Xe-based detectors: recent work at Coimbra C.A.N.Conde, A.D. Stauffer, T.H.V.T.Dias, F.P.Santos, F.I.G.M.Borges, L.M.N.Távora, R.M.C. da Silva, J.Barata,

Embed Size (px)

DESCRIPTION

Discontinuities in energy resolution Xenon filled detectors exhibit sudden increases in energy resolution whenever a new Xe atomic-shell becomes available for photoionization Monte Carlo 3/21 M L F and w-value are discontinuous Xe MC simulation experimental

Citation preview

Xe-based detectors: recent work at Coimbra C.A.N.Conde, A.D. Stauffer, T.H.V.T.Dias, F.P.Santos, F.I.G.M.Borges, L.M.N.Tvora, R.M.C. da Silva, J.Barata, P.N.B.Neves, J.M.Escada, L.P.M.M.Carita, S.do Carmo, A.Trindade, J.Mariquito, P.J.B.M.Rachinhas Workshop on Xenon-Based Detectors Nov 2009, Berkeley Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH 4 & Xe-CF 4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 Summary The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors 2/21 Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 Discontinuities in energy resolution Xenon filled detectors exhibit sudden increases in energy resolution whenever a new Xe atomic-shell becomes available for photoionization Monte Carlo 3/21 M L F and w-value are discontinuous Xe MC simulation experimental Discontinuities in Fano factor and w-value Monte Carlo w ph w-value and Fano factor F are E xr dependent Reflect photoionization XS ph F ph 4/21 MC experimental Discontinuities in energy linearity & w =E xr /n Mean number n of primary (sub-ionization) electrons produced in Xe as a function of absorbed x-ray energy E xr Monte Carlo 5/21 Is n proportional to E xr ? Energy resolution and Energy linearity E xr > 4782 eV distributions shift to lower n: discontinuity in w & linearity. distributions broaden: discontinuity in F & R int E xr < 4782 eV (L 3 ): M shell vacancy; M-photoelectron (~3500 eV) dominates; E xr > 4782 eV (L 3 ): inner vacancy (L); photoelectron (few eV); various Auger electrons (30eV to ~4000eV). Xe L 3 binding energy = 4782 eV Monte Carlo 6/21 n Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH4 & Xe-CF4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors Research topics Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 High E 0 : Photoelectrons carry most of the photon energy E 0 are scattered mostly forward. have long trajectories in the gas Long trajectories in the gas: energy gain/loss from the drift field is not negligible. Deposited energy is higher (or lower) than E 0. Energy resolution degradation: drift electric-field effects 7/21 60 keV x rays 200 keV x rays Intrinsic curve : accounts for fluctuations in # of primary (sub-ionization) electrons (F Xe =0.17; w Xe =E 0 /n=21.5 eV). Distributions (PENELOPE): for E/p=0.1 to 0.8 Vcm -1 Torr -1 : Spreads vary with drift field ( drift field photon energy Energy resolution degradation: drift electric-field effects Drift field effects: Fluctuations increase with 8/21 Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH4 & Xe-CF4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors Research topics Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 ion exc Electron scattering cross sections in Xe and CH 4 9/21 10/21 Electron scattering cross sections in Xe and CF 4 Electron drift velocities in Xe, Xe-CH 4 and Xe-CF 4 Addition of CH 4 or CF 4 to Xe increases drift velocity Monte Carlo 11/21 where Addition of CH 4 or CF 4 to Xe increases drift velocity decreases longitudinal and transverse electron diffusion 12/21 Monte Carlo Electron diffusion in Xe, Xe-CH 4 and Xe-CF 4 Monte Carlo Addition of CH 4 or CF 4 to Xe increases drift velocity decreases longitudinal and transverse electron diffusion where 13/21 Electron diffusion in Xe, Xe-CH 4 and Xe-CF 4 Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH4 & Xe-CF4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors Research topics Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 Electroluminescence fluctuations in Xe vs Xe-CH 4, Xe-CF 4 decreases EL (n. of excitations, i.e. sc.photons, produced per electron in sc. gap) increases EL fluctuations (CF 4 has catastrophic effect ) The addition of CH 4 or CF 4 to Xe Monte Carlo 14/21 5 cm drift, 1 atm 5 mm, 10 atm Monte Carlo 15/21 Electroluminescence fluctuations in Xe vs Xe-CH 4, Xe-CF 4 Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH4 & Xe-CF4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors Research topics Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 Tertiary-Scintillation Gas Proportional Scintillation Counter TS-GPSC prototype 16/21 TS-GPSC Results Best results obtained for scintillation electric fields just above Xe ionization threshold voltage across GEM-structure below charge multiplication. Typical spectrum 109 Cd source 17/21 R G FWHM 8.2% Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH4 & Xe-CF4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors Research topics Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 Multigrid High Pressure Xe GPSC (Indicated voltages are ideal values) 18/21 primary electrons are produced in the absorption/drift region primary electrons produce secondary scintillation VUV photons along gap between G 1 and G 2 VUV photons release electrons from CsI photocathode at backplane of detector electrons are collected at G 4 giving the detector signal Multigrid High Pressure Xe GPSC Experimental results Pulse amplitude vs G 3 -G 4 potential barrier ( V 34 ) Charge gain vs E/p in scintillation gap 19/21 V3V4 5.4 bar 5 bar 3 bar 1.5 bar E/p (Vcm -1 Torr -1 ) Gain Energy resolution degradation: drift electric-field effects Tertiary-Scintillation Gas Proportional Scintillation Counter New detectors developed at Coimbra: Electron diffusion in Xe, vs Xe-CH4 & Xe-CF4 Multi-Grid HP Gas Proportional Scintillation Counter Electroluminescence fluctuations in Xe, vs Xe-CH 4 & Xe-CF 4 The Gridded Gas Proportional Ionization Counter Discontinuities in energy resolution & linearity of Xe detectors Research topics Detector gas filling: Xe vs Xe-CH 4 & Xe-CF 4 The gridded GPIC: definition of multiplication volume Grid around the anode: ideal to define multiplication volume However, grid diameter too small, unfeasible at 1 atm. Solution: planar microstructure where PIC conventional anode is hemmed in by a close second anode. 20/21 The gridded GPIC - Experimental keV 21/21 R M M R Experimental results with gridded GPIC At the atomic absorption edges, an electric-field triggered discontinuity may become noticeable as the ejected photoelectron tends to have much lower energy after a new atomic shell becomes photoionizable than before. However this non-linearity is only about 4% of the intrinsic non-linearity. Energy resolution degradation: drift electric-field discontinuities at atomic edges Intrinsic discontinuity Drift velocities for electrons in Xe and Xe-CH 4 Monte Carlo Addition of CH 4 or CF 4 to Xe increases drift velocity