1
Rockwool has a thermal conductivity of 0.044W/mk, C studs secondary structure every 900c/c CHS column supporing curain walling box to sructural engineers specification Curtain walling box to structural engineers specification Plasterboard gyproc Hygienic 12.5mm giving surface of wall a smooth finish and anti bacterial growth, additional specification for Nurses and surgery room to be adapted Fibre cement cladding 12x1250x2500mm cladding bracker allowing bracker to be fixed onto rail track Airflow 12mm Cement Particle board PIR Rigid Ins Rigid Polyurethane Ins Thermal Con: 0.025Wm2K Aluminium secret clip and rail fixed on a rail track carrying cladding loads Plasterboard gyproc Hygienic 12.5mm giving surface of wall a smooth finish and antibacterial growth, additional specification for Nurses and surgery room to be adapted filled rock wool Ins, limiting thermal bridging at cut juncions 12 54 40 50 12 100 43 25 25 100 25 Vapor check membrane glazed into cutain walling 40mm Service zone Rockwool has a thermal conductivity of 0.044W/mk, C studs secondary structure every 900c/c Plasterboard gyproc Hygienic 12.5mm giving surface of wall a smooth finish and anti bacterial growth, additional specification for Nurses and surgery room to be adapted 12mm Cement Particle board PIR Rigid Ins Rigid Polyurethane Ins Thermal Con: 0.025Wm2K Aluminium secret clip and rail fixed on a rail track carrying cladding loads Forticrete rainscreen cladding 35x225x600mm CHS on each side of atrium to support curtain walling- to enginners specification Curtain walling box @ Entrance Bracket between curtin walling and CHS column 35 61 40 50 12 100 43 25 Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 1 : 5 19/04/2016 18:15:00 Wall Plans Project Number 3 Carlow Primary Health Care Centre 22/04/2016 Xhevdet Haliti Dan O Sullivan, Noel Dunne, Mark Duffy A126 1 : 5 Fibre cement Cladding & Curtain walling 2 1 : 5 Forticrete rainscreen cladding atrium 3 1 : 5 Key Plan Wall Plans @ Atrium 4 3D Forticrete cladding and Atrium 1 3D Fibre cement cladding @ Atrium 5 1 : 5 Key Plan Wall plans @ Atrium 6 CHS Column suppoting curtain walling cladding Curtain walling box 24mm curain walling glas filled with argon gass and thermal breaks between joints Intermediate wall internally Gypsum plaster baord fille rockwool ins for acoustic purposes & heat Fibre cement panels 12x1250x2500mm Tegral Forticete rainscreen cladding 35x215x600mm CHS column suppoting curtain walling box GENERAL INFORMATION FORTICRETE CLADDING: GENERAL INFORMATION FIBRE CEMENT CLADDING: Forticrete Rainscree cladding, Stone cladding giving the building any water which penetrates through the cladding and is not taken away can drain down the back of the cladding and out through the bottom. Condensation is controlled by allowing the fabric to breathe and condensation to pass into the ventilated cavity and be taken awayby the updraft within the cavity. supported by a frame, normally aluminium, within the cavity and located back to the structure with brackets and primary fixings. Rainscreen systems rely on ingress of air at the bottom of the cladding - a ventilated cavity not less than 38mm PICTURA Description Pictura is a unique façade panel with a smooth, semi-matt surface with a double acrylic coating and a polyurethane topcoating, UV hardened on the front face to create a strong impact and dirt resistant finish. Benefits This unique Pictura finish provides excellent scratch and chemical resistance and is therefore particularly suited to aggressive environments as well as allowing easier removal of staining including most forms of graffiti paint. 4 Cladding system rail

Wall Plans

Embed Size (px)

Citation preview

Rockwool has a thermal conductivityof 0.044W/mk, C studs secondarystructure every 900c/c

CHS column supporing curain walling boxto sructural engineers specification

Curtain walling box to structuralengineers specification

Plasterboard gyproc Hygienic12.5mm giving surface of wall asmooth finish and anti bacterialgrowth, additional specification forNurses and surgery room to be adapted

Fibre cement cladding12x1250x2500mm

cladding bracker allowingbracker to be fixed ontorail trackAirflow

12mm Cement Particle board

PIR Rigid Ins RigidPolyurethane Ins

Thermal Con: 0.025Wm2K

Aluminium secret clip and rail fixedon a rail track carrying cladding

loadsPlasterboard gyproc Hygienic12.5mm giving surface of walla smooth finish andantibacterialgrowth, additionalspecification forNurses and surgery room tobe adapted

filled rock wool Ins, limiting thermalbridging at cut juncions

1254

4050

1210

043

25

25 100 25

Vapor check membrane glazed intocutain walling

40mm Service zoneRockwool has a thermal conductivityof 0.044W/mk, C studs secondarystructure every 900c/c

Plasterboard gyproc Hygienic12.5mm giving surface of wall asmooth finish and anti bacterialgrowth, additional specification forNurses and surgery room to be adapted

12mm Cement Particle board

PIR Rigid Ins Rigid Polyurethane InsThermal Con: 0.025Wm2K

Aluminium secret clip and rail fixedon a rail track carrying claddingloads

Forticrete rainscreen cladding35x225x600mm

CHS on each side of atrium tosupport curtain walling- to enginnersspecification

Curtain walling box @ Entrance

Bracket between curtin walling andCHS column

3561

4050

1210

043

25

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

1 : 5

19/0

4/20

16 1

8:15

:00

Wall Plans

Project Number 3

Carlow Primary Health Care Centre

22/04/2016

Xhevdet Haliti

Dan O Sullivan, Noel Dunne,Mark Duffy

A126

1 : 5Fibre cement Cladding & Curtain walling2 1 : 5

Forticrete rainscreen cladding atrium3

1 : 5Key Plan Wall Plans @ Atrium4

3D Forticrete cladding and Atrium1 3D Fibre cement cladding @ Atrium5

1 : 5Key Plan Wall plans @ Atrium6

CHS Column suppoting curtain wallingcladding

Curtain walling box

24mm curain walling glas filledwith argon gass and thermal breaks betweenjoints

Intermediate wall internallyGypsum plaster baordfille rockwool ins for acousticpurposes & heat

Fibre cement panels12x1250x2500mmTegral

Forticete rainscreen cladding35x215x600mm

CHS column suppoting curtainwalling box

GENERAL INFORMATION FORTICRETE CLADDING:

GENERAL INFORMATION FIBRE CEMENT CLADDING:

Forticrete Rainscree cladding, Stone cladding giving thebuilding any water which penetrates through the claddingand is not taken away can drain down the back of thecladding and out through the bottom. Condensation iscontrolled by allowing the fabric to breathe andcondensation to pass into the ventilated cavity and betaken awayby the updraft within the cavity.supported by a frame, normally aluminium, within thecavity and located back to the structure with bracketsand primary fixings. Rainscreen systems rely on ingress of airat the bottom of the cladding - a ventilated cavity notless than 38mm

PICTURADescriptionPictura is a unique façade panel with a smooth,semi-matt surface with a double acrylic coating and apolyurethane topcoating, UV hardened on the frontface to create a strong impact and dirt resistant finish.BenefitsThis unique Pictura finish provides excellent scratchand chemical resistance and is therefore particularlysuited to aggressive environments as well as allowingeasier removal of staining including most forms ofgraffiti paint.4

Cladding system rail