Chapter Next KFG, KFGS Pump Unit Operating Instructions

Vogel - Operating Instructions

Embed Size (px)

Citation preview

Page 1: Vogel - Operating Instructions

ChapterNext

KFG, KFGS Pump UnitOperating Instructions

Page 2: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

This Manual has been compiled in conformitywith current standards and regulations oftechnical documentations, such as VDI 4500and EN 292.

© Copyright Willy Vogel AGAlterations due to technical improvements reserved.

Made byMDC Industriewerbung & Grafik Design GmbH

Page 3: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

Pump Units of the SeriesKFG, KFGS

Keep for future use!

CE Conformity markingThe pumps of the KFG and KFGS series aremarked with the EC conformity sign.

Application of Technical Standardsand Guidelines72/245/EWG (Vehicles)89/336/EWG (Electromagnetic Compatibility)98/37/EG (Machines)

Service Center Berlin (++49) 30-7 20 02-180 (++49) 30-7 20 02-212

Page 1

Page 4: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

Page 2

Berlin, November 2000

Manufacturer’s Certificate

Manufacturer’s Certificate in themeaning of the EC Machine Directives98/37/EC, Annex II B

We herewith certify that the equipmentand pump sets with vessels of the Series

FLM, FLMF, M, ME, MF, MFE, MK, MKE, KFG,KFGS, KFK, OLA, P, PF, PFH, PFP, PFM, PHU,PMA, PPU, PW, PEW, PFPW, ZAN, ZR, ZM,121, 122, 123, 124, 125, 126, 127, 128, 129, 130,132, 134, 133, 142, 143, 149

are designated to be fitted in a machine / to beassembled with other machines to form onemachine.Their commissioning is prohibited until it has beenverified that the machine in which this part shallbe fitted or which shall be assembled with this partconforms to the regulations of the EC Directives(98/37/EC).

The standards here applied and adapted are,in particular, pr EN 809, EN 292 T1 andEN 292 T2.

WILLY VOGELAktiengesellschaft

Heinz Gaub Uwe Schumann(Member of the Board) (Sales Management for

Industrial Lubrication)

Page 5: Vogel - Operating Instructions

Next

Operating Instructions KFG, KFGS

Page 3

This declaration has been made in reponsibilityfor the manufacturer/importer

WILLY VOGEL AktiengesellschaftMotzener Strasse 35 / 37, 12277 BerlinPostfach 480149, 12251 Berlin

by the Members of the Board

Heinz Gaub Manfred Neubert

Berlin, 7th November 2000

Certificate of EC Conformation

It is hereby certified that the following productnamed

Piston pump with vesselwith the order codes:

KFGS 1-5, KFGS 3-5, KFGS 5-5

conforms to the essential protection requirementsas laid down in the following directives for theharmonization of legal regulations of the MemberStates.

Electromagnetic Compatibility89 / 336 / EWG,amended by92 / 31/ EWG, 93/68/EWG

Conformity has been verified by the application ofthe following (harmonized) European standards:

EN 50081-1EN 50082-2

Motor vehicle 72 / 245 / EWGamended by89 / 491 / EWG, 95 /54 / EWG

• This Certificate testifies the conformation withthe said Directives, but it does not include anywarranty of qualities.

• The Safety Instructions referred to in the respective paragraphs of the annexed documentation have to be heeded.

• Commissioning of the certified products is prohibited until it has been ensured that the machine, vehicle or the like, where the producthas been installed, conforms to the regulationsand requirements of the applicable directives.

• Operation of the products with non-standard operating voltage and non-observance of installation instructions may affect the qualitiesof electromagnetic compatibility and electricalsafety.

Chapter

Page 6: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

6. Programming 286.1 Start of programming mode 286.2 Alteration of times for lubrication interval 286.3 Alteration of system monitoring 296.4 Alteration of operating modes 296.5 Alteration of code 306.6 Programming ranges 306.7 Display ranges 30

7. Operating modes 317.1 Timer operation 317.2 Counter operation 31

Operation in machinesOperation in vehicles

7.3 Without system monitoring 327.4 With system monitoring 327.5 Monitoring of filling level 327.6 Monitoring by cycle switch 33

8. Operating trouble 348.1 Display of faults 348.2 Deletion of fault messages 348.3 Storage of fault times 358.4 Maintenance and repair 358.5 Block operation 368.6 Pump trouble 37

Service in Germany 39Service worldwide 40

Contents

Page 4

1. Safety Instructions 6

2. Installation 82.1 Fitting dimensions 92.2 Pump elements 102.3 Adjustable volumetric deliveries 112.4 Excess pressure valve 122.5 Filling up lubricant 132.6 Checking of filling level 142.7 Venting of the system 14

3. Electrical connection 153.1 General conditions of connection 153.2 KFG Series 163.3 External controlling devices 163.4 KFGS Series 173.5 Connecting options 173.6 Timer operation 183.7 Counter operation 19

4. Display and operating unit 204.1 The three-digit led display 214.2 Display by light-emitting diodes 234.3 Operation by push-button switches 24

5. Display mode 26

Page 7: Vogel - Operating Instructions

ChapterContents

Operating Instructions KFG, KFGS

Page 5

filling-uppage 13

electrical connectionpage 15

pump elementspage 10

lubricant vesselpage 9

installationpage 8

filling-uppage 13

control, in generalpage 20electrical connection

page 15

pump elementpage 10

excess pressure valvepage 12

programmingpage 28

KFG KFGS

Page 8: Vogel - Operating Instructions

ChapterNext

1

Operating Instructions KFG, KFGS

Page 6

General

The components have been manufactured incompliance with the generally established rules ofengineering as well as with regulations of laboursafety and accident prevention. Their use may stillprovoke dangers, entailing physical harm to theuser or third persons or damage to assets.Therefore, the components may be used only whenthey are in a proper technical state and with dueadherence to the operating instructions. Any faultswhich, in particular, may affect safety have to beeliminated immediately.

Use in compliance with the intended purpose

The pump sets of the VOGEL KFG and KFGSseries are applied for feeding centralized lubricationsystems in vehicles, equipment and machines.They deliver grease of up to NLGI Class 2.Any use beyond the above purpose shall bedeemed as not being compliant with the intendedpurpose.

Authorized staff

Only qualified staff shall be allowed to install,operate, maintain, and repair the componentsdescribed in this Manual. Qualified staff shall meanpersons who have been trained, commissioned,and instructed by the user of the equipment. Suchpersons, on account of their training, experience

and instructions received, are familiar with therelevant standards, rules, accident preventionregulations and operating conditions. They areauthorized to carry out the works required in eachcase and, when doing so, are aware of possibledangers and are able to prevent them. The definitionof qualified staff and the prohibition of employingnon-qualified staff is laid down in DIN VDE 0105or IEC 364.

Exclusion of liability

Willy Vogel AG will not assume liability for damage:

• occurred due to lack of lubricant

• caused by soiled or improper lubricant

• caused due to the installation of non-original Vogel components or Vogel spare parts

• caused due to any use non-compliant with theintended purpose

• due to faulty installation and filling

• due to wrong electrical connection

• due to wrong programming

• due to improper reaction to failures

1. Safety instructions

Installation

When carrying out any installation works on vehiclesand machines, regional accident preventionregulations as well as relevant operating andmaintenance specifications have to be observed.

Danger by electric current

Only properly trained specialist staff shall be allowedto carry out the electrical connection of the devices,taking into account local conditions for connectionand regulations (e.g. DIN, VDE)! Considerabledamage to material and persons may be provokeddue to the improper connection of devices!

Danger by pressurized systems

Systems may be pressurized so that they have tobe depressurized prior to commencing works for extension, modification, or repair of the systems.

Page 9: Vogel - Operating Instructions

Page 7

Transport and storage

KFG and KFGS pump sets will be packaged ascustomary in trade, complying with the regulationsof the receiving country and VDA 6-01 as well asDIN ISO 9001.There are no restrictions as to land, air, or maritimetransport.Store in a dry place at a storage temperature from-40 °C to +70 °C.Packages must be handled with care!

Text portions in this Manual marked withthis symbol indicate particular dangersor important operations.

Approved lubricants

Greases of up to NLGI Class 2, DIN 51818, anda max. flow pressure of 700 mbar.The list of approved lubricants is permanentlybeing updated and can be accessed via thefollowing addresses:

„Schmierstoffe für Progressivanlagen“ on:www.vogelag.comor via the Service Center, Berlinfax: ++49 -030 -7 20 02 -138

Note the lists of approved lubricants issued by machine or vehicle manu-facturers!

Danger to the environment caused by lubricants

The lubricants as recommended by manufacturerscorrespond in their composition to current safetyregulations. Nevertheless, oils and greases arebasically substances endangering the ground waterso that their storage, processing, and transportrequires to take special safety measures.

ChapterContents

1

Operating Instructions KFG, KFGS

Page 10: Vogel - Operating Instructions

Fig. 1 Bores for installation

ChapterContents

2

Operating Instructions KFG, KFGS

When carrying out boring operations, mind existing supply lines and other equipment as well as any further sources

of danger, such as exhaust pipes or movingparts.Observe safety distances as well as regionalregulations for installation and accidentprevention.

Page 8

Installation

Installation of the pump sets KFG and KFGS shallbe done on a vehicle or machine by means of3 M8 bolts. The mounting should be in a placewhich is protected from outside influence as far aspossible. Any bores required for installation shallbe made according to the following diagram.A boring jig can be ordered underarticle no. 951-130-115.

2. Installation

200 ± 0,4

75±

0,4

General

The pump sets of the KFG and KFGS series formpart of centralized lubrication systems in vehicles,machines, and equipment, delivering greases ofup to NLGI Class 2.

The pump sets differ in the size of their lubricantvessels, in their way of filling up lubricant, as wellas in their control and monitoring of functions.

The installation of function-specific pump elementsallows up to three independent lubricant circuitsto be operated by only one pump set. (see Chapters 2.2 and 2.3).

Page 11: Vogel - Operating Instructions

ChapterContents

2

Operating Instructions KFG, KFGS

Page 9

C

2.1 Fitting dimensions

B

A

D

A (mm) B (mm) C (mm) D (mm) weight (kg) with filled lubricantvessel

KFG1-5 210 230 ø 180 266 7KFG3-5 210 412 ø 226 266 11KFG5-5 210 585 ø 205 266 15

KFGS1-5 210 282 ø 180 266 7KFGS3-5 210 464 ø 226 266 11KFGS5-5 210 637 ø 205 266 15

Page 12: Vogel - Operating Instructions

ChapterContents

2

Operating Instructions KFG, KFGS

The pump elements are marked with grooves onthe outer sides of the wrench contact surface.

Available pump elements

The values indicated apply to a tempe-rature of 20 °C, a counterpressure of 50bar, and greases of NLGI-Class 2.

Example for ordering:KFG1-5 24 V DC assembled with2 pcs. KFG1.U4 left-hand and right-hand1 pc. KFG1.U1 centre

Page 10

2.2 Pump elements

The KFG and KFGS pump sets are provided withthree lubricant outlets, to each of which a separatepump element can be connected for an indepen-dent progressively-acting distributor circuit. Whereoutlets are not required, a screw plug acc. to DIN910-M20 x 1.5 - 5.8 with gasket ring acc. to DIN7603-A20 x 24-Al will be inserted.The pump elements shall be ordered in conformitywith the necessary volumetric delivery.

Fig. 2 Pump element

All pump elements are provided with an M14x1.5internal thread for connecting an excess pressurevalve with a pipe connector for steel pipes of6 mm ø or 10 mm ø .

Pump element with constant volumetric deliverywithout excess pressure valve

M20 x1,5

M14

x1,

5

Fig. 3 KFG1.U2

article volumetric deli- number ofcode very in cm3/min grooves

KFG1.U1 2.5 1KFG1.U2 1.8 2KFG1.U3 1.3 3KFG1.U4 0.8 4

KFG1.U40 0.8 -2.4(adjustable) see Chapter 2.3

Page 13: Vogel - Operating Instructions

ChapterContents

2

Operating Instructions KFG, KFGS

Page 11

Remove screw plug with hexagon socket wrench,width across flats 6

Set adjusting screw with hexagon socket wrench,width across flats 8. Turning in clockwise directionwill decrease, and turning in anticlockwise directionwill increase volumetric delivery

Max. travel of adjusting screw:3 turns =6 indexed positions.1 turn of adjusting screw =1mm =2 indexed positions

After the adjusting process, screw in and tightenthe screw plug.

turns

1 2 3 4 5 6indexed positions

2.42.0

1.0 0.8

Chart for volume controlVolumetric delivery in cm3/min

2.3 Adjustable volumetric deliveries

1 screw plug2 pipe connector3 pump element KFG1.U3

Fig. 5 Connection of pump elements

adjusting screw, internal,width across flats 8

M20

x1,

5

cutting ringconnectorfor pipeof ø 6

screw plug, internal width across flats 6

Fig. 4 KFG1.40 with excess pressure valve

excess pressure valve,nominal pressure 300 bar

SW

01 2 3

2 1 3

Page 14: Vogel - Operating Instructions

ChapterContents

2

Operating Instructions KFG, KFGS

Page 12

An excess pressure valve protects the entirelubrication system against excessive systempressures. It is mounted directly on the pumpelement.The opening pressure adjusted for this valve is300 bar.If any blocking in a progressively-acting distributoror lubrication point causes the operating pressureincrease over 300 bar, the valve will open withgrease clearly emerging.This serves for visualized system control.

article code pipe openingpressure in bar

161-210 -012 ø 6 mm 300 bar ± 20 bar161-210 -016 ø10 mm

A connector for 10 mm ø pipe

P

R

AP

R

M14

x1,

5

P A

A connector for 6 mm ø pipeP connecting thread for pump elementR grease outlet in case of fault

Fig. 6 Excess pressure valves

2.4 Excess pressure valve

A

PM

14x

1,5

RR

A

Page 15: Vogel - Operating Instructions

ChapterContents

2

Operating Instructions KFG, KFGS

Page 13

Filler coupling (fluid grease)

For single parts, see Vogel Catalogue 1-9430,page 51. Remove grease nipple and replace it withfiller 995 -000 -705. Mount the coupling sleeve995-001-500 on the filling pump.

Cone-shaped grease nipple

Filling with lubricant shall be done through thecone-shaped grease nipple, DIN 71412 -AM10x1,by means of a common grease gun.

1 cone-shaped grease nipple2 connection for installation

Fig. 7 Cone-shaped grease nipple

The positioning of the cone-shaped grease nipplemay be changed by screwing it in at position 2.Alternatively, connection 2 may be used for fittinga lubricant return system, if any.

Filling cylinder

For single parts, see Vogel Catalogue 1-9430,page 15. Remove screw plug M20 x 1.5 and replaceit with filler connector 169-000 -170. For fillingoperation, remove protective caps 1 at connectorand filling cylinder.

Remove protective cap 1 for filling operation

Fig. 8 Filling Fig. 9 Filling

1

filling cylinder169-000-171

filler connector169-000-170

M20 x 1,5coupling sleeve995 -001-500

995 -000 -7051

12

2.5 Filling up lubricant

Page 16: Vogel - Operating Instructions

ChapterContents

2

Operating Instructions KFG, KFGS

Hinged lid

As special design in the KFG3-5, KFG5,KFGS3-5, KFGS5 -5 series, lubricant can be filledup through a hinged lid.

KFG3-5 KFG5-5KFGS3-5 KFGS5-5

Fig. 10 Hinged lid

Fill in only clean lubricant with the helpof a suitable tool.

Soiled lubricant leads to serious systemtrouble!

Visual checking

The transparent lubricant vessel allows visualchecking of the filling level. Such checking needsregularly to be carried out for safety reasons.

If the vessel was emptied below the „min“ mark, the entire system has to be vented.

Automatic checking

The pumps of the KFGS series are provided forautomatic checking of the filling level. If the levelfalls below the „min“ mark, the lubrication processis stopped with the error message „FLL“ shownon the display.

Take off the main lines at the pump set. Keeppumping until bubble-free lubricant emerges at thescrew fitting. Fit the main lines.

Take off the main line at the main distributor. Keeppumping until there is no air in the line. Fit the mainline.

Take off the branch lines at the main distributor.Keep pumping until bubble-free lubricant emergesfrom all connectors of the main distributor. Fit thebranch lines.

Then vent the branch lines, branch distributors,lubricant lines and lubrication points and check forproper functioning.

Page 14

2.6 Checking of filling level 2.7 Venting of the system

Page 17: Vogel - Operating Instructions

ChapterContents

3

Operating Instructions KFG, KFGS

Page 15

3. Electrical connection

Compare operating voltage with the data on the rating plate.

nominal power power pump max.voltage absorption absorption starting pre-

(load- (max.) current connecteddependent) (abt. 20 ms) fuse

KFG / KFGS 24 V DC 1.25 A 2) < 2.5 A 4.5 A 3 A 3) 4)

application in vehicles 12 V DC 2.4 A 2) < 5 A 9 A 5 A 3) 4)

KFG 24 V DC 1) 1.25 A 2) < 2,5 A 4.5 A 4 A 4)

application in the 12 V DC 1) 2.4 A 2) < 5 A 9 A 6 A 4)

industrial sector

1) protective measures to be applied for the operation according to the intended purpose„Function-specific extra-low voltage with safe circuit-breaking“„Protective Extra Low Voltage“ (PELV)

Standards: EN 60204 Part 1:, 1992 /IEC 204-1: 1992, amendedDIN EDV 0100, Part 410 / IEC 364-4-41: 1992

2) typical value for ambient temperature = 25 °C and operating pressure =150 bar3) circuitbreaker acc. to DIN 72581 T.34) conductor: cross-section 1.5 mm2, length ≤ 12 m

3.1 General conditions of connection

Page 18: Vogel - Operating Instructions

ChapterContents

3

Operating Instructions KFG, KFGS

Vehicle

15 + Supply voltage potential(ignition switch ON)

31 - Supply voltage potential(0 V, GND)

F fuse acc. to DIN 72581 T3

Industrial sector

L+ + Supply voltage potential(machine main switch ON)

M - Supply voltage potential(0 V, GND)

The electrical connection is made via a plugconnector acc. to DIN 43650, type A

X1 plug connector

3.3 External controlling devices

For controlling the lubrication and pause periodsas well as for monitoring the lubrication process,the following external controlling devices areprovided:

Vehicle Industry

IG502-E IGZ 51-2IGZ 51-2-S2IGZ 51-2-S7IGZ 51-2-S8

It is a basic requirement to observe theUser's Guide and/or the description of functions of the respective controlling device.

Page 16

3.2 KFG series

2

3 1

1

KFG...

F

2 3X1

1)

2) 2)

+M-

31 15 (vehicle)M L+ (industry)

1) external controlling devicerelay contact „pump ON“

2) X1-PIN without internal connection

Fig. 11 Plug and PIN assignment

Page 19: Vogel - Operating Instructions

ChapterContents

3

Operating Instructions KFG, KFGS

Page 17

Trailer operation = counter operation withoutsystem monitoring

programming: cPA, tCO, COP = OFFsee Chapter 6

Cable set for trailer operation only!

article no. length of corru- lengthgated sleeving of cores

997-000 -760 12 m 12.2 m

31 54 (from stop light switch)(Note start-up current of pump!)

31 - Supply voltage potential (0V, GND)54 stop light switch signal

3.4 KFGS series

With integrated control

The electrical connection of the KFGS series ismade at the bottom side of the set by means ofa seven-pin plug.

Connection forcable set

The cable set is not partof the supplies!

article no. length of corru- lengthgated sleeving of cores

997-000-630 12 m 12.2 m997-000-650 16 m 16.2 m

2

4

5

31

6 7

3.5 Connecting options

Fig. 12 seven -pin round plug

Colour marking

X1-Pin Colour symbol Colour of core

1 BN brown2 RD-BK red/ black3 BU blue4 PK pink5 BK black6 BK black7 VT-GN violet /green

1

BN

KFGS...

F

2 3 4 5 6 7X1

RD

-BK

BU

Page 20: Vogel - Operating Instructions

ChapterContents

3

Operating Instructions KFG, KFGS

Page 18

1

BN

KFGS...

F

2 3 4 5 6 7X1

RD

-BK

BU PK

VT-

GN

DK SL2

2,4 W

SL1

2,4 W

BK

BK

ZS+

1

BN

KFGS...

F

2 3 4 5 6 7X1

RD

-BK

BU PK

VT-

GN

DK SL2

2,4 W

SL1

2,4 W

Timer operation with system monitoring

Programmierung: tPA, tCO, COP = CS

Timer operation without system monitoring

programming: tPA, tCO, COP = OFF

3.6 Timer operation

31 15 (vehicle)M L+ (industry)

31 15 (vehicle)M L+ (industry)

15 + Supply voltage potential (ignition switch ON) vehicle31 - Supply voltage potential (0 V, GND)

L+ + Supply voltage potential (machine main switch ON) industryM - Supply voltage potential (0 V, GND)

DK push-button 1. intermediate lubrication 2. delete fault message generalSL1 signal lamp „pump ON“SL2 signal lamp „fault“ZS cycle switch colours of coresX1 plug connection table on page 17

Page 21: Vogel - Operating Instructions

ChapterContents

3

Operating Instructions KFG, KFGS

Page 19

3.7 Counter operation

Counter operation with system monitoring

programming: cPA, tCO, COP=CS

Counter operation without system monitoring

programming: cPA, tCO, COP = OFF

31 15 (vehicle)M L+ (industry)

31 15 (vehicle)M L+ (industry)

15 + Supply voltage potential (ignition switch ON) vehicle31 - Supply voltage potential (0 V, GND)

L+ + Supply voltage potential (machine main switch ON) industryM - Supply voltage potential (0 V, GND)

MK machine contact generalSL1 signal lamp „pump ON“SL2 signal lamp „fault“ZS cycle switch colours of coresX1 plug connection table on page 17

1

BN

KFGS...

F

2 3 4 5 6 7X1

RD

-BK

BU PK

VT-

GN

MK SL2

2,4 W

SL1

2,4 W

1

BN

KFGS...

F

2 3 4 5 6 7X1

RD

-BK

BU PK

VT-

GN

MK SL2

2,4 W

SL1

2,4 W

BK

BK

ZS+

Note:In counter operation with the machinecontact closed, 1 pulse will be countedeach time the operating voltage isswitched on.

Page 22: Vogel - Operating Instructions

ChapterContents

4

Operating Instructions KFG, KFGS

Page 20

4. Display and operating unit

Fig. 13 Display and operating unit

KFGS series only

A transparent plastic screen protects the displayand operating unit against splash water andmechanical damage.For the purpose of programming, remove thescreen with a screwdriver and fix it again afterward.

CS

LED display

• seven-segment display: values andoperating conditions

• progression of pause

• pump operation

• monitoring of system functions by means of anexternal cycle switchCS = cycle switch

• Without function in progressively-actingsystems

• fault message

Push-button switches

• switching the display on• displaying values and parameters• setting values and parameters

• changing between programming and display modes• confirming values

• releasing intermediate lubrication• deleting a fault message

PAUSEh/lmp

CONTACTmin/lmp

PS

FAULT

Page 23: Vogel - Operating Instructions

ChapterNext

4

Operating Instructions KFG, KFGS

4.1 The three-digit LED display

In normal operation the display is switched off.It can be activated by shortly pressing one of thetwo push-buttons . The display showscurrent values and preset parameters.Furthermore, the display serves for user promptingwhen operating parameters are programmed.

Page 21

display function

t = timer The control device is working as • Part of lubrication cyclePA = Pause timing pulse generator (TIMER) • Input and display values

and is in the PAUSE mode. in hours

c = COUNTER The control device is working as • Part of lubrication cyclePA = PAUSE pulse counter (COUNTER) and is • The device is counting the

in the PAUSE mode. pulses of the external pulsegenerator and is comparing them with the preset values

t = TIMER The control device is working as • CONTACT = timeCO = CONTACT timing pulse generator (TIMER) while the pump delivers

and is in the pump operating • Input and display valuesperiod (CONTACT) in minutes

c = COUNTER The control device is working as • CONTACT = timeCO = CONTACT pulse counter and is in the pump while the pump delivers

operating period (CONTACT) • input and display values in pulses

C = cycle Display of menu startO = OFF „monitoring settings“P = Pressure

meaning

Page 24: Vogel - Operating Instructions

ChapterContents

4

Operating Instructions KFG, KFGS

Page 22

display meaning

Monitoring PS and CS monitoring function • No system monitoringOFF is switched off

Cycle Switch Monitoring of cycle • During the CONTACT pumpswitch is activated operating period, the cycle

switch is monitored for pulse generation.

Fault: Low Level Minimum filling level • The control device is in the in storage vessel is reached FAULT mode.

• The process of functions has been stopped.

Fault: Cycle No signal of cycle switch during • The control device is in theSwitch pump operating period FAULT mode.

• The process of functions hasbeen stopped.

Operation The values displayed in the following are the operating hoursHour Meter of the control device.

Fault The values displayed in the following are the fault hours which isHour Meter the time while the vehicle or machine has been operated in

the FAULT mode.

Block Operation Signal from cycle switch not available. As opposed to normal operation,the control device is still in the monitoring process. If the fault continuesover 3 pump periods, a fault message will be displayed.

Page 25: Vogel - Operating Instructions

ChapterContents

4

Operating Instructions KFG, KFGS

4.2 Displayby light-emitting diodes

CS

PS

CONTACTmin/lmp

FAULT

PAUSEh/lmp

LED LED is on = display mode LED is flashing = programming mode

The operating voltage is applied at The value for PAUSE can be altered.the pump set and the controldevice. The system is in thePAUSE mode.

The operating voltage is applied at The value for CONTACT can be altered.the pump set and the control device.The system is in the CONTACTmode (pump motor is ON).

For system monitoring, a cycle This mode of monitoring can be switchedswitch is used. Monitoring takes off in the programming mode.place at the progressively-acting COP = CS monitoring is active

distributor while the pump is in COP = OFFoperation. (CONTACT) monitoring is switched off.

Pressure switch monitoring is not Monitoring by pressure switch mustpossible in progressively-acting not be activated in progressively-distributor systems. acting systems.LED must not be ON. COP = CS or COP = OFF

The operating voltage is applied at the pump set and the control device. The controldevice is in the FAULT mode. The fault can be called via the LED display and be visualized as error code after pressing the push button.The process of functions is stopped.

Page 23

Page 26: Vogel - Operating Instructions

ChapterNext

4

Operating Instructions KFG, KFGS

Page 24

4.3 Operationby push-button switches

• Actuation during PAUSE releases intermediate lubrication.

• Fault messages are acknowledged and deleted

• Switching on the display in the display mode

• Calling the next parameter in the programming mode

• Increases the displayed value by 1

• Switching on the display in the display mode

• Calling the previous parameter in the programming mode.

• Decreases the displayed value by 1

• Changes between programming mode and display mode

• Confirms entered values

push-buttonswitch

operating options

Page 27: Vogel - Operating Instructions

ChapterContents

4

Operating Instructions KFG, KFGS

Page 25

Page 28: Vogel - Operating Instructions

ChapterNext

5

Operating Instructions KFG, KFGS

Page 26

Step Key Display5. Display mode

The display mode can be recognized by the lightedLED displays. The LEDs are not flashing!This mode serves for the checkback of currentsettings and operating parameters.Always start the display mode by brieflypressing one of the two keys .

System monitoring is displayed

1

Press shortly

Current operating state is displayedExample: Timer operation pause

2

3

4

5

6

7

Remaining time for pause of current lubricationcycle is displayedExample: 2.6 h

Preset total time of pause is displayedExample: 1 h (setting by factory)

Pump operation time is displayedExample: Timer operation

Example: System is in the pause mode,current tCO display not possible

Preset value is displayedExample: 4 min (setting by factory)

Page 29: Vogel - Operating Instructions

ChapterContents

5

Operating Instructions KFG, KFGS

Page 27

Step Key

or Monitoring by pressureswitch. Not allowed forprogressively-actingsystems!

8

9

10 / 11

13 / 14

12

Monitoringswitched off(setting by factory)

Display of hours run

Example: Part 1 ofthe total valueWrite down !

Example: Part 1 ofthe total valueWrite down !

Display goes offOh and Fh values will unerasably be stored in the EEPROM.

15

Part 2 of the total valueTotal value: 00533.8 hMaximum value: 99999.9 h

Display of fault hours

Part 2 of the total valueTotal value: 00033.8 hMaximum value: 99999.9 h

or Monitoring bycycle switch

Display

Page 30: Vogel - Operating Instructions

ChapterContents

6

Operating Instructions KFG, KFGS

• Programming always starts withthe steps 1 – 2 !

• The programming mode can be recognizedby the flashing display.

6.1 Start of programming mode

6.2 Alteration of times for lubrication interval

Carry out steps 1 to 2!

Note for step 2:

If the code 000 set by the factory was altered, thenthe altered code has to be selected withthe keys and needs to be confirmed withthe key.

Alterations will be written into the memory andthe display will go off.

9

Page 28

6. Programming Step

Press SETlonger than 2s

000 display is flashing(code 000 is the setting by the factory)

Automatic display of the firstparameter, i.e. „pause in timeroperation“. The „pause“ LED isflashing

Press SET shortly(confirm code)

1

2

Press SET shortly

Pause time 1 h(setting by factory)

Set new valueExample: 6.8 h = 6 h 48 min

3

4

Press SET shortly,confirm new value

Press SET shortly

5

6

Display of the next parameter, i.e.„pump operation time in timeroperation“The „Contact“ LED is flashing

Set new valueExample: 3 min

Pump operation time 4 min(setting by factory)

7

Confirm new value8

Press SETlonger than 2s

Press SET shortly

Key Display

Page 31: Vogel - Operating Instructions

ChapterContents

6

Operating Instructions KFG, KFGS

Page 29

6.4 Alteration of operating modesCarry out steps 1 to 2!

6.3 Alteration of system monitoringCarry out steps 1 to 2!

Monitoring by cycleswitch, i.e. LED „CS“is flashing.

Press until:

Pressoptionally until:

or Monitoring bypressure switchNot allowed forprogressively-actingsystems !

Step Key Display

Start of monitoringsettings is displayed.

3

System monitoring isswitched off(setting by factory)

4

Press SETlonger than 2s

New settings will be written into the memoryand the display will go off.

5

Step Key Display

Change from pause timeto counter operation (onlypossible with externalelectric pulse generatorValues in pulses

3

Press SETshortly to confirmcounter operation

Display of pumpoperating time in timeroperation

4

Change from pumpoperating time tocounter operation(special purposefunction)

5

Press SET shortly

7

Confirm new settings6

Press SET shortly

7

Press SETlonger than 2s

New settings will be written into the memoryand the display will go off.

Confirm new settings6

Press SET shortly

Page 32: Vogel - Operating Instructions

ChapterContents

6

Operating Instructions KFG, KFGS

Step Key Display

Page 30

Confirm new code

3

4

7 Press SETlonger than 2s

Press SETshortly until

New code will be written into the memory andthe display will go off.

Press SET shortly(confirm code)

Press SET shortly(confirm key)

Display is flashingCode 000(setting by factory)

5

6

Display is flashing

New codeExample: 666

Attention! Do not enter 321

Display is flashing1

Select key number(setting by factory)

Press SETlonger than 2s

2

The code preset by the factory is now deleted and the new code is valid.Write down the new code and keep it in

a safe place. If the code gets lost, programmingof parameters will not be possible then. Thepump set needs to be sent to the dealer or theauthorized Vogel branch office.

Attention:Do not enter the digits 321 as the new code.

6.6 Programming ranges

Function Programming range

Pause time 0.1 h to 99.9 hPump operatingtime 0,1. min to 99.9 minPulses 1 to 999

6.7 Display ranges

Display Display range

Fault hours 0.1 h to 99,999.9 hHours run 0.1 h to 99,999.9 h

6.5 Alteration of code

Operate appropriatekey until

Operate appropriatekey until

Page 33: Vogel - Operating Instructions

ChapterContents

7

Operating Instructions KFG, KFGS

7.1 Timer operationPause and pump operating time are time-dependent.

Set tPA and tCO in the programming mode.

The time-dependent, preset values for PAUSE andCONTACT control the lubrication cycle.

PAUSE: values in hours

CONTACT: values in minutes

Page 31

7.2 Counter operationPause is dependent on number of pulsesPump operation is time-dependent

Set cPA and tCO in the programming mode.An external pulse generator needs to be

connected as described in Paragraph 3.5,page 17.

PAUSE: values in pulses

CONTACT: values in minutes

Operation in machines

A switch is opened and closed in dependence ofmechanical movements, revolutions, etc. Whenthe preset value of the pulses cPA to be countedhas been reached, lubrication will be released.

Operation in vehicles

only for trailers and semi-trailers

Lubricating operation without system monitoringCOP = OFF

The pump set is not equipped with permanentpower supply.

The pump is electrically connected withthe stop light circuit.

Please observe regional regulations forinstallation!

The control device counts the brake signals duringthe PAUSE. When the preset value of the pulsescPA to be counted has been reached, lubricationwill be released.

Braking times of a vehicle are usually smaller thanthe set pump operating time tCO (the factorysetting is 4 min).

During the following braking processes the controldevice will perform lubricating operations until theset pump operating time tCO is reached.

After that a new lubrication cycle will start with thepause cPA.

7. Operating modes

Page 34: Vogel - Operating Instructions

In this mode, the lubrication cycle is controlled onlyby the preset values for PAUSE and CONTACT.

Monitoring must be switched off. COP = OFF System trouble will not automatically be

recognized and visualized.

7.4 With system monitoring

In this mode, additional monitoring of the systemfunctions is performed by external switches.

Monitoring can take place for:

• the filling level of the lubricant vessel

• the function of the progressively-acting distributorby means of a cycle switch

System trouble will be recognized and visualized automatically.

Monitoring is switched on. COP = CS

ChapterContents

7

Operating Instructions KFG, KFGS

Page 32

7.5 Monitoring of filling level

If installed, monitoring of the filling levelis active all the time.

If the level in the lubricant vessel falls below theminimum filling level, the lubrication cycle will stopand a fault message will be visualized on thedisplay.

Fig. 14 Fault message

FLL: Fault Low Level

Retrofitting of a pump set with the „Filling level monitoring“ feature, whichdid not have this feature before, is

possible only in the factory. The set needs thento be sent to the factory.

7.3 Without system monitoring

Page 35: Vogel - Operating Instructions

ChapterContents

7

Operating Instructions KFG, KFGS

Possible only for centralized lubricationsystems with progressively-acting distributors.

For greases up to NLGI Class 2.

The cycle switch monitors the movement of thepistons in the progressively-acting distributor duringthe CONTACT time.In the programming mode, the following monitoringfeature must be activated: COP = CS

Page 33

1 set KFGS1-52 lubrication line3 main distributor4 sub-distributor5 friction points6 cycle switch7 electric compartment8 excess pressure valve

7.6 Monitoring by cycle switch

2

7

2

8

1

6

black

4

3

5

2

Fig. 15 Electrical connection of cycle switch

7

Page 36: Vogel - Operating Instructions

ChapterContents

8

Operating Instructions KFG, KFGS

Check the filling level of the lubricant vessel in regular intervals.If the vessel was emptied, the entire

system has to be vented after filling up.

All fault messages are visualized as collective faultmessage by means of the light-emittingdiode. When a fault message is displayed thenormal process of functions is stopped by thecontrol device and the fault occurred will be storedand displayed.The cause of the fault can be read on thedisplay.This makes the fault diagnosis considerablyeasier, but it requires system monitoring.

Page 34

8. Operating trouble

8.1 Display of faults

Start the display mode with the or key

Press until the fault display is reached:

8.2 Deletion of fault messages

All fault messages can be acknowledged and deleted with thiskey. In timer operation, deletion is possible also with an external push-button switch, if installed.

Identify and eliminate the cause of fault before deleting thefault message.The user shall be held liable for damage from vehicle operation without lubrication.

The time, during which the control device and pump set have been run without lubrication, will unerasably be storedin the EEPROM als fault hours Fh.

Display Explanation

Cycle switch fault: Signal from cycle switch not available during pump operating time.(See Chapter 8.5. Block operation)

Fault: Low levelThe filling level in the storage tank has fallen below the minimum level.The further process of functions is stopped.

Page 37: Vogel - Operating Instructions

ChapterContents

8

Operating Instructions KFG, KFGS

Page 35

8.4 Maintenance and repair

The following maintenance works and checks haveto be carried out in regular intervals:

• Checking of filling level in the lubricant vessel

• Regular checking of tightness in the system components

• Visual checking of lubrication state in bearings

• Checking of electric cables for damage

• Checking of electrical connections and contacts

• The basic function of the control device and ofthe system components can be verified by releasing an intermediate lubrication process.

• Checking of electrical connections in the case of fault messages

• Replace defective fuses only with new fuses ofidentical performance

Any works beyond the above scope needto be done by authorized Vogel Serviceestablishments.

The service life of the pump elements decisivelydepends on the purity of the lubricants used.

8.3 Storage of fault times

Faulty-state counter

The time passed from the generation of a faultmessage till its acknowledgement is added inhours.After acknowledgement, this value will automaticallybe recorded by the fault hour meter.

Fault hour meter

The fault hour meter adds all fault-state timesoccurring during the total operation time of the set.The current result of metering can be read in thedisplay mode in two blocks of three digits eachafter calling the parameter Fh (see Chapter 5).

The maximum display capacity of the meter is99,999.9 hours. The smallest interval storable is0.1 hour = 6 minutes.The memory cannot be erased.

Page 38: Vogel - Operating Instructions

ChapterContents

8

Operating Instructions KFG, KFGS

Page 36

Block operation is the reaction of the control deviceto the absence of signal from the cycle switch.Possible causes:

• Defective lubricant lines

• Blocked progressively-acting distributor

• Faulty cycle switch

• Lack of lubricant

No signal available from the cycle switch duringthe pump operation period:

• Abortion of normal operation

• Start of block pause with checkback of cycle switch

No signal available from the cycle switch duringthe block pause:

• Start of second lubrication cycle in block operation

As soon as the signal is received from the cycleswitch, block operation will be aborted and a normallubrication cycle will start with a pause.

A total of three lubrication cycles will be performed with checkback of the cycle switch.

Three pump operation periods and two blockpauses without signal from the cycle switch!Abortion of block operation, display of faultmessage!

Device display

Device Display on the control device

Duration of block pause

Pause in normal Block pause blooperation tPA

0.1 h = 6 min 6 min0.2 h = 12 min 12 min0.3 h and longer 15 min

Identify and eliminate the causeof fault!

CS

8.5 Block operation

Page 39: Vogel - Operating Instructions

ChapterNext

8

Operating Instructions KFG, KFGS

Page 37

Fault Cause Remedy

Pump Stirring arm in the grease storage vessel • Mechanical damage, • Replace pumpdoes not rotate during the activated pump e.g. faulty motor. Take off the lubricant main line at the outlet of the operation period excess pressure valve.

Loosen the electrical connection. Loosen the three fixing screws. Demount the faulty pump. Mount the new pump and connect the lubricant line as well as the electrical cable.Start the system up and carry out function test.Mind the correct values for pause and contact times.

• Electrical connection interrupted • Check or replace fuse.

• Check electrical connections.Check cable set for damage!

Pump without functionwhen pressing the DK key, although all the • Electrical control has failed Replace the pumpelectrical connections are in order • Pump drive / motor is faulty

Pump is not delivering lubricant, although • Lubricant level in the vessel is Fill lubricant vessel up to „max“the stirring arm is rotating below minimum

The non-return valve in the pump Replace the pump elementelement does not close. Note: Dosing marks with grooves(Indication: The outlet can be keptclosed with your fingers when the

main line is taken off.)

• Suction problems due to air Dismantle the pump element and operate the pump by pressinginclusions in the grease the DK key until grease emerges at the outlet of the casing.

8.6 Pump trouble

Page 40: Vogel - Operating Instructions

ChapterContents

8

Operating Instructions KFG, KFGS

Page 38

Fault Cause Remedy

• The pump element does not build Replace the pump elementup pressure. The pump element is Note: Dosing marks with groovesworn out. (Indication: The outletcan be kept closed with your

fingers when the main lineis taken off.)

Excess pressure valve on the pump • System pressure is over 300 bar, Check the system and repair or convert the systemopens and lubricant is emerging e.g. due to distributor blocking or so that the maximum system pressure is 200 bar at 20 °C.

blocked lubrication point

• Valve damaged or soiled, Replace the excess pressure valvetherefore no proper closing

Page 41: Vogel - Operating Instructions

ChapterContents

Operating Instructions KFG, KFGS

Page 39

WILLY VOGEL AGTechnical Sales OfficeSinstorfer Kirchweg 74-9221077 Hamburg

(++49) 40-76 10 28 74 / 75(++49) 40-76 10 28 96

WILLY VOGEL AGTechnical Sales OfficeMöddinghofe 1942279 Wuppertal

(++49) 202-64 10 81(++49) 202-64 97 29

WILLY VOGEL AGGottlieb-Daimler-Straße 763128 Dietzenbach

(++49) 60 74-40 96-0(++49) 60 74-40 96-33

WILLY VOGEL AGTechnical Sales OfficeNürtinger Straße 4672622 Nürtingen

(++49) 70 22-5 67 36(++49) 70 22-5 53 32

WILLY VOGEL AGTechnical Sales OfficeDuisburger Straße 4490451 Nürnberg

(++49) 911-6 42 70 94(++49) 911-6 49 15 70

WILLY VOGEL AGTechnical Sales OfficeOtto-Schmerbach-Straße 3009117 Chemnitz

(++49) 371- 8 81 20 61 / 62(++49) 371- 8 81 20 63

WILLY VOGEL AGMotzener Straße 35 / 3712277 Berlin

(++49) 30- 7 20 02-184(++49) 30- 7 20 02-111

Service in Germany

Page 42: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

Page 40

Service worldwide

CROATIA, SLOWENIA

INGENIEURBÜRO R. KROPEJSchloßmühlstraße 162320 Wien-Schwechat

(++43) 1-707 36 58(++43) 1-707 73 69 13

NEW ZEALAND

TRANSCONSULT LTD.P.O. Box 38955HowickAuckland

(++64) 9-576 96 28(++64) 9-576 96 08

THE NETHERLANDS

VOGEL NEDERLAND B.V.Buurserstraat 2187544 RG Enschede

(++31) 53-4 76 51 65(++31) 53-4 77 34 35

E-mail: [email protected]

NORWAY

SHELBY TEKNIKK ASPostboks 230Strandgaten 554379 Egersund

(++47) 51-49 05 00(++47) 51-49 05 80

IRELAND

DRIVERRITETechnical ServicesUnit 10, Parkmore Industrial EstLong Mile RoadDublin 12 Ireland

(+353) 1-4 50 78 33(+353) 1-4 50 97 39

E-mail: [email protected]

ITALY

BERGER VOGEL s.r.l.Via Mambretti, 920157 Milano

(++39) 02-3 32 11 51(++39) 02-33 32 120

E-mail: [email protected]

JAPAN

VOGEL JAPAN LTD.16-20, Hishie 2-chome.Higashi-Osaka CityOsaka 578-0984

(++81) 729- 64 50 55(++81) 729- 65 12 58

E-mail: [email protected]

KOREA

WOO NAM INDUSTRIAL CO. LTD.88B-9L Namdong Industrial ComplexNamdong-kuInchon City

(++82) 32-815 28 00(++82) 32-819 64 66

E-mail: [email protected]

AUSTRALIA,FIJI and PAPUA NEW-GUINEA

FUCHS LUBRITECH(AUSTRALIA) PTY LTD.45-47 Wittenberg Drive, Canning Vale,Perth, WA 6155

(++61) 8-94 55 14 26(++61) 8-94 55 14 22

E-mail: [email protected]

BELGIUM and LUXEMBOURG

WILLY VOGEL BELGIUM BVBADrevandaal 52860 Sint-Katelijne-Waver

(++32) 15-30 69 20(++32) 15-30 69 29

E-mail: [email protected]

DENMARK

POVL MØLLERSMASKINFABRIK A/SKimmerslevvej 34140 Borup

(++45) 57-52 62 62(++45) 57-52 64 70

E-mail: [email protected]

FINLAND

LAHTINEN & RIKSMAN OYSäynäslahdentie 600560 Helsinki

(++358) 9-55 70 41(++358) 9-55 21 45

FRANCE

VOGEL MECAFLUID S.A.Rue Robert Amy49400 Saumur

(++33) 2-41 40 42 00(++33) 2-41 40 42 42

E-mail: [email protected]

UNITED KINDOMand NORTHERN IRELAND

STERLING HYDRAULICS LTD.Sterling House, CrewkerneSomerset TA 18 8LL

(++44) 14 60-7 22 22(++44) 14 60-7 23 34, 7 64 02

E-mail: [email protected]

HONG KONG, CHINA

WEARMAX HOLDINGS LTD.Room 18-20, 2nd Floor, Newport Centre,116-118 Ma Tau Kok RoadKowloon, Hong Kong

(++852) 23 34 87 91(++852) 27 65 05 29

E-mail: [email protected]

INDIA

VOITH INDIA LIMITEDP.O. Industrial EstateNacharamHyderabad - 501 440

(++91) 40-717 35 61, 717 35 92, 717 14 40

(++91) 40-717 11 41E-mail: [email protected]

Page 43: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

Page 41

Service worldwide

SWITZERLAND

MAAG TECHNIC AGSonnentalstraße 88600 Dübendorf 1

(++41) 1-8 24 91 91(++41) 1-8 21 59 09

E-mail:[email protected]

O. MENGFAHRZEUGTECHNINKFlorastraße 53005 Bern

(++41) 31-3 52 64 26(++41) 31-8 19 53 23

H. SCHUOLERFAHRZEUGTECHNIK AGPostfachBirsstraße 544028 Basel

(++41) 61-3 12 37 08(++41) 61-3 12 70 03

ROTECH AGEbriststrasse 48102 Oberengstringen

(++41) 1-7 75 26 26(++41) 1-7 50 02 64

AUSTRIA

HAINZL INDUSTRIESYSTEMEGmbH. & Co. KGIndustriezeile 56Postfach 1004040 Linz

(++43) 732-78 92(++43) 732-78 92-12

E-mail: [email protected]

KARL HALWACHSGES.M.B.H. & CO. KGScheibelgarten 5332870 Aspang

(++43) 26 42-525 24, 529 52(++43) 26 42-521 63

POLANDVOITH POLSKA Sp. z.o.o.Majkòw Duzy 7497-371 Wola Krzysztoporska

(++48) 44-6 46 88 48 bis -53(++48) 44-6 46 85 20

E-mail: [email protected]

SWEDEN

SOMMERS INDUSTRITEKNIK ABBox 110 20Lasbomsgatan58011 Linköping

(++46) 13-15 80 30(++46) 13-15 05 45

E-mail: [email protected]

SINGAPORE, INDONESIA, MALAYSIA,THE PHILIPPINES

OSA Industries Pte. Ltd.63 Jalan Pemimpin # 03-08Pemimpin Industrial BuildingSingapore 577219

(++65) 258-1100(++65) 258- 2525

E-mail: [email protected]

SPAIN, PORTUGAL, MAROCCO

WILLY VOGEL IBERICA, S.A.Avd. de Suiza n° 3Poligono de actividades logisticas28820 Coslada (Madrid)

(++34) 91-6 70 78 00(++34) 91-6 70 78 42

E-mail: [email protected]

SOUTH AFRICA

IMSINDUSTRIAL PRODUCTS (PTY) LTD.P.O.Box 1976Alberton, 1450

(++27) 11-3 89 53 00(++27) 11-3 89 53 10

E-mail: [email protected]

ULTRA-FLOWLUBRICATION SYSTEMS ccUnit 15 Montague ParkStella Road, Montague GardensCape TownSouth Africa, 7441

(++27) 21-5 51 74 96(++27) 21-5 51 74 95

E-mail: [email protected]

TAIWAN

CHANGHUA CHEN YINGOIL MACHINE CO., LTD.9F., 1, Lane 83, Sec. 1,Kuang Fu Road,Sanchung TaipeiTaiwan/R.O.C.

(++886) 2-29 99 46 49(++886) 2-29 99 46 62

E-mail: [email protected]

Glory Way Industrial Co., LTD.3FL. No. 82, Section1,Chung Cheng Road,Shih Lin DistrictTaipeiTaiwan/R.O.C.

(++886) 2-28 35 02 49 / 50(++886) 2-28 36 01 61

E-mail: [email protected]

Page 44: Vogel - Operating Instructions

ChapterNext

Operating Instructions KFG, KFGS

Page 42

Service worldwide

UNITED STATES, CANADA and MEXICO

VOGEL LUBRICATION, INC.P.O. Box. 31008 Jefferson AvenueNewport News, VA 23607

(++1) 757-380-8585(++1) 757-380-0709

E-mail: [email protected]

CZECH REPUBLIC,SLOVAK REPUBLIC

Kandt KGRobert-Koch-Straße 3620249 Hamburg

(++49) 40-48 06 14 30(++49) 40-48 06 14 12

E-mail: @kandt.hamburg.com

LUBTEC s.r.o.Opolany 16228907 Libice nad Cidlinou

(++420) 324-67 75 45(++420) 324-67 71 84

E-mail: [email protected]

TURKEY

HIDROPAKHidrolik-Pnomatic AksamSanayi ve Ticaret ASPerpa Is Merkezi K 11 No. 162080270 Okmeydani

(++90) 212-2 21 12 27/28/29(++90) 212-2 21 74 88

E-mail: [email protected]

HUNGARY, RUMANA, BULGARIA,EX-YUGOSLAVIA, ALBANIA

WILLY VOGEL HUNGARIA Kft.Felvèg u. 4.2051 Biatorbàgy

(++36) 23-312-431(++36) 23-310 441

E-mail: [email protected]

Page 45: Vogel - Operating Instructions

ChapterStart

951-

130-

184