17
Thermal Vacuum Power TVP Applied to Industrial Process Heat January 2017 2012 AWARD INNOVATIVE ENTERPRISE

TVP Applied to Industrial Process Heat - TVP Solar - … - TVP Applied to...TVP Applied to Industrial Process Heat January 2017 2012 AWARD INNOVATIVE ENTERPRISE Solar Heat For Industrial

Embed Size (px)

Citation preview

Thermal Vacuum Power

TVP Applied to Industrial Process Heat

January 2017

2012 AWARD

INNOVATIVE ENTERPRISE

Solar Heat For Industrial Process Heat (SHIP) Applications

2

Solar thermal directly drives heat-intensive applications through 200°C + pre-heating

Boilers

Steam Machines

Drying Machines

Solar thermal panel design: Mirrorless, flat geometry with high-vacuum insulation Panel features: Corrosion-proof all-metal casing Embedded return HTF flow under high-vacuum Spot-Check™ visual vacuum verification 100% recyclable

TVP directly serves applications: Thermal fluid up to 180°C, 14 bar directly or via heat exchanger, minimizing electricity or combustible consumption. Supports steam applications integrating an indirect steam generator

TVP target industries include: Pharmaceuticals Textiles Food & Beverage Oil & Gas

Chemical Pulp & Paper Hospitals Industrial Laundry

TVP SHIP: System Strengths & Uniqueness

Game-changing value proposition for industrial processes with TVP panels

Minimizes fossil fuel consumption Substitutes & cuts diesel and other fossil fuels burned, running thermal process via solar with combustible auxiliary. Highly relevant to regions with limited distribution networks and remote locations with associated high cost and scarcity of fuels

Best solar solution for dusty, hazy, polluted, humid & overcast environments Any solar field output is affected by light conditions and further reduced by particulate accumulation on collector surfaces. Uniquely, TVP panels require no water-based cleaning in these environments, because high vacuum insulation enables effective capture of full-spectrum diffuse light.

Flexible to match any client need in any weather condition

Boiler/steam generator hybridization via an integrated auxiliary burner allows maximum solar use in any weather condition. SHIP can be configured to serve new machinery and integrated into existing systems mainly via heat exchanger.

Scalable in terms of capacity and solar contribution TVP-based solar field modularity and scalability in absorption chiller capacity meets cooling needs of any client. Solar contribution o thermal requirements uniquely can be further scaled and extended over daylight operations via thermal storage.

3

Significantly reduce CO2 emissions

TVP replaces diesel and fossil fuels directly, immediately reducing carbon dioxide and other pollutant emissions. SHIP thus not only reduces operating costs but also allows adopters to achieve sustainability goals, both corporate and international.

TVP SHIP: Indirect Boiler Heating For Large Capacity

Solar-only SHIP model – typically for pre-heating or heating

4

Electricity or combustible consumption is minimized by the addition of a solar field sending hot fluid (pressurized water or diathermic oil) to a heat exchanger and serving a boiler with integrated heater (resistance or burner).

This configuration maximizes the use of solar energy, taking advantage of any temperature generated by the solar field during daylight hours, as pre-heating booster or complete heat provider.

Solar thermal contribution to thermal requirements depends on solar field size.

TVP SHIP: Direct Boiler Heating For Large Capacity

Solar-only SHIP model – typically for pre-heating or heating

5

Electricity or combustible consumption is minimized by the addition of a solar field sending hot fluid (pressurized water or diathermic oil) directly to a boiler with integrated heater (resistance or burner).

This configuration maximizes the use of solar energy, taking advantage of any temperature generated by the solar field during daylight hours, as pre-heating booster.

Solar thermal contribution to SHIP requirements depends on solar field size.

TVP SHIP: Steam Generation For Large Capacity Up To 150 psi

Solar + combustible hybrid SHIP model via indirect steam generator (ISG) for steam applications

6

Solar energy complemented by a natural gas, LPG, diesel, biogas or biomass burner, provides steam up to 24/7 at required pressure via an indirect steam generator. The burner provides additional lift between solar field thermal generation and temperature required by an indirect steam generator.

This configuration maximizes the use of solar energy, because the steam generator takes advantage of any temperature generated by the solar field during daylight hours.

Solar thermal contribution to SHIP requirements depends on solar field size and related thermal storage capacity (which can extend solar use over daylight hours).

TVP SHIP: Serving Heat Exchangers

Solar-only or hybrid mode to heat or pre-heat application fluids

7

TVP SHIP: Cascade Configuration For Multiple Needs

One field, multiple heat services

8

• Two or three applications supplied from the same solar thermal source • separate applications requiring a maximum delta-T of 30°C • each thermal loop can serve a different application machine • steam, heating, and cooling needs served simultaneously

• The cascade system optimizes the economics of the applications: • single investment for multiple energy savings • single installation footprint for multiple energy demands

• Cascade configuration: • one solar field provides thermal energy above the highest required temperature • each application is a separate, closed loop to ensure system integrity • optional combustible burner for 24/7 operation and/or constant temperature supply

Proven breakthrough panel performance: reliable energy output and no need for cleaning Installed and operational in KSA , UAE and Kuwait since 2012

Save fossil fuel and cut CO2 emissions, in particular during peak hours Invest in the only source of energy which can provide payback on system CAPEX

Integrated as add-on, contributes but does not affect existing boiler/heater operations

Stabilize energy bills over 20 years and industrial cost of the products GCC have a highly volatile energy market in terms of prices, significant further increases expected

Minimize dependence on electricity (in particular at peak hours) and diesel supply

Game changing value proposition well suited for industrial process heat needs

TVP SHIP Value Proposition

TVP SHIP Value Proposition

10

Game changing value proposition well suited for industrial process heat needs

Proven breakthrough panel performance: reliable energy output with no water-based cleaning needed

Directly compete with fossil fuels and replace electricity and combustibles (diesel, LNG, SNG, PNG)

Minimize dependence on fossil fuel supply, especially in remote and off-network areas

Secure thermal energy costs over 20 years and offset highly volatile energy market prices

Significantly cut CO2 emissions to comply with sustainability goals & corporate social responsibility plan

Integrate solar with new machinery or retrofit existing systems without impeding existing operations

Thermal Vacuum Power

Send us a project and application machine specs

TVP will supply a detailed feasibility study including:

• Preliminary solar field design

• Simulated energetics

• Budget quotation

• Economic analysis

email: [email protected]

For the first time ever, TVP combines high-vacuum insulation and planar layout in solar thermal offering high performance at highly competitive cost!

Collecting both direct & diffuse light allows TVP panels to operate with high efficiency at high temperatures without concentration or continuous aiming

Glass Plate

Heat Absorber

Fluid Pipe

Glass Support Structure

High-Vacuum Insulation

Breakthrough technology for solar thermal operates up to 200°C

Thermal Vacuum Power Charged™ Panels

TVP - Certified Best Performance

13

TVP’s MT-Power is the First Solar Thermal Panel Certified up to 200°C Under SolarKEYMARK

Highest performance at any operating temperature, in any light condition, for every thermal application

Key advantages vs concentrators: (i) highest solar-to-thermal conversion efficiency (mainly due to diffuse light capture); (ii) lowest cost profile; (iii) long-lasting durability; (iv) maintenance-free: no cleaning or repair to mechanical parts (no tracking systems); (v) easy architectural integration; (vi) stackable for lower transportation costs.

TVP Unique Feature: No Cleaning

Operates consistently in extreme diffuse light conditions without cleaning

2217 1988 1957

79%

63% 55%

21% 37%

45%

0

500

1000

1500

2000

2500

Riyadh Kuwait City Abu Dhabi

Total Irradiance Direct Diffuse

TVP captures both direct and diffuse light

kWh

/m2/y

ear

Source: Meteonorm

No cleaning is required by TVP panels Dust accumulation only affects TVP efficiency up to 20%

Source: TVP, IEA SHC

Dust accumulation increases sunlight scattering (diffuse)

-20%

-15%

-10%

-5%

0%

5%

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

Jul-

14

Au

g-1

4

Sep

-14

Oct

-14

No

v-1

4

Dec

-14

Jan

-15

Feb

-15

Mar

-15

Ap

r-1

5

May

-15

Jun

-15

Effi

cie

ncy

Lo

ss

KW

hth

/m2

/day

Irradiance Energy output never-cleaned panel Dust Effect

Never Cleaned Panel in Operations

15

Minimal Effect On Performance From Dust Accumulation

May 12th before cleaning

2,44kWhth with 5.95 kWhth (40% efficiency) Peak panel operating temperature 164°C

Peak ambient temperature 43,6°C

May 13th after dry-cleaning

2,73kWhth with 5.71 kWhth (47% efficiency) Peak panel operating temperature 176°C

Peak ambient temperature 47,5°C

TVP panels show unique diffuse light capturing

Only 14% performance difference!!!

16

Dry cleaning (with a cloth or a brush) is sufficient for TVP panels

Thermal Vacuum Power Charged TM panels are designed to operate at high temperature MT-Power panels deliver (up to 200°C) without concentrators or mirrors

Ideally suited for high ambient temperature environments The higher the ambient T°, the higher the panel efficiency

Captures diffuse light making panels ideal for dusty & hazy environments Uses up to 40% more light in Gulf region than other technologies!

Removes power demand from the grid Peak performance highly correlated with peak demand

Minimal or no cleaning and maintenance Thanks to diffuse light capturing, cleaning is not necessary and can be done at customer option Works automatically and independently, has a web-based remote control system

Efficiently utilize available space Requires minimal footprint Easy architectural integration: can be deployed on any walkable rooftop (50kg bearable load)

Game changing technology well suited for Gulf region:

Key Advantages