HEART SOUND RECORDER - Dr John Bennett

Preview:

Citation preview

HEART SOUND RECORDER

HSR SOFTWARE QUICK START1

HSR DESCRIPTION AND INTENDED USE1.HEARTSOUNDRECORDERDESCRIPTION&INTENDEDUSETheHeartSoundRecorder(HSR)isacomputerbasedLowRisk,GeneralWellnessHeartStressMonitortoacquire,display,recordandsaveheartsounds.

CertaintypesofheartstresscanbemonitoredbyvisualizingtheRate,RhythmandToneoftheheartcycle.Theheart’sreactiontocertaintypesofstress,suchaschemical,nutritionaloremotionalstress,canbenearlyimmediate,anditsresponsetoagivenmitigationtechniqueisoftenwithin5-10minutes.Thesechangescanbeobservedbychangesofthefrequency,ratio,amplitudeandcharacteristicsoftheheartwaveform.

IntendedUse:1. AHeartStressMonitorthatrecordsanddisplaysthelowfrequencycomponentoftheheartcycleasawaveformonaPC.2. Forthepurposeofvisualizingtherate,rhythmandtoneoftheheartcycle.3. Canbeusedtocomparecurrentandpreviousheartcyclewaveformsforbeforeandafteranalysis,orfortrendingpurposes.

IndicationsforUse:1. Usedtoenhanceandsupportahealthylifestylethroughstressmanagement.2. Usedtoreducetheriskorimpactofcertainchronicdiseasesorconditionswhereitiswellunderstoodandacceptedthathealthylifestylechoicesmayplayanimportantroleinhealthoutcomesforthediseaseorcondition.

3. Observetheeffectofchemicalornutritionalstressontheheart,suchasMSG,caffeine,orreUinedsugar.4. Canbeusedtoprovidevisualinformationontheeffectsofchemicalornutritionalinducedstressontheheart.

Claims: 1. May be used to promote or enhance heart function. 2. May be used to promote or improve dietary choices. 3. May be used to promote, improve or manage levels of stress. 4. May be used to promote physical and emotional wellbeing.

HSR SOFTWARE QUICK START2

THE CONTROL PANEL

HSR SOFTWARE QUICK START3

HSR SOFTWARE QUICK START

ENTERING A NEW CLIENTENTERING“NEWCLIENT”INFORMATIONA. [New]buttononTaskBarcreatesanewrecordinthedatabase

1. Bemindfulofcorrectspellingofnames2. DonotenterthesamepersonasaNewclientmorethanonce

B. ClientInformation1. FirstName,LastName,[Date/Time-stamp]a) ID-useforconUidentialityi.e.clientnumber+Date/Time-stamp

2. ClientInformation:DOB,Sex,Weight,BP,HR,SpO2%

C. SameNameProtocol:BUGWARNING1. ThesoftwareisunabletoaccommodatetwoclientswithidenticalUirstandlastnames.2. Ifyouencountertwoidenticalnames,a) AddatitleornumbertotheLastNameUield:SmithJr.orJones1orDoe2,etc.b)WARNING:SavingaduplicateFirstandLastnamewillresultinDataLossfortheUirstclient.SeeTroubleshooting.

c) AlwaysuseReturningClient[NewSession]forasecondsession.EnteringthesameclientasNewwillresultinDataLoss.SeeTroubleshooting.

D. SessionNotes:1. Example:supplementsrecommended;caffeineorrecentmealpriortosession;prescriptiondrugstaken,etc.DifUicultyacquiringarecording

4

ENTERING A RETURNING CLIENTENTERINGa“RETURNINGCLIENT”SESSION(alltheClientrecordsarehere)

A.Select[ClientList]buttononTaskBar1. TypeLASTnametosearch2. SelecttheClient’sname>select[NewSession]3. Toreviewaprevioussession>[Select]4. Bemindfulnottoenterapersonundermisspelledortransposednames

HSR SOFTWARE QUICK START5

CONTROL UNIT FRONT PANEL

HSR SOFTWARE QUICK START6

RECORDING A HEART GRAPHA.ApplytheMicrophoneaccordingtothetechniquestaughtintheTrainingSessionsB.SelectthebuttonfromtheValveTaskBartoindicatethevalvebeingrecorded

1. Select[Start]tobegintherecordingfunction.C.GraphDisplayWindowopenstodisplaytheclient’sheartcycle.

1.TUNE:AdjusttheVolume/SensitivityknobontheControlUnitaccordingtothetrainingreceivedintheTrainingSessions

2. [Record]buttonbeginsa15secondrecordinga)Attheendofthe15sec.recording,thesoftwarereturnstotheControlPanelwiththerecordedvalve’sGraphDisplaycontainingthegraphjustcompleted

3. Start/Stopa) Afunctiontostartorstopthelivegraph.b) Toclosethewindow,Uirst[Stop]thelivegraph,thenclose

D.Recordingoptionsforrecordingagraph1. Selectthe[RECORD]buttononbottomofdisplaywithamouseorPCtouchpad2.PresstheRhythmLightSwitchonControlUnit

a) WhenyouTunebyadjustingtheVolume/Sensitivityknob,youcaninstantlyrecordbypressingtheUlashinglightswitchwithyourthumb

b) TheUlashingRhythmLightisavisualindicatorofwhenyouarenearlyintunei.e.ifyoudonotobservetherepeatingbeatofS1&S2(lubdub....lubdub),youneedtoadjust–eitherwithmicrophoneplacement,orwithvolume/sensitivity

HSR SOFTWARE QUICK START 7

THE GRAPH DISPLAY WINDOWONCETHERECORDINGISACQUIRED

A.ManipulatecalipersinDisplayWindow1.LowerCaliper:Scrollthrough15secofrecordingtoselectheartcyclesyouwishtodisplayforeachvalve

2.UpperCaliper:OnlywithMitralvalveselected,measuretheheartrateoftheheartcyclefromcommonpointsontwoadjacentS1beatsa)DisplaysunderHeartlogo:Measuredheatrate:67Bpm@MitralValve.

3.UpperCaliper:Allvalves–measureseventwidthasduration(time)ofS1orS2,restperiods,work/restratios,etc.Canbeusedforcomparison.a)MeasuredTimedisplaysas0.00secondsaboveDisplayWindow

B. [Save]function1. Thesoftwarehaswarningsifyouaccidentallyomitavalveorclosebeforesaving,2. Asessioncanbereopenedtoaddnotes,repositionthecalipers,etc.TheSaveWarningwindowwillquestionyourmotives.

HSR SOFTWARE QUICK START8

THE DISPLAY CALIPERS

HSR SOFTWARE QUICK START9

VIEW COMPLETE RECORDINGVIEWTHECOMPLETERECORDING

1. TheFullDisplay[FullDisp]buttonintheTaskBaropensanewwindowthatcontainsthefullrecordingofthefourvalves.

2. Clickthe[Valve]buttonsatthetoptotogglethroughthefourvalverecordingsR3. Theuserisunabletosave,printorcreateapdffromthisscreen.4. Tosavethisgraph,useWindowsSnipittoolandsaveitasajpegUile.

HSR SOFTWARE QUICK START10

PRINT PREVIEW WINDOW

HSR SOFTWARE QUICK START11

COMPARE SESSIONSCOMPARESESSIONS

A.Select[Compare]buttontocomparetwodifferentsessionsforthesameclient.1. SelectClient>Selecttwosessionstocompare2. Comparewindow>selectvalvetocompare3.Manipulateupperandlowercalipersofeachsession4. PrintorCreatePDF

HSR SOFTWARE QUICK START12

HEART-SOUND RESEARCH LLC

HSR SOFTWARE QUICK START

Technical Support heartsoundresearch@gmail.com

970-402-9860

13