1
DESCRIPTION Complete HEU system with exposed manual Royal ® urinal Flushometer and vitreous china urinal fixture. Flush Cycle Model WEUS 1002.1001-0.25 (0.25 gpf/0.9 Lpf) Code: 10021001 This space for Architect/Engineer approval Job Name Date Model Specified Quantity Variations Specified Customer/Wholesaler Contractor Architect The information contained in this document is subject to change without notice. Sloan Valve Company 10500 Seymour Avenue Franklin Park, IL 60131 Phone: 1-800-9-VALVE-9 (982-5839) or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com Copyright © 2013 Sloan Valve Company WEUS-1002.1001 11-13 20 3/4” (527 mm) (Centerline of outlet) 11 1/2” (292 mm) 2 1/4” (57 mm) 4 3/4” (121 mm) 3/4” IPS Supply (DN 20 mm) Centerline of Fixture Centerline of outlet to floor 19” (483 mm) (12” for ADA) Finished Wall Finished Floor 14 1/4” (362 mm) 15 5/8” (397 mm) 12” (305 mm) 16” (406 mm) 24” (610 mm) (17” for ADA) C L C L 17 1/4” (438 mm) Centerline of outlet to floor 19” (483 mm) (12” for ADA) SPECIFICATIONS Quiet, exposed, diaphragm type, chrome plated urinal Flushometer and vitreous china urinal with the following features: Flushometer PERMEX ® Synthetic Rubber Diaphragm with Dual Bypass ADA compliant metal oscillating Non-Hold-Open Handle with Triple Seal Handle Packing ¾” I.P.S. Screwdriver Bak-Chek ® Angle Stop Free spinning Vandal Resistant Stop Cap Adjustable Tailpiece High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex Coupling Nut Spud Coupling and Flange for ¾” Top Spud Sweat Solder Adapter w/Cover Tube and Cast Wall Flange with Set Screw High copper, low zinc brass castings for dezincification resistance Non-Hold-Open Handle, Fixed Metering Bypass and no external volume adjustment to ensure water conservation Flush accuracy controlled by CID ® technology Diaphragm, Handle Packing, Stop Seat and Vacuum Breaker molded from PERMEX ® rubber compound for chloramine resistance Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037/ ASME A112.19.2/CSA B45.1 Fixture Wall hung vitreous china with Integral flushing rim Washdown flushing action ¾” I.P.S. top spud inlet 2” NPT outlet flange • Vandal resistant strainer assembly included All mounting hardware included 100 % factory flush tested • Compliant to the applicable sections of ASME A112.19.2/CSA B45.1 Carrier not included Compliant with Buy American Act when purchased as a combination Efficiency Series Meets the American Disabilities Guidelines and ANSI A117.1 requirements when installed according to these requirements. Model WEUS-1002.1001-0.25 Manual HEU Flushometer and HEU Urinal Fixture NOTE : Plumbing System Requirements √ Minimum Flowing Pressure: 25 PSI √ Maximum Fixture Static Pressure: 80 PSI NOTE: All vitreous china dimensions shown in these drawings are nominal. Dimensions can vary within the tolerances established in the governing ASME A112.19.2/CSA B45.1 standard. Please take this into consideration when planning rough-in and plumbing layouts.

WEUS_10021001_025

Embed Size (px)

DESCRIPTION

URINAL

Citation preview

Page 1: WEUS_10021001_025

DESCRIPTION

Complete HEU system with exposed manual Royal®

urinal Flushometer and vitreous china urinal fixture.Flush CycleModel WEUS 1002.1001-0.25 (0.25 gpf/0.9 Lpf)

Code: 10021001

This space for Architect/Engineer approval

Job Name Date

Model Specified Quantity

Variations Specified

Customer/Wholesaler

Contractor

Architect

The information contained in this document is subject to change without notice.

Sloan Valve Company10500 Seymour AvenueFranklin Park, IL 60131Phone: 1-800-9-VALVE-9 (982-5839) or 1-847-671-4300Fax: 1-800-447-8329 or 1-847-671-4380www.sloanvalve.com

Copyright © 2013 Sloan Valve CompanyWEUS-1002.1001 11-13

20 3/4”(527 mm)

(Centerline of outlet)

11 1/2”(292 mm)

2 1/4” (57 mm)

4 3/4” (121 mm)

3/4” IPS Supply(DN 20 mm)

Centerline of Fixture

Centerlineof outlet to floor

19” (483 mm)(12” for ADA)

Finished Wall

Finished Floor

14 1/4”(362 mm)

15 5/8” (397 mm)12”

(305 mm)

16”(406 mm)

24”(610 mm)

(17” for ADA)

CL

CL

17 1/4” (438 mm)

Centerlineof outlet to �oor

19” (483 mm)(12” for ADA)

Centerlineof outletto floor

19” (483 mm)(12” for ADA)

SPECIFICATIONS

Quiet, exposed, diaphragm type, chrome plated urinalFlushometer and vitreous china urinal with the following features:

Flushometer• PERMEX® Synthetic Rubber Diaphragm with

Dual Bypass• ADA compliant metal oscillating Non-Hold-Open

Handle with Triple Seal Handle Packing• ¾” I.P.S. Screwdriver Bak-Chek® Angle Stop• Free spinning Vandal Resistant Stop Cap• Adjustable Tailpiece• High Back Pressure Vacuum Breaker Flush Connection

with One-piece Bottom Hex Coupling Nut• Spud Coupling and Flange for ¾” Top Spud• Sweat Solder Adapter w/Cover Tube and Cast Wall

Flange with Set Screw• High copper, low zinc brass castings for dezincification

resistance• Non-Hold-Open Handle, Fixed Metering Bypass

and no external volume adjustment to ensure water conservation

• Flush accuracy controlled by CID® technology• Diaphragm, Handle Packing, Stop Seat and Vacuum

Breaker molded from PERMEX® rubber compound forchloramine resistance

• Valve Body, Cover, Tailpiece and Control Stop shall be inconformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037/ ASMEA112.19.2/CSA B45.1

Fixture• Wall hung vitreous china with Integral flushing rim• Washdown flushing action• ¾” I.P.S. top spud inlet• 2” NPT outlet flange• Vandal resistant strainer assembly included• All mounting hardware included• 100 % factory flush tested• Compliant to the applicable sections

of ASME A112.19.2/CSA B45.1• Carrier not included• Compliant with Buy American Act when purchased

as a combination

Efficiency Series

Meets the American DisabilitiesGuidelines and ANSI A117.1 requirementswhen installed according to theserequirements.

Model

WEUS-1002.1001-0.25Manual HEU Flushometer and HEU Urinal Fixture

NOTE: Plumbing System Requirements√ Minimum Flowing Pressure: 25 PSI√ Maximum Fixture Static Pressure: 80 PSI

NOTE: All vitreous china dimensions shown in these drawingsare nominal. Dimensions can vary within the tolerancesestablished in the governing ASME A112.19.2/CSA B45.1standard. Please take this into consideration when planningrough-in and plumbing layouts.