36
User Installation Instruction Manual AU INTEC 30 COMBI INTERNAL Wall mounted combi boiler

User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

  • Upload
    others

  • View
    14

  • Download
    1

Embed Size (px)

Citation preview

Page 1: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

User Installation Instruction Manual

AU INTEC 30 COMBI

INTERNAL Wall mounted

combi boiler

Page 2: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

Immergas S.p.A. declines all liability due to printing or transcription errors, reserving the right to make any modifications to its technical and commercial documents without forewarning.

Dear Client,Our compliments for having chosen a top-quality Hunt Heating/Immergas product, able to assure well-being and safety for a long period of time, you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your boiler. Read the following pages carefully; you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm your satisfaction for our product.For any interventions or routine maintenance contact Hunt Heating for Authorised Service Personal.

General recommendationsAll Immergas products are protected with packaging suitable for transport.

The material must be stored in dry environments and protected from bad weather.

The instruction book is an integral and essential part of the product and must be consigned to the new user also in the case of transfer or succession of ownership.

It must be stored with care and consulted carefully, as all of the warnings provide important safety indications for installation, use and maintenance stages.

This instruction booklet contains technical information on how installing Immergas boilers. For other issues related to installation of boilers (i.e.: safety in work sites, environment protection, injury prevention), comply with the laws in force and technical standards.

In compliance with legislation, the systems must be designed by qualified professionals, within the dimensional limits established by the Law. Installation and maintenance must be performed in compliance with the regulations in force, according to the manufacturer’s instructions and by qualified professionals.

Improper installation or assembly of Immergas appliance and/or components, accessories, kit and devices can cause unexpected problems to persons, animals and objects. Read the provided product instructions carefully in order to install the product correctly.

Maintenance must be carried out by Authorised Service Personal.

The appliance must only be destined for the use for which it has been expressly declared. Any other use will be considered improper and therefore potentially dangerous.

If errors occur during installation, operation and maintenance, due to non compliance with technical laws in force, standards or instructions contained in this book (or however supplied by the manufacturer), the manufacturer is excluded from any contractual and extra-contractual liability for any damages and the appliance warranty is invalidated.

IntroductionThe Immergas range of standard efficiency boilers are wall mounted, fan assisted, room-sealed boilers. The burner is let electronically and the heat output is controlled by a modulating gas valve.The INTEC 30 COMBI INTERNAL are heating and Domestic Hot Water boilers.The boilers are supplied with a pump, pressure relief valve, expansion vessel and pressure gauge fully assembled and tested.They are suitable for Natural Gas and Universal LPG.

IMPORTANTIt is the law that all gas appliances are authorised persons and registered technician in accordance with local laws and AS/NZS 5601 and AS/NZS 3500 A.

This appliance meets the requirements of IPX5D.Failure to install this appliance correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the law is complied with.

Manufacturerís instructions must NOT be taken in anyway as over-riding statutory obligations.

NOTEThe Boilers MUST only be used with Immergas Condensing flue components.THIS BOILER IS NOT SUITABLE FOR POOL OR SPA HEATER UNLESS CONNECTED TO A SUITABLE APPROVED HEAT EXCHANGER.Hydronic System (Australia) Pty Ltd PO Box 294 Braeside VIC 3195.

On conformity to AS4552 -2005 and AS 3498.

Page 3: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

INDEXUSER pageINSTALLER page MAINTENANCE TECHNICIAN page

1 Boiler installation ...................................... 41.1 Installation recommendations. ................ 41.2 Main dimensions. ...................................... 51.3 Anti-freeze protection. ............................. 51.4 connections. ............................................... 51.5 Remote control (CARv2) (Optional). .......61.6 External probe (Optional). ...................... 61.7 Immergas flue systems. ............................. 71.8 Tables of resistance factors

and equivalent lengths. ............................. 71.9 Horizontal concentric kit installation. ... 91.10 Vertical concentric kit installation. .......101.11 System filling. ...........................................111.12 Gas system start-up. ................................111.13 Boiler start up (ignition). .......................111.14 Circulation pump. ...................................111.15 Boiler components. .................................12

2 Instructions for use and maintenance. .132.1 Cleaning and maintenance. ...................132.2 General warnings. ...................................132.3 Control panel. ..........................................132.4 Using the boiler........................................132.5 Fault and anomaly signals. .....................142.6 Information menu. ..................................162.7 Boiler shutdown ......................................162.8 Restoring central heating system

pressure. ....................................................162.9 Draining the system. ...............................162.10 Anti-freeze protection. ...........................162.11 Case cleaning. ..........................................162.12 Decommissioning. ..................................16

3 Boiler commissioning (initial check). ..173.1 Hydraulic Diagram. ................................173.2 Wiring diagram. ......................................183.3 Troubleshooting. .....................................193.4 Converting the boiler

to other types of gas. ...............................193.5 Calibration of number of fan revs. ........193.6 Adjustment of the air-gas ratio. .............193.7 Checks following conversion to another

type of gas. ................................................193.8 Programming the P.C.B. .........................203.9 “Chimney sweep” function. ...................223.10 Pump anti-block function. .....................223.11 Radiators anti-freeze function. ..............223.12 P.C.B. periodical self-check. ...................223.13 Automatic vent function. .......................223.14 Casing removal. .......................................223.15 Variable heat power. ................................233.16 Yearly appliance check

and maintenance. ....................................243.17 Combustion parameters. ........................243.18 Technical data. .........................................253.19 Exploded boiler diagram. .......................263.20 Spare part list. ..........................................273.21 Boiler registration. ..................................283.22 Commissioning boiler check list. ..........293.23 Service records. ........................................30

Page 4: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

4

M

PD

W

I

j

jj

h

h

kk

h

f

c

a

c

e e

d

kg

Tb T

g

T

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

1-1

1 BOILER INSTALLATION

1.1 INSTALLATION RECOMMENDATIONS.

The INTEC 30 COMBI INTERNAL boiler has been designed uniquely for wall-installation, for the heating of rooms for domestic use.- installation (according to the legislation and

technical standards in force);- maintenance operations (including those

scheduled, periodical, ordinary and special);- removal (to the outdoors in a place suitable

for loading and transporting appliances and components) as well as any replacement with equivalent appliances and/or components.

The wall surface must be smooth, without any protrusions or recesses enabling access to the rear part. They are not designed to be installed on plinths or floors (Fig. 1-1).By varying the type of installation the classification of the boiler also varies, precisely:- Type C boiler Uses concentric or Coaxial pipes

systems Hunt Heating supplies the correct flue for this application.

Only professional ly heat ing/plumbing technicians are authorised to install Immergas gas appliances.Installation must be carried out according to regulation standards AS/NZS 5601 or Local Authority laws.Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding gases with a greater density and be installed to meet all local and AS/NZS 5601 LAWS. Before installing the appliance, ensure that it is delivered in perfect condition; if in doubt, contact the supplier

immediately. Packing materials (staples, nails, plastic bags, polystyrene foam, etc.) constitute a hazard and must be kept out of the reach of children. Leave adequate space above the boiler for possible water and flue removal connections. Keep all flammable objects away from the appliance (paper, rags, plastic, polystyrene, etc.). Do not place household appliances underneath the boiler as they could be damaged if the safety valve intervenes (if not conveyed away by a draining funnel), or if there are leaks from the connections; on the contrary, the manufacturer cannot be held responsible for any damage caused to the household appliances. In the event of malfunctions, faults or incorrect operation, turn the appliance off immediately and contact a qualified technician (e.g. Hunt Heating Service Dept which has specifically trained staff and original spare parts). Do not attempt to modify or repair the appliance alone.Failure to comply with the above implies personal responsibility and invalidates the warranty.

Installation Standards: - Installations MUST comply with AS/NZS

5601 and Local laws. Use AS/NZS 5601 as a guide for specific locations see below.

- Installation is prohibited on the vertical projection of the cooking surface.

- Installation is also prohibited in places/environments that constitute common parts of office condominiums such as stairs, cellars, entrance halls, attics, lofts, escape routes, etc. if they are not located inside technical compartments under the responsibility of each individual building and only accessible to the user (for the features of the technical compartments, see the technical standards in force).

YES NO

Attention: wall mounting of the boiler must guarantee stable and efficient support for the boiler.The plugs (standard supply) are to be used only in conjunction with the mounting brackets or fixing template to fix the appliance to the wall; they only ensure adequate support if inserted correctly (according to technical standards) in walls made of solid or semi-hollow brick or block. In the case of walls made from hollow brick or block, partitions with limited static properties, or in any case walls other than those indicated, a static test must be carried out to ensure adequate support.

N.B.: the hex head screws supplied in the blister pack are to be used exclusively to fix the relative mounting bracket to the wall.

These boilers are used to heat water to below boiling temperature in atmospheric pressure.They must be attached to a heating system suit-able for their capacity and voltage.

1-2

Flue terminal positionsUse as a guide only. Refer to AS/NZS 5601 or gas fitting rules for specific location.

D - DoorI - Mechanical air inletM - Gas meterT - Flue TerminalW - Window

Ref. Item Min. Clearance mm

a Below eaves, balconies and other projections (Appliances over 50MJ/h) 300

b From the ground, above a balcony or other surface 300

c From a return wall or external wall 300

d From a gas meter 1000

e From an electricity meter or fusebox/breaker panel 500

f From a drain pipe or soil pipe 75

g Horizontally from any building structure or obstruction facing a flue terminal 500

h From any other flue terminal, cowl or combustion air intake 300

j Horizontally from any opening window, door, non-mechanical air inlet or other opening into a building with the exception of sub-floor ventilation 300

k From a mechanical air inlet including a spa blower 1000

n Vertically below an opening window, non-mechanical air inlet or any other opening into a building with the exception of sub-floor ventilation 500

• The location of the flue terminal must comply with the clear-ances shown on this page.

If you are unsure about clearances not indicated here, in general refer to AS/NZS 5601 or your local autority.

• All measurements are the minimum clearances required.• Terminals must be positioned so to aviod combustion products

entering the building.

Flue terminal positions. Shaded area indicates prohibited area

Page 5: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

5

1-3

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

1.2 MAIN DIMENSIONS.

minimum temperature required for preserving the system.

The boilers is made from materials that are resistant to ethylene and propylene glycol-based anti-freeze liquids.For life and possible disposal, follow the supplier's instructions.- Protect the condensate drain trap and circuit

board against freezing by using an accessory that is supplied on request (anti-freeze kit) comprising two electric heating elements, the relevant cables and a control thermostat (carefully read the installation instructions contained in the accessory kit pack).

Boiler anti-freeze protection is thus ensured only if:- the boiler is correctly connected to gas and

electricity power supply circuits and powered;- the anti-freezing kit components are efficient.In these conditions the boiler is protected against freezing to temperature of -15°C.The warranty does not cover damage due to inter-ruption of the electrical power supply and failure to comply with that stated on the previous page.

N.B.: if the boiler is installed in places where the temperature falls below 0°C the domestic water and heating attachment pipes must be insulated.

1.4 CONNECTIONS.Gas connection.Our boilers are designed to operate with NG and Universal LPG. Supply pipes must be sized correctly to relevant gas codes. Before connecting the gas line, carefully clean inside all the supply pipes to remove any residue that could impair boiler efficiency. Also make sure the gas corresponds to that for which the boiler is prepared (see boiler data-plate). If different, the appliance must be converted for operation with the other type of gas (see converting appliance for other gas types). The dynamic gas supply (NG or Universal LPG) pressure must also be checked according to the type used in the boiler, which must be in compliance, as insufficient levels can reduce boiler output and cause malfunctions.Ensure correct gas isolation valves connection. The gas supply pipe must be suitably dimensioned according to current regulations in order to guarantee correct gas flow to the burner in conditions of maximum boiler.

N.B.: there is a special adhesive label inside the built-in frame displaying the layout of the boiler connections.

Fuel gas quality. The appliance has been designed to operate with gas free of impurities; otherwise it is advisable to fit special filters upstream from the appliance to restore the purity of the gas.

Cold Water connection.Attention: Filling the system, Hunt Heating recommends the use of Auto fill valves sold as an optional extra.

Attention: in order not to void the warranty before making the boiler connections, carefully clean the heating system on the primary heat exchanger (pipes, radiators, etc.) with special cleaning products (Fernox) to remove any deposits that could compromise correct boiler operation.

Chemical treatment of the heating system water is required, in compliance with the technical standards in force, in order to protect the system and the appliance from deposits (e.g., lime scale), slurry or other hazardous deposits. Products like Fernox are suitable for this appliacation. Use of backflow devices are maditory when using chemicals/water treatments or alternatively, ensure physical air break.

Heating Water connections must be made using approved valves this helps with maintenance and servicing. Hunt Heating can provide valves as optional extras.

The boiler safety valve outlet must be connected to a Tun Dish or Directly to a suitable overflow outlet.

1.3 ANTI-FREEZE PROTECTION.Minimum temperature -5°C. The boiler comes standard with an anti-freeze function that activates the pump and burner when the system water temperature in the boiler falls below 4°C.The anti-freeze function is only guaranteed if:- the boiler is correctly connected to gas and

electricity power supply circuits;- the boiler is powered constantly;- the boiler is not in no ignition block (Par. 2.5);- the boiler essential components are not faulty.In these conditions the boiler is protected against freezing to an environmental temperature of -5°C.

Minimum temperature -15°C. If the boiler is installed in a place where the temperature falls below -5°C and in the event there is no gas, or the boiler goes into ignition block, the appliance may freeze.To prevent the risk of freezing follow the instructions below:- Protect the central heating circuit from

freezing by introducing a good quality anti-freeze liquid (specifically for central heating systems), (Fernox), carefully following the manufacturer's instructions regarding the percentage necessary with respect to the

Key: G - Gas supply (not supplied as standard) D - Domestic hot water outlet (not supplied

as standard) C - Domestic cold water inlet (not supplied

as standard) R - System return (not supplied as standard) F - System delivery (not supplied as stand-

ard) SC - Condensate drain (supplied as standard)

(minimum internal diameter Ø13 mm)

Height (mm)

Width (mm)

Depth (mm)

750 440 300CONNECTIONS

GAS DOMESTIC HOT WATER SYSTEM

G D C R F3/4” 1/2” 1/2” 3/4” 3/4”

Page 6: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

6

1-51-4

Position of the central heating temperature user adjustment

45

31

58

Position of the central heating temperature user adjustment

1-71-6

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

Condensate drain. To drain the condensate produced by the appliance, it is necessary to connect to the sewer system by means of acid condensate resistant pipes i.e. p.v.c. having an internal diameter of at least 13 mm. The system connecting the appliance to the drainage system must be carried out in such a way as to prevent freezing of the liquid contained. Connections must comply with national and local regulations on discharging to waste waters, condensate must not discharge to storm water. Pipes must be on gradient to drain.

N.B.: fill the trap with water before operating the boiler.

Electrical connection: The “INTEC 30 COMBI INTERNAL” boiler has an IPX5D protection rating for the entire appliance. Electrical safety of the appliance is reached only when it is correctly connected to an efficient earthing system as specified by current safety standards.

Attention: Immergas/Hunt Heating declines any responsibility for damage or physical injury caused by failure to connect the boiler to an efficient earth system or failure to comply with the reference standards.

Also ensure that the electrical installation corresponds to maximum absorbed power specifications as shown on the boiler data-plate. The boilers come complete with a 1.5 metre power cable that includes an Australian electrowelded plug. The plug is of type I, compliant with standard AS 3112. The power cable must be connected to a 240V ±10% / 50Hz mains respecting L-N polarity and the earth connection . When replacing the power supply cable, contact a qualified technician (e.g. Hunt Heating Service Dept) (Fig. 1-4).In the event of mains fuses replacement on the connection board, use 3.15A fast fuses. For the main power supply to the appliance, never use adapters, multiple sockets or extension leads.Note: If the condensate cannot be on gradiant to drain, a condensate drain can be purchased from Hunt Heating.

1.5 REMOTE CONTROL (CARV2) (OPTIONAL).

The boiler is prepared for the application remote control CARV2, which is available as optional kit (Fig. 1-5).Immergas remote control CARV2 is connected with 2 wires only. Carefully read the user and assembly instructions contained in the acces-sory kit.

• In addition to the functions described in the previous point, the CAR panel V2 enables the user to control all the important information regarding operation of the appliance and the heating system with the opportunity of easily intervening on the previously set parameters without having to go to the place where the appliance is installed. The CARV2 panel is equipped with self-diagnosis to display any boiler functioning abnormalities. The climate chrono-thermostat incorporated into the remote panel enables the system flow temperature to be adjusted to the actual needs of the room being heated, in order to obtain the desired room temperature with extreme precision and therefore with evident saving in running costs. The chrono-thermostat is fed directly by the boiler by means of the same 2 wires used for the transmission of data between boiler and chrono-thermostat.

Comando Amico Remoto remote control (CARV2) (Optional). The operations described below must be performed after having removed the voltage from the appliance. Any CARV2 must be connected by means of terminals IN+ and IN- (on the CARV2 terminal plate).

Attention: if the Comando Amico RemotoV2

(CARV2) remote control is used, arrange two separate lines in compliance with current regulations regarding electrical systems. No boiler pipes must ever be used to earth the electric system or telephone lines. Ensure elimination of this risk before making the boiler electrical connections (ALL ELECTRICAL CONNECTION MUST MEET ALL LOCAL REGULATIONS).

1.6 EXTERNAL PROBE (OPTIONAL).The boiler is prepared for the application of the external probe (Fig. 1-6), which is available as an optional kit. Refer to the relative instruction sheet for positioning of the external probe.The probe can be connected directly to the boiler electrical system and allows the max. system flow temperature to be automatically decreased when the external temperature increases, in order to adjust the heat supplied to the system according to the change in external temperature. The external probe always operates when connected, regardless of the presence or type of room chrono-thermostat used and can work in combination with Immergas chrono-thermostats. The correlation between system flow temperature and external temperature is determined by the position of the selector switch on the boiler control panel according to the curves shown in the diagram (Fig. 1-7). The electric connection of the external probe must be made on clamps 38 and 39 on the boiler P.C.B. (Fig. 3-2).NB: Thermostat connections if using own after market thermostat, after removing manufacturers link, connect to terminals 40 and 41 (Fig. 3-2).

POWER SUPPLY CABLE

Page 7: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

7

1-8

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

(A)

(B)

1.7 IMMERGAS FLUE SYSTEMS.Immergas supplies various solutions separately from the boilers regarding the installation of air intake terminals and flue extraction, which are fundamental for boiler operation.

Attention: the boiler must be installed exclusively with an original Immergas “Green Range” air intake and fume extraction system in plastic, as envisioned by Standard in force.

The plastic pipes cannot be installed outdoors, for tracts longer than 40 cm, without suitable protection from UV rays and other atmospheric agents.

This system can be identif ied by an identification mark and special distinctive marking bearing the note: “only for condensing boilers”.

• Resistance factors and equivalent lengths. Each flue component has a Resistance Factor based on experimental tests and specified in the table below. The Resistance Factor for individual components is independent from the type of boiler on which it is installed and has a dimensionless size. It is however, conditioned by the temperature of the fluids that pass through the pipe and therefore, varies according to applications for air intake or flue exhaust. Each single component has a resistance corresponding to a certain length in metres of pipe of the same diameter; the so-called equivalent length, obtained from the ratio between the relative Resistance Factors. All boilers have an experimentally obtainable maximum Resistance Factor equal to 100. The maximum Resistance Factor allowed corresponds to the resistance encountered with the maximum allowed pipe length for each type of Terminal Kit. This information allows calculations to be made to verify the possibility of setting up various flue configurations.

• Positioning of the gaskets (black) for “green range” flue extraction systems. Position the gasket correctly (for bends and extensions) (Fig. 1-8):

- gasket (A) with notches, to use for bends; - gasket (B) without notches, to use for

extensions. N.B.: if necessary, in order to facilitate the cou-

pling, sprinkle the items with ordinary talcum powder.

• Coupling extension pipes and concentric elbows. To install push-fitting extensions with other elements of the flue, proceed as follows: Install the concentric pipe or elbow with the male side (smooth) on the female section (with lip seal) to the end stop on the previously installed element in order to ensure sealing efficiency of the coupling.

Attention: if the exhaust terminal and/or extension concentric pipe needs shortening, consider that the internal duct must always protrude by 5 mm with respect to the external duct.

• N.B.: for safety purposes, do not obstruct the boiler intake-exhaust terminal, even temporarily.

• N.B.: when installing horizontal pipes, a minimum inclination of 3% must be maintained and a section clamp with pin must be installed every 3 metres.

1.8 TABLES OF RESISTANCE FACTORS AND EQUIVALENT LENGTHS.

TYPE OF DUCTResistance

Factor(R)

Equivalent length in m of

concentric pipe Ø80/125

Concentric pipe Ø80/125 m 1 2,1 1

Concentric bend 90° Ø80/125 3,0 1,4

Concentric bend 45° Ø80/125 2,1 1

Terminal complete with concentric horizontal intake-exhaust Ø80/125 2,8 1,3

Terminal complete with concentric vertical intake-exhaust Ø80/125 3,6 1,7

Concentric bend 90° Ø80/125 with inspection 3,4 1,6

Stub pipe with inspection Ø80/125 3,4 1,6

Page 8: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

8

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

TYPE OF DUCTResistance

Factor(R)

Equivalent length in m of concentric pipe

Ø60/100

Equivalent length in m of concentric pipe

Ø80/125

Concentric pipe Ø60/100 m 1Intake and

Exhaust 16.5 m 1 m 2.8

Concentric bend 90° Ø60/100Intake andExhaust 21 m 1.3 m 3.5

Concentric bend 45° Ø60/100Intake and

Exhaust 16.5 m 1 m 2.8

Terminal complete with concentric horizontal intake-exhaust Ø60/100

Intake andExhaust 46 m 2.8 m 7.6

Concentric horizontal intake- exhaust terminal Ø60/100

Intake andExhaust 32 m 1.9 m 5.3

Concentric vertical intake-exhaust terminal Ø60/100

Intake andExhaust 41.7 m 2.5 m 7

Concentric pipe Ø80/125 m 1Intake andExhaust 6 m 0.4 m 1.0

Concentric bend 90° Ø80/125 Intake andExhaust 7.5 m 0.5 m 1.3

Concentric bend 45° Ø80/125Intake andExhaust 6 m 0.4 m 1.0

Terminal complete with concentric vertical intake-exhaust Ø80/125

Intake andExhaust 33 m 2.0 m 5.5

Concentric vertical intake-exhaust terminal Ø80/125 Intake and

Exhaust 26.5 m 1.6 m 4.4

Terminal complete with concentric horizontal intake-exhaust Ø80/125

Intake and Exhaust 39 m 2.3 m 6.5

Concentric horizontal intake- exhaust terminal Ø80/125 Intake and

Exhaust 34 m 2.0 m 5.6

Concentric adapter from Ø60/100 to Ø80/125 with condensate trap Intake and

Exhaust 13 m 0.8 m 2.2

Concentric adapter from Ø60/100 to Ø80/125 Intake and

Exhaust 2 m 0.1 m 0.3

Tables of Resistance Factors and Equivalent Lengths.

Page 9: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

9

1

2

3

45

6

54

31

2

1-9 1-10

C13

C13

1-11 1-12

C13

C13

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

1.9 HORIZONTAL CONCENTRIC KIT INSTALLATION.

Type C configuration, sealed chamber and fan assisted.

The position of the terminal (in terms of dis-tances from openings, overlooking buildings, floor, etc.) must be in compliance with the regulations in force.This terminal can be employed in the following cases, and, moreover, in default of chimneys / flues / functional and appropriate, or adaptable systems for combustion products scavenging, and using low polluting emission boilers (class 5a, according to the in force technical standard):

- “single renovations of independent systems in buildings made of several real estate units”;

- “new installations of single independent heat systems in buildings subjected to conservative works”.

This terminal is connected directly to the outside of the building for air intake and flue exhaust. The horizontal kit can be installed with the rear, right side, left side or front outlet. For installation with frontal outlet, one must use the fixing plate and a concentric bend coupling in order to ensure sufficient space to carry out the tests required by law upon commissioning.

• External grid. Both the Ø 60/100 and Ø 80/125 intake/exhaust terminal, if properly installed, is pleasant to look at on the outside of the build-ing. Make sure that the external silicone wall sealing plate is properly inserted in the wall.

N.B.: for proper system operation the terminal with grid must be installed correctly ensuring that, the “high” indication on the terminal is observed during installation.

Horizontal intake - exhaust kit Ø60/100. Kit assembly (Fig. 1-9): install the bend with flange (2) on the central hole of the boiler, positioning the gasket (1) positioning it with the circular projections downwards in contact with the boiler flange and tighten using the screws preset in the kit. Fit the Ø60/100 (3) concentric terminal pipe with the male end (smooth) to the female end of the bend (2) up to the stop; making sure that the internal and external wall sealing plate have been fitted, this will ensure sealing and joining of the elements making up the kit.

• Extensions for horizontal kit Ø60/100 (Fig. 1-10). The kit with this configuration can be extended up to a max. horizontal distance of 12.9 m including the terminal with grid and ex-cluding the concentric bend leaving the boiler. This configuration corresponds to a resistance factor of 100. In these cases the special exten-sions must be requested.

Immergas also provides a Ø 60/100 simplified terminal, which in combination with its exten-sion kits allows you to reach a maximum exten-sion of 11.9 metres.

Horizontal intake - exhaust kit Ø80/125. Kit assembly (Fig. 1-11): for the installation of kit Ø80/125 the flanged adapter kit must be used to be able to install the flue system Ø80/125. Install the flanged adapter (2) on the central hole of the boiler, positioning the gasket (1) with the circular projections downwards in contact with the boiler flange and tighten using the screws present in the kit. Engage the bend (3) with the male side (smooth) until it is fully home on the adapter (1). Fit the Ø80/125 (5) concentric terminal pipe with the male end (smooth) to the female end of the bend (4) (with lip seal) up to the stop; making sure that the internal (6) and external wall sealing plates (7) have been fitted, this will ensure sealing and joining of the elements making up the kit.

• Extensions for horizontal kit Ø80/125 (Fig. 1-12). The kit with this configuration can be extended up to a max. distance of 32 m including the terminal with grid and excluding the concentric bend leaving the boiler. If ad-ditional components are assembled, the length equivalent to the maximum allowed must be subtracted. In this case the special extensions must be requested.

The kit includes:N° 1 - Gasket (1)N° 1 - Concentric bend Ø60/100 (2)N° 1 - Concentric intake-exhaust terminal Ø60/100 (3)N° 1 - Internal wall sealing plate (4)N° 1 - External wall sealing plate (5)

The adapter Kit includes:N° 1 - Gasket (1) N° 1 - Adapter

Ø80/125 (2)

The Kit Ø80/125 includes:N° 1 - Concentric bend Ø80/125 at

87° (3) N° 1 - Concentric intake-exhaust

terminal Ø80/125 (4) N° 1 - Internal wall sealing plate (5) N° 1 - External wall sealing plate (6)The remaining components of the kit are not to be used

Max. 12900 mm

Max. 12790 mm

Max. 32000 mm

Max. 31956 mm

Page 10: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

10

C33

C33

C33

C33

1-14

1-161-15

7

4 6

5

1

2

3

1

2

3

4

5

6

7

1-13

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

1.10 VERTICAL CONCENTRIC KIT INSTALLATION.

Type C configuration, sealed chamber and fan assisted.

Vertical concentric of intake and exhaust kit. This terminal enables the air intake and the flue exhausts to be directly emitted outside the house in a vertical direction.

N.B.: the vertical kit with aluminium tile enables installation on terraces and roofs with a maximum slope of 45% (approximately 25°) and the height between the terminal cap and half-shell (374 mm for Ø60/100 and 260 mm for Ø80/125) must always be respected.

Vertical kit with aluminium tile Ø60/100. Kit assembly (Fig. 1-13): install the concentric flange (2) on the central hole of the boiler, positioning the gasket (1) with the circular projections downwards in contact with the boiler flange and tighten using the screws present in the kit.Imitation aluminium tile installation: replace the tile with the aluminium sheet (4), shaping it to ensure that rainwater runs off. Position the fixed

half-shell (6) and insert the intake-exhaust pipe (5). Fit the Ø60/100 (3) concentric terminal pipe with the male end (5) (smooth) into the flange (2) up to the stop; making sure that the wall sealing plate has been fitted (3), this will ensure sealing and joining of the elements making up the kit.

Note: when the boiler is installed in areas where very rigid temperatures can be reached, a special anti-freeze kit is available that can be installed as an alternative to the standard kit.• Extensions for vertical kit Ø60/100 (Fig. 1-14).

The vertical kit with this configuration can be extended to a max. straight vertical length of 14.4 m including the terminal. This configuration corresponds to a resistance factor of 100. In this case the special extensions must be requested.

Vertical kit with aluminium tile Ø80/125.Kit assembly (Fig. 1-15): for the installation of kit Ø80/125 the flanged adapter kit must be used to be able to install the flue system Ø80/125. Install the flanged adapter (2) on the central hole of the boiler, positioning the gasket (1) with the circular projections downwards in contact with the boiler

flange and tighten using the screws preset in the kit. Imitation aluminium tile installation: replace the tile with the aluminium sheet (4), shaping it to ensure that rainwater runs off. Position the fixed half-shell (5) on the aluminium tile and insert the intake-exhaust pipe (7). Fit the Ø80/125 concentric terminal pipe with the male end (smooth) to the female end of the adapter (1) (with lip gasket) up to the stop; making sure that the wall sealing plate has been fitted (3), this will ensure sealing and joining of the elements making up the kit.

• Extensions for vertical kit Ø80/125 (Fig. 1-16). The vertical kit with this configuration can be extended to a max. length of 32 m including the terminal. If additional components are assembled, the length equivalent to the maximum allowed must be subtracted. In this case specific extensions must be requested.

The kit includes:N° 1 - Gasket (1)N° 1 - Female concentric flange (2)N° 1 - Wall sealing plate (3)N° 1 - Aluminium tile (4)N° 1 - Int./exhaust concentric pipe

Ø60/100 (5)N° 1 - Fixed half-shell (6)N° 1 - Mobile half-shell (7)

The adapter Kit includes: N° 1 - Gasket (1) N° 1 - Adapter

Ø80/125 (2)

The Kit Ø80/125 includes:N° 1 - Wall sealing plate (3)N° 1 - Aluminium tile (4)N° 1 - Fixed half-shell (5)N° 1 - Mobile half-shell (6)N° 1 - Int./exhaust concentric

pipe Ø80/125 (7)The remaining components of the kit are not to be used

Max

. 144

00 m

m

Max. 45%

Max

. 320

00 m

m

Max. 45%

Page 11: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

11

1-17

A

B

C

D

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

- check activation of the master switch located upstream from the boiler and in the boiler;

- check that the intake/exhaust concentric terminal (if fitted) is not blocked.

The boiler must not be started up even if only one of the checks should be negative.

N.B.: the boiler preliminary check must be carried out by a qualified technician. The conventional boiler warranty is valid as of the date of testing if not commissioned by a qualified technician.

1.14 CIRCULATION PUMP.The “INTEC 30 COMBI INTERNAL” series boilers are supplied with a built-in circulation pump with 3-position electric speed control. The boiler does not operate correctly with the circulation pump on speed one. To ensure optimal boiler operation, in the case of new system it is recommended to use the pump at maximum speed, position 3.

Pump release. If, after a prolonged period of inactivity, the circulation pump is blocked, unscrew the front cap and turn the motor shaft using a screwdriver. Take great care during this operation to avoid damage to the motor.

1.11 SYSTEM FILLING.Once the boiler is connected, proceed with system filling through the arranged filling valve, which must necessarily be connected to the return pipe system and as close as possible to the boiler (Fig. 1-18).Filling is performed at low speed to ensure release of air bubbles in the water via the boiler and heating system vents.The boiler has a built-in automatic venting valve on the circulator. Check if the cap is loose. Open the radiator air vent valves.Close radiator vent valves when only water escapes from them.Close the filling valve when the boiler manometer indicates approx. 1.2 bar.

N.B.: during these operations, turn on the cir-culating pump at intervals by means of the main selector switch on the control panel. Vent the circulation pump by loosening the front cap and keeping the motor running. Only open for a few seconds at a time.

In presence of the automatic filling, the auto fill valve must necessarily be isolated after system is pressurized.

1.12 GAS SYSTEM START-UP.To start up the system, make reference to the Standard: This divides the systems and therefore the start-up operations into three categories: new systems, modified systems, re-activated systems.In particular, for new gas systems:- open windows and doors;- avoid presence of sparks or naked flames;- bleed all air from pipelines;- check that the internal system is properly sealed

according to specifications.

1.13 BOILER START UP (IGNITION).For issue of the Declaration of Conformity provided for by Italian Law, the following must be performed for boiler start-up:- check that the internal system is properly sealed

according to specifications;- ensure that the type of gas used corresponds

to boiler settings;- switch the boiler on and ensure correct

ignition;- make sure that the gas flow rate and relevant

pressure values comply with those given in the manual;

- ensure that the safety device is engaged in the event of gas supply failure and check activation time;

A = Head available to the system at maximum speed with by-pass closed. B = Head available to the system at maximum speed with by-pass open. C = Head available to the system at second speed with by-pass closed. D = Head available to the system at second speed with by-pass open.

Flow rate (l/h)

Hea

d (m

H2O

)

Hea

d (k

Pa)

Head available to the system.

Page 12: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

12

1-18

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

1.15 BOILER COMPONENTS.

G - Gas R - Return F - Flow C - Cold fill D - Domestic hot water outlet

Key: 1 - Condensate drain trap 2 - Gas valve 3 - Domestic hot water probe 4 - Domestic hot water flow switch 5 - System pressure switch 6 - Flow probe 7 - Safety thermostat 8 - Gas nozzle (only Victrix EXA 24) 9 - Venturi 10 - Detection electrode 11 - Condensation module 12 - System expansion vessel 13 - Flue probe 14 - Manual air vent valve 15 - Sample points (air A) - (flue gases F)

16 - Negative signal pressure point 17 - Positive signal pressure point 18 - Heat exchanger safety thermofuse 19 - Burner 20 - Ignition electrode 21 - Air intake pipe 22 - Igniter 23 - Fan 24 - Air vent valve 25 - DHW heat exchanger 26 - Return probe 27 - Boiler pump 28 - 3 bar safety valve 29 - 3-way valve (motorised) 30 - By-pass 31 - System draining valve

Page 13: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

13

2-1

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

2 INSTRUCTIONS FOR USE AND MAINTENANCE.

2.1 CLEANING AND MAINTENANCE.Attention: the heating systems must undergo periodical maintenance (regarding this, see in the section dedicated to the maintenance/Hunt Heating authorised service engineer, relative to “yearly appliance check and maintenance”) and regular combustion and energy efficiency checks in compliance with AS/NZS 5601 and Immergas commissioning procedures.This ensures that the optimal safety, performance and operation of the boiler remain unchanged over time.We recommend your appliance is serviced annually.

2.2 GENERAL WARNINGS.Use of the boiler by unskilled persons or children is strictly prohibited.If temporary shutdown of the boiler is required, proceed as follows:a) drain the heating system if anti-freeze is not

used;b) shut-off all electrical, water and gas supplies.In the case of work or maintenance to structures located in the vicinity of ducting or devices for flue extraction and relative accessories, switch off the appliance and on completion of operations ensure that a qualified Hunt Heating technician checks efficiency of the ducting or other devices.Never clean the appliance or connected parts with easily flammable substances.

Never leave containers or flammable substances in the same environment as the appliance.

• Attention: the use of components involving use of electrical power requires some fundamental rules to be observed:

- do not touch the appliance with wet or moist parts of the body; do not touch it when barefoot;

- the appliance power cable must not be replaced by the user;

- in the event of damage to the cable, switch off the appliance and contact a qualified technician;

- if the appliance is not to be used for a certain period, disconnect the main power switch.

2.4 USING THE BOILER.Before ignition make sure the heating system is filled with water and that the manometer (7) indicates a pressure of 1 ÷ 1.2 bar.- Open the gas cock upstream from the boiler.- Press the button (1) until the display switches

on. At this point, the boiler goes to the state previous to switch-off.

- If the boiler is in stand-by, press the button (1) again to activate it. If this is not the case, go to the next point.

- Press button (2) in sequence and take the boiler

to summer ( ) or winter ( ) position.

• Summer ( ): in this mode the boiler functions only to produce the DHW, the temperature is set via the selector (5) and the

relative temperature is shown on the display via the indicator (14).

• Winter ( ): in this mode the boiler functions both for producing domestic hot water and heating the environment. The temperature of the DHW is always regulated via the selector (5), the heating temperature is regulated via selector (6) and the relative temperature is shown on the display via the indicator (14).

From this moment the boiler functions automatically. With no demand for heat (heating or domestic hot water production) the boiler goes to “standby” function, equivalent to the boiler being powered without presence of flame. Each time the burner ignites, the relative flame present symbol is displayed (10) with relative power scale.

• Operation with Comando Amico Remoto remote control V2 (CARV2) (Optional). If the CARV2 is connected, the ( ) symbol will appear on the display. The boiler regulation parameters can be set via the CARV2 control panel and the reset button (3) remains active on the boiler control panel, along with the switch-off button (1) (“off ” mode only) and the display where the functioning state is shown

Important: if the boiler is put into “off ” mode, the “ERR>CM” connection error symbol will appear on the CARV2. The CAR V2is however powered constantly so as not to loose memorised programs.

• Solar functioning mode ( ). This function is activated automatically if the boiler detects a probe on the DHW inlet (optional) or if the

Key: 1 - Off/Stand-by/On Button 2 - Summer/Winter Button 3 - Reset button 4 - Information buttons 5 - Domestic hot water temperatureselector

switch 6 - Central heating water temperature selector

switch 7 - Boiler manometer

8 - DHW production phase functioning active 9 - Boiler in block does not require release via

“RESET” button 10 - Flame presence symbol and relative power

scale 11 - Functioning in summer mode 12 - Functioning in winter mode 13 - Room central heating active phase func-

tioning

14 - Temperature indicator, boiler info and error codes

15 - Boiler in Stand-by mode 16 - Presence of external connected devices 17 - Solar function active 18 - Functioning with external temperature

probe active (optional) 19 - Boiler connected to remote control V2

(optional) 20 - Not used on this model

2.3 CONTROL PANEL.

Page 14: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

14

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

“Solar ignition delay” parameter is more than 0 seconds.

During a withdrawal, if the outlet water is hot enough, the boiler does not switch on, the DHW withdrawal symbol ( ) appears on the display along with the flashing solar function symbol ( ).

When the water supplied by the solar system is at a temperature lower than that at which the boiler is set, the boiler switches on. At this point, the solar function symbol will stay on without flashing.

• Functioning with optional external probe ( ). In the case of a system with optional external probe, the boiler flow temperature for room central heating is managed by the external probe depending on the external temperature measured (Par. 1.6). The flow temperature can be modified by selecting the functioning curve via the selector switch (6) (or on the CARV2 control panel, if connected to the boiler) selecting a value from “0 to 9”.

With external probe present, the relative symbol (18) will appear on the display. In the central heating phase, if the temperature of the water contained in the system is sufficient to heat the radiators, the boiler can only function with the activation of the pump.

• “Stand-by” mode. Press button (1) in succession until the ( ) symbol appears. The boiler remains inactive from this moment

and the anti-freeze function, pump anti-block function and 3-way and signalling of any anomalies is guaranteed.

N.B.: in these conditions the boiler is considered still powered.

• “Off ” mode. By holding the button (1) down for 8 seconds, the display switches-off and the boiler is off completely. The safety functions are not guaranteed in this mode.

N.B.: in these conditions the boiler is considered still live even if there are no functions active.

• “Automatic vent” mode. Every time power is supplied to the boiler. the system automatic vent function is activated (duration 8 minutes). This function is displayed via countdown signalled by the indicator (14). During this period the DHW and CH functions are not active.

The “automatic vent” can be annulled by pressing the “reset” button (4).

• Display functioning. The display lights up during the use of the control panel, after 15 seconds inactivity, the brightness drops until just the active symbols are displayed. The lighting mode can be varied via parameter t3 in the circuit board customisation menu.

2.5 FAULT AND ANOMALY SIGNALS.The INTEC 30 COMBI INTERNAL boiler signals any anomalies using a code shown on the boiler display (14) according to the follow-ing table.On the remote control, the error code will be displayed by means of the same numeric code represented according to the following example (e.g. CARV2 = Exx).

Error Code Anomaly signalled Cause Boiler status / Solution

01 No ignition block

In the event of request of room central heating or domestic hot water production, the boiler does not switch on within the preset time. Upon appliance commissioning or after extended downtime, it may be neces-sary to eliminate the block.

Press the Reset button (1).

02 Safety thermostat block (overheating)

During normal operation, if a fault causes excessive overheating internally, the boiler goes into overheating block. Press the Reset button (1).

03 Flue safety thermo-stat block

During normal operation, if a fault causes excessive flue gas overheating, the boiler blocks Press the Reset button (1).

04 Contacts resistance block

The P.C.B. detects an anomaly on the gas valve supply. Check the connec-tion. (the anomaly is detected and displayed only in the event of a request). The boiler does not start (1).

05 Flow probe anomaly The board detects an anomaly on the flow NTC probe. The boiler does not start (1).

06 Domestic hot water probe anomaly The board detects an anomaly on the domestic hot water NTC probe.

In this case the boiler continues to produce domestic hot water but not with optimal performance. Moreover, the antifreeze function (1) is restrained.

08 Maximum N° of reset Number of allowed resets that have already performed.

Attention: the anomaly can be reset 5 times consecutively, after which the function in inhibited for at least one hour. One attempt is gained every hour for a maximum of 5 attempts. By switching the appliance on and off the 5 attempts are re-acquired.

10 Insufficient system pressure

Water pressure inside the central heating circuit that is sufficient to guar-antee the correct operation of the boiler is not detected.

Check on the boiler pressure gauge (1) that the system pressure is between 1÷1.2 bar and restore the correct pressure if necessary.

15 Configuration error If the board detects an anomaly or incongruity on the electric wiring, the boiler will not start.

If normal conditions are restored the boiler restarts without having to be reset. Check that the boiler is configured correctly (1).

16 Fan anomaly This occurs if the fan has a mechanical or electrical fault. Press the Reset button (1).

20 Parasite flame block This occurs in the event of a leak on the detection circuit or anomaly in the flame control unit. Press the Reset button (1).

23 Return probe anom-aly The board detects an anomaly on the return NTC probe The boiler does not start (1).

(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Technical After-Sales Service).

Page 15: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

15

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

Error Code Anomaly signalled Cause Boiler status / Solution

24 Push button control panel anomaly The board detects an anomaly on the pushbutton panel If normal conditions are restored the boiler

restarts without having to be reset (1).

25Block due to flue gas temperature gradi-ent intervention

If the board detects a rapid increase in flue gas temperature probably due to a blocked circulating pump or lack of water in the heat exchanger, the boiler shuts down due to the flue gas temperature gradient trip.

Press the Reset button (1).

27 Insufficient circula-tion

This occurs if there is overheating in the boiler due to insufficient water circulating in the primary circuit; the causes can be:

- low system circulation; check that no shut-off devices are closed on the heating circuit and that the system is free of air (deaerated);

- pump blocked; free the pump.

Press the Reset button (1).

29 Flue probe anomaly If the board detects an anomaly on the flue gas probe the boiler will not start The boiler does not start (1).

31 Loss of remote con-trol communication

This occurs 1 minute after communication is lost between the boiler and the remote control.

Power cycle the boiler. If the Remote Control is still not detected on re-starting the boiler will switch to local operating mode, i.e. using the controls on the control panel (1).

36 IMG Bus communi-cation loss

Communication between the various components is interrupted due to an anomaly on the boiler control unit, on the zone control unit or on the IMG Bus.

The boiler does not satisfy the room heating requests (1).

37 Low power supply voltage

This occurs when the power supply voltage is lower than the allowed limits for the correct boiler operation.

If normal conditions are restored the boiler restarts without having to be reset (1).

38 Loss of flame signal

This occurs when the boiler is ignited correctly and the burner flame switches off unexpectedly; a new ignition attempt is performed and if normal conditions are restored, the boiler does not need to be reset (this fault can be checked in the list of errors in the “Information” menu only).

If normal conditions are restored the boiler restarts without having to be reset (1).

43Block due to loss of continue flame signal

This occurs if the ''Flame signal loss'' error occurs many times in a row within a preset period (38).

Press the Reset button, before restarting, the boiler will run a post-ventilation cycle (1).

44

Block for exceeding the maximum accu-mulated time, close gas valve opening

This occurs if the gas valve remains open for longer than required for normal operation, without the boiler switching on. Press the Reset button (1).

45 High ΔT

If the board detects a sudden and unexpected rise in ΔT between the system flow probe and return probe, the boiler limits the burner output to prevent damaging the condensing module; when the correct ΔT has been restored, the boiler returns to normal operation.

Make sure there is water circulating in the boiler, that the pump is configured accord-ing to system requirements and that the return probe works properly (1).

46Low temperature safety thermostat (optional)

During normal operation, if an anomaly causes excessive overheating of the flow temperature in low temperature conditions, the boiler blocks.

In this case, after suitable cooling, it is pos-sible to reset the thermostat (see relative instructions sheet) (1).

47 Burner power limi-tation

Should flue high temperature be detected, the boiler reduces power sup-plied so as not to damage it. (1).

49High temperature bl o ck on return probe

This occurs when the heat exchanger return circuit reaches too high of a temperature.

Make sure that water circulates properly in the boiler and that the three-way valve works properly. To eliminate it, the Reset button (C) must be pressed (1).

(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Technical After-Sales Service).

Page 16: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

16

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

2.6 INFORMATION MENU.By pressing the “Info” button (4), the “Information menu” is activated, which allows to display some boiler functioning parameters.

Press the “Info” button (4) to scroll the various parameters.

To exit the menu, press the “Info” button (4) up to the end of the list, or by pressing the “Reset” button (3) or by waiting for 15 minutes.

With the menu active, the indicator (14) will alternately show the indication of the parameter via the letter “d” plus the number of the parameter that is being displayed and the value

of the parameter itself.

Id Parameter Description

d1 Displays the flame signal (uA x 10 approximate)d2 Displays the primary exchanger output instant heating flow temperatured3 Displays the instant output temperature from the DHW exchangerd4 Displays the values set for central heating setd5 Displays the values set for DHW set

d6 Displays the external temperature (if external probe present)If the temperature is below zero, the value is displayed flashing.

d7 Display the temperature of the inlet DHW (with DHW inlet probe present)d8 Display the temperature of the return probe.

d9 Displays the list of the last five anomalies.(to scroll the list, turn the CH temperature selector (6))

2.7 BOILER SHUTDOWNSwitch the boiler off by pressing the “ ” but-ton, disconnect the onmipolar switch outside of the boiler and close the gas cock upstream of the appliance. Never leave the boiler switched on if left unused for prolonged periods.

2.8 RESTORING CENTRAL HEATING SYSTEM PRESSURE.

Periodically check the system water pressure. The boiler pressure gauge should read a pressure between 1 and 1.2 bar.If the pressure falls below 1 bar (with the circuit cold) restore normal pressure via the valve located at the bottom of the boiler (Fig. 1-18).N.B.: close the cock after the operation.If pressure values reach around 3 bar the safety valve may be activated.

In this case, remove water from an air vent valve of a radiator until reaching pressure of 1 bar, or ask an authorised company for assistance.

In the event of frequent pressure drops, contact qualified staff for assistance to eliminate possible system leakage.

2.9 DRAINING THE SYSTEM.To drain the boiler, use the special system draining valve (Fig. 1-18)Before draining, ensure that the system filling valve is closed.

2.10 ANTI-FREEZE PROTECTION.The boiler has an anti-freeze function that switches on automatically when the temperature falls below 4°C (standard protection to minimum temperature of -5°C). All information relative to the anti-freeze protection is stated in Par. 1.3. In order to guarantee the integrity of the appliance and the domestic hot water heating system in zones where the temperature falls below zero, we recommend the central heating system is protected using anti-freeze liquid and installation of the Immergas Anti-freeze Kit in the boiler. In

the case of prolonged inactivity (second case), we also recommend that:- the electric power supply is disconnected;- the heating circuit and boiler domestic water

circuit must be drained. In systems that are drained frequently, filling must be carried out with suitably treated water to eliminate hardness that can cause lime-scale.

2.11 CASE CLEANING.Use damp cloths and neutral detergent to clean the boiler casing. Never use abrasive or powder detergents.

2.12 DECOMMISSIONING.In the event of permanent shutdown of the boiler, contact an authorised company for the procedures and ensure that the electrical, water and gas supply lines are shut off and disconnected.

Page 17: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

17

3-1

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3 BOILER COMMISSIONING (INITIAL CHECK).

When commissioning the boiler, ensure the appliance checklist, located at the rear of this instruction booklet is completed.To commission the boiler:- ensure that the type of gas used corresponds to

boiler settings recorded on the appliance data plate;

- check connection to a 230V-50Hz power mains, correct L-N polarity and the earthing connection;

- switch the boiler on and ensure correct ignition;- ensure the gas inlet static pressure is correct,

1.5 Kpa;- check that the gas maximum and minimum

relative pressure values correspond to those given in the handbook, Par. 3.16;

- check activation of the safety device in the event of no gas, as well as the relative activation time;

- check activation of the main switch located upstream from the boiler and in the boiler;

- check that the intake and/or exhaust terminals are not blocked;

3.1 HYDRAULIC DIAGRAM.

- check activation of the “no air” safety pressure switch;

- ensure activation of all adjustment devices;- ensure production of domestic hot water (when

the boiler is connected to an external cylinder);- ensure sealing efficiency of hydronic circuits;- check ventilation and/or aeration of the

installation room where provided.

Key: 1 - Condensate drain trap 2 - Domestic hot water flow switch 3 - Flow limiter 4 - Domestic hot water probe 5 - Gas valve 6 - Gas valve outlet pressure point (P3) 7 - Venturi positive sign (P1) 8 - Venturi negative sign (P2) 9 - Air/gas Venturi manifold 10 - Fan 11 - Gas nozzle 12 - Detection electrode 13 - Flue probe 14 - Air intake pipe 15 - Condensation module 16 - Manual air vent valve 17 - Heat exchanger safety thermofuse 18 - Air sample point 19 - ∆p gas pressure point 20 - Flue sample point 21 - Flue hood 22 - Safety thermostat 23 - Flow probe 24 - Ignition electrode 25 - Burner 26 - Condensation module cover 27 - Return probe 28 - System expansion vessel 29 - Air vent valve 30 - Boiler pump 31 - System draining valve 32 - System pressure switch 33 - 3-way valve (motorised) 34 - DHW heat exchanger 35 - By-pass 36 - 3 bar safety valve

G - Gas supply (not supplied as standard) D - Domestic hot water outlet

(not supplied as standard) C - Cold inlet (not supplied as standard) R - System return (not supplied as standard) F - System flow (not supplied as standard) SC - Condensate drain (supplied as standard)

(minimum internal diameter Ø13 mm)

Page 18: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

18

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.2 WIRING DIAGRAM.

3-2

Key: B1 - Flow probe B2 - Domestic hot water probe B4 - External sensor (optional) B5 - Return probe B10 - Flue probe CARV2 - Comando Amico Remoto Version 2

remote control (optional) E1 - Ignition electrode E2 - Detection electrode E4 - Overheating safety thermostat E13 - Exchanger safety thermofuse G2 - Igniter M1 - Boiler pump M20 - Fan M30 - 3-way valve R5 - Trimmer DHW set R6 - Trimmer CH set S2 - Functioning knob S3 - Reset button S4 - Domestic hot water flow switch S5 - System pressure switch S20 - Room thermostat (optional) S31 - On/Stand-by/Off button S33 - Info button T2 - Voltage transformer X40 - Room thermostat jumper Y1 - Gas valve

Storage tank unit: the boiler is prepared for the connection to a storage tank unit, which must be connected to clamps 36 - 37 of the terminal board, eliminating resistance R8.

Comando Amico Remoto remote controlV2: the boiler is prepared for the application of the Comando Amico Remoto remote control (CARV2, which must be connected to clamps 41 and 44 of the terminal board respecting the polarity and eliminating jumper X40.

Room thermostat: the boiler is prepared for the application of the room thermostat (S20), which must be connected to clamps 40 and 41 of the terminal board eliminating jumper X40.

The connector X5 is used for the connection to the relay P.C.B..

The connector X6 is used for the connection to the personal computer.

The connector X8 is used for software updating operations.

Page 19: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

19

3-3

+

+

3

12

1

P1

2

P3

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.3 TROUBLESHOOTING.N.B.: maintenance interventions must be carried out by a qualified technician. Smell of gas. Caused by leakage from gas circuit pipelines. Check sealing efficiency of gas intake circuit.

- Repeated ignition blocks. This may be caused by: incorrect electric power supply, check respect of L and N polarity. No gas, check the presence of pressure in the network and that the gas intake pipe is open. Incorrect adjustment of the gas valve, check the correct calibration of the gas valve. Also check that the heat exchanger or trap are not clogged.

- Irregular combustion or noisiness. This may be caused by: a dirty burner, incorrect combustion parameters, intake-exhaust terminal not correctly installed. Clean the above components and ensure correct installation of the terminal, check correct setting of the gas valve (Off-Set setting) and correct percentage of CO2 in flue gases.

- Frequent activation of the temperature overload thermostat. It can depend on the lack of water in the boiler, little water circulation in the system or blocked pump. Check on the manometer that the system pressure is within established limits. Check that the radiator valves are not closed and also the functionality of the pump.

- Siphon blocked. This may be caused by dirt or combustion products deposited inside. Check, by means of the condensate drain cap, that there are no residues of material blocking the flow of condensate.

- Heat exchanger blocked. This may be caused by the trap being blocked. Check, by means of the condensate drain cap, that there are no residues of material blocking the flow of condensate.

- Noise due to air in the system. Check opening of the hood of the special air vent valve (Fig. 1-18). Make sure the system pressure and expansion vessel pre-charge values are within the set limits; The factory-set pressure values of the expansion vessel must be 1.0 bar, the value of system pressure must be between 1 and 1.2 bar.

3.4 CONVERTING THE BOILER TO OTHER TYPES OF GAS.

If the boiler has to be converted to a different gas type to that specified on the data plate, request the relative conversion kit for quick and easy conversion.Boiler conversion must be carried out by a qualified technician (e.g. Authorised After-Sales Technical Assistance Service).To convert to another type of gas the following operations are required:- remove the voltage from the appliance;- replace the nozzle located between the gas pipe

and gas/air mixing sleeve (Part. 2 Fig. 1-18), taking care to remove the voltage from the appliance during this operation;

- apply voltage to the appliance;- calibrate the number of fan revs. (Par. 3.5):- adjust the correct air/gas ratio (Par. 3.6);- seal the gas flow rate devices (if adjusted);- after completing conversion, apply the sticker,

present in the conversion kit, near the data-plate. Using an indelible marker pen, cancel the data relative to the old type of gas.

These adjustments must be made with reference to the type of gas used, following that given in the table (Par. 3.15).

3.5 CALIBRATION OF NUMBER OF FAN REVS.

Important: verification and calibration is necessary, in the case of transformation to other types of gas, in the extraordinary maintenance phase with replacement of the circuit board, air/gas circuit components or in the case of installations with flue gas extraction systems, with horizontal concentric pipe measuring more than 1 metre.

The boiler heat output is correlated to the length of the air intake and flue exhaust pipes. This decreases with the increase of pipe length. The boiler leaves the factory adjusted for minimum pipe length (1m). It is therefore necessary, especially in the case of maximum pipe extension, to check the ∆p gas values after at least 5 minutes of burner functioning at nominal heat output, when the temperatures of the intake air and exhaust flue gases have stabilised. Adjust the nominal and minimum heat output in the domestic hot water and central heating modes according to the values in the table (Par. 3.15) using the differential manometers connected to the ∆p gas pressure point (16 and 17 Fig. 1-18).

Enter the configurations menu and regulate the following parameters (Par. 3.8):- DHW minimum power output;- DHW maximum power output;- minimum heating output;- maximum central heating output;- ignition power.

3.6 ADJUSTMENT OF THE AIR-GAS RATIO.

Important: the verification operations of the CO2 must be carried out with the casing mounted, while the gas valve calibration operations must be carried out with the casing open and removing the voltage from the boiler.

Calibration of the minimum CO2 (minimum heating power).Enter the chimney sweep phase without withdrawing domestic hot water and take the selector switches to minimum (turn them in an anti-clockwise direction until “0” is seen on the display). to have an exact value of CO2 in the flue gases the technician must insert the sampling probe to the bottom of the sample point, then check that the CO2 value is that specified in the table, otherwise adjust the screw (3 Fig. 3-3) (Off-Set adjuster). To increase the CO2 value, turn the adjustment screw (3) in a clockwise direction and vice versa to decrease it.

Calibration of the maximum CO2 (nominal central heating power).On completion of the adjustment of the minimum CO2 keeping the chimney sweep function active, take the heating selector switch to maximum (turn it in a clockwise direction until “99” is seen on the display). To have an exact value of CO2 in the flue gases the technician must insert the sampling probe to the bottom of the sample point, then check that the CO2 value is that specified in the table, otherwise adjust the screw (12 Fig. 3-3) (Gas flow adjuster).To increase the CO2 value, turn the adjustment screw (12) in a anticlockwise and vice versa to decrease it.At every adjustment variation on the screw 12 it is necessary to wait for the boiler to stabilise itself at the value set (about 30 sec.).

INTEC 30 COMBI INTERNALCO2 at nominal

output (central heating)

CO2 at minimum output

(central heating)NG

(G20) 9,45% ± 0,2 8,90% ± 0,2

LPG (G31) 10,60% ± 0,2 9,70% ± 0,2

3.7 CHECKS FOLLOWING CONVERSION TO ANOTHER TYPE OF GAS.

After making sure that conversion was carried out with a nozzle of suitable diameter for the type of gas used and the settings are made at the correct pressure, check that the burner flame is not too high or low and is stable (does not detach from burner);

N.B.:All boiler adjustment operations must be carried out by a qualified technician (e.g. Authorised After-Sales Technical Assistance Service).

Gas Valve 848 Key: 1 - Gas valve inlet pressure

point 2 - Gas valve outlet pressure

point 3 - Off/Set adjustment screw 12 - Outlet gas flow rate

adjuster

Page 20: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

20

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.8 PROGRAMMING THE P.C.B.The boiler is prepared for possible programming of several operation parameters. By modifying these parameters as described below, the boiler can be adapted according to specific needs.

To access the programming phase, position the DHW selector (5) on position “6”, the CH selector (6) on position “9” and press the “Reset” (3) and “Summer/Winter” buttons for about 8 seconds (2).

Once the menu has been accessed, it is possible to scroll through the three sub-menus present (s, p, t) by pressing the “Summer/Winter” (2) button for 1 second.

Use the “DHW regulator” selector (5), to select the parameter (inside the same sub-menu) and rotate the “CH regulator” selector (6) to modify the value according to the range available.

Press the “Reset” button (3) for 1 second to memorise the variation of the parameters.Memorisation is represented via “88” on the indicator (14) for 2 seconds.

Exit the programming mode by waiting for 15 minutes or by pressing the, “Reset” (3) and “Summer/Winter” (2) buttons simultaneously.

Id Parameter Parameter Description Range Default

S0 Minimum DHW output The boiler also has electronic modulation that adapts the boiler potentiality to the effective

heating demand of the house. Therefore the boiler works normally in a variable gas pressure field between minimum and maximum power depending on the system heat load, setting fan speed (in rpm, hundreds of revs are represented on the display).

N.B.:the boiler is produced and calibrated in the central heating phase at nominal output. Approximately 10 minutes are needed to reach the nominal heat output, which can be changed using the parameter (S3).

N.B.: selection of parameters in the presence of requests, allows boiler functioning with current equal to the respective value.

900 ÷ 1500 1300

S1 Maximum DHW output 3500 ÷ 6100 5100

S2 Minimum CH output S0 ÷ S3 1300

S3 Maximum CH output S2 ÷ S1 5100

S4 Power block 1500 ÷ 3500 2900

S5Central heating set point mini-

mum temperatureDefines the minimum flow temperature. 20 ÷ 50 °C 25

S6Central heating set point maxi-

mum temperatureDefines the maximum flow temperature. (S5+5) ÷ 85 °C 85

S7 External probe correction

If the reading of the external probe is not correct it is possible to correct it in order to com-pensate any environmental factors.(Over the value of +9 the display shows “CE”, which enables an external control function of the boiler for coupling of the same with a system supervisor)

-9 ÷ 9 K 0

S8 Boiler power Identifies the power of the boiler on which the P.C.B. is installed

0 = 12 kW1 = 26 kW2 = 28 kW3 = 32 kW

1

Page 21: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

21

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

Id Parameter Parameter Description Range Default

P0 DHW thermostat

Establishes the switch-off method in DHW mode.

1 Correlated: the boiler switches off on the basis of the temperature set.0 and 2 Fixed: the switch-off temperature is fixed on the maximum value independently

from the value set on the control panel.

0 - 2 2

P1 Solar delay timing

The boiler is set to switch-on immediately after a request for DHW. In the case of coupling with a solar storage tank positioned upstream from the boiler, it is possible to compensate the distance between the storage tank and the boiler in order to allow the water to reach the boiler. Set the time necessary to verify that the water is hot enough (see par. Solar panels coupling)

0 - 30 seconds 0

P2 Pump function-ing

The pump can function in two ways. 0 intermittent: In winter "mode" the pump is managed by the room thermostat or by the

remote control1 continuous: In "winter" mode the pump is always powered and so functions continu-

ously

0 - 1 0

P3 Relay 1(optional)

The boiler is set-up for functioning with the relay board (optional), which can be configured0 = Off1 = Main zone control2 =General alarm3 = CH phase active4 = External gas valve power supply5 = (Do not use on this boiler model)

0 - 5 1

P4 Relay 2(optional)

The boiler is set-up for functioning with the relay board (optional), which can be configured0 = Off1 =General alarm2 = CH phase active3 = External gas valve power supply4 = Secondary zone control (from TA on relay board contact5 = Heat pump

0 - 5 0

P5 Relay 3(optional)

The boiler is set-up for functioning with the relay board (optional), which can be configured0 = Off1 = Chiller remote activation2 =General alarm3 = CH phase active4 = External gas valve power supply5 = heat pump6 = activation of storage tank pump

0 - 6 0

Id Parameter Parameter Description Range Default

t0 Central heating ignitions timer

The boiler has electronic timing, which prevents the burner from igniting too often in central heating mode (with step of 10)

0 - 600 sec-onds 18

t1 Central heating ramp timer

In the ignition phase, the boiler performs an ignition ramp in order to arrive at the maximum power set (with step of 10)

0 - 840seconds 18

t2CH ignition de-lay from TA and

CR request

The boiler is set to switch-on immediately after a request. In the case of particular systems (e.g. area systems with motorised thermostatic valves etc.) it could be necessary to delay switch-on (with 10 step)

0 - 600 sec-onds 0

t3 Display lighting

Establishes the display lighting mode.0 Automatic: the display lights up during use and lowers after 15 seconds of inactivity.

In the case of anomaly the display flashes.1 Low: the display is always lit with low intensity2 High: the display is always lit with high intensity.

0 - 2 0

t4 Display

Establishes what the indicator displays 14 (Fig. 2-1)."Summer" mode:0: the indicator is always off1: pump active displays the flow temperature, pump off the indicator is off

"Winter" mode:0: always displays the value set on the CH selector1: pump active displays the flow temperature, pump off always displays the value set on the CH selector

0 - 1 1

Page 22: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

22

3-4b

3-4a

12

12

3

X

X

X

X

X

4

Rif. X

4

6

6

6

6

7

X

4

5

7

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.9 “CHIMNEY SWEEP” FUNCTION.When activated, this function forces the boiler to variable output for 15 minutes.In this state all adjustments are excluded and only the safety thermostat and the limit thermostat remain active. To activate the chimney sweep function, press the “Reset” button (3) until activation of the function in the absence of DHW requests.

Its activation is signalled by simultaneous flashing of the indicators (11 and 12 Fig. 2-1).

This function allows the technician to check the combustion parameters. Once the function is activated, it is possible to select whether to make the check in CH status or DHW status by opening any hot water cock and regulating the power by turning the “CH regulation” selector (6).Functioning in CH or DHW mode is visualised

by the relative symbols or .

After the checks, deactivate the function switching the boiler off and then on again.

3.10 PUMP ANTI-BLOCK FUNCTION.The boiler has a function that starts the pump at least once every 24 hours for the duration of 30 seconds in order to reduce the risk of the pump becoming blocked due to prolonged inactivity.

3.11 RADIATORS ANTI-FREEZE FUNCTION.

If the system return water is below 4°C, the boiler starts up until reaching 42°C.

3.12 P.C.B. PERIODICAL SELF-CHECK.During functioning in heating mode or with boiler in standby, the function activates every 18 hours after the last boiler check/power supply. In case of functioning in domestic hot water mode the self-check starts within 10 minutes after the end of the withdrawing in progress, for duration of approx. 10 seconds.

N.B.:during self-check, the boiler remains off.

3.13 AUTOMATIC VENT FUNCTION.In the case of new heating systems and in particular mode for floor systems, it is very important that dearation is performed correctly. The function consists in the cyclic activation of the pump (100 s ON, 20 s OFF) and the 3-way valve (120 s domestic hot water, 120 s central heating). The function is activated in two different ways:

- at every new power supply of the boiler;- by pressing buttons at the same time (2 and 4

Fig. 2-1) for 5 seconds with boiler in stand-by. N.B.: if the boiler is connected to the CARV2,

the “stand-by” function is only obtained via the remote control panel.

In the first case, the function has duration of 8 minutes and it can be interrupted by pressing the “reset” button (4). In the second case it has duration of 18 hours and it can be interrupted by simply switching the boiler on.

Activation of the function is signalled by the countdown shown on the indicator (14).

3.14 CASING REMOVAL.To facilitate boiler maintenance the casing can be completely removed as follows:• Front panel (Fig. 3-4a).1) Remove the cover caps (1) and loosen screws

(2).2) Make the control panel (3) turn over towards

you.• Casing (Fig. 3-4b).3) Unscrew the screws (4) fixing the casing front

(5) and the two sides (7).4) Slightly pull the casing front (5) in the lower

part towards you, and at the same time push upwards.

5) Unscrew the screws (6) on the sides (7).6) Remove the sides, by pulling them towards

you, in order to extract them from the two rear seats (Ref. X).

Ref. X

Page 23: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

23

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.15 VARIABLE HEAT POWER.N.B.: the pressures indicated in the table repre-sent the differences of pressures at the ends of the Venturi mixer and can be measured from the pressure point in the upper part of the sealed chamber (see pressure test 16 and 17 Fig. 1-18).

The adjustments must be performed using a digital differential manometer with a scale in tenths of mm or Pascal. The power data in the table has been obtained with intake-exhaust pipe measuring 0.5 m in length. Gas flow rates refer

to heating values below a temperature of 15°C and at a pressure of 1013 mbar. Burner pressure values refer to use of gas at 15°C.

NG (G20) Universal LPG (G31)

HEAT OUTPUT

GAS CONS.

BURNER GAS

FLOW RATE

BURNER NOZZLES PRESSURE

BURNER GAS

FLOW RATE

BURNER NOZZLES PRESSURE

(kW) (MJ/h) (m3/h) (kPa) (kg/h) (kPa)

30,0 121,6 3,22 0,41 2,36 0,4929,0 117,5 3,11 0,39 2,28 0,4628,0 113,4 3,00 0,36 2,20 0,4327,0 109,3 2,89 0,34 2,12 0,4026,0 105,2 2,79 0,32 2,05 0,3725,0 101,1 2,68 0,30 1,97 0,3524,0 97,1 2,57 0,28 1,89 0,3223,0 93,1 2,46 0,26 1,81 0,3022,0 89,0 2,36 0,24 1,73 0,2821,0 85,0 2,25 0,22 1,65 0,2520,0 81,0 2,15 0,20 1,58 0,2319,0 77,0 2,04 0,19 1,50 0,2118,0 73,0 1,93 0,17 1,42 0,1917,0 69,0 1,83 0,16 1,34 0,1716,0 65,0 1,72 0,14 1,26 0,1615,0 61,0 1,62 0,13 1,19 0,1414,0 57,0 1,51 0,11 1,11 0,1213,0 53,0 1,40 0,10 1,03 0,1112,0 49,0 1,30 0,09 0,95 0,0911,0 45,0 1,19 0,08 0,87 0,0810,0 41,0 1,09 0,06 0,80 0,079,0 36,9 0,98 0,05 0,72 0,068,0 32,9 0,87 0,04 0,64 0,057,0 28,8 0,76 0,03 0,56 0,046,0 24,8 0,66 0,03 0,48 0,035,7 23,6 0,62 0,02 0,46 0,03

Page 24: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

24

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.16 YEARLY APPLIANCE CHECK AND MAINTENANCE.

The following checks and maintenance should be performed at least once a year.- Clean the flue side of the heat exchanger.- Clean the main burner.- If deposits are detected in the combustion

chamber one must remove them and clean the heat exchanger coils using nylon or sorghum brushes; it is forbidden to use brushes made of metal or other materials that may damage the combustion chamber itself.

- Check the integrity of the insulating panels inside the combustion chamber and if damaged replace them.

- Visually check for water leaks or oxidation from/on fittings and traces of condensate residues inside the sealed chamber.

- Check contents of the condensate drain trap.- Via the condensate drain cap check that there

are no residues of material that clog condensate passage; also check that the entire condensate drain circuit is clear and efficient.

In the event of obstructions (dirt, sediment, etc.) with consequent leakage of condensate in the combustion chamber, one must replace the insulating panels.

- Check that the burner seal gaskets and the lid are intact and perfectly efficient, otherwise replace them. In any case the gaskets must be replaced at least every two years, regardless of

their state of wear.- Check that the burner is intact, that it has no

deformations or cuts and that it is properly fixed to the combustion chamber lid; otherwise it must be replaced.

- Visually check that the water safety drain valve is not clogged.

- Check that, after discharging system pressure and bringing it to zero (read on boiler pressure gauge), the expansion vessel pressure is at 1.0 bar.

- Check that the system static pressure (with system cold and after refilling the system by means of the filling valve) is between 1 and 1.2 bar.

- Visually check that the safety and control devices have not been tampered with and/or shorted, in particular:

- temperature safety thermostat;- Check the condition and integrity of the electri-

cal system and in particular: - supply voltage cables must be inside the

fairleads; - there must be no traces of blackening or

burning. - Check ignition and operation.- Check correct calibration of the burner in

domestic hot water and central heating phases.

- Check the operation of the appliance control and adjustment devices and in particular:

- system regulation probes intervention; - domestic hot water control thermostat inter-

vention.- Check sealing efficiency of the gas circuit and

the internal system.- Check the intervention of the device against

no gas ionisation flame control. The relative intervention time must be less than 10 seconds.

N.B.: in addition to yearly maintenance, one must also check the thermal system, with fre-quency and procedures that comply with the indications of the technical regulations in force.

3.17 COMBUSTION PARAMETERS.

NG (G20) Universal LPG (G31)Gas nozzle diameter mm 6,90 4,80Supply pressure kPa 1,13 2,75Flue flow rate at nominal heat output kg/h 48 49Flue flow rate at min heat output kg/h 10 10CO2 at Nom Q./Min. % 9,45 / 8,90 10,60 / 9,70CO with 0% O2 at Nom Q /Min. - 0,00153 / 0,00001 0,00160 / 0,00003NOX with 0% O2 at Nom Q /Min. mg/kWh 51 / 17 61 / 25Flue temperature at nominal output °C 40 40Flue temperature at minimum output °C 64 63

Page 25: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

25

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.18 TECHNICAL DATA.

- Flue temperature values refer to an air inlet temperature of 15°C and flow temperature of 50°C.

- The data relevant to domestic hot water performance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15°C; the values are measured directly at the boiler outlet considering that to obtain the data declared mixing with cold water is necessary.

- * Yields refer to the lower heating value.

Nominal heat input (NG / Universal LPG) MJ/h (kW) 121,6 (30,4)Minimum heat input (NG / Universal LPG) MJ/h (kW) 23,6 (5,9)Nominal heat output (useful) (NG / Universal LPG) kW 30,0Minimum heat output (useful) (NG / Universal LPG) kW 5,7* Efficiency 80/60 Nom./Min. % 98,6 / 96,7* Efficiency 50/30 Nom./Min. % 108,0 / 105,9* Efficiency 40/30 Nom./Min. % 109,0 / 106,0Heat loss at casing with burner On/Off % 0,2 / 0,48Heat loss at flue with burner On/Off % 1,2 / 0,01Central heating circuit max. operating pressure kPa 300Central heating circuit max. operating temperature °C 90Adjustable central heating temperature °C 20-85System expansion vessel total volume l 5,0Expansion vessel factory-set pressure bar 1Water content in generator l 2,3Head available with 1000 l/h flow rate kPa (m H2O) 26,4 (2,7)Weight of full boiler kg 41,1Weight of empty boiler kg 38,8Electrical connection V/Hz 230 / 50Power input A 0,66Installed electric power W 140Pump consumption W 92Fan power consumption W 27Equipment electrical system protection - IPX5DNOX class - 5Weighted NOX mg/kWh 36Weighted CO mg/kWh 27Type of appliance C13 /C33 / C43 / C53 / C63

Page 26: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

26

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.19 EXPLODED BOILER DIAGRAM.27

/05/

15

3.02

5958

SERI

AL

NU

MBE

R ST

ART

O

F SE

RIES

INTE

C 3

0 C

OM

BI I

NTE

RN

AL

196A

E

Page 27: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

27

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.20 SPARE PART LIST.N

.C

OD

ED

ESC

RIP

TIO

NSE

RIA

L N

UM

BER

STA

RT

OF

SER

IES

-3.

0259

36H

ydra

ulic

gro

up-

3.02

6048

Con

trol p

anel

- co

mpl

ete

11.

0291

65D

.8 p

ipe,

hyd

raul

ic a

ssem

bly

- ex

pans

ion

tank

21.

0309

96E

xpan

sion

ves

sel (

8 lit

res)

33.

0225

50P

ump

grou

p4

1.02

8395

NTC

pro

be5

1.02

8394

NTC

pro

be6

nfs

Hea

t exc

hang

er g

aske

t6

3.02

1695

Kit

of O

-rin

gs m

ulti-

func

tions

7nf

sO

utle

t man

ifold

clip

73.

0216

96C

lip k

it8

nfs

Pip

e cl

ip (d

.18)

83.

0216

96C

lip k

it9

1.03

0176

Sta

inle

ss s

tell

was

her (

M5,

3x10

)10

1.02

5910

Gra

phite

gas

ket f

or b

urne

r11

1.02

3442

Gas

man

ifold

cov

er12

1.02

9156

D.1

8 pi

pe, w

ater

gas

mod

ule

- hy

drau

lic g

roup

131.

0291

59C

onde

nsat

ion

mod

ule

- pum

p pi

pe

(d.1

8)14

1.03

8529

Gas

val

ve -

man

ifold

pip

e (d

.14)

151.

0339

01A

ir in

take

pip

e16

1.02

7277

Abs

olut

e pr

essu

re s

witc

h17

1.02

0211

Cor

d pa

ckin

g18

1.02

6455

Red

sili

cone

O-r

ing

(9,1

9x2,

62)

191.

0253

57G

as m

anifo

ld c

over

gas

ket

201.

0338

54E

pdm

O-R

ing

(18,

00x2

,8, 8

3sh)

211.

0153

Cro

sshe

aded

scr

ew (M

4x6)

221.

0271

78Fa

n23

1.02

6281

Bur

ner

241.

0256

90P

ress

ure

poin

t cap

251.

0286

45H

ex s

ocke

t scr

ew (M

5x45

)26

1.02

7108

Dra

in fi

tting

271.

0315

31D

.14,

2 pl

ug28

1.02

3992

Gas

ket(

24x1

6x2)

291.

0235

78C

ross

head

ed s

crew

(M5x

25)

301.

0236

76G

aske

t(d.

80)

312.

0141

85P

ipe

fixin

g fla

nge

32nf

sP

ress

ure

switc

h lo

ckin

g cl

ip32

3.02

1696

Clip

kit

331.

0352

50C

ross

head

ed s

elf-t

appi

ng s

crew

(3

x16)

341.

1176

Cro

sshe

aded

scr

ew (M

5x8)

353.

0216

96C

lip k

it36

1.02

3581

Rub

ber a

dapt

er37

1.03

4459

Cro

sshe

aded

scr

ew (M

4x20

)38

nfs

Pum

p co

uple

r fitt

ing

383.

0216

94Tw

o pu

mp

coup

ler f

ittin

gs w

ith o

-rin

g ki

t39

1.03

4173

Cap

401.

0259

11N

ut(M

6)41

3.02

6423

Fron

t cas

ing,

ass

embl

y42

1.41

39C

ross

head

ed s

elf-t

appi

ng s

crew

(3

,9x1

3)43

1.01

2468

Sta

inle

ss s

teel

ela

stic

was

her (

M5)

441.

0334

29M

5x10

hex

scr

ew45

1.22

75Fl

at p

oint

ed c

ross

head

ed s

elf-t

appi

ng

scre

w(4

,2x9

,5)

461.

0286

47In

let s

anita

ry w

ater

bod

y47

1.40

72C

lip w

ith c

lam

p sc

rew

hol

e48

1.03

8380

Bra

ss p

ress

ure

poin

t49

nfs

Per

oxid

e ep

dm O

-Rin

g (1

7,86

x2,6

2)49

3.02

1694

Two

pum

p co

uple

r fitt

ings

with

o-r

ing

kit

493.

0216

95K

it of

O-r

ings

mul

ti-fu

nctio

ns50

1.03

4405

Gas

ket(

18,5

x11,

5x2)

511.

0286

5916

-pla

te e

xcha

nger

521.

0306

02H

ex s

ocke

t scr

ew (M

5x16

)53

1.73

49C

ross

head

ed s

crew

(M4x

10)

541.

0161

87S

ilico

ne tu

be (8

x12)

551.

0017

Cro

sshe

aded

scr

ew (M

6x12

)56

1.02

4296

Flue

pro

be w

ith O

-rin

g57

1.03

0251

Igni

tion

elec

trode

gas

ket

582.

0145

24M

odul

e m

ount

bra

cket

591.

0383

79G

as n

ozzl

e (d

.6,9

0)60

1.02

1483

Sili

cone

hoo

d ga

sket

611.

0339

02Fa

n fla

nge

for p

ipe

fixin

g62

1.02

5278

Plu

g fo

r fla

nge

with

sam

ple

poin

ts63

nfs

Adh

esiv

e fo

am s

trip

(d.1

0x3)

633.

0264

23Fr

ont c

asin

g, a

ssem

bly

64nf

sA

dhes

ive

foam

stri

p (d

.15x

3)64

3.02

6423

Fron

t cas

ing,

ass

embl

y65

1.02

7009

Sili

cone

fairl

ead

(d.2

)66

nfs

Fron

t cas

ing

663.

0264

23Fr

ont c

asin

g, a

ssem

bly

671.

0379

94Fl

ange

with

sam

ple

poin

ts

682.

0136

70Lx

-Rx

wal

l, ca

sing

691.

0197

51S

ilico

ne fa

irlea

d (d

.6,5

)70

1.03

1289

Kno

b71

1.22

683.

68x1

.78

O-r

ing,

nitr

ile, 7

0 sh

721.

0366

40N

ut(M

4)73

nfs

Fron

t cas

ing,

sea

l73

3.02

6423

Fron

t cas

ing,

ass

embl

y74

1.03

0666

Gas

ket f

or fl

ange

with

sam

ple

poin

ts75

nfs

Clip

753.

0216

96C

lip k

it76

1.01

0289

Trop

ical

ized

hex

soc

ket s

crew

(M

5x16

)77

1.03

8389

PC

B78

3.02

6268

Bez

el,c

ontro

l pan

el w

ith n

amep

late

as

sem

bly

791.

0303

00C

ontro

l pan

el b

ack

cove

r80

1.02

6482

Man

omet

er81

1.03

2198

Flow

lim

iter (

14 li

tres)

821.

0303

01C

onne

ctio

n gr

oup

cove

r83

1.03

5248

Cro

sshe

aded

sel

f-tap

ping

scr

ew

(3x1

0)84

1.03

4606

Cer

amic

gla

ss (d

.20)

851.

0296

94E

nerg

y m

eter

ing

coup

ler f

ittin

g 3/

4"

M-F

861.

7908

Bla

ck c

able

cla

mp

871.

0306

29H

ydra

ulic

ass

embl

y,se

al88

1.02

8650

Ret

urn

man

ifold

891.

0286

43S

afet

y va

lve

(3 b

ar)

901.

0306

67C

onde

nsat

e dr

ain

syst

em91

1.02

5801

Stu

d M

492

1.02

4898

Gas

ket f

or m

odul

e in

spec

tion

hole

932.

0133

22Fl

ange

for m

odul

e co

ver i

nspe

ctio

n ho

le94

nfs

Epd

m O

-Rin

g (2

,57x

1,78

, 70

sh)

943.

0216

95K

it of

O-r

ings

mul

ti-fu

nctio

ns95

1.01

6246

Cro

sshe

aded

sel

f-for

min

g sc

rew

(M

4x8)

961.

0302

19C

one

poin

ted

cros

shea

ded

self-

tapp

ing

scre

w (4

,2x6

,5)

971.

0233

34G

as m

anifo

ld98

1.02

4543

Fron

t cer

amic

fibr

e pa

nel

991.

0256

89G

as m

anifo

ld g

aske

t10

01.

0285

48H

ousi

ng, o

utle

t man

ifold

101

1.03

6617

Dia

m. 1

4 co

pper

pip

e10

21.

0242

04R

ubbe

r buf

fer

103

1.60

11C

ross

head

ed fl

at p

oint

ed s

elf-t

appi

ng

scre

w(3

,5x9

,5)

104

1.03

1823

SIT

848

gas

val

ve10

53.

0203

67P

last

ic s

ipho

n10

61.

2337

Cro

sshe

aded

sel

f-tap

ping

scr

ew

(3,9

x25)

107

1.03

8565

Flow

sw

itch

108

nfs

Epd

m O

-Rin

g (1

3,94

x2,6

2, 7

0 sh

)10

83.

0216

95K

it of

O-r

ings

mul

ti-fu

nctio

ns10

91.

0338

53E

pdm

O-R

ing

(13,

94x2

,62,

83s

h)11

01.

0314

48C

onde

nsat

ion

mod

ule

111

nfs

19.8

x3.6

O-r

ing

111

3.02

1695

Kit

of O

-rin

gs m

ulti-

func

tions

112

3.02

1689

By-

pass

com

plet

e ca

rtrid

ge11

31.

8599

Was

her(

4,3x

12)

114

1.02

4680

Bur

ner g

aske

t11

51.

0223

62P

erox

ide

epdm

O-R

ing

(9,2

5x1,

78)

116

1.01

1163

Trop

ical

ized

was

her (

3,2x

7x0,

5)11

71.

0239

93G

aske

t(14

,8x8

x2)

118

nfs

Epd

m O

-Rin

g (7

,6x2

,62,

70

sh)

118

3.02

1695

Kit

of O

-rin

gs m

ulti-

func

tions

119

1.01

8602

Mot

or lo

ckin

g cl

ip12

01.

0196

54Fl

exib

le h

ose

for s

ipho

n12

11.

0380

18S

cree

n-pr

inte

d pl

ate

6 w

ay12

21.

5899

Wal

l plu

g pa

ckag

e (d

.10x

50)

123

1.02

5898

Flex

ible

hos

e (l.

200)

124

1.02

8444

Nut

for f

lexi

ble

hose

125

1.02

1452

Gas

ket f

or fl

exib

le h

ose

126

1.01

6967

Spr

ing

pipe

cla

mp

for s

ilico

ne p

ipe

(d.2

2)12

71.

0243

87"Y

" hos

e un

ion

128

1.02

4084

Cro

sshe

aded

scr

ew (M

5x14

)12

91.

0105

00S

prin

g pi

pe c

lam

p fo

r sili

cone

pip

e(d

.22)

130

1.02

5797

Klix

on th

erm

osta

t 100

°C13

12.

0144

56Fr

ame

132

1.02

8554

Pum

p bo

dy13

31.

0324

31P

ump

mot

or13

42.

0156

41V

alve

sup

porti

ng p

late

135

1.03

8378

Ven

turi

136

1.79

67C

ross

head

ed s

elf-t

appi

ng s

crew

(3

,5x1

9)

137

1.03

1572

Adj

ustm

ent-h

ole

plug

138

1.16

56N

icke

l-pla

ted

cros

shea

d se

lf-ta

ppin

g sc

rew

(3,5

x6,4

)13

91.

0285

723-

way

val

ve m

otor

140

1.02

4996

Bra

ss p

ress

ure

poin

t14

11.

0310

095-

way

term

inal

blo

ck w

ith fu

se

hous

ing

142

1.02

1762

NTC

fast

imm

ersi

on p

robe

143

2.01

4706

Spa

rk g

ener

ator

bra

cket

144

1.02

6763

Pip

e cl

ip (d

.18)

145

1.02

3554

Doo

r hin

ge m

ount

146

nfs

Fron

t cas

ing

insu

latin

g pa

nel

146

3.02

6423

Fron

t cas

ing,

ass

embl

y14

71.

0253

60S

park

gen

erat

or14

82.

0131

87C

ount

er-fr

ame

met

al s

heet

149

1.02

6000

Cas

ing

insu

latin

g pa

nel

150

1.02

7016

Sea

l, se

aled

saf

ety

valv

e15

11.

0271

10A

utom

atic

ven

t val

ve15

22.

0140

14B

rack

et fo

r exp

ansi

on v

esse

l15

31.

0312

88C

ontro

l pan

el p

ush-

butto

n15

43.

0203

80C

ompl

ete

cartr

idge

155

1.03

4442

Adh

esiv

e fo

r dis

play

156

1.02

6460

Per

oxid

e ed

pm O

-Rin

g (4

4,12

x2,6

2)15

71.

2170

Cro

sshe

aded

scr

ew (M

4x8)

158

1.02

9697

Sip

hon

tank

159

3.01

7477

Igni

tion

elec

trode

gro

up16

01.

0218

92S

ipho

n pl

ug16

11.

6984

Cro

sshe

aded

flat

poi

nted

sel

f-tap

ping

sc

rew

(2,9

x9,5

)16

21.

0309

16G

rom

met

163

1.03

8022

Scr

een-

prin

ted

plat

e16

41.

0312

93S

crew

fixi

ng te

rmin

al b

lock

165

1.68

046-

way

term

inal

blo

ck16

61.

8532

Cro

sshe

aded

sel

f-tap

ping

scr

ew

(3,9

x16)

167

1.02

5986

Sili

cone

pip

e (4

x8)

168

1.03

2007

Det

ectio

n el

ectro

de16

91.

0111

31Fa

irlea

d(d

.8)

170

1.03

4610

Ann

eale

d co

pper

was

her (

10x5

,2x1

)17

11.

4246

Lock

was

her (

M4)

172

1.02

6530

Nitr

ile O

-Rin

g (6

3x3

sh)

173

1.62

21H

ose

unio

n fo

r sili

cone

pip

e17

41.

0384

78P

lug

175

1.03

3712

2.2x

9.5

self-

tapp

ing

scre

w, c

ross

head

Page 28: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

28

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.21 BOILER REGISTRATION.

IMPORTANT INFORMATIONPlease read before Installation. Fill in and retain with the boiler for future use.

LOG BOOK - Installation, Commissioning and Service

INSTALLATION DETAILS

Immergas product - Model

Serial Number refer to data plate

Gas Type Natural Gas ☐ UNIVERSAL LPG ☐ Internal ☐ External ☐

Gas pressure setting

Central Heating. Adjusted output setting

Max kPa kW

The System pipes MUST BE FLUSHED before the connecting this boiler

New ☐ Existing ☐ System FLUSHED before installation of boiler Yes ☐

Water treatment No ☐ Yes ☐ Product Qty Used Litres

System Volume Litres Dilution rate Litres per 100 litres

Installer Details

Company Address

City State Postcode

Installer Name PIC Licence No.

Commissioning completed ☐ Date;- / /20__ by

Hand Over completed ☐ Date;- / /20__ to

Page 29: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

29

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.22 COMMISSIONING BOILER CHECK LIST.

A suggested method of commissioning the boiler, actual method can very according to the boiler make type and the installation. The boiler must always be installed, and commissioned by an qualified gas technician. The installer certifies that this Boiler has been installed to the manu-facturer’s instructions, has been filled, commis-sioned and is ready for use.

No. Description

when done

1 Read carefully the instruction manuals supplied with this boiler.

2 BEFORE INSTALLING THIS BOILER FLUSH OUT THE PIPES UNTIL CLEAN WATER IS ACHIEVED. IF REPLAC-ING AN OLD BOILER, HUNT HEATING RECOMMENDS A POWER FLUSH

3 Turn off all service to this boiler - water, gas and power. Install the boiler as shown in the instructions following and con-nect all services.

4 Turn on water to fill system, check for leaks regularly and bleed air from all points.Bleed the air from all the pumps in the system, and rotate the impeller shaft.

5 Check that all radiators valves are open, all lock shields remove the thermostatic valve heads, fully open.

6 Turn ON gas, bleed air out at the isolation valve union. Reseal and check for gas leaks.

7 Turn electricity on at the power point. At the boiler front panel set the temperature setting to the lowest setting, switch boiler to ON position.The “Power on” Indicator should light. Turn the boiler off at the front panel.

8 Turn the room thermostat to the manual ON position set the temperature to a high level so that it does not switch off during the commissioning phase. The thermostat will unusually click and shows an Indicator in the window.

9 Boiler should start fan, pump and ignite gas. If it fails first few times this may be just residual air in the gas line. A noisy water pump indicates there is air in the water pipes.

10 Boiler lights and heats the water. Check gas flame is the correct colour and for gas and water leaks as the system heats up.

11 Check that heat is circulating to all radiators through the manual or thermostatic radiator valve located on the flow pipe (unless reverse flow thermostatic valves).

12 Allow the boiler to heat up to the set temperature and switch off. Re-adjust the boiler temperature to a mid temperature point. CAUTION, if this is connected to a floor heating system. The boiler should re light and increase the water temperature to the new setting.

13 Check that all radiators are hot all the way up. If the radiator is cold at the top, then there is usually air in the radiator Bleed the radiator. Balance the system so that all radiators are hot as according to the radiator installation manual. Adjust the boiler water temperature.

14 Set the room thermostat to the correct times and temperatures according to the manufacturer’s instructions.

15 On completion of the commissioning phase, complete the information sheet at the front of this manual. Hand over the installation to the owner and demonstrate how the system works plus basic fault resolution and safety procedures. Make sure that this important document is kept in a safe accessible place.

IF IN DOUBT ASK

Handover Instructions

No. Description

when done

1 Fill in all the details on this Boiler manual.

2 Instruct the owner/users on the correct operation of this heating system, this includes how to turn the system on and off, adjust the time and temperature settings.

3 How to turn the heating system off in summer and on for winter.

4 Where all the major items are, their functions and how to check and turn them on or off. Simple fault resolution i.e. power on.

5 How to check and remove air in the radiators. Give them a bleed key.

6 The importance of this SERVICE RECORDS, keeping safe & accessible when required.

7 Recommend that the boiler should be serviced anually and that the service is recorded withing the allocated area of the boiler installation manual.

Page 30: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

30

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

3.23 SERVICE RECORDS.

Service - 1 - year 1 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Service - 2 - year 2 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Service - 3 - year 3 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Page 31: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

31

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

Service - 4 - year 4 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Service - 5 - year 5 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Service - 6 - year 6 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Page 32: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

32

INST

ALL

ERU

SER

MA

INTE

NA

NCE

TEC

HN

ICIA

N

Service - 7 - year 7 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Service - 8 - year 8 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Service - 9 - year 9 Date

Service technician Name PIC Licence No.

Service Company

Contact phone number

Work Completed

Note

Page 33: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding
Page 34: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding
Page 35: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding
Page 36: User Installation AU Instruction Manual COMBI INTERNAL · Installation of the INTEC 30 COMBI INTERNAL boiler when powered by Universal LPG must also comply with the rules regarding

This

inst

ruct

ion

book

let i

s mad

e of

eco

logi

cal p

aper

Cod

. 1.0

3847

9 - r

ev. S

T.00

1633

/000

- 06

/15