SCHEDULE OF RATES BUILDING WORKSCONTENTSSECTION (A) (B) (C) (D) (E) (F) (G) (H) (I) (J) (K) (L) (M) (N) (P) (Q) EXCAVATOR CONCRETOR BRICK / BLOCK WORKS PAVIOR ROOFER CARPENTER, JOINER AND IRONMONGER STEEL AND IRONWORKER PLASTERER AND WALL TILER GLAZIER PAINTER ROAD AND CARPARKS DAYWORK PLAY EQUIPMENT AND SITEWORKS CEILING LEAK REPAIRS PILING WORKS MISCELLANEOUS DESCRIPTION SOR PAGE 12 2 14 15 - 22 23 36 36 44 44 64 64 94 95 101 101 - 102 103 109 110 113 114 120 121 129 130 132 132 135 136
ID : KSC/CY/may/BTW(SOR-Preambles).doc(1) (270510) (CD-Rom 2010 Edition)
SOR PREAMBLE Page 1
SCHEDULE OF RATES BUILDING WORKS
GENERAL PREAMBLES
1.
All work materials and goods described in this Schedule of Rates shall be of the respective kinds, described in the Contract and in accordance with the instructions of the Superintending Officer.
2.
The description given of each item, unless otherwise stated, be held to include the use of materials, labour, equipment, tools and vehicles including maintenance, supply of fuel and all idle time, conveyance, delivery, unloading, storing, hoisting, all labour setting, fitting, temporary works, scaffolding and fixing in position, all cutting and waste, return of packings, establishment charges, overheads, profits, shop drawings where necessary and all forms of claims for loss and expense.
3.
Unless otherwise stated, all work shall be measured nett as fixed in its place.
4.
Unless otherwise stated, pipes are described by their internal diameters. The term as specified means as specified in the Standard Specifications, Supplementary Specifications and/or Drawings.
5.
6.
The following abbreviations are used for the units:-
m m m no. ltr pc.
-
Linear metre Square metre Cubic metre Number Litre Piece
kg ton pr sht hr
-
Kilogram Tonne Pair Sheet Hour
7.
The cost of removal and disposal and the making good of all affected works shall be deemed to be included in the Schedule of Rates unless otherwise stated. All Schedule of Rates shall be applicable for new and replacement works.
8.
The Schedule of Rates are deemed to have included the stagings and scaffoldings for repair works up to 6 metres height from the base from which the staging or scaffolding rests. The Contractor shall be paid separately for the staging and scaffolding if the location of the repair works exceeds 6 metre height from the base from which the staging or scaffolding rests.
ID : KSC/TTG/CY/may/BTW(SOR-Preambles).doc(2) (310310) (SanDisk May/129A)
SOR PREAMBLE Page 2
PARTICULAR PREAMBLES TO VARIOUS SECTIONS PART (A) EXCAVATION The measurement of all excavation and subsequent disposal shall be those before excavating. The increases in bulk and any extra excavation required for planking and strutting and formwork for concrete and working spaces under circumstances have been allowed for in the rates. Rates for each item shall be held to include for keeping all excavation free from water and site dry pumping or bailing if required and providing any temporary drains required. Ordinary Ground Includes spoil or rubbish of every description, rubbish tip material etc., sand gravel decomposed granite, red or white earth, loamy or gravelly clay, gravelly laterite, mud, bog or any other formation which is removable by the ordinary application of pick and shovel and at any depth. PART (B) CONCRETOR Unless otherwise specified in the Schedule of Rates: Rates for each item of concrete shall be held to include the followings: (1) Forming, cutting groves, chases, mortice, holes and making good any other sundry items of a like nature. Extra labour for laying to falls, or cambers and preparing surfaces to receive screeds or pavings also to be included. All tests on concrete, cement and aggregate etc., as required and compliance with the strengths as specified. Tamping and/or vibrating to give thorough compaction; working between and around reinforcement. Laying on any type of sub-base, preparing and leaving surfaces to receive screeds or paving.
(2)
(3)
(4)
(5)
Concrete in footpath and apron shall be treated as above ground level.
ID : KMC/mcc/BTW(SOR-Preambles).doc(3)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 3 PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (B) CONCRETOR (CONTD) No deduction shall be made in the measurement of concrete work for: (1) (2) (3) Voids of 0.05 cubic metre or under. Volume of the reinforcement and steelwork. Openings in walls, floor, roof slabs and the like of 0.2 square metre or less.
Rates for mild steel or high tensile steel rod reinforcement shall be held to include for thoroughly wire brushing and cleaning all bars free of rust, dust, mill scale, dirt, oil, any other deleterious matter, cutting to the required lengths, bending and hooking and for securing with an including tying wires at all crossing, non-designed spacers or chairs and distance blocks. No allowance shall be made for rolling margin in the measurement of rod reinforcements. The conversion factor for the various steel reinforcement bars shall be as follows: 6mm 7mm 8mm 9mm 10mm 13mm 16mm 0.222kg/m 0.302kg/m 0.394kg/m 0.499kg/m 0.616kg/m 1.042kg/m 1.579kg/m 20mm 22mm 25mm 28mm 32mm 2.466kg/m 2.984kg/m 3.854kg/m 4.834kg/m 6.313kg/m
Rates for each item of fabric reinforcement shall be held to include for extra material at laps, tying wires and all bending, cutting and notching around obstruction. Only the next area covered shall be measured and no deduction shall be made for opening less than 1.00 square metre. Rates for formwork shall be held to include for splayed edges, notchings, allowances for overlaps and passing at angles, battens, strutting, bolting, welding, easing, wetting and treating with mould oil, striking and removal. The rate in formwork allows for multiple uses where multiple means exceeding two. No deductions shall be made in measurement of formwork for: (1) (2) (3) Openings less than 1 square metre. Intersection of main and secondary beams. Intersection of beams and stanchion casing or columns.
Rates for concrete, reinforcement and formwork shall be applicable to all work irrespective of positions, shapes and height. Rates for each item of precast concrete shall be held to include for all necessary mould, finished faces, forming holes, rebates, sinking, mortices, recesses, hoisting and setting. The measurement of precast concrete vents and grilles shall be held to include for all angles, intersections, ends outlets and extra labour and material for forming grooves and rebates to sides. Piling work shall be executed in accordance with the relevant specifications and Superintending Officers instructions.
ID : KMC/mcc/BTW(SOR-Preambles).doc(4)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 4 PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (C) BRICK AND BLOCK WORKS (CONTD) Rates for each item of blockwork and facing shall be held to include for all special made blocks, bricks and in-situ concrete in lieu, all holdfasts and bonding ties at abutments to concrete structures, all rough and fair cuttings, over-sailing and receding courses, rough relieving and discharging arches, wedging and pining, raking out joints for and pointing flashings, bedding plates, bedding and pointing of frames, parging and coring flues, labour eaves filing, plumbing angles forming square and rebated reveals, cut squiats or birdmouths, notches, forming, leaving or cutting chases, holes and morticles and cutting and pining and making good and any other sundry items of a like nature. Rates of blockwork and brickwork shall be applicable to all work irrespective of positions, shapes and height. Deductions shall be measured the nett sizes of the openings and recesses, including the extra width or rebated reveals. No deductions shall be made for voids not exceeding 0.10 square metre. Deductions shall be made for strings, sills, lintols and the like only when exceeding 75mm in height. Repair Work to External Walls to Prevent Rainwater Seepage. Daywork Should rates be applicable in respect of all work executed on a daywork basis. During the continuance of such work, the Contractor shall keep proper records of the names, occupations and working hours of all workmen employed for such work and the quantities and descriptions of all materials and plant employed. Such records, receipts or vouchers must be verified by the Superintending Officer before payment can be effected. PART (D) - PAVIOR Rates for each item of pavior shall be held to include for all rounded-edges on in-situ paving, all arrises and making good and any other sundry items of a like nature. Rates for each item for skirtings, risers, moulded edges, channels and the like shall be held to include for all short lengths, formed, cut and purpose-made angles, junctions, end etc and making good and any other sundry item of a like nature. No deduction shall be made for a void of 0.50 square meter and under for in-situ paving. In the case of construction of interlocking concrete paving blocks and footpaths, the composite rates shall be applied, unless otherwise decided by the Superintending Officer.
ID : KMC/mcc/BTW(SOR-Preambles).doc(5)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 5 PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (E) ROOFER
The description of each item of roofer shall be deemed to include: (1) All laps, straight, skew and circular cutting at eaves, verges, top edges, abutments, valleys and hips, cutting holes for pipes, nails, screws, clips, pellets, straps and the like. Chasing the structure for burning in or tucking in edges of coverings, flashing and the like. Holes in coverings, underbeds and insulations for pipes, standards and the like and making good. No deduction shall be made for voids of 0.5m2 or less. Rates for Waterproofing Membranes and Secondary Roofing System shall be held to include for narrow widths, small quantities, temporary rules, covering up, protecting after laying and cleaning on completion, all labour to form arises, fair edges etc., all cuttings and working around pipes, dress down at eaves to form drips or carried up at abutments to walls, pipes, parapets, skirtings, concrete curbs etc. and the like. The description of each item of profiled sheet roofing or cladding shall be deemed to include all cutting at square and raking abutments, top edges, bedding and pointing eaves fillers, verges, cutting, fitting and making good around outlets, pipes and any other sundry items of a like nature. PART (F) CARPENTER, JOINER AND IRONMONGER Rates for each item of carpenter and joiner shall be held to include for cutting, notching, boring, sinking, pelleting, fitting, trimming, mitreing, halving, morticing, tenoning, devetailing, scarfing and wedging and for all ends, splayed edges, short lengths, nails, screw and temporary supports and any other sundry item of a like nature. Nominal sizes are stated for wrot timber and an allowance of 2.5mm is permitted for each wrot face. Rate for windows and doors include handing and fixing. Rates for each item of Ironmonger shall be held to include for supply, delivery to site and fixing complete with all matching screws of the same finish as ironmongery, nails, pins or brads, cutting, sinking and boring and morticing as required, oiling and easing and adjusting all moving parts, taking off and refixing after painting where necessary. All references to trade names shall include those which are approved to those as specified. Where ironmongery is included in the description of doors, it shall be deemed to include hinges, floor springs, door gears, locks, latches, catches, bolts, closers, holders, padlocks, stoppers, push-bars and plates, pull bars and handles, kick plates, locking eyes and the like as specified. Rates for Carpenter, Joiner and Ironmonger items shall be deemed to include removal where necessary unless otherwise stated, locks must include 2 keys properly labelled and handed to the Superintending Officer.
(2) (3)
ID : KMC/mcc/BTW(SOR-Preambles).doc(6)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 6 PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (G) STEEL AND IRON WORKER
Rates shall be held to include supply, delivery to site and fixing, cutting ends, welding, riveting, bolting etc. in addition, the rates for structural steel is deemed to also include for hoisting, erecting, temporary bracing, levelling and plumbing, and paint with one coat of primer. No allowance shall be made for rolling margin in the measurement of steelwork. No deduction shall be made for drilling, holes, notchings, splay cuts and the like. Where no conversion table is available from manufacturer/supplier, specific gravity of 7.5 (i.e. 7.50gm/cm3) shall be used to compute the weight of mild steel sections. PART (H) PLASTERER AND WALL TILER Rates for each item of plastering shall be held to include for raking out joints, hacking to form keys, narrow width and small quantities, temporary rules, joints between new and old plastering, internal angles, arrises, quirks, groin points and other intersections and curved surfaces, rounded coves and external angles not exceeding 25mm radius, and mitres, tops, etc. om cornices, mouldings, enrichments, coves, skirtings, gutters and strings, all making good and any other sundry item of a like nature. No deduction shall be made for openings of 0.50 square metre or less. In the measurement of plastering, no deduction shall be made for casings for pipes under 300mm wide or angles which are finished in a different material if these do not exceed 100mm girth. Within the building shall mean surfaces within the internal of buildings/flats, corridors, staircases and the like which normally do not entail scaffolding or mechanical cradles to carry out the works. External face of building shall mean surfaces such as gable end walls, front/back external walls and any other surfaces which are constantly exposed to weather and/or normally require the use of scaffolding or mechanical cradles to carry out the work.
ID : KMC/mcc/BTW(SOR-Preambles).doc(7)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 7
PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (H) PLASTERER AND WALL TILER (CONTD)
Rates for each item of wall tiling shall be held to include for narrow widths and small quantities and fittings around air bricks, pipes and the like and any other sundry item. Rates for each item of terrazzo shall be held to include for narrow widths and small quantities, and for all temporary rules, internal angles, arrises, joints between different types of terrazzo, quirks and making good and any other sundry items of a like nature on in-situ terrazzo fitting around air bricks, pipes and the like and any other sundry items of a like nature on precast terrazzo. Structural Repairs (The following is applicable for H029 H031 only) The rate for each item shall be held to include for: (1) Addition/Replacement of steel reinforcement in concrete components as directed by the Superintending Officer. Removal of finishes/fixtures and other obstruction in the course of repair. The removal of debris from the site in the process of repair or as directed by the Superintending Officer. The cleaning up of site on completion. Provision of barricadings, warning signs and warning lights. Provision of props and formworks as directed by the Superintending Officer. All general risks, liabilities and obligations set forth.
(2) (3)
(4) (5) (6) (7)
ID : KMC/mcc/BTW(SOR-Preambles).doc(8)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 8
PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (I) GLAZIER
Rates for each item of glazier shall be held to include for cutting and rounded edges, puttying, fixing panel pins, brass screws and cup and neoprene strips where necessary and leaving the glass clean on completion.
PART (J) PAINTER
Rates for each item of painting shall be held to include for all necessary preparation of surfaces including cleaning off, sandpapering woodwork, wire-brushing metal and leaving all surfaces free from dust, rust, grease and oil before painting, narrow widths, etc. Rates for painting include allowance for the use of different colours. No deduction shall be made for openings of 0.50 square metre or less.
PART (K) ROADS AND CARPARKS
Rates for each item shall include cost of removal and cost of implementation of precautionary measures where necessary unless otherwise stated.
ID : KMC/mcc/BTW(SOR-Preambles).doc(9)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 9 PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (L) DAYWORKS The following rates shall be applicable to all works executed on a daywork basis including shifting of office equipment and furniture. During the continuance of such works, the Contractor shall keep proper records of the names, occupations and working hours of all workmen employed for such work and the quantities and descriptions of all materials and plant employed. Such records, receipts or vouchers must be verified by the Superintending Officer before payment can be effected. Provided always that if the Superintending Officer shall consider that for any reason the keeping of such records, receipts and vouchers by the Contractor as required was impracticable, he shall nevertheless be entitled to authorise payment for such works either as daywork (being satisfied as to the time employed and plant and materials used on such work) or at such value thereof as he shall consider fair and reasonable. Dayworks Schedule of Rates for LABOUR and PLANTS items only (L001 to L034) is inclusive of 15% Establishment Charge and Profit. The contract percentage adjustment shall also apply. For computation of STAR rate using Dayworks Schedule of Rates, the contract percentage adjustment shall NOT apply to the STAR rates computation. PART (M) PLAY EQUIPMENT AND SITEWORKS Rates for each item shall include cost of removal and implementation of precautionary measures where necessary unless otherwise stated. PART (N) CEILING LEAKS REPAIRS 1. All rates in the Schedule shall include: (a) The provision of all necessary tools equipment, labour, plant, machinery and materials and mobilisation from unit to unit and from block to block; the emergency repairs to be executed immediately beyond the normal working hours and may also beyond constraint boundary. Addition/replacement of steel reinforcement in concrete components as directed by Superintending Officer. Removal of finishes/fixtures and other obstruction in the course of repair. Removal, cut off supply, diversion and reinstatement of water/electrical supply. The removal of debris from the site in the process of repair or as directed by the Superintending Officer. The cleaning up of site on completion. Provision of barricadings, warning signs and warning lights.
(b)
(c) (d) (e)
(f) (g) (h)
Provision of props and formworks as directed by the Superintending Officer (for spalling concrete works only). The provision per unit refers to per unit of flat or shop or office, etc. If the work includes two toilets or bathrooms in the same unit and the total area of work done does not exceed 3.5m, then the Contractor shall only be paid per job. The terms per point means each pipe surround that water leakage repair is carried out. If in a bathroom, the leaking concrete surround the soil pipe, waste pipe and floor trap require repair, the Contractor shall be paid three points.
2.
3.
ID : KMC/mcc/BTW(SOR-Preambles).doc(10)(21/12/2005)(SanDisk May/129A)
SOR PREAMBLE Page 10 PARTICULAR PREAMBLES TO VARIOUS SECTIONS (CONTD) PART (P) PILING WORKS
Piling works shall be executed in accordance with the relevant specifications and the instruction of the Superintending Officer.
The rates shall include the following: (a) (b) The removal of underground obstruction together with all work connection. The transportation, handling, pitching, heading, pointing, bracing and providing protective wrought iron or helmet to pile. The extending pile, dolly and connection. The cutting of surplus and heads of piles, extra excavation, backfilling and disposal of debris. The re-driving or intermittent driving necessitated by upheaving or lengthening of piles or by removal of obstruction under piles or other causes including moving and repositioning the piling frame. The disposal of materials displaced arising out of driving the piles. The assembling of equipment on the site and the subsequent dismantling and removal shall be given separately as an item. The movement of piling frames into position and about the site, any necessary excavation or filling required to place the frames, raising or lowering the frames and any staging, barges or the like required to support the frames.
(c) (d) (e)
(f) (g)
(h)
Payment for treated timber piles driven shall be the product of the relevant rate per metre run and the penetration depth (measured from tip to cut-off level). Payment for each reinforced concrete piles after it is driven into the ground is measured from the cutoff level of the pile to the end of pile shoe. PART (Q) MISCELLANEOUS The miscellaneous works shall be carried out according to the Schedule of Rates description and/or standard drawings, if applicable.
KSC/CY/may/BTW(SOR-Preambles).doc(11)(260510)(CD-Rom 2010 Edition)
SOR Page 1
SECTION CODE
DESCRIPTIONEXCAVATOR (To be read in conjunction with Preambles) Excavation * Excavation oversite commencing from ground level in ordinary ground, including forming of surfaces and removal of surplus excavated materials within site, for the following average overall depth: *(001 003)
UNIT
RATE ($) E M's CODE
A A
001 002
Not exceeding 150mm deep. Execeeding 150mm and not exceeding 300mm deep. Exceeding 300mm deep * Excavate to form trenches for columns, pilecaps foundations, eams, basements, pier holes etc in ordinary ground including forming of bottom, necessary planking and strutting, part return, fill and ram, and remainder get out and deposit on site as directed in stages of the following depth: *(004 005)
m2 m2
1.00 B A 1 1.80 B A 2
A
003
m3
5.40 B A 3
A A
004 005
Not exceeding 2.00m deep Exceeding 2.00m but not exceeding 4.00m deep CART AWAY SURPLUS EXCAVATED MATERIAL off site and deposit at the approved dumping ground. Excavate to pits, small holes etc not exceeding 0.10m3 to receive base of posts, etc including removing surplus excavated material off site and making good. Filling
m3 m3
12.80 B A 4 14.60 B A 5
A
006
m3
4.70 B A 6
A
007
No
6.00 B A 7
A
008
Supply dry approved earth filling obtained from outside source and fill in layers of 300mm including labour for spreading, trimming and consolidating to form earth moulds or levels Supply coarse aggregate (19mm to 38mm gauge), spread and level on site as directed.
m3
10.50 B A 8
A
009
m3
37.20 B A 9
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 2
SECTION CODEA 010
DESCRIPTIONSupply sand, spread, level and consolidate. * SUPPLY HARDCORE IN BEDS, comprising of clean broken bricks/concrete, deposit, spread, levelled, mechanically consolidated and including 25mm thick sand blinding/ topping for the following average thickness from surface level *(011 013)
UNITm3
RATE ($) E M's CODE65.20 B A 10
A A
011 012
Not exceeding 150mm thick. Exceeding 150mm and not exceeding 300mm thick. Exceeding 300mm thick Supply quarry waste/granite fines, spread, levelled, well rammed and consolidated. CONCRETOR (To be read in conjuction with Preambles). Concrete Work
m2 m2
2.30 B A 11 4.70 B A 12
A A
013 014
m3 m3
15.60 B A 13 30.30 B A 14
B
001
Supply and cast Grade 15 lean concrete in beds under foundations, column bases, ground beams etc with 20mm to 10mm graded granite mechanically mixed irrespective of thickness. Supply and cast Grade 20 mass concrete in beds under foundation etc with 20mm to 10mm graded granite mechanically mixed irrespective of thickness
m3
140.00 B B 1
B
002
m3
143.00 B B 2
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 3
SECTION CODE
DESCRIPTION* Supply and cast reinforced concrete in foundations, ground beams, etc with 20mm to 10mm granite mechanically mixed, including formwork and working around rod or fabric reinforcement below ground level (Reinforcement measured separately). *(003 007)
UNIT
RATE ($) E M's CODE
B B B B B
003 004 005 006 007
Grade 20 Grade 25 Grade 30 Grade 35 Grade 40 * Supply and cast reinforced concrete in suspended slabs, beams, columns, staircases, footpath, apron etc with 20mm to 3mm graded granite mechanically mixed and placed around reinforcement above ground level including PVC strip expansion joint where necessary. (Reinforcement and formwork measured separately). *(008 012)
m3 m3 m3 m3 m3
180.00 B B 3 184.00 B B 4 187.30 B B 5 191.00 B B 6 196.00 B B 7
B B B B B B
008 009 010 011 012 013
Grade 20 Grade 25 Grade 30 Grade 35 Grade 40 Supply and cast concrete in SMALL quantities not exceeding 0.15 metre cube to match existing, including all necessary formwork. Extra over Items 008 to 012 for trowelling concrete to footpath, apron etc. Extra over for waterproofing additive in concrete to manufacturer's instructions.
m3 m3 m3 m3 m3 m3
152.00 B B 8 155.00 B B 9 158.40 B B 10 161.90 B B 11 166.60 B B 12 328.00 B B 13
B
014
m2
0.60 B B 14
B
015
m3
25.00 B B 15
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 4
SECTION CODEReinforcement B 016
DESCRIPTION
UNIT
RATE ($) E M's CODE
Supply mild steel rod reinforcement fabricated and laid in position including labour for forming stirrups, links, etc irrespective of size Supply high tensile steel rod reinforcement irrespective of size fabricated and laid in position including labour for forming stirrups, links, etc irrespective of size * Supply and place BRC or other equal and approved welded steel FABRIC REINFORCEMENT well lapped (minimum 1 square) and tied at joints (measured nett) *(018 034)
kg
1.80 B B 16
B
017
kg
1.80 B B 17
B B B B B B B B B B B B B B B B B
018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034
A5 A6 A7 A8 A10 A12 B6 B7 B8 B10 D6 D7 D8 D10 No. 2210 (50 x 50mm x 3.25mm diameter) No. 5515 (12.5 x 12.5mm x 1.5mm diameter) No. 3315 (75 x 75mm x 1.5mm diameter)
m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2
4.75 B B 18 6.40 B B 19 8.25 B B 20 10.80 B B 21 16.80 B B 22 24.20 B B 23 10.70 B B 24 12.30 B B 25 16.20 B B 26 22.20 B B 27 12.80 B B 28 16.50 B B 29 21.60 B B 30 33.60 B B 31 9.40 B B 32 12.80 B B 33 4.50 B B 34
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 5
SECTION CODEFormwork B 035
DESCRIPTION
UNIT
RATE ($) E M's CODE
Supply and erect timber formwork to surfaces of concrete, columns, walls, suspended slabs, stairs, canopies, beams, lintels, etc. (Measured net of concrete surface) Extra over timber formwork for curve surface work. Drain/Water Channel * Construct 230mm wide (internal) CONCRETE (Grade 25) SURFACE DRAIN with 100mm thick sides, 100mm thick base reinforced with a layer of BRC No. B6 wiremesh. All exposed sides, base and arises rendered smooth in cement mortar (1:3) including all necessary excavation, hardcore, sand blinding and formwork, laid to fall as directed for the following average depth to invert: *(037 040)
m2
17.80 B B 35
B
036
m2
3.50 B B 36
B B
037 038
Not exceeding 300mm deep. Exceeding 300mm but not exceeding 450mm deep. Exceeding 450mm and not exceeding 600mm deep. Exceeding 600mm deep Extra over items for precast concrete channel to 230mm wide reinforced concrete surface drain.
m m
46.50 B B 37 60.50 B B 38
B
039
m
74.40 B B 39
B B
040 041
m m
88.40 B B 40 3.40 B B 41
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 6
SECTION CODE
DESCRIPTION* Construct 305mm wide (internal) CONCRETE (Grade 25) SURFACE DRAIN with 100mm thick sides and base reinforced with a layer of BRC No. B6 wire mesh. All exposed sides, base and arises rendered smooth in cement mortar (1:3) including all necessary excavation, hardcore, sand blinding and formwork, laid to fall as directed for the following average depth to invert : *(042 045)
UNIT
RATE ($) E M's CODE
B B
042 043
Not exceeding 300mm deep Exceeding 300mm but not exceeding 450mm deep. Exceeding 450mm but not exceeding 600mm deep. Exceeding 600mm deep Extra Over for Precast Concrete channel to 305mm wide reinforced concrete surface drain. Extra over for forming 50mm x 25mm rebate on both sides of channel for precast drain cover slab (Measurement based on length of drain) Break up concrete/surface drain including cutting reinforcement and removing debris off site. * REPAIRS to 150mm to 305mm wide concrete drain of the following depth to invert; hack off existing rendering at sides and invert of drain, remove damaged or cracked portions of drain, patch up with concrete, form key and re-render drains (whole girth) to proper falls in cement mortar (1:3) *(049 050)
m m
51.10 B B 42 65.30 B B 43
B
044
m
79.50 B B 44
B B
045 046
m m
93.00 B B 45 8.80 B B 46
B
047
m
3.70 B B 47
B
048
m3
77.10 B B 48
B B
049 050
Not exceeding 300mm deep Exceeding 300mm deep but not exceeding 450mm deep
m m
13.60 B B 49 23.50 B B 50
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 7
SECTION CODE
DESCRIPTION* Hack out existing concrete drain invert (Average Depth not exceeding 600mm) and regrade to fall towards outlet with cement mortar screed and finished smooth *(051 052)
UNIT
RATE ($) E M's CODE
B B
051 052
230mm wide 305mm wide * Hack out existing carpark drain invert and regrade drain 450 to 600mm width to fall towards outlet with cement mortar screed and finished smooth *(053 054)
m m
8.80 B B 51 9.60 B B 52
B B
053 054
Average depth not exceeding 800mm Average depth exceeding 800mm * Break up damaged half round precast concrete channels and reconstruct same in cement mortar including laying to proper falls and making good sides of channel *(055 057)
m m
10.50 B B 53 14.00 B B 54
B B B B
055 056 057 058
150mm diameter 230mm diameter 305mm diameter Break up damaged/sunken 300mm closed conduit drain spun pipe include hacking through floor, excavation, planking, making good etc. and reconstruct same jointed in cement mortar to proper fall including lean concrete base * Supply and lay precast concrete composite channel laid to even falls and jointed in cement mortar as detail drawing (EM-TC-STD-BLDG-99-12) *(059 064)
m m m m
18.00 B B 55 20.20 B B 56 25.60 B B 57 79.50 B B 58
B B
059 060
810mm x 495mm - Type C7 595mm x 355mm - Type C7A
m m
44.50 B B 59 34.00 B B 60
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 8
SECTION CODEB B B B B 061 062 063 064 065
DESCRIPTION395mm x 195mm - Type C7B 1200mm x 750mm - Type C8 900mm x 535mm - Type C8A 995mm x 610mm - Type C8B Reconstruct existing scupper drain outside bin chute chamber with new half round salt glazed stoneware pipes, side and base embedded in G20 concrete including adjusting existing gulley to match drain level bedded and jointed with cement mortar * Supply and lay half round salt glazed stoneware pipe in replacement jointed with cement mortar as scupper drain including lean concrete base. *(066 067)
UNITm m m m m
RATE ($) E M's CODE29.20 B B 61 70.90 B B 62 53.60 B B 63 62.50 B B 64 23.90 B B 65
B B B
066 067 068
100mm diameter 150mm diameter Construct scupper drain not exceeding 150mm wide and 75mm deep on existing floor including trowelling surface smooth Regrade existing scupper drain with waterproofing cement mortar laid to fall not exceeding 150mm wide and 75mm deep including trowelling surface smooth Regrade existing scupper drain with waterproofing cement mortar laid to fall exceeding 150mm but not exceeding 300mm wide, 75mm deep including trowelling surface smooth 315mm diameter UPVC pipe conforming to SS272 for concealed drain outlet with Grade 30 concrete bed and reinforced with B6 BRC including formwork and lean concrete (excavation measured separately)
m m m
17.10 B B 66 19.60 B B 67 6.20 B B 68
B
069
m
4.80 B B 69
B
070
m
6.30 B B 70
B
071
m
58.50 B B 71
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 9
SECTION CODE
DESCRIPTIONPrecast Heelstones/Cills/Vents
UNIT
RATE ($) E M's CODE
B
072
Supply and install pre-cast concrete (Grade 25) in heelstones, cills, lintels etc including reinforcement moulds and setting in cement mortar Supply and install pre-cast concrete (Grade 25) in heelstones, cills, lintels etc excluding reinforcement but including moulds and setting in cement mortar Supply and install pre-cast concrete (Grade 25) in designed vents, grilles etc fixed Precast Slabs (Sand Bed Measured Separately) (Pointing between slabs shall not exceed 50mm)
m3
404.10 B B 72
B
073
m3
228.20 B B 73
B
074
m3
462.00 B B 74
B
075
Supply and lay 50mm thick reinforced precast concrete (Grade 25) paving slabs pointed in cement mortar including BRC No. D6 reinforcement * Supply and lay unreinforced precast concrete (Grade 25) PAVING SLABS pointed in cement mortar *(076 077)
m2
42.00 B B 75
B B
076 077
50mm thick 75mm thick * Supply and lay removable precast concrete (Grade 25) cover slab over surface water channel cast in 600mm length with notched handholes at both ends and reinforced with BRC D6 fabric reinforcement *(078 079)
m2 m2
31.40 B B 76 47.00 B B 77
B B
078 079
50mm thick 75mm thick
m2 m2
45.60 B B 78 56.20 B B 79
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 10
SECTION CODE
DESCRIPTION* Supply and lay 50mm thick PRECAST CONCRETE CIRCULAR SLABS with top surface finished with coloured cement rendering including all necessary excavation, if necessary *(080 082)
UNIT
RATE ($) E M's CODE
B B B
080 081 082
300mm in diameter 450mm in diameter 600mm in diameter * Supply and lay 50mm thick precast concrete square slabs with top surface finished with coloured cement rendering including all necessary excavation, if necessary *(083 084)
No No No
4.10 B B 80 7.90 B B 81 11.80 B B 82
B B B
083 084 085
300mm x 300mm 600mm x 600mm Supply and lay 50mm thick grade 25 precast concrete slab 600mm x 300mm with top surface finished with colour washed pebbles including excavation Supply and lay 50mm thick grade 25 precast concrete slab 600mm x 300mm with top surface finished with granite stone including excavation Supply and lay 50mm thick grade 25 precast concrete slab 600mm x 600mm with top surface finished with granite stone including excavation Labour for carefully taking out existing loose or sunken precast concrete slabs and stack aside for re-use. Select from stack and re-use existing precast concrete slab for repairs including jointing in cement mortar 50mm wide and levelling ground
No No No
5.10 B B 83 15.00 B B 84 21.50 B B 85
B
086
No
19.60 B B 86
B
087
No
26.70 B B 87
B
088
m2
2.50 B B 88
B
089
m2
4.60 B B 89
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 11
SECTION CODEB 090
DESCRIPTIONExtra over for pc slab laying on levelled sand bed of 50mm thick Miscellaneous
UNITm2
RATE ($) E M's CODE3.20 B B 90
B B
091 092
Break up concrete Break up concrete, part re-use as hardcore, well rammed, levelled and consolidated and surplus cart away off site, including cutting reinforcement, if any. Cutting through reinforced concrete floors or walls (any thickness) to form openings * Form bituminous expansion joint in concrete floors including all necessary formwork and bituminous seals *(094 095)
m3 m3
77.10 B B 91 84.40 B B 92
B
093
m3
390.40 B B 93
B B B
094 095 096
13mm x 75mm deep 25mm x 100mm deep Form expansion joint with foam plastic infill Rake out existing damaged/worn out Bituminous Expansion Joint in concrete floors and refill same with approved hot bitumen. Supply and plug up bin chute wall holes with 300mm diameter detachable precast concrete complete with 13mm diameter mild steel handle (exclude breaking existing concrete wall) Provide diamond saw-cutting to concrete floor to form 3mm width x 40mm depth (min) contraction joint. Provide diamond saw-cutting to apron slab/drain wall to form 50mm rebate for placing of precast concrete drain cover slab. (Measurement based on rebate length)
m m m2
4.50 B B 94 11.70 B B 95 3.20 B B 96
B
097
m
3.80 B B 97
B
098
No
18.80 B B 98
B
099
m
2.00 B B 99
B
100
m
4.00 B B 100
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 12
SECTION CODEB 101
DESCRIPTIONProvide 100mm wide "Diamond Saw-Cutting" profile around concrete electrode/ lightning protection inspection pit inclusive of the removal of all loosened concrete, casting of new Grade 25 concrete and the trowel smooth all affected areas To provide 150mm long PVC weep hole pipes not exceeding 50mm dia through brick/ concrete work not exceeding 100mm thick Raise or lower existing manhole cover and frame to match the existing level of path or paving Strengthening of Lamp Posts * Strengthen existing lamp post by grouting method using approved pre-packed cement mortar as specified and shown in drawing (EM-TC-STD-BLDG-1003-01) *(104 105)
UNITNo.
RATE ($) E M's CODE15.50 B B 101
B
102
No
3.60 B B 102
B
103
No
17.80 B B 103
B B
104 105
6m high 8m & 10m high * Strengthen existing lamp post in accordance with the method shown in drawing no. LP230302-001C (Case A2) for lamp post planted into the earth at turf area of the following height (with or without arm bracket): *(106 111)
No No
37.00 B B 104 41.80 B B 105
B B B B B B
106 107 108 109 110 111
10m 8m 6m 5m 4 to 4.5m 3 to 3.5m
No No No No No No
100.00 B B 106 91.00 B B 107 80.00 B B 108 73.00 B B 109 69.00 B B 110 64.00 B B 111
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 13
SECTION CODE
DESCRIPTION* Strengthen existing lamp post in accordance with the method shown in drawing no. LP230302-002 (Case B) for planted lamp post on concrete pavement of the following height (with or without arm bracket): *(112 117)
UNIT
RATE ($) E M's CODE
B B B B B B
112 113 114 115 116 117
10m 8m 6m 5m 4 to 4.5m 3 to 3.5m * Strengthen existing lamp post in accordance with the method shown in drawing no. LP230302-003 (Case C) for ornamental lamp post planted on concrete pavement of the following height (with or without arm bracket): *(118 123)
No No No No No No
114.00 B B 112 113.00 B B 113 111.00 B B 114 110.00 B B 115 108.00 B B 116 106.00 B B 117
B B B B B B
118 119 120 121 122 123
10m 8m 6m 5m 4 to 4.5m 3 to 3.5m * Strengthen existing lamp post in accordance with the method shown in drawing no. LP230302-004 (Case D) for flange mounted lamp post on concrete pavement of the following height (with or without arm bracket): *(124 129)
No No No No No No
115.00 B B 118 114.00 B B 119 112.00 B B 120 111.00 B B 121 108.00 B B 122 106.00 B B 123
B B B
124 125 126
10m 8m 6m
No No No
70.00 B B 124 69.00 B B 125 67.00 B B 126
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 14
SECTION CODEB B B 127 128 129 5m 4 to 4.5 m 3 to 3.5m
DESCRIPTION
UNITNo No No
RATE ($) E M's CODE66.00 B B 127 64.00 B B 128 62.00 B B 129
* Salvage and strengthen upper section of existing lamp post in accordance with the method shown in drawing no. LP230302-005 (Case E) for lamp post planted on ground of the following height (with or without arm bracket): *(130 135) B B B B B B 130 131 132 133 134 135 10m 8m 6m 5m 4 to 4.5m 3 to 3.5m * Strengthen existing lamp post in accordance with the method shown in drawing no. LP230302-006 (Case F) for planted lamp post on uneven concrete pavement of the following height (with or without arm bracket): *(136 141) B B B B B B 136 137 138 139 140 141 10m 8m 6m 5m 4 to 4.5m 3 to 3.5m *Diamond Coring work to RC wall, column, beams, slab, brickwalls, etc *(142 148) B B B B B B B 142 143 144 145 146 147 148 50mm - 110mm diameter, 75mm - 175mm depth 50mm - 110mm diameter, 176mm - 275mm depth 125mm - 160mm diameter, 75mm - 175mm depth 125mm - 160mm diameter, 176mm - 275mm depth 175mm - 210mm diameter, 75mm- 175mm depth 175mm - 210mm diameter, 176mm- 275mm depth Mobilisation for coring works No No No No No No Per Job 33.00 B B 142/09 50.00 B B 143/09 57.00 B B 144/09 85.00 B B 145/09 86.00 B B 146/09 135.00 B B 147/09 300.00 B B 148/09 No No No No No No 116.00 B B 136 115.00 B B 137 113.00 B B 138 112.00 B B 139 110.00 B B 140 107.00 B B 141 No No No No No No 196.00 B B 130 177.00 B B 131 162.00 B B 132 158.00 B B 133 94.00 B B 134 90.00 B B 135
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 15
SECTION CODE
DESCRIPTIONBRICK/BLOCK WORKS (To be read in conjunction with Preambles) Brick/Hollow Block * Common Brickwall (size 215 x 102.5 x 65mm) laid in prepacked mortar with 10mm joints raked 10mm deep or flush pointed as work proceeds. *(001 004)
UNIT
RATE ($) E M's CODE
C C C
001 002 003
Generally One brick thick Half brick thick reinforced with expanded metal brickwork reinforcement at every 4th course. Half brick thick built in honeycomb 75mm thick BRICK-ON-EDGE reinforced with expanded metal brickwork reinforcement at every course with 10mm joints raked 10mm deep or flush pointed as work proceeds Half brick wall with facing bricks with expanded metal brickwork reinforcement at every 4th course laid in prepacked mortar with 10mm joints raked 10mm deep flush pointed in approved tinted cement mortar as work proceeds * Hollow block as specified in prepacked mortar flush pointed as work proceeds (reinforced with expanded metal brickwork reinforcement at alternate course) *(007 009)
m3 m2 m2
278.20 B C 1 62.00 B C 2 31.80 B C 3
C C
004 005
m2 m2
29.80 B C 4 23.70 B C 5
C
006
m2
61.20 B C 7
C C C C
007 008 009 010
75mm thick 100mm thick 150mm thick 100mm thick hollow block in prepacked mortar and reinforced expanded metal reinforcement in alternate course and blocks in each course filled in solid with Grade 20 concrete
m2 m2 m2 m2
17.00 B C 80 19.00 B C 8 29.50 B C 9 25.70 B C 10
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 16
SECTION CODE
DESCRIPTION* Common Modular Brickwall laid in prepacked mortar with 10mm joints raked 10mm deep or flush pointed as work proceed. *(011 013)
UNIT
RATE ($) E M's CODE
C
011
190mm thick using M211 modular brick size 190 x 90 mm x 90mm. 90mm thick using M211 modular bricks size 190 x 90mm x 90mm reinforced with expanded metal brickwork reinforcement at every four course. 90mm thick using M311 modular bricks size 290 x 90mm x 90mm reinforced with expanded metal brickwork reinforcement at every fourth course. Extra over common brickwork for forming exposed faces in selected common bricks, modular M211 & M311 including pointing in approved tinted cement mortar. (Applicable to 002 to 004, 011 to 013) Supply labour and materials to rake out mortar joints between standard bricks and repointing with prepacked mortar (based on area of brickwall) Supply labour and materials to rake out mortar joints between modular bricks and repointing with prepacked mortar (based on area of brickwall) * EXTRA OVER standard common bricks (size 215 x 102.5 x 65mm) for the following bricks : *(017 023)
m2
53.00 B C 11
C
012
m2
27.00 B C 12
C
013
m2
21.60 B C 13
C
014
m2
6.90 B C 14
C
015
m2
7.80 B C 15
C
016
m2
6.50 B C 16
C C C C C C C
017 018 019 020 021 022 023
Red facing bricks Overburnt facing bricks Brown facing bricks Pebble facing bricks Apricot facing bricks Desert facing bricks Grey facing bricks
m2 m2 m2 m2 m2 m2 m2
19.20 B C 17 30.00 B C 18 34.00 B C 19 34.00 B C 20 38.00 B C 21 34.00 B C 22 38.00 B C 23
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 17
SECTION CODE
DESCRIPTION* EXTRA OVER common modular bricks for using the following facing bricks to one face of the brickwall (applicable to brickwall of thickness 190mm and above) *(024 030)
UNIT
RATE ($) E M's CODE
C C C C C C C
024 025 026 027 028 029 030
Red facing brick Overburnt facing bricks Brown facing bricks Pebble facing bricks Apricot facing bircks Desert facing bricks Grey facing bricks * Extra over brick wall for the provision of HOT-DIPPED GLAVANISED STEEL WALL TIE SYSTEM fastened vertically to reinforced concrete surfaces including HOT-DIPPED GALVSNISED BONDING BAR SYSTEM at both end edges pf brick wall as shown in drawing no. EM-TC-STD-BLDG-0402-08 *(031 032)
m2 m2 m2 m2 m2 m2 m2
47.80 B C 24 55.70 B C 25 59.70 B C 26 67.70 B C 27 82.70 B C 28 67.70 B C 29 77.60 B C 30
C C
031 032
Brick wall cladding to rc wall Outer leaf of brick cavity wall cladding to rc wall Extra over half brickwall/solid block wall for the provision of HOT DIPPED GALVANISED BONDING BAR SYSTEM to the end edges of brick wall/solid block wall as shown in drawing no. EM-TC-STD-BLDG-0402-08 Glass Block Work
m2 m2
12.00 B C 31 12.20 B C 32
C
033
m
5.40 B C 33
C
034
180mm to 195mm square glass block of 80mm to 100mm thick laid in prepacked mortar and pointed with approved tinted cement mortar complete with panel reinforcing, panel anchors, expansion strips, etc. according to manufacturer's instructions
m2
270.60 B C 34
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 18
SECTION CODEC 035
DESCRIPTION"NEG" or other approved Glass block wall consists of 145 x 145 square glass block of 80 to 100mm thick glass laid in prepacked mortar and pointed with approved tinted cement mortar complete with panel reinforcing, panel anchors, expansion strips, etc. according to manufacturer's instructions Supply labour and material to rake out broken/damaged glass blocks of any size and replace with new glass block to match existing (for remedial work not exceeding 10 nos. glass blocks) Water Seepage Treament TREATMENT TO WATER SEEPAGE (SCAFFOLDING/GONDOLAS MEASURED SEPARATELY FOR WORKS ABOVE 6 METRE HEIGHT)
UNITm2
RATE ($) E M's CODE284.30 B C 35
C
036
No.
13.60 B C 36
C
037
Rake out joints to an even depth of 25mm to 30mm. Brush out all loose materials and fill the groove solid with approved polyurethane sealant/ polysulphide sealant in accordance with manufacturer's instruction to form a continuous sealant (Gondola measured separately). Extra over item for filling the groove/ expansion joint solid with an approved backing rod. Supply labour and materials to form splay with approved polymer modified cement mortor/non shrink grout to the correct gradient including hacking when necessary Apply 2 coats of clear elastometric waterproof membrane as specified including patching hairline cracks on brick wall with brick colour cement if necessary Apply 2 coats of clear elastometric waterproof membrane as specified including patching hairline cracks on brick wall if necessary
m
8.20 B C 37
C
038
m
1.40 B C 38
C
039
m
5.00 B C 39
C
040
m2
6.30 B C 43
C
041
m2
5.40 B C 44
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 19
SECTION CODEC 042
DESCRIPTIONRepair the patch joints between precast sills by mortar joint and approved polyurethane sealant according to manufacturer's instructions Apply approved polyurethane sealant to joints, pointing, grooves, cracks etc between frames, block walls, brick walls, rc walls, etc, according to manufacturer's instructions. Apply approved silicon sealant to joints, pointings, grooves, etc. according to manufacturer's instructions Repair to reinforced concrete beam cracks by hacking out existing crack and patch it with prepacked mortar gauged with approved synthetic latex or other approved additive including painting 2 coats of emulsion paint to the repaired surface Miscellaneous
UNITNo.
RATE ($) E M's CODE1.60 B C 45
C
043
m
4.10 B C 46
C
044
m
2.00 B C 47
C
045
m
6.20 B C 48
C
046
Labour and material for pointing joints of brickworks in coloured cement. Labour for raking out joints of existing brickwork, clean, re-jointing with cement mortar and re-pointing with a flush joint. Breaking up existing block or brickwork in cement mortar including plaster (measured gross thickness) and removing debris off site Cutting out existing block or brickwork to form chase etc not exceeding 300mm girth
m2
4.20 B C 49
C
047
m2
5.90 B C 50
C
048
m3
24.00 B C 51
C
049
m
7.30 B C 52
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 20
SECTION CODEC 050
DESCRIPTIONCutting out block or brickwork to form chase exceeding 300mm but not exceeding 600mm girth Cutting out block or brickwork to form opening Lay approved damp proof course well lapped at joints and bedded in prepacked mortar according to manufacturer's instructions Supply and lay approved horizontal damp proof course complied with BS 6398 Type B (felt fibre base) to brick/block walls bedded in prepacked mortar according to manufacturer's instructions Hack out cracks of brick or block walls to form `V' shaped grooves approximately 25mm wide x 20mm deep and seal up with polymer modified mortar and painting surfaces to match existing. Apply 2 coats of approved silane/siloxane based water penetrant according to manufacturer's instructions including patching hairline cracks on brick wall with brick colour cement if necessary Repair to cracks by hacking "U" groove on the cracks to 25mm width x 20mm depth. Brush out all loose sand and mortar and fill the groove with polymer modified mortar including painting to the repaired surface Repair to cracks by hacking V grooves on the cracks and patch with approved polysulphide sealant including painting to the repaired surface Supply labour and materials to repair the defective plaster by touching up defective concrete substrate with polymer modified mortar and skimming to average 6mm thick approved materials including hacking, applying bonding agent and painting and all as specified
UNITm
RATE ($) E M's CODE9.90 B C 53
C
051
m3
101.70 B C 54
C
052
m2
8.90 B C 55
C
053
m2
8.90 B C 56
C
054
m
4.00 B C 57
C
055
m2
6.60 B C 58
C
056
m
6.50 B C 59
C
057
m
19.40 B C 60
C
058
m2
26.40 B C 61
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 21
SECTION CODEC 059
DESCRIPTIONSupply labour and materials to repair the plastered wall panels by applying two coats of approved prepacked skim coat including hacking, painting to the repaired surface Supply labour and materials to repair defective plaster with average 18mm thick prepacked mortar including hacking, apply bonding agent and painting and all as specified Supply labour and materials to repair the defective plaster with average 18mm thick polymer modified mortar including hacking, apply bonding agent and painting and all as specified Installation of special wall tie to existing brickwall including galvanised mesh sleeve, approved resin, stainless steel wall tie Form nib with non shrink grout including Chemical Capsule @ 300mm centre to centre, necessary reinforcement, formwork, skimming coat and painting Form nib with Grade 30 concrete including Chemical Capsule @ 300mm centre to centre, necessary reinforcement, formwork, skimming coat and painting Watertightness test to external wall by spraying water at 300 litre/hour (Gondola measured separately) Watertightness test to external wall by spraying water at 600 litres/hour as specified (gondola measured separately and water provided by Town Council without charges) Watertightness test to external wall by spraying water at 300 litre/hour using perforated PVC pipe
UNITm2
RATE ($) E M's CODE13.50 B C 62
C
060
m2
20.70 B C 63
C
061
m2
44.10 B C 64
C
062
no.
8.10 B C 65
C
063
m3
3835.10 B C 66
C
064
m3
2812.60 B C 67
C
065
hr
9.70 B C 68
C
066
hr
10.50 B C 69
C
067
hr
7.50 B C 70
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 22
SECTION CODEC 068
DESCRIPTIONWatertightness test to external wall by spraying water at 600 litre/hour using perforated PVC pipe Hammer dressed random rubber in granite laid in prepacked mortar and pointed in coloured cement 13mm deep polyurethane sealant joint (horizontal or vertical) with 10mm diameter backer rod to fill gap between brickwall and beam/column as specified Supply and fix 100mm x 80mm x 6mm thick galvanised angle plate with approved 8mm diameter chemical adhesive galvanised stud archor @ 150 c/c to existing wall Supply labour and materials to rack out mortar joint at the interface to a depth of 25mm. Brush out all loose sand and mortar and fill the groove with polymer modified mortar Supply labour and materials to repair insitu-laid external tiles with G25 concrete screed and colour elastomeric membrane including hacking and all as specified Supply labour and materials to repair insitu-laid external tiles with approved prepacked skimming materials and colour elastomeric membrane including hacking and all as specified Supply labour and materials to rake out existing mortar joint, brush out all loose materials, fill the joint with approved backing rod, follow up with approved nonshrink grout in accordance with the manufacturer's instructins Strengthing of existing brickwalls, tile cladding, etc with 'Hilti' HRD wall tie including drilling holes, brush out all loose materials, fill hole with non-shrink grout and touch up hole with paint to match existing
UNIThr
RATE ($) E M's CODE8.20 B C 71
C
069
m3
222.70 B C 72
C
070
m
4.20 B C 73
C
071
m
50.80 B C 74
C
072
m
4.20 B C 75
C
073
m2
23.40 B C 76
C
074
m2
21.60 B C 77
C
075
m
7.60 B C 78
C
076
No.
7.70 B C 79
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 23
SECTION CODE
DESCRIPTIONPAVIOR (To be read in conjunction with Preamble) Cement and Sand Rendering * Prepacked screed rendering to ground floor trowelled to a smooth finish including coved and rounded angles: *(001 002)
UNIT
RATE ($) E M's CODE
D D
001 002
20mm thick For every 5mm thick over (or under) 20mm * 20mm thick prepacked screed to skirtings, treads, risers, curbs and return etc and trowelled to a smooth finish including coved and rounded angles for *(003 005)
m2 m2
8.80 B D 1 1.40 B D 2
D D
003 004
Not exceeding 150mm girth Exceeding 150mm but not exceeding 300mm girth Exceeding 300mm but not exceeding 450mm girth * Prepacked screed rendering to upper floor trowelled to a smooth finish including coved and rounded angles *(006 007)
m m
4.40 B D 3 6.90 B D 4
D
005
m
8.50 B D 5
D D
006 007
20mm thick For every 5mm thick exceeding 20mm thick up to a maximum of 60mm thick. * 20mm thick prepacked screed to skirtings, treads, risers, curbs and return etc and trowelled to a smooth including coved and rounded angles for *(008 010)
m2 m2
10.50 B D 6 1.75 B D 7
D D
008 009
Not exceeding 150mm girth Exceeding 150mm but not exceeding 300mm girth Exceeding 300mm but not exceeding 450mm girth
m m
4.60 B D 8 7.20 B D 9
D
010
m
8.90 B D 10
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 24
SECTION CODED 011
DESCRIPTIONExtra over for approved waterproofing compound incorporated in the cement paving for each 5mm thickness (applicable to other pavior items). Extra over for using hardener or other approved non-metallic hardener mixed according to manufacturer's instruction (applicable to other pavior items) Extra over 3mm thick coloured cement topping finish of terracotta, white, red and green colour, surface floated smooth with a steel trowel Granolithic Paving * Granolithic consisting of cement, sand and granite chipping (1:1:2) to floor trowelled to a smooth finish including pvc strip expansion joint where applicable *(014 015)
UNITm2
RATE ($) E M's CODE0.50 B D 11
D
012
m2
1.50 B D 12
D
013
m2
9.60 B D 13
D D
014 015
20mm thick For every 5mm thick exceeding 20mm thick up to a maximum of 60mm thick * 20mm thick Granolitic skirting, treads, risers, curbs and returns etc including coved and rounded angles for *(016 017).
m2 m2
9.70 B D 14 1.60 B D 15
D D
016 017
Not exceeding 150mm girth Exceeding 150mm but not exceeding 300mm girth 25mm thick Granolithic exposed aggregate paving consisting of cement, sand and granite chipping of (2:1:5) laid in panels with 12mm x 12mm deep recessed joints laterally at 1.2m centres
m m
4.90 B D 16 6.70 B D 17
D
018
m2
24.60 B D 18
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 25
SECTION CODE
DESCRIPTIONColoured Cement Paving
UNIT
RATE ($) E M's CODE
D
019
20mm thick single coloured cement paving to floor laid in panels on and including minimum 10mm thick prepacked base screed 20mm thick multi-coloured cement paving to floor laid in panels including minimum 10mm thick prepacked base screed Cast-in-situ terrazzo
m2
21.30 B D 19
D
020
m2
26.70 B D 20
D
021
20mm thick terrazzo finish to floor laid in sections, on and including prepacked base screed, polishing to approval * 20mm thick terrazzo skirtings, treads, risers, curbs and returns etc including coved and rounded angles polishing to approval *(022 023)
m2
43.70 B D 21
D D
022 023
Not exceeding 150mm girth Exceeding 150mm but not exceeding 300mm girth Mosaic Tiling * Semi-glazed mosaic tiles of approved colour and pattern to floor laid and jointed in cement grout on and including minimum 13mm thick prepacked base screed and pointed in neat cement *(024 026)
m m
9.00 B D 22 15.00 B D 23
D D
024 025
To floor Not exceeding 150mm girth to skirtings, treads, risers, curbs and returns etc with all necessary coved and rounded angles Exceeding 150 but not exceeding 300mm girth to skirtings, treads, risers, curbs and returns etc with all necessary coved and rounded angles
m2 m
50.40 B D 24 10.20 B D 25
D
026
m
18.20 B D 26
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 26
SECTION CODE
DESCRIPTION* Unglazed mosaic tiles of approved colour and pattern laid and jointed in cement grout on and including minimum 13mm thick prepacked base screed and pointed in cement. *(027 029)
UNIT
RATE ($) E M's CODE
D D
027 028
To floor Not exceeding 150mm girth to skirtings, treads, risers, curbs and returns etc. with all necessary coved and rounded angles Exceeding 150 but not exceeding 300mm girth to skirtings, treads, risers, curbs and returns etc with all necessary coved and rounded angles Brick Paving
m2 m
49.10 B D 27 9.40 B D 28
D
029
m
16.50 B D 29
D
030
Hack off existing damaged brick-on-edge on steps, coping, footpath Supply and lay new brick on edge in prepacked mortar to existing steps, coping, footpath, etc, including proper surface preparation pointing with cement mortar Brick-on-edge paving in facing brick laid to approved pattern and bedded on and including minimum 13mm thick prepacked mortar Brick-on-edge paving in single bull-nose one brick width laid and bedded on and including minimum 13mm thick prepacked mortar Brick on edge paving in double bullnose one brick width laid and bedded on and including 13mm thick prepacked mortar
m2
5.20 B D 30
D
031
m2
58.30 B D 31
D
032
m2
52.10 B D 32
D
033
m
16.50 B D 33
D
034
m
22.00 B D 34
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 27
SECTION CODED 035
DESCRIPTIONSupply and lay brick-on-edge at (minimum 60 dia inclination from ground level) single bull-nose brickwork in prepacked mortar with bedding and 10mm joints including excavation and levelling from site and levelling Brick tiles laid to approved pattern jointed, pointed and bedded on and including 13mm thick prepacked mortar Homogeneous/Ceramic Floor Tiling
UNITm
RATE ($) E M's CODE19.40 B D 35
D
036
m2
44.60 B D 36
D
037
Supply and lay any size, minimum 8mm thick heavy duty homogeneous polished floor tile of approved colour and pattern, jointed, pointed and bedded on and including minimum 20mm thick prepacked screed * Supply and lay to skirtings, treads, risers, curbs, nosings and returns, any size, minimum 8mm thick heavy duty homogeneous polished tile of approved colour and pattern, jointed, pointed and bedded on and including minimum 20mm prepacked base *(038 040)
m2
58.60 B D 37
D D
038 039
Not exceeding 150mm girth Exceeding 150mm but not exceeding 300mm girth Exceeding 300mm but not exceeding 450mm girth * Supply and lay any size, minimum 8mm thk heavy duty homogeneous polished floor tile of approved colour and pattern, jointed & pointed with approved grout *(041 044)
m m
11.30 B D 38 21.80 B D 39
D
040
m
33.20 B D 40
D D
041 042
Not exceeding 0.1m2 (for single patch) Exceeding 0.1m2 but not exceeding0.3m2 (for single patch) Exceeding 0.3m2 but not exceeding 0.5m2 (for single patch)
No. No.
6.90 B D 41 19.00 B D 42
D
043
No.
29.50 B D 43
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 28
SECTION CODED 044
DESCRIPTIONExceeding 0.5m2 but not exceeding 1m2 (for single patch) Supply and lay any size, minimum 8mm thick, heavy duty homogeneous unpolished floor tile of approved colour and pattern, jointed, pointed and bedded on and including minimum 20mm thick prepacked screed and pointing with approved tile, grouts as specified * Supply and lay to skirtings, treads, risers, curbs, nosings and returns, any size, minimum 8mm thick, heavy duty homogeneous unpolished tile of approved colour pattern, jointed, pointed and bedded on including minimum 20mm thick prepacked base screed *(046 048)
UNITNo.
RATE ($) E M's CODE59.00 B D 44
D
045
m2
39.00 B D 45
D D
046 047
Not exceeding 150mm girth Exceeding 150mm but not exceeding 300mm girth Exceeding 300mm but not exceeding 450mm girth * Supply and lay any size, minimum 8mm thk heavy duty homogeneous unpolished floor tiles of approved colour and pattern, jointed and pointed with approved grout (1:3) *(049 052)
m m
8.30 B D 46 14.20 B D 47
D
048
m
20.80 B D 48
D D
049 050
Not exceeding 0.1m2 (for single patch) Exceeding 0.1m2 but not exceeding 0.3m2 (for single patch) Exceeding 0.3m2 but not exceeding 0.5m2 (for single patch) Exceeding 0.5m2 but not exceeding 1.0m2 (for single patch). * Supply labour for laying ceramic tiles (any grade, size, colour and pattern) jointed and pointed with approved grout including minimum 20mm thick prepacked base screed *(053 056)
No. No.
6.50 B D 49 17.00 B D 50
D
051
No.
27.00 B D 51
D
052
No.
49.00 B D 52
D
053
To floor
m2
25.00 B D 53
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 29
SECTION CODED 054
DESCRIPTIONNot exceeding 150mm girth to skirting, treads riser, curbs, nosings and returns Exceeding 150mm but not exceeding 300mm girth to skirting, treads, riser, curbs, nosings and returns Exceeding 300mm but not exceeding 450mm girth to skirting, treads, riser, curbs, nosings and returns Nonslip nosing tile 200 x 60 x 8mm in steps or infront lift car entrance laid in approved colour, jointed and pointed and bedded on and including minimum 20mm thick prepacked base screed Slate Tiling * Supply and lay natural slate tiles in any approved colours and pattern jointed and pointed and bedded on and including minimum 20mm thick prepacked base screed *(058 062)
UNITm
RATE ($) E M's CODE6.50 B D 54
D
055
m
10.60 B D 55
D
056
m
17.10 B D 56
D
057
m
13.10 B D 57
D D D
058 059 060
10mm to 15mm thick 16mm to 20mm thick Not exceeding 150mm girth to skirtings, treads, risers, curbs, nosing and returns. Exceeding 150mm but not exceeding 300mm girth to skirtings, treads, risers, curbs, nosing and returns. Exceeding 300mm but not exceeding 450mm girth to skirtings, treads, risers, curbs, nosing and returns. Quarry / Klinker Tiling * Quarry / Klinker tiles of the following size laid and bedded on and including minimum 20mm thick prepacked base screed *(063 066)
m2 m2 m
37.70 B D 58 44.60 B D 59 6.50 B D 60
D
061
m
11.90 B D 61
D
062
m
19.60 B D 62
D D
063 064
100 x 100mm size 200 x 100mm size
m2 m2
34.10 B D 63 32.80 B D 64
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 30
SECTION CODED D 065 066
DESCRIPTIONAny size of 12 - 20mm thick Not exceeding 150mm girth to skirting, treads risers, curbs, nosing and returns. * Supply and lay quarry / klinker tiles of approved colour and pattern, jointed, pointed and bedded on and including minimum 20mm thick prepacked base screed *(067 070)
UNITm2 m
RATE ($) E M's CODE52.60 B D 65 4.80 B D 66
D D
067 068
Not exceeding 0.1m2 (for single patch) Exceeding 0.1m2 but not exceeding 0.3m2 (for single patch) Exceeding 0.3m2 but not exceeding 0.5m2 (for single patch) Exceeding 0.5m2 but not exceeding 1.0 m2 (for single patch) Teak Parquet Floor Tiling * Supply and lay teak parquet floor tile to match existing inclusive of approved adhesive and sanding down *(071 073)
No. No.
4.60 B D 67 13.10 B D 68
D
069
No.
18.90 B D 69
D
070
No.
37.90 B D 70
D D D D
071 072 073 074
10mm thick. 13mm thick 20mm thick Scrape off existing damaged parquet floor tile and remove all adhesive stains Interlocking Block Paving * Supply and lay interlocking concrete paving blocks (any colours and patterns) to footpath/concourse to match existing including compacting ground with additional sand bed to required level. *(075 076)
m2 m2 m2 m2
36.60 B D 71 42.10 B D 72 53.70 B D 73 5.10 B D 74
D D
075 076
60mm thick block 80mm thick block
m2 m2
29.60 B D 75 34.30 B D 76
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 31
SECTION CODE
DESCRIPTION* Supply and lay interlocking concrete paving blocks (any colours and patterns) to new footpath including compacting with 40mm thk (min) sand bed (Excavation and hardcore measured separately) *(077 079)
UNIT
RATE ($) E M's CODE
D D D
077 078 079
60mm thick 80mm thick 100mm thick *Supply and lay interlocking brick paving blocks to footpath/concourse compacting and laying additional sand-bed to required level *(080 081)
m2 m2 m2
26.80 B D 77 29.00 B D 78 31.40 B D 79
D D D
080 081 082
60mm thick 80mm thick Construct 100 x 200mm depth side kerb with grade 25 concrete including all necessary formwork Labour for taking out loosen sunken, interlocking concrete/brick paving block and relay paving blocks including compacting ground with additional hardcore and to required level and filling of voids Imprint Coating System
m2 m2 m
32.40 B D 80 34.30 B D 81 7.00 B D 82
D
083
m2
11.30 B D 83
D
084
Supply and lay "Superkote" or other approved high strength polymer coating imprint to floor according to manufacturer's instruction Supply and lay imprint surface in any colour to floor with 20mm thick cement and sand screed according to manufacturer's instruction Supply and lay 20mm thick concrete paving to floor imprint with recessed pattern, approved colour and varnish to match existing floor Supply and lay 50mm thick concrete stamping finish in patterns to floor according to manufacturer's instruction (concrete base measured separately) Pebble Wash Finishing
m2
20.50 B D 87
D
085
m2
37.00 B D 88
D
086
m2
35.00 B D 89
D
087
m2
40.00 B D 90
D
088
Supply and lay 15mm thick pebble wash/ coloured granolithic finish to floor, laid in section
m2
34.50 B D 91
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 32
SECTION CODED 089
DESCRIPTIONSupply and lay border 100 to 150mm girth with pebble washed/colour granolithic finish of 15mm thick Supply and lay border 150 to 300mm girth with pebble washed/colour granolithic finish of 15mm thick Extra over for every 5mm thick for Item 088 to 090 Concrete Topping * Grade 25 concrete screed with 10mm maximum size aggregate trowelled to smooth surface as specified. *(092 097)
UNITm
RATE ($) E M's CODE7.30 B D 92
D
090
m
12.30 B D 93
D
091
m2
8.30 B D 94
D D
092 093
25mm thick For every 5mm thick exceeding 20mm thick up to a maximum of 60mm thick Not exceeding 150mm in height/width Exceeding 150mm but not exceeding 300mm in height/width ADD to (or deduct from) Item 094 for each 5mm thickness over (or under) 25mm ADD to (or deduct from) Item 095 for each 5mm thickness over (or under) 25mm * Grade 40 structural concrete with 10mm maximum size aggregate topping including working around rod or fabric reinforcement (reinforcement measured separately) and trowelled to smooth surface with powerfloat as specified. *(098 099)
m2 m2
10.80 B D 95 1.60 B D 96
D D
094 095
m m
6.70 B D 97 9.60 B D 98
D
096
m
0.90 B D 99
D
097
m
1.25 B D 100
D D
098 099
25mm thick For every 5mm thick exceeding 25mm thick up to a maximum of 60mm thick Vinyl Tiling
m2 m2
15.40 B D 101 1.90 B D 102
D
100
Supply and lay 2mm thick vinyl floor tile to match existing inclusive of approved adhesive (Removal measured separately)
m2
18.30 B D 103
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 33
SECTION CODE
DESCRIPTIONSelf-levelling Screeding
UNIT
RATE ($) E M's CODE
D
101
Supply and lay self-levelling topping screed minimum 6mm thick (cementitious based) flooring with bonding agent and rubber strip expansion joint to fall with minimum 6mm thickness complete with one layer of sealer coat to manufacturer's instruction Supply and lay 3mm thick acrylic polymer cementitious coating system to manufacturer's instructions Add to Item 102 for one layer of sealer coat to manufacturer's instruction Supply and lay self-levelling screed top coat (system B) to corridor and staircase landing Dividing Strips
m2
16.10 B D 104
D
102
m2
15.20 B D 105
D
103
m2
2.75 B D 106
D
104
m
19.00 B D
D
105
Mosaic tiles to form court line (38mm to 50mm wide) for badminton, sepak takraw and basketball courts, etc. 25mm x 3mm aluminium dividing strips 25mm x 3mm copper dividing strips 25mm x 3mm stainless steel dividing strips PVC'L' shaped strips Epoxy Mortar Screeding
m
4.70 B D 107
D D D D
106 107 108 109
m m m m
6.90 B D 108 8.10 B D 109 9.70 B D 110 2.40 B D 111
D
110
Supply and apply epoxy mortar screed flooring system with epoxy resin primer follow by a layer of minimum 5mm thick epoxy mortar and a non-slip sealer coat after 24 hours curing Coloured Grout Finishing
m2
41.00 B D 112
D
111
Supply and lay one coat of finishing grout colour (sundek or other approved) to match existing complete with one coat of acrylic clear top coat for repair to colour screed surface Natural Stone Finishing
m2
16.30 B D 113
D
112
Supply and lay solnhofen natural stones of approved pattern, jointed, pointed and bedded on minimum 20mm thick prepacked base screed TACTILE TILE
m2
44.90 B D 114
D
113
Supply and lay "Tactile Tile" of approved design and colour, jointed, pointed and bedded on minimum 20mm thick prepared base screed
m2
96.40 B D
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 34
SECTION CODEMiscellaneous
DESCRIPTION
UNIT
RATE ($) E M's CODE
* Hack off all existing damaged rendering/finishings on floors, treads, risers etc and prepare surface to receive new finish *(114 116) D D D D 114 115 116 117 Not exceeding 25mm thick Exceeding 25mm but not exceeding 50mm thick Exceeding 50mm but not exceeding 75mm thick Hack existing floor to form random keys, clean and wash to receive new finish including removing debris from site Scrape off existing damaged vinyl tile/carpet/linoleum and remove all adhesive stains Apply one coat of approved bonding agent to receive new finishings according to manufacturer's instruction Supply and lay 20mm thick prepacked screed to receive floor finish Extra over floor screed for prepacked waterproof screed in lieu of prepacked screed to floor Patch up existing holes to floor rendering not exceeding 0.1 metre square in cement mortar (1:3) gauged with bonding agent top surface trowelled smooth to match existing. Patch up existing damaged mosaic floor finishings with new mosaic to match existing for single patch not exceeding 0.1 metre square Re-pointing joints of existing mosaic floor in white cement including cleaning floor on completion. Re-pointing joints of existing quarry tiles/ceramic tiles/brick paving with cement and fine sand. m2 m2 m2 m2 2.40 B D 115 3.40 B D 116 4.30 B D 117 1.30 B D 118
D
118
m2
1.80 B D 119
D
119
m2
0.80 B D 134
D
120
m2
6.30 B D 120
D
121
m2
3.10 B D 120
D
122
No.
2.10 B D 121
D
123
No.
6.70 B D 122
D
124
m2
4.60 B D 123
D
125
m2
3.80 B D 124
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 35
SECTION CODED 126
DESCRIPTIONTreatment to existing tiles/carpark ramp surface with anti-slip floor treatment chemicals according to manufacturer's instructions. Concrete base to tube stand of fixed table/stool in hawker centres not exceeding 200mm diameter and 75mm high including mosaic/ceramic tiles, coved tiles, to match existing Epoxy Sediment Colour Flakes Coating System to Wall or Floor
UNITm2
RATE ($) E M's CODE13.60 B D 125
D
127
No
15.00 B D 126
D
128
Supply and apply epoxy sediment colour flakes coating system with 2-component epoxy resin binder follow by a layer of sediment colour flakes and a non-slip 2component polyurethane binder. (Average thickness of coating shall be 1.2mm) Repair to Concrete Surface * Supply and lay approved two components patching compound mixed with liquid acrylic based additive according to manufacturer's instruction *(129 130)
m2
41.00 B D 127
D D
129 130
To floor of 4-5mm thickness To cracks in walls, slabs, soffits and floors approximately 25mm x 25mm deep including forming 'V' shaped grooves * Supply and lay approved single component consists of special cement and synthetic aggregates according to manufacturer's instruction *(131 132)
m2 m
16.30 B D 128 5.30 B D 129
D D
131 132
To floor of 4-5mm thickness To cracks in walls, slabs, soffits and floors approximately 25mm x 25mm deep including forming 'V' shaped grooves
m2 m
16.30 B D 130 5.30 B D 131
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 36
SECTION CODE
DESCRIPTION* Supply and lay approved two components mortar based compound consists of cement, additivies, aggregates and well-graded filler mixed with liquid acrylic polymer and synthetic resin according to manufacturer's instruction *(133 134)
UNIT
RATE ($) E M's CODE
D D
133 134
To floor of 4-5mm thickness To cracks in walls, slabs, soffits and floors approximately 25mm x 25mm deep including forming 'V' shaped grooves ROOFER (To be read in conjunction with preambles) Main Clay Roof and Accessory Tiles
m2 m
25.60 B D 132 6.60 B D 133
E
001
Supply only unglazed clay roof tiles in all colour to match existing Supply only semi-glazed clay roof tile in all colour to match existing Supply only glazed clay roof tile in all colour to match existing * Supply and lay unglazed clay roof main and accessory tiles in all colour to match existing *(004 008)
Piece
2.00 B E 1
E
002
Piece
2.70 B E 2
E
003
Piece
4.00 B E 3
E E E E E
004 005 006 007 008
Not exceeding 5 pieces Exceeding 5 pieces Ridge/hip tile Verge/End/Start Tile 3-way Apex tile * Supply and lay semi glazed clay roof main and accessory tiles in all colour to match existing *(009 013)
Piece m2 Piece Piece Piece
5.50 B E 4 45.00 B E 5 18.60 B E 6 13.20 B E 7 78.10 B E 8
E E
009 010
Not exceeding 5 pieces Exceeding 5 pieces
Piece m2
6.00 B E 9 51.20 B E 10
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 37
SECTION CODEE E E 011 012 013 Ridge/hip tile Verge/End/Start Tile 3-way Apex tile
DESCRIPTION
UNITPiece Piece Piece
RATE ($) E M's CODE22.20 B E 11 16.50 B E 12 82.50 B E 13
* Supply and lay glazed clay roof main and accessory tiles in all colour to match existing *(014 018) E E E E E E 014 015 016 017 018 019 Not exceeding 5 pieces Exceeding 5 pieces Ridge/hip tile Verge/End/Start Tile 3-way Apex tile Take up and relay interlocking roof tiles Corrugated Sheet E 020 Supply and lay asbestos-free corrugated roofing sheets (any profile) to match existing including galvanised screws (measured flat, no allowance made for laps) Supply and fix asbestos-free ridge fitting Repair corrugated (asbestos-free) roof sheets and relay same including supplying drive screws, washers, etc. Patch up nail holes in corrugated roofing sheets with mastic and one layer of bituminous felt. m2 24.00 B E 20 Piece m2 Piece Piece Piece m2 8.20 B E 14 61.00 B E 15 26.40 B E 16 20.30 B E 17 88.00 B E 18 7.20 B E 19
E
021
m
29.70 B E 21
E
022
m2
3.40 B E 22
E
023
No.
1.40 B E 23
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 38
SECTION CODEConcrete Panel E 024
DESCRIPTION
UNIT
RATE ($) E M's CODE
Lay over flat roof in 600 x 600 x 25mm thick panels in cement mortar 1:2 mixed with "sika" or other approved water-proofing compound as per manufacturer's instructions in the proportion of 2.3 kg of water-proofing compound to 45 kg of cement and 10mm joints subsequently filled with bitumen (Removal measured separately) Remove existing cement/sand panel roofing system to reinforced concrete flat roof including all necessary labour, plants and machineries for hoisting, transportation and disposal off site Apply a complete panel roofing system to roof surfaces comprising the following (i) a minimum of 20mm thick waterproofing cement and sand (1:3) base screed laid to fall; (ii) an approved waterproofing membrane complying with SS133:987 and its latest amendments; (iii) 50mm thick rigid extruded polystyrene foam (32 kg/m3) insulation board (iv) 38mm thick waterproofing cement and sand (1:3) panel trowelled to a smooth surface including all necessary labour and materials for bitumen infill at 900mm c/c contraction joints Secondary Slab
m2
18.00 B E 24
E
025
m2
7.90 B E 25
E
026
m2
43.50 B E 26
E
027
Removal of existing precast concrete secondary roof slabs including ferrocement roofing slabs and supports to reinforced concrete flat roof including all necessary labour, plants and machinery for hoisting, transportation and disposal of debris off site
m2
5.50 B E 27
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 39
SECTION CODE
DESCRIPTION* Supply and lay approved 50mm thick light weight precast concrete roof slab of any size to secondary roof including 10mm bitumen rebated or "V" grooved joint and removing existing damaged slab from site *(028 029)
UNIT
RATE ($) E M's CODE
E E E
028 029 030
Not exceeding 10 pieces per apartment block Exceeding 10 pieces per apartment block Supply and lay 600mm x 600mm x 30mm thick ferrocement secondary roof slabs, reinforced with galvanised welded fabric to reinforced concrete flat roof not exceeding 10 pieces per apartment block. (Removal measured separately) Supply and lay 600mm x 600mm x 30mm thick ferrocement secondary roof slabs, reinforced with galvanised welded fabric to reinforced concrete flat roof exceeding 10 pieces per apartment block (Removal of slabs measured separately) Supply and lay 600mm x 600mm x 30mm thick ferrocement secondary roof slabs, reinforced with galvanised welded fabric to reinforced concrete flat roof including all necessary solid supporting stools, 13mm x 13mm x 18SWG square galvanised wire mesh bent to shape, labour, plants, machineries and materials for jointing, hoisting, transportation and disposal off site Take out existing precast concrete secondary slabs including ferrocement coating slabs select from stack and relay slabs (New slabs measured separately)
m2 m2 No
36.40 B E 28 29.70 B E 29 11.40 B E 30
E
031
No
10.10 B E 31
E
032
m2
28.20 B E 32
E
033
m2
1.90 B E 33
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 40
SECTION CODEWaterproofing
DESCRIPTION
UNIT
RATE ($) E M's CODE
*Lay over the surface of concrete flat roof with cement and sand (1:3) screed gauged with approved waterproofing compound to falls *(034 035) E E 034 035 25mm thick For every 5mm thick exceeding 25mm thick up to a maximum of 50mm thick Supply and lay approved 1mm thick bitumen roofing felt as separation layer including bituminous paint for temporary treatment to address roof leak (Taking out existing and relay slabs measured separately) Supply and lay approved self adhesive waterproofing membrane 1.5mm thick for quick spot repair to defective roof membrane (Taking out existing and relay slabs measured separately) Remove existing waterproofing membrane system to reinforced concrete flat roof including all necessary labour, plants and machineries for hoisting, transportation and disposal off site. (Taking out existing and relay slabs measured separately) SOR item 039 to 042 are used for a complete "Flinkote Ultra" roof waterproof treatment system E 039 Supply and apply "Flinkote Ultra" or other approved Penetration Primer Supply and apply "Flinkote Ultra" or other approved waterproofing treatment 2 coats of application (Removal of existing waterproofing membrane measured separately) m2 0.65 B E 39 m2 m2 10.80 B E 34 1.45 B E 35
E
036
m2
7.60 B E 36
E
037
m2
10.40 B E 37
E
038
m2
2.00 B E 38
E
040
m2
5.70 B E 40
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 41
SECTION CODEE 041
DESCRIPTIONSupply and lay fibre glass (FG 4) or other approved with minimum 100mm lapping (Fibre glass membrane is laid between the 2 coats of Flinkote Ultra Waterproofing Treatment) Supply and apply "Flinkote Ultra" or other approved bituminous aluminium paint (finishing coat) Supply and apply 1 coat of "Newcoat" Primer S Supply and apply 1 coat of "Newcoat" water based acrylic polymer waterproofing membrane with integral micro fibre reinforcement (adhoc repair) (Removal of existing waterproofing membrane measured separately) SOR Item 045 is applicable for a complete "Newcoat" roof waterproofing system
UNITm2
RATE ($) E M's CODE2.10 B E 41
E
042
m2
0.85 B E 42
E E
043 044
m2 m2
0.55 B E 43 2.95 B E 44
E
045
Supply and apply 3 coats of "Newcoat" water based acrylic polymer waterproofing membrane with integral micro fibre reinforcement including 1 coat of Primer S (complete system) (Removal of existing waterproofing membrane measured separately) Polycarbonate Sheet * Supply and lay polycarbonate roofing sheet to linkway pavilion, etc including aluminium/steel frame *(046 048)
m2
8.20 B E 45
E E E
046 047 048
5mm thick 6mm thick 9mm Roof Insulation * Supply and fix wood wool slabs to underside of roof *(049 050)
m2 m2 m2
155.00 B E 46 183.00 B E 47 232.00 B E 48
E E E
049 050 051
25mm thick 50mm thick Supply and lay 50mm rigid extruded polystyrene foam insulation board of density minimum 32 kg/m3
m2 m2 m2
22.80 B E 49 33.20 B E 50 16.60 B E 51
ID: CY/wmy/BTW (OCT09)(26-10-2009)(Disk MAY/129A)
SOR Page 42
SECTION CODEE 052
DESCRIPTIONSupply and lay "Super Sisalation", "Super Brite" or other approved double-sided aluminium foil Supply and lay one layer of "Parsec Thermo Brite III" radient barrier to roof including lapping with thermosol-brite tape Expansion Joint
UNITm2
RATE ($) E M's CODE4.00 B E 52
E
053
m2
6.60 B E 53
E
054
Rake out bitumen or other compounds from existing expansion joints and refill same with `Polysulphide' expansion joint or other approved sealing compound including primer according to manufacturer's instruction Rake out bitumen from normal expansion joints and refill same with approval bitumastic compound including base packing. End Thrust
m
26.70 B E 54
E
055
m
4.30 B E 55
E
056
Construct hot dipped galvanised steel angle end thrust support for existing pipe end to reinforced con
Recommended