18
PROPORTIONAL COUTER

Proportional counter

Embed Size (px)

Citation preview

Page 1: Proportional counter

PROPORTIONALCOUTER

Page 2: Proportional counter
Page 3: Proportional counter

OBJECTIVESIntroductionconstructionPrincipleOperationWorkingUsesAdvantageDisadvantage

PROPORTIONAL COUNTER

Page 4: Proportional counter

Classification of detectors

Page 5: Proportional counter

o It is a ion collection based detector which is used to Detect the nuclear particles or radiations.

o It is classified in gaseous state detectors

Introduction

Page 6: Proportional counter

CONSTRUCTION

Thin metalic wire strip

Page 7: Proportional counter

o It contains cylinder metallic tube filled with argon and methane gas.

o The ratio of argon and methane gas is 9:1 at one atmospheric pressure .

o Metallic wire (tungsten) act as a anode.o Metallic tube act as a cathode.o The wire is connected to pulse amplifire.

Page 8: Proportional counter

When a particle of low specific ionization passes through an ionisation chamber the pulse produced is too small to be detected.

When applied voltage is increased in chamber is increased it start works in proportinal region.

PRINCIPLE

Page 9: Proportional counter
Page 10: Proportional counter

Operation

E

Where:- V = applied potential difference b = radii of the cylinder a = radii of an axial wire r = distance from the central wire

Page 11: Proportional counter

When a charged particle or radiation such as ᾳ, ᵦ-particle or ϒ-ray photon enters an ionisation chamber, ionisation of gas take place resulting in an ion pair formation.

Positive ion chamber.Electron central

wire.

Page 12: Proportional counter

In this multiplication or gas amplification, the number of ions increases exponentially.this process is cumulative and is called avalanche.

Page 13: Proportional counter

Dependency of avalanche

Radius of anode wire.Radius of tube.Applied voltage.Nature of gas.

Page 14: Proportional counter

The value of gas multiplication factor ‘M’ is give by in this region.

M Here n=number of secondary electrons produced by the primary eletrons. p=the probability of production of photoelectrons.

Page 15: Proportional counter

The shape of the voltage pulse does not depend on the track of the primary ions.

Page 16: Proportional counter

Uses

The proportional counter permits both the counting and energy determination of particles even of very low energy.

It can be used as a spectrometer.They are also used for detection of neutrons,

fission fragments etc.Counting ᾳ-particle in the presence of ᵦ-

particle and ϒ-rays.

Page 17: Proportional counter

Disadvantage

This counter is that the amplification factor depends on the applied voltage.

The applied voltage must be maintained constant within the narrow limit because a slight change in voltage changes the gas amplification.