTO

6

EXISTING CONDITIONS @ WINDOW "D" - OVERALL

DEMOLITION PHOTO

7

DEMOLITION PHOTO

8

EXISTING CONDITIONS @ WINDOW "D" - BRICK HEAD CONDITION EXISTING CONDITIONS @ WINDOW "D" - METAL PANEL HEAD CONDITION

DEMOLITION PHOTO

9

DEMOLITION PHOTO

10

EXISTING CONDITIONS @ WINDOW "D" - SILL CONDITION EXISTING CONDITIONS @ WINDOW "D" - TRANSITION HEAD CONDITION

PROVIDE CONTINUOUS SEALANT AROUND NEW FRAME

PROTECT EXISTING METAL PANEL FLASHING;

PAINT TO MATCH EXISTING METAL PANELS &

PROVIDE SEALANT ALONG ENTIRE VERTICAL JOINT

TO ROOF

PROVIDE SEALANT AT ENTIRE PERIMETER OF NEW

WINDOW FRAME; SEE WINDOW DETAILS

EXISTING PANEL FLASHING TO REMAIN; NEW SILL

PAN HEM TO LAP OVER PANELS BELOW

EXISTING PANEL BASE/HEAD FLASHING TO REMAIN

PREP & PAINT EXISTING STEEL LINTEL;

SEE GENERAL NOTES FOR WINDOWS

REMOVE & REINSTALL EXISTING DOWNSPOUTS AS

REQUIRED, TYP

PREP & PAINT EXISTING STEEL LINTEL;

SEE GENERAL NOTES FOR WINDOWS

EXISTING METAL SILL AND BRICK BELOW TO BE REPLACED;

SEE FLASHING DETAILS FOR ENTIRE WINDOW

PREP & PAINT EXISTING STEEL "TEE COLUMN";

SEE WINDOW DETAILS

PREP & PAINT EXISTING

STEEL LINTELS; SEE

GENERAL NOTES FOR

WINDOWS

PROVIDE CONTINUOUS SEALANT AT ENTIRE WINDOW FRAME

AND AT VERTICAL JOINT BETWEEN NEW FLASHING & EXISTING

METAL PANELS

PROVIDE COPPER STEP FLASHING OVER 8" WIDTH OF BRICK; SECURE WITH LEAD

WEDGE AT FIRST BRICK JOINT UNDER ROOF FLASHING AND WRAP JAMB SECURE

TO METAL PANELS WITH HIGH DOMED GASKETED FASTENERS

PREP & PAINT EXISTING STEEL LINTEL

TO MATCH CEILING; SEE GENERAL NOTES

EXISTING METAL PANELS TO REMAIN, TO

EXTENT POSSIBLE IF REQUIRED, REMOVE AND

REINSTALL, INCLUDING NEW SEALANT AT HEAD

FOR INSTALLATION OF NEW WINDOWS.

DEMOLISH EXISTING METAL SILL AND 8" OF BRICK (3 COURSES)

FOR NEW THROUGH WALL FLASHING; SEE WINDOW DETAILS

LOCATION OF NEW STEP FLASHING AT WINDOW SILL/JAMB

(TYPICAL AT EACH END JAMB); SEE WINDOW DETAILS

LOCATION OF NEW STEP FLASHING AT WINDOW SILL/JAMB

(TYPICAL AT EACH END JAMB); SEE WINDOW DETAILS

AMSA WASH

RACK

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.AD901.DWG

8/1/2013 12:03:38 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

DE

MO

LIT

IO

N P

HO

TO

S

AD901

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

D901.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

822

Page 9: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

1 2 3 4 5 6 7 2

D

C

B

A

1

WORK BAYS

100

AMSA OFFICE

116

OMS OFFICE

115

BREAK

113

MECH

111

CORR

114

BATT

102

STOR

103

TOOL

104

TOOL

105

WOMEN'S

112

MEN'S

106

LOCKERS

107

MOTOR POOL

108

FLAM STOR

110

FLAM STOR

109

WASH RACK

200

WORK

100A

#

1. FIXED WINDOW IN EXISTING OPENING. FIELD VERIFY ROUGH OPENING AS

REQUIRED.

2. SERIES OF OPERABLE WINDOW SIN EXISTING OPENING. FIELD VERIFY ROUGH

OPENING AS REQUIRED. REPLACE BRICK TO MATCH EXISTING. COORDINATE WITH

NEW WINDOW SILL DETAILS & INSTALLATION OF WINDOW & FLASHING.

3. STOREFRONT ENTRANCE AND DOOR. VERIFY AND COORDINATE WITH EXISTING

SECURITY SYSTEM. PROVIDE COMPLETE, FULLY FUNCTIONAL AND INTEGRATED

DOOR SECURITY AND ACCESS CONTROL SYSTEM AT STOREFRONT ENTRANCE

REPLACEMENT.

4. PROVIDE (4) 1'-3" W x 1'-0" D x 6'-0" H IN WOMEN'S 112 AS SHOWN. INSTALL NEW

CONCRETE BASE. SEE DETAIL 5/A401.

5. PROVIDE (16) 1'-3" W x 1'-6" D x 6'-0" IN LOCKER'S 107 AS SHOWN. INSTALL ON

EXISTING BASE.

6. WHERE EXISTING MASONRY WALL WAS REMOVED, PATCH REMAINING MASONRY

WALL AS REQUIRED TO RECEIVE NEW FINISHES.

7. HATCHED AREA DENOTES AREA OF NEW CONCRETE SLAB. REFER TO FLOORING

DETAILS.

8. PAINT EXISTING DOOR AND FRAME TO MATCH EXISTING.

KEY NOTES

GENERAL NOTES

A. SCOPE OF WORK IN MEN'S 106, LOCKERS 107 AND WOMEN'S 112 INCLUDES

INSTALLATION OF NEW GYPSUM BOARD CEILING, NEW WALLS AS SHOWN, NEW

CONCRETE SLAB, NEW FLOOR TILE AND BASE, NEW PLUMBING FIXTURES, LOCKERS,

AND TOILET PARTITIONS AND ACCESSORIES. SPACES AS NOTED SHALL RECEIVE

NEW FINISHES. REFER TO ENLARGED PLAN AND SCHEDULE FOR LOCATIONS.

SCOPE OF WORK IN BREAK 113 INCLUDES REPLACEMENT OF ACOUSTICAL CEILING

TILE AND GRID. ALL EXTERIOR WINDOWS AND MAIN ENTRY SHALL ALSO BE

REPLACED.

B. EXISTING TO REMAIN ARE SHOWN AS "SCREENED" ON THE FLOOR PLANS. NEW

CONSTRUCTION IS INDICATED BY SOLID LINES. REFER TO DEMOLITION DRAWINGS

FOR EXTENT OF EXISTING TO BE REMOVED.

C. WHERE INDICATED ON THE FLOOR PLAN , FURR-OUT RATED WALL WITH 5/8" TYPE

"X" GYPSUM BOARD ON 3-5/8" METAL STUDS AT 16" O.C. MAXIMUM UP TO 4" ABOVE

THE FINISH CEILING IN ORDER TO PROVIDE FOR RECESSED ITEMS IN THE WALL

WITHOUT INTERFERING WITH THE INTEGRITY OF THE RATED WALL.

D. COORDINATE LAYOUT OF FURNITURE AND EQUIPMENT WITH COR. FURNITURE AND

EQUIPMENT SHOWN FOR REFERENCE ONLY.

E. SEE A-401 FOR WALL TYPES.

F. SEE A-501 FOR WINDOW ELEVATIONS & DETAILS.

G. MEN'S 100, WOMEN'S 112 & LOCKERS 107 SHALL RECEIVE NEW FLOOR TILE PER

TCNA #F13207.

PLAN

NORTH

08' 4' 8'

1

1/8"=1'-0"

AMSA - FAC 00002 FLOOR PLAN

EXISTING

BOLLARDS, TYP

EXISTING TRENCH

DRAIN, TYP

EXISTING

TRENCH DRAIN,

TYP

113 BREAK ACT-1ACT----CONC

112 WOMEN'S C-PNT-1GWBPNT-1EX. CMUWT-1WT-1PNT-1

WT-1VARPT-1CONC

107 LOCKER 8'-0" FVC-PNT-1EX. GWBPNT-1EX. CMUPNT-1EX. CMUPNT-1PNT-1

EX. CMUWT-1VARPT-1CONC

106 MEN'S CEILING HEIGHT TO MATCH EXISTING8'-0" FVC-PNT-1GWBPNT-1WT-1EX. CMUWT-1

CBB

PNT-1/ WT-1WT-1VARPT-1CONC

COL FINFINFINFIN

MATMATMATMATMATMAT

BASE

FLOOR

HEIGHTCOL

WEST WALLEAST WALLNORTH WALL SOUTH WALL CEILING

REMARKSROOM NAME

NO.

ROOM

ROOM FINISH SCHEDULE

CAGE

DIVIDER

CAGE, TYP

1

3

1

2

1

A401

ACT ACOUSTICAL TILE

CMU CONCRETE MASONRY UNIT

C-PNT CEILING PAINT

CONC CONCRETE

CS CLEAR SEALER

CBB CEMENTITIOUS BACKER BOARD

GWB GYPSUM WALL BOARD

EX EXISTING

PNT PAINT

PT PORCELAIN TILE

SL SEALANT

SS SOLID SURFACE

TP TOILET PARTITION

UP URINAL PARTITION

VAR VARIES

WT WALL TILE

ROOM FINISH SCHEDULE ABBREVIATIONS

CEILING HEIGHT TO MATCH EXISTING

CEILING HEIGHT TO MATCH EXISTING8'-0" FV

CEILING HEIGHT TO MATCH EXISTING

- - - - - - -

B B C

A

D

ROOM FINISHES

FINMAT

114

GWB/CBB

EX CMU

EX. CMU

EX. CMU

CBB

CBB

GENERAL FINISH NOTES

OPEN

STORAGE

ABOVE

WOMEN'S

112

MEN'S

106

LOCKERS

107

PLAN

NORTH

2' 0 2' 4'4'

2

1/4"=1'-0"

AMSA - FAC 00002

ENLARGED FINISH PLAN

FD

FD

8'-0" FV

4

5

7

WT

-1

PNT-1

PN

T-1

PNT-1

PN

T-1

PNT-1

PN

T-1

PNT-1

PN

T-1

PNT-1

PN

T-1

WT-1

WT

-1

WT-1

WT-1

WT

-1

6

2

A101

EXISTING SLAB

NEW SLAB

ACT-1

MANUFACTURER: USG CORPORATION

SERIES: 2110

COLOR: WHITE RADAR

SIZE: '2x2'x5/8"

C-PNT-1 (EPOXY)

MANUFACTURER: SHERWIN WILLIAMS,

COLOR: SW7007 CEILING BRIGHT WHITE

PNT-1 (EPOXY)

MANUFACTURER: SHERWIN WILLIAMS

COLOR: SW 7547 SANDBAR

FINISH: SATIN

PT-1

MANUFACTURER: DALTILE

SERIES: KEYSTONES

COLOR: URBAN PUTTY SPECKLE

SIZE: 2"x2"

GROUT & SEALANT

MANUFACTURER: LATICRETE

COLOR: ANTIQUE WHITE

WT-1

MANUFACTURER: DALTILE

SERIES: MATTE

COLOR: URBAN PUTTY

SIZE: 6"x6"

FINISH: MATTE

GROUT & SEALANT

MANUFACTURER: LATICRETE

COLOR: ANTIQUE WHITE

TP-1/UP-1

MANUFACTURER: BRADLEY PARTITION

SERIES: SOLID PHENOLIC

COLOR: ALMOND 0920

SS-1 @ WINDOWS

MANUFACTURER: GIBRALTAR

COLOR: 9032 ML ARABIAN MELANGE

SIZE: (2) LAYERS OF 1/2" THICK SOLID

SURFACE TOTALING 1" THICKNESS.

SL-1 @ WINDOWS

MANUFACTURER:

COLOR: TO MATCH MEDIUM BRONZE

OF WINDOWS

A. REFER TO TILE DETAILS FOR FLOOR/WALL TRANSITIONS AND

CONDITIONS.

B. ALL SEALANTS AT TILE EXPANSION JOINTS SHALL MATCH

GROUT.

2

A401

7

6

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A101.DWG

8/1/2013 12:03:45 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AM

SA

- F

AC

00

00

2

FL

OO

R P

LA

N

A-101

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

101.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

8

8

922

Page 10: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

AP

HEAT

C

B

A

1 2 3 4 5 6 7 2

D

C

B

A

1

WORK BAYS

100

AMSA OFFICE

116 OMS OFFICE

115

BREAK

113

MECH

111

CORR

114

BATT

102

STOR

103

TOOL

104

TOOL

105

WOMEN

112

MEN

106

LOCKERS

107

MOTOR POOL

108

FLAM STOR

110

FLAM STOR

109

WASH RACK

200

REFLECTED CEILING PLAN GENERAL NOTES

A. SEE A-002 AND SPECIFICATIONS FOR ADDITIONAL GENERAL PROJECT NOTES.

B. SEE A-131 FOR CEILING DETAILS.

C. SEE THE ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION AND

NOTES WITHIN THE SCOPE OF WORK.

D. REFLECTED CEILING PLANS ARE PROVIDED TO INDICATE AND COORDINATE

REPLACEMENT ARCHITECTURAL CEILINGS AND ELECTRICAL LIGHTING ONLY -

OTHER CEILING MOUNTED ITEMS ARE NOT IN SCOPE; HOWEVER, CONTRACTOR

SHALL BE RESPONSIBLE FOR COORDINATING TEMPORARY MEASURES AND

REINSTALLATION OF ALL CEILING MOUNTED DEVICES AND APPURTENANCES,

INCLUDING BUT NOT LIMITED TO, MECHANICAL DIFFUSERS, GRILLES, SPEAKERS,

ACCESS PANELS, OR FIRE PROTECTION ITEMS.

E. CONTRACTOR SHALL EXERCISE DUE DILIGENCE WHEN REINSTALLING CEILING

MOUNTED DEVICES AND WILL BE RESPONSIBLE FOR REPLACING ANY DAMAGED

ITEMS, IN KIND.

F. ALL SUSPENDED ACOUSTICAL TILE CEILINGS SHALL BE ACT-1 AND MATCH

EXISTING CEILING HEIGHTS, UNO. SEE FINISH SCHEDULE

08' 4' 8'

1

1/8"=1'-0"

AMSA - FAC 00002

REFLECTED CEILING PLAN

3

3

3

3

2

EXP

33

1

2

1. SUSPENDED ACOUSTICAL CEILING TILE & GRID. MATCH EXISTING HEIGHT, UNO.

2. GYPSUM BOARD CEILING. MATCH EXISTING HEIGHT, UNO.

3. EXISTING GYPSUM BOARD CEILING TO REMAIN. PATCH, REPAIR, AND PAINT TO

MATCH EXISTING AS REQUIRED.

4. EXISTING SURFACE MOUNTED HEATER TO BE REINSTALLED IN NEW LOCATION

INDICATED.

5. ACCESS PANEL. SEE A-131 FOR ADDITIONAL DETAILS.

REFLECTED CEILING PLAN KEY NOTES

#

EXP

EXP

EXP

EXP

EXP

2

4

PLAN

NORTH

5

EXPEXP

EDGE OF

CEILING

CONC

EXP

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A121.DWG

8/1/2013 12:03:51 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AM

SA

- F

AC

00

00

2

RE

FLE

CT

ED

C

EILIN

G P

LA

N

A-121

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

121.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

1022

Page 11: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

MAIN RUNNER

CROSS RUNNER

HANGER WIRE

NOTE: SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED

WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVETS,

SCREWS, PINS, PLATES, WITH BENT TABS, OR OTHER APPROVED

CONNECTORS. DESIGN CONNECTORS FOR 2 TIMES THE DESIGN LOAD OR

ULTIMATE AXIAL TENSION OR COMPRESSION (MINIMUM 60 POUNDS)

CROSS RUNNER

LAY-IN TYPE LIGHT

FIXTURE

#12 GA. WIRES TO GRID WITHIN 3" OF EACH

CORNER OF EACH FIXTURE (TANDEM FIXTURES

MAY UTILIZE COMMON WIRES); SEE ASTM FOR

NUMBER OF WIRE REQUIREMENTS

ATTACHED TO CEILING

SYSTEM MAIN RUNNER

MECHANICAL DIFFUSER OR

CEILING SERVICE DEVICE

MAIN RUNNER

CROSS RUNNER

UP TO 56 LBS., PROVIDE MIN (2) #12 GAUGE ADDITIONAL

HANGER WIRES ATTACHED TO DEVICE'S HOUSING AT

OPPOSITE CORNERS. THESE WIRES SHALL CONNECT TO

CEILING SYSTEM HANGER WIRES OR STRUCTURE ABOVE.

WIRES MAY HAVE SLACK. (INSTALLATION OF THESE WIRES

TO BE RESPONSIBILITY OF FIXTURE INSTALLER)

NOT TO SCALE

CEILING TEE DETAIL

D

NOT TO SCALE

LIGHT FIXTURE

SUPPORT DETAIL

B

NOT TO SCALE

MECHANICAL DIFFUSER OR

CEILING SERVICES DETAIL

C

CEILING SUSPENSION SYSTEM NOTES

SCOPE OF SUSPENSION SYSTEM COMPONENTS:

A. SEE ASTM E580/E580M FOR THE STANDARD PRACTICE AND DETAILED

REQUIREMENTS FOR THE INSTALLATION OF CEILING SUSPENSION SYSTEMS

FOR ACOUSTICAL TILE AND LAY-IN PANELS IN AREAS SUBJECT TO EARTHQUAKE

GROUND MOTION, PER THE BUILDING'S SEISMIC DESIGN CATEGORY.

B. CEILINGS LESS THAN OR EQUAL TO 144 SF AND SURROUNDED BY WALLS

CONNECTED TO STRUCTURE ABOVE ARE EXEMPT FROM ASTM E580/E580M.

C. CEILING AREAS 1,000 SF OR LESS ARE EXEMPT FROM LATERAL FORCE BRACING

REQUIREMENTS IN ASTM E580/E580M SECTION 5.2.

D. ONLY HEAVY-DUTY MAIN TEES SHALL BE USED, AS DEFINED IN SPECIFICATION

C635.

E. THE MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING SYSTEM AND THEIR

SPLICES, INTERSECTIONS CONNECTORS, AND EXPANSION DEVICES SHALL BE

DESIGNED AND CONSTRUCTED TO CARRY A MEAN ULTIMATE TEST LOAD OF

NOT LESS THAN 180 LBS IN COMPRESSION AND IN TENSION.

SYSTEM COMPONENTS:

F. UNLESS PERIMETER MEMBERS ARE A STRUCTURAL PART OF AN APPROVED

SYSTEM AND MEET THE STRUCTURAL LOAD CARRYING REQUIREMENTS, WALL

ANGLES OR CHANNELS SHALL BE CONSIDERED AS AESTHETIC CLOSERS AND

SHALL HAVE NO STRUCTURAL VALUE ASSESSED TO THEMSELVES OR METHOD

OF ATTACHMENT TO THE WALLS.

G. PERIMETER SUPPORT ANGLE SHALL SUPPLY A SUPPORT LEDGE OF NOT LESS

THAN 2 INCHES, UNLESS AN APPROVED GRID RETAINAGE CLIP IS USED TO

MAINTAIN CONNECTION OF THE GRID SYSTEM TO THE WALL MOULDING.

H. MAIN RUNNER AND/OR CROSS RUNNER ENDS SHALL BE ATTACHED TO THE

PERIMETER ON TWO ADJACENT WALLS, AND A CLEARANCE OF 3/4" SHALL BE

MAINTAINED BETWEEN THE MAIN RUNNER AND CROSS RUNNER ENDS AND THE

PERIMETER MEMBERS ON THE TWO OPPOSITE WALLS.

I. THE TERMINAL END OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE

SUPPORTED INDEPENDENTLY, A MAXIMUM OF 8 IN FROM EACH WALL OR

CEILING DISCONTINUITY WITH NO. 12 GAUGE WIRE OR APPROVED WALL

SUPPORT (SEE ASTM FIGURE 4).

J. DIRECT CONCEALED SUSPENDED CEILING SYSTEMS SHALL HAVE POSITIVELY

CONNECTED STABILIZER BARS OR MECHANICALLY CONNECTED CROSS

RUNNERS AT A MAXIMUM SPACING OF 60 IN. PERPENDICULAR TO THE MAIN

RUNNERS. STABILIZATION SHALL OCCUR WITHIN 24" OF EACH WALL.

K. THE TERMINAL END OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE

SUPPORTED INDEPENDENTLY, A MAXIMUM OF 8" FROM EACH WALL OR CEILING

DISCONTINUITY WITH NO. 12-GA WIRE OR APPROVED WALL SUPPORTS

(AUTHORITIES HAVING JURISDICTION MUST APPROVE USG AC-M7 SEISMIC

CLIPS OR OTHER MANUFACTURER'S TESTED CLIPS).

SUSPENSION WIRE APPLICATION:

L. SUSPENSION WIRES OF GALVANIZED, SOFT-ANNEALED, MILD WIRE SHALL NOT

BE SMALLER THAN NO. 12 GAUGE SPACED AT 4'-0" ON CENTER ALONG EACH

MAIN RUNNER, UNLESS CALCULATIONS JUSTIFYING THE INCREASED SPACING

OR ALTERNATE MATERIALS ARE PROVIDED.

M. EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION

MEMBER AND TO THE SUPPORT ABOVE, AND EACH WIRE MUST BE WRAPPED

AROUND ITSELF A MINIMUM OF THREE (3) FULL TURNS WITHIN A 3" LENGTH.

CONNECTION DEVICES TO THE SUPPORTING CONSTRUCTION SHALL BE

CAPABLE OF CARRYING NOT LESS THAN 90 LB ALLOWABLE LOAD.

N. SUSPENSION WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT OF PLUMB

UNLESS COUNTERSLOPING WIRES ARE PROVIDED.

O. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING EQUIPMENT A

TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE CONSTRUCTIONS

PRECLUDE DIRECT SUSPENSION.

LATERAL FORCE BRACING:

P. HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR (4) NO. 12 GA WIRES

SECURED TO THE MAIN RUNNER WITHIN TWO (2) INCHES OF THE CROSS

RUNNER INTERSECTION AND SPLAYED NINETY (90) DEGREES FROM EACH

OTHER AT AN ANGLE NOT EXCEEDING FORTY-FIVE (45) DEGREES FROM THE

PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER AT THE

LOCATION OF THE BRACING WIRES SHALL BE EXTENDED TO AND FASTENED TO

THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE

STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED

BY THE BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL

BE PLACED TWELVE (12) FEET ON CENTER IN BOTH DIRECTIONS WITH THE

FIRST POINT WITHIN SIX (6) FEET FROM EACH WALL.

Q. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF SIX (6)

INCHES FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT PROVIDED

WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES.

R. RIGID BRACES THAT HAVE BEEN DESIGNED TO LIMIT RELATIVE LATERAL

DEFLECTIONS AT THE POINT OF ATTACHMENT OF THE CEILING GRID TO LESS

THAN 0.25 INCHES ARE PERMITTED TO BE USED IN THE PLACE OF DIAGONAL

SPLAY WIRES.

LIGHT FIXTURE APPLICATION:

S. ALL LIGHTING FIXTURES SHALL BE ATTACHED TO THE SUSPENDED CEILING

SYSTEM BY MECHANICAL MEANS AS SPECIFIED IN THE NATIONAL ELECTRICAL

CODE, UNLESS INDEPENDENTLY SUPPORTED. A MINIMUM OF TWO (2)

ATTACHMENT DEVICES ARE REQUIRED FOR EACH FIXTURE. SEE DETAILS &

ASTM E580 DIAGRAMS FOR SUPPLEMENTAL HANGER WIRE REQUIREMENTS.

T. LIGHTING FIXTURES WEIGHING LESS THAN 10 LB SHALL HAVE ONE NO. 12 GA

SAFETY WIRE CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE

ABOVE.

U. LIGHTING FIXTURES WEIGHING GREATER THAN 10 LB. BUT LESS THAN 56 LB.

SHALL HAVE, IN ADDITION TO THE GENERAL CONNECTION REQUIREMENTS,

TWO NO. 12 GA HANGAR WIRES CONNECTED FROM THE FIXTURE HOUSING TO

THE STRUCTURE ABOVE THAT ACT AS SAFETY WIRES. IT IS NOT NECESSARY

FOR SAFETY WIRES TO BE TAUT.

V. LIGHTING FIXTURES WEIGHING 56 LB. OR MORE SHALL BE SUPPORTED

DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS.

W. RIGID CONDUIT SHALL NOT BE USED FOR THE ATTACHMENT OF FIXTURES.

SERVICES WITHIN THE CEILING:

X. FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR TERMINALS OR

OTHER SERVICES WEIGHING LESS THAN 20 LB. SHALL BE POSITIVELY

ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR CROSS RUNNERS

THAT HAVE THE SAME CARRYING CAPACITY OF THE MAIN RUNNERS.

Y. OTHER SERVICES OVER 20 LB. BUT LESS THAN OR EQUAL TO 56 LB. SHALL HAVE

2 ADDITIONAL #12 GA HANGAR WIRES FROM THE DEVICE TO THE STRUCTURE

ABOVE THAT ACT AS SAFETY WIRES. IT IS NOT NECESSARY FOR SAFETY WIRES

TO BE TAUT.

Z. OTHER SERVICES OVER 56 LB. SHALL BE SUPPORTED DIRECTLY FROM THE

STRUCTURE ABOVE BY APPROVED HANGERS.

3-5/8" METAL STUD WITH

FIRE RATED WOOD

BLOCKING TYP AT PANEL

ROUGH OPENING

5/8" GYPSUM BOARD,

OR LAY-IN ACT

CONCEALED PIANO OR SPRING

HINGE

SELF-TAPPING SCREWS

TYP.

SEALANT, TYP AROUND

ENTIRE OPENING

14 GAUGE MIN METAL DOOR

WITH 16 GAUGE MIN METAL

DOOR PANEL/FRAME

24"x24" RECESSED ACCESS

PANEL SERIES: KDW BY KARP

ASSOCIATES, INC. (OR

APPROVED EQUIVALENT) WITH

OPERATED HATCH CLOSER

NOTE: ACCESS HATCH TO BE COORDINATED WITH MECHANICAL

EQUIPMENT AND SHALL ALIGN WITH OTHER CEILING

COMPONENTS TO EXTENT POSSIBLE.

STRUCTURE

VERTICAL HANGING

WIRE

SPLAY WIRE SECURED TO

STRUCTURE, TYP

CROSS TEE

MAIN TEE

NOT TO SCALE

COMPRESSION BAR DETAIL

F

2" COLD ROLLED

STEEL CHANNELS AT

48" OC

NOT TO SCALE

ACCESS PANEL DETAIL

E

COMPRESSION BAR

SEE FLOOR PLANS FOR

WALL TYPES

SUSPENSION SYSTEM

HANGER WIRE

SEE RCP

FOR HEIGHT

SEE SPECS FOR TILE SIZE

AND PROFILE

15/16" SUSPENSION WALL ANGLE, OR

2" SUPPORT ANGLE IN SEISMIC ZONES

SUSPENSION SYSTEM

HANGER WIRE

15/16" SUSPENSION TEE

SEE SPECS FOR TILE SIZE

AND PROFILE

8" MAX

TO STRUCTURE

ABOVE

NOT TO SCALE

CEILING SUSPENSION DETAILS

A

SUSPENSION SYSTEM

HANGER WIRE

TO STRUCTURE

ABOVE

7/8" METAL FURRING

CHANNELS AT 16" OC

5/8" GYPSUM BOARD

WITH SMOOTH FINISH

SEAL JOINT BETWEEN WALL

AND GYPSUM BOARD CEILING

SEE FLOOR PLANS FOR

WALL TYPES

ADDITIONAL #12 GA. WIRES TO STRUCTURE FOR

LIGHT FIXTURE; SEE ASTM FOR

NUMBER OF WIRE REQUIREMENTS

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A131.DWG

8/1/2013 12:03:58 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

CE

ILIN

G D

ET

AIL

S

A-131

NE

K

ELN

NE

K

AS

N

OT

ED

AN

SI D

50740.T

N116.A

131.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

1122

Page 12: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

17

"-1

9"

34

"

INSULATE HOT

WATER AND

DRAIN PIPES WITH

UNDERLAVATORY

GUARD

12" 42"

19

"

33

"-3

6"

1'-6

"

39"-41"

FINISH FLOOR

3'-0

"

3'-0"

1'-6

"

19

"

17

"-1

9"

40

" M

AX

.

WH

EN

M

TD

.

OV

ER

L

AV

AT

OR

Y

BOTTOM OF

REFLECTIVE

SURFACE

WALL

WALL

℄ SINK & MIRROR

GB

TTD

GB

ADA TOILET

SIDE ELEVATION

ADA TOILET

FRONT ELEVATION

ADA LAVATORY W/ MIRROR

FRONT ELEVATION

GB

GB

TTD

GB

GB

UG

5"

5"

7-9"

SND

25

"- 3

0"

@ W

OM

EN

S

MR

1'-6"

3'-0

"

1/2" CEMENTITIOUS BACKER BOARD,

EACH SIDE

3-5/8" METAL STUDS @ 16" OC

WALL TILE, EACH SIDE

SOUND ATTENUATION BATTS;

FILL CAVITY

NON-RATED PARTITION W / TILE (BOTH SIDES)

EXTEND STUDS TO UNDERSIDE OF STRUCTURE

ABOVE; TILE SHALL EXTEND TO CEILING;

SEE TCNA # W244C-07

FURRING W/ TILE

EXTEND STUDS TO UNDERSIDE STRUCTURE;

EXTEND TILE TO CEILING;

SEE TCNA # W244C-07

3-5/8" METAL STUDS @ 16" OC

1/2"

CEMENTITIOUS BACKER

BOARD

WALL TILE

EXISTING WALL WITH TILE

EXTEND STUDS TO UNDERSIDE

OF STRUCTURE ABOVE.

1/2" CEMENTITIOUS BACKER BOARD

EXISTING STUD WALL

WALL TILE

EXISTING

TILE FLOOR;

SEE FINISH SCHEDULE

TILE BASE;

SEE FINISH SCHEDULE

PT 2X WOOD SLEEPERS

SET IN CONCRETE

PEDESTAL; ANCHOR EVERY

SECOND LOCKER TO PT 2X

SLEEPERS, TYP

EXISTING OR NEW WALL;

SEE FLOOR PLAN

6"

2"

EXISTING

OR NEW

LOCKER WIDTH

EXISTING OR NEW

LOCKER; SEE PLAN FOR

LOCKER DIMENSIONS

1"

WIDTH

BASED ON

LOCKER

SEALANT

ROUNDED BACK-UP WITH

NO BOND TO SEALANT

WATERPROOF MEMBRANE

REINFORCED

MORTAR BED

BOND COAT

CERAMIC TILE

DE

PT

H=

1/2

W

ID

TH

WIDTH = 4x

EXPECTED MOVEMENT

EXISTING

SLAB

COLD JOINT; APPLY EPOXY

BONDING AGENT TO EXISTING

SLAB TO ACCEPT NEW

CONCRETE

COMPRESSIBLE

BACKUP

REFER TO TCNA # EJ171-07,

"MOVEMENT JOINT

DESIGN ESSENTIALS"

LATRINE

ADJACENT

ROOM

EXISTING CONCRETE

SLAB

ADJACENT FINISH

ACCESSIBLE OR SLOPED

MARBLE THRESHOLD,

MAX 1/2" OFFSET FROM

EXISTING FINISH

1/2

"

MA

X

BOND COAT

FLEXIBLE SEALANT

BONDED WATERPROOF

MEMBRANE OVER CURB

CERAMIC TILE

THINSET OR THICKSET

REINFORCED MORTAR BED

REFER TO TCNA # TR611-07

SEALANT

ROUNDED BACK-UP WITH

NO BOND TO SEALANT

WATERPROOF MEMBRANE

CERAMIC TILE

DE

PT

H=

1/2

W

ID

TH

WIDTH = 4x

EXPECTED MOVEMENT

NEW

SLAB; SEE A-002

FOR SLAB

REPLACEMENT &

REMOVAL

NOTES

COLD JOINT; APPLY EPOXY

BONDING AGENT TO EXISTING

SLAB TO ACCEPT NEW

CONCRETE OR MEMBRANE

COMPRESSIBLE BACKUP

REINFORCED MORTAR BED

REFER TO TCNA # EJ171-07,

"MOVEMENT JOINT

DESIGN ESSENTIALS"

& WALL DETAILS

NEW CMU OR

STUD WALL;

SEE PLAN FOR

WALL TYPES &

SUBSTRATE

BOND COAT

MORTAR

BOND COAT

DEMO 2" WIDER

THAN WALL

DIMENSION

OVERHEAD BRACED

PARTITION

URINAL

PARTITION

OVERHEAD

BRACE

SOLID

PHENOLIC,

TYP.

SOLID

PHENOLIC,

TYP.

4'-1

0"

7'-0

"

1'-0

"

4'-0

"1

'-0

"

TUP TUP

44

"- 4

8"

SD

44

"- 4

8"

PTD

2

2' 0 2' 4'4'

1

1/4"=1'-0"

AMSA - FAC 00002

ENLARGED PLAN

0 1' 2' 3'1'2'3'

3

3/8"=1'-0"

ADA COMPLIANT MOUNTING HEIGHTS FOR TOILET ACCESSORIES

1

2

GB

GB

TTD

TTD SND

PTD

SD

PTD

SD

1

01' 1'6"

4

1"=1'-0"

WALL TYPES

2

MR

MR MR

NEW METAL LOCKERS ON

EXISTING BASE;

FILLER PANELS AS

REQUIRED

NEW METAL LOCKERS ON

CONC. BASE

2

3

PLAN

NORTH

0 1'4" 2"

7

1-1/2"=1'-0"

LOCKER BASE DETAIL

01' 1'6"

6

1"=1'-0"

TILE EXPANSION JOINT DETAIL

7

A-401

6

A-401

6

A-401

WOMEN

112

MEN

106

LOCKERS

107

0 1'4" 2"

8

1-1/2"=1'-0"

THRESHOLD DETAIL

01' 1'6"

5

1"=1'-0"

WALL EXPANSION JOINT DETAIL

8

A-401

5

A-401

FD

FD

MARBLE

THRESHOLD,

TYP

3

3

1 2 3 4

1 2 3 4

5

6

7

8

910111213141516

TOILET ACCESSORY LEGEND

GRAB BAR & VERTICAL GRAB BAR

SOAP DISPENSER

SANITARY NAPKIN DISPOSER

TOILET TISSUE DISPENSER

GB

SD

SND

TTD

MIRRORMR

TOILET/URINAL PARTITIONTUP

DENOTES FIXTURE CLEARANCE

PAPER TOWEL DISPENSERPTD

GENERAL NOTES

FLOOR DRAIN

FD

UNDERLAVATORY GUARDUG

2' 0 2' 4'4'

2

1/4"=1'-0"

AMSA - FAC 00002

ENLARGED

DIMENSIONED PLAN

1'-2"

F.V.

5'-1

1"

CL

R

5'-0

" C

LR

5'-0" CLR

5'-4

" C

LR

PLAN

NORTH

WOMEN

112

MEN

106

LOCKERS

107

1'-0

"

TUP

TUP

1'-3

"1

'-6

"1

'-6

"

2'-4" 2'-8" 1'-3"

5'-1" CLEAR

6

A-401

EJ

EJ

EJ

A L

I G

N

A L I G N

A. PATCH AND REPAIR FLOORS AND WALLS AS REQUIRED

TO RECEIVE NEW FINISHES, AND PROVIDE NEW

MORTAR BED FOR ALL TILE. SEE DEMOLITION PLANS

FOR EXTENT OF SLAB REPLACEMENT.

B. ALL WALLS WITHIN LATRINES NOT INDICATED WITH

WT-1 SHALL RECEIVE 6" TILE BASE (WT-1) UNO.

C. ALL TOILET ACCESSORIES SHALL BE REPLACED - SEE

SPECIFICATIONS AND ADA MOUNTING HEIGHTS.

D. PROVIDE UNDERLAVATORY GUARDS AT ALL SINKS

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A401.DWG

8/1/2013 12:04:08 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AM

SA

- F

AC

00

00

2

EN

LA

RG

ED

P

LA

NS

&

E

LE

VA

TIO

NS

A-401

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

401.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

TYP

TYP

TUP

1222

Page 13: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

12

3 4

H-1

2' 0 2' 4'4'

2

1/4"=1'-0"

ALUMINUM ENTRANCE & WINDOW ELEVATIONS

GENERAL NOTES

C

H-2

J-2B

S-2

7'-4

"

3'-4" 2'-2"

5'-4

"

5'-0

"

5'-0"

5'-0

"

5'-4"

4'-4

" F

V

5'-0" 5'-0" 4'-11"5'-2"

S-4

H-4A

J-4B

DBA

S-1

2'-0

"

2'-0

"

T

J-3

H-3

S-3

2'-0

"

DOOR & WINDOW ELEVATION LEGEND

DENOTES TEMPERED GLAZING

T

T

T

J-4ASIM

J-4C SIM

81'-1" FV

7'-2

"

3'-0"

114

2' 0 2' 4'4'

1

1/4"=1'-0"

DOOR ELEVATIONS

J-1C

FIXED ALUMINUM WINDOW,

IN EXISTING METAL PANELS

BOD = YKK YES 45 TU

FIXED ALUMINUM WINDOW,

IN EXISTING BRICK

BOD = YKK YES 45 TU

ALUMINUM STOREFRONT ENTRANCE,

IN EXISTING BRICK

BOD = YKK YES 45 TU

FIXED ALUMINUM WINDOW

OVER ALUMINUM PROJECTED AWNING WINDOW,

IN EXISTING BRICK & METAL PANELS ABOVE;

BOD = YKK YOW 350T;

PROVIDE INSECT SCREEN

HEAVY DUTY, MEDIUM STYLE,

FULL GLASS, ALUMINUM DOOR

BOD = YKK 20D

NOTE:

AT HIGH BAY PROJECTED AWNINGS, PROVIDE

MANUFACTURER STANDARD OR COMPLEMENTARY

SURFACE MOUNTED MECHANICAL OPERATING DEVICE

FOR EACH OPERABLE WINDOW (ONE PER JAMB).

1'-7" FV

2'-2"

J-4CJ-4A

J-4C SIM

10

'-0

" F

V

J-2A J-3

H-4B

ADJACENT BRICK

METAL PANELS

ADJACENT BRICK

ADJACENT BRICK

PROJECTED AWNING

J-1A

J-1B

5'-4" 5'-4" 5'-4" 5'-5" 5'-6" 5'-4" 5'-4" 5'-4" 5'-6" 5'-6" 5'-4" 5'-4" 5'-4" 5'-6" 5'-8"

4" 4" 4"

5'-0"

8"

5'-0"

4"

5'-0"

4"

5'-0"

4"

5'-0"

4"

5'-0"

8"

5'-0"

4"

5'-4"

8"

5'-0"

4"

5'-0"

4"

5'-0"

4"

REMOVE & REINSTALL

DOWNSPOUT AS REQUIRED FOR

INSTALLATION OF WINDOWS, TYP

ROOF GUTTER

METAL PANELS @ HEADBRICK @ HEAD

EXISTING BRICK

CONTROL JOINT

TO REMAIN, TYP;

PROVIDE NEW SEALANT TO

MATCH EXISTING AS

REQUIRED

REMOVE & REINSTALL

DOWNSPOUT AS REQUIRED FOR

INSTALLATION OF WINDOWS, TYP

BRICK ROWLOCK

PROVIDE CONTINUOUS SILL

FLASHING & 2-PART THROUGH

WALL FLASHING 8" BELOW

SILL; PROVIDE NEW 8" FACE

BRICK AND MORTAR TO

MATCH EXISTING; PROVIDE

WEEPS AT 16" O.C.

LINE OF METAL PANEL

BULKHEAD; FLASHING DROPS

BELOW WINDOW HEAD - SEE

DEMOLITION PHOTOS

EXISTING BRICK

CONTROL JOINT

TO REMAIN, TYP;

PROVIDE NEW SEALANT TO

MATCH EXISTING AS

REQUIRED

H-1 DENOTES CALLOUT FOR HEAD, JAMB, OR SILL DETAIL

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A501.DWG

8/1/2013 12:04:17 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

DO

OR

A

ND

W

IN

DO

W

ELE

VA

TIO

NS

&

D

ET

AIL

S

A-501

NE

K

ELN

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.A

501.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

A. SEE SPECIFICATIONS FOR ALL RELATED WORK INCLUDING, BUT NOT LIMITED TO,

STEEL FABRICATIONS, ROUGH CARPENTRY, FINISH CARPENTRY, SOLID SURFACING,

FLASHING & SHEET METAL, JOINT SEALANTS, DOOR HARDWARE, GLAZING, GYPSUM

BOARD, PAINTS & COATING, ETC.

B. PROTECT ALL EXISTING ADJACENT CONSTRUCTION MATERIALS AROUND OPENING.

IF ANY MATERIAL IS DAMAGED DURING DEMOLITION, PATCH AND REPAIR AS

REQUIRED TO MATCH EXISTING CONDITIONS.

C. ALL MASONRY ROUGH OPENINGS VARY IN SIZE, AND OPENING DIMENSIONS

INDICATED ARE NOMINAL. CONTRACTOR SHALL FIELD MEASURE EACH AND EVERY

EXISTING OPENING AFTER DEMOLITION TO CONFIRM SIZES INDICATED, PRIOR TO

SHOP DRAWINGS AND FABRICATION.

D. AT ALL EXISTING WINDOW OPENINGS WITH EXPOSED STEEL, SUCH AS LINTELS OR

HEAD PLATES, STRIP EXISTING PAINT AFTER WINDOW DEMOLITION. PROVIDE

PRIMER AND EXTERIOR RUST PROHIBITING WATER-BASED SEMI-GLOSS ENAMEL

PAINT TO MATCH EXISTING COLOR, UNO.

E. SEE FINISH SCHEDULE LEGEND FOR INTERIOR ROOM FINISHES, SOLID SURFACE

SILLS, AND PAINTS. ALL EXTERIOR PAINTS SHALL MATCH EXISTING SURFACES. ALL

INTERIOR PAINTS SHALL MATCH ADJACENT INTERIOR FINISHES, UNO. ALL

SEALANTS AT WINDOW FRAME AND FLASHING SHALL MATCH WINDOW. ALL

SEALANTS AT INTERIOR FINISHES OR WALLS SHALL MATCH ADJACENT FINISHES.

ALL REPLACEMENT MORTAR SHALL MATCH EXISTING MORTAR.

F. CONTRACTOR SHALL COORDINATE ALL DOOR HARDWARE WITH EXISTING

ELECTRICAL, SECURITY, ACCESS CONTROL, ETC. AS REQUIRED.

G. ALL STOREFRONT ENTRANCES & ALUMINUM WINDOWS SHALL BE BY THE SAME

MANUFACTURER TO THE EXTENT POSSIBLE. ALL ALUMINUM WINDOW SYSTEMS

SHALL BE PRE-FINISHED ARCHITECTURAL CLASS II, A32 INTEGRAL COLOR

ANODIZED, COLOR "MEDIUM BRONZE". ALL ALUMINUM PAN FLASHING SHALL MATCH

WINDOW FINISH.

H. FOR ALUMINUM WINDOWS:

1. SEE SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS, PERFORMANCE DATA, AND

PRODUCT DATA.

2. AT A MINIMUM, PROVIDE SHOP DRAWINGS THAT INDICATE ELEVATIONS OF

WINDOWS, FULL-SIZE SECTIONS, THICKNESS AND GAGES OF METAL, FASTENINGS,

PROPOSED METHOD OF ANCHORING, SIZE AND SPACING OF ANCHORS, DETAILS

OF CONSTRUCTION, METHOD OF GLAZING, DETAILS OF OPERATING HARDWARE,

MULLION DETAILS, METHOD AND MATERIALS FOR WEATHERSTRIPPING,METHOD

OF ATTACHING SCREENS, MATERIAL AND METHOD OF ATTACHING

SUBFRAMES,STOOLS, CASINGS, SILLS, TRIM,WINDOW CLEANER ANCHORS,

INSTALLATION DETAILS, AND OTHER RELATED ITEMS WHICH MAY NOT BE DRAWN

3. DESIGN WINDOW COMPONENTS, INCLUDING MULLIONS, HARDWARE, AND

ANCHORS, TO WITHSTAND A WIND-LOADING DESIGN PRESSURE OF AT LEAST 50

POUNDS PER SQUARE FOOT (PSF).

4. WINDOWS, AND GLAZING, SHALL HAVE SOLAR HEAT GAIN COEFFICIENT (SHGC)

MAXIMUM OF 0.25 AND A U-FACTOR MAXIMUM OF 0.46.

5. PROVIDE PRIME WINDOWS THAT COMPLY WITH AAMA/WDMA/CSA 101/I.S.2/A440

AND THE REQUIREMENTS SPECIFIED HEREIN.

6. AWNINGS SHALL BE TYPE AP-CW30.

7. FIXED WINDOWS SHALL BE TYPE F-CW30.

8. FABRICATION OF WINDOW UNITS MUST COMPLY WITH AAMA/WDMA/CSA

101/I.S.2/A440. PROVIDE FOR VENTILATING SECTIONS OF ALL WINDOWS,

WEATHERSTRIPPING, CONTINUOUS DRIPS OVER HEADS OF TOP VENTILATORS,

MULLIONS WITH A THERMAL BREAK, MULLION COVERS, HARDWARE, FASTENINGS,

ANCHORING DEVICES FOR WINDOW AND ALL SUBPARTS, GLAZING BEADS,

EXTRUSION PROFILES AT MULLION COVERS AS INDICATED, ONE VENT SCREEN

PER OPERABLE SASH, SPECIAL OPERATORS AS INDICATED, AND MECHANICAL

OPERATORS AS INDICATED

1322

Page 14: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

ALUMINUM STOREFRONT

SYSTEM

ALUMINUM STOREFRONT

DOOR

EXISTING EXT GWB CEILING;

PATCH AS REQD FROM DEMO

EACH SIDE

EXISTING MASONRY

(S-1) - THRESHOLD

ALUMINUM STOREFRONT

DOOR

MAX 1/2" ADA THRESHOLD SET

IN CONTINUOUS SEALANT

EXISTING CONCRETE SLAB

(J-1B) - JAMB

(H-1) - HEAD

ALUMINUM STOREFRONT

HEAD

DOOR THRESHOLD

DUAL SEAL WITH BACKER ROD

& SEALANT

1/2

" M

AX

DUAL SEAL WITH BACKER ROD

& SEALANT

CONTINUOUS SEALANT

(J-1C) - JAMB(J-1A) - JAMB

REPAIR ANY DAMAGED

FLOORING TO MATCH

EXISTING

SOLID SURFACE SILL

1"

(S-2) - SILL

CONTINUOUS SEALANT

1/2"

10" FV

4 1/2"

METAL PANEL

ALUMINUM SILL PAN WITH 2"

BACK & END DAM DAM SET IN

BED OF MASTIC; SLOPE TO DRAIN

WITH MIN 1/2" HEMMED DRIP

ALUMINUM WINDOW

10

" F

V

1/2

"4

1

/2

"

ALUMINUM WINDOW

EXISTING METAL PANEL

SOLID SURFACE SILL,

BELOW

EDGE OF METAL PANEL

COMPRESSIBLE GASKET

BEYOND

12

" F

V

SILL PAN, BELOW

EXISTING METAL PANEL

EXISTING 4" CMU

EXISTING STEEL PLATE;

PAINT TO MATCH

EXISTING ADJACENT

WALLS;

SEE GENERAL NOTES

(J-2B) - JAMB

(H-2) - HEAD

DUAL SEAL WITH BACKER

ROD & SEALANT

DUAL SEAL WITH BACKER ROD

& SEALANT

DUAL SEAL WITH BACKER ROD

& SEALANT BELOW EXISTING

HEAD FLASHING

CONTINUOUS SEALANT

CONTINUOUS SEALANT

EXISTING METAL PANEL BASE/

HEAD FLASHING; DO NOT

REMOVE

WINDOW MANUFACTURER

SETTING PAN WITH WEEPS

& THERMAL BREAK SET IN

SITE-BUILT SILL PAN

EDGE OF METAL PANEL

FLASHING BEYOND

ENTIRE JAMB IS WRAPPED

WITH METAL PANEL

COMPRESSIBLE GASKET /

FLASHING; PROVIDE

CONTNUOUS SEALANT

WHERE SILL PAN MEETS

FLASHING; TOUCH UP PAINT

FLASHING AS REQD

EXISTING BRICK, BEYOND

(J-2A) - JAMB

#

1. COPPER STEP FLASHING SET IN BRICK WITH LEAD WEDGE; PROVIDE SEALANT

TO BRICK AT VERTICAL EDGES; LEAVE BOTTOM OPEN.

2. COPPER FLASHING WITH 6" MIN VERTICAL LEG AND 1/2" HEMMED DRIP; SOLDER

TO STEP FLASHING AT VERTICAL AND HORIZONTAL EDGES TO MAKE

WATERTIGHT.

3. LAP SELF-ADHERING FLEXIBLE FLASHING OVER COPPER FLASHING BELOW.

4. SET ALUMINUM SILL PAN WITH 1" END AND BACK DAM IN MASTIC.

5. LAP SELF-ADHERING FLEXIBLE FLASHING OVER SILL PAN AND 2" OF COPPER

STEP FLASHING; DO NOT WRAP EXPOSED STEP FLASHING ENTIRELY AT JAMB.

DETAIL KEY NOTES

1

3

5

4

2

#

1. EXISTING STEEL "TEE COLUMN" AND PT 2X BLOCKING; DETAIL

SIMILAR FOR EXISTING W-SHAPE COLUMNS.

2. COPPER FLASHING WITH 6" MIN VERTICAL LEG AND 1/2"

HEMMED DRIP.

3. WRAP EXISTING "TEE COLUMN" AND BLOCKING AT JAMB WITH

SELF-ADHERING FLEXIBLE FLASHING AND LAP OVER COPPER

FLASHING BELOW.

4. COPPER COLUMN FLASHING "BOOT" WITH 3" MIN VERTICAL LEG;

SOLDER DAM TO PAN OR PROVIDE SOLDERED ONE-PIECE TO

ACHIEVE PROFILE.

5. SEALANT BED TO RECEIVE LAPPED SILL PAN.

6. SET ALUMINUM SILL PAN WITH 1" MIN END AND BACK DAM IN

MASTIC. ENSURE FULL SEALANT BED AT ALL LAPS.

7. LAP SELF-ADHERED FLEXIBLE FLASHING OVER SILL PAN END

DAM AND COLUMN FLASHING.

DETAIL KEY NOTES

1

2

4

5

6

7

3

EXISTING BRICK

EXISTING BRICK,

BEYOND

SOLID SURFACE SILL

1"

CONTINUOUS SEALANT

3 1/2" 4 1/2"

ALUMINUM SILL PAN WITH 2"

BACK & END DAM DAM SET IN

BED OF MASTIC; SLOPE TO DRAIN

WITH MIN 1/2" HEMMED DRIP

ALUMINUM WINDOW

DUAL SEAL WITH BACKER ROD

& SEALANT

WINDOW MANUFACTURER

SETTING PAN WITH WEEPS

& THERMAL BREAK SET IN

SITE-BUILT SILL PAN

EXISTING BRICK

ROWLOCK

ALUMINUM WINDOW

12

" F

V

(J-3) - JAMB

EXISTING BRICK

(H-3) - HEAD

DUAL SEAL WITH BACKER ROD

& SEALANT

EXISTING STEEL ANGLE;

PAINT TO MATCH ADJACENT

EXTERIOR FINISHES;

SEE GENERAL NOTES

EXISTING 8" CMU

CONTINUOUS SEALANT

SOLID SURFACE SILL,

BELOW

EXISTING STEEL ANGLE;

PAINT TO MATCH

EXISTING ADJACENT

WALLS;

SEE GENERAL NOTES

SILL PAN, BELOW

0 3" 6"2" 1"

1

3"=1'-0"

HEAD/JAMB/SILL DETAILS

0 3" 6"2" 1"

2

3"=1'-0"

HEAD/JAMB/SILL DETAILS

NOT TO SCALE

FLASHING ISOMETRIC DETAIL

4

NOT TO SCALE

FLASHING ISOMETRIC DETAIL

5

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A502.DWG

8/1/2013 12:04:27 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

DO

OR

&

W

IN

DO

W D

ET

AILS

A-502

NE

K

ELN

AS

N

OT

ED

AN

SI D

50740.T

N116.A

502.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

0 3" 6"2" 1"

3

3"=1'-0"

HEAD/JAMB/SILL DETAILS

1422

Page 15: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

(S-4) - SILL

12" FV

EXISTING BRICK;

DEMO 8" BELOW SILL TO ALLOW

FOR NEW THROUGH WALL

FLASHING AND BRICK ROWLOCK

ALUMINUM SILL PAN WITH 1"

BACK & END DAM DAM SET IN

BED OF MASTIC; SLOPE TO DRAIN

WITH MIN 1/2" HEMMED DRIP

ALUMINUM WINDOW

3 1

/2

"5

1

/2

"

EXISTING BRICK

NEW COPPER STEP FLASHING

SET IN EXISTING BRICK WITH

LEAD WEDGE; SOLDER STEP

FLASHING TO CONTINUOUS

THROUGH WALL FLASHING

VERTICALLY AT BOTH END

DAMS PRIOR TO NEW BRICK

ROWLOCK; EXTEND STEP

FLASHING 8" MIN

HORIZONTALLY FROM JAMB

12

" F

V

SILL PAN, BELOW

EXISTING FACE OF CMU &

CMU ABOVE

(J-4B) - JAMB

(H-4A) - HEAD

DUAL SEAL WITH BACKER ROD

& SEALANT

DUAL SEAL WITH BACKER ROD

& SEALANT

CONTINUOUS SEALANT

4 1

/2

" F

V

1'-0

"

3 1

/2

"3

1

/2

"2

"

4 1

/2

" F

V6

" F

V

3 1/2" 3 1/2" 2"

EXISTING STEEL PLATE; PAINT

TO MATCH EXISTING; SEE

GENERAL NOTES

(J-4A) - JAMB

FIXED SASH

(J-4C) - JAMB

ALUMINUM WINDOW

CONTINUOUS SEALANT

AROUND SILL PAN AND

FRAME; MATCH WINDOW

COLOR

WINDOW MANUFACTURER

SETTING PAN / FRAME WITH

THERMAL BREAK SET IN

SITE-BUILT SILL PAN

LINE OF METAL PANELS

OVER SOME WINDOWS

WINDOW FRAME TRIM KIT

PROJECTED AWNING SASH

(H-4B) - HEAD

/ MEETING RAIL

PREMANUFACTURED 1" DEEP

EXTRUSION COVER PLATE TO

MATCH WINDOWS; TYP AT

BOTH MULLION TYPES

EXISTING STEEL

COLUMN

EXISTING 5"x3" "TEE COLUMN",

EACH JAMB

EXISTING 6"x6" STEEL PLATE

FOR "T" COLUMN

CONTINUOUS TWO PIECE

THROUGH WALL FLASHING; LAP

FLEXIBLE FLASHING OVER METAL

FLASHING WITH MIN 6" VERTICAL

LEG & 1/2" HEMMED DRIP

ROWLOCK AND ONE COURSE TO

MATCH EXISTING FACE BRICK AND

MORTAR WITH WEEPS @ 16' OC

8" MIN

COPPER FLASHING ABOVE;

SOLDER AT VERTICAL EDGE

SEALANT AT ALL LAPS IN SILL

FLASHING

LEAD WEDGE &

SEALANT SET IN BRICK

EXISTING 5"x3"

"TEE COLUMN", EACH JAMB

1"

8"

4"

FL

AS

HIN

G R

ET

UR

N

6"

NOTE:

INSECT SCREEN NOT SHOWN

FOR CLARITY.

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.A503.DWG

8/1/2013 12:04:35 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

WIN

DO

W D

ET

AIL

S

A-503

NE

K

ELN

AS

N

OT

ED

AN

SI D

50740.T

N116.A

503.D

WG

8/1/2013

DLB

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

0 3" 6"2" 1"

1

3"=1'-0"

HEAD/JAMB/SILL DETAILS

1522

Page 16: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND

#

1. REMOVE EXISTING FLUSH VALVE WATER CLOSET. CAP WASTE CONNECTION BELOW

FLOOR. REMOVE EXISTING WATER SUPPLY BACK TO ABOVE THE CEILING, BACK TO

THE MAIN SUPPLY. REMOVE FIXTURE VENT PIPING BACK TO ABOVE THE CEILING

AND TEMPORARILY CAP FOR FUTURE CONNECTION.

2. REMOVE EXISTING WALL MOUNTED LAVATORY AND ASSOCIATED TRIM. REMOVE

EXISTING HOT AND COLD WATER BACK TO MAIN SUPPLIES ABOVE CEILING. REMOVE

FIXTURE WASTE TO BELOW FLOOR AND CAP WASTE CONNECTION. REMOVE

FIXTURE VENT PIPING BACK TO MAIN VENT PIPING ABOVE THE CEILING AND CAP.

3. REMOVE EXISTING WALL MOUNTED LAVATORY AND ASSOCIATED TRIM. EXISTING

HOT & COLD WATER SUPPLY STUB-OUTS AND EXISTING WASTE/VENT CONNECTION

STUB-OUT TO REMAIN FOR FUTURE CONNECTION TO NEW FIXTURE.

4. REMOVE EXISTING WALL MOUNTED URINAL AND ASSOCIATED TRIM. EXISTING

WATER SUPPLY STUB-OUT AND EXISTING WASTE/VENT CONNECTION STUB-OUT TO

REMAIN FOR FUTURE CONNECTION TO NEW FIXTURE.

5. REMOVE EXISTING FLOOR DRAIN. TEMPORARILY CAP WASTE CONNECTION FOR

NEW FLOOR DRAIN CONNECTION. CAP TRAP PRIMER PIPING BELOW FLOOR.

6. REMOVE EXISTING HOSE BIBB. REMOVE WATER SUPPLY BACK TO ABOVE CEILING

AND CAP.

7. CONNECT 1-1/2"C TO EXISTING COLD WATER SUPPLY MAIN ABOVE CEILING. FIELD

VERIFY LOCATION OF EXISTING COLD WATER SUPPLY MAIN ABOVE CEILING PRIOR

TO BEGINNING WORK.

8. CONNECT 1/2"H TO EXISTING HOT WATER SUPPLY MAIN ABOVE CEILING. FIELD

VERIFY LOCATION OF EXISTING HOT WATER SUPPLY MAIN ABOVE CEILING PRIOR

TO BEGINNING WORK.

9. CONNECT NEW LAVATORY P3 TO EXISTING HOT & COLD WATER SUPPLIES AND

WASTE/VENT CONNECTION IN WALL.

10. CONNECT NEW URINAL P2 TO EXISTING COLD WATER SUPPLY AND WASTE/VENT

CONNECTION IN WALL.

11. CONNECT FLOOR DRAIN - FD TO EXISTING 3" WASTE CONNECTION IN FLOOR.

12. CONNECT 3"W TO EXISTING 4"W. FIELD VERIFY LOCATION OF EXISTING WASTE

PIPING PRIOR TO BEGINNING WORK.

13. CONNECT 2"V TO EXISTING 4"VTR. FIELD VERIFY LOCATION OF EXISTING VENT

PIPING PRIOR TO BEGINNING WORK.

PLUMBING KEY NOTES

WOMEN

112

PLAN

NORTH

2' 0 2' 4'4'

1

1/4"=1'-0"

AMSA - FAC 00002

PLUMBING DEMOLITION PLAN

PLAN

NORTH

2' 0 2' 4'4'

2

1/4"=1'-0"

AMSA - FAC 00002

HOT & COLD WATER PIPING PLAN

PLAN

NORTH

2' 0 2' 4'4'

3

1/4"=1'-0"

AMSA - FAC 00002

WASTE & VENT PIPING PLAN

MEN

106

LOCKERS

107

WOMEN

112

MEN

106

LOCKERS

107

WOMEN

112

MEN

106

LOCKERS

107

1

11

2

3

3

4

5

5

P1

P1

P2

P3P3

P3

P1

P1

FD

FD

P2

P3P3

P3

6

6

7

8

1-1/2"C

1-1/2"C

1-1/4"C

1/2"C

1/2"H

9 9 9 9

10 10

EXT'G 4"W

EXT'G 4"VTR

1-1/2"V

3"W

3"W

2"V

2"V

11

11

12

13

EXT'G 1"H

EXT'G 2"C

ITEM

P1

P3

P2

MOUNTING HEIGHT / REMARKS

17" RIM HT. / WALL HUNG / BATTERY, 0.125 GPF

18" RIM HT. / FLOOR MTD., BATTERY DUAL FLUSH VALVE

34" RIM HT. / WALL HUNG / BATTERY POWERED

FIXTURE SCHEDULE

DESCRIPTION

SENSOR URINAL - HDC'P

SENSOR LAVATORY - HDC'P

SENSOR WATER CLOSET - HDC'P

1/2"

---

---

HOT

WATER

1/2"

1-1/4"

3/4"

1-1/4"

3"

2"

COLD

WATER

WASTE

1-1/2"

1-1/2"

2"

VENT

(ABOVE FLOOR)

TRAP

PROVIDE TRAP GUARD

DRAIN INSERT

FLOOR DRAIN (FD)

NOT TO SCALE

4

A. PROVIDE ALL MATERIALS AND LABOR NECESSARY FOR A COMPLETE PLUMBING

SYSTEM. WARRANTY ALL WORK AND MATERIAL FOR A PERIOD OF AT LEAST ONE

YEAR AFTER ACCEPTANCE BY OWNER.

B. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS

OF: INTERNATIONAL PLUMBING CODE, 2009 EDITION.

ANSI

UNDERWRITERS LABORATORIES (UL)

C. DO NOT SCALE DRAWINGS. OBTAIN ROUGH-IN DIMENSIONS FROM ARCHITECTURAL

DRAWINGS OR FROM MANUFACTURERS PRINTED INSTRUCTIONS AND

RECOMMENDATIONS ONLY. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS

OF ALL EQUIPMENT, CONNECTIONS AND LINES WITH THE OWNER PRIOR TO

INSTALLATION OF ANY PIPING.

D. ALL EXT'G UTILITIES ARE SHOWN IN APPROXIMATE LOCATIONS ONLY. VERIFY EXACT

LOCATIONS AND INVERT ELEVATION IN FIELD BEFORE BEGINNING WORK.

E. COORDINATE PLUMBING SYSTEMS WITH ALL TRADES TO AVOID INTERFERENCE

AND CONFLICTS PRIOR TO INSTALLATION OF PIPING, FIXTURES, AND EQUIPMENT.

F. COORDINATE WITH AND OBTAIN PERMITS AND INSPECTIONS FROM AUTHORITY

HAVING JURISDICTION.

G. PROVIDE OWNER WITH CERTIFICATES OF FINAL INSPECTION FROM AUTHORITY

HAVING JURISDICTION.

H. WHENEVER THE WORD "PROVIDE" IS USED, IT SHALL MEAN FURNISH AND INSTALL

COMPLETE AND READY FOR USE.

I. UNLESS OTHERWISE SHOWN OR NOTED, ALL PIPING SHALL BE RUN CONCEALED IN

WALLS, CHASES AND/OR ABOVE CEILINGS.

J. ALL SUSPENDED PIPING SHALL BE SUPPORTED FROM FLOOR AND/ OR ROOF

STRUCTURAL MEMBERS. IN NO CASE SHALL PIPING BE SUSPENDED FROM FLOOR

OR ROOF DECK.

K. WHERE PIPES PENETRATE FIRE RATED ASSEMBLIES, SEAL OPENING AROUND PIPES

WITH U.L. LISTED FIRE STOPPING MATERIAL TO MAINTAIN THE FIRE RATING OF THE

ASSEMBLY.

L. PROVIDE ALL VENT PENETRATIONS WHERE INDICATED ON FLOOR PLANS. COLLECT

ALL VENTS ABOVE CEILING WHERE SHOWN.

PLUMBING GENERAL NOTES:

PLUMBING SYMBOLS & LEGEND:

TYP

EXT'G

B/F

A/C

FD

VTR

FCO

WCO

BV

FD

FCO

TYPICAL

ABOVE CEILING

BELOW FLOOR

CONNECT TO EXISTING

EXISTING

BALL VALVE

FLOOR DRAIN

VENT THRU ROOF

WALL CLEAN OUT

FLOOR CLEANOUT

ABBREVIATION

C

H

V

W

SYMBOL

SOIL AND WASTE PIPING

VENT PIPING

DESCRIPTION

COLD WATER PIPING

HOT WATER PIPING

P

P

P

P

P

P

P

P P P P P P

NOTES:

ALL SUPPLY AND WASTE LINES SHALL BE CONCEALED IN ADJACENT WALL, FLOOR AND CEILING, UNLESS NOTED

OTHERWISE. PROVIDE TYPE "AA" WATER HAMMER ARRESTORS AT EACH FIXTURE, UNLESS NOTED OTHERWISE.

SLOPED

FLOOR

SLAB

5" STRAINER SET

FLUSH WITH FLOOR

PROVIDE SQUARE TOP

FOR TILE FLOORS

*** Safety Pays ***

*** Support Value Engineering - It Pays ***

SO

LIC

IT

AT

IO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR

.

DA

TE

:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BM

IT

TE

D B

Y:

PL

OT

S

CA

LE

:P

LO

T D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT

OR

N

O.:

SHEET

IDENTIFICATION

DA

TE

AP

PR

.

SHEET OF

®

US Army Corps

of Engineers

I:\COE-CHARLESTON.14254\50740.RESETS-REPAIR-M\DOCS\DWG\SHEETS\TN116\50740.TN116.P101.DWG

8/1/2013 12:04:42 AM

81S

T R

SC

R

ES

ET

P

RO

JE

CT

S - T

N

AM

SA

- F

AC

00

00

2

PLU

MB

IN

G P

LA

NS

P-101

TP

L

TP

L

LIN

DB

ER

GH

&

A

SS

OC

IA

TE

S

AS

N

OT

ED

AN

SI D

50740.T

N116.P

101.D

WG

8/1/2013

TM

F

AU

GU

ST

1, 2013

CHARLESTON DISTRICT

CH

AR

LE

ST

ON

D

IS

TR

IC

T

1622

Page 17: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND
Page 18: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND
Page 19: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND
Page 20: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND
Page 21: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND
Page 22: TN116 - LIGHTING, LATRINE, WINDOW UPGRADE …...TN116 - LIGHTING, LATRINE, WINDOW UPGRADE WITH CEILING TILES 160 WHITE BRIDGE ROAD, NASHVILLE, TN 37416 81ST REGIONAL SUPPORT COMMAND