Upload
jesusra
View
840
Download
18
Tags:
Embed Size (px)
Citation preview
SIMODRIVE 611 Analog SystemTransistor PWM Inverters for AC Feed Drives and AC Main Spindle Drives
Installation and Startup Guide 04.97 Edition
Service Documentation
SIMODRIVE 611 Analog SystemTransistor PWM Inverters forAC Feed Drives andAC Main Spindle Drives
StartUp Guide
Service Documentation
Valid for
Equipment series 6SN11
04.97 Edition
Foreword
General information AL
Supply infeed NE
Feed modules VS
Feed modules,resolver control VR
Main spindle modules HS
Induction motor modules AM
Spare parts ES
Complete index
User Documentation
SINUMERIK840D/810D/FMNC
SINUMERIK
Overview of SINUMERIK 840D/810D/FMNC Documentation (08.97)
Brochure Catalog Ordering Info. NC 60.1Technical Info. NC 60.2
ManualConfiguring (HW) FMNC 810D 840D
Description ofFunctions Drive Functions
Description ofFunctions Basic Machine Extended Functions Special Functions
SINUMERIK SINUMERIK
611D840D/810D
SINUMERIK
840D/810D/FMNC
SINUMERIK
840D/810D
840D/810D/FMNC/611
SIMODRIVEAccessories
CatalogAccessories NCZ
SINUMERIKSIROTEC
SINUMERIK840D/810DFMNC
Lists
SINUMERIK
840D/810D/FMNC
Description ofFunctionsOperator InterfaceOP 030
Installation &Start-up Guide FMNC 810D 840D/611D
SINUMERIK
Description ofFunctionsTool Manage-ment
SINUMERIK
840D
Description ofFunctionsDigitizing
SIMODRIVE
611D
SINUMERIK
SINUMERIK
840D/810D/FMNC
Configuring KItMMC100/101 Configuring Syntax Development Kit
SINUMERIK
840D/810D/FMNC
Screen KitMMC100/101SW Update andConfiguration
SINUMERIK840D/810D/FMNC
Operators Guide Short Guide Operators Guide
SINUMERIK840D/810D/FMNC
SINUMERIK840D/810D/FMNC
ManualOperatorComponents(HW)
840D/810D/FMNC
SIMODRIVE
SIMODRIVE
SINUMERIK
SINUMERIK
Description ofFunctionsSINUMERIKSafety Integrated
SIMODRIVE
SINUMERIK
840D/810D/FMNC
SIMODRIVE
611, MotorsDOC ON CDThe SINUMERIK System
General Documentation
Electronic Documentation
Manufacturer / Service Documentation
Manufacturer / Service Documentation
SINUMERIK840D/810D/FMNC
SINUMERIK840D/810D/FMNC
User Documentation
Diagnostics GuideOperators Guide Unit Operator Panel HPU
AUTOTURN Short Guide Programming (Part 1) Setup (Part 2)
SINUMERIK840D/810D/FMNC
ProgrammingGuide Short Guide Fundamentals Advanced Cycles Measuring Cycles
Description ofFunctions MANUALTURN SHOPMILL
Description ofFunctionsSynchronousactionsWood, Glass,Ceramics
810D
SINUMERIK
Operators Guide MANUALTURN SHOPMILL
810D
Manufacturer / Service Documentation
SINUMERIK840D/810D
Description ofFunctionsComputer LInk
SINUMERIK
840D/810D
Description ofFunctionsOperator InterfaceHPU
SIMODRIVE documentation
Edition coding
Brief details of this edition and previous editions are listed below
The status of each edition is shown by the code in the Remarks column.
Status code in the Remarks column:
A New documentation.. . . . B Unrevised reprint with new Order No.. . . . C Revised edition with new status . . . .
If factual changes have been made on the page since the last edition, this is indicated by a new edition coding in the header on that page.
07.94 6SN11970AA600BP0 A10.94 6SN11970AA600BP1 C12.94 6SN11970AA600BP2 C03.96 6SN11970AA600BP3 C04.97 6SN11970AA600BP4 C
Dieses Buch ist Bestandteil der Dokumentation auf CDROM (DOCONCD)
09.97 6FC5 1986CA000AG0 (840C Read) C09.97 6FC5 1986CB000AG0 (840C Print) C09.97 6FC5 1986CC000AG0 (840C Net) C
09.97 6FC5 2984CA000AG0 (840D Read) C09.97 6FC5 2984CB000AG0 (840D Print) C09.97 6FC5 2984CC000AG0 (840D Net) C
This publication was produced on Interleaf V 5.4
The reproduction, transmission or use of this document or itscontents is not permitted without express written authority. Offenderswill be liable for damages. All rights, including rights created by patentgrant or registration of a utility model or design, are reserved.
Siemens AG 1994, 1996, 1997 All Rights reserved.
Functions may be executable in the control but are not described inthis documentation. No claims can be made on these functions ifincluded with a new shipment or when involved with service.
We have checked the contents of this document to ensure that theycoincide with the described hardware and software. The informationin this document is regularly checked and necessary corrections areincluded in reprints. We are thankful for any recommendations forimprovement.
Subject to change without prior notice.
SiemensAktiengesellschaftOrder No. 6SN11970AA600BP4Printed in the Federal Republic of Germany
1 Siemens AG 1997 All Rights reserved SIMODRIVE 611A I ll i d S U G id /IAA/ 04 97 Edi i
3ls
07.94
ii Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Qualified personalFor the purpose of these Instructions and product labels, a qualified person issomeone who is familiar with the installation, mounting, startup and operationof the equipment and the hazards involved. He or she must have the followingqualifications:
Trained and authorized to energize, deenergize, clear, ground and tag cir-cuits and equipment in accordance with established safety procedures.
Trained in the proper care and use of protective equipment in accordancewith established safety procedures.
Trained in rendering first aid.
! DangerThis symbol in the document indicates death, severe personal injury or substantial property damage will result if proper precautions are not taken.
! WarningThis symbol appears in the document, if death, severe personal injury or pro-perty damage can result if proper precautions are not taken.
! CautionThis symbol appears in the document indicating that minor personal injury ormaterial damage can result if proper precautions are not taken.
! WichtigThis symbol appears in the documentation if a particular issue is significant.
Note
For the purposes of these Instructions, Note indicates information about theproduct or the respective part of the Instruction Manual which is essential tohighlight.
Definitions
07.94
iii Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
! WarningOperational electrical equipment has parts and components which are at ha-zardous voltage levels.Incorrect handling of these units, i. e. not observing the warning information,can therefore lead to death, severe bodily injury or significant material damage.Only appropriately qualified personal may commission/startup this equipment.This personal must have indepth knowledge regarding all of the warning infor-mation and service measures according to this Manual.Perfect, save and reliable operation of this equipment assumes that it has beenprofessionally transported, stored, mounted and installed as well as carefuloperator control and service.Hazardous axis motion can occur when working with the equipment.
Note
When handling cables observe the following
they must not be damaged
they must not be strained and
they must not come into contact with rotating components.
Note
It is not permissible to connect SIMODRIVE equipment to a supply system withELCBs (this restriction is permitted according to DIN VDE 0160, Section 6.5).When operational, protection against direct contact is provided in a form to al-low the unit to be used in enclosed electrical equipment rooms (DIN VDE 0558Part 1 / 07.87, Section 5.4.3.2.4).In compliance with DIN VDE 0160 / 05.88, all SIMODRIVE units are subject toa highvoltage test at the time of routine testing. If the electrical equipment ofindustrial tools is subject to a highvoltage test, all connections must be discon-nected so that sensitive electronic components in the SIMODRIVE converterare not damage (permissible according to DIN VDE 0113 / 06.93, Part 1, Sec-tion 20.4).
! WarningStartup/commissioning is absolutely prohibited until it has been ensured thatthe machine in which the components described here are to be installed, fulfillsthe regulations/specifications of the Directive 89/392/EWG.
07.94
iv Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
! WarningThe information and instructions in all of the documentation supplied and anyother instructions must always be observed to eliminate hazardous situations and damage.
For special versions of the machines and equipment, the information in theassociated catalogs and quotations applies.
Further, all of the relevant national, local and plant/systemspecific regulations and specifications must be taken into account.
All work should be undertaken with the system in a novoltage condition!
! WarningBefore commissioning 611D, it should be checked that the encoder cable doesnot have a ground fault.If ground faults occur, for loads which exert a force on the drive, uncontrolledmovement could occur. This no longer occurs for 6SN11180D20AA0, Version B.
07.94
v Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Electro Static Devices
Components which can be destroyed by electrostatic discharge are individualcomponents, integrated circuits, or boards, which when handled, tested, ortransported, could be destroyed by electrostatic fields or electrostatic di-scharge. These components are designated as ESDS (ElectroStatic DischargeSensitive Devices).Handling ESDS boards:
The human body, working area and packing should be well grounded whenhandling ESDS components!
Electronic boards should only be touched when absolutely necessary.
Components may only be touched, if you are continuously grounded through an ESDS wristlet, you are wearing ESDS shoes or ESDS shoe grounding strips in con-
junction with an ESDS floor surface. Boards may only be placed on conductive surfaces
(desk with ESDS surface, conductive ESDS foam rubber, ESDS packingbag, ESDS transport containers).
Boards may not be brought close to data terminals, monitors or televisionsets (a minimum of 10 cm should be kept between the board and thescreen).
Boards may not be brought into contact with materials which can be char-gedup and which are highly insulating, e. g. plastic foils, insulating desk-tops, articles of clothing manufactured from manmade fibers.
Measuring work may only be carried out on the boards if the measuring equipment is grounded (e. g. via the protective conduc-
tor) or for floating measuring equipment, the probe is briefly discharged before
making measurements (e. g. a bare control housing is touched). Only hold the control modules at the front panel
Note
Startup software is available for startingup/commissioning the main spindleand induction motor modules.
Startup software Order No.: 6SN11532AX10ABDocumentation Order No.: 6SN11970AA300P
ESD information
07.94
vi Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
SINUMERIK and SIMODRIVE Enhanced productivity as a result of fast, reliable commissioning
Sophisticated industrial electronics, as are involved here, have to be handledespecially carefully. We regularly evaluate and investigate equipment which isreturned and in so doing we have identified some of the main fault causes,which in some cases results from incorrect handling during commissioning andtroubleshooting.
The following check list should help you to simply commission the componentswe have supplied and guarantee a high availability when used in conjunctionwith your product or equipment.
Observe all of the ESD measures when handling components.
Tightenup all bolts and screws to the specified torque. Pay special atten-tion to the DC link bolt connections (1.8 Nm tightening torque).
Correctly insert all connectors and lock/screw into place.
Screw the control components into the power module.
Observe the poweron sequence in the Planning Guide.If the unit is frequently powereddown and up, the DC link charge circuit islockedout. The DC link can only be charged again after it has cooled downfor several minutes with the supply off.
Are there line supply/motor contactors connected to the drive converter?These are only switched in a nocurrent condition.
Ground all components and connect all of the shields. Connection X131 isgrounded.
Observe the load capability of the central power supply.
Only discharge the unit at the DC link buses through a minimum of 10 .
In operation, units with hard disks may only be stressed with a of max. 1 g(read/write error; defective).
Use the correct software for the particular unit.
Are OEM components (ISA/PCMCIA card) used? Their current drain mustlie within the specified values.
CRT monitors may not be subject to magnetic fields (e.g. power supply unitcoils).
When commissioning and fault finding, always proceed in a modular stepbystep fashion.This means: First commission the central controller and linesupply module, then connectup and commission the components one afteranother.
Handling
Check list
03.96
07.94
vii Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
The units are designed for the specified mechanical, climatic and electricalambient conditions. None of the limit values may be exceeded, neither inoperation nor during transport. Please pay specific attention to the following: line supply conditions
pollutants damaging gases climatic ambient conditions
storage/transport shock stressing vibration stressing ambient temperature
Further detailed information is provided in the Planning Guides and InstallationStartup Guides associated with our products.
Further information
03.96
07.94
viii Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
03.96
AL
ALi Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
General information (AL)
1 Permissible combinations of inverter modules and control cards AL/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AL
07.94
ALii Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
AL
Feed/main spindle controls with analog setpoint interface
07.94
AL/1-3 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Permissible combinations of invertermodules and control cards
Table 1-1 Selection table to set the current controller referred to the resulting inverter currents
SIMODRIVE 611 components
Feed
driv
e co
ntro
l, an
alog
1ax
is, u
ser
frien
dly
inte
rfac e
6SN1
118
0AA1
10A
A0
Feed
driv
e co
ntro
l, an
alog
1ax
is, s
tand
ard
inte
rface
6SN1
118
0AD1
10A
A0
Feed
driv
e co
ntro
l, an
alog
2ax
is, s
tand
ard
inte
rface
6SN1
118
0AE1
10A
A0
Feed
driv
e re
solve
r con
tr.,anal.
6SN1
118
0BJ1
10A
A0
1ax
is, s
tand
ard
inte
rface
Feed
driv
e re
solve
r con
tr.,anal.
6SN1
118
0BK1
10A
A0
2ax
is, s
tand
ard
inte
rface
Mai
n sp
indl
e dr
ive c
ontro
l, an
ano d
irect
mea
s. s
yste
m6S
N112
10B
A11
0AA0
Mai
n sp
indl
e dr
ive c
ontro
l, an
adi
r. m
eas.
sys
tem
, TTL
si
gnal
s6S
N112
10B
A12
0AA0
y
Mai
n sp
indl
e dr
ive c
ontr.
, anal.
ext
erna
l pos
ition
outp
ut6S
N112
10B
A13
0AA0
Indu
ctio
n m
otor
con
trol,
anal
.Fi
xed
setp
oint
s, m
ot. p
ot.
6SN1
122
0BA1
10A
A0
Indu
ctio
n m
otor
con
trol,
anal
anal.
spee
d, fi
xed
setp
., m
ot.p
o
6SN1
122
0BA1
20A
A
Mai
n sp
indl
e dr
ive c
ontro
l, an
al
6SN1
121
0BA1
10A
A1
Indu
ctio
n m
otor
con
trol,
anal
og
6SN1
122
0BA1
10A
A1
Parameter board, feeddrive, analog userfriendly6SN11140AA010AA0
necessary _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____
Main spindle option, feeddrive, analog, userfriendly
6SN11140AA020AA
possible _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____
8A inverter module
6SN1121AA00HA
FD:4/8A
FD:4/8A
_____ FDR:3/6A
_____ _____ _____ _____ IM:3/3/3 A
IM:3/3/3 A
_____ IM:3/3/3 A
15A inverter module
6SN1121AA00AAFD:7.5/15A
FD:7.5/15A
_____ FDR:5/10A
_____ _____ _____ _____ IM:5/5/8 A
IM:5/5/8 A
_____ IM:5/5/8 A
25A inverter module
6SN1121AA00BA
FD:12.5/25A
FD:12.5/25A
_____ FDR:9/18A
_____ _____ _____ _____ IM:8/10/16A
IM:8/10/16A
_____ IM:8/10/16A
50A inverter module
6SN1121AA00CA
FD:25/50A
FD:25/50A
_____ FDR:18/36A
_____ MSD:24/32/32A
MSD:24/32/32A
MSD:24/32/32A
IM:24/32/32A
IM:24/32/32A
MSD:24/32/32A
IM:24/32/32A
80A inverter module
6SN1121AA00DAFD:40/80A
FD:40/80A
_____ FDR:28/56A
_____ MSD:30/40/51A
MSD:30/40/51A
MSD:30/40/51A
IM:30/40/51A
IM:30/40/51A
MSD:30/40/51A
IM:30/40/51A
120A inverter module
6SN1121AA00GA
_____ _____ _____ _____ _____ MSD:45/60/76A
MSD:45/60/76A
MSD:45/60/76A
IM:45/60/76A
IM:45/60/76A
MSD:45/60/76A
IM:45/60/76A
108A inverter module
6SN1121AA00LA_____ _____ _____ _____ _____ MSD:
45/60/76AMSD:45/60/76A
MSD:45/60/76A
IM:45/60/76A
IM:45/60/76A
MSD:45/60/76A
IM:45/60/76A
160A inverter module
6SN1121AA00EAFD:80/160A
FD:80/160A
_____ _____ _____ MSD:60/80/102A
MSD:60/80/102A
MSD:60/80/102A
IM:60/80/102A
IM:60/80/102A
MSD:60/80/102A
IM:60/80/102A
200A inverter module
6SN1121AA00FA
FD:100/200A
FD:100/200A
_____ _____ _____ MSD:85/111/127A
MSD:85/111/127A
MSD:85/111/127A
IM:85/111/127A
IM:85/111/127A
MSD:85/111/127A
IM:85/111/127A
04.97General (AL)
1 Permissible combinations of inverter modules and control modules
1
AL
Vorschub/Hauptspindelregelungen mit analoger Sollwertschnittstelle
07.94
AL/1-4 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-1 Selection table to set the current controller referred to the resulting inverter currents
SIMODRIVE 611 components
Indu
ctio
n m
otor
con
trol,
anal
og
Mai
n sp
indl
e dr
ive c
ontro
l, an
al
6SN1
122
0BA1
10A
A1
Indu
ctio
n m
otor
con
trol,
anal
6SN1
121
0BA1
10A
A1
anal.
spee
d, fi
xed
setp
., m
ot.p
ot.
Indu
ctio
n m
otor
con
trol,
anal
.
6SN1
122
0BA1
20A
A
Fixe
d se
tpoi
nts,
mot
. pot
.
Mai
n sp
indl
e dr
ive c
ontr.
, anal.
6SN1
122
0BA1
10A
A0
ext
erna
l pos
ition
outp
ut
Mai
n sp
indl
e dr
ive c
ontro
l, an
al
6SN1
121
0BA1
30A
A0
dir.
meas.
sys
tem
, TTL
si
gnal
s
Mai
n sp
indl
e dr
ive c
ontro
l, an
al
6SN1
121
0BA1
20A
A0y
no d
irect
mea
s. s
yste
m
Feed
driv
e re
solve
r con
tr.,anal.
6SN1
121
0BA1
10A
A0
Feed
driv
e re
solve
r con
tr.,anal.
6SN1
118
0BK1
10A
A0
Feed
driv
e co
ntro
l, an
alog
2ax
is, s
tand
ard
inte
rface
6SN1
118
0BJ1
10A
A0
Feed
driv
e co
ntro
l, an
alog
1ax
is, s
tand
ard
inte
rface
2ax
is, s
tand
ard
inte
rface
Feed
driv
e co
ntro
l, an
alog
6SN1
118
0AE1
10A
A0
1ax
is, s
tand
ard
inte
rface
1ax
is, u
ser
frien
dly
inte
rface
6SN1
118
0AD1
10A
A0
6SN1
118
0AA1
10A
A0
200A inverter modulepipe connection
6SN1121AA00FA
FD:100/200A
FD:100/200A
_____ _____ _____ MSD:85/110/127A
MSD:85/110/127A
MSD:85/110/127A
IM:85/110/127A
IM:85/110/127A
IM:85/110/127A
IM:85/110/127A
300A inverter module
6SN1121AA00JA_____ _____ _____ _____ _____ MSD:
120/150/193A
MSD:120/150/193A
MSD:120/150/193A
IM:120/150/193A
IM:120/150/193A
IM:120/150/193A
IM:120/150/193A
400A inverter module
6SN1121AA00KA0
_____ _____ _____ _____ _____ MSD:200/250/257A
MSD:200/250/257A
MSD:200/250/257A
IM:200/250/257A
IM:200/250/257A
IM:200/250/257A
IM:200/250/257A
2x8A inverter module
6SN1121AB00HA0
_____ _____ FD:2x4/8A
_____ FDR:2x3/6A
_____ _____ _____ _____ _____ _____ _____
2x15A inverter module
6SN1121AB00AA0_____ _____ FD:
2x7.5/15A_____ FDR:
2x5/10A_____ _____ _____ _____ _____ _____ _____
2x25A inverter module
6SN1121AB00BA
_____ _____ FD:2x12.5/25A
_____ FDR:2x9/18A
_____ _____ _____ _____ _____ _____ _____
2x50A inverter module
6SN1121AB00CA_____ _____ FD:
2x25/50A_____ FDR:
2x18/36A_____ _____ _____ _____ _____ _____ _____
This StartUp Guide is valid for the following drive modules:
6SN11301AA110A0 1axis feed drive module, userfriendly interface6SN11301AA120A0 1axis feed drive module, userfriendly interface
with main spindle drive option
6SN11301AD110A0 1axis feed drive module, standard interface6SN11301AE110A0 2axis feed drive module, standard interface6SN11351BA10A0 MSD module6SN11401BA10A0 IM module
04.97General (AL)1 Permissible combinations of inverter modules and control modules
AL
07.94
AL/1-5 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Note
The document describes all of the steps necessary to commission an installedSIMODRIVE drive group. Please refer to the associated Planning Guides foradditional technical information, e.g. regarding
ambient conditions
recommended circuits
connecting diagrams
dimension sheets/dimension drawings
Please refer to the associate Planning Guide:SIMODRIVE 611Transistor PWM Inverters for AC Feed Drives and AC Main Spindle DrivesOrder No.: 6SN11970AA000PSIMODRIVEAC Motors for Feed and Main Spindle DrivesOrder No.: 6SN11970AA200P
04.97General (AL)
1 Permissible combinations of inverter modules and control modules
AL
07.94
AL/1-6 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
04.97General (AL)1 Permissible combinations of inverter modules and control modules
NE
NEi Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Supply infeed (NE)
1 Standard settings, NE modules (UE and I/R modules), monitoring andpulsed resistor modules NE/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Maintenance and diagnostics NE/2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Terminals and relay functions NE/2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Appendix NE/3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Connecting terminals NE, monitoring and pulsed resistor modules NE/3-12. . 3.2 Connecting terminals, UE module 5/10 kW NE/3-14. . . . . . . . . . . . . . . . . . . . . .
NE
07.94
NEii Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
NE
07.94
NE/1-3 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Standard settings, NE modules (UE andI/R modules), monitoring and pulsed resi-stor modules
! WichtigObserve the information for sinusoidal current control for I/R modules!
A switch S1 is provided on the upper side of the NE and monitoring module to set the fol-lowing functions:
Sinusoidal current control
ON: OFF:
Vsupply=415V10% VDClink=625 V1)
Fault messageRegen. feedback off1)
Vsupply=415V10% VDC link=600 V1)
Regenerative feedback on
1
2
34VSupply=480V+6%10%
Ready signal
S1
Controlled infeed off Control infeed56
Standard, refer to S1.1
Squarewave current control
Standard setting
Fig. 1-1 DIL switch S1
! WichtigFor I/R modules Order No. 6SN1141001 the basic setting is forsinusoidal control (closedloop). Observe the information/instructions, PageNE13!
! WichtigBefore the equipment is poweredup or down using the main switch or a line contactor,terminal 63 (pulse enable) and/or terminal 48 (start terminal, contactor control) should bedeenergized or disconnected!
1) Only possible for I/R modules, monitoring thresholds are increased for all NE modules
Supply infeed (NE)1 Standard settings, NE modules, monitoring and pulsed resistor modules04.97
1
NE
07.94
NE/1-4 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
OFF: I/R module Vsupply =400V10%; VDC link=600VUE module Vsupply =400V10%; VDC link=1.35*Vsupplymonitoring thresholds: (I/R, UE, monitoring modules)pulsed resistor on =644V; pulsed resistor off =618VVDC link>> =710V;
ON: I/R module Vsupply =415V10%; VDC link=625VUE module Vsupply =415V10%; VDC link=1.35*VsupplyMonitoring thresholds: (I/R, UE, monitoring modules)pulsed resistor on =670V; pulsed resistor off =640VVDC link>> =740V;
OFF: Ready signal (X111 ready relay)For S1.2=OFF, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminals NS1NS2 connected,
terminal 48 enabled)
terminal 63,64=ENERGIZED no fault present (also not on feed drive 611A Standard, or 611D drives) feed drive with standard interface or resolver for setting Ready is enabled (terminals 663,65)
ON: Fault message (X111 ready relay)For S1.2=ON, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminals NS1NS2 connected,
terminal 48 enabled)
no fault present (also not on feed drive 611A Standard, or 611D drives) feed drive with standard interface or resolver for setting ready is enabled (terminals 663,65);
OFF: Standard setting, regenerative feedback activeI/R modules are capable of regenerative feedback UE modules: The pulsed resistor in the module is effective
ON: Regenerative feedback switchedout (disabled)I/R module: Regenerative feedback operation is inhibitedUE modules: The pulsed resistor in the module is not effective
Comment: This function is only effective for UE 10 kW fromMLFB (Order No.): 6SN11461AC000AA1 (however, not for UE
28kW)
OFF: Standard setting for all NE modules, refer to S1.1 ON: Vsupply =480V+6%10%; VDC link=1.35*Vsupply in the infeed direction
Monitoring thresholds: (I/R, UE, monitoring modules)pulsed resistor on =744V; pulsed resistor off =718VVDC link>> =795V.
Comment: Uncontrolled operation in the infeed direction. (only valid for Order No. 6SN1141001
Switch S 1.1 :
Switch S 1.2 :
Switch S 1.3 :
Switch S 1.4 :
Supply infeed (NE)1 Standard settings, NE modules, monitoring and pulsed resistor modules 04.97
NE
07.94
NE/1-5 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Note
Only in conjunction with power modules, Order No. (6SN1141001).For motors with shaft height
NE
07.94
NE/1-6 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Supply infeed (NE)1 Standard settings, NE modules, monitoring and pulsed resistor modules 04.97
NE
07.94
NE/2-7 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Service and diagnostics
Display elements of the monitoring and NE modules
1 2
3 45 6
1 LED, red 15 V electronics power supply faulted2 LED, red 5 V voltage level faulted3 LED green external enable signals not available
(terminal 63 and/or terminal 64 missing)4 LED yellow DC link charged5 LED, red line supply fault (single or multiphase supply failure at the
terminals U1, V1, W1) 1) commutating reactor either not available or incorrectly selected, fault level of the line supply or transformer too low
6 LED red DC link overvoltage possible causes: Regenerative feedback off, settingup operation, line supply fault, for UE pulsedresistor not operational, line supply voltage too high, dynamic overload condition
Effects:1 red LED bright: Pulses for the complete drive group are canceled2 red LED bright: Pulses for the complete drive group are canceled4 yellow LED dark: xxxx5 red LED bright: 1) Only the I/R module pulses are canceled (regenerative feedback
no longer possible. Axes first continue to run. Ready relay dropsout6 red LED bright: Pulses for the complete drive group are canceled
1) Line supply fault identification time approx. 30msLine supply fault is identified for a threephase voltage < 280V.For 1phase supply failure, the drive axes pulses are canceled after approx. 1 min.(latched signal) valid for Order No. 6SN11141001
Supply infeed (NE)04.97 2 Service and diagnostics
2
NE
07.94
NE/2-8 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
2.1 Terminals and relay functions X111: READY RELAY:
terminals 72 73.1: NO contact in the quiescent state terminals 73.2 74: NC contact in the quiescent state
For S1.2=OFF, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminals NS1NS2 connected, terminal 48 enabled) terminals 63, 64 =ENERGIZED no fault present (also not on feed drive 611A Standard, or 611D drives) feed drive with Standard interface or resolver is enabled for the ready setting (terminals663, 65)For S1.2=ON, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminal NS1NS2 connected, terminal 48 enabled) no fault present (also not on feed drive 611A Standard, and 611D drives) feed drive with Standard interface or resolver enabled for this ready setting (terminals 663, 65).
X121: I2t_alarm and motor overtemperature:terminal 5.1 5.2: NO contact in the quiescent stateterminal 5.1 5.3: NC contact in the quiescent stateThis relay switches, if: the > heatsink temperature monitoring responds at the I/R the > motor temperature monitoring responds at the 611D feed drive
> heatsink temperature monitoring responds at the feed drive 611A userfriendly
> motor temperature monitoring responds> heatsink temperature monitoring responds> I2ttemperature monitoring responds (nonlatching)
at 611A Standard > Motor temperature monitoring responds> heatsink temperature monitoring responds
X171: Terminal NS1NS2 (coil circuit of the internal line supply and precharging contac-tor): is used to electrically isolate from the line supply (signal contact, terminals 111213 must be interrogated) may only be switched if terminal 48 is opencircuit (without any restriction from Order No. 6SN1141010 for 10, 16 and 55kW, from Order No. 6SN1141020 for 36kW, all 80 and 120kW)
terminal 48: Start has the highest priority Sequence: Precharging ON interrogation VDC link310V and VDC link2*Vsupply50V
> 500ms precharging contactor OUT, interrogation whetherOUT, main contactor IN>1s internal enable signals (for I/R and module group)
saved during precharging
terminal 63: Pulse enable has the highest priority for pulse enable of all the modules acts instantaneously (without delay)
Terminal 64: Drive enable acts instantaneously on all modules when the signal is withdrawn, nset is set to 0 for all drives, and
> for main spindle drive / induction motor module 611 A, the pulses are canceled after a speed, which can be set, is fallen below. The drive is braked along the ramp.
Supply infeed (NE)04.972.1 Terminal and relay functions
NE
07.94
NE/2-9 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
> for feed drives 611 A, after the selected timer stages have expired (as supplied: 240ms) all of the controllers and pulses are inhibited. The drive
brakes along the current limit. > for 611D drives, the pulses are deleted after a selectable speed has been fallen below and/or a time which can be set, has expired. The drive brakes along the set limits. (For spindles, a ramp can be achieved via regenerative limiting [kW])
terminal 112: Settingup operation (Vmin 3ph. 24V AC or 34 V DC) the VDC link closedloop control is inhibited regenerative feedback is not possible, i.e. when braking, VDC link can be >600V! this function is interrogated with the start inhibit signal, terminal AS1AS2.
! CautionFor induction motors, even for low VDC link, high speeds can be reached! terminals AS1AS2: start inhibit signal
terminals AS1AS2 closed means start inhibit is effective (settingup operation) terminals 111, 113, 213: signal contact, internal line contactor
terminals 111 113: NO contact terminals 111 213: NC contact (for I/R 16kW and UE 10kW only from
Order No. 6SN1141010 ) terminal 19: FR:
reference ground, enable voltage floating (connected to the general reference ground, terminal 15 via 10k) it is not permissible to connect terminal 19 with terminal 15 (connect to PE rail or X131)
terminal 9: FR+: 24V enable voltage max. load capability of the power supply:500mA (corresponds to 8 slots;1 optocoupler input
requires 12mA)
X 141: electronic voltages: terminal 7: P24 +20.4 to 28.8V / 50mA terminal 45: P15 +15V / 10mA terminal 44: N15 15V / 10mA terminal 10: N24 20.4 to 28.8V / 50mA terminal 15: M 0V it is not permissible to connect terminal 15 to PE (ground loop) it is not permissible to connect terminal 15 with terminal 19
(shortcircuit via reactor, which internally connects terminal 15 with X131)
terminal L1L2 for 80kW and 120kW I/R is used to supply the coil of the internal line contactor is supplied directly at the line supply with 2ph. 400V AC (not between I/R and reactor) fuse: IN 4 A, type gL
Fan connection for 80 and 120kW I/R 3ph. 360 to 510V AC , 4565 Hz directly at the line supply (not between the I/R and reactor) observe the rotating field (phase sequence)! fuse: IN 1.5 A (motor protection circuitbreaker)
Supply infeed (NE)04.97 2.1 Terminal and relay functions
NE
07.94
NE/2-10 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
6 conductor connection with additional connection of the power supply at the DClink: for this operating mode, terminals 2U1, 2V1 and 2W1 of the power supply must be supplied with the line supply voltage between the series reactor and I/R, otherwise the power supply will be destroyed! This is also valid for the monitoring modules!
Monitoring module with line supply connection and additional connection of the power sup-ply to the DC link: for this operating mode, terminals 2U1, 2V1 and 2W1 of the power supply must be supplied with the line supply voltage between the series reactor and I/R, as otherwise the power supply will be destroyed. terminal 63 must be switched via the ready relay of the I/R in order to prevent the module, to the right of the monitoring module, starting during precharging.
If a line supply fault is displayed or if the yellow LED is dark, the overvoltage limiting modulemust be checked. Procedure:
1. Powerdown the drive converter (into a novoltage condition)2. Remove the overvoltage limiting module and insert connector X181 on the NE module.
If the NE module functions, then the overvoltage limiting module is defect and must bereplaced. Otherwise, check the line supply and if required, also the NE module/drive group.
Note
In this way, operation can be continued, but without overvoltage protection.
3. Insert the overvoltage limiting module 566018.9415.00 up to its end stop, and insertconnector X181 on the overvoltage limiting module.
Diagnostic instruc-tions
Supply infeed (NE)04.972.1 Terminal and relay functions
NE
07.94
NE/3-11 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Appendix
Note
When using nonPELV circuits at terminals AS1, AS2, terminal 111, terminal 113, terminal213, connector coding must be used to prevent the connector being interchanged (referto EN 602041 Section 6.4) refer to Catalog NC 60.1 for the Order No. of the coding con-nector. Only PELV circuits may be connected at terminal 19.
Supply infeed (NE)3.1 Connecting terminals NE, monitoring and pulsed resistor modules
3
NE
07.94
NE/3-12 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
3.1 Connecting terminals NE, monitoring and pulsedresistor modules
Table 3-1 Terminal functions
Term.No.
Desi-gna-tion
FunctionTyp
e1)
Typ. voltage/limit values Max. crosssec-tionTerminals availa-
ble in 3)
U1V1
W1
Supply I 3ph. 400 V AC Refer to the Plan-ning Guide I/R, UE
L1L2
Supply connection for contactor
II
2ph. 400 V AC dir. at supplyL1, L2, L3, refer to Sec. 9.2
16mm2/10mm2 4)16mm2/10mm2 4)
I/R 80/104 kW,120/156 kW
PEP600M600
Protective conductorDC link DC link
II/OI/O
0 V+300 V300 V
BoltBusbarBusbar
I/R, UE, MM, PR
Grounding bar5) I/O 300 V Busbar I/R, UE
P600M600
DC linkDC link
II
+300 V300 V
16mm2/10mm2 4)16mm2/10mm2 4) MM
1R,2R,3R
Internal resistor con-nection
I/O 300 V 16mm2/10mm2 4)PR
X131 Electronics M I/O 0 V 16mm2/10mm2 4) I/R, UE, MMX351 Equipment bus I/O Various Ribbon cable I/R, UE, MM, PR
M500
P500
1U12U11V12V11W12W1
X181
X181
X181X181X181X181X181X181
DC link power supplyDC link power supplyOutput L1Input L1Output L2Input L2Output L3Input L3
I
I
OIOIOI
600 V DC
600 V DC
3ph. 400 V AC 3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC
1.5 mm2
1.5 mm2
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
I/R, UE, MM
745441015R
X141X141X141X141X141X141
P24P15N15N24MRESET6)
OOOOOI
+20.4...28.8 V/50 mA+15 V/10 mA15 V/10 mA20.4...28.8 V/50 mA0 VTerm.15/RE = 10 k
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
I/R, UE, MM
5.35.25.16399
6419
X121X121X121X121X121X121X121
Relay contactsGroup messageI2t/motor temp.
Pulse enable2)Enable voltage2)8)Enable voltage2)8)Drive enable2)Enable voltage, refe-rence potential
NCNO
IIAAI
50 V DC/0.5 A/12 VA max5 V DC/3 mA min
+13 V...30 V/RE = 1.5 k+24 V+24 V+13 V...30 V/RE = 1.5 k0 V
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
I/R, UE, MM
Supply infeed (NE)3.1 Connecting terminals NE, monitoring and pulsed resistor modules 04.97
NE
07.94
NE/3-13 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 3-1 Terminal functions
Term.No.
Terminals availa-ble in 3)
Max. crosssec-tionTyp. voltage/limit values
Type1)
FunctionDesi-gna-tion
74nc
73.273.1
nc72
X111X111X111X111X111X111
Relay contactReady signal
NC
II
NO
1ph. 250V AC/50V DC/2A max5V DC/3mA min
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
I/R, UE, MM
9112
X161X161
Enable voltage2)8)Settingup operation/Standard operation2)
OI
+24 V+21 V...30 V/RE = 1.5 k
1.5 mm21.5 mm2 I/R, UE, MM
48111213
113
X161X161X161
X161
Contactor control 2)
Signaling contacts
Line contactor
II
NC7)
NO
+13 V...30 V/RE = 1.5 k+30 V/1 A (111113)1ph. 250 V AC/50 V DC/2 A max17 V DC/3 mA min
1.5 mm21.5 mm21.5 mm2
1.5 mm2I/R, UE
AS1AS2
X172X172
Signaling contactStart inhibit (termi-nal112)
INC
250V AC/1A/50V DC/2A max5 V DC/10 mA min
1.5 mm21.5 mm2 I/R
NS1NS2
X171X171
Coil contact for line,precharging contac-tor
OI
+24 V 1.5 mm21.5 mm2 I/R, UE
19
50
X221
X221
Enable voltageReference potentialControl contact for fastdischarge
O
I
0 V
0 V
1.5 mm2
1.5 mm2 PR
1) I = Input, O = Output, NC = NC contact, NO = NO contact (for signal: Closed= high/open= low)2) Terminal 19 is the reference ground (is connected inside the module with 10 k to the general reference groundX131/terminal 15). It is not
permissible to connect terminal 15 to PE or to terminal 19. Donot connect external voltage sources to terminal 15! Termi-nal 19 can be
connected with X131.3) I/R = infeed/regenerative feedback module;
UE = uncontrolled infeed; monitoring module; PW = pulsedresistor module
4) The 1st number is valid for cable lugs. The second number is valid for finelystranded conductors without connector sleeves.
5) The grounding bar is used to ground the DC link M bus via 100 k (it should preferably always be inserted for nongrounded supply networks).
6) RESET = resets the fault memory, edge triggered for the complete drive group (terminal R terminal 15 = RESET)7) terminal 111213 positivelydriven NC contact (for I/R 16 kW and UE 10kW, only from MLFB (Order No.6SN1141010).
Terminal 111113, NO contact, not positively driven8) max. current load of terminals 919: 0.5A
Supply infeed (NE)3.1 Connecting terminals NE, monitoring and pulsed resistor modules04.97
NE
07.94
NE/3-14 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
3.2 Connecting terminals, UE module 5/10 kW
Table 3-2 Terminal functions
Term.No.
Desi-gnation Function
Type1) Typ. voltage/limit values Max. crosssection
U1V1
W1
X1 Supply I 3ph. 400 V AC 4 mm2 finely strandedwithout connector sleeves
6 mm2 with cable lug
PE1PE2
X131X351
Protective conductor
Electronics MEquipment busGrounding bar3)
I
II/OI/O
0 V
0 VVarious300 V
M5 thread
M4 thread34pin ribbon cable
Busbar
P600M600
DC linkDC link
I/OI/O
+300 V300 V
BusbarBusbar
M500P5001U12U11V12V11W12W1
X181X181X181X181X181X181X181X181
DC link power supplyDC link power supplyOutput L1Input L1Output L2Input L2Output L3Input L3
IIOIOIOI
300 V+300 V3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
5.35.25.1nc
X121AX121AX121AX121A
Relay contactGroup signalI2t/motor temperature
NCNO
I
50 V DC/0.5 A/12 VA max5 V DC/3 mA min
1.5 mm21.5 mm21.5 mm21.5 mm2
7473.273.1
72
X121BX121BX121BX121B
Relay signalReady/fault
NCII
NO
1ph. 250 V AC/50 V DC/2 Amax
5 V DC/3 mA min
1.5 mm21.5 mm21.5 mm21.5 mm2
6399
64R
19
X141AX141AX141AX141AX141AX141A
Pulse enable2)FR+2)4)FR+2)4)Drive enable2)RESET2)FR, reference ground, enablevoltage
IOOIIO
+13 V...30 V/RE = 1.5 k+24 V+24 V+13 V...30 V/RE = 1.5 k0/+24 V0 V
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
111213
X161X161
Signaling contactLine contactor
INC
1ph. 250 V AC/50 V DC/2 A17 V DC/3 mA min
1.5 mm21.5 mm2
911248
NS1NS2
15
X141BX141BX141BX141BX141BX141B
FR+2)4)Settingup/standard operation2)Contactor control2)
M
Coil contact for the line supply precharging contactor
OIIOIO
+24 V+13 V...30 V/RE = 1.5 k+13 V...30 V/RE = 1.5 k+24 V0/+24 V0 V
1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2
1) I = Input, O = Output, NC = NC contact, NO = NO contact (for signal: Closed= high/open= low)2) Terminal 19 is the reference terminal (connected in the module to general reference ground X131
with 10 k).3) The grounding bar is used to ground the DC link M bar via 100 k (this should always be
inserted for nongrounded supply networks).4) max. current loading of terminals 9 19: A1
Supply infeed (NE)04.973.2 Connecting terminals, UE module 5/10 kW
VS
VSi Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Feed modules (VS)
1 Short startup, standard settings VS/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Tachometer adaptation for motors with tachometer voltages 3
16.5 V at rated speed VS/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Current controller settings VS/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Speed controller optimization VS/2-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Tachometer adjustment VS/2-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Setting the proportional gain Kp without adaptation VS/2-18. . . . . . . . . . . . . . . 2.3 Setting the integral action time TN without adaptation VS/2-19. . . . . . . . . . . . . 2.4 Integral action time with adaptation (if required) VS/2-20. . . . . . . . . . . . . . . . . . 2.5 Proportional gain with adaptation (only userfriendly interface) VS/2-21. . . . . 2.6 Setting the adaptation range (generally not required) VS/2-22. . . . . . . . . . . . . . 2.7 I component limiting of the speed controller VS/2-22. . . . . . . . . . . . . . . . . . . . . . 2.8 Drift offset VS/2-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Startup, supplementary functions VS/3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Setting elements with standard interface VS/3-25. . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 Dimensioning the setting elements (standard interface) VS/3-26. . . . . . . . . . . . 3.2 Setting elements with userfriendly interface VS/3-29. . . . . . . . . . . . . . . . . . . . .
4 Setpoint interfaces VS/4-33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Startup with main spindle drive option VS/5-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Presettings VS/5-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.1 Settings with the control board removed VS/5-35. . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2 Settings in operation VS/5-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Analog outputs VS/5-40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Free for supplementary texts VS/6-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Poweron VS/7-43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Maintenance and diagnostics VS/8-45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.1 Test sockets and display elements of the feed modules VS/8-45. . . . . . . . . . . . 8.1.1 Userfriendly interface VS/8-45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1.2 Standard interface VS/8-47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 Troubleshooting VS/8-48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VS
07.94
VSii Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
9 Appendix VS/9-49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 Connecting terminals VS/9-49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2 Block diagram, MSD option board VS/9-52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.3 Block diagram, parameter board VS/9-53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4 Block diagram, standard interface VS/9-54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Startup is subdivided into steps; after the standard setting, this can be follo-wed by an additional startup step or the drive converter poweredup.
Short startupStandard settings
Speed controller op-timization
Supplementary functions
Setpointinterfaces
Startup with mainspind. drive option
Power.up, Sect. 7
Service anddiagnostics
Appendix
Sect. 1
Sect. 2
Sect. 3
Sect. 4
Sect. 5
Sect. 8
Sect. 9
Startup steps of thefeed drive moduleswith userfriendlyand standard interface
12.94
VS
07.94
VS/1-3 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Short startup, standard settings
The setting elements for the userfriendly interface are located on the parame-ter board, for the standard interface, on the control (refer to Section 9 Appen-dix). The tachometer adaptation, current normalization and current controllergain parameters should be set for a standard startup.
1.1 Tachometer adaptation for motors with tachometer vol-tages 16.5 V at rated speed
Only for 1FT503AF71 and 1FT504AF71 motors
All three contacts, switch S1 (S4 for the 2nd axis standard interface) = ONFurther, an adjustment can be made using discrete resistors, refer to Section 3.1 - 3.2.
1.2 Current controller settingsThe settings for the current limit and current controller gain Kp(I) can be takenfrom the adaptation tables, Table 1-3 up to Table 1-9. If the required feed mo-dule/motor combination cannot be found, the values can be determined usingthe associated formulas.
Parameter board, switch S2
Control board, switch S2 (S5 for 2nd axis)
Note
The following setting values are valid for both control versions, as long as, inindividual cases, specific reference is not made to differences.
Userfriendly andstandard interface
Userfriendly inter-face
Standard interface
Feed modules (VS)1 Short startup, standard settings04.97
1
VS
07.94
VS/1-4 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Current limit Imax (adjusted maximum current)Ilimit (peak current of the power module)
[%]=
Table 1-1 Current limit
S2.xor
S5.xto ON
2 3 23
4 24
34
234
5 25
35
235
45
345
2345
(%) 100 85 68 61 50 46 41 39 36 34 30 29 26 24 23
The current limit must be reduced at least to the peak value permitted for themotor. It may be necessary to reduce it still further depending on the mechanicalsystem which is driven.
Imax =maximum axis current set in ALA =motor winding inductance in mH (refer to the configuringguide, AC
motors for feed and main spindledrives)
Imax LA40
Kp(I) t
Table 1-2 Current controller gain
S2.xandS5.xto ON
6 7 67
8 68
78
9 69
79
679
89
789
6789
Kp(I) 0.5 1 2 2.5 4 4.5 5.5 6 6.5 7.5 8 9.5 11 11.5
The setting range of the current controller gain can be additionally increasedusing R15 on the parameter board.The following formula is valid for S2.6 to S2.9 closed (ON):
Kp(I) 11, 5 1230 R15
Current actual va-lue normalization
Current controllergain Kp(I)
Userfriendly inter-face
Feed modules (VS)04.971.2 Current controller settings
VS
07.94
VS/1-5 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Definition: o = Contact in the basic OFF settingx = Contact in the ON setting
Table 1-3 Adaptation table for feed module 4/8 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5034AK71 0.5 0.93 6000 x o x o 3.68 o x o o 2.0
5036AK71 0.75 1.4 6000 o x o o 5.44 o x o o 2.0
5042AF715042AK71
0.660.66
0.751.2
30006000
xx
ox
oo
xo
2.724.88
xx
xx
oo
oo
2.52.5
5044AF715044AK71
1.31.3
1.52.3
30006000
oo
xo
oo
oo
5.448.0
xx
xo
oo
oo
2.51.0
5046AF71 2.6 3.0 3000 o o o o 8.0 o x o o 2.0
5062AC715062AF715062AG715062AK71
2.22.22.22.2
1.32.02.73.9
2000300040006000
oooo
xooo
oooo
oooo
5.448.08.08.0
xoox
xxoo
xoxo
xxoo
11.57.54.01.0
5064AC71 4.5 2.7 2000 o o o o 8.0 o x o x 7.55066AC71 6.5 3.9 2000 o o o o 8.0 x o x o 4.55070AC715070AF715070AG71
3.03.03.0
1.82.63.6
200030004000
ooo
ooo
ooo
ooo
8.08.08.0
xox
xxo
xox
xxo
11.57.54.5
5071AC71 4.5 2.9 2000 o o o o 8.0 x x o x 8.0
1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
Adaptation tables
Feed modules (VS)04.97 1.2 Current controller settings03.96
VS
07.94
VS/1-6 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-4 Adaptation table for feed module 7.5/15 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5034AK71 0.5 0.93 6000 o x x x 3.68 o x o o 2.0
5036AK71 0.75 1.4 6000 o o o x 5.44 o x o o 2.0
5042AF715042AK71
0.660.66
0.751.2
30006000
xx
xx
xo
xx
3.454.5
oo
ox
xo
oo
4.02.0
5044AF715044AK71
1.31.3
1.52.3
30006000
xx
xx
xo
oo
5.859.15
oo
ox
xo
oo
4.02.0
5046AF715046AK71
2.62.6
3.04.7
30006000
xo
oo
oo
oo
12.715.0
ox
oo
xo
oo
4.01.0
5062AC715062AF715062AG715062AK71
2.22.22.22.2
1.32.02.73.9
2000300040006000
xooo
ooxo
oxoo
xooo
5.17.510.215.0
oxox
xoxx
xoxo
xxoo
11.06.55.52.5
5064AC715064AF715064AG71
4.54.54.5
2.74.15.5
200030004000
ooo
xoo
ooo
ooo
10.215.015.0
oxx
oox
xoo
xxo
9.56.52.5
5066AC715066AF71
6.56.5
3.96.0
20003000
oo
oo
oo
oo
15.015.0
oo
oo
xx
xo
9.54.0
5070AC715070AF715070AG715070AK71
3.03.03.03.0
1.82.63.65.3
2000300040006000
oooo
oxoo
xooo
oooo
7.510.215.015.0
xoxo
xoxo
xxox
xxxo
11.59.58.04.0
5071AC715071AF715071AG71
4.54.54.5
2.94.35.2
200030004000
xoo
ooo
ooo
ooo
12.715.015.0
xxx
xoo
xox
xxo
11.56.54.5
5072AC71 10.0 6.1 2000 o o o o 15.0 x x o x 8.05073AC715073AF71
7.07.0
4.36.4
20003000
oo
oo
oo
oo
15.015.0
oo
oo
xx
xo
9.54.0
5100AC71 10.0 6.2 2000 o o o o 15.0 o x x o 5.5
1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
Feed modules (VS)04.971.2 Current controller settings 03.96
VS
07.94
VS/1-7 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-5 Adaptation table for feed module 12.5/25 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5036AK71 0.75 1.4 6000 x x x x 5.75 o x o o 2.0
5044AF715044AK71
1.31.3
1.52.3
30006000
oo
xo
xo
xx
6.09.0
oo
ox
xo
oo
4.02.0
5046AF715046AK71
2.62.6
3.04.7
30006000
oo
ox
xo
oo
12.517.0
oo
ox
xo
oo
4.02.0
5062AC715062AF715062AG715062AK71
2.22.22.22.2
1.32.02.73.9
2000300040006000
xxxx
xoox
xoxo
xxoo
5.758.5
10.2515.75
xxox
xxxx
xoxo
xxoo
11.58.05.52.5
5064AC715064AF715064AG715064AK71
4.54.54.54.5
2.74.15.58.0
2000300040006000
xooo
oxoo
xooo
oooo
10.2517.025.025.0
xxox
xoxx
xoxo
xxoo
11.56.55.52.5
5066AC715066AF715066AG715066AK71
6.56.56.56.5
3.96.07.911.6
2000300040006000
oooo
xooo
oooo
oooo
17.025.025.025.0
oxxo
ooxx
xooo
xxoo
9.56.52.52.0
5070AC715070AF715070AG715070AK71
3.03.03.03.0
1.82.63.65.3
2000300040006000
oxoo
xoxo
oxoo
xooo
7.511.517.025.0
xoox
xxoo
xxxo
xxxx
11.511.09.56.5
5071AC715071AF715071AG715071AK71
4.54.54.54.5
2.94.35.27.9
2000300040006000
oooo
oxoo
xooo
oooo
12.517.025.025.0
xxxx
xxxx
xooo
xxxo
11.58.08.02.5
5072AC715072AF715072AG71
10.010.010.0
6.19.112.0
200030004000
ooo
ooo
ooo
ooo
25.025.025.0
xox
xox
xoo
xxo
11.56.02.5
5073AC715073AF715073AG715073AK71
7.07.07.07.0
4.36.48.112.5
2000300040006000
oooo
xooo
oooo
oooo
17.025.025.025.0
oxxx
oooo
xoxo
xxoo
9.56.54.51.0
5074AC71 14.0 8.5 2000 o o o o 25.0 x x o x 8.05076AC71 18.0 11.5 2000 o o o o 25.0 o x x o 5.55100AC715100AF715100AG71
10.010.010.0
6.29.212.5
200030004000
ooo
ooo
ooo
ooo
25.025.025.0
oox
oox
xxo
xoo
9.54.02.5
5101AC71 15.0 9.4 2000 o o o o 25.0 o x x o 5.55102AA71 27.0 9.9 1200 o o o o 25.0 x x o x 8.0
5103AC71 19.0 12.0 2000 o o o o 25.0 o o x o 4.0
1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
Feed modules (VS)04.97 1.2 Current controller settings03.96
VS
07.94
VS/1-8 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-6 Adaptation table for feed module 25/50 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5044AK71 1.3 2.3 6000 o o x x 13.0 x x o o 2.5
5046AF715046AK71
2.62.6
3.04.7
30006000
oo
xo
ox
xo
15.025.0
ox
ox
xo
oo
4.02.5
5062AG715062AK71
2.22.2
2.73.9
40006000
xo
ox
xx
xo
13.019.5
xx
oo
ox
xo
6.54.5
5064AC715064AF715064AG715064AK71
4.54.54.54.5
2.74.15.58.0
2000300040006000
oxoo
oxox
xxxo
xooo
13.019.525.034.0
xxox
xxxx
xoxo
xxoo
11.58.05.52.5
5066AC715066AF715066AG715066AK71
6.56.56.56.5
3.96.07.911.6
2000300040006000
xxoo
xxxo
xooo
oooo
19.530.534.050.0
xxxo
xxoo
xoxx
xxoo
11.58.04.54.0
5070AF715070AG715070AK71
3.03.03.0
2.63.65.3
300040006000
oxo
xoo
xox
xxo
12.017.025.0
xox
xoo
xxo
xxx
11.59.56.5
5071AC715071AF715071AG715071AK71
4.54.54.54.5
2.94.35.27.9
2000300040006000
oooo
oxox
xxxo
xooo
13.020.525.034.0
xoxo
xoxo
xxox
xxxo
11.59.58.04.0
5072AC715072AF715072AG715072AK71
10.010.010.010.0
6.19.112.017.5
2000300040006000
oxoo
oooo
xooo
oooo
25.042.550.050.0
xoxx
xoox
xxoo
xxxo
11.59.56.52.5
5073AC715073AF715073AG715073AK71
7.07.07.07.0
4.36.48.112.5
2000300040006000
oxxo
xxoo
xooo
oooo
20.530.542.550.0
xxox
xxxx
xooo
xxxo
11.58.07.52.5
5074AC715074AF715074AG715074AK71
14.014.014.014.0
8.513.016.525.0
2000300040006000
xooo
oooo
oooo
oooo
42.550.050.050.0
xxxx
xooo
xoxo
xxoo
11.56.54.51.0
5076AC715076AF715076AG71
18.018.018.0
11.516.521.5
200030004000
ooo
ooo
ooo
ooo
50.050.050.0
oxx
xox
xxo
xoo
11.04.52.5
5100AC715100AF715100AG715100AK71
10.010.010.010.0
6.29.212.518.0
2000300040006000
xxoo
xooo
oooo
oooo
30.542.550.050.0
xxxx
xoox
xoxo
xxoo
11.56.54.52.5
5101AC715101AF715101AG71
15.015.015.0
9.414.517.5
200030004000
xoo
ooo
ooo
ooo
42.550.050.0
oxx
oox
xxo
xoo
9.54.52.5
5102AA715102AC715102AF71
27.027.027.0
9.916.525.0
120020003000
xoo
ooo
ooo
ooo
42.550.050.0
xxx
xox
xoo
xxo
11.56.52.5
1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
Feed modules (VS)04.971.2 Current controller settings 03.96
VS
07.94
VS/1-9 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-6 adaptation table for feed module 25/50 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5103AC715103AF715103AG71
19.019.019.0
12.017.523.0
200030004000
ooo
ooo
ooo
ooo
50.050.050.0
xxo
xxx
ooo
oox
8.02.52.0
5104AA715104AC71
37.037.0
14.022.5
12002000
oo
oo
oo
oo
50.050.0
xo
xo
xx
xo
11.54.0
5106AA71 45.0 17.0 1200 o o o o 50.0 x x o x 8.0
5108AA71 55.0 20.5 1200 o o o o 50.0 x o o x 6.5
5132AA71 60.0 22.5 1200 o o o o 50.0 o x o x 7.5
1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
Feed modules (VS)04.97 1.2 Current controller settings03.96
07.94
VS/1-10 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-7 Adaptation table for feed module 40/80 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
4101SK714101SN71
20.020.0
33.039.0
60008000
oo
oo
oo
oo
80.080.0
ox
xo
oo
oo
2.01.0
4102SG71 33.0 35.0 4000 o o o o 80.0 o o x o 4.05046AK71 2.6 4.7 6000 o x o x 24.0 x x o o 2.5
5062AK71 2.2 3.9 6000 o x x x 19.2 o o x o 4.0
5064AF715064AG715064AK71
4.54.54.5
4.15.58.0
300040006000
ooo
xoo
xox
xxo
19.228.840.0
xxo
xoo
oox
xxo
8.06.54.0
5066AC715066AF715066AG715066AK71
6.56.56.56.5
3.96.07.911.6
2000300040006000
oooo
xoox
xoxo
xxoo
19.228.240.054.4
xxox
xxoo
xoox
xxxo
11.58.06.04.5
5070AK71 3.0 5.3 6000 o x o x 24.0 x o o x 6.5
5071AF715071AG715071AK71
4.54.54.5
4.35.27.9
300040006000
oxo
ooo
xox
xxo
20.827.240.0
oxx
oxo
xox
xxo
9.58.04.5
5072AC715072AF715072AG715072AK71
10.010.010.010.0
6.19.112.017.5
2000300040006000
oooo
ooxo
oxoo
xooo
28.840.054.480.0
xooo
xoxx
xxox
xxxo
11.59.57.55.5
5073AC715073AF715073AG715073AK71
7.07.07.07.0
4.36.48.112.5
2000300040006000
oxoo
oxox
xxxo
xooo
20.831.240.054.4
xxxx
xxox
xooo
xxxo
11.58.06.52.5
5074AC715074AF715074AG715074AK715074SG715074SK71
14.014.014.014.016.016.0
8.513.016.525.019.028.0
200030004000600040006000
oooooo
oxoooo
xooooo
oooooo
40.054.480.080.080.080.0
xoxxox
xxoxox
xooooo
xxxoxo
11.57.56.52.56.02.5
5076AC715076AF715076AG715076AK715076SG71
18.018.018.018.020.5
11.516.521.532.024.5
20003000400060004000
xxooo
xoooo
ooooo
ooooo
48.868.080.080.080.0
oxxoo
xooxo
xoxox
xxooo
11.06.54.52.04.0
5100AC715100AF715100AG715100AK71
10.010.010.010.0
6.29.212.518.0
2000300040006000
xooo
xoxo
xxoo
oooo
31.240.054.480.0
xxoo
xoxo
xoxx
xxoo
11.56.55.54.0
5101AC715101AF715101AG715101AK71
15.015.015.015.0
9.414.517.526.5
2000300040006000
oooo
oxoo
xooo
oooo
40.054.480.080.0
xoxo
xxox
oxxo
xooo
8.05.54.52.0
1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settingsFeed modules (VS)
03.96
VS
07.94
VS/1-11 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-7 Adaptation table for feed module 40/80 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5102AA715102AC715102AF715102AG71
27.027.027.027.0
9.916.525.031.5
1200200030004000
oooo
oooo
xooo
oooo
40.080.080.080.0
xoox
xoox
xxxo
xxoo
11.59.54.02.5
5103AC715103AF715103AG71
19.019.019.0
12.017.523.0
200030004000
ooo
xoo
ooo
ooo
54.480.080.0
xox
xox
ooo
xxo
8.06.02.5
5104AA715104AC715104AF71
37.037.037.0
14.022.534.0
120020003000
ooo
xoo
ooo
ooo
54.480.080.0
xxx
xox
xoo
xxo
11.56.52.5
5106AA715106AC71
45.045.0
17.026.8
12002000
oo
oo
oo
oo
80.080.0
xo
xx
xx
xo
11.55.5
5108AA715108AC71
55.055.0
20.532.5
12002000
oo
oo
oo
oo
80.080.0
xx
xo
xx
xo
11.54.5
5132AA715132AC715132SA71
60.060.070.0
22.535.526.0
120020001200
ooo
ooo
ooo
ooo
80.080.080.0
xxx
xox
xxx
xox
11.54.511.5
5134AA715134SA71
75.090.0
28.034.0
12001200
oo
oo
oo
oo
80.080.0
oo
oo
xx
xx
9.59.5
5136AA71 85.0 31.5 1200 o o o o 80.0 o x o x 7.5
5138AA71 105.0 39.0 1200 o o o o 80.0 o o o x 6.0
1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settingsFeed modules (VS)
03.96
VS
07.94
VS/1-12 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-8 Adaptation table for feed module 80/160 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
4101SK714101SN71
20.020.0
33.039.0
60008000
oo
oo
oo
oo
160.0160.0
xx
ox
xo
oo
4.52.5
4102SG714102SK71
33.033.0
35.047.0
40006000
oo
oo
oo
oo
160.0160.0
xx
xo
ox
xo
8.04.5
4104SG714104SK71
45.045.0
46.060.0
40006000
oo
oo
oo
oo
160.0160.0
ox
xx
xo
oo
5.52.5
4106SG71 59.0 56.0 4000 o o o o 160.0 x o x o 4.55064AK71 4.5 8.0 6000 o o x x 41.6 x o x o 4.5
5066AG715066AK71
6.56.5
7.911.6
40006000
oo
xo
xo
xx
38.457.6
ox
oo
ox
xo
6.04.5
5071AK71 4.5 7.9 6000 o x x x 38.4 x o x o 4.5
5072AF715072AG715072AK71
10.010.010.0
9.112.017.5
300040006000
ooo
ooo
xox
xxo
41.657.680.0
oxo
oxx
xox
xxo
9.58.05.5
5073AG715073AK71
7.07.0
8.112.5
40006000
oo
ox
xx
xo
41.665.5
xo
oo
ox
xo
6.54.0
5074AC715074AF715074AG715074AK715074SG715074SK71
14.014.014.014.016.016.0
8.513.016.525.019.028.0
200030004000600040006000
oooxox
oxoxox
xxxoxo
xooooo
41.665.680.097.680.097.0
xxxxox
xxoxxx
xoooxo
xxxooo
11.58.06.52.55.52.5
5076AC715076AF715076AG715076AK715076SG715076SK71
18.018.018.018.020.520.5
11.516.521.532.024.536.0
200030004000600040006000
oxoooo
xoxoxo
oxoooo
xooooo
48.073.6108.8160.0108.8160.0
ooxooo
oxooxo
xooxxx
xxxooo
9.57.56.54.05.54.0
5100AF715100AG715100AK71
10.010.010.0
9.212.518.0
300040006000
xxo
xxo
oxx
xoo
46.462.480.0
xxo
xoo
oox
xxo
8.06.54.0
5101AC715101AF715101AG715101AK71
15.015.015.015.0
9.414.517.526.5
2000300040006000
ooox
oxoo
xxxo
xooo
41.665.680.0136.0
oxxo
oooo
xoxx
xxoo
9.56.54.54.0
5102AA715102AC715102AF715102AG715102SF715102SG71
27.027.027.027.034.034.0
9.916.525.031.531.539.5
120020003000400030004000
xooooo
xoxoxo
oxoooo
xooooo
46.480.0108.8160.0108.8160.0
xoooxx
xoxxoo
xxxxxx
xxoooo
11.59.55.55.54.54.5
5103AC715103AF715103AG71
19.019.019.0
12.017.523.0
200030004000
ooo
oox
oxo
xoo
57.680.0108.8
xox
xoo
oox
xxo
8.06.04.5
1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settingsFeed modules (VS)
03.96
VS
07.94
VS/1-13 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-8 Adaptation table for feed module 80/160 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5104AA715104AC715104AF715104SF71
37.037.037.048.0
14.022.534.044.0
1200200030003000
xooo
xxoo
xooo
oooo
62.4108.8160.0160.0
xoxo
xoox
xxox
xxxo
11.59.56.55.5
5106AA715106AC715106AF715106SF71
45.045.045.057.0
17.026.842.554.0
1200200030003000
oooo
oxoo
xooo
oooo
80.0108.0160.0160.0
xoxo
xxoo
xoxx
xxoo
11.57.54.54.0
5108AA715108AC715108AF71
55.055.055.0
20.532.550.5
120020003000
ooo
ooo
xoo
ooo
80.0160.0160.0
xoo
xoo
xxx
xxo
11.59.54.0
5132AA715132AC715132AF715132SA715132SC715132SF71
60.060.060.070.070.070.0
22.535.547.526.041.055.5
120020003000120020003000
oooooo
xooxoo
oooooo
oooooo
108.8160.0160.0108.8160.0160.0
xxoxxx
xxxxxx
xoxxox
xxoxxo
11.58.05.511.58.05.5
5134AA715134AC715134SA715134SC71
75.075.090.090.0
28.047.034.056.0
1200200012002000
oooo
xoxo
oooo
oooo
108.8160.0108.8160.0
xxxx
xoxo
xoxo
xoxx
11.56.511.56.5
5136AA715136AC715136SA715136SC71
85.085.0110.0110.0
31.547.541.061.5
1200200012002000
xoxo
oooo
oooo
oooo
136.0160.0136.0160.0
xxxx
xoxo
xoxo
xxxo
11.56.511.56.5
5138AA715138SA71
105.0140.0
39.052.0
12001200
oo
oo
oo
oo
160.0160.0
xx
xx
xx
xx
11.511.5
1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settingsFeed modules (VS)
03.96
VS
07.94
VS/1-14 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-9 Adaptation table for feed module 100/200 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
4101SK714101SN71
20.020.0
33.039.0
60008000
ox
xo
oo
oo
136.0170.0
xx
xx
oo
oo
2.52.0
4102SG714102SK71
33.033.0
35.047.0
40006000
xo
oo
oo
oo
170.0200.0
oo
ox
xx
xo
9.55.5
4104SG714104SK71
45.045.0
46.060.0
40006000
oo
oo
oo
oo
200.0200.0
xx
ox
oo
xo
6.52.5
4106SG71 59.0 56.0 4000 o o o o 200.0 o x x o 5.55066AK71 6.5 11.6 6000 o x o x 60.0 x o x o 4.5
5072AG715072AK71
10.010.0
12.017.5
40006000
oo
xx
ox
xo
60.082.0
xo
xx
ox
xo
8.05.5
5073AK71 7.0 12.5 6000 o x o x 60.0 o o x o 4.0
5074AF715074AG715074AK715074SG715074SK71
14.014.014.016.016.0
13.016.525.019.028.0
30004000600040006000
ooooo
xxoxo
oxxxx
xoooo
60.082.0100.082.0100.0
xxxox
xoxox
ooooo
xxoxo
8.06.52.56.02.5
5076AC715076AF715076AG715076AK715076SG715076SK71
18.018.018.018.020.520.5
11.516.521.532.024.536.0
200030004000600040006000
oxoooo
oxoxox
xxxoxo
xooooo
52.078.0100.0136.0100.0136.0
xxoxxx
xxxxox
xoxoxo
xxoooo
11.58.05.52.54.52.5
5100AF715100AG715100AK71
10.010.010.0
9.212.518.0
300040006000
xox
xxo
xox
xxo
46.060.092.0
xox
xoo
oox
xxo
8.06.04.5
5101AC715101AF715101AG715101AK71
15.015.015.015.0
9.414.517.526.5
2000300040006000
xoxo
xxox
xoxo
xxoo
46.060.092.0136.0
oooo
oooo
xoox
xxxo
9.56.06.04.0
5102AA715102AC715102AF715102AG715102SF715102SG71
27.027.027.027.034.034.0
9.916.525.031.531.539.5
120020003000400030004000
xxooxo
xxoxxx
xxxooo
xooooo
46.078.0100.0136.0122.0136.0
xoxxoo
xoooxo
xxxxxx
xxoooo
11.59.54.54.55.54.0
5103AC715103AF715103AG71
19.019.019.0
12.017.523.0
200030004000
oxx
xox
oxo
xoo
60.092.0122.0
oxo
oox
xox
xxo
9.56.55.5
5104AA715104AC715104AF715104SF71
37.037.037.048.0
14.022.534.044.0
1200200030003000
oooo
xoxx
oxoo
xooo
60.0100.0136.0136.0
xxox
xxxo
xoxx
xxoo
11.58.05.54.5
5106AA715106AC715106AF715106SF71
45.045.045.057.0
17.026.842.554.0
1200200030003000
xxoo
xxoo
xooo
oooo
78.0122.0200.0200.0
xxox
xxxo
xoxx
xxoo
11.58.05.54.5
1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settingsFeed modules (VS)
03.96
VS
07.94
VS/1-15 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Table 1-9 Adaptation table for feed module 100/200 A
Servomotor Current limit 1) Current controller gain
1FT M [Nm] I [A] n t d [RPM]Contacts
I [A]Contacts
Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)
5108AA715108AC715108AF71
55.055.055.0
20.532.550.5
120020003000
xoo
oxo
xoo
ooo
92.0136.0200.0
xxx
xxo
xox
xxo
11.58.04.5
5132AA715132AC715132AF715132SA715132SC715132SF71
60.060.060.070.070.070.0
22.535.547.526.041.055.5
120020003000120020003000
oxooxo
oooooo
xooxoo
oooooo
100.0170.0200.0100.0170.0200.0
xoxxox
xooxoo
xxoxxo
xxxxxx
11.59.56.511.59.56.5
5134AA715134AC715134SA715134SC71
75.075.090.090.0
28.047.034.056.0
1200200012002000
xoxo
xoxo
oooo
oooo
122.0200.0122.0200.0
xxxx
xxxx
xoxo
xxxx
11.58.011.58.0
5136AA715136AC715136SA715136SC71
85.085.0110.0110.0
31.547.541.061.5
1200200012002000
oooo
xoxo
oooo
oooo
136.0200.0136.0200.0
xxxx
xxxx
xoxo
xxxx
11.58.011.58.0
5138AA715138SA71
105.0140.0
39.052.0
12001200
xx
oo
oo
oo
170.0170.0
xx
xx
xx
xx
11.511.5
1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settingsFeed modules (VS)
03.96
VS
07.94
VS/1-16 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
1.2 Current controller settingsFeed modules (VS)
VS
07.94
VS/2-17 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Speed controller optimization
The additional smoothing functions in the speed controller loop (damping me-chanical resonance effects) are described in Section 3. Proceed as followswhen optimizing the speed controller:4. Tachometer adjustment5. Gain Kp6. Integral action time TN7. Adaptation TN (if required)8. Icomponent limiting (if required)9. Drift compensation (offset)The unit must be poweredup to optimize the speed controller Sections 2.1, 2.2,2.3 and 2.8. Therefore please refer to Section 7 Poweringup.
The potentiometer scale divisions (in the setting tables) are defined as follows:
8 9/10
76
54
32 0/1
5
123
4
987
6
0
10
The setting shown in the diagram cor-responds to 7 scale divisions.
Feed modules (VS)2 Speed controller optimization
2
VS
07.94
VS/2-18 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
2.1 Tachometer adjustmentFor motors with tachometer voltages 16.5 V, it is necessary to also proceedaccording to Section 1.1.
Potentiometer Setting range
T 0.7 nrated 2.2 nact N 2.2 nrated
0 1 2 3 4 5 6 7 8 910
Tachometer potentiometer (scaled)
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2 nact N/ nact
Fig. 2-1 Tachometer adjustment
Extending the setting range using R3 and R10 (only for the userfriendlyinterface).
Function Component Mountednact N > 0.7 nrated Increase R3 0 (as supplied)nact N < 2.2 nrated Mount R10 Open (as supplied)
2.2 Setting the proportional gain Kp withoutadaptation
The proportional gain Kp of the speed controller can be set using potentiometerKp. The range can be extended if required using the fixed resistor R50 (only forthe userfriendly interface ; R50 = 68 k (as supplied)). The gain, set using the Kp potentiometer is additionally influenced by the settingof potentiometer TN.
Feed modules (VS)2.1 Tachometer adjustment 04.97
VS
07.94
VS/2-19 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
Kp
0 1 2 3 4 5 6 7 8 910
Potentio-meter TN
Center
Lefthandendstop
Righthand endstop
Setting of pot. Kp
0
20
40
60
80
100
120
140
160170
Fig. 2-2 Proportional gain Kp as a function of the Kp and TN potentiometers
2.3 Setting the integral action time TN without adaptation
The speed controller integral action time is set using potentiometer TN; therange can be, if required, extended using C2 (only for the userfriendly inter-face).
TN in ms
Setting of pot. TN
0
10
20
30
4045
0 1 2 3 4 5 6 7 8 9 10
Fig. 2-3 Integral action time TN as a function of potentiometer TN
Feed modules (VS)04.97 2.3 Setting the integral action time TN without adaptation
VS
07.94
VS/2-20 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
2.4 Integral action time with adaptation (if required)Adaptation is activated and preset via R34 (only the userfriendly interface),and S3.5 (S6.5 for a 2nd axis) for the standard interface.
R34 = openR34 = mounted
Adaptation inactive (as supplied)Adaptation operates acc. to the following diagrams
TN
TNadapt
Potentiometer TNR34 + potentiometer ADAPT
nx2 nx1
nxAdaptationineffective
Adaptationfully effective
Transitionrange
Fig. 2-4 Integral action time dependency
nx = nsetp. + nact.
0.9
0.7
0.5
0.3
0.10
TNadapt/TN
R34 = 10 kR34 = 0 or standardinterface
Setting of the ADAPT potentiometer
0 1 2 3 4 5 6 7 8 910
Fig. 2-5 Dependency of adaptation TN
Feed modules (VS)04.972.4 Integral action time with adaptation (if required)
VS
07.94
VS/2-21 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition
2.5 Proportional gain with adap