S
Automation and Drives
INAMICS S120
Cabinet Modules – System Presentation
A&D LD IM TS, M. Finger
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 2 © Siemens AG 2006 - We reserve the right to make
changes
Line Module
Motor Module
24-VTerminals
adaptor
DC link bracket
24-VPlug-in jumper
Motor Module
Rearranged DC link busbars
In small ones….
S120 Cabinet Modules – The idea
Simple plug-in, reliable connectionsSimple, secure DC link conductor bars
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 3 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules – The idea
Motor Module
Motor Module
…as well as in large onesMotor Module
LineModule
Simple plug-in, reliable connectionsSimple, secure DC link conductor bars
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 4 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules – The idea
The idea:
- Creating a new standard for industry which is based on the new generation- Quality ensured by type tests- Standardised HW interfaces- Minimizing variance- Customer specific group of options
Outcome:
- Type tested, MLFB standard units - High quality ensured by series production - Easy to maintain design - Footprint optimisation
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 5 © Siemens AG 2006 - We reserve the right to make
changes
Connector-bridge for DC link
S120 Cabinet Modules, Operation: Standardized interfaces
Small cabinets – simple operation.
During development the chain of utilization was adhered to: Assembly Commissioning Service
Simple operation, simple assembly
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 6 © Siemens AG 2006 - We reserve the right to make
changes
Plug-in jumper for auxiliary busbar
S120 Cabinet Modules, Operation: Standardized interfaces
Simple and quick wiring
Auxiliary busbar system
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 7 © Siemens AG 2006 - We reserve the right to make
changes
Cabinet internal connections
Connections on the
customer side
X1 X2 X4 X5
X3
X10
The terminals -X1, -X2 and -X3 are for internal use only.
The terminal strip contains: With CU320 (K90) Without CU320 Terminal strip
- 8 digital inputs X -X4, -X5
- 8 bidirectional in/outputs ( DI/DO) X -X4, -X5
- Temperature sensor terminal ( KTY84) X -X5
- Auxiliary voltage output +24 V X X -X10
- Terminals for „STO“ and „SS1” X X -X4
S120 Cabinet Modules, Operation: Customer‘s terminal strip
Each Motor Module Chassis as well as modules with Control Units have a standardized interface within the terminal area according to the requirements of the system integration.
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 8 © Siemens AG 2006 - We reserve the right to make
changes
Each option has a fixed position
S120 Cabinet Modules, Interfaces: Options
Options: Type tested and standardized
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 9 © Siemens AG 2006 - We reserve the right to make
changes
What Cabinet Modules are available?
Line Connection Modules Line Infeed Modules
Basic Line Module Smart Line Module Active Line Module + Active Interface Module
Motor Modules - Chassis format Motor Modules - Booksize format Central Braking Modules Cabinets for the auxiliary power supply Motor-side filter/reactor cabinets
S120 Cabinet Modules – Overview
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 10 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules Basics of Cabinet
Basic layout of Cabinet Modules
Cabinet system Rittal TS8, 2200 mm high
Degree of protection IP20 PE bars (nickel-plated) Coating RAL 7035 Bottom panel (divided into three) Air duct through the door Without side panels
Without DC busbars (mandatory – option) Without Control Unit CU320 Auxiliary busbar system (6 phase) underneath in cabinet Each Cabinet Module is supplied separately (individual order)
Customer‘s documents specific to the order
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 11 © Siemens AG 2006 - We reserve the right to make
changes
Mo
tors
SINAMICS S120 Cabinet Modules
3 AC
main
s
System components SINAMICS S120 Chassis and Cabinet Modules
Line Modules:
ALM, SLM, BLM
Components on the line side
Current supply
DC link components
Control Units
Motor Modules
SINAMICS S120 Chassis and system components
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 12 © Siemens AG 2006 - We reserve the right to make
changes
Overview - SINAMICS S120 Cabinet Modules
Typical plant/system configuration
Lin
e C
on
nec
tio
n
Mo
du
le
Lin
e In
feed
Au
xilia
ry P
ow
er
Su
pp
ly M
od
ule
Mo
tor
Mo
du
les
- C
has
sis
- B
oo
ksiz
e
Mo
tor
Mo
du
les
- C
has
sis
- B
oo
ksiz
e
Ou
tpu
t sw
itch
Cen
tral
Bra
kin
g
Mo
du
le
CU
320
/ Sim
oti
on
ce
ntr
ally
arr
ang
ed
Can be variably combined just as the plant/system demands it
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 13 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Infeed: Basic Line Module (BLM)
Overview, Cabinet Module versions
Auxiliary Power
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 14 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Infeed: Basic Line Module (BLM)Order number Frame-
size Infeed power
rating DC link current rating Infeed current
rating
IN
Weight
Standard design
Dimensions
IP20 2)
W x D x H
kW A A kg mm
Supply voltage
380–480V
6SL3730-1TE34-2AA0 FB 200 420 365 166 400 x 600 x 2200
6SL3730-1TE35-3AA0 FB 250 530 460 166 400 x 600 x 2200
6SL3730-1TE38-2AA0 FB 400 820 710 166 400 x 600 x 2200
6SL3730-1TE41-2AA0 GB 560 1200 1010 320 400 x 600 x 2200
6SL3730-1TE41-2BA0 GB 560 1200 1010 440 600 x 600 x 2200
6SL3730-1TE41-2BC0 GB 560 1200 1010 480 600 x 600 x 2200
6SL3730-1TE41-5AA0 GB 710 1500 1265 320 400 x 600 x 2200
6SL3730-1TE41-5BA0 GB 710 1500 1265 440 600 x 600 x 2200
6SL3730-1TE41-5BC0 GB 710 1500 1265 480 600 x 600 x 2200
6SL3730-1TE41-8AA0 GD 900 1880 1630 320 400 x 600 x 2200
6SL3730-1TE41-8BA0 GD 900 1880 1630 440 600 x 600 x 2200
6SL3730-1TE41-8BC0 GD 900 1880 1630 480 600 x 600 x 2200
Supply voltage
660 – 690 V
6SL3730-1TH33-0AA0 FB 250 300 260 166 400 x 600 x 2200
6SL3730-1TH34-3AA0 FB 355 430 375 166 400 x 600 x 2200
6SL3730-1TH36-8AA0 FB 500 680 575 166 400 x 600 x 2200
6SL3730-1TH41-1AA0 GB 900 1100 925 320 400 x 600 x 2200
6SL3730-1TH41-1BA0 GB 900 1100 925 440 600 x 600 x 2200
6SL3730-1TH41-1BC0 GB 900 1100 925 480 600 x 600 x 2200
6SL3730-1TH41-4AA0 GB 1100 1400 1180 320 400 x 600 x 2200
6SL3730-1TH41-4BA0 GB 1100 1400 1180 440 600 x 600 x 2200
6SL3730-1TH41-4BC0 GB 1100 1400 1180 480 600 x 600 x 2200
6SL3730-1TH41-8AA0 GD 1500 1880 1580 320 400 x 600 x 2200
6SL3730-1TH41-8BA0 GD 1500 1880 1580 440 600 x 600 x 2200
6SL3730-1TH41-8BC0 GD 1500 1880 1580 480 600 x 600 x 2200
Intended for parallel connection
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 15 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Infeed: Smart Line Module (SLM)
Overview, Cabinet Module versions
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
Auxiliary Power
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 16 © Siemens AG 2006 - We reserve the right to make
changes
Order No. Frame size
Rated power
Rated DC link current Line current
Weight,
standard version
Dimensions
IP20 2)
W x D x H
[kW] [A] [A] [kg] [mm]
Supply voltage 380–480V
6SL3730-6TE35-3AA0 GX 250 550 463 270 400 x 600 x 2200
6SL3730-6TE37-3AA0 GX 355 735 614 270 400 x 600 x 2200
6SL3730-6TE41-1AA0 HX 500 1050 883 490 600 x 600 x 2200
6SL3730-6TE41-1BA0 HX 500 1050 883 490 600 x 600 x 2200
6SL3730-6TE41-1BC0 HX 500 1050 883 490 600 x 600 x 2200
6SL3730-6TE41-3AA0 JX 630 1300 1093 775 800 x 600 x 2200
6SL3730-6TE41-3BA0 JX 630 1300 1093 775 800 x 600 x 2200
6SL3730-6TE41-3BC0 JX 630 1300 1093 775 800 x 600 x 2200
6SL3730-6TE41-7AA0 JX 800 1700 1430 775 800 x 600 x 2200
6SL3730-6TE41-7BA0 JX 800 1700 1430 775 800 x 600 x 2200
6SL3730-6TE41-7BC0 JX 800 1700 1430 775 800 x 600 x 2200
Supply voltage 660 – 690 V
6SL3730-6TG35-5AA0 GX 450 550 463 270 400 x 600 x 2200
6SL3730-6TG38-8AA0 HX 710 900 757 550 600 x 600 x 2200
6SL3730-6TG38-8BA0 HX 710 900 757 550 600 x 600 x 2200
6SL3730-6TG38-8BC0 HX 710 900 757 550 600 x 600 x 2200
6SL3730-6TG41-2AA0 JX 1000 1200 1009 795 800 x 600 x 2200
6SL3730-6TG41-2BA0 JX 1000 1200 1009 795 800 x 600 x 2200
6SL3730-6TG41-2BC0 JX 1000 1200 1009 795 800 x 600 x 2200
6SL3730-6TG41-7AA0 JX 1400 1700 1430 795 800 x 600 x 2200
6SL3730-6TG41-7BA0 JX 1400 1700 1430 795 800 x 600 x 2200
6SL3730-6TG41-7BC0 JX 1400 1700 1430 795 800 x 600 x 2200
Intended for parallel connection
S120 Cabinet Modules - Infeed: Smart Line Module (SLM)
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 17 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Infeed: Active Infeed = Active Line Module + Active Interface Module
Overview, Cabinet Module versions
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
Auxiliary Power
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 18 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Infeed: Active Line Module + Active Interface Module (ALM)
Dimensions
IP20
Order No. Frame size
Rated infeed/regenerative feedback power
Rated DC link current Rated infeed/regenerative feedback current
IN
Weight,
standard version W x D x H
kW A A kg mm
Supply voltage 380 – 480 V
6SL3730-7TE32-1BA0 FX+FI 132 235 210 500 800 x 600 x 2200
6SL3730-7TE32-6BA0 FX+FI 160 291 260 500 800 x 600 x 2200
6SL3730-7TE33-8BA0 GX+GI 235 425 380 640 800 x 600 x 2200
6SL3730-7TE35-0BA0 GX+GI 300 549 490 640 800 x 600 x 2200
6SL3730-7TE36-1BA0 HX+HI 380 678 605 930 1000 x 600 x 2200
6SL3730-7TE38-4BA0 HX+HI 500 940 840 930 1000 x 600 x 2200
6SL3730-7TE41-0BA0 JX+JI 630 1103 985 1360 1400 x 600 x 2200
6SL3730-7TE41-0BC0 JX+JI 630 1103 985 1360 1400 x 600 x 2200
6SL3730-7TE41-4BA0 JX+JI 900 1574 1405 1360 1400 x 600 x 2200
6SL3730-7TE41-4BC0 JX+JI 900 1574 1405 1360 1400 x 600 x 2200
Supply voltage 660 – 690 V
6SL3730-7TH35-8BA0 HX+HI 560 644 575 930 1000 x 600 x 2200
6SL3730-7TH37-4BA0 JX+JI 800 823 735 1360 1400 x 600 x 2200
6SL3730-7TH37-4BC0 JX+JI 800 823 735 1360 1400 x 600 x 2200
6SL3730-7TH41-0BA0 JX+JI 1100 1148 1025 1360 1400 x 600 x 2200
6SL3730-7TH41-0BC0 JX+JI 1100 1148 1025 1360 1400 x 600 x 2200
6SL3730-7TH41-3BA0 JX+JI 1400 1422 1270 1360 1400 x 600 x 2200
6SL3730-7TH41-3BC0 JX+JI 1400 1422 1270 1360 1400 x 600 x 2200
Intended for parallel circuit configuration (with mirrored design)
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 19 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Motor Module: Chassis format
Overview, Cabinet Module versions
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
Auxiliary Power
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 20 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules - Motor Module: Chassis format
Order No. Frame size
Rated power
Rated DC link current
Rated output current
IN
Base load current
IL
Power to
IH
Basic load current
IH
Weight Dimensions IP20
WxDxH
kW A A A kW A
Supply voltage
380 – 480 V
6SL3720-1TE32-1AA0 FX 110 252 210 205 90 178 145 400 x 600 x 2200
6SL3720-1TE32-6AA0 FX 132 312 260 250 110 233 145 400 x 600 x 2200
6SL3720-1TE33-1AA0 GX 160 372 310 302 132 277 286 400 x 600 x 2200
6SL3720-1TE33-8AA0 GX 200 456 380 370 160 340 286 400 x 600 x 2200
6SL3720-1TE35-0AA0 GX 250 588 490 477 200 438 286 400 x 600 x 2200
6SL3720-1TE36-1AA0 HX 315 726 605 590 250 460 490 600 x 600 x 2200
6SL3720-1TE37-5AA0 HX 400 894 745 725 315 570 490 600 x 600 x 2200
6SL3720-1TE38-4AA0 HX 450 1008 840 820 400 700 490 600 x 600 x 2200
6SL3720-1TE41-0AA0 JX 560 1182 985 960 450 860 700 800 x 600 x 2200
6SL3720-1TE41-2AA0 JX 720 1512 1260 1230 560 1127 700 800 x 600 x 2200
6SL3720-1TE41-4AA0 JX 800 1686 1405 1370 720 1257 700 800 x 600 x 2200
Supply voltage
660 – 690 V
6SL3720-1TH28-5AA0 FX 75 102 85 80 55 76 145 400 x 600 x 2200
6SL3720-1TH31-0AA0 FX 90 120 100 95 75 89 145 400 x 600 x 2200
6SL3720-1TH31-2AA0 FX 110 144 120 115 90 107 145 400 x 600 x 2200
6SL3720-1TH31-5AA0 FX 132 180 150 142 110 134 145 400 x 600 x 2200
6SL3720-1TH31-8AA0 GX 160 210 175 171 132 157 286 400 x 600 x 2200
6SL3720-1TH32-2AA0 GX 200 258 215 208 160 192 286 400 x 600 x 2200
6SL3720-1TH32-6AA0 GX 250 312 260 250 200 233 286 400 x 600 x 2200
6SL3720-1TH33-3AA0 GX 315 396 330 320 250 280 286 400 x 600 x 2200
6SL3720-1TH34-1AA0 HX 400 492 410 400 315 367 490 600 x 600 x 2200
6SL3720-1TH34-7AA0 HX 450 558 465 452 400 416 490 600 x 600 x 2200
6SL3720-1TH35-8AA0 HX 560 690 575 560 450 514 490 600 x 600 x 2200
6SL3720-1TH37-4AA0 JX 710 882 735 720 560 657 700 800 x 600 x 2200
6SL3720-1TH38-1AA0 JX 800 972 810 790 720 724 700 800 x 600 x 2200
6SL3720-1TH38-8AA0 JX 900 1092 910 880 800 814 700 800 x 600 x 2200
6SL3720-1TH41-0AA0 JX 1000 1230 1025 1000 900 917 700 800 x 600 x 2200
6SL3720-1TH41-3AA0 JX 1200 1524 1270 1230 1000 1136 700 800 x 600 x 2200
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 21 © Siemens AG 2006 - We reserve the right to make
changes
Overview, Cabinet Module versions
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
Auxiliary Power
S120 Cabinet Modules - Motor Module: Booksize Base Cabinet
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 22 © Siemens AG 2006 - We reserve the right to make
changes
Single Motor Modules For output currents up to 200A
Double Motor Modules Space-saving version for 2 motors For output currents up to 18A
100 mm50 mm 150 mm 200 mm 300 mmModule width
Supply voltageRated output current (A) 3 5 9 18 30 45 60 85 132 200 3 5 9 18Maximum output current (A) 6 10 18 36 56 85 113 141 212 282 6 10 18 36Width (mm) 50 50 50 50 100 150 150 200 300 300 50 50 50 100Height (mm)Depth (mm)Degree of protectionCoolingAmbient temperature
Internal/external air cooling, Cold Plate cooling0-40°C without derating, up to 55°C with derating
Motor ModulesSingle Double
510-720V DC
380270IP20
S120 Cabinet Modules - Motor Module: Booksize format - versions
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 23 © Siemens AG 2006 - We reserve the right to make
changes
Motor Module
Motor Module
24-V Terminal adaptor
DC link bracket
24-V Plug in jumper
24-VConductor bars
Motor Module
DC link adaptor
DC link conductor bars
DRIVE CLiQCable
S120 Cabinet Modules - Motor Module: Booksize format – Internal interfaces
high variability = high variancehigh variability = high variance
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 24 © Siemens AG 2006 - We reserve the right to make
changes
Motor connector cable-With crimp contacts-With screws
Motor connector cable- pre-assembled
External built-on fan
Shield connection plate
Motor connector direct with cable lugs
Result:Many components have to be taken into account
Result:Many components have to be taken into account
S120 Cabinet Modules - Motor Module: Booksize format – Internal interfaces
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 25 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules, Design concept
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 26 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules, Design concept: Functional safety
Zone concept:
DC-link
Power section
Output components
Electronic and customer terminals
The components used in a cabinet are influenced by different ambient/environmentconditions.
Solution: Segregation into zones allows safe and reliable operation of all components.
The strict segregation between influencing areas was a core issue when developing the Cabinet Modules.
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 27 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules, Design concept: Functionality and engineering
Design concept:
For example Booksize Base Cabinet
These cabinets can be freely configured with Booksize-kits.All of the components and possible options are arranged within these kits.
The consequence: Engineering and handling is simplified.
Identical design with a high degree of versatility.
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 28 © Siemens AG 2006 - We reserve the right to make
changes
Additional Cabinet Modules
AUX_CI
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
S120 Cabinet Modules – Connection to the mains:Line Connection Module
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 29 © Siemens AG 2006 - We reserve the right to make
changes
Order No.
Frame size
Rated current Dimensions
IP20 4) IN W x D x H
A mm
Supply voltage
380-480V
6SL3700-0LE32-5AA0 FL 250 400 x 600 x 2200
6SL3700-0LE34-0AA0 FL 380 400 x 600 x 2200
6SL3700-0LE36-3AA0 GL 600 600 x 600 x 2200
6SL3700-0LE38-0AA0 HL 770 600 x 600 x 2200
6SL3700-0LE41-0AA0 JL 1000 600 x 600 x 2200
6SL3700-0LE41-3AA0 JL 1250 600 x 600 x 2200
6SL3700-0LE41-6AA0 JL 1600 600 x 600 x 2200
6SL3700-0LE42-0AA0 KL 2000 1000 x 600 x 2200
6SL3700-0LE42-0BA0 KL 2000 1000 x 600 x 2200
6SL3700-0LE42-5BA0 KL 2500 1000 x 600 x 2200
6SL3700-0LE43-2BA0 LL 3200 1000 x 600 x 2200
Supply voltage
660-690V
6SL3700-0LG32-5AA0 FL 280 400 x 600 x 2200
6SL3700-0LG34-0AA0 FL 380 400 x 600 x 2200
6SL3700-0LG36-3AA0 GL 600 600 x 600 x 2200
6SL3700-0LG38-0AA0 HL 770 600 x 600 x 2200
6SL3700-0LG41-0AA0 JL 1000 600 x 600 x 2200
6SL3700-0LG41-3AA0 JL 1250 600 x 600 x 2200
6SL3700-0LG41-6AA0 JL 1600 600 x 600 x 2200
6SL3700-0LG42-0BA0 KL 2000 1000 x 600 x 2200
6SL3700-0LG42-5BA0 KL 2500 1000 x 600 x 2200
6SL3700-0LG43-2BA0 LL 3200 1000 x 600 x 2200
FS H/J FS K/L
S120 Cabinet Modules – Connection to the mains:Line Connection Module
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 30 © Siemens AG 2006 - We reserve the right to make
changes
Additional Cabinet Modules
AUX_CI
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
S120 Cabinet Modules – Performance support: Central Braking Module
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 31 © Siemens AG 2006 - We reserve the right to make
changes
Braking Module in the chassis format (not identical with the Braking Module that can be mounted in the chassis)
Braking power up to 1200 kW Independent control (open-loop) Braking resistor, external
(IP20 degree of protection)
S120 Cabinet Modules – Performance support: Central Braking Module
S120 Cabinet Modules, Central Braking Modules
380V to 480V 500V to 600V 660V to 690V
Contin-uous braking power
Peak power
Contin-uous braking power
Peak power
Contin-uous braking power
Peak power
200 kW 500 kW 225 kW 550 kW 250 kW 630 kW
320 kW 1000 kW 360 kW 1100 kW 400 kW 1200 kW
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 32 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules – Power supply:Auxiliary Power Supply Module
Additional Cabinet Modules
AUX_CI
SITOP
BLMSLMALM
Braking ModuleLCM
M
CU320 / Simotion
CU
32
0
CU
32
0
MM Chassis
MM Booksize
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 33 © Siemens AG 2006 - We reserve the right to make
changes
Auxiliary cabinet
Central fusing/protection of the AUX power supply voltage Generates the 2-ph. 230V AC control voltage
for circuit-breakers, contactors etc. Generates the 24V auxiliary supply
for the other Cabinet Modules Fused/protected power supply
for the unit fans Fused/protected power supply for additional loads
S120 Cabinet Modules – Power supply:Auxiliary Power Supply Module
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 34 © Siemens AG 2006 - We reserve the right to make
changes
Line supply voltage2-ph. 380 V...690 V AC
Control voltage1/N/ 230 V AC
DC voltage2x 24 V DC
Transfer point---->
-Q 3 auxiliarybusbars
-Q 4terminal strip -
X 45
-F 21auxiliarybusbars
-F 22terminal strip -
X47Auxiliarybusbars
6SL3700-
0MX14-0AA0 63 A 50 A 6 A 8 A 20 A
0MX16-3AA0 80 A 63 A 10 A 10 A 40 A
0MX21-0AA0 100 A 80 A 10 A 10 A 80 A
0MX21-4AA0 100 A 80 A 20 A 20 A 80 A
Line supply voltage380-690 V
2-ph. 230 V AC
Auxiliary power rail
Customer terminals-X45
Customer terminals-X47
SITOPCustomer terminals-X46
S120 Cabinet Modules – Power supply:Auxiliary Power Supply Module
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 35 © Siemens AG 2006 - We reserve the right to make
changes
Man
dat
ory
op
tio
nD
ocu
men
tati
on
General options
The options for the S120 Cabinet Modules are sub-divided into general options and module-specific options.
Options
Code Brief option description
L51 Holder for the arc detector
L55 Cabinet anti-condensation heating
M06 Base 100 mm high, RAL 7022 M07 Cable marshalling space 200 mm high, RAL 7035
M21 Degree of protection IP21
M23 Degree of protection IP23 M26 Side panel, mounted at the right
M27 Side panel, mounted at the left
M54 Degree of protection IP54 M59 Cabinet doors closed, air entry from below through an opening in the base plate (floor)
M60 Additional shock hazard protection M80 DC busbars (Id = 1170 A, 1x 60 x 10 mm)
M81 DC busbars (Id = 1500 A, 1x 80 x 10 mm)
M82 DC busbars (Id = 1840 A, 1x 100 x 10 mm) M83 DC busbars (Id = 2150 A, 2x 60 x 10 mm)
M84 DC busbars (Id = 2730 A, 2x 80 x 10 mm)
M85 DC busbars (Id = 3320 A, 2x 100 x 10 mm) M86 DC busbars (Id = 3720 A, 3x 80 x 10 mm)
M87 DC busbars (Id = 4480 A, 3x 100 x 10 mm)
M90 Crane transport hoisting lugs (top mounted) Y09 Special cabinet paint finish
Y11 Assembly of Cabinet Modules in the factory to create transport units
Y31 Labeling plate for plant identification (single-line, 40x80 mm) Y32 Labeling plate for plant identification (two-line, 40x180 mm)
Y33 Labeling plate for plant identification (four-line, 40 x 180 mm)
D02 Customer documentation (circuit diagram, terminal diagram, layout diagram) in DXF format
D14 Preliminary supply of the Equipment Manual (PDF format)
D58 Documentation in English / French
D60 Documentation in English / Spanish D80 Documentation in English / Italian
D99 No documentation T58 Rating plate data in English / French T60 Rating plate data in English / Spanish
T80 Rating plate data in English / Italian
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 36 © Siemens AG 2006 - We reserve the right to make
changes
LCM
Motor Module_C
Module-specific options
Options
Code Brief option description
L13 Main contactor (for Line Connection Modules ¡Â800 A)
L23 Line reactor 2 % for Basic Line Modules
L25 Circuit-breaker, withdrawal type instead of fixed-mounted circuit-breaker (I >800 A)
L41 Current transformer in front of the main switch
L42 Line Connection Module for Active Infeed Modules
L43 Line Connection Module for Basic Line Modules
L45 Emergency Stop pushbutton in the cabinet door
L46 Grounding breaker in front of the circuit-breaker
L47 Grounding breaker after the circuit-breaker
L51 Holder for arc detector (being prepared)
L55 Anti-condensation heating for the cabinet
Code Brief option description
K08 Advanced Operator Panel AOP30, mounted in the cabinet doors
K46 Sensor Module Cabinet-Mounted SMC10
K48 Sensor Module Cabinet-Mounted SMC20
K50 Sensor Module Cabinet-Mounted SMC30
K75 Second auxiliary power busbar system
K80 Terminal module to control the "Safe Torque Off" function
K90 Control Unit CU320 with associated CompactFlash Card without performance expansion
K91 Control Unit CU320 with associated CompactFlash Card with performance expansion 1
L37 DC coupling incl. pre-charging of the associated DC link capacitors
L55 Cabinet anti-condensation heating
L61 Braking unit [braking chopper] 25 / 125 kW
L62 Braking unit [braking chopper] 50 / 250 kW
M70 EMC shield rail
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 37 © Siemens AG 2006 - We reserve the right to make
changes
I 0
S120 Cabinet Modules, Special hardware options: Example: DC coupling
Advantage: Simple and more reliable operation (without maloperation).Advantage: Simple and more reliable operation (without maloperation).
The power unit software checks for the voltage gradient and the voltage magnitude of the DC link. No danger of „overrunning“ the preloading when irregularities occur.
Three-stage circuit breaker with two switch positions (0 – 1)0: OFF: Switch contacts are open1: Preloading: Preloading resistance is switched-in. Preloading is completed in the shortest time.
Operation: When the inverter‘s ON Signal is activated it will be automatically switched to the third position.
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 38 © Siemens AG 2006 - We reserve the right to make
changes
S120 Cabinet Modules, Special options: Everything is possible
Variability is our strength !Variability is our strength !
Example:Booksize cabinets made to order
Application solution:The standard cannot meet every requirement.Should requirements exist which exceed our standard, then the requests for assembly can be carried out by using the regular cabinets as a basis and by using known assembly components.Our application specialists will get in touch with you.
Application solution:The standard cannot meet every requirement.Should requirements exist which exceed our standard, then the requests for assembly can be carried out by using the regular cabinets as a basis and by using known assembly components.Our application specialists will get in touch with you.
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 39 © Siemens AG 2006 - We reserve the right to make
changes
Catalog D21.3CM, preliminary Flyer S120 Cabinet Modules SINAMICS Engineering Manual
Information material
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 40 © Siemens AG 2006 - We reserve the right to make
changes
Highlights (1/2)
Extremely compact design (optimized footprint) Type tested units which match one another
Defined interfaces for power connections and auxiliary supply permit almost any plant/system configuration to be created
Extensive range of options allows tailored multi-motor drives to be created
Short delivery times through Modules that can be ordered by specifying an
Order No. [MLFB] High degree of standardization
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 41 © Siemens AG 2006 - We reserve the right to make
changes
Highlights (2/2)
Increased operational safety and reliability in comparison to normal manufacturing by type tested Cabinet Modules
Order-specific hardware engineering is significantly reduced
Significantly lower logistical costs for order administration for the orderer and the factory
Every Cabinet Module has a number referred to the particular order. This means that an individual list of spare parts can be generated using SparesOnWeb
Automation and Drives
SINAMICS S120 Cabinet Modules
S120 Cabinet Modules – System Presentation 04/2007, Page 42 © Siemens AG 2006 - We reserve the right to make
changes
SINAMICS S120 Cabinet Modules
1. Specify/purchase individual Cabinet Modules
2. OPTION:
Combine cabinet modules in transport sections.
Individual drawings for each cabinet – no interconnections
3. OPTION:
Engineering of line-up with interconnections etc.
Drawings for line-up
Individual drawings for each cabinet – no interconnections