28
Made In Japan Digital Inverter System Super Digital Inverter System Applicable to certain models.

Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Embed Size (px)

Citation preview

Page 1: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Made In Japan

Digital Inverter System

SuperDigital Inverter System

Applicable tocertain models.

Page 2: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Toshiba can help you create a comfortable offi ce and home while also caring for the environment.

02

Page 3: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Super Digital InverterSDILatest technology: Newly developed DC twin-rotary compressor, Vector-controlled inverter, Larger propeller fan,

High efficiency DC fan motor, High efficiency heat-transfer and New grille design has excellent efficiency, not only

under rated EER conditions, but also during partial load which is the larger part of actual operating conditions.

Low-noise design: If the outdoor temperature is 30°C or less, operates at under 45 dB

The industry’s first magnetic-action control

The new structure allows a huge reduction in energy loss.

The balanced magnetic-action force to rise and the rotor’s weight minimized the friction laid on the axis

provides excellent operation efficiency.

Friction loss Reducing friction loss

Stator RotorRotor’s weight

Magnetic center

Magnetic action

Current model New model

Outdoor temperature operating range in heating (Wider heating operation)

Heater operation is possible starting from an outdoor temperature of -20°C, while cooling operation is

possible at -15°C outdoor temperature. Creates a comfortable space even during cold winters.

Frost protection

8°C operation for frost protection is possible for the combination with Super Digital Inverter. (4-Way and Slim

Duct series 4)

Sub cool path

Improve reliability for smooth drainage. The outdoor unit of New Super Digital Inverter is equipped with

“Sub cool path” Preventing freeze under a heat exchanger. (Only 3HP to 6HP)

Compatible with pipes up to 75 meters long

Enable the outdoor unit to be installed out of sight increases installation flexibility.

03

Page 4: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Physical data Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E

Standard air flow (H/M/L) m3/h 1050/870/780 1230/960/810 2010/1440/1170 2100/1440/1230

Sound pressure level (H/M/L) dB(A) 32/29/28 35/31/28 43/38/33 44/38/34

Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840

Weight kg 20 20 24 24

Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950

Panel weight kg 4.2 4.2 4.2 4.2

Physical data Equivalent HP 2HP 3HP 4HP 5HP

Out door unit Standard model (RAV-) SP564ATP-SG SP804ATP-SG SP1104AT-SG SP1404AT-SG

Power supply 1-phase 50Hz 230V (220–240V)

Compressor type DC twin rotary

Running Amphere A 5.57 6.21 9.94 13.82

Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5

Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 3 7.5 / 3

Max. pipe total length m 50 50 75 75

Maximum height difference m 30 30 30 30

Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320 1340/900/320

Weight kg 44 66 93 93

Standard air flow (Fan unit) m3/h 2400 3000 6060 6180

Sound pressure level, Cooling dB(A) 47 48 49 51

Operating range, Cooling/Heating °C 15~43

Out door unit Standard model (RAV-) SP564ATP-SG SP804ATP-SG SP1104AT-SG SP1404AT-SG

Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E

Cooling*1

Capacity kW 4.8 5.8 9.7 11.2

Range, min-max kW 1.2-5.6 1.9-8.0 2.6-12.0 2.6-14.0

Power consumption kW 1.27 1.37 2.25 2.95

Power supply 1-phase 50Hz 230V (220–240V) / 1-phase 60Hz 220V

Performance dataSDI-Super Digital Inverter

04

Page 5: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

SDI Super Digital Inverter 2HP : Outdoor unit drawings

SDI Super Digital Inverter 3HP : Outdoor unit drawings

Discharge guide mounting hole

(4-dia.4.5 embossing)

charge port Earth terminal

Discharge guard

B legs

A legsDrain hole

(Lon

g ho

le p

itch

For

anc

hor

bolt)

(2-dia. 20x88 long hole)

Drain hole(dia. 25)

2-dia. 11-14 U-shape hole

(For dia.8-10 anchor bolts)Refrigerant pipeconnecting port(dia. 12.7 flare at gas side)

Refrigerant pipeconnecting port(dia. 6.4 flare at liquid side)

8-dia. 6 hole

2-dia. 11xL14 long hole

For fixing outdoor unit

(For dia. 8-10 anchor bolts)

dia.

hole

pitc

h

8

35 52

550

21

669.5 147

32 500

780

71

25

22

257483

108

600 90

54108 125

157 79

31 143

145

21

449

483

30

60 30

27

290

306

320

137

93

342

54

Mounting bolt hole(dia. 12x17 long hole)

Details ofA legs

Mounting bolt(dia. 12x17 U-shape hole)

Details of B legs

40 40

12

17.5

365

17.5

Drain hole(dia. 20x88)

7411

812

8 Air inletport

3802006 0

Air inletport

Air outletport

Drain hole(dia. 25)

B legs

46 34 170

75

70383150 600

A legs 3996

320

30

2

1

890

24

4001518018

9555

94

2

1

255

247

155

1880135

90055052

Refrigerant pipeconnecting port(dia. 9.5 flare at liquid side)

Refrigerant pipeconnecting port(dia. 15.9 flare at gas side)

9555

17817817860

32768 518

83 7

765

9555

12 64

1

1

2

Knockout for downward piping

Z views

Refrigerant piping holeIndoor/Outdoor unitconnecting wire inlet hole

Name Note

581

534

148

165

(Unit: mm)

Ø38 Knockout holePower supply inlet hole

05

Page 6: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

06

(Unit: mm)

SDI Super Digital Inverter 4&5HP : Outdoor unit drawings

06

Page 7: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

6

*Made In Japan

*Applicable to certain models

07

Page 8: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Toshibaoperations

Toshiba Air Conditioning main

production facilities are based in Japan

and Thailand.

Toshiba Carrier Corporation Japan

Toshiba’s Fuji Works is the base for

development of products that employ

the latest in advanced air conditioner

technologies.

The factory is blessed to be situated

such that it looks out on the magnifi cent

natural beauty of Mt. Fuji, Japan’s

tallest and most impressive mountain,

and a symbol by which the nation is

recognized.

Since commencing operations in

1943, Toshiba Fuji Works has been the

birthplace of many excellent products,

including the world’s fi rst split-type duct

free air conditioner, and the world’s

fi rst inverter split-type (duct free) air

conditioner.

The factory is currently home to

development and production of air

conditioners for both residential and

commercial customers: the compressors

that serve as an air conditioner’s heart,

and the advanced inverters, a core

component that adopts Toshiba’s most

advanced technologies.

Toshiba Carrier Thailand Corporation

Located in Pathumthani, approximately

40 km from Bangkok, is the base for

the production of a wide range of

Toshiba residential and light commercial

products incorporating the latest

technologies in energy effi ciency.

Since the factory started its operations

in 1989, the company has earned a

signifi cant number of quality, safety and

environmental certifi cations.

Toshiba air conditioners from Thailand

factory are distributed in more than 50

countries around the world.

Introduction

08

Page 9: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Excellent Energy Effi ciency Ratio

3.59* 3.55* 3.54*3.21*

gy

09

Page 10: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Toshiba Digital Inverter for Economy and EcologyThe Toshiba Digital Inverter air conditioners combine economy and ecology in a

compact body. They feature state-of-the-art technology, fl exible control, and easy

installation to bring natural comfort and convenience to any business environment.

With a wide selection of indoor units to suit your commercial applications,

Toshiba Digital Inverter is certainly the economical and ecological way

to go!

Innovative Inverter Technology

The innovative inverter technology is the heart of Toshiba

Digital Inverter that achieves high power and high effi ciency

simultaneously.

When Toshiba Digital Inverter is switched on, the inverter

control, assisted by PAW (Pulse Amplitude Modulation), rapidly

reaches the desired temperature by increasing compressor

frequency. When the desired temperature has been attained,

the inverter control uses PWM (Pulse With Modulation) to

adjust compressor rotation speed to effi ciently maintain

precise temperature control without consuming excess power.

By adopting this innovative inverter technology, Toshiba

Digital Inverter off ers remarkable energy-saving control,

effi cient economical operation, and excellent comfort.

010

Page 11: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Optimum Comfort

Toshiba Digital Inverter’s inverter technology maintains precise

control of room temperature and creates a comfortable

enviroment.

In conventional units, the compressor switches off once the

set temperature is reached, and switches on again after the

temperature drops. The time it takes for the unit to switch on

and off causes the room temperature to greatly fl uctuate.

With Toshiba Digital Inverter, the inverter control reduces

the compressor power once the desired temperature has

been reached, but continues operating at a reduced state to

maintain a stable room temperature with minimal fl uctuations.

By putting and end to on/off compressor operation, the

inverter technology also allows Toshiba Digital Inverter to

signifi cantly reduce noise levels.

Inverter Air conditioners for

Offi ces, Showrooms, Restaurants,

Other Light Commercial and Household Applications

011

Page 12: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Innovative Outdoor Units

DC twin rotary compressor

Brushless Dccompressor motor

Small and lightweight - With the adoption of refrigerant

R410, Toshiba Digital Inverter outdoor units now boast an ultra

compact and lightweight design for easy and convenient installation.

Easy Installation - In addition to being small and light weight, Toshiba Digital

Inverter’s outdoor units are fi tted with a smaller diameter piping than conventional

models. This means easier installation, shorter installation time and lower installation cost.

With vector IPDU control, noise emitted from the drive unit its greatly reduced by changing the motor current wave to a smooth sinusoidal pattern.

RAV-SM563AT-SGRAV-SM803AT-SG

RAV-SM1103AT-SGRAV-SM1403AT-SG

Technology - Toshiba Digital Inverter’s outdoor units are

equipped with a rotary compressor and IPDU (Intelligent Power Drive

Unit) for high reliability, high effi ciency and low noise.

Various Indoor unit combination - Toshiba Digital Inverter outdoor units are compatible with a selection of indoor

units to match a broad range of applications. Please consult Sales Department for more information.

High-wall TypeDuct Type Ceiling Type Cassette

012

Page 13: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Energy-Savings and Economy

Effi cient energy use — Toshiba Digital Inverters’

powerful yet highly effi cient inverter technology features

energy-saving operation that reduces annual power

consumption by as much as 40% compared to conventional

units.

The variable power levels of the compressor allows Toshiba

Digital Inverter to evenly maintain the room temperature so

that less energy is wasted. Moreover, without the surging

on and shutting off of the compressor in conventional units,

Toshiba Digital inverter can operate as low as 1.5kW*, saving a

bundle of energy.

* In the case of cooling and heating capacity of the Digital Inverter 2HP 4-Way

Cassette Type unit.

Superior COP — In terms of COP (Coeffi cient of

Performance), all Toshiba Digital Inverter models greatly

exceed the standard level.

Toshiba Digital Inverter adopts environmentally-safe, non-

ozone depleting R410A refrigerant, used for the fi rst time in

commercial air conditioners.

R410A refrigerant — In order to meet strict restrictions on the

production of equipment that uses the R22 refrigerant used in

most of commercial air conditioners today, R410A refrigerant

was judged the most appropriate for Toshiba Digital Inverter

units to contribute to environmental preservation.

R410A R407C

Ozone depletion potential (ODP) 0 0

Refrigerant capability

(*comparison with R22)

147% 100%

Pressure loss

(*comparison with R22)

56% 106%

Conventional type

Ecologically-Sustainable

Digital Inverter

013

Page 14: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

The Powerful Benefi ts of Digital Inverter

1. Revolutionary ‘Digital Inverter’ technology assures

reduced annual power consumption (up to 40%)

over conventional ‘fi xed speed’ units.

2. The indoor ambient conditions are maintained more

uniformly at desired settings, in spite of variations in

indoor or outdoor load conditions,

3. Year round comfort conditions with the automatic

switch – over of Heating & Cooling mode in all types

of Digital Inverter Indoor units.

4. Longer piping lengths which can cater to various site

conditions.

5. Ecologically sustainable, Non-ozone Depleting

R410A refrigerant used in all units.

6. Fully featured cordless remote available for all types

of indoor units.

7. Group control and Central remote control options

available for all units.

8. Systems are compatible to link up with Toshiba

Super MMS and Mini SMMS systems used for large

installations

9. Compact indoor & outdoor units with smallest foot

print sizes. Easier & effi cient to deliver & install.

10. Low starting current (<1Amp) reduces cost of power

back ups & electrical accessories.

DI Digital Inverter

High-wall Type

Duct Type

Cassette Type

Ceiling Type

014

Page 15: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

NEW

NEW

Line up

DI Series

2HP 3HP 4HP 5HP

RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

4-way Cassette Type

RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E

High-wall Type

RAV-SM566KRT-E RAV-SM806KRT-E – –

Duct Type

RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E

Ceiling Type

RAV-SM567CTP-E RAV-SM8077CTP-E RAV-SM11047CTP-E RAV-SM14047CTP-E

NEW

NEW

015

Page 16: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Temperature conditioning

Individual Louvre Control

The angles of each of the four louvres can be set individually

Δ Enables airfl ow to be chosen according to user’s preferences.

Easy installation

The panel is attached using the

bolt that is already installed on the

indoor unit.

4-way Cassette Type

Models

RAV-SM564UT-E

RAV-SM804UT-E

RAV-SM1104UT-E

RAV-SM1404UT-E

Panels

RBC-U31PG(W)-E

RBC-U31PG(W)-E

Wireless remote

controller kit

RBC-AX32U(W)-E

Inverter Allows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.

Individual louvre control Enables airfl ows to be chosen according to user’s preferences.

Auto-turn LouvresAir outlet grilles move automatically to fi ll every corner of the room with warm or cool air.

Automatic Air Volume ControlDepending on the diff erence between the room temperature and the set temperature, switches automatically between High, Low and Very Low.

Long- life FilterBuilt-in long-life fi lter makes maintenance easier.

Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.

Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.

DryGradually dehumidifi es the room to create even greater comfort.

Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit fi lter.

Limit Timer Uses a 168-hour timer with three modes – “On timer”, “OFF timer” and “Repeat OFF timer”.

Cooler Compatible with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C

Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)

Comfort Operativity Installation

23 28

2,050 mm

4,500 mm

6,300 mm

Horizontal face750 mm

Mode : coolingLouvre position : horizontalFan speed : Hi

Vertical face

(C)

Three louvre swing patterns

Note: Need to set from wired remote controller

(1) Standard swing (2) Diagonally opposite swing (3) Turn-around

wing

NEW

*Wired remote controller (Optional)

016

Page 17: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

1. combination

type 4way cassette 4way cassette (with twin kit)

system-type DI DI DI DI DI DI

indoor-type 4way 4way 4way 4way 4way 4way

capacity hp 2.0 3.0 4.0 5.0 2.0 3.0

indoor RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM564UTP-E RAV-SM804UTP-E

Qty-indoor unit 1 1 1 1 2 2

outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

controller (wireless) RBC-AX31U(W)-E

cooling capacity-rated kW 5.1 6.1 9.7 12.5 5.1 6.1

cooling capacity-range kW <1.5 - 5.6> <1.5 - 8.0> <3.0 - 11.2> <3.0 -13.2> < 1.5 - 5.6 > < 1.5 - 8.0 >

cooling power input-rated kW 1.42 1.72 2.74 3.74 1.42 1.72

NEA tick tick √√ √√ √√ √ √√ √

running current (230V) A 6.54 8.14 12.53 16.8 6.54 8.14

fl are connection main pipe (gas) mm 12.7 15.9 15.9 15.9 12.7 15.9

fl are connection main pipe (liquid) mm 6.4 9.5 9.5 9.5 6.4 9.5

pipe length (min) m 5 5 5 5 5 5

pipe length (max) m 30 30 50 50 30 30

chargeless length m 20 20 30 30 20 20

brand kit RBC-TWP30E2 RBC-TWP50E2

2. indoors

model name RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM564UTP-E × 2 RAV-SM804UTP-E × 2

indoor 4way 4way 4way 4way 4way 4way

capacity hp 2.0 3.0 4.0 5.0 2.0 3.0

air fl ow-H m3/h 1,050 1,230 2,010 2,100 1,050 1.230

air fl ow-M m3/h 870 960 1,440 1,440 870 960

air fl ow-L m3/h 780 810 1,170 1,230 780 810

sound pressure level (L)/(M)/(H) dB 28 / 29 / 32 28 / 31 / 35 33 / 38 / 43 34 / 38 / 44 28 / 29 / 32 28 / 31 / 35

dimension (H X W X D) mm 256 × 840 × 840 256 × 840 × 840 319 × 840 x 840 319 × 840 × 840 256 × 840 × 840 256 × 840 × 840

weight kg 20 20 24 24 20 20

panel model name RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U321PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E

panel dimension (H × W × D) mm 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950

panel weight kg 4.2 4.2 4.2 4.2 4.2 4.2

fan type turbo fan turbo fan turbo fan turbo fan turbo fan turbo fan

fan motor W 14 20 68 72 14 20

air fi ller Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter

attached remote controller (wireless) RBC-AX32U(W)-E

power input-max(for name Plate) W 40 40 120 120 40 40

3. outdoor

model name RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

outdoor-type DI DI DI DI DI DI

capacity hp 2.0 3.0 4.0 5.0 4.0 5.0

phase 1 1 1 1 1 1

power supply V 230 230 230 230 230 230

power supply (Hz) Hz 50 50 50 50 50 50

air-fl ow m3/hr 2,400 2,700 4,500 4,500 4,500 4,500

sound pressure level dB 46 48 53 54 53 54

dimension (H × W × D) mm 550 × 780 × 290 550 × 780 × 290 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320

weight kg 38 44 77 77 77 77

compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary

fan motor output kw 43 43 100 100 100 100

Refrigerant Quantity in Outdoorunit kg 1.0 1.7 2.8 2.8 2.8 2.8

Additional refrigerant charge g/m 20 40 40 40 40 40

power input-max(for NamePlate) kw 2.49 3.41 4.75 4.87 4.75 4.87

installation fuse rating A 16 16 25 25 25 25

power wire mm2 1.5 1.5 2.5 2.5 2.5 2.5

indoor/outdoor connecting wire mm2 1.5 1.5 1.5 1.5 1.5 1.5

017

Page 18: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Features

With its attractive, slim-line design, this unit is best suited for restaurants and other applications

where elegance is required. The fi ltration system further improves the indoor air quality benefi ts

of this high-wall unit.

Key features

With its slim design, this compact and stylish unit blends into any room setting.

Enhanced fi ltration system: Zeolite Plus + Sasa fi lter to deodorise, Bio-Enzyme fi lter

+ Gingko fi lter to purify and a new antioxidant Vitamin C fi lter.

Auto-louvre mode allows optimum air distribution throughout the room.

A wireless controller is included.

a TCC Link remote control is optional.

High-wall Type

Inverter

Allows step-less regulation

of the air-conditioner’s

power, which reduces

energy consumption and

improves comfort.

Auto-turn Louvres

Air outlet grilles move

automatically to fi ll every

corner of the room with

warm or cool air.

Automatic Air Volume

Control

Depending on the

diff erence between the

room temperature and the

set temperature, switches

automatically between

High, Low and Very Low.

Comfort Operativity Installation

Hot Start

When using the heater for

preheating or defrosting,

stops the indoor fan to

prevent cold air from

being blown into the

room.

Automatic Cooling/

Heating

Automatically switches

between cooling and

heating mode.

Dry

Gradually dehumidifi es

the room to create even

greater comfort.

On/Off Timer

The operation start and

stop times can be set with

a digital clock

Cooler Compatible with

an Outdoor Temperature

of - 15°C

Stable cooler operation is

possible when the outdoor

temperature is as low as

-15°C

Models

RAV-SM566KRT-E

RAV-SM806KRT-E

Wireless remote

controller

WH-L11SE

018

Page 19: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

1. combination

type Hi Wall Hi Wall (with Twin Kit)

system-type DI DI DI DI

indoor-type high wall high wall high wall high wall

capacity hp 2.0 3.0 2.0 3.0

indoor RAV-SM566KRT-E RAV-SM806KRT-E RAV-SM566KRT-E RAV-SM806KRT-E

Qty-indoor unit 1 1 2 2

outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-E RAV-SM1403AT-E

cooling capacity-rated kW 5.1 6.1 5.1 6.1

cooling capacity-range kW < 1.5 - 5.6 > < 1.5 - 8.0 > < 1.5 - 5.6 > < 1.5 - 8.0 >

cooling power input-rated kW 1.42 1.74 1.42 1.74

NEA tick tick √√ √√ √√ √

running current (230V) A 6.54 8.14 6.54 8.14

fl are connection main pipe (gas) mm 12.7 15.9 12.7 15.9

fl are connection main pipe (liquid) mm 6.4 9.5 6.4 9.5

pipe length (min) m 5 5 5 5

pipe length (max) m 30 30 30 30

chargeless length m 20 20 20 20

branch kit RBC-TWP30E2 RBC-TWP50E2

2. indoors

model name RAV-SM566KRT-E RAV-SM806KRT-E RAV-SM566KRT-E × 2 RAV-SM806KRT-E × 2

indoor-type high wall high wall high wall high wall

capacity hp 2.0 3.0 2 3

air fl ow-H m3/h 840 1,020 840 1,020

air fl ow-M m3/h 750 750 750 750

air fl ow-L m3/h 660 660 842 660

sound pressure level (L) / (M) / (H) dB 36 / 39 / 42 36 / 41 / 47 36 / 39 / 42 36 / 41 / 47

dimmension (H × W × D) mm 320 × 1050 × 228 320 × 1050 × 228 320 × 1050 × 228 320 × 1050 × 228

weight kg 12 12 12 12

fan type cross fl ow fan cross fl ow fan cross fl ow fan cross fl ow fan

fan motor output W 30 30 30 30

air fi lter Attached Attached Attached Attached

attached remote controller (wireless) WH-L11SE WH-L11SE WH-L11SE WH-L11SE

power input-max(for NamePlate) W 50 70 50 70

3. outdoors

model name RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

outdoor-type DI DI DI DI DI

capacity hp 2.0 3.0 4 5

phase 1 1 1 1 1

power supply v 230 230 230 230

power supply (Hz) Hz 50 50 50 50

air fl ow m3/h 2,400 2,700 4,500 4,500

sound pressure level dB 46 48 53 54

dimension (H × W × D) mm 550 × 780 × 290 550 × 780 x 290 795 × 900 × 320 795 × 900 × 320

weight kg 38 44 77 77

compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary

fan motor output W 43 43 100 100

Refrigerant Quantity in Outdoorunit kg 1.0 1.7 2.8 2.8

Additional refrigerant charge g/m 20 40 40 40

power input-max(for NamePlate) kw 2.49 3.41 4.75 4.87

installation fuse rating A 16 16 25 25

power wire mm2 1.5 1.5 2.5 2.5

indoor/outdoor connecting wire mm2 1.5 1.5 1.5 1.5

019

Page 20: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Wide range of applications

The use of ducts allows air outlets to be conveniently installed anywhere on the ceiling,

eliminating the conspicuous presence of the air conditioner in the center of the room. Not only

can this be applied to a wide variety of layouts from narrow spaces to polygonal rooms; it also

greatly improves the aesthetics of a room with its unobtrusive presence.

Polygonal rooms Narrow rooms Rooms with fi xtures and

obstacles

High static pressure

External static pressure can be raised as high as 120pa (max), so that all

areas of the room can be reached for even temperature distribution, no matter how complex the

layout.

High-lift drain pump

The fl exible piping layout is made possible by an optionally available drain-pump kit that raises

the drain piping up to 27 cm from the drain port.

New slimmer chasis with higher static pressure

Reduce from 320mm to 275mm height.

Versatile and Clever

Duct Type

Inverter

Allows step-less regulation

of the air-conditioner’s

power, which reduces

energy consumption and

improves comfort.

Automatic Air Volume Control

Depending on the diff erence

between the room

temperature and

the set temperature,

switches automatically

between High, Low

and Very Low.

Long-life Filter

Built-in long-life fi lter

makes maintenance easier

Hot Start

When using the heater for

preheating or defrosting,

stops the indoor fan to

prevent cold air from

being blown into the

room.

Automatic Cooling/

Heating

Automatically switches

between cooling and

heating mode.

Dry

Gradually dehumidifi es

the room to create even

greater comfort.

Filter Sign

Automatic displays on

the remote controller say

when to perform

maintenance for the

indoor unit fi lter.

Limit Timer

Uses a 168 hour timer with

three modes — “ON timer”,

“OFF timer” and “Repeat

OFF timer”

Cooler Compatible with

an Outdoor Temperature

of - 15°C

Stable cooler operation is

possible when the outdoor

temperature is as low as

-15°C

Built-in Drain Pump

The built-in drain pump

makes draining easier (in

the celling cassette type, it

is built in to the main unit.)

Comfort Operativity Installation

Models

RAV-SM566BTP-E

RAV-SM806BTP-E

RAV-SM1106BTP-E

RAV-SM1406BTP-E

Wired remote

controller

RBC-AMT32E

*Wireless remote controller (Optional)

020

Page 21: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

1. combination

type Standard ducted Standard ducted (with Twin Kit)

system-type DI DI DI DI DI DI

indoor-type duct duct duct duct duct duct

capacity rank hp 2.0 3.0 4.0 5.0 2.0 3.0

indoor RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM566BTP-E RAV-SM806BTP-E

Qty-indoor unit 1 1 1 1 2 2

outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

controller (wired) RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

cooling capacity-rated kW 5.1 6.1 9.7 12.5 5.1 6.1

cooling capacity-range kW < 1.5 - 5.6 > < 1.5 - 8.0 > < 3.0 - 11.2 > < 3.0 - 13.2 > < 1.5 - 5.6 > < 1.5 - 8.0 >

cooling power input-rated kW 1.42 1.72 2.74 3.74 1.42 1.72

NEA tick tick √√ √√ √√ √ √√ √

running current (230V) A 6.54 8.14 12.53 16.8 6.54 8.14

fl are connection main pipe (gas) mm 12.7 15.9 15.9 15.9 12.7 15.9

fl are connection main pipe (liquid) mm 6.4 9.5 9.5 9.5 6.4 9.5

pipe length (min) m 5 5 5 5 5 5

pipe length (max) m 30 30 50 50 30 30

chargeless length m 20 20 30 30 20 20

branch kit RBC-TWP30E2 RBC-TWP50E2

2. indoors

model name RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM566BTP-E × 2 RAV-SM806BTP-E × 2

indoor-type duct duct duct duct duct duct

capacity hp 2.0 3.0 4.0 5.0 2.0 3.0

air fl ow-H m3/h 800 1,200 2,100 2,100 N.A N.A

air fl ow-M m3/h 630 930 1,650 1,650 N.A N.A

air fl ow-L m3/h 480 720 1,260 1,260 N.A N.A

sound pressure level (L)/(M)/(H) dB 25 / 29 / 33 26 / 30 / 34 33 / 36 / 40 33 / 36 / 40 25 / 29 / 33 26 / 30 / 34

dimmension (H × W × D) mm 275 × 700 × 750 275 × 1000 x 750 275 × 1400 × 750 275 × 1400 × 750 275 × 700 × 750 275 × 1000 × 750

weight kg 23 30 40 40 40 40

external static pressure (std) Pa 40 40 40 40 40 40

external static pressure (upper) Pa 120 120 120 120 120 120

external static pressure (lower) Pa 30 30 30 30 30 30

fan type centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan

fan motor output 120 120 120 120 120 120

air fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter

attached remote controller (wired) RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

power input-max(for NamePlate) w 150 150 250 250 150 150

3. outdoors

model name RAV-SM563AT-SG RAV-SM803AT-SG RASV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

outdoor-type DI DI DI DI DI DI

capacity rank hp 2.0 3.0 4.0 4.0 5.0 5.0

phase 1 1 1 1 1 1

power supply v 230 230 230 230 230 230

power supply (Hz) Hz 50 50 50 50 50 50

air fl ow m3/h 2,400 2,700 4,500 4,500 4,500 4,500

sound pressure level (cooling) dB 46 48 53 54 53 54

dimension (H × W × D) mm 550 × 780 × 290 550 x 780 × 290 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320

weight kg 38 44 77 77 77 77

compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary

fan motor output kw 43 43 100 100 100 100

Refrigerant Quantity in Outdoor unit kg 1.0 1.7 2.8 2.8 2.8 2.8

Additional refrigerant charge g/m 20 40 40 40 40 40

power input-max(for NamePlate) kw 2.49 3.41 4.75 4.87 4.75 4.87

installation fuse rating A 16 16 25 25 25 25

power wire mm2 1.5 1.5 2.5 2.5 2.5 2.5

indoor/outdoor connecting wire mm2 1.5 1.5 1.5 1.5 1.5 1.5

021

Page 22: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Comfortable ambience

Quietest in industryA new design has been adopted that greatly reduces the noise level to half that of conventional

units. Operation is always whisper-quiet.

Flap controlThe airfl ow angle is automatically set to the most suitable setting according to your cooling or

heating needs, and an automatic swing mode enables airfl ow to reach all areas of the room to

create a comfortable ambience.

Installation effi ciency

Suspending the unit from the ceiling saves the trouble of complex installation procedures. It

can be suspended simply by adjusting two screws on the intake grill. Compared to conventional

units which involve a dozen screws, installation is further simplifi ed.

Quiet and Comfortable

Ceiling Type

Models

RAV-SM567CTP-E

RAV-SM807CTP-E

RAV-SM1107CTP-E

RAV-SM1407CTP-E

Wired remote

controller

RBC-AMT32E

*Wireless remote controller (Optional)

Inverter

Allows step-less regulation

of the air-conditioner’s

power, which reduces

energy consumption and

improves comfort.

Automatic Air Volume

Control

Depending on the

diff erence between the

room temperature and

the set temperature,

switches automatically

between High, Low and

Very Low.

Long-life Filter

Built-in long-life fi lter

makes maintenance easier

Comfort Operativity Installation

Hot Start

When using the heater for

preheating or defrosting,

stops the indoor fan to

prevent cold air from

being blown into the

room.

Auto-turn Louvers

Air outlet grilles move

automatically to fi ll every

corner of the room with

warm or cool air.

Dry

Gradually dehumidifi es

the room to create even

greater comfort.

Filter Sign

Automatic displays on

the remote controller say

when to perform

maintenance for the

indoor unit fi lter.

Limit Timer

Uses a 168 hour timer with

three modes — “ON timer”,

“OFF timer” and “Repeat

OFF timer”

Cooler Compatible with

an Outdoor Temperature

of - 15°C

Stable cooler operation is

possible when the outdoor

temperature is as

low as -15°C

Built-in Drain Pump

The built-in drain pump

makes draining easier (in

the celling cassette type, it

is built in to the main unit.)

In cooling

mode, the fl ap

automatically

swings between

the top three

positions

In heating

mode, the fl ap

automatically

swings between

all fi ve positions.

123

45

30˚30˚

123

45

60˚60˚

022

Page 23: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

1. combination

type Under ceiling Under ceiling (with Twin Kit)

system-type DI DI DI DI DI DI

indoor-type ceiling ceiling ceiling ceiling celling celling

capacity hp 2.0 2.0 4.0 5.0 2.0 3.0

indoor RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM567CTP-E RAV-SM807CTP-E

Qty-indoor unit 1 1 1 1 2 2

outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

controller (wired) RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

cooling capacity-rated kW 5.1 6.1 9.7 12.5 5.1 6.1

cooling capacity-range < 1.5 - 5.6 > < 1.5 - 8.0 > < 3.0 - 11.2 > < 3.0 - 13.2 > < 1.5 - 5.6 > < 1.5 -8.0 >

cooling power input-rated kW 1.42 1.72 2.74 3.74 1.42 1.72

NEA tick tick √√ √√ √√ √ √√ √

running current (230V) A 6.54 8.14 12.53 16.8 6.54 8.14

fl are connection mian pipe (gas) mm 12.7 15.9 15.9 15.9 12.7 15.9

fl are connection main pipe (liquid) mm 6.4 9.5 9.5 9.5 6.4 9.5

pipe length (min) m 5 5 5 5 5 5

pipe length (max) m 30 30 50 50 30 30

chargeless length m 20 20 30 30 20 20

branch kit RBC-TWP30E2 RBC-TWP50E2

2. indoors

model name RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM567CTP-E × 2 RAV-SM807CTP-E × 2

indoor-type celling celling celling celling celling celling

capacity rank hp 2.0 3.0 4.0 5.0 2.0 3.0

air fl ow-H m3/h 900 1,410 1,860 2,040 900 1,410

air fl ow-M m3/h 720 1,002 1,350 1,530 720 1,002

air fl ow-L m3/h 540 750 1,020 1,200 540 750

air-fl ow-H m3/min 15.0 23.5 31.0 34.0 15.0 23.5

air-fl ow-M m3/min 12.0 16.7 22.5 25.5 12.0 16.7

air-fl ow-L m3/min 9.0 12.5 17.0 20.0 9.0 12.5

sound pressure level (L)/(M)/(H) dB 28/35/37 29/36/41 32/38/44 35/41/46 28/35/37 29/36/41

dimmension (H × W × D) mm 235 × 950 × 690 235 ×1,270 × 690 235 × 1,586 × 690 235 × 1,586 × 690 235 × 950 × 690 235 × 1,270 × 690

weight kg 23 29 35 35 23 29

fan type centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan

fan motor output W 94 94 139 139 94 94

air fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter

attached remote controller (wired) RBC-AMT32-E RBC-AMT32-E RBC-AMT32-E RBC-AMT32-E BBC-AMT32-E BBC-AMT32-E

power input-max(for NamePlate) W 94 94 150 150 94 94

3. outdoors

model name RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG

outdoor-type DI DI DI DI DI DI

capacity rank 2.0 3.0 4.0 5.0 4.0 5.0

phase 1 1 1 1 1 1

power supply v 230 230 230 230 230 230

power supply (Hz) 50 50 50 50 50 50

air fl ow m3/h 2,400 2,700 4,500 4,500 4,500 4,500

sound pressure level (cooling) dB 46 48 53 54 53 54

dimension (H × W × D) mm 550 × 780 × 290 550 × 780 × 290 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320

weight kg 38 44 77 77 77 77

compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Ratory DC Twin Ratory

fan motor output kw 43 43 100 100 100 100

Refrigerant Quantity in Outdoor unit kg 1.0 1.7 2.8 2.8 2.8 2.8

Additional refrigerant charge g/m 20 40 40 40 40 40

power wire mm2 1.5 1.5 2.5 2.5 2.5 2.5

indoor/outdoor connecting wire 1.5 1.5 1.5 1.5 1.5 1.5

023

Page 24: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Z view

155

28.5

6157

64

187

32

Bottom face of ceiling

Knockout for fresh

air intake dia.150

300 or less

Sta

nd

-up

66

1 o

r le

ss*

Stan

d-u

p 8

50 o

r le

ss

Bottom face of ceiling

Bottom face

of ceiling

Drain-up standing-up size

860 to 910 Ceiling open dimension

860

to 9

10 C

eilin

g o

pen

dim

ensi

on

Ceiling panel (Sold separately)

Refrigerant pipe connecting port (Gas side)

Refrigerant pipe connecting port (Liquid side)

Hanging bolt M10 orW3/8 local arrange

Drain discharge port

For branch duct knockout square hole 150 (diam.)

For branch duct knockout square hole

150 (diam.) (Also located on the back)

*( ): 110–140 type

12

9

132 2

56

30

101

16.5

351

480

256.5

196.5

38435 105

223.5

163.5

7774

105

(18

3)

*1

20

*(1

37

)

*(3

19

)

1000 or more 1000 or more

15

or

mo

re

15

or

mo

re

10

00

or

mo

re

Space required for installation

241.5

263

397.5

12

9

18

9

337.5

30

105

72 106.5

17

2

112

44

157

Wiring connection port

Z 45

95

0 P

an

el e

xte

rna

l dim

en

sio

n

78

0 H

an

gin

g b

olt

pit

ch

416.5

408

690 20 Hanging bolt pitch

950 Panel external dimension

26

9

32

3

Electric parts box

HIGHWALL

RAV-SM566KRT-E

Ceiling

RAV-SM806KRT-E

56 type

80 type

120 to 140 type

ACapacity class

855

1125

1540

910

1180

1595

B

(mm)

B

(Ha

ng

ing

p

osi

tio

n)

A (Hanging position)

Refrigerant pipe (Gas side)

Wireless sensor mounting section

Piping hole on the wall (dia.100 hole)

Drain pipe connecting port

Air intake port dia.92 *(Duct sold separately)

Drain left piping extake port *

Remote controller cable intake port *

Remote controller cable intake port *

Piping extake port *

Drain port VP20

(Inner dia.62, hose supplied)

Power supply intake port *Refrigerant pipe (Liquid side)

17

03

20

84

128

Left drain size

Remote controller piping intake port *

Power supply cable intake port *

Upper piping extake port *

110 50

130

216

146

75 97

76

53

70

135

17

1

90

32

92

14

5

347

3284

262

Z view

Space required for installation and servicing

(Front side to bepositioned horizontally)

250 or more

250 or more

500

or

mo

re

Ceiling surface

Unit

Wit

hin

50

Hanging bolt

68

0

167105

114

141

210

20

0 (

Liq

uid

pip

e)

21

6 (

Ga

s p

ipe

) * : Knockout hole

Z

Indoor units4-way cassette

Unit: mm

024

Page 25: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

RAV-SM806BTP-E

DUCT

RAV-SM566BTP-E

Outdoor units Unit: mm

RAV-SM1106BTP-E

RAV-SM1406BTP-E

025

Page 26: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

RAV-SM563AT-SG~RAV-SM803AT-SG

RAV-SM1103AT-SG~RAV-SM1403AT-SG

Refrigerant pipe connecting port (Gas side)

Refrigerant pipe connecting port (Liquid side)

Refrigerant pipe connecting port (Gas side)

Hanger (both sides)

Refrigerant pipe connecting port (Liquid side)

8-dia.6 hole (for fixing outdoor unit)

Charging port

Mounting bolt hole

(2-dia.12x17 U-shape cut-out)

Mounting bolt hole

(2-dia.12x17 long hole)

Drain hole dia.25

(An

cho

r b

olt

lo

ng

ho

le

pit

ch)

(An

chor

bol

t lo

ng

hol

e p

itch

)

(dia

.6 h

ole

p

itch

)

B leg part

A leg part

B leg part

A leg part

Air outlet

Air inlet Drain hole (dia.25)

DI110~140 type

Drain hole (dia.20x88)

Knock out

(for drain)

Knockout(for drain)

Knockout for lower piping

Air

in

let

2-dia.11x14 long hole

(for dia.8–10 anchor bolt)

2-dia.11x14 U-shape cut-out

(for dia.8–10 anchor bolt)2-dia.20x88 drain long hole

2-dia.6 hole

Detailed A leg part

Detailed A leg part

Detailed B leg part

Detailed B leg part

Fan guard

2-dia.6 hole

60

30

20

30

54

600

108 125

9038

54

R5.5

R15

14769.5 21

55

0

48

3

32

0

30

6

29

0

63

5

44

9

36

51

7.5

17

.5

13

7

93

528 500

483

108

257

32

25

22

71

780

38

54

R5.5

R15

11

145

342

157 79

21

14331

54

36 (43)

95

52

600

29 90 20191

150

602621

40

21

70

(47

)

39

43

40

900

314550

270

43

95

39

47

17

.5

40

40

28

17

.5

320

50

25

Z view

Z300

56

51

01

307

60

96

27

B

C

6067

15

4 D E

254

518

53

42

50

86 7

58

7

27 58

46

161

400

B

B

F G

C

C60

25

90

89

79

5

16

5

60

8026

4

Air inlet

Air outlet

Air

inle

t

Space required for service

150 or more

150 or more500 or more

300 or more

DI

B

C

Power supply wiring hole dia.38 knockout hole

56–140 typeName

Piping drawing port

Outdoor units Unit: mm

026

Page 27: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Remote ControllersToshiba Digital Inverters operated with an easy-to-use remote controller.

Indoor unit 4-Way Cassette Ducted Under Ceiling High-WallRAV-SM**4UTP-E RAV-SM**6BTP-E RAV-SM**7CTP-E RAV-SM**6KRT-E

Remoto controller RBC-AX32U(W)-EWireless remote controller kit *RBC-AX32CE2Wireless remote controller kit *TCB-AX32E2Wireless remote controller kit * *RBC-AMS51E-ENLite-Vision plus remote controller * * * *RBC-AMT32EWired remote controller * * * *RBC-EXW21EWeekly timer * * * *TCB-SC642TLE2Central remote controller * * * *

Note: To link to CRC Control, a net adapter interface card is required - model TCB-PCNT30TLE2

027

Page 28: Toshiba_Digital Inverter System 24pp A4_MCV11.indd

Cost Saving

Comfort

An effi cient use of time

TCC-SDI 2016/05