12

invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site

  • Upload
    lethuy

  • View
    239

  • Download
    0

Embed Size (px)

Citation preview

Page 1: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 2: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 3: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 4: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 5: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 6: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 7: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 8: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 9: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site
Page 10: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site

FOR ROUGH BIDDING ONLY

MOJA

VE V

5

AIR

STAR

40CO

MPRE

SSOR

Proma PromaProma

Proma

Proma

Proma

Proma

CONSULT.

OFFICE

ADARESTROOM

ADARESTROOM

PRIVATEOFFICE

LAB

STERILIZATION

DR #1

DR #2

DR #3

DR #4

DR #5 HYG #1 HYG #2

I-CATCBCTX-RAY

WORKSTATION

DENTALMECHANICALSTAFF

LOUNGE

CYL.STORAGEOFFICE

MECHANICAL

3R7C

3

7C

3

7C

3

3

3

3

3

7C

7C

7C

7C

111316

17

111330G

15

15B25

27B

3030E

29A

33

NOTE: HENRY SCHEIN WILL SUPPLY ALLDENTAL TEMPLATES ON JOB SITE.

NOTE: HENRY SCHEIN WILL SUPPLY ALLDENTAL TEMPLATES ON JOB SITE.

1

1

3R3R

3R

3R

3R

3R

THIS PLAN IS FOR THE SOLE PURPOSE OF SPECIFICATION ANDINSTALLATION OF THE DENTAL EQUIPMENT SUPPLIED BY HENRYSCHEIN DENTAL. THE SPACE PLANNING AND CONCEPTUALDESIGN HAS BEEN PROVIDED BY OTHERS.

PLEASE NOTE: CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL REQUIREDUTILITIES. ALL REQUIREMENTS TO BE VERIFIED BY MANUFACTURER'S SPEC SHEETSPROVIDED BY HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. MANUFACTURER'SSPECS SUPERSEDE ANY AND ALL INFORMATION CONTAINED HEREIN.

PLUMBING SPECIFICATIONS

QUA

NTIT

Y

SPEC

. NUM

BER

DESCRIPTION CO

LD W

ATE

RHO

T W

ATE

RD

RAIN

CO

MPR

ESSE

D A

IRN

ATU

RAL

GA

SV

AC

UUM

N20

OXY

GEN

VEN

T

UTILITIES

MEC

H. D

ETA

IL

CO

NS.

DET

AIL

77

7

2

21

1

1

1

1

1

1

1

1

1

1

33R

7C

11

1315

15B

16

17

25

27B

29A

30

30E

30G

33

UTILITY CENTER (TOE OF CHAIR) - BACK FLOW PREVENTION REQUIRED AS PER LOCAL CODE.UTILITY CENTER (REAR CABINET) - BACK FLOW PREVENTION REQUIRED AS PER LOCAL CODE.N2O-O2 SYSTEM WITH D.I.S.S. TERMINATIONS - CONTRACTOR (MED GAS CERTIFIED WHEREREQUIRED BY CODE) TO PROVIDE REQ'D UTILITIES. SILVER SOLDERED TYPE K OR L COPPER LINES,3/8" OD NITROUS AND 1/2" OD OXYGEN COMING FROM THE SYSTEM MANIFOLD, TERMINATEWITH D.I.S.S. FITTINGS AT FINISHED FLOOR OR WALL. SEE UTILITY CENTER DETAIL FOR VACUUMLOCATION. PLUMBER TO REQUEST VALVES FROM HENRY SCHEIN REP FOR INSTALLATION.FOLLOW NFPA CODES.MODULAR SINKS & FAUCETS - SINK AND FAUCET SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLEDBY CONTRACTOR. FINAL CONNECTIONS BY CONTRACTOR.COMPRESSED AIR LINE AND VALVE - TERMINATE WITH A 1/2" SWEAT X 3/8" COMPRESSION STOP.ULTRASONIC CLEANER - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL.HANDPIECE MAINTENANCE SYSTEM - CONTRACTOR TO PROVIDE REQ'D UTILITIES. 1/2" AIR LINEWITH VALVE STOP (58-145 PSI) ABOVE COUNTERTOP. SYSTEM SUPPLIED AND INSTALLED BYHENRY SCHEIN DENTAL.MODEL TRIMMER - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BACK FLOWPREVENTION AS REQUIRED PER CODE.PLASTER TRAP - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY CONTRACTOR ON SINKDRAIN LINE.DENTAL AIR COMPRESSOR - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY CONTRACTOR.FOR GAS-DRIVEN DEVICES IN A LEVEL 3 FACILITY. 1/2" I.D. COPPER TYPE K OR L SUPPLY LINESTO LOCATIONS THAT REQUIRE AIR. BUCK BOOST TRANSFORMER SUPPLIED AND INSTALLED BYCONTRACTOR (IF REQ'D). FINAL CONNECTIONS BY CONTRACTOR. REFER TO NFPA 99, 2005,5.3.3.5 FOR REGULATIONS & REQUIREMENTS.VACUUM PUMP (DRY) - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY CONTRACTOR. 1.5"OR 2" MAIN TRUNK LINES. USE SCH 40 PVC WHERE PERMITTED BY CODE. VERIFY TRUNK &BRANCH LINE SIZES WITH MFR RECOMMENDATIONS. EXHAUST PUMP TO OUTSIDE. BACK FLOWPREVENTION REQ'D PER LOCAL CODE. BUCK BOOST TRANSFORMER SUPPLIED AND INSTALLEDBY CONTRACTOR (IF REQ’D). FINAL CONNECTIONS BY CONTRACTOR. PROVIDE WATER LINEWITH HOSE BIB NEAR UNIT.AMALGAM SEPARATOR - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY PLUMBER. VERIFYLOCATION WITH HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.REMOTE WATER CONTROL VALVE - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BYCONTRACTOR ON COLD WATER SUPPLY LINE.DENTAL WATER LINE TREATMENT SYSTEM (P&C VISTACLEAR) - SUPPLIED BY HENRY SCHEINDENTAL, INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE 1/4" COPPER LINE TO EACHTREATMENT ROOM AT LOCATIONS REQUIRING WATER. IF RUN SUB-FLOOR, HOUSE IN 1" I.D. SCH40 PVC.ULTRA PURE WATER SYSTEM (P&C VISTAPURE @ STERILIZATION) - SUPPLIED AND INSTALLED BYHENRY SCHEIN DENTAL.N2O-O2 SYSTEM MANIFOLD - MANIFOLD SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BYCONTRACTOR. CONTRACTOR TO RUN SILVER SOLDERED K OR L COPPER TRUNK LINESRUNNING TO EACH (7) AND/OR (7C) LOCATION. PRESSURE TEST LINES SEPARATELY WITH DRYNITROGEN AT 150 PSI FOR 24 HOURS. FOLLOW NFPA CODES.

●●

● ●

●●

●●

33R

7C

1315

15B

16

16

25

27B

29A

30

30E

30G

33

PROPOSED PLUMBING PLAN1/4"=1'-0"

PLUMBING NOTES

5. WATER PRESSURE MUST NOT EXCEED 50 PS1 AT ALL DENTAL UNITS.

6. BACK-FLOW PREVENTION IS REQUIRED ON ALL LINES AS PER LOCALCODE.

3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTSFOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULTWITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION.

1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THEPLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FORCONSTRUCTION.

2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THEHENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.

SEE SHEETS SPE.1 & SPE.2 FOR SPECIFICATION DETAILS

4. ANY REFERENCE TO "AIR", "COMPRESSED AIR" OR "AIR COMPRESSOR"REFER TO THE UNIT AND ALL COMPONENTS WHICH ARE CONSIDERED ALEVEL 3 DENTAL AIR SUPPLY SYSTEM.  REFER TO NFPA 99, 2015, 5.3.3.6FOR REGULATIONS & REQUIREMENTS. THIS SHOULD NOT BE CONFUSEDWITH "AIR" AS IT IS DEFINED IN LEVEL 1 OR LEVEL 2 MEDICAL FACILITIES.

TEE FITTING

MAIN LINE

45 ELBOWS

BRANCH LINE CONFIGURATIONSUB FLOOR

THE VACUUM PIPING LAYOUT HAS A LARGE EFFECT ON THE EFFICIENCYAND RELIABILITY OF THE DENTAL VACUUM SYSTEM. REFER TOMANUFACTURER'S PRE-INSTALLATION GUIDE PROVIDED BY HENRYSCHEIN EQUIPMENT SPECIALIST (FOR SPECIFIC SIZING OF STUB-UP, TRUNK,AND BRANCH LINES.

IT IS HIGHLY RECOMMENDED THAT VACUUM LINES RUN UNDERNEATHDENTAL EQUIPMENT BY MEANS OF TRENCHING/ CORING (CONCRETESLAB) OR IN SUB FLOOR (BASEMENT/ CRAWL SPACE). ALL LINES ARE TOBE DESIGNED WITH PVC PIPING UNLESS DICTATED BY LOCAL CODES TOUSE COPPER OR CAST IRON.

TO ENSURE OPTIMUM VACUUM PERFORMANCE, INSTALL MAIN LINEDIRECTLY BELOW THE DENTAL CHAIR, CABINET OR WALL JUNCTION BOXTO REDUCE OR ELIMINATE BRANCH LINE RUNS WHEREVER POSSIBLE.

I. STUB-UPTERMINATE VACUUM TRUNK LINE IN MECHANICAL ROOM. PLUMBINGCONTRACTOR TO PROVIDE FPT ADAPTOR ON END OF STUB-OUT FROMFLOOR OR WALL. SIZE OF ADAPTOR TO BE DETERMINED BY TRUNK ANDPUMP INTAKE PIPE SIZES. SEE DETAILS THIS SET & MANUFACTURERTEMPLATES PROVIDED BY HENRY SCHEIN EQUIPMENT REP. IN THE CASEOF DUAL TRUNK LINE SYSTEM, PROVIDE ENOUGH SPACE BETWEENSTUB-UPS TO INSTALL TEES ON BOTH LINES.

2. TRUNK LINE(S)VACUUM TRUNK LINES(S) TO BE SUPPORTED EVERY 6'-0" TO PREVENT SAGAND SLOPED A MINIMUM OF 1/4" PER 10'-0" TOWARD THE VACUUMPUMP.

3. BRANCH LINE(S)BRANCH LINES ARE TO HAVE "SWEEPING" 90 DEGREE TURNS TO AVOIDVACUUM LOSS. A "WYE" FITTING SHOULD BE USED TO JOIN BRANCHLINES TO THE TRUNK LINE.

SPECIAL NOTE:IF VACUUM LINES ENCROACH ON EITHER A WALL OR COLUMN FOOTING, USE 45DEGREE ELBOWS TO PIPE AROUND FOOTING SO PIPE REACHES PROPERLOCATION.

DO NOT PIPE TRUNK LINE IN A SERIESMANNER LOOPING FROM J-BOX TOJ-BOX. A CONTINUOUS TRUNK LINEMUST BE MAINTAINED FROM THE PUMPTO THE FURTHEST J-BOX USING BRANCHLINES OFF OF THE TRUNK LINE TO PICKUP EACH VACUUM OUTLET. TRUNK LINEMAY FOLLOW DRAIN LINE TRENCHESWITHIN REASON. USE ONLY 45 EL'S. DONOT USE ANY 90 EL'S. ALL SUB FLOORSCH 40 PVC CONNECTIONS ARE TO BEPLUMBED WITH 45 EL'S USING DETAIL AFOR TEEING BRANCH LINECONNECTIONS INTO TRUNK LINE.

DETAIL AWYE FITTING (USE FOR ALL SUB

FLOOR INTERSECTIONS)

VACUUM NOTES

SEE HENRY SCHEIN REP FOR MANUFACTURER'S RECOMMENDED VACUUM LINE LAYOUT

SP.1

24 x 361/4"=1'-0"DENTAL PLUMBING

PLAN

THIS

DO

CUM

ENT

HAS

BEEN

PRE

PARE

D A

S A

N IN

STRU

MEN

T O

FPR

OFE

SSIO

NA

L SE

RVIC

E. I

T IS

NO

T AN

ARC

HITE

CTU

RAL

PLA

NA

ND

IS N

OT I

NTE

NDE

D FO

R C

ON

STRU

CTIO

N.

THE

IDEA

S/D

ESIG

N IN

CLU

DED

HER

EIN

ARE

THE

SO

LE P

ROPE

RTY

OF

HEN

RYSC

HEIN

DEN

TAL

AN

D A

RE P

ROTE

CTE

D U

ND

ER C

OPY

RIG

HT.

THES

E PL

AN

S M

AY

NO

T BE

USE

D O

R RE

PRO

DUC

ED W

ITHO

UTEX

PRES

SED

WRI

TTEN

CO

NSE

NT

OF

HEN

RY S

CHE

IN A

ND

FUL

LPA

YMEN

T O

F A

NY

ASS

OC

IATE

D D

ESIG

N F

EES.

ALL

DIM

ENSI

ON

S A

RE S

UBJE

CT T

O J

OB-

SITE

VER

IFIC

ATIO

N.

REVISIONS:

HENRY SCHEIN REP:

PRO

JEC

T:

LOC

ATIO

N:

SCALE: SHT. SIZE:INT.SQ.FT.=

2017 by HENRY SCHEIN, INC.c

CENTER:

PHONE #:

DRAWING NAME:

PROJECT START DATE:

FINALS START DATE:

DRAWN BY:FINALS BY:CHECKED BY:

1092

0 W

LIN

CO

LN A

VE,

WES

T A

LLIS

, WI

5322

7

HEN

RYSC

HEI

NR

DR

. S

AM

ER

OB

EID

ROC

HEST

ER H

ILLS

MIC

HIG

AN

FRANK WISNEWSKI

DETROIT, MI

(248) 755-0149

OBEID-1-F

08/11/2017

08/11/2017

ARCHTLTLBZ

--/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- ---

PER ARCH

7. REFER TO ARCHITECT'S DRAWINGS FOR PLUMBING REQUIREMENTS INALL AREAS NOT INDICATED ON THIS PLAN.

KEYED NOTESHENRY SCHEIN TO SUPPLY MCC CABINETS IN LAB-STERILIZATIONAREA. CONTRACTOR TO PROVIDE ALL COUNTER TOPS WITH FULLHEIGHT BACKSPLASH. HENRY SCHEIN TO PROVIDE ALL PLUMBINGFIXTURES AND TASK LIGHTING.

1

AutoCAD SHX Text
FLOW
AutoCAD SHX Text
PUMP
AutoCAD SHX Text
TO
AutoCAD SHX Text
FLOW
Page 11: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site

FOR ROUGH BIDDING ONLY

D-13AIR AT STERILIZATION AND LABNOT TO SCALE

SPE.1D-13-1

AIR VALVE W/ TUBING TO BE PLACEDAT SAME HEIGHT AS WATER VALVES

HOT WATER VALVECOLD WATER VALVE

2x4 PLASTIC ELECTRICAL BOX

D-13-1AIR VALVENOT TO SCALE

AIR LINE BY CONTRACTOR

3/8" COMPRESSION FITTINGOR OPTIONAL FEMALE QUICKDISCONNECT PROVIDED &INSTALLED BY CONTRACTOR.

FITTINGS PROVIDED ANDINSTALLED BY CONTRACTOR.

SEE ACTUAL VALVE TOADJUST THE MOUNTINGPOSITION OF THE 1/2" FPTADAPTOR SO THE TRIM RING ISSECURED FIRMLY AGAINST THESHEETROCK.

ANCHOR TERMINATIONFITTINGS SECURELY TO A STUDOR A CROSS BRACE.

AIR VALVE PROVIDED ANDINSTALLED BY CONTRACTOR.

1/2" FEMALE ADAPTORPROVIDED & INSTALLED BYCONTRACTOR.

ELECTRICAL WHIP

D-3RDENTAL UNIT WALL UTILITY CENTERNOT TO SCALE

GENERAL NOTES:-THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. DENTAL DEALER WILL PROVIDE INSTALLATION TEMPLATES FOR ANYEQUIPMENT IN QUESTION. REFER TO MANUFACTURER'S INSTALLATION GUIDE/TEMPLATE FOR ADDITIONAL INFORMATION.

-LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL ALL UTILITIES.

-ALL UTILITIES MUST CONFORM WITH PREVAILING LOCAL CODES. NEITHER DENTAL DEALER NOR MANUFACTURER CAN BE HELDRESPONSIBLE FOR AN INSTALLATION WHICH DOES NOT MEET LOCAL ELECTRICAL AND PLUMBING CODES.

ELECTRICAL: ELECTRICAL CONTRACTOR TO PROVIDEELECTRICAL WHIP FOR HARD WIRED CABINET

FRONT VIEW

WATER: PLUMBING CONTRACTOR TO PROVIDE ANDINSTALL A 1/4" SOFT COPPER WATER SUPPLY LINE FROMVISTACLEAR SYSTEM TO THIS LOCATION. WHEN SUB-FLOOR, LINE SHOULD BE RUN WITHIN A 1" PVCCONDUIT. STUB-UP 1-2" FROM FLOOR AND TERMINATEWITH A 1/4" x 1/4" COMPRESSION NEEDLE VALVE. FLUSHSYSTEM CLEAN PRIOR TO EQUIPMENT INSTALLATION.

FLOOR

SHEETROCK

ELECTRICAL WHIP

VACUUM

WATER

AIR

AIR

TOP VIEW

CENTRAL VACUUM: PLUMBING CONTRACTOR TOPROVIDE A BRANCH LINE TO LOCATION SHOWN (SIZEPER CENTRAL VACUUM SUPPLIER). REDUCE TO A 1/2"SCH. 40 PVC RISER AT WALL. TERMINATE 1-2" FROMWALL FOR CONNECTION TO EQUIPMENT.

COMPRESSED AIR: PLUMBING CONTRACTOR TOPROVIDE AND INSTALL A 1/2" COPPER (OR ACCEPTED)SUPPLY LINE FROM AIR COMPRESSOR TO THIS LOCATION.STUB-UP 1-2" FROM FLOOR AND TERMINATE WITH A 90°1/2" x 3/8" COMPRESSION SHUT-OFF VALVE. FLUSHSYSTEM CLEAN PRIOR TO EQUIPMENT INSTALLATION.

CHASE TO CEILING

2 GANG MUD RING

CHASE TO CHAIR

VACUUMWATER

CHASECHASE: ELECTRICAL CONTRACTOR TO PROVIDE A GRAYELECTRICAL PVC PIPE CHASE WITH PULL-STRINGSUB-FLOOR (SEE SPECS 4, 4A SHEET SE.1 FOR SIZE ANDLOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB-UPFLUSH WITH SUB-FLOOR, MARK LOCATION OF PIPE ATFINISH.

AIR

WATER

CHASE

ELEC.

VAC.

D-3TYPICAL UTILITY CENTERNOT TO SCALE

GENERAL NOTES:-THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. DENTAL DEALER WILL PROVIDE INSTALLATION TEMPLATES FOR ANYEQUIPMENT IN QUESTION. REFER TO MANUFACTURER'S INSTALLATION GUIDE/TEMPLATE FOR ADDITIONAL INFORMATION.

-LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL ALL UTILITIES.

-ALL UTILITIES MUST CONFORM WITH PREVAILING LOCAL CODES. NEITHER DENTAL DEALER NOR MANUFACTURER CAN BE HELDRESPONSIBLE FOR AN INSTALLATION WHICH DOES NOT MEET LOCAL ELECTRICAL AND PLUMBING CODES.

ELECTRICAL: ELECTRICAL CONTRACTOR TO PROVIDEAND INSTALL A 1/2" CONDUIT AND BOX WITH 115VQUAD (OR EQUAL) RECEPTACLE. WIRE BOX PER CODEWITH TOP NO HIGHER THAN 4-1/2" A.F.F.

TOP VIEW

SECTION AT FLOOR

WATER: PLUMBING CONTRACTOR TO PROVIDE ANDINSTALL A 1/4" SOFT COPPER WATER SUPPLY LINE FROMVISTACLEAR SYSTEM TO THIS LOCATION. WHEN SUB-FLOOR, LINE SHOULD BE RUN WITHIN A 1" PVC CONDUIT.STUB-UP 1-2" FROM FLOOR AND TERMINATE WITH A 1/4" x1/4" COMPRESSION NEEDLE VALVE. FLUSH SYSTEM CLEANPRIOR TO EQUIPMENT INSTALLATION. IF USING ABOWL-TYPE CUSPIDOR, A SEPARATE STANDARD WATERLINE MUST ALSO BE PROVIDED. CONSULT WITH HENRYSCHEIN REP.

CENTRAL VACUUM: PLUMBING CONTRACTOR TOPROVIDE A BRANCH LINE TO LOCATION SHOWN (SIZEPER CENTRAL VACUUM SUPPLIER). REDUCE TO A 1/2"SCH. 40 PVC (OR COPPER) RISER AT FLOOR. TERMINATE1-2" ABOVE FINISHED FLOOR FOR CONNECTION TOEQUIPMENT.

CHASE: ELECTRICAL CONTRACTOR TO PROVIDE AGRAY ELECTRICAL PVC PIPE CHASE WITH PULL-STRINGSUB-FLOOR (SEE SPECS 4, 4A SHEET SE.1 FOR SIZE ANDLOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB-UPFLUSH WITH SUB-FLOOR, MARK LOCATION OF PIPE ATFINISH.

COMPRESSED AIR: PLUMBING CONTRACTOR TOPROVIDE AND INSTALL A 1/2" COPPER (OR ACCEPTED)SUPPLY LINE FROM AIR COMPRESSOR TO THIS LOCATION.STUB-UP 1-2" FROM FLOOR AND TERMINATE WITH A 90°1/2" x 3/8" COMPRESSION SHUT-OFF VALVE. FLUSHSYSTEM CLEAN PRIOR TO EQUIPMENT INSTALLATION.

THIS SYSTEM MEETS NFPA 99STANDARDS FOR DENTAL GASSYSTEMS. LOCAL CODES MAYSUPERSEDE NFPA 99. VERIFY LOCALREQUIREMENTS BEFORE INSTALLATION.

D-7CN2O SYSTEM TERMINATIONSNOT TO SCALE

TUBING TO H.V.E.

VACUUM LINE

3/8"

N2 O

CO

PPER

LIN

E FR

OM

MA

NIF

OLD

1/2"

O2 C

OPP

ER L

INE

FRO

MM

AN

IFO

LD

SEE UTILITY CENTER DETAIL(S) FORLOCATION OF RISERS WITHINCABINET.

TUBING TO CABINETMOUNTED N2O VACUUMSWITCH OR OUTLET

5/8" O.D. COPPER TEE (VERIFYSIZE WITH EQUIPMENT REP)

SHUT OFF VALVES (OR CHECK VALVESDEPENDING ON MFR.) PROVIDED BYHENRY SCHEIN DENTAL, INSTALLED BYPLUMBER (MED GAS CERTIFIED WHEREREQUIRED BY CODE).

THIS DETAIL IS FOR INFORMATIONALPURPOSES ONLY. SEE SYSTEMMANIFOLD DETAIL (33) ANDMANUFACTURER'S INSTALLATIONGUIDE FOR MORE INFORMATION.

N2O

O2

FLOOR

WALL

D-9BNOT TO SCALE

SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE DETAIL.

ELECTRICAL CONTRACTOR ISRESPONSIBLE FOR FOLLOWING ALLLOCAL CODES FOR ROUGHINSTALLATION. HENRY SCHEIN TOMAKE FINAL CONNECTIONS.

X-RAY EXPOSURE BUTTON

ELECTRICIAN TO PROVIDE AFLUSH-MOUNTED SINGLE GANGJUNCTION BOX & 3/4" CONDUIT W/PULL-WIRE BETWEEN EXPOSUREBUTTON & X-RAY MASTERCONTROL/UNIT.

PROVIDED BY HENRY-SCHEIN DENTAL, INSTALLED BY ELECTRICIAN.

X-RAY EXPOSURE BUTTON (TYP.)

VERIFY WIRING REQUIREMENTSBETWEEN EXPOSURE BUTTONAND X-RAY MASTERCONTROL/UNIT WITHMANUFACTURER'S INSTALLATIONMANUAL.

HEIGHT TO COMPLY WITH LOCALHANDICAP REQUIREMENTS.

D-9CI-CAT CABLING DETAILNOT TO SCALE

EXPOSURE BUTTON REQUIREMENTS (SEEHENRY SCHEIN REP TO VERIFY)ELECTRICIAN TO PROVIDE 1" CONDUIT &PULL-STRING TO HOUSE 8 PIN CONNECTORCABLE (50' PROVIDED BY MFR.) FROM I-CATLOCATION TO EXPOSURE BUTTON.

ELECTRICIAN TO INSTALL 120V, 20ADEDICATED RECEPTACLE AT I-CATLOCATION.

*LEAVE APPROX. 6'-8' OF ETHERNET CABLE EXPOSEDAT I-CAT LOCATION FOR PROPER ROUTING TO I-CAT.

POWER & INTERNET CONNECTION FORCOMPUTER. SEE HENRY SCHEIN FORSPECIFICATIONS ON MANUFACTURER-PROVIDED CPU/MONITOR.

COMPUTER WORKSTATIONLOCATION

EXPOSURE BUTTONLOCATION

I-CATLOCATION

9B

9C

ELECTRICIAN TO PROVIDE 3/4" CONDUIT &PULL-STRING TO HOUSE CAT5 ETHERNET CABLE(50' PROVIDED BY MFR.) FROM I-CAT LOCATION TOCOMPUTER. FOR LONGER RUNS ADDITIONALCABLING TO BE PROVIDED BY ELECTRICIAN.

CONDUIT CAN BE TERMINATED ABOVE CEILING OR RUNCONTINUOUS IN PLENUM. VERIFY LOCAL CODEREQUIREMENTS & CONFIRM WITH HENRY SCHEIN REP.

ELECTRICIAN TO PROVIDE 3/4" CONDUIT &PULL-STRING TO HOUSE CAT5 ETHERNET CABLE(50' PROVIDED BY MFR.) FROM I-CAT LOCATION TOCOMPUTER. FOR LONGER RUNS ADDITIONALCABLING TO BE PROVIDED BY ELECTRICIAN.

*DRAWING IS FOR REFERENCE PURPOSES.PLEASE SEE HENRY SCHEIN REP. FOR I-CATINSTALLATION GUIDE.

1" CONDUIT

3/4" CONDUIT

*STATE OR LOCAL RADIATION CODES MAYREQUIRE AN INTERLOCK SYSTEM (DOORACTIVATED SWITCH) AND/OR A WARNINGSYSTEM (LIGHT OR ALARM IN HALLWAY).THESE COMPONENTS & WIRING AREAVAILABLE UPON REQUEST.

NOT TO SCALED-14

DENTAL STERILIZER (STATIM)

ELECTRICAL: ELECTRICAL CONTRACTORTO PROVIDE AND INSTALL A BOX WITH ADEDICATED 115V, 20A CIRCUIT & SINGLERECEPTACLE AT 30" A.F.F.

CONDENSING TANK (PROVIDED WITHUNIT)

SLIDE-OUT WATER RESISTANT SURFACEMUST BE CAPABLE OF A 100 LB LOAD.

NOTES:OUTLET LOCATIONS ARE APPROXIMATE AND SHOULD BE VERIFIED BY HENRYSCHEIN EQUIPMENT REP AND CABINET MAKER.

DENTAL STERILIZER PROVIDED AND INSTALLED BY HENRY SCHEIN DENTAL

PROVIDE A 9/32" HOLE IN COUNTERBEHIND UNIT TO RUN TUBING.

NOT TO SCALED-14A

STACKED STERILIZERS (AUTOCLAVES)

ELECTRICAL: ELECTRICAL CONTRACTORTO PROVIDE AND INSTALL A BOX WITH ADEDICATED 115V, 20A CIRCUIT & SINGLERECEPTACLE AT 51" A.F.F.

ELECTRICAL: ELECTRICAL CONTRACTORTO PROVIDE AND INSTALL A BOX WITH ADEDICATED 115V, 20A CIRCUIT & SINGLERECEPTACLE AT 37" A.F.F.

SLIDE-OUT WATER RESISTANT SURFACESMUST BE CAPABLE OF A 100 LB LOAD.

NOTE:DENTAL STERILIZERS PROVIDED AND INSTALLED BY HENRYSCHEIN DENTAL.OUTLET LOCATIONS ARE APPROXIMATE AND SHOULD BEVERIFIED BY HENRY SCHEIN EQUIPMENT REP AND CABINETMAKER.

NOT TO SCALED-15

ULTRASONIC CLEANER

NOTE:EXACT LOCATION AND SINK SIDE MAYVARY. TO BE SPOTTED BY HENRYSCHEIN DENTAL EQUIPMENT REP.

ELECTRICAL: ELECTRICALCONTRACTOR TO PROVIDE ANDINSTALL A BOX WITH 115V DUPLEXRECEPTACLE AT 18" A.F.F.

RECESSED ULTRASONIC CLEANER &GENERATOR PROVIDED AND INSTALLEDBY HENRY SCHEIN DENTAL.

PLUMBING CONTRACTOR TO PROVIDE &INSTALL A 3/4" DISHWASHER TEE ON DRAINSTAND PIPE FOR ULTRASONIC DRAIN HOSE.REMOTE POWER GENERATOR

ULTRASONICCLEANERGENERATOR

NOT TO SCALE

ELECTRICAL: ELECTRICAL CONTRACTORTO PROVIDE AND INSTALL A BOX WITH120V, 20A CIRCUIT & DUPLEXRECEPTACLE AT 44" A.F.F.

QUATTROcare UNIT PROVIDED ANDINSTALLED BY HENRY SCHEIN DENTAL.

D-15BKAVO QUATTROcare

OUTLET LOCATIONS ARE APPROXIMATEAND SHOULD BE VERIFIED BY HENRYSCHEIN EQUIPMENT REP.

MIN. 8" SIDE CLEARANCE FROM ALLWALL AND CABINET SURFACES. MIN.20" SIDE CLEARANCE FROM ALLIGNITION SOURCES, LIGHT SWITCHES,AND MAIN OUTLETS.

UNIT 11" DEEP WHEN CLOSED.PROVIDE AN ADDITIONAL 8" IN FRONTOF UNIT FOR WHEN FLAP IS OPEN.

COMPRESSED AIR: PLUMBINGCONTRACTOR TO PROVIDE ANDINSTALL A COMPRESSED AIR SUPPLYLINE AT 44" A.F.F. STUB-OUT FROMWALL AND TERMINATE WITH A 90° 1/4"COMPRESSION STOP.

NOT TO SCALED-16

MODEL TRIMMER & GLECO PLASTER TRAP

NOTE:EXACT LOCATION AND SINK SIDE MAY VARY. TO BESPOTTED BY HENRY SCHEIN DENTAL EQUIPMENT REP.

BACK FLOW PREVENTION MAY BE REQUIRED,CHECK LOCAL CODES.

WATER: PLUMBING CONTRACTOR TO PROVIDE ANDINSTALL A 1/2" COPPER (OR ACCEPTED) COLDWATER SUPPLY LINE AT 44" A.F.F. STUB-OUT FROMWALL AND TERMINATE WITH A 90° 3/8" COMPRESSIONSTOP.

ELECTRICAL: ELECTRICAL CONTRACTOR TOPROVIDE AND INSTALL A BOX WITH 115V DUPLEXRECEPTACLE AT 44" A.F.F.

MODEL TRIMMER PROVIDED AND INSTALLED BYHENRY SCHEIN DENTAL.

PLASTER TRAP PROVIDED BY HENRY SCHEINDENTAL.

PLASTER TRAP REPLACES THE STANDARD P-TRAPAT SINK. PLUMBING CONTRACTOR TO PROVIDETYPICAL DRAIN STUB-OUT FROM WALL.

SINK BASIN MUST BE STANDARDDEPTH. PLASTER TRAP CANNOT BEINSTALLED UNDER A DEEP BASIN

CABINET BASE

LOOSE DRAIN HOSE FROM MODEL TRIMMER INTOSINK.

D-25AIRSTAR-40 AIR COMPRESSORNOT TO SCALE

NOTES:1. 1/2" FNPT SHUT-OFF VALVE AND A 4'-0" PRESSURE HOSE (SUPPLIED W/ UNIT)2. AIR DISTRIBUTION PIPING: 1/2" TYPE "L" OR "K" COPPER3. ALLOW 12" SERVICE CLEARANCE ON ALL SIDES OF UNIT

1/2" MNPT COMPRESSEDAIR LINE (PROVIDED BY PLUMBER)

2" PIPE FORFRESH AIR INTAKE

ROUTE TODESIGNATEDREMOTE AREAFOR FRESH AIRINTAKE

BOOST TRANSFORMER(OPTIONAL)

BUILDING POWERSUPPLY PANEL

REMOTE AIRMANIFOLD(OPTIONAL)

13" MAX

3' MAX

2' MAX

24V REMOTESHUTOFF PANEL

24 V CONTROL WIRING18 GAUGE4 CONDUCTOR

HP 3.0208 / 230200 / 250

PRODUCT SPECIFICATIONS

200 / 25016

30

SITE REQUIREMENTS

NOTES:DETAIL PROVIDED FORINFORMATION ONLY. REFER TOMANUFACTURER'SINSTALLATION MANUAL.INSTALLATION MUST CONFORMTO ALL LOCAL ELECTRICALAND PLUMBING CODES.

VOLTAGE RATINGVOLTAGE MIN/MAXDIMENSIONS (H X W X D)

VOLTAGE MIN/MAXFULL LOAD AMPSMIN. CIRCUIT BREAKERRATING (AMPS)

NUMBER OF USERS

255UNIT WEIGHT (LBS)

4 - 5

30.5 x 32.5 x 20

6-20R NEMAOUTLET

DRIP LEG W/DRAIN VALVE

THIS UNIT AND ALL COMPONENTS ARE SPECIFIED AS A“DENTAL AIR SUPPLY SYSTEM.”  REFER TO NFPA 99, 2015,5.3.3.6 FOR REGULATIONS AND REQUIREMENTS.

SPE.1

24 x 361/4"=1'-0"MECHANICAL

DETAILS

THIS

DO

CUM

ENT

HAS

BEEN

PRE

PARE

D A

S A

N IN

STRU

MEN

T O

FPR

OFE

SSIO

NA

L SE

RVIC

E. I

T IS

NO

T AN

ARC

HITE

CTU

RAL

PLA

NA

ND

IS N

OT I

NTE

NDE

D FO

R C

ON

STRU

CTIO

N.

THE

IDEA

S/D

ESIG

N IN

CLU

DED

HER

EIN

ARE

THE

SO

LE P

ROPE

RTY

OF

HEN

RYSC

HEIN

DEN

TAL

AN

D A

RE P

ROTE

CTE

D U

ND

ER C

OPY

RIG

HT.

THES

E PL

AN

S M

AY

NO

T BE

USE

D O

R RE

PRO

DUC

ED W

ITHO

UTEX

PRES

SED

WRI

TTEN

CO

NSE

NT

OF

HEN

RY S

CHE

IN A

ND

FUL

LPA

YMEN

T O

F A

NY

ASS

OC

IATE

D D

ESIG

N F

EES.

ALL

DIM

ENSI

ON

S A

RE S

UBJE

CT T

O J

OB-

SITE

VER

IFIC

ATIO

N.

REVISIONS:

HENRY SCHEIN REP:

PRO

JEC

T:

LOC

ATIO

N:

SCALE: SHT. SIZE:INT.SQ.FT.=

2017 by HENRY SCHEIN, INC.c

CENTER:

PHONE #:

DRAWING NAME:

PROJECT START DATE:

FINALS START DATE:

DRAWN BY:FINALS BY:CHECKED BY:

1092

0 W

LIN

CO

LN A

VE,

WES

T A

LLIS

, WI

5322

7

HEN

RYSC

HEI

NR

DR

. S

AM

ER

OB

EID

ROC

HEST

ER H

ILLS

MIC

HIG

AN

FRANK WISNEWSKI

DETROIT, MI

(248) 755-0149

OBEID-1-D

08/11/2017

08/11/2017

ARCHTLTLBZ

--/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- ---

PER ARCH

AutoCAD SHX Text
VERIFY W/
AutoCAD SHX Text
VERIFY W/
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4 1/2"
AutoCAD SHX Text
4 1/2"
AutoCAD SHX Text
60" A.F.F.
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
h
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
20"
AutoCAD SHX Text
20"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
21"
AutoCAD SHX Text
21"
Page 12: invitefiles.thealangroup.com · 3r7c 3 7c 3 7c 3 3 3 3 3 7c 7c 7c 7c 13 11 16 17 1113 30g 15 15b 25 27b 30 30e 29a 33 note: henry schein will supply all dental templates on job site

FOR ROUGH BIDDING ONLY

FOLLOW ALL LOCAL CODESFOR INSTALLATION. SEE MFR.

INSTALL GUIDE FOR MOREINFORMATION.

USERS (MAX) 10205-240VSINGLE PHASE

20A15A

VOLTAGE(MIN-MAX)BREAKER SZ.FULL LOAD

ELECTRICAL DISCONNECT BOX BY ELECTRICIAN IFMAIN BREAKER PANEL IS NOT IN EQUIPMENTROOM. MOUNT WITHIN 3' OF INSTALL CENTERLINE.

112" DRAIN LINE CAN BE HARD-PLUMBED

TO A VENTED LINE OR A FLOORDRAIN/SINK WHERE ALLOWED BY CODE.DRAIN MUST BE LOWER THAN TANK.

(1) 3" or (2) 2" INSULATED METAL PIPE FOR HEATEXHAUST. (1) 3" or (2) 2" SCH. 40 PVC PIPE CAN BEUSED WHEN CONNECTED TO HEAT EXCHANGER.DRIP-LEG PROVIDED FOR CONDENSATION. SEE"EXHAUST DETAIL" FOR ADDITIONAL INFORMATION.

VAC. LINE OUT TOROOMS. 2" OR 21

2" SCH.40 PVC. TERMINATE WITHA 2" FNPT FITTING FORCONNECTION TO UNIT.

COLD WATER LINE FOR TANK CLEAN-OUT BYCONTRACTOR. 1/2" FNPT SHUT-OFF VALVEWITHIN 10' OF INSTALL.

TO R

OO

F

PUMP

EXHAUST DETAIL

HEAT EXCHANGER(PROVIDED)DRIP LEG ASSEM.(PROVIDED)TERMINATE ABOVEDRAIN HEIGHT IFCLOSED DRAIN ISUSED.

FLEX TUBING(PROVIDED)

EXHAUST TO OUTSIDE(NOT PROVIDED)

D-27BAIR TECHNIQUES MOJAVE 2V5 VACUUMNOT TO SCALE (TANK AND PUMPS SIDE BY SIDE)

MAX WATTS/HRMAX BTUS/HR

PUMP

PER

PUM

P

UP TO AMALGAM SEP'R(29A) IF SHOWN ON PLAN,OTHERWISE TO TANK. USE1-1/2" CLEAR BLUE FLEXPVC (PROVIDED).

V5 PUMP25"W x 21"D

17"H145 LBS. MT10

SEPARATORTANK

29"W x 22"D33"H

75 LBS.

V5 PUMP25"W x 21"D

17"H145 LBS.

POWER FOR MASTER CONTROLLER UNIT.DEDICATED STANDALONE 120V, 5AGROUNDED RECEPTACLE. RECEPTACLE TO BESUPPLIED AND INSTALLED BY ELECTRICIAN.

4,49015,320

DATA DROP: EXACT LOCATION TBD BYHENRY SCHEIN REP.

D-29ASOLMETEX Hg5 AMALGAM SEPARATORNOT TO SCALE

NO ELECTRICALREQUIREMENTS/MOVINGPARTS. DOES NOT AFFECTSUCTION PRESSURE.

FROMTREATMENT

ROOMSTO PUMP

ORTANK INLET

NOTES:1. THE INLET TO THE Hg 5 CAN BE

INSTALLED BELOW OR LOWER THANTHE INLET TO THE VACUUM SYSTEM.

2. IF THE VACUUM LINES FROM THETREATMENT ROOMS COME UP FROMTHE FLOOR TO THE VACUUM SYSTEM,THE INLET TO THE Hg 5 MUST BEINSTALLED NO HIGHER THAN 6"ABOVE THE VACUUM INLET.

3. IF THE VACUUM LINES FROM THETREATMENT ROOMS COME FROM THECEILING DOWN TO THE VACUUMSYSTEM, THE Hg 5 SHOULD BEINSTALLED INTO THE PIPING RUNBETWEEN THE CEILING AND THEVACUUM SYSTEM.

4. SEE MANUFACTURER'S SPECIFICATIONMANUAL PRIOR TO INSTALLATION.

1-1/4"INLET

1-1/2" OUTLET

D-30MASTER WATER SHUT-OFF VALVENOT TO SCALE

STUB PIPE OUT OFWALL 6"

3/4" UNION (2 PLACES)(PROVIDED BY PLUMBER)

24V CONTROL WIRES

115V WALL OUTLETWITHIN 5' OF WATERFILTER BYPASS.

D-30EDENTAL WATERLINE TREATMENT SYSTEMNOT TO SCALE

DISTRIBUTION MANIFOLD

MANIFOLD PRESSURE GAUGE

MIX

ING

CHA

MBE

R

BYPASS LINE(CONNECT ONLY IF NECESSARY)

1/4" O.D. COPPER LINESONLY. LINES TO FEED TREATEDWATER TO EACH TREATMENTROOM. COPPER LINES TO BESUPPLIED BY CONTRACTOR.

1/4" O.D. POLY TUBING

COMPRESSED AIR FROMDENTAL AIR COMPRESSORTRUNK LINE

MUL

TI-ST

AG

EBI

O F

ILTE

R

MUL

TI-ST

AG

EBI

O F

ILTE

R

ACCESS PORT

MOUNTING CLIPS (TYP.)

TREATMENT ROOM BALL VALVES

DRAIN AIR GAP ASSEMBLY(MEETS ASME A112.1.2-1991,BOCA P-201.0 AND P-1505.11)

VISTACHECK DUAL BACKFLOWPREVENTERS (TYP). (ASMEA112.18.3M, A112.18.1M,NSF 61/9 & CSA B125 COMPLIANT)

VISTACHECK BACKFLOWPREVENTER

1.5" DRAIN WITH TRAP TO BESUPPLIED BY CONTRACTOR.

SHUTOFF VALVES (SEE MANUALFOR MULTIPLE VALVE CONF.)

CHECK VALVE

COLD WATER FROM MAINSUPPLY AFTER SHUT-OFFSOLENOID

FILTERED WATER TOMIXING CHAMBER

PRESSURE REGULATORS(SET TO 40 PSI)

INJECTION PORT

CONTROL MANIFOLD &PRESSURE GAUGE

VISTACLEAR MODEL 1000-28-HP SPECIFICATIONSMAXIMUM TEMPERATURE..................................................100°FMINIMUM TEMPERATURE.................................................... 45°FMAXIMUM PRESSURE......................................................100 PSIMINIMUM PRESSURE......................................................... 30 PSIOPTIMAL PH RANGE..................................................... 6.5 - 8.5MAXIMUM PH RANGE...................................................5.5 - 9.5MAXIMUM INFLUENT MANGANESE............................0.05 PPMMAXIMUM INFLUENT IRON............................................0.1 PPMMAXIMUM INFLUENT HYDROGEN SULFIDE...................0.5 PPMMAXIMUM INFLUENT CHLORINE/CHLORAMINE.............5 PPMMAXIMUM CONTINUOUS FLOW..............0.75 GPM (2.84 LPM)FILTER SERVICE LIFE (EACH)............1 YR OR 800 GAL (3,028 L)FILTER ELEMENT REPLACEMENT ORDER #........................R9721

WATER SOURCE:WATER TO BE TREATED BY THE VISTACLEAR SYSTEM CANCOME FROM MUNICIPAL WATER, PRE-TREATED WELL WATEROR ANY OTHER POTABLE, PRESSURIZED SUPPLY. THE SYSTEM ISDESIGNED TO FILTER ONLY COLD WATER.

DRAINS:THE SYSTEM DRAIN IS FOUND AT THE BOTTOM OF THE MIXINGCHAMBER AND SHOULD BE CONNECTED WITH CLEARTUBING TO THE BOCA/ANSI APPROVED AIR GAP DRAIN THATIS INCLUDED WITH EACH SYSTEM. IT IS DESIGNED TO BESOLVENT WELDED TO A 1 1/2” PVC STANDPIPE (12”MINIMUM) WITH TRAP (SEE DRAWING). PLEASE CHECK YOURLOCAL PLUMBING CODES FOR PROPER DRAIN INSTALLATIONREGULATIONS AND TECHNIQUES.

IMPORTANT NOTES:· SYSTEM IS FACTORY-BUILT AND MOUNTED ON 3/4"

VINYL-COATED BOARD. ITEMS WITH SOLID LINES AREPROVIDED AND INSTALLED BY HENRY SCHEIN DENTAL,ITEMS SHOWN AS DASHED LINES ARE TO BE PROVIDED BYTHE PLUMBING CONTRACTOR.

· PRESSURIZED SUPPLY OF WATER (POTABLE MUNICIPALWATER OR PROPERLY TREATED WELL WATER), COMPRESSEDAIR AND A DRAIN SHOULD BE LOCATED NEARBY THESYSTEM.

· COMPRESSED AIR AND WATER SUPPLY SHUT-OFF VALVESSHOULD BE CHROMED BRASS AND HAVE 3/8" OR 1/4" FNPTTHREADS FOR CONNECTION TO SYSTEM USING PROVIDEDNPT X TUBE ADAPTER.

· SYSTEM CAN BE FLUSH-MOUNTED ON A WALL BUT SHOULDBE PROTECTED FROM FREEZING, CONTINUOUS EXPOSURETO DIRECT SUNLIGHT AND/OR FLUORESCENT LIGHTING.

· SYSTEM CAN BE MOUNTED INSIDE CABINETRY, AS THIS IS THEPREFERRED METHOD, ALLOW 1" MINIMUM LEFT AND RIGHT,6" TOP AND BOTTOM FOR MAKING CONNECTIONS. ALLOWMINIMUM OF 5-1/2" FOR CABINET DEPTH TO INSURE DOORCLOSURE.

· ALWAYS MOUNT SYSTEM VERTICALLY AND AT A HEIGHTTHAT WILL ALLOW EASY ACCESS TO THE DISTRIBUTIONMANIFOLD VALVES ON A REGULAR BASIS.

· WHEREVER POSSIBLE, LOCATE AT LEAST ONE OF THEANCHORS SO THAT IT PENETRATES A STUD OR OTHERSUPPORT STRUCTURE. IF NO STUDS ARE AVAILABLE, BECERTAIN TO USE PROPER ANCHORS FOR MOUNTING ONWALLBOARD.

· EACH UNIT WEIGHS LESS THAN 25 LBS., MOUNTING CAN BEACCOMPLISHED USING STANDARD LAG SCREWS OFPROPER LENGTH. TRY TO LOCATE ANCHOR PILOT HOLESBEHIND FILTER HOUSINGS AND MANIFOLDS IN ORDER TO“HIDE” ANCHORS. SIMPLY REMOVE THE FILTER HOUSING(S)AND/OR PULL THE DESIRED FILTER / MANIFOLD OUT OF THECLIPS, DRILL PILOT, ANCHOR AND THEN REPLACE.

(C)2002 VISTA RESEARCH GROUP, LLC P.O. BOX 321, ASHLAND OHIO 44805-0321 (USA & WORLDWIDE PATENTS PENDING)

· A DEDICATED 1/4" O.D. COPPER TUBE MUST BE RUN FROMSYSTEM TO EACH TREATMENT ROOM. NOTE ROUGH-IN"ON-CENTER" DIMENSIONS FOR TUBES AT THE TOP OF THESYSTEM. IF SYSTEM IS TO BE INSTALLED IN ENCLOSURE, STUB1/4" TUBES 2" INTO THE ENCLOSURE. ALL TUBING TO HAVESQUARE-CUT ENDS WITH NO BURRS AND NO SCARS ON THESURFACE OF THE TUBING.

· A STANDARD SHUT-OFF VALVE SHALL BE INSTALLED AT THETERMINATION OF EACH 1/4" O.D. TUBE IN EACH TREATMENTROOM. (NOT SHOWN IN THIS DRAWING.)

· AIR AND WATER SUPPLY LINES FEEDING THIS SYSTEMSHOULD BE A MINIMUM OF 3/8" COPPER.

7 TREATMENT ROOMSD-30G

PELTON & CRANE VISTAPURENOT TO SCALE

PREFILTER

D/ I #2

D/ I #1

HYPERFILTRATION

POLISHING

101

102

103

104

105

106

FROM H20 SUPPLY(RED)

AIR GAP DRAINFITTING

SYSTEMMANIFOLD

AUTOSHUT-OFF

VALVE

PERMEATEPUMP

DUAL TDSMETER

2.7 GALLON WATERSTORAGE TANK

(BLACK)

(NEUTRAL)

WATER STORAGETANK SHUT-OFF VALVE

INJECTIONPORT

ASSEMBLY

(BLUE-COILED)AUTOCLAVEFILLER WAND

(WHITE)LEAD-FREE BOTTLEFILLING FAUCET

SYSTEM WATERSHUT-OFF

1

4

3

2

5

NOTES:IF NOT ALREADY MOUNTED IN ANOTHER PRODUCT (STERI CENTER) MOUNTNEAR COLD WATER SOURCE AND 1-1/2" DRAIN.PLUMBING CONTRACTOR IS TO COMPLY TO ALL LOCAL PLUMBING CODES.

SEE PELTON AND CRANEINSTALLATION GUIDE ANDMANUAL PRIOR TO INSTALL.

D-32AIRTECH CONTROL PANEL (3 SWITCH)NOT TO SCALE

VERTICAL WALL STUDSPLACED 16" O.C.

2 GANG METAL OR PLASTICSWITCH BOX BASED ON LOCALCODES. PROVIDED & INSTALLEDBY ELECTRICAL CONTRACTOR.

24V, 18/4 INTERCONNECT CABLEFROM EACH PUMP,COMPRESSOR AND WATERVALVE TO BE CONTROLLED.CABLES PROVIDED & INSTALLEDBY ELECTRICAL CONTRACTOR.

NOTE:WHEN RUNS EXCEED150' FROM UNITS TOCONTROL PANEL, USE16/4 CABLE.

REFER TO MANUFACTURER'SINSTALLATION GUIDE FOR FINAL WIREHOOKUP TO CONTROL PANEL.

END PANEL WITHSTUD STRAP

AIR,WATER & VAC. REMOTEPANEL KIT. PROVIDED BY HENRYSCHEIN DENTAL, INSTALLED BYELECTRICAL CONTRACTOR.

NOTE:WHEN USING WET-RING VACUUMPUMPS THE VACUUM SWITCH MUSTBE LOCKED OUT BY THE WATERSWITCH TO INSURE THAT WATER ISAVAILABLE BEFORE THE VACUUMSTARTS. REFER TOMANUFACTURER'S INSTALL GUIDEFOR DETAILS.

D-34NOT TO SCALE

SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE INFORMATION.

ELECTRICAL CONTRACTOR ISRESPONSIBLE FOR FOLLOWING ALLLOCAL CODES FOR ROUGHINSTALLATION. HENRY SCHEIN TOMAKE FINAL CONNECTIONS.

ACCUTRON GUARDIAN ALARM PANEL

ELECTRICIAN TO INSTALL A TWO-GANGJUNCTION BOX WITH MUD RING(PROVIDED BY MANUFACTURER). RUN3/4" CONDUIT FROM BOX TO 3" ABOVECEILING (CONTINUOUS TO MANIFOLD(33) WHEN PLENUM SPACE IS NOTACCESSIBLE).

ELECTRICIAN TO RUN 24V CONTROLWIRING (100' PROVIDED BYMANUFACTURER) BETWEEN ALARMPANEL AND NITROUS OXIDE MANIFOLD(33) AT FINISH. COIL 6-8" OF CABLEWITHIN BOX FOR FINAL CONNECTIONTO ALARM PANEL.

2x WALL STUD

D-33NOT TO SCALE

LINES TO OUTLETS (7), D.I.S.S.VALVES (7C), OR ZONEVALVE (34A) DEPENDING ONAPPLICATION. SEE PLAN.

CYLINDER RESTRAINTS(PROVIDED W/ MANIFOLD)

2 X 10 BLOCKING FLUSHWITH STUDS

LEVEL III FACILITY TANK ROOM WITH LESS THAN 3000 CU. FT. GAS (INCLUDING

STORAGE, EXCLUDING NITROGEN).

1/2" O.D. O2

115V DUPLEX OUTLETSUPPLIED AND INSTALLED BYCONTRACTOR WITHIN 4'-0"OF MANIFOLD

MANIFOLD

THE ELECTRICIAN SHALL EXTEND 24VCONTROL WIRING (100' PROVIDEDW/ MANIFOLD) BETWEEN THEMANIFOLD AND ALARM PANEL.

ACCUTRON GUARDIAN, GUARDIAN II N2O, O2 SYSTEM MANIFOLD

ALARM PANEL(SEE DETAIL D-34)

N2O N2O O2 O2

REGULATORS(PROVIDED W/ MANIFOLD)

TANK ROOM GUIDELINES:1. ROOM OR ENCLOSURE SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN STORAGE OF NONFLAMMABLE

GAS CYLINDERS, FULL OR EMPTY.2. AIR COMPRESSORS AND VACUUM PUMPS SHALL BE LOCATED IN A SEPARATE ENCLOSURE THAN THAT OF

THE CYLINDERS.3. ROOM OR ENCLOSURE SHALL BE CONSTRUCTED OF AN ASSEMBLY OF BUILDING MATERIALS WITH A FIRE

RESISTANCE RATING OF AT LEAST ONE HOUR.4. TANK ROOM DOOR SHALL LOCK.5. WHERE NATURAL VENTILATION IS PERMITTED, CONTRACTOR SHALL PROVIDE AND INSTALL TWO LOUVERED

OPENINGS, EACH HAVING A FREE AREA MINIMUM OF 72 SQ. INCHES. ONE LOCATED WITHIN 1'-0" OF THEFLOOR AND ONE LOCATED WITHIN 1'-0" OF THE CEILING. THE LOUVERS CAN BE IN THE WALL ADJACENT TOTHE DOOR OR IN THE DOOR, DEPENDING ON THE CLOSET. ANY ADDITIONAL VENTILATION TO BEDETERMINED BY ARCHITECT.

6. LOUVERED NATURAL VENTILATION OPENINGS SHALL NOT BE LOCATED IN AN EXIT ACCESS CORRIDOR.7. ATTACH TANK RESTRAINERS WITH LAG SCREWS. INSTALL 40” FROM THE FLOOR.8. TANK ROOM INSTRUCTIONS AND CAUTION FOR NONFLAMMABLE MEDICAL GASES IN USE MUST BE POSTED.

HENRY SCHEIN'S RESPONSIBILITIES:1. VERIFY THAT THE SYSTEM HAS BEEN TESTED FOR LEAKS.2. INSTALL WALL MOUNTS OR CABINET MOUNTS IN APPROPRIATE LOCATIONS.3. INSTALL COVER PLATES ON OUTLET STATIONS.4. INSTALL FLOWMETER HEADS.5. TEST THE SYSTEM FOR CROSSED LINES. REFER TO SECTION “TEST FOR CROSSED LINES” UNDER PLUMBERS

INSTRUCTIONS AND PERFORM TEST. DO NOT ASSUME THE SYSTEM HAS BEEN TESTED.6. TEST FOR FAILSAFE OPERATION.7. CHECK ALARM.8. DEMONSTRATE SYSTEM TO OWNER.

INSTALLATION REQUIREMENTS:TO ASSURE SAFE OPERATION AND CONFORMATION TO LOCAL FIRE CODES, ALL ACCUTRON INSTRUMENTMANIFOLD SYSTEMS ARE DESIGNED TO BE USED WITH SEDATION DELIVERY SYSTEMS MOUNTED INSIDE WALLSAND THEY MEET OR EXCEED THE GUIDELINES ESTABLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATIONFOR NONFLAMMABLE MEDICAL GAS SYSTEMS, NFPA 99. COPIES OF NFPA 99 OR PORTIONS THEREOF MAY BEOBTAINED BY WRITING TO:

NATIONAL FIRE PROTECTION ASSOCIATION1 BATTERYMARCH PARK, QUINCY, MA 02169-7471

VISITING http://www.nfpa.org, OR CALLING: 1-800-344-3555

THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. REFER TO MANUFACTURER'S INSTALLATION GUIDE FORADDITIONAL INFORMATION.POWER SUPPLY AND 6'-0"

INTERCONNECTING CABLE(PROVIDED W/ MANIFOLD)

O2 O2

SPARE CYLINDERS (OPTIONAL) MUST ALSO BE RESTRAINED TO WALL.

3/8" O.D. N2O

SEE PLAN AND MANUFACTURER'SSPECIFICATIONS AND INSTALL GUIDES FOR

MORE INFORMATION

NOTE: SEE MANUFACTURER'S INSTALLATION GUIDE FOR CONTRACTOR'S RESPONSIBILITIES

LEVEL III SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING REQUIREMENTS:1. NO MORE THAN 3000 CUBIC FEET TOTAL CAPACITY OF ALL GASES (EXCLUDING NITROGEN) CAN BE CONNECTED

AND IN STORAGE AT ONE TIME.2. ENCLOSURE FOR SUPPLY SYSTEMS SHALL BE PROVIDED WITH DOORS OR GATES THAT MAY BE LOCKED.3. WHERE NATURAL VENTILATION IS PERMITTED, CONTRACTOR SHALL PROVIDE AND INSTALL TWO LOUVERED OPENINGS,

EACH HAVING A FREE AREA MINIMUM OF 72 SQ. INCHES. ONE LOCATED WITHIN 1'-0" OF THE FLOOR AND ONE LOCATEDWITHIN 1'-0" OF THE CEILING. THE LOUVERS CAN BE IN THE WALL ADJACENT TO THE DOOR OR IN THE DOOR, DEPENDINGON THE CLOSET. ANY ADDITIONAL VENTILATION TO BE DETERMINED BY ARCHITECT.

4. EACH CYLINDER OF GAS SHALL HAVE A LISTED PRESSURE REGULATOR DIRECTLY CONNECTED.5. A PRESSURE RELIEF VALVE SET AT 50 PERCENT ABOVE (75 PSIG.) NORMAL LINE PRESSURE (50 PSIG).6. A SHUT-OFF VALVE OR CHECK VALVE SHALL BE INSTALLED DOWNSTREAM OF EACH PRESSURE REGULATOR.7. A PRESSURE GAUGE SHALL BE INSTALLED IN THE MAIN LINE ADJACENT TO THE ACTUATING SWITCH AND IT SHALL BE APPROPRIATELY LABELED.8. PIPING SHALL BE SEAMLESS TYPE K OR L (ASTM B88) COPPER TUBING, THOROUGHLY CLEANED OF OIL GREASE AND TEMPORARILY CAPPED OR PLUGGED TO PREVENT RECONTAMINATION.9. FLEXIBLE CONNECTORS OF OTHER THAN ALL-METAL CONSTRUCTION USED TO CONNECT OUTLETS OF PRESSURE REGULATORS TO FIXED PIPING SHALL HAVE A MINIMUM BURST PRESSURE OF 1000 PSIG AND SHALL NOT PENETRATE

WALLS, FLOORS, CEILINGS, OR PARTITIONS.10.BEFORE CLOSING OF THE WALLS, EACH SECTION OF THE PIPING SYSTEM, EXCLUDING MANIFOLD, SHALL BE SUBJECTED TO A MINIMUM PRESSURE TEST OF 60 PSIG WITH OIL-FREE, MEDICAL GRADE DRY NITROGEN. THIS PRESSURE TEST

SHALL BE MAINTAINED UNTIL EACH JOINT HAS BEEN EXAMINED FOR LEAKAGE, AND ANY LEAKS LOCATED SHALL BE REPAIRED AND RETESTED AS ABOVE. AFTER TESTING AS ABOVE, THE COMPLETELY ASSEMBLED PIPING SYSTEM SHALLBE SUBJECTED TO A 24-HOUR STANDING PRESSURE TEST AT 60 PSIG LINE PRESSURE USING REQUIRED TEST GAS.

11.PIPING SYSTEMS, WITH THE EXCEPTION OF NITROGEN SYSTEMS, SHALL BE CAPABLE OF DELIVERING 50 TO 55 PSIG TO ALL OUTLETS AT THE MAXIMUM FLOW RATE.12. ALL BRAZED JOINTS IN THE PIPING SHALL BE MADE UP USING BRAZING FILLER ALLOYS THAT BOND WITH THE BASE METALS BEING BRAZED AND THAT COMPLY WITH "SPECIFICATIONS FOR BRAZING FILLER METAL," ANSI/AWS A5.8. A)

COPPER-TO-COPPER JOINTS SHALL BE MADE USING A COPPER-PHOSPHORUS BRAZING FILLER ALLOY (BCUP SERIES) WITHOUT FLUX. B) DISSIMILAR METALS SUCH AS COPPER AND BRASS SHALL BE JOINED USING AN APPROPRIATE FLUXWITH EITHER A COPPER-PHOSPHORUS (BCUP SERIES) OR A SILVER (BAG SERIES) BRAZING FILLER ALLOY. APPLY FLUX SPARINGLY AND IN A MANNER TO AVOID LEAKING ANY EXCESS INSIDE OF COMPLETED JOINTS. USE OF PRE-FLUXEDROD IS ACCEPTABLE.

13. AUDIBLE AND NON-CANCELABLE VISUAL SIGNALS SHALL INDICATE IF THE PRESSURE IN THE MAIN LINE INCREASES OR DECREASES 20 PERCENT FROM THE NORMAL OPERATING PRESSURE, AND SHALL BE INSTALLED IN THE OFFICE ORPRINCIPAL WORKING AREA OF THE INDIVIDUAL RESPONSIBLE FOR THE MAINTENANCE OF THE MEDICAL GAS SYSTEM, TO ASSURE CONTINUOUS SURVEILLANCE.

14. WHERE THE CENTRAL SUPPLY IS REMOTE FROM THE MEDICAL GAS SYSTEMS USE POINTS, THE MAIN SUPPLY LINE SHALL BE PROVIDED WITH A SHUT-OFF VALVE SO LOCATED IN THE TREATMENT FACILITY AS TO BE ACCESSIBLE FROMUSE-POINT LOCATIONS IN AN EMERGENCY.

15. OUTLET STATIONS SHALL BE DESIGNED SO THAT PARTS OR COMPONENTS THAT ARE REQUIRED TO BE GAS SPECIFIC CANNOT BE INTERCHANGED BETWEEN STATION OUTLETS FOR DIFFERENT GASES.16.LABELING SHALL APPEAR ON THE PIPING AT INTERVALS OF NOT MORE THAN 20 FT. AND AT LEAST ONCE IN EACH ROOM AND EACH STORY TRAVERSED BY THE PIPING SYSTEMS.

SPE.2

24 x 361/4"=1'-0"MECHANICAL

DETAILS

THIS

DO

CUM

ENT

HAS

BEEN

PRE

PARE

D A

S A

N IN

STRU

MEN

T O

FPR

OFE

SSIO

NA

L SE

RVIC

E. I

T IS

NO

T AN

ARC

HITE

CTU

RAL

PLA

NA

ND

IS N

OT I

NTE

NDE

D FO

R C

ON

STRU

CTIO

N.

THE

IDEA

S/D

ESIG

N IN

CLU

DED

HER

EIN

ARE

THE

SO

LE P

ROPE

RTY

OF

HEN

RYSC

HEIN

DEN

TAL

AN

D A

RE P

ROTE

CTE

D U

ND

ER C

OPY

RIG

HT.

THES

E PL

AN

S M

AY

NO

T BE

USE

D O

R RE

PRO

DUC

ED W

ITHO

UTEX

PRES

SED

WRI

TTEN

CO

NSE

NT

OF

HEN

RY S

CHE

IN A

ND

FUL

LPA

YMEN

T O

F A

NY

ASS

OC

IATE

D D

ESIG

N F

EES.

ALL

DIM

ENSI

ON

S A

RE S

UBJE

CT T

O J

OB-

SITE

VER

IFIC

ATIO

N.

REVISIONS:

HENRY SCHEIN REP:

PRO

JEC

T:

LOC

ATIO

N:

SCALE: SHT. SIZE:INT.SQ.FT.=

2017 by HENRY SCHEIN, INC.c

CENTER:

PHONE #:

DRAWING NAME:

PROJECT START DATE:

FINALS START DATE:

DRAWN BY:FINALS BY:CHECKED BY:

1092

0 W

LIN

CO

LN A

VE,

WES

T A

LLIS

, WI

5322

7

HEN

RYSC

HEI

NR

DR

. S

AM

ER

OB

EID

ROC

HEST

ER H

ILLS

MIC

HIG

AN

FRANK WISNEWSKI

DETROIT, MI

(248) 755-0149

OBEID-1-D

08/11/2017

08/11/2017

ARCHTLTLBZ

--/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- -----/--/-- ---

PER ARCH

AutoCAD SHX Text
14 1/4"
AutoCAD SHX Text
14 1/4"
AutoCAD SHX Text
60" A.F.F.
AutoCAD SHX Text
60" A.F.F.