Concrete KickerSupporting FoundationReinforced to Engineers Spec
DPM/Radon barrier
Hollowcore Floor 200mmUsed on Ground fl Level with thebuild up of the floor supported by theconcrete kicker/upstanding
DPM Secured tightly to floor andup around the proprietary Ins
Reinforced Structural screedmixed with polypropylene fibres
Proprietary Ins 50mmLimiting thermal bridging @Floor Junction Internally & Externally-nally
200mm CHS hot rolledsecondary structure to supportStructural glazing
75mm reinforced structuralscreed to engineers specification
Suspended ceiling Held onby C channels
12.5mm Gyproc Plasterboard,Plasterboard to comply with hygienicstandards for health care center
Aluminum spider clamps holdingstructural glazing in place
Aluminum Plate joining CHS columnto structural glazing plate
Structural glazing glass2400x2400mm panel sizes
Expansion bolt tying structuralglazing in place with foundationkicker (Concrete), giving glazingstability
Flashing around glazingstopping excess watergetting inside
Concrete Paver - Sloped 1:50 away from basementventilation boxed to a designated drain
30mm Sand blinding - allowing paving to rest on
Rigid floor insulation
Proprietary Drainage channel
Compacted aggregate base
compacted Subgrade
375
200
200
50 300
200
7515
0
5Structural Glazing 3D
NTS
Steel plate connecting CHSbase to ground and giving itstability
Trench heaingpreventing condensationon structural glazing
Suspended ceiling 600x600mmCorrosive resistant, ceiling type to beapplicable with health care buildingsanti bacterial growth/build up
Steel plate fixed to purling above
Steel Universal I beamcarrying loads transferredfrom roof to ground
Structural steel deck
Hot rolled steel Z profile& rockwool filled insulation &supporting PIR Ins above
Vapor barrier
PIR Rigid Ins Rigid Polyurethane InsThermal Con: 0.025Wm2KLimiting thermal bridging at roof
40mm Halter to suit zinc profile
C channel profile , supportingZinc roof and Ins gutter
Forticrete rainscreen claddingPanel
Air flow ventilationthrough out the building
Spider clamp fitting
Silicone sealant with backer rod
cold rolledoutrigger bolted to Universal I Beamtaking loadsfrom roof
cold rolled outrigger supportingOverhanging
VM Zinc finish
Gutter sloped awayand brought to a drainillustrated
Vapour Barrier
VM Zinc sheet clipVM Zinc continues eavesapronstip & continues folded strip
Light guage steel profilesfilled with rock wool Ins
18mm Marine plywood formingTyvek weather barrier
Zinc pressing
Z profilessupported byC channels
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology CarlowBSc. in Architectural Technology
Year 3 2015-2016
BSc in Architectural Technology Year 3: 2015 - 2016
1 : 5
26/0
4/20
16 2
0:07
:00
Structural Glazing details
Project Number 3
Carlow Primary Health Care Centre
22/04/2016
Xhevdet Haliti
Dan O Sullivan, Noel Dunne,Mark Duffy
A124
1 : 5Structural Glazing @ Ground floor & Intermidiate floor
1
1 : 5Structural Glazing @ Eaves/Roof
2
1 : 5Key Plan section - Structural Glazing
3
200mm CHS hot rolledsecondary structure to supportStructural glazing
perimeter plasterboard corner detailallowing minimal movement
3D Structural Glazing4
1:50