Mike BrownSenior SDDC Integration Architect, VMware, Inc.VCDX4/5/6-DCV, VCIX6-NV
@vMikeBrown
PBO1721BE
#VMworld #PBO1721BE
VMware Validated Design for Software-Defined Data Center:Technical Deep Dive
VMworld 2017 Content: Not fo
r publication or distri
bution
• This presentation may contain product features that are currently under development.
• This overview of new technology represents no commitment from VMware to deliver these features in any generally available product.
• Features are subject to change, and must not be included in contracts, purchase orders, or sales agreements of any kind.
• Technical feasibility and market demand will affect final delivery.
• Pricing and packaging for any new technologies or features discussed or presented have not been determined.
Disclaimer
2#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Building the Cloud is Often
the Bottleneck
3
VMworld 2017 Content: Not fo
r publication or distri
bution
VMware Validated DesignsPrescriptive Blueprints with Comprehensive Deployment and Operational Practices
✓Broad Use Cases
ComprehensiveDocumentation
Proven & RobustStandardized
Designs
4
VMworld 2017 Content: Not fo
r publication or distri
bution
VMware Validated Designs
5
A History Lesson
1.0
2.0
3.0
3.0.2
4.0
4.1
February 2016▪ 12mo of Engineering▪ Release to PSO
and Partners
September 2016
▪ 2mo of Engineering
▪ Dual Region with DR
▪ Two Pod Architecture
July 2016
▪ 3.5mo of Engineering
▪ Smaller scope.(i.e. Dual Region + DR)
November 2016
▪ 1.5mo of Engineering
▪ Added M-Seg Use Case
▪ Added IT Automating IT Guide
March 2017
▪ 1.5mo of Engineering.
▪ Major Product Updates
▪ Added ROBO
August 2017
▪ 4mo of Engineering• Minor Product Updates• Consolidated Pod
Option
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Design Objectives
Overall Objective SDDC capable of automated provisioning of workloads
Type of Deployment Greenfield and Brownfield
Cloud Type Private Cloud
Regions and Disaster Recovery Dual-region SDDC that Supports Disaster Recovery
▪ Guidance for an SDDC whose management components are designed to operate in the event of
planned migration or disaster recovery.
▪ Guidance for an SDDC that supports two regions for both management and tenant workloads.
▪ Operations guidance for disaster recovery and planned migration
Pods Two Pod
▪ Management Pod – Runs the management stack.
▪ Shared Edge and Compute Pod – Runs tenant workloads, and services for north-south plus east-
west routing.
One Pod
▪ Consolidated Pod – Runs the management stack, tenant workloads, and services for north-south
plus east-west routing.
Max Number of VM ▪ 10,000 Running VMs (Two Pod) / 1,500 (One Pod)
▪ 150 VM deployments/hour (Two Pod) / 60 (One Pod)
Design ObjectivesVMware Validated Design for SDDC
Design Objectives
Overall Availability 99%
= 3.65 days downtime/year
= 1.7 hours downtime/week
Planned downtime expected for upgrades, patching, on-going maintenance.
Authentication, Authorization, and
Access Control
▪ Use of Microsoft Active Directory as a central user repository
▪ Use of service accounts with minimum required authentication and Access Control List
configuration.
▪ Use of basic tenant accounts.
Certificate Signing Certificates are signed by an external certificate authority (CA) that consists of a root and intermediate
authority layers
Hardening Tenant workload traffic can be separated from the management traffic.
The design uses a distributed firewall to protect all management applications. To secure the SDDC, only
other management solutions and approved administration IP addresses can directly communicate with
individual components.
#PBO1721BE CONFIDENTIAL 6
VMworld 2017 Content: Not fo
r publication or distri
bution
Design Decisions
7
290+ in VMware Validated Design for SDDC
Reduces risk by providinga baseline of standardization.
Ensures the design meets the design objectives.
Reinforces standardization with justification and
implications.Easy to follow checklist form.
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Example Design DecisionsVMware Validated Design for SDDC
NSX Design > Routing Design > Routing Model Design Decisions (4.1)
Decision ID Design Decision Design Justification Design Implication
SDDC-VI-SDN-017 Deploy NSX Edge Services Gateways
in an ECMP configuration for
north/south routing in both
management and shared edge and
compute clusters.
The NSX ESG is the recommended
device for managing north/south
traffic. Using ECMP provides multiple
paths in and out of the SDDC. This
results in faster failover times than
deploying Edge service gateways in
HA mode.
ECMP requires 2 VLANS for uplinks
which adds an additional VLAN over
traditional HA ESG configurations.
SDDC-VI-SDN-018 Deploy a single NSX UDLR for the
management cluster to provide
east/west routing across all regions.
Using the UDLR reduces the hop
count between nodes attached to it to
1. This reduces latency and improves
performance.
UDLRs are limited to 1,000 logical
interfaces. When that limit is reached,
a new UDLR must be deployed.
SDDC-VI-SDN-019 Deploy a single NSX UDLR for the
shared edge and compute, and
compute clusters to provide east/west
routing across all regions for
workloads that require mobility across
regions.
Using the UDLR reduces the hop
count between nodes attached to it to
1. This reduces latency and improves
performance.
UDLRs are limited to 1,000 logical
interfaces. When that limit is reached
a new UDLR must be deployed.
#PBO1721BE CONFIDENTIAL 8
VMworld 2017 Content: Not fo
r publication or distri
bution
vRealize Business 7.3for Cloud
vRealize Automation 7.3vSphere 6.5 U1
vSAN 6.6.1
Site Recovery Manager 6.5.1 vRealize Log Insight 4.5and Content Packs
vRealize Operations 6.6.1and Management Packs
NSX 6.3.3
Bill of MaterialsVMware Validated Design for SDDC 4.1
For a complete list refer to the release notes.
#PBO1721BE CONFIDENTIAL 9
VMworld 2017 Content: Not fo
r publication or distri
bution
Environmental and External Systems Requirements
10
VMware Validated Design for SDDC
Active Directory
Certificate Authority
DNS and NTP
SMTP Relay
SFTP
Rack Space
Power
Cooling
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Dual-Region Deployment ReadyVMware Validated Design for SDDC
Characteristics & Restrictions
▪ Regional Distance is Rather Large
▪ A Region May Be Treated as an SDDC
▪ Multiple Regions are Not Treated as a Single SDDC
Workload Placement Closer to Customer
▪ Northern California and Southern California
▪ US East Coast and US West Coast
▪ US Region and EU Region
Common Uses
▪ Disaster Recovery: One region can be the primary site
and another region can be the recovery site.
▪ Data Privacy: Address laws & restrictions in some
countries by keeping tenant data within a region in the
same country.
San Francisco, CAPrimary Region
Los Angeles, CASecondary Region
#PBO1721BE CONFIDENTIAL 11
VMworld 2017 Content: Not fo
r publication or distri
bution
Availability ZonesVMware Validated Design for SDDC
AVAILABILIITY ZONE
AVAILABILIITY ZONE Characteristics
• “Islands” of infrastructure for physical isolation or
building-level redundancy and high-availability.
• Positioned within “metro” distance to allow
synchronous storage replication. (~50km/30mi with low single-digit latency and large bandwidth)
• Allows the SDDC equipment across the availability
zone to operate in an active/active manner as a single
virtual data center or region.
• Isolated enough from each other to stop the
propagation of failure or outage across their
boundaries.
Early Access Preview
• Guidance for vSAN Stretched Clusters
within a region.
#PBO1721BE CONFIDENTIAL 12
VMworld 2017 Content: Not fo
r publication or distri
bution
13
StandardizedElevation
NetworkTransport
Out-of-BandManagement
FunctionalRoles
PodsVMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Two Pod – Distributed Management and WorkloadVMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL 14
VMworld 2017 Content: Not fo
r publication or distri
bution
One Pod – Consolidated Management and WorkloadVMware Validated Design for SDDC
New in Version 4.1
▪ Consolidates Management, Edge, and Workload into a single pod.
▪ Requires only a minimum of 4 ESXi hosts
▪ All functional testing and validation of the design is done using vSAN.
▪ Any supported storage may be used. Adjust the operations guidance.
▪ Network Transport
▪ Supports both L2 and L3 transport services.
▪ Scalable and vendor-neutral network, use an L3 transport.
▪ Ready for Scale
▪ Expandable to a 32 ESXi host pod.
▪ SDDC solutions easily scale – deployed w/ native or NSX load balancing in place.
▪ Transitions to Two-Pod Distributed Management and Workload (Standard)
▪ Downtime Required
▪ Single Region and Single Availability Zone
▪ License Flexibility for NSX (No Universal Objects)
External
Connection
WAN/LAN
#PBO1721BE CONFIDENTIAL 15
VMworld 2017 Content: Not fo
r publication or distri
bution
High-Level Deployment Objectives
16
VMware Validated Design for SDDC
Two-Pod / Standard Architecture One-Pod / Consolidated Architecture
Minimum Hosts 8 4
Management VMs420 GB vRAM,
2TB VSAN, 6 TB NFS50% - 70% less
Recoverability Dual Region Single Region (DR to cloud)
Scale (VMs) Up to 10,000 Up to 1,500
Churn Medium (up to 150/hr) Low (up to 50/hr)
Availability 99% 95%
Modularity Foundation Cloud Operations Cloud Management Foundation Cloud Operations Cloud Management
Expansion options Additional Compute Pods (Up to 32 Hosts Each) Expand Pod to 32 Hosts or Grow to 2-Pod
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Racks
17
VMware Validated Design for SDDC
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
17 18 19 20 21 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32
CISCO NEXUS 2248PQSTAT
1 2 3 4
ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
4321
4321
4321
4321
17 18 19 20 21 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32
CISCO NEXUS 2248PQSTAT
1 2 3 4
ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
4321
4321
4321
4321
17 18 19 20 21 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32
CISCO NEXUS 2248PQSTAT
1 2 3 4
ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
4321
4321
4321
4321
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
C24 M3UCS
241 8 16
Top-of-Rack Switches for Server Connectivity
Uplinks to Spine or Corefor Inter-Pod Connectivity
ServersTwo 40GbE Uplinks
to Spine or CoreOne 48 x 1 GbE
Management SwitchTwo 48 x 10 GbE
Top-of-Rack Switches
Compatible or Certified
ConfigurationsManagement Switch for
Out-of-Band Connectivity
Two PowerFeeds
Redundant Power
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Servers
18
Management Pod – Example
1 2 3 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
SD
▪ SD/USB or SATADOM Recommended
▪ Remote Syslog
Boot
▪ On Compatibility Guide
▪ RackmountSingle or Multi-Node
▪ Blade
Form Factor
▪ 2 x Sockets min.
▪ Intel XD or AMD NX Set
▪ High-Performance in BIOS
▪ 192GB RAM min.
Compute
▪ 2 x 10 GbE to
Top-of-Rack Leaf Switches
▪ Jumbo Frames
▪ 1x 1 GbE BMC to
Out-of-Band Switch
Network
Host
▪ vSAN Hybrid or All-Flash1 x Disk Groups min
▪ Flash Device for Cache Tier1 x 200GB Flash Device min.
▪ SAS for Capacity Tier2 x 1TB SAS min.
▪ Or Any Supported Storage
Storage
SATA DOM CPU MEMORY NIC IPMIAny SupportedvSAN
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Servers
19
Shared Edge/Compute and Compute Only Pod(s) – Example
SD
▪ SD/USB or SATADOM Recommended
▪ Remote Syslog
Boot
▪ 2 x Sockets min.
▪ Intel XD or AMD NX Set
▪ High-Performance in BIOS
▪ 128GB RAM min.
Compute
Host
▪ vSAN Hybrid or All-Flashn Disk Groups
▪ SSD for Caching Tier
▪ Flash Device for
Capacity Tier
▪ Or Any Supported Storage
Storage
SATA DOM CPU MEMORY NIC IPMI
▪ On Compatibility Guide
▪ RackmountSingle or Multi-Node
▪ Blade
Form Factor
Any SupportedvSAN
▪ 2 x 10 GbE to
Top-of-Rack Leaf Switches
▪ Jumbo Frames
▪ 1x 1 GbE IPMI to
Out-of-Band Switch
Network
1 2 3 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Using vSAN? Visit vsanreadynode.vmware.com #PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Network Transport Services
▪ The VMware Validated Designs supports both L2 and L3 transport services.
▪ For a scalable and vendor-neutral data center network, use an L3 transport.
▪ When deciding to use L2 or L3, consider the following:
▪ The NSX ECMP Edge devices establish L3 routing adjacency with the first upstream L3 device to provide equal cost routing for management and workload virtual machine traffic.
▪ The investment you have today in your current physical network infrastructure.
▪ All design documentation is provided for an L3 transport. You must appropriately adjustthe design deployment and day-two operations guidance under the context of an L2 transport.
Minimal Design Requirements
▪ One 10 GbE port on each ToR for host uplinks.
▪ Host uplinks are not configured in an ether-channel (LAG/vPC)
▪ Layer 3 device that supports BGP
▪ IGMP support required by vSAN and NSX Hybrid Mode
20
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Example: L3 Leaf-and-Spine Topology
21
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Example: L3 Leaf-and-Spine Topology
22
VMware Validated Design for SDDC
Design for Workload Requirements
Compute Only Pods and Clusters May Span Racks
Management and Shared Edge/Compute Pods and ClustersMay Span Racks if L2 Network Transport is Used. Peer with Upstream L3.
Homogenous Nodes within the Pod
May Be Heterogeneous Pod to Pod
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
vSphere Clusters
23
VMware Validated Design for SDDC
ESXi ESXi ESXi ESXi
Management Distributed Switch
Universal Management Transport Zone in Hybrid Mode
Any Supported Storage
plus NFS
VTEP VTEP VTEP VTEP VTEP VTEP VTEP VTEP
ESXi ESXi ESXi ESXi
Compute Distributed Switch
Any Supported Storage
VTEP VTEP VTEP VTEP VTEP VTEP VTEP VTEP
ESXi ESXi ESXi ESXi
Compute n Distributed Switch
Any Supported Storage
VTEP VTEP VTEP VTEP VTEP VTEP VTEP VTEP
Universal Compute Transport Zone in Hybrid Mode
plus NFS
Management ClusterMinimum 4 Nodes | vSphere HA and DRS Enabled
vSAN Ready Nodes Recommended
Shared Edge and Compute ClusterBusiness Workload Requirements | Minimum 4 Nodes
vSphere HA and DRS Enabled | Edge Resource Pool and Anti-Affinity Rules
Compute Cluster nBusiness Workload Requirements | Minimum 4 Nodes
vSAN Ready Nodes Recommended
Management StackManaged by Management Stack vCenter Server
Compute StackManaged by Compute Stack vCenter Server
Management Pod Shared Edge and Compute Pod Compute Pod n
plus NFS
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Switches
24
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Storage
25
VMware Validated Design for SDDC
Primary Storage
VMware vSAN is Recommended
for Management Pod
Any Supported Storage
for Shared Edge and Compute Pod
Any Supported Storage
for Compute Only Pod(s)
Secondary Storage
NFS for Backups
NFS for Log Archives
NFS for Content Library and Templates
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
vSAN Optional for Management Pod Primary Storage
▪ Previous releases required vSAN as primary storage in the management pod. This requirement has been relaxed inthe 4.1 release.
▪ All functional testing and validation of the design is done using vSAN.
▪ Although the VMware Validated Designs highly recommend the use of vSAN, in particular for the management pods, any supported storage solution may be used.
▪ If a storage solution other than vSAN is selected:
▪ You must appropriately adjust the design deployment and day-two operations guidance under the context of vSAN.
▪ The storage design must match or exceed the capacity and performance capabilities of the vSAN configuration in the design.
VMware Validated Design for SDDC
0%
50%
100%
25%
75%
0%
50%
100%
25%
75%
vSAN
Datastore
Non-vSAN
Datastore
#PBO1721BE CONFIDENTIAL 26
VMworld 2017 Content: Not fo
r publication or distri
bution
NFS Secondary Storage
27
VMware Validated Design for SDDC
Volume 1 Volume 2
NFS Storage Array
Region A
Export for Backups
Export for
Content Library
and Templates
Export for
Log Archives
Volume 1 Volume 2
NFS Storage Array
Region B
Export for Backups
Export for
Content Library
and Templates
Export for
Log Archives
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
vCenter Server and Platform Services
28
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Two-Layer Certificate Authority + Certificate Replacement
CertGenVVD tool saves you time when creating signed certificates. See VMware Knowledge Base article 2146215.
Certificate Mode
▪ VMCA Hybrid Mode
▪ All user-facing certificates are signed by a certificate authority (CA).
▪ All virtual infrastructure management components use TLS/SSL certificates that are signed by the VMware Certificate Authority (VMCA).
▪ Supports a Two-Layer CA environment.
Certificate Replacement
▪ If the CA-signed certificates expire after you deploy the SDDC, you must replace them individually on each affected component.
▪ Provides guidance for replacing all CA-signed certificates that are expiring. *
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL 29
VMworld 2017 Content: Not fo
r publication or distri
bution
NSX
30
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Logical Networking
31
VMware Validated Design for SDDC
Universal Distributed Logical Router
UDLRCTRL
ECMPESG
ECMPESG
ECMPESG
ECMPESG
LEAF LEAF LEAF LEAF
BGP BGP BGP BGP
Universal Transit Logical Switch
VC PSC NSXM NSXC VC PSC NSXM
SPINESPINERegion A Region B
Virtual Networks
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
32
VMworld 2017 Content: Not fo
r publication or distri
bution
Cloud Operations
33
VMware Validated Design for SDDC // vRealize Operations
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Cloud Operations
34
VMware Validated Design for SDDC // vRealize Log Insight
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Management Packs and Content PacksVMware Validated Design for SDDC
Now Included by default with product deployment.
▪ Management Pack for vCenter Server
▪ Management Pack for vRealize Log Insight
▪ Management Pack for vSAN (New in v6.6)
▪ Management Pack for vRealize Automation (New in v6.6)
▪ Management Pack for vRealize Business for Cloud (New in v6.6)
Installed post-deployment.
▪ Management Pack for NSX for vSphere
▪ Management Pack for Storage Devices
Now Included by default with product deployment.
▪ General
▪ Content Pack for vSphere
▪ Content Pack for vSAN (New in v4.5)
▪ Content Pack for vRealize Operations
Installed post-deployment.
▪ Content Pack for NSX for vSphere
▪ Content Pack for vRealize Automation 7
▪ Content Pack for vRealize Orchestrator 7.0.1+
▪ Content Pack for Linux (Added to the Architecture)
▪ Content Pack for Microsoft SQL Server
vRealize Operations 6.6.1Management Packs
vRealize Log Insight 4.5Content Packs
VMworld 2017 Content: Not fo
r publication or distri
bution
Region A
vRealize Automation vRealize Business
BUC
BUS
vRO
vRA IWS IMS DEM IAS SQL
vRA IWS IMS DEM IAS
Region B
IAS
Cloud Management Platform Components
36
VMware Validated Design for SDDC
BUS vRealize Business Appliance
BUC vRealize Business Data Collector
SQL Microsoft SQL Server Database
VRA vRealize Automation Appliance
IWS vRealize Automation IaaS Web Server
IMS vRealize Automation IaaS Manager Service
IAS vRealize Automation IaaS vSphere Proxy Agent
DEM vRealize Automation Distributed Execution Manager
BUC
IAS
vRealize Automation
and Business
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Distributed Deployment with NSX
37
VMware Validated Design for SDDCVMware Validated Design for SDDC // Cloud Operations
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
Disaster Recovery of SDDC Solutions
38
VMware Validated Design for SDDC
Region A Non-Replicated
vRealize Log Insight
Region A Infrastructure Management
vSphere
NSX
Site Recovery Manager
vSphere Data Protection or VADP-Based Solution
Region A Replicated
vRealize Operations
vRealize Automation
vRealize Business
SRM(using vSphere Replication)
Region B Infrastructure Management
vSphere
NSX
Site Recovery Manager
vSphere Data Protection or VADP-Based Solution
Region B Non-Replicated
vRealize Log Insight
Region B Replicated
vRealize Operations
vRealize Automation
vRealize Business
SRM (using vSphere Replication)
#PBO1721BE CONFIDENTIAL
VMworld 2017 Content: Not fo
r publication or distri
bution
DocumentationVMware Validated Design for SDDC
≠
Release Notes
Architecture Details
Architecture Diagrams
Planning and Preparation Guides
Step-by-Step Deployment Guides
Operations Guides
▪ Monitoring and Alerting
▪ Business Continuity
▪ Disaster Recovery
▪ Plus more Operations Add-ons
Download the Docs Todayvmware.com/go/vvd-docs
VMware Validated Design 4.1 Documentation Center
#PBO1721BE CONFIDENTIAL 39
VMworld 2017 Content: Not fo
r publication or distri
bution
Sizing Tool on VMware Code
Provide qualified partners a sizing tool for deployments adhering to the VMware Validated Design for SDDC.
Online web based tool which integrates with VMware Compatibility Guide to pull certified vSAN ReadyNodedetails.
vmware.com/go/vvd-sizing
VMware Validated Design for SDDC
#PBO1721BE CONFIDENTIAL 40
VMworld 2017 Content: Not fo
r publication or distri
bution
41
Download the Poster Todayvmware.com/go/vvd-sddc-poster
VMworld 2017 Content: Not fo
r publication or distri
bution
VMworld 2017 Content: Not fo
r publication or distri
bution
VMworld 2017 Content: Not fo
r publication or distri
bution