E-FORM INSTRUCTIONSTo fill out e-form, click and type in highlighted form field areas. Use the e-mail button on page 2 to send it. If preferred, you can print this form, fill it out by hand and fax it to us at the number listed above.
To ensure proper installation of your new Safe-T-Lock, please complete the information on page 2.
Elevator Manufacturer:
GO#: (GO# if Schindler, Westinghouse or Haughton)
Job Name:
Job City:
Job State/Province:
Control Type:
Building Name:
Car Number:
Company:
Contact Name:
Contact E-mail:
Order #: P.O. #:
Phone: Fax:
Ship-To Address:
Order Notes:
SAFE-T-LOCK WORKSHEET
More Parts Delivered Faster
CUSTOMER INFORMATIONELEVATOR INFORMATION
Door Not Fully Closed Fault Detection: This type of fault indicates the car gate switch and/or hoistway door lock are closed but the car door is not physically fully closed.
Shorted Door Lock of Car Gate Switch Fault Detection: This type of fault indicates inconsistent performance of the door fully open signal, car gate switch, hoistway door lock, inspection and Fire Phase 2 signals.
Hardware Failure Detection: Safe-T-Lock Monitor monitors itself against hardware failure for redundant protection.
• ADAMS Safe-T-Lock Monitor complies with Section 3.10.12 of theNew York City Building Code and ASME A17.3.
• All hardware is packaged inside a NEMA 4 enclosure and has a UL/CUL508 rating.
• Safe-T-Lock Monitor is a PLC based design, that includes a displayscreen to indicate monitor status and specific door fault codes fortrouble shooting.
• Safe-T-Lock Monitor includes a terminal block system to easilyinterface an existing elevator controller.
• Designed to work with most any controller on the market. Primarysignals required are Car Gate Switch (CGS), Hoistway Door Lock(HDL), Door Fully Open (DFO), Door Fully Closed (DFC), Automatic andInspection mode and Fireman’s Phase 2 (FR2) where permitted by code.
• Variability in elevator control system voltages is addressed throughthe selection of corresponding coil voltages of eight interface relaysmounted inside the Safe-T-Lock Monitor enclosure.
FAULT DETECTION TYPES
KEY PRODUCT FEATURES
p 1.800.929.9247f 1.312.348.6163e [email protected] adamselevator.com/safe-t-lock
Page 1 of 2
CONTROL TYPE
MONITOR RELAY FOR: (Choose Front Only OR Front and Rear, then choose ONE voltage option per category needed.)
EPOCH 2
Miconic A
Westinghouse Relay Control
West TTL
Front Door Only – 7036C84G01 Front and Rear Door – 7036C84G02
West Relay Hydro
PHC Hydro
World Class
EPOCH 1
MPH 1
MPH 2
Car Door Switch Relay circuit (CGS)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
SAFE-T-LOCK WORKSHEET
More Parts Delivered Faster
Hoistway Door Lock Relay circuit (HDL)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Door Fully Open limit circuit (DFO)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Door Fully Closed limit circuit (DFC)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Fire Phase 2 circuit (FR2)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Automatic/Inspection Relay circuit (AUT1, AUT2)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Access Relay circuit (if present) (ACC)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Front Car Door Switch Relay circuit (CGS)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Front Hoistway Door Lock Relay circuit (HDL)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Rear Car Door Switch Relay circuit (RCGS)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Rear Hoistway Door Lock Relay circuit (RHDL)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Front Door Fully Open limit circuit (DFO)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Front Door Fully Closed limit circuit (DFC)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Rear Door Fully Open limit circuit (RDFO)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Rear Door Fully Closed limit circuit (RDFC)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Automatic/Inspection Relay circuit (AUT1, AUT2)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Fire Phase 2 circuit (FR2)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Access Relay circuit (if present) (ACC)
120VAC
125VDC
24VDC
24VAC
48VDC
48VAC
230VAC
110VDC
Page 2 of 2CLICK TO PRINTCLICK TO E-MAIL