370
SIMODRIVE 611 Analog System Transistor PWM Inverters for AC Feed Drives and AC Main Spindle Drives Installation and Start–up Guide 04.97 Edition Service Documentation

6sn1123 1aa00 0ca2 Lt Modul 50a Simodrive 611 Siemens Manual (1)

  • Upload
    jesusra

  • View
    840

  • Download
    18

Embed Size (px)

Citation preview

  • SIMODRIVE 611 Analog SystemTransistor PWM Inverters for AC Feed Drives and AC Main Spindle Drives

    Installation and Startup Guide 04.97 Edition

    Service Documentation

  • SIMODRIVE 611 Analog SystemTransistor PWM Inverters forAC Feed Drives andAC Main Spindle Drives

    StartUp Guide

    Service Documentation

    Valid for

    Equipment series 6SN11

    04.97 Edition

    Foreword

    General information AL

    Supply infeed NE

    Feed modules VS

    Feed modules,resolver control VR

    Main spindle modules HS

    Induction motor modules AM

    Spare parts ES

    Complete index

  • User Documentation

    SINUMERIK840D/810D/FMNC

    SINUMERIK

    Overview of SINUMERIK 840D/810D/FMNC Documentation (08.97)

    Brochure Catalog Ordering Info. NC 60.1Technical Info. NC 60.2

    ManualConfiguring (HW) FMNC 810D 840D

    Description ofFunctions Drive Functions

    Description ofFunctions Basic Machine Extended Functions Special Functions

    SINUMERIK SINUMERIK

    611D840D/810D

    SINUMERIK

    840D/810D/FMNC

    SINUMERIK

    840D/810D

    840D/810D/FMNC/611

    SIMODRIVEAccessories

    CatalogAccessories NCZ

    SINUMERIKSIROTEC

    SINUMERIK840D/810DFMNC

    Lists

    SINUMERIK

    840D/810D/FMNC

    Description ofFunctionsOperator InterfaceOP 030

    Installation &Start-up Guide FMNC 810D 840D/611D

    SINUMERIK

    Description ofFunctionsTool Manage-ment

    SINUMERIK

    840D

    Description ofFunctionsDigitizing

    SIMODRIVE

    611D

    SINUMERIK

    SINUMERIK

    840D/810D/FMNC

    Configuring KItMMC100/101 Configuring Syntax Development Kit

    SINUMERIK

    840D/810D/FMNC

    Screen KitMMC100/101SW Update andConfiguration

    SINUMERIK840D/810D/FMNC

    Operators Guide Short Guide Operators Guide

    SINUMERIK840D/810D/FMNC

    SINUMERIK840D/810D/FMNC

    ManualOperatorComponents(HW)

    840D/810D/FMNC

    SIMODRIVE

    SIMODRIVE

    SINUMERIK

    SINUMERIK

    Description ofFunctionsSINUMERIKSafety Integrated

    SIMODRIVE

    SINUMERIK

    840D/810D/FMNC

    SIMODRIVE

    611, MotorsDOC ON CDThe SINUMERIK System

    General Documentation

    Electronic Documentation

    Manufacturer / Service Documentation

    Manufacturer / Service Documentation

    SINUMERIK840D/810D/FMNC

    SINUMERIK840D/810D/FMNC

    User Documentation

    Diagnostics GuideOperators Guide Unit Operator Panel HPU

    AUTOTURN Short Guide Programming (Part 1) Setup (Part 2)

    SINUMERIK840D/810D/FMNC

    ProgrammingGuide Short Guide Fundamentals Advanced Cycles Measuring Cycles

    Description ofFunctions MANUALTURN SHOPMILL

    Description ofFunctionsSynchronousactionsWood, Glass,Ceramics

    810D

    SINUMERIK

    Operators Guide MANUALTURN SHOPMILL

    810D

    Manufacturer / Service Documentation

    SINUMERIK840D/810D

    Description ofFunctionsComputer LInk

    SINUMERIK

    840D/810D

    Description ofFunctionsOperator InterfaceHPU

  • SIMODRIVE documentation

    Edition coding

    Brief details of this edition and previous editions are listed below

    The status of each edition is shown by the code in the Remarks column.

    Status code in the Remarks column:

    A New documentation.. . . . B Unrevised reprint with new Order No.. . . . C Revised edition with new status . . . .

    If factual changes have been made on the page since the last edition, this is indicated by a new edition coding in the header on that page.

    07.94 6SN11970AA600BP0 A10.94 6SN11970AA600BP1 C12.94 6SN11970AA600BP2 C03.96 6SN11970AA600BP3 C04.97 6SN11970AA600BP4 C

    Dieses Buch ist Bestandteil der Dokumentation auf CDROM (DOCONCD)

    09.97 6FC5 1986CA000AG0 (840C Read) C09.97 6FC5 1986CB000AG0 (840C Print) C09.97 6FC5 1986CC000AG0 (840C Net) C

    09.97 6FC5 2984CA000AG0 (840D Read) C09.97 6FC5 2984CB000AG0 (840D Print) C09.97 6FC5 2984CC000AG0 (840D Net) C

    This publication was produced on Interleaf V 5.4

    The reproduction, transmission or use of this document or itscontents is not permitted without express written authority. Offenderswill be liable for damages. All rights, including rights created by patentgrant or registration of a utility model or design, are reserved.

    Siemens AG 1994, 1996, 1997 All Rights reserved.

    Functions may be executable in the control but are not described inthis documentation. No claims can be made on these functions ifincluded with a new shipment or when involved with service.

    We have checked the contents of this document to ensure that theycoincide with the described hardware and software. The informationin this document is regularly checked and necessary corrections areincluded in reprints. We are thankful for any recommendations forimprovement.

    Subject to change without prior notice.

    SiemensAktiengesellschaftOrder No. 6SN11970AA600BP4Printed in the Federal Republic of Germany

    1 Siemens AG 1997 All Rights reserved SIMODRIVE 611A I ll i d S U G id /IAA/ 04 97 Edi i

    3ls

  • 07.94

    ii Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Qualified personalFor the purpose of these Instructions and product labels, a qualified person issomeone who is familiar with the installation, mounting, startup and operationof the equipment and the hazards involved. He or she must have the followingqualifications:

    Trained and authorized to energize, deenergize, clear, ground and tag cir-cuits and equipment in accordance with established safety procedures.

    Trained in the proper care and use of protective equipment in accordancewith established safety procedures.

    Trained in rendering first aid.

    ! DangerThis symbol in the document indicates death, severe personal injury or substantial property damage will result if proper precautions are not taken.

    ! WarningThis symbol appears in the document, if death, severe personal injury or pro-perty damage can result if proper precautions are not taken.

    ! CautionThis symbol appears in the document indicating that minor personal injury ormaterial damage can result if proper precautions are not taken.

    ! WichtigThis symbol appears in the documentation if a particular issue is significant.

    Note

    For the purposes of these Instructions, Note indicates information about theproduct or the respective part of the Instruction Manual which is essential tohighlight.

    Definitions

  • 07.94

    iii Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    ! WarningOperational electrical equipment has parts and components which are at ha-zardous voltage levels.Incorrect handling of these units, i. e. not observing the warning information,can therefore lead to death, severe bodily injury or significant material damage.Only appropriately qualified personal may commission/startup this equipment.This personal must have indepth knowledge regarding all of the warning infor-mation and service measures according to this Manual.Perfect, save and reliable operation of this equipment assumes that it has beenprofessionally transported, stored, mounted and installed as well as carefuloperator control and service.Hazardous axis motion can occur when working with the equipment.

    Note

    When handling cables observe the following

    they must not be damaged

    they must not be strained and

    they must not come into contact with rotating components.

    Note

    It is not permissible to connect SIMODRIVE equipment to a supply system withELCBs (this restriction is permitted according to DIN VDE 0160, Section 6.5).When operational, protection against direct contact is provided in a form to al-low the unit to be used in enclosed electrical equipment rooms (DIN VDE 0558Part 1 / 07.87, Section 5.4.3.2.4).In compliance with DIN VDE 0160 / 05.88, all SIMODRIVE units are subject toa highvoltage test at the time of routine testing. If the electrical equipment ofindustrial tools is subject to a highvoltage test, all connections must be discon-nected so that sensitive electronic components in the SIMODRIVE converterare not damage (permissible according to DIN VDE 0113 / 06.93, Part 1, Sec-tion 20.4).

    ! WarningStartup/commissioning is absolutely prohibited until it has been ensured thatthe machine in which the components described here are to be installed, fulfillsthe regulations/specifications of the Directive 89/392/EWG.

  • 07.94

    iv Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    ! WarningThe information and instructions in all of the documentation supplied and anyother instructions must always be observed to eliminate hazardous situations and damage.

    For special versions of the machines and equipment, the information in theassociated catalogs and quotations applies.

    Further, all of the relevant national, local and plant/systemspecific regulations and specifications must be taken into account.

    All work should be undertaken with the system in a novoltage condition!

    ! WarningBefore commissioning 611D, it should be checked that the encoder cable doesnot have a ground fault.If ground faults occur, for loads which exert a force on the drive, uncontrolledmovement could occur. This no longer occurs for 6SN11180D20AA0, Version B.

  • 07.94

    v Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Electro Static Devices

    Components which can be destroyed by electrostatic discharge are individualcomponents, integrated circuits, or boards, which when handled, tested, ortransported, could be destroyed by electrostatic fields or electrostatic di-scharge. These components are designated as ESDS (ElectroStatic DischargeSensitive Devices).Handling ESDS boards:

    The human body, working area and packing should be well grounded whenhandling ESDS components!

    Electronic boards should only be touched when absolutely necessary.

    Components may only be touched, if you are continuously grounded through an ESDS wristlet, you are wearing ESDS shoes or ESDS shoe grounding strips in con-

    junction with an ESDS floor surface. Boards may only be placed on conductive surfaces

    (desk with ESDS surface, conductive ESDS foam rubber, ESDS packingbag, ESDS transport containers).

    Boards may not be brought close to data terminals, monitors or televisionsets (a minimum of 10 cm should be kept between the board and thescreen).

    Boards may not be brought into contact with materials which can be char-gedup and which are highly insulating, e. g. plastic foils, insulating desk-tops, articles of clothing manufactured from manmade fibers.

    Measuring work may only be carried out on the boards if the measuring equipment is grounded (e. g. via the protective conduc-

    tor) or for floating measuring equipment, the probe is briefly discharged before

    making measurements (e. g. a bare control housing is touched). Only hold the control modules at the front panel

    Note

    Startup software is available for startingup/commissioning the main spindleand induction motor modules.

    Startup software Order No.: 6SN11532AX10ABDocumentation Order No.: 6SN11970AA300P

    ESD information

  • 07.94

    vi Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    SINUMERIK and SIMODRIVE Enhanced productivity as a result of fast, reliable commissioning

    Sophisticated industrial electronics, as are involved here, have to be handledespecially carefully. We regularly evaluate and investigate equipment which isreturned and in so doing we have identified some of the main fault causes,which in some cases results from incorrect handling during commissioning andtroubleshooting.

    The following check list should help you to simply commission the componentswe have supplied and guarantee a high availability when used in conjunctionwith your product or equipment.

    Observe all of the ESD measures when handling components.

    Tightenup all bolts and screws to the specified torque. Pay special atten-tion to the DC link bolt connections (1.8 Nm tightening torque).

    Correctly insert all connectors and lock/screw into place.

    Screw the control components into the power module.

    Observe the poweron sequence in the Planning Guide.If the unit is frequently powereddown and up, the DC link charge circuit islockedout. The DC link can only be charged again after it has cooled downfor several minutes with the supply off.

    Are there line supply/motor contactors connected to the drive converter?These are only switched in a nocurrent condition.

    Ground all components and connect all of the shields. Connection X131 isgrounded.

    Observe the load capability of the central power supply.

    Only discharge the unit at the DC link buses through a minimum of 10 .

    In operation, units with hard disks may only be stressed with a of max. 1 g(read/write error; defective).

    Use the correct software for the particular unit.

    Are OEM components (ISA/PCMCIA card) used? Their current drain mustlie within the specified values.

    CRT monitors may not be subject to magnetic fields (e.g. power supply unitcoils).

    When commissioning and fault finding, always proceed in a modular stepbystep fashion.This means: First commission the central controller and linesupply module, then connectup and commission the components one afteranother.

    Handling

    Check list

    03.96

  • 07.94

    vii Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    The units are designed for the specified mechanical, climatic and electricalambient conditions. None of the limit values may be exceeded, neither inoperation nor during transport. Please pay specific attention to the following: line supply conditions

    pollutants damaging gases climatic ambient conditions

    storage/transport shock stressing vibration stressing ambient temperature

    Further detailed information is provided in the Planning Guides and InstallationStartup Guides associated with our products.

    Further information

    03.96

  • 07.94

    viii Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    03.96

  • AL

    ALi Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    General information (AL)

    1 Permissible combinations of inverter modules and control cards AL/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • AL

    07.94

    ALii Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

  • AL

    Feed/main spindle controls with analog setpoint interface

    07.94

    AL/1-3 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Permissible combinations of invertermodules and control cards

    Table 1-1 Selection table to set the current controller referred to the resulting inverter currents

    SIMODRIVE 611 components

    Feed

    driv

    e co

    ntro

    l, an

    alog

    1ax

    is, u

    ser

    frien

    dly

    inte

    rfac e

    6SN1

    118

    0AA1

    10A

    A0

    Feed

    driv

    e co

    ntro

    l, an

    alog

    1ax

    is, s

    tand

    ard

    inte

    rface

    6SN1

    118

    0AD1

    10A

    A0

    Feed

    driv

    e co

    ntro

    l, an

    alog

    2ax

    is, s

    tand

    ard

    inte

    rface

    6SN1

    118

    0AE1

    10A

    A0

    Feed

    driv

    e re

    solve

    r con

    tr.,anal.

    6SN1

    118

    0BJ1

    10A

    A0

    1ax

    is, s

    tand

    ard

    inte

    rface

    Feed

    driv

    e re

    solve

    r con

    tr.,anal.

    6SN1

    118

    0BK1

    10A

    A0

    2ax

    is, s

    tand

    ard

    inte

    rface

    Mai

    n sp

    indl

    e dr

    ive c

    ontro

    l, an

    ano d

    irect

    mea

    s. s

    yste

    m6S

    N112

    10B

    A11

    0AA0

    Mai

    n sp

    indl

    e dr

    ive c

    ontro

    l, an

    adi

    r. m

    eas.

    sys

    tem

    , TTL

    si

    gnal

    s6S

    N112

    10B

    A12

    0AA0

    y

    Mai

    n sp

    indl

    e dr

    ive c

    ontr.

    , anal.

    ext

    erna

    l pos

    ition

    outp

    ut6S

    N112

    10B

    A13

    0AA0

    Indu

    ctio

    n m

    otor

    con

    trol,

    anal

    .Fi

    xed

    setp

    oint

    s, m

    ot. p

    ot.

    6SN1

    122

    0BA1

    10A

    A0

    Indu

    ctio

    n m

    otor

    con

    trol,

    anal

    anal.

    spee

    d, fi

    xed

    setp

    ., m

    ot.p

    o

    6SN1

    122

    0BA1

    20A

    A

    Mai

    n sp

    indl

    e dr

    ive c

    ontro

    l, an

    al

    6SN1

    121

    0BA1

    10A

    A1

    Indu

    ctio

    n m

    otor

    con

    trol,

    anal

    og

    6SN1

    122

    0BA1

    10A

    A1

    Parameter board, feeddrive, analog userfriendly6SN11140AA010AA0

    necessary _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____

    Main spindle option, feeddrive, analog, userfriendly

    6SN11140AA020AA

    possible _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____

    8A inverter module

    6SN1121AA00HA

    FD:4/8A

    FD:4/8A

    _____ FDR:3/6A

    _____ _____ _____ _____ IM:3/3/3 A

    IM:3/3/3 A

    _____ IM:3/3/3 A

    15A inverter module

    6SN1121AA00AAFD:7.5/15A

    FD:7.5/15A

    _____ FDR:5/10A

    _____ _____ _____ _____ IM:5/5/8 A

    IM:5/5/8 A

    _____ IM:5/5/8 A

    25A inverter module

    6SN1121AA00BA

    FD:12.5/25A

    FD:12.5/25A

    _____ FDR:9/18A

    _____ _____ _____ _____ IM:8/10/16A

    IM:8/10/16A

    _____ IM:8/10/16A

    50A inverter module

    6SN1121AA00CA

    FD:25/50A

    FD:25/50A

    _____ FDR:18/36A

    _____ MSD:24/32/32A

    MSD:24/32/32A

    MSD:24/32/32A

    IM:24/32/32A

    IM:24/32/32A

    MSD:24/32/32A

    IM:24/32/32A

    80A inverter module

    6SN1121AA00DAFD:40/80A

    FD:40/80A

    _____ FDR:28/56A

    _____ MSD:30/40/51A

    MSD:30/40/51A

    MSD:30/40/51A

    IM:30/40/51A

    IM:30/40/51A

    MSD:30/40/51A

    IM:30/40/51A

    120A inverter module

    6SN1121AA00GA

    _____ _____ _____ _____ _____ MSD:45/60/76A

    MSD:45/60/76A

    MSD:45/60/76A

    IM:45/60/76A

    IM:45/60/76A

    MSD:45/60/76A

    IM:45/60/76A

    108A inverter module

    6SN1121AA00LA_____ _____ _____ _____ _____ MSD:

    45/60/76AMSD:45/60/76A

    MSD:45/60/76A

    IM:45/60/76A

    IM:45/60/76A

    MSD:45/60/76A

    IM:45/60/76A

    160A inverter module

    6SN1121AA00EAFD:80/160A

    FD:80/160A

    _____ _____ _____ MSD:60/80/102A

    MSD:60/80/102A

    MSD:60/80/102A

    IM:60/80/102A

    IM:60/80/102A

    MSD:60/80/102A

    IM:60/80/102A

    200A inverter module

    6SN1121AA00FA

    FD:100/200A

    FD:100/200A

    _____ _____ _____ MSD:85/111/127A

    MSD:85/111/127A

    MSD:85/111/127A

    IM:85/111/127A

    IM:85/111/127A

    MSD:85/111/127A

    IM:85/111/127A

    04.97General (AL)

    1 Permissible combinations of inverter modules and control modules

    1

  • AL

    Vorschub/Hauptspindelregelungen mit analoger Sollwertschnittstelle

    07.94

    AL/1-4 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-1 Selection table to set the current controller referred to the resulting inverter currents

    SIMODRIVE 611 components

    Indu

    ctio

    n m

    otor

    con

    trol,

    anal

    og

    Mai

    n sp

    indl

    e dr

    ive c

    ontro

    l, an

    al

    6SN1

    122

    0BA1

    10A

    A1

    Indu

    ctio

    n m

    otor

    con

    trol,

    anal

    6SN1

    121

    0BA1

    10A

    A1

    anal.

    spee

    d, fi

    xed

    setp

    ., m

    ot.p

    ot.

    Indu

    ctio

    n m

    otor

    con

    trol,

    anal

    .

    6SN1

    122

    0BA1

    20A

    A

    Fixe

    d se

    tpoi

    nts,

    mot

    . pot

    .

    Mai

    n sp

    indl

    e dr

    ive c

    ontr.

    , anal.

    6SN1

    122

    0BA1

    10A

    A0

    ext

    erna

    l pos

    ition

    outp

    ut

    Mai

    n sp

    indl

    e dr

    ive c

    ontro

    l, an

    al

    6SN1

    121

    0BA1

    30A

    A0

    dir.

    meas.

    sys

    tem

    , TTL

    si

    gnal

    s

    Mai

    n sp

    indl

    e dr

    ive c

    ontro

    l, an

    al

    6SN1

    121

    0BA1

    20A

    A0y

    no d

    irect

    mea

    s. s

    yste

    m

    Feed

    driv

    e re

    solve

    r con

    tr.,anal.

    6SN1

    121

    0BA1

    10A

    A0

    Feed

    driv

    e re

    solve

    r con

    tr.,anal.

    6SN1

    118

    0BK1

    10A

    A0

    Feed

    driv

    e co

    ntro

    l, an

    alog

    2ax

    is, s

    tand

    ard

    inte

    rface

    6SN1

    118

    0BJ1

    10A

    A0

    Feed

    driv

    e co

    ntro

    l, an

    alog

    1ax

    is, s

    tand

    ard

    inte

    rface

    2ax

    is, s

    tand

    ard

    inte

    rface

    Feed

    driv

    e co

    ntro

    l, an

    alog

    6SN1

    118

    0AE1

    10A

    A0

    1ax

    is, s

    tand

    ard

    inte

    rface

    1ax

    is, u

    ser

    frien

    dly

    inte

    rface

    6SN1

    118

    0AD1

    10A

    A0

    6SN1

    118

    0AA1

    10A

    A0

    200A inverter modulepipe connection

    6SN1121AA00FA

    FD:100/200A

    FD:100/200A

    _____ _____ _____ MSD:85/110/127A

    MSD:85/110/127A

    MSD:85/110/127A

    IM:85/110/127A

    IM:85/110/127A

    IM:85/110/127A

    IM:85/110/127A

    300A inverter module

    6SN1121AA00JA_____ _____ _____ _____ _____ MSD:

    120/150/193A

    MSD:120/150/193A

    MSD:120/150/193A

    IM:120/150/193A

    IM:120/150/193A

    IM:120/150/193A

    IM:120/150/193A

    400A inverter module

    6SN1121AA00KA0

    _____ _____ _____ _____ _____ MSD:200/250/257A

    MSD:200/250/257A

    MSD:200/250/257A

    IM:200/250/257A

    IM:200/250/257A

    IM:200/250/257A

    IM:200/250/257A

    2x8A inverter module

    6SN1121AB00HA0

    _____ _____ FD:2x4/8A

    _____ FDR:2x3/6A

    _____ _____ _____ _____ _____ _____ _____

    2x15A inverter module

    6SN1121AB00AA0_____ _____ FD:

    2x7.5/15A_____ FDR:

    2x5/10A_____ _____ _____ _____ _____ _____ _____

    2x25A inverter module

    6SN1121AB00BA

    _____ _____ FD:2x12.5/25A

    _____ FDR:2x9/18A

    _____ _____ _____ _____ _____ _____ _____

    2x50A inverter module

    6SN1121AB00CA_____ _____ FD:

    2x25/50A_____ FDR:

    2x18/36A_____ _____ _____ _____ _____ _____ _____

    This StartUp Guide is valid for the following drive modules:

    6SN11301AA110A0 1axis feed drive module, userfriendly interface6SN11301AA120A0 1axis feed drive module, userfriendly interface

    with main spindle drive option

    6SN11301AD110A0 1axis feed drive module, standard interface6SN11301AE110A0 2axis feed drive module, standard interface6SN11351BA10A0 MSD module6SN11401BA10A0 IM module

    04.97General (AL)1 Permissible combinations of inverter modules and control modules

  • AL

    07.94

    AL/1-5 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Note

    The document describes all of the steps necessary to commission an installedSIMODRIVE drive group. Please refer to the associated Planning Guides foradditional technical information, e.g. regarding

    ambient conditions

    recommended circuits

    connecting diagrams

    dimension sheets/dimension drawings

    Please refer to the associate Planning Guide:SIMODRIVE 611Transistor PWM Inverters for AC Feed Drives and AC Main Spindle DrivesOrder No.: 6SN11970AA000PSIMODRIVEAC Motors for Feed and Main Spindle DrivesOrder No.: 6SN11970AA200P

    04.97General (AL)

    1 Permissible combinations of inverter modules and control modules

  • AL

    07.94

    AL/1-6 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    04.97General (AL)1 Permissible combinations of inverter modules and control modules

  • NE

    NEi Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Supply infeed (NE)

    1 Standard settings, NE modules (UE and I/R modules), monitoring andpulsed resistor modules NE/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2 Maintenance and diagnostics NE/2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Terminals and relay functions NE/2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3 Appendix NE/3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Connecting terminals NE, monitoring and pulsed resistor modules NE/3-12. . 3.2 Connecting terminals, UE module 5/10 kW NE/3-14. . . . . . . . . . . . . . . . . . . . . .

  • NE

    07.94

    NEii Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

  • NE

    07.94

    NE/1-3 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Standard settings, NE modules (UE andI/R modules), monitoring and pulsed resi-stor modules

    ! WichtigObserve the information for sinusoidal current control for I/R modules!

    A switch S1 is provided on the upper side of the NE and monitoring module to set the fol-lowing functions:

    Sinusoidal current control

    ON: OFF:

    Vsupply=415V10% VDClink=625 V1)

    Fault messageRegen. feedback off1)

    Vsupply=415V10% VDC link=600 V1)

    Regenerative feedback on

    1

    2

    34VSupply=480V+6%10%

    Ready signal

    S1

    Controlled infeed off Control infeed56

    Standard, refer to S1.1

    Squarewave current control

    Standard setting

    Fig. 1-1 DIL switch S1

    ! WichtigFor I/R modules Order No. 6SN1141001 the basic setting is forsinusoidal control (closedloop). Observe the information/instructions, PageNE13!

    ! WichtigBefore the equipment is poweredup or down using the main switch or a line contactor,terminal 63 (pulse enable) and/or terminal 48 (start terminal, contactor control) should bedeenergized or disconnected!

    1) Only possible for I/R modules, monitoring thresholds are increased for all NE modules

    Supply infeed (NE)1 Standard settings, NE modules, monitoring and pulsed resistor modules04.97

    1

  • NE

    07.94

    NE/1-4 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    OFF: I/R module Vsupply =400V10%; VDC link=600VUE module Vsupply =400V10%; VDC link=1.35*Vsupplymonitoring thresholds: (I/R, UE, monitoring modules)pulsed resistor on =644V; pulsed resistor off =618VVDC link>> =710V;

    ON: I/R module Vsupply =415V10%; VDC link=625VUE module Vsupply =415V10%; VDC link=1.35*VsupplyMonitoring thresholds: (I/R, UE, monitoring modules)pulsed resistor on =670V; pulsed resistor off =640VVDC link>> =740V;

    OFF: Ready signal (X111 ready relay)For S1.2=OFF, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminals NS1NS2 connected,

    terminal 48 enabled)

    terminal 63,64=ENERGIZED no fault present (also not on feed drive 611A Standard, or 611D drives) feed drive with standard interface or resolver for setting Ready is enabled (terminals 663,65)

    ON: Fault message (X111 ready relay)For S1.2=ON, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminals NS1NS2 connected,

    terminal 48 enabled)

    no fault present (also not on feed drive 611A Standard, or 611D drives) feed drive with standard interface or resolver for setting ready is enabled (terminals 663,65);

    OFF: Standard setting, regenerative feedback activeI/R modules are capable of regenerative feedback UE modules: The pulsed resistor in the module is effective

    ON: Regenerative feedback switchedout (disabled)I/R module: Regenerative feedback operation is inhibitedUE modules: The pulsed resistor in the module is not effective

    Comment: This function is only effective for UE 10 kW fromMLFB (Order No.): 6SN11461AC000AA1 (however, not for UE

    28kW)

    OFF: Standard setting for all NE modules, refer to S1.1 ON: Vsupply =480V+6%10%; VDC link=1.35*Vsupply in the infeed direction

    Monitoring thresholds: (I/R, UE, monitoring modules)pulsed resistor on =744V; pulsed resistor off =718VVDC link>> =795V.

    Comment: Uncontrolled operation in the infeed direction. (only valid for Order No. 6SN1141001

    Switch S 1.1 :

    Switch S 1.2 :

    Switch S 1.3 :

    Switch S 1.4 :

    Supply infeed (NE)1 Standard settings, NE modules, monitoring and pulsed resistor modules 04.97

  • NE

    07.94

    NE/1-5 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Note

    Only in conjunction with power modules, Order No. (6SN1141001).For motors with shaft height

  • NE

    07.94

    NE/1-6 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Supply infeed (NE)1 Standard settings, NE modules, monitoring and pulsed resistor modules 04.97

  • NE

    07.94

    NE/2-7 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Service and diagnostics

    Display elements of the monitoring and NE modules

    1 2

    3 45 6

    1 LED, red 15 V electronics power supply faulted2 LED, red 5 V voltage level faulted3 LED green external enable signals not available

    (terminal 63 and/or terminal 64 missing)4 LED yellow DC link charged5 LED, red line supply fault (single or multiphase supply failure at the

    terminals U1, V1, W1) 1) commutating reactor either not available or incorrectly selected, fault level of the line supply or transformer too low

    6 LED red DC link overvoltage possible causes: Regenerative feedback off, settingup operation, line supply fault, for UE pulsedresistor not operational, line supply voltage too high, dynamic overload condition

    Effects:1 red LED bright: Pulses for the complete drive group are canceled2 red LED bright: Pulses for the complete drive group are canceled4 yellow LED dark: xxxx5 red LED bright: 1) Only the I/R module pulses are canceled (regenerative feedback

    no longer possible. Axes first continue to run. Ready relay dropsout6 red LED bright: Pulses for the complete drive group are canceled

    1) Line supply fault identification time approx. 30msLine supply fault is identified for a threephase voltage < 280V.For 1phase supply failure, the drive axes pulses are canceled after approx. 1 min.(latched signal) valid for Order No. 6SN11141001

    Supply infeed (NE)04.97 2 Service and diagnostics

    2

  • NE

    07.94

    NE/2-8 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    2.1 Terminals and relay functions X111: READY RELAY:

    terminals 72 73.1: NO contact in the quiescent state terminals 73.2 74: NC contact in the quiescent state

    For S1.2=OFF, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminals NS1NS2 connected, terminal 48 enabled) terminals 63, 64 =ENERGIZED no fault present (also not on feed drive 611A Standard, or 611D drives) feed drive with Standard interface or resolver is enabled for the ready setting (terminals663, 65)For S1.2=ON, the relay switches if the following conditions are fulfilled: internal main contactor CLOSED (terminal NS1NS2 connected, terminal 48 enabled) no fault present (also not on feed drive 611A Standard, and 611D drives) feed drive with Standard interface or resolver enabled for this ready setting (terminals 663, 65).

    X121: I2t_alarm and motor overtemperature:terminal 5.1 5.2: NO contact in the quiescent stateterminal 5.1 5.3: NC contact in the quiescent stateThis relay switches, if: the > heatsink temperature monitoring responds at the I/R the > motor temperature monitoring responds at the 611D feed drive

    > heatsink temperature monitoring responds at the feed drive 611A userfriendly

    > motor temperature monitoring responds> heatsink temperature monitoring responds> I2ttemperature monitoring responds (nonlatching)

    at 611A Standard > Motor temperature monitoring responds> heatsink temperature monitoring responds

    X171: Terminal NS1NS2 (coil circuit of the internal line supply and precharging contac-tor): is used to electrically isolate from the line supply (signal contact, terminals 111213 must be interrogated) may only be switched if terminal 48 is opencircuit (without any restriction from Order No. 6SN1141010 for 10, 16 and 55kW, from Order No. 6SN1141020 for 36kW, all 80 and 120kW)

    terminal 48: Start has the highest priority Sequence: Precharging ON interrogation VDC link310V and VDC link2*Vsupply50V

    > 500ms precharging contactor OUT, interrogation whetherOUT, main contactor IN>1s internal enable signals (for I/R and module group)

    saved during precharging

    terminal 63: Pulse enable has the highest priority for pulse enable of all the modules acts instantaneously (without delay)

    Terminal 64: Drive enable acts instantaneously on all modules when the signal is withdrawn, nset is set to 0 for all drives, and

    > for main spindle drive / induction motor module 611 A, the pulses are canceled after a speed, which can be set, is fallen below. The drive is braked along the ramp.

    Supply infeed (NE)04.972.1 Terminal and relay functions

  • NE

    07.94

    NE/2-9 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    > for feed drives 611 A, after the selected timer stages have expired (as supplied: 240ms) all of the controllers and pulses are inhibited. The drive

    brakes along the current limit. > for 611D drives, the pulses are deleted after a selectable speed has been fallen below and/or a time which can be set, has expired. The drive brakes along the set limits. (For spindles, a ramp can be achieved via regenerative limiting [kW])

    terminal 112: Settingup operation (Vmin 3ph. 24V AC or 34 V DC) the VDC link closedloop control is inhibited regenerative feedback is not possible, i.e. when braking, VDC link can be >600V! this function is interrogated with the start inhibit signal, terminal AS1AS2.

    ! CautionFor induction motors, even for low VDC link, high speeds can be reached! terminals AS1AS2: start inhibit signal

    terminals AS1AS2 closed means start inhibit is effective (settingup operation) terminals 111, 113, 213: signal contact, internal line contactor

    terminals 111 113: NO contact terminals 111 213: NC contact (for I/R 16kW and UE 10kW only from

    Order No. 6SN1141010 ) terminal 19: FR:

    reference ground, enable voltage floating (connected to the general reference ground, terminal 15 via 10k) it is not permissible to connect terminal 19 with terminal 15 (connect to PE rail or X131)

    terminal 9: FR+: 24V enable voltage max. load capability of the power supply:500mA (corresponds to 8 slots;1 optocoupler input

    requires 12mA)

    X 141: electronic voltages: terminal 7: P24 +20.4 to 28.8V / 50mA terminal 45: P15 +15V / 10mA terminal 44: N15 15V / 10mA terminal 10: N24 20.4 to 28.8V / 50mA terminal 15: M 0V it is not permissible to connect terminal 15 to PE (ground loop) it is not permissible to connect terminal 15 with terminal 19

    (shortcircuit via reactor, which internally connects terminal 15 with X131)

    terminal L1L2 for 80kW and 120kW I/R is used to supply the coil of the internal line contactor is supplied directly at the line supply with 2ph. 400V AC (not between I/R and reactor) fuse: IN 4 A, type gL

    Fan connection for 80 and 120kW I/R 3ph. 360 to 510V AC , 4565 Hz directly at the line supply (not between the I/R and reactor) observe the rotating field (phase sequence)! fuse: IN 1.5 A (motor protection circuitbreaker)

    Supply infeed (NE)04.97 2.1 Terminal and relay functions

  • NE

    07.94

    NE/2-10 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    6 conductor connection with additional connection of the power supply at the DClink: for this operating mode, terminals 2U1, 2V1 and 2W1 of the power supply must be supplied with the line supply voltage between the series reactor and I/R, otherwise the power supply will be destroyed! This is also valid for the monitoring modules!

    Monitoring module with line supply connection and additional connection of the power sup-ply to the DC link: for this operating mode, terminals 2U1, 2V1 and 2W1 of the power supply must be supplied with the line supply voltage between the series reactor and I/R, as otherwise the power supply will be destroyed. terminal 63 must be switched via the ready relay of the I/R in order to prevent the module, to the right of the monitoring module, starting during precharging.

    If a line supply fault is displayed or if the yellow LED is dark, the overvoltage limiting modulemust be checked. Procedure:

    1. Powerdown the drive converter (into a novoltage condition)2. Remove the overvoltage limiting module and insert connector X181 on the NE module.

    If the NE module functions, then the overvoltage limiting module is defect and must bereplaced. Otherwise, check the line supply and if required, also the NE module/drive group.

    Note

    In this way, operation can be continued, but without overvoltage protection.

    3. Insert the overvoltage limiting module 566018.9415.00 up to its end stop, and insertconnector X181 on the overvoltage limiting module.

    Diagnostic instruc-tions

    Supply infeed (NE)04.972.1 Terminal and relay functions

  • NE

    07.94

    NE/3-11 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Appendix

    Note

    When using nonPELV circuits at terminals AS1, AS2, terminal 111, terminal 113, terminal213, connector coding must be used to prevent the connector being interchanged (referto EN 602041 Section 6.4) refer to Catalog NC 60.1 for the Order No. of the coding con-nector. Only PELV circuits may be connected at terminal 19.

    Supply infeed (NE)3.1 Connecting terminals NE, monitoring and pulsed resistor modules

    3

  • NE

    07.94

    NE/3-12 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    3.1 Connecting terminals NE, monitoring and pulsedresistor modules

    Table 3-1 Terminal functions

    Term.No.

    Desi-gna-tion

    FunctionTyp

    e1)

    Typ. voltage/limit values Max. crosssec-tionTerminals availa-

    ble in 3)

    U1V1

    W1

    Supply I 3ph. 400 V AC Refer to the Plan-ning Guide I/R, UE

    L1L2

    Supply connection for contactor

    II

    2ph. 400 V AC dir. at supplyL1, L2, L3, refer to Sec. 9.2

    16mm2/10mm2 4)16mm2/10mm2 4)

    I/R 80/104 kW,120/156 kW

    PEP600M600

    Protective conductorDC link DC link

    II/OI/O

    0 V+300 V300 V

    BoltBusbarBusbar

    I/R, UE, MM, PR

    Grounding bar5) I/O 300 V Busbar I/R, UE

    P600M600

    DC linkDC link

    II

    +300 V300 V

    16mm2/10mm2 4)16mm2/10mm2 4) MM

    1R,2R,3R

    Internal resistor con-nection

    I/O 300 V 16mm2/10mm2 4)PR

    X131 Electronics M I/O 0 V 16mm2/10mm2 4) I/R, UE, MMX351 Equipment bus I/O Various Ribbon cable I/R, UE, MM, PR

    M500

    P500

    1U12U11V12V11W12W1

    X181

    X181

    X181X181X181X181X181X181

    DC link power supplyDC link power supplyOutput L1Input L1Output L2Input L2Output L3Input L3

    I

    I

    OIOIOI

    600 V DC

    600 V DC

    3ph. 400 V AC 3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC

    1.5 mm2

    1.5 mm2

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    I/R, UE, MM

    745441015R

    X141X141X141X141X141X141

    P24P15N15N24MRESET6)

    OOOOOI

    +20.4...28.8 V/50 mA+15 V/10 mA15 V/10 mA20.4...28.8 V/50 mA0 VTerm.15/RE = 10 k

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    I/R, UE, MM

    5.35.25.16399

    6419

    X121X121X121X121X121X121X121

    Relay contactsGroup messageI2t/motor temp.

    Pulse enable2)Enable voltage2)8)Enable voltage2)8)Drive enable2)Enable voltage, refe-rence potential

    NCNO

    IIAAI

    50 V DC/0.5 A/12 VA max5 V DC/3 mA min

    +13 V...30 V/RE = 1.5 k+24 V+24 V+13 V...30 V/RE = 1.5 k0 V

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    I/R, UE, MM

    Supply infeed (NE)3.1 Connecting terminals NE, monitoring and pulsed resistor modules 04.97

  • NE

    07.94

    NE/3-13 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 3-1 Terminal functions

    Term.No.

    Terminals availa-ble in 3)

    Max. crosssec-tionTyp. voltage/limit values

    Type1)

    FunctionDesi-gna-tion

    74nc

    73.273.1

    nc72

    X111X111X111X111X111X111

    Relay contactReady signal

    NC

    II

    NO

    1ph. 250V AC/50V DC/2A max5V DC/3mA min

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    I/R, UE, MM

    9112

    X161X161

    Enable voltage2)8)Settingup operation/Standard operation2)

    OI

    +24 V+21 V...30 V/RE = 1.5 k

    1.5 mm21.5 mm2 I/R, UE, MM

    48111213

    113

    X161X161X161

    X161

    Contactor control 2)

    Signaling contacts

    Line contactor

    II

    NC7)

    NO

    +13 V...30 V/RE = 1.5 k+30 V/1 A (111113)1ph. 250 V AC/50 V DC/2 A max17 V DC/3 mA min

    1.5 mm21.5 mm21.5 mm2

    1.5 mm2I/R, UE

    AS1AS2

    X172X172

    Signaling contactStart inhibit (termi-nal112)

    INC

    250V AC/1A/50V DC/2A max5 V DC/10 mA min

    1.5 mm21.5 mm2 I/R

    NS1NS2

    X171X171

    Coil contact for line,precharging contac-tor

    OI

    +24 V 1.5 mm21.5 mm2 I/R, UE

    19

    50

    X221

    X221

    Enable voltageReference potentialControl contact for fastdischarge

    O

    I

    0 V

    0 V

    1.5 mm2

    1.5 mm2 PR

    1) I = Input, O = Output, NC = NC contact, NO = NO contact (for signal: Closed= high/open= low)2) Terminal 19 is the reference ground (is connected inside the module with 10 k to the general reference groundX131/terminal 15). It is not

    permissible to connect terminal 15 to PE or to terminal 19. Donot connect external voltage sources to terminal 15! Termi-nal 19 can be

    connected with X131.3) I/R = infeed/regenerative feedback module;

    UE = uncontrolled infeed; monitoring module; PW = pulsedresistor module

    4) The 1st number is valid for cable lugs. The second number is valid for finelystranded conductors without connector sleeves.

    5) The grounding bar is used to ground the DC link M bus via 100 k (it should preferably always be inserted for nongrounded supply networks).

    6) RESET = resets the fault memory, edge triggered for the complete drive group (terminal R terminal 15 = RESET)7) terminal 111213 positivelydriven NC contact (for I/R 16 kW and UE 10kW, only from MLFB (Order No.6SN1141010).

    Terminal 111113, NO contact, not positively driven8) max. current load of terminals 919: 0.5A

    Supply infeed (NE)3.1 Connecting terminals NE, monitoring and pulsed resistor modules04.97

  • NE

    07.94

    NE/3-14 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    3.2 Connecting terminals, UE module 5/10 kW

    Table 3-2 Terminal functions

    Term.No.

    Desi-gnation Function

    Type1) Typ. voltage/limit values Max. crosssection

    U1V1

    W1

    X1 Supply I 3ph. 400 V AC 4 mm2 finely strandedwithout connector sleeves

    6 mm2 with cable lug

    PE1PE2

    X131X351

    Protective conductor

    Electronics MEquipment busGrounding bar3)

    I

    II/OI/O

    0 V

    0 VVarious300 V

    M5 thread

    M4 thread34pin ribbon cable

    Busbar

    P600M600

    DC linkDC link

    I/OI/O

    +300 V300 V

    BusbarBusbar

    M500P5001U12U11V12V11W12W1

    X181X181X181X181X181X181X181X181

    DC link power supplyDC link power supplyOutput L1Input L1Output L2Input L2Output L3Input L3

    IIOIOIOI

    300 V+300 V3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC3ph. 400 V AC

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    5.35.25.1nc

    X121AX121AX121AX121A

    Relay contactGroup signalI2t/motor temperature

    NCNO

    I

    50 V DC/0.5 A/12 VA max5 V DC/3 mA min

    1.5 mm21.5 mm21.5 mm21.5 mm2

    7473.273.1

    72

    X121BX121BX121BX121B

    Relay signalReady/fault

    NCII

    NO

    1ph. 250 V AC/50 V DC/2 Amax

    5 V DC/3 mA min

    1.5 mm21.5 mm21.5 mm21.5 mm2

    6399

    64R

    19

    X141AX141AX141AX141AX141AX141A

    Pulse enable2)FR+2)4)FR+2)4)Drive enable2)RESET2)FR, reference ground, enablevoltage

    IOOIIO

    +13 V...30 V/RE = 1.5 k+24 V+24 V+13 V...30 V/RE = 1.5 k0/+24 V0 V

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    111213

    X161X161

    Signaling contactLine contactor

    INC

    1ph. 250 V AC/50 V DC/2 A17 V DC/3 mA min

    1.5 mm21.5 mm2

    911248

    NS1NS2

    15

    X141BX141BX141BX141BX141BX141B

    FR+2)4)Settingup/standard operation2)Contactor control2)

    M

    Coil contact for the line supply precharging contactor

    OIIOIO

    +24 V+13 V...30 V/RE = 1.5 k+13 V...30 V/RE = 1.5 k+24 V0/+24 V0 V

    1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2

    1) I = Input, O = Output, NC = NC contact, NO = NO contact (for signal: Closed= high/open= low)2) Terminal 19 is the reference terminal (connected in the module to general reference ground X131

    with 10 k).3) The grounding bar is used to ground the DC link M bar via 100 k (this should always be

    inserted for nongrounded supply networks).4) max. current loading of terminals 9 19: A1

    Supply infeed (NE)04.973.2 Connecting terminals, UE module 5/10 kW

  • VS

    VSi Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Feed modules (VS)

    1 Short startup, standard settings VS/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Tachometer adaptation for motors with tachometer voltages 3

    16.5 V at rated speed VS/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Current controller settings VS/1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2 Speed controller optimization VS/2-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Tachometer adjustment VS/2-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Setting the proportional gain Kp without adaptation VS/2-18. . . . . . . . . . . . . . . 2.3 Setting the integral action time TN without adaptation VS/2-19. . . . . . . . . . . . . 2.4 Integral action time with adaptation (if required) VS/2-20. . . . . . . . . . . . . . . . . . 2.5 Proportional gain with adaptation (only userfriendly interface) VS/2-21. . . . . 2.6 Setting the adaptation range (generally not required) VS/2-22. . . . . . . . . . . . . . 2.7 I component limiting of the speed controller VS/2-22. . . . . . . . . . . . . . . . . . . . . . 2.8 Drift offset VS/2-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    3 Startup, supplementary functions VS/3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Setting elements with standard interface VS/3-25. . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 Dimensioning the setting elements (standard interface) VS/3-26. . . . . . . . . . . . 3.2 Setting elements with userfriendly interface VS/3-29. . . . . . . . . . . . . . . . . . . . .

    4 Setpoint interfaces VS/4-33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Startup with main spindle drive option VS/5-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.1 Presettings VS/5-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.1 Settings with the control board removed VS/5-35. . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2 Settings in operation VS/5-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Analog outputs VS/5-40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    6 Free for supplementary texts VS/6-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Poweron VS/7-43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Maintenance and diagnostics VS/8-45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    8.1 Test sockets and display elements of the feed modules VS/8-45. . . . . . . . . . . . 8.1.1 Userfriendly interface VS/8-45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1.2 Standard interface VS/8-47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 Troubleshooting VS/8-48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • VS

    07.94

    VSii Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    9 Appendix VS/9-49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 Connecting terminals VS/9-49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2 Block diagram, MSD option board VS/9-52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.3 Block diagram, parameter board VS/9-53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4 Block diagram, standard interface VS/9-54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Startup is subdivided into steps; after the standard setting, this can be follo-wed by an additional startup step or the drive converter poweredup.

    Short startupStandard settings

    Speed controller op-timization

    Supplementary functions

    Setpointinterfaces

    Startup with mainspind. drive option

    Power.up, Sect. 7

    Service anddiagnostics

    Appendix

    Sect. 1

    Sect. 2

    Sect. 3

    Sect. 4

    Sect. 5

    Sect. 8

    Sect. 9

    Startup steps of thefeed drive moduleswith userfriendlyand standard interface

    12.94

  • VS

    07.94

    VS/1-3 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Short startup, standard settings

    The setting elements for the userfriendly interface are located on the parame-ter board, for the standard interface, on the control (refer to Section 9 Appen-dix). The tachometer adaptation, current normalization and current controllergain parameters should be set for a standard startup.

    1.1 Tachometer adaptation for motors with tachometer vol-tages 16.5 V at rated speed

    Only for 1FT503AF71 and 1FT504AF71 motors

    All three contacts, switch S1 (S4 for the 2nd axis standard interface) = ONFurther, an adjustment can be made using discrete resistors, refer to Section 3.1 - 3.2.

    1.2 Current controller settingsThe settings for the current limit and current controller gain Kp(I) can be takenfrom the adaptation tables, Table 1-3 up to Table 1-9. If the required feed mo-dule/motor combination cannot be found, the values can be determined usingthe associated formulas.

    Parameter board, switch S2

    Control board, switch S2 (S5 for 2nd axis)

    Note

    The following setting values are valid for both control versions, as long as, inindividual cases, specific reference is not made to differences.

    Userfriendly andstandard interface

    Userfriendly inter-face

    Standard interface

    Feed modules (VS)1 Short startup, standard settings04.97

    1

  • VS

    07.94

    VS/1-4 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Current limit Imax (adjusted maximum current)Ilimit (peak current of the power module)

    [%]=

    Table 1-1 Current limit

    S2.xor

    S5.xto ON

    2 3 23

    4 24

    34

    234

    5 25

    35

    235

    45

    345

    2345

    (%) 100 85 68 61 50 46 41 39 36 34 30 29 26 24 23

    The current limit must be reduced at least to the peak value permitted for themotor. It may be necessary to reduce it still further depending on the mechanicalsystem which is driven.

    Imax =maximum axis current set in ALA =motor winding inductance in mH (refer to the configuringguide, AC

    motors for feed and main spindledrives)

    Imax LA40

    Kp(I) t

    Table 1-2 Current controller gain

    S2.xandS5.xto ON

    6 7 67

    8 68

    78

    9 69

    79

    679

    89

    789

    6789

    Kp(I) 0.5 1 2 2.5 4 4.5 5.5 6 6.5 7.5 8 9.5 11 11.5

    The setting range of the current controller gain can be additionally increasedusing R15 on the parameter board.The following formula is valid for S2.6 to S2.9 closed (ON):

    Kp(I) 11, 5 1230 R15

    Current actual va-lue normalization

    Current controllergain Kp(I)

    Userfriendly inter-face

    Feed modules (VS)04.971.2 Current controller settings

  • VS

    07.94

    VS/1-5 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Definition: o = Contact in the basic OFF settingx = Contact in the ON setting

    Table 1-3 Adaptation table for feed module 4/8 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5034AK71 0.5 0.93 6000 x o x o 3.68 o x o o 2.0

    5036AK71 0.75 1.4 6000 o x o o 5.44 o x o o 2.0

    5042AF715042AK71

    0.660.66

    0.751.2

    30006000

    xx

    ox

    oo

    xo

    2.724.88

    xx

    xx

    oo

    oo

    2.52.5

    5044AF715044AK71

    1.31.3

    1.52.3

    30006000

    oo

    xo

    oo

    oo

    5.448.0

    xx

    xo

    oo

    oo

    2.51.0

    5046AF71 2.6 3.0 3000 o o o o 8.0 o x o o 2.0

    5062AC715062AF715062AG715062AK71

    2.22.22.22.2

    1.32.02.73.9

    2000300040006000

    oooo

    xooo

    oooo

    oooo

    5.448.08.08.0

    xoox

    xxoo

    xoxo

    xxoo

    11.57.54.01.0

    5064AC71 4.5 2.7 2000 o o o o 8.0 o x o x 7.55066AC71 6.5 3.9 2000 o o o o 8.0 x o x o 4.55070AC715070AF715070AG71

    3.03.03.0

    1.82.63.6

    200030004000

    ooo

    ooo

    ooo

    ooo

    8.08.08.0

    xox

    xxo

    xox

    xxo

    11.57.54.5

    5071AC71 4.5 2.9 2000 o o o o 8.0 x x o x 8.0

    1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    Adaptation tables

    Feed modules (VS)04.97 1.2 Current controller settings03.96

  • VS

    07.94

    VS/1-6 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-4 Adaptation table for feed module 7.5/15 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5034AK71 0.5 0.93 6000 o x x x 3.68 o x o o 2.0

    5036AK71 0.75 1.4 6000 o o o x 5.44 o x o o 2.0

    5042AF715042AK71

    0.660.66

    0.751.2

    30006000

    xx

    xx

    xo

    xx

    3.454.5

    oo

    ox

    xo

    oo

    4.02.0

    5044AF715044AK71

    1.31.3

    1.52.3

    30006000

    xx

    xx

    xo

    oo

    5.859.15

    oo

    ox

    xo

    oo

    4.02.0

    5046AF715046AK71

    2.62.6

    3.04.7

    30006000

    xo

    oo

    oo

    oo

    12.715.0

    ox

    oo

    xo

    oo

    4.01.0

    5062AC715062AF715062AG715062AK71

    2.22.22.22.2

    1.32.02.73.9

    2000300040006000

    xooo

    ooxo

    oxoo

    xooo

    5.17.510.215.0

    oxox

    xoxx

    xoxo

    xxoo

    11.06.55.52.5

    5064AC715064AF715064AG71

    4.54.54.5

    2.74.15.5

    200030004000

    ooo

    xoo

    ooo

    ooo

    10.215.015.0

    oxx

    oox

    xoo

    xxo

    9.56.52.5

    5066AC715066AF71

    6.56.5

    3.96.0

    20003000

    oo

    oo

    oo

    oo

    15.015.0

    oo

    oo

    xx

    xo

    9.54.0

    5070AC715070AF715070AG715070AK71

    3.03.03.03.0

    1.82.63.65.3

    2000300040006000

    oooo

    oxoo

    xooo

    oooo

    7.510.215.015.0

    xoxo

    xoxo

    xxox

    xxxo

    11.59.58.04.0

    5071AC715071AF715071AG71

    4.54.54.5

    2.94.35.2

    200030004000

    xoo

    ooo

    ooo

    ooo

    12.715.015.0

    xxx

    xoo

    xox

    xxo

    11.56.54.5

    5072AC71 10.0 6.1 2000 o o o o 15.0 x x o x 8.05073AC715073AF71

    7.07.0

    4.36.4

    20003000

    oo

    oo

    oo

    oo

    15.015.0

    oo

    oo

    xx

    xo

    9.54.0

    5100AC71 10.0 6.2 2000 o o o o 15.0 o x x o 5.5

    1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    Feed modules (VS)04.971.2 Current controller settings 03.96

  • VS

    07.94

    VS/1-7 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-5 Adaptation table for feed module 12.5/25 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5036AK71 0.75 1.4 6000 x x x x 5.75 o x o o 2.0

    5044AF715044AK71

    1.31.3

    1.52.3

    30006000

    oo

    xo

    xo

    xx

    6.09.0

    oo

    ox

    xo

    oo

    4.02.0

    5046AF715046AK71

    2.62.6

    3.04.7

    30006000

    oo

    ox

    xo

    oo

    12.517.0

    oo

    ox

    xo

    oo

    4.02.0

    5062AC715062AF715062AG715062AK71

    2.22.22.22.2

    1.32.02.73.9

    2000300040006000

    xxxx

    xoox

    xoxo

    xxoo

    5.758.5

    10.2515.75

    xxox

    xxxx

    xoxo

    xxoo

    11.58.05.52.5

    5064AC715064AF715064AG715064AK71

    4.54.54.54.5

    2.74.15.58.0

    2000300040006000

    xooo

    oxoo

    xooo

    oooo

    10.2517.025.025.0

    xxox

    xoxx

    xoxo

    xxoo

    11.56.55.52.5

    5066AC715066AF715066AG715066AK71

    6.56.56.56.5

    3.96.07.911.6

    2000300040006000

    oooo

    xooo

    oooo

    oooo

    17.025.025.025.0

    oxxo

    ooxx

    xooo

    xxoo

    9.56.52.52.0

    5070AC715070AF715070AG715070AK71

    3.03.03.03.0

    1.82.63.65.3

    2000300040006000

    oxoo

    xoxo

    oxoo

    xooo

    7.511.517.025.0

    xoox

    xxoo

    xxxo

    xxxx

    11.511.09.56.5

    5071AC715071AF715071AG715071AK71

    4.54.54.54.5

    2.94.35.27.9

    2000300040006000

    oooo

    oxoo

    xooo

    oooo

    12.517.025.025.0

    xxxx

    xxxx

    xooo

    xxxo

    11.58.08.02.5

    5072AC715072AF715072AG71

    10.010.010.0

    6.19.112.0

    200030004000

    ooo

    ooo

    ooo

    ooo

    25.025.025.0

    xox

    xox

    xoo

    xxo

    11.56.02.5

    5073AC715073AF715073AG715073AK71

    7.07.07.07.0

    4.36.48.112.5

    2000300040006000

    oooo

    xooo

    oooo

    oooo

    17.025.025.025.0

    oxxx

    oooo

    xoxo

    xxoo

    9.56.54.51.0

    5074AC71 14.0 8.5 2000 o o o o 25.0 x x o x 8.05076AC71 18.0 11.5 2000 o o o o 25.0 o x x o 5.55100AC715100AF715100AG71

    10.010.010.0

    6.29.212.5

    200030004000

    ooo

    ooo

    ooo

    ooo

    25.025.025.0

    oox

    oox

    xxo

    xoo

    9.54.02.5

    5101AC71 15.0 9.4 2000 o o o o 25.0 o x x o 5.55102AA71 27.0 9.9 1200 o o o o 25.0 x x o x 8.0

    5103AC71 19.0 12.0 2000 o o o o 25.0 o o x o 4.0

    1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    Feed modules (VS)04.97 1.2 Current controller settings03.96

  • VS

    07.94

    VS/1-8 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-6 Adaptation table for feed module 25/50 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5044AK71 1.3 2.3 6000 o o x x 13.0 x x o o 2.5

    5046AF715046AK71

    2.62.6

    3.04.7

    30006000

    oo

    xo

    ox

    xo

    15.025.0

    ox

    ox

    xo

    oo

    4.02.5

    5062AG715062AK71

    2.22.2

    2.73.9

    40006000

    xo

    ox

    xx

    xo

    13.019.5

    xx

    oo

    ox

    xo

    6.54.5

    5064AC715064AF715064AG715064AK71

    4.54.54.54.5

    2.74.15.58.0

    2000300040006000

    oxoo

    oxox

    xxxo

    xooo

    13.019.525.034.0

    xxox

    xxxx

    xoxo

    xxoo

    11.58.05.52.5

    5066AC715066AF715066AG715066AK71

    6.56.56.56.5

    3.96.07.911.6

    2000300040006000

    xxoo

    xxxo

    xooo

    oooo

    19.530.534.050.0

    xxxo

    xxoo

    xoxx

    xxoo

    11.58.04.54.0

    5070AF715070AG715070AK71

    3.03.03.0

    2.63.65.3

    300040006000

    oxo

    xoo

    xox

    xxo

    12.017.025.0

    xox

    xoo

    xxo

    xxx

    11.59.56.5

    5071AC715071AF715071AG715071AK71

    4.54.54.54.5

    2.94.35.27.9

    2000300040006000

    oooo

    oxox

    xxxo

    xooo

    13.020.525.034.0

    xoxo

    xoxo

    xxox

    xxxo

    11.59.58.04.0

    5072AC715072AF715072AG715072AK71

    10.010.010.010.0

    6.19.112.017.5

    2000300040006000

    oxoo

    oooo

    xooo

    oooo

    25.042.550.050.0

    xoxx

    xoox

    xxoo

    xxxo

    11.59.56.52.5

    5073AC715073AF715073AG715073AK71

    7.07.07.07.0

    4.36.48.112.5

    2000300040006000

    oxxo

    xxoo

    xooo

    oooo

    20.530.542.550.0

    xxox

    xxxx

    xooo

    xxxo

    11.58.07.52.5

    5074AC715074AF715074AG715074AK71

    14.014.014.014.0

    8.513.016.525.0

    2000300040006000

    xooo

    oooo

    oooo

    oooo

    42.550.050.050.0

    xxxx

    xooo

    xoxo

    xxoo

    11.56.54.51.0

    5076AC715076AF715076AG71

    18.018.018.0

    11.516.521.5

    200030004000

    ooo

    ooo

    ooo

    ooo

    50.050.050.0

    oxx

    xox

    xxo

    xoo

    11.04.52.5

    5100AC715100AF715100AG715100AK71

    10.010.010.010.0

    6.29.212.518.0

    2000300040006000

    xxoo

    xooo

    oooo

    oooo

    30.542.550.050.0

    xxxx

    xoox

    xoxo

    xxoo

    11.56.54.52.5

    5101AC715101AF715101AG71

    15.015.015.0

    9.414.517.5

    200030004000

    xoo

    ooo

    ooo

    ooo

    42.550.050.0

    oxx

    oox

    xxo

    xoo

    9.54.52.5

    5102AA715102AC715102AF71

    27.027.027.0

    9.916.525.0

    120020003000

    xoo

    ooo

    ooo

    ooo

    42.550.050.0

    xxx

    xox

    xoo

    xxo

    11.56.52.5

    1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    Feed modules (VS)04.971.2 Current controller settings 03.96

  • VS

    07.94

    VS/1-9 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-6 adaptation table for feed module 25/50 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT... Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5103AC715103AF715103AG71

    19.019.019.0

    12.017.523.0

    200030004000

    ooo

    ooo

    ooo

    ooo

    50.050.050.0

    xxo

    xxx

    ooo

    oox

    8.02.52.0

    5104AA715104AC71

    37.037.0

    14.022.5

    12002000

    oo

    oo

    oo

    oo

    50.050.0

    xo

    xo

    xx

    xo

    11.54.0

    5106AA71 45.0 17.0 1200 o o o o 50.0 x x o x 8.0

    5108AA71 55.0 20.5 1200 o o o o 50.0 x o o x 6.5

    5132AA71 60.0 22.5 1200 o o o o 50.0 o x o x 7.5

    1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    Feed modules (VS)04.97 1.2 Current controller settings03.96

  • 07.94

    VS/1-10 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-7 Adaptation table for feed module 40/80 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    4101SK714101SN71

    20.020.0

    33.039.0

    60008000

    oo

    oo

    oo

    oo

    80.080.0

    ox

    xo

    oo

    oo

    2.01.0

    4102SG71 33.0 35.0 4000 o o o o 80.0 o o x o 4.05046AK71 2.6 4.7 6000 o x o x 24.0 x x o o 2.5

    5062AK71 2.2 3.9 6000 o x x x 19.2 o o x o 4.0

    5064AF715064AG715064AK71

    4.54.54.5

    4.15.58.0

    300040006000

    ooo

    xoo

    xox

    xxo

    19.228.840.0

    xxo

    xoo

    oox

    xxo

    8.06.54.0

    5066AC715066AF715066AG715066AK71

    6.56.56.56.5

    3.96.07.911.6

    2000300040006000

    oooo

    xoox

    xoxo

    xxoo

    19.228.240.054.4

    xxox

    xxoo

    xoox

    xxxo

    11.58.06.04.5

    5070AK71 3.0 5.3 6000 o x o x 24.0 x o o x 6.5

    5071AF715071AG715071AK71

    4.54.54.5

    4.35.27.9

    300040006000

    oxo

    ooo

    xox

    xxo

    20.827.240.0

    oxx

    oxo

    xox

    xxo

    9.58.04.5

    5072AC715072AF715072AG715072AK71

    10.010.010.010.0

    6.19.112.017.5

    2000300040006000

    oooo

    ooxo

    oxoo

    xooo

    28.840.054.480.0

    xooo

    xoxx

    xxox

    xxxo

    11.59.57.55.5

    5073AC715073AF715073AG715073AK71

    7.07.07.07.0

    4.36.48.112.5

    2000300040006000

    oxoo

    oxox

    xxxo

    xooo

    20.831.240.054.4

    xxxx

    xxox

    xooo

    xxxo

    11.58.06.52.5

    5074AC715074AF715074AG715074AK715074SG715074SK71

    14.014.014.014.016.016.0

    8.513.016.525.019.028.0

    200030004000600040006000

    oooooo

    oxoooo

    xooooo

    oooooo

    40.054.480.080.080.080.0

    xoxxox

    xxoxox

    xooooo

    xxxoxo

    11.57.56.52.56.02.5

    5076AC715076AF715076AG715076AK715076SG71

    18.018.018.018.020.5

    11.516.521.532.024.5

    20003000400060004000

    xxooo

    xoooo

    ooooo

    ooooo

    48.868.080.080.080.0

    oxxoo

    xooxo

    xoxox

    xxooo

    11.06.54.52.04.0

    5100AC715100AF715100AG715100AK71

    10.010.010.010.0

    6.29.212.518.0

    2000300040006000

    xooo

    xoxo

    xxoo

    oooo

    31.240.054.480.0

    xxoo

    xoxo

    xoxx

    xxoo

    11.56.55.54.0

    5101AC715101AF715101AG715101AK71

    15.015.015.015.0

    9.414.517.526.5

    2000300040006000

    oooo

    oxoo

    xooo

    oooo

    40.054.480.080.0

    xoxo

    xxox

    oxxo

    xooo

    8.05.54.52.0

    1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    1.2 Current controller settingsFeed modules (VS)

    03.96

  • VS

    07.94

    VS/1-11 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-7 Adaptation table for feed module 40/80 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5102AA715102AC715102AF715102AG71

    27.027.027.027.0

    9.916.525.031.5

    1200200030004000

    oooo

    oooo

    xooo

    oooo

    40.080.080.080.0

    xoox

    xoox

    xxxo

    xxoo

    11.59.54.02.5

    5103AC715103AF715103AG71

    19.019.019.0

    12.017.523.0

    200030004000

    ooo

    xoo

    ooo

    ooo

    54.480.080.0

    xox

    xox

    ooo

    xxo

    8.06.02.5

    5104AA715104AC715104AF71

    37.037.037.0

    14.022.534.0

    120020003000

    ooo

    xoo

    ooo

    ooo

    54.480.080.0

    xxx

    xox

    xoo

    xxo

    11.56.52.5

    5106AA715106AC71

    45.045.0

    17.026.8

    12002000

    oo

    oo

    oo

    oo

    80.080.0

    xo

    xx

    xx

    xo

    11.55.5

    5108AA715108AC71

    55.055.0

    20.532.5

    12002000

    oo

    oo

    oo

    oo

    80.080.0

    xx

    xo

    xx

    xo

    11.54.5

    5132AA715132AC715132SA71

    60.060.070.0

    22.535.526.0

    120020001200

    ooo

    ooo

    ooo

    ooo

    80.080.080.0

    xxx

    xox

    xxx

    xox

    11.54.511.5

    5134AA715134SA71

    75.090.0

    28.034.0

    12001200

    oo

    oo

    oo

    oo

    80.080.0

    oo

    oo

    xx

    xx

    9.59.5

    5136AA71 85.0 31.5 1200 o o o o 80.0 o x o x 7.5

    5138AA71 105.0 39.0 1200 o o o o 80.0 o o o x 6.0

    1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    1.2 Current controller settingsFeed modules (VS)

    03.96

  • VS

    07.94

    VS/1-12 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-8 Adaptation table for feed module 80/160 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    4101SK714101SN71

    20.020.0

    33.039.0

    60008000

    oo

    oo

    oo

    oo

    160.0160.0

    xx

    ox

    xo

    oo

    4.52.5

    4102SG714102SK71

    33.033.0

    35.047.0

    40006000

    oo

    oo

    oo

    oo

    160.0160.0

    xx

    xo

    ox

    xo

    8.04.5

    4104SG714104SK71

    45.045.0

    46.060.0

    40006000

    oo

    oo

    oo

    oo

    160.0160.0

    ox

    xx

    xo

    oo

    5.52.5

    4106SG71 59.0 56.0 4000 o o o o 160.0 x o x o 4.55064AK71 4.5 8.0 6000 o o x x 41.6 x o x o 4.5

    5066AG715066AK71

    6.56.5

    7.911.6

    40006000

    oo

    xo

    xo

    xx

    38.457.6

    ox

    oo

    ox

    xo

    6.04.5

    5071AK71 4.5 7.9 6000 o x x x 38.4 x o x o 4.5

    5072AF715072AG715072AK71

    10.010.010.0

    9.112.017.5

    300040006000

    ooo

    ooo

    xox

    xxo

    41.657.680.0

    oxo

    oxx

    xox

    xxo

    9.58.05.5

    5073AG715073AK71

    7.07.0

    8.112.5

    40006000

    oo

    ox

    xx

    xo

    41.665.5

    xo

    oo

    ox

    xo

    6.54.0

    5074AC715074AF715074AG715074AK715074SG715074SK71

    14.014.014.014.016.016.0

    8.513.016.525.019.028.0

    200030004000600040006000

    oooxox

    oxoxox

    xxxoxo

    xooooo

    41.665.680.097.680.097.0

    xxxxox

    xxoxxx

    xoooxo

    xxxooo

    11.58.06.52.55.52.5

    5076AC715076AF715076AG715076AK715076SG715076SK71

    18.018.018.018.020.520.5

    11.516.521.532.024.536.0

    200030004000600040006000

    oxoooo

    xoxoxo

    oxoooo

    xooooo

    48.073.6108.8160.0108.8160.0

    ooxooo

    oxooxo

    xooxxx

    xxxooo

    9.57.56.54.05.54.0

    5100AF715100AG715100AK71

    10.010.010.0

    9.212.518.0

    300040006000

    xxo

    xxo

    oxx

    xoo

    46.462.480.0

    xxo

    xoo

    oox

    xxo

    8.06.54.0

    5101AC715101AF715101AG715101AK71

    15.015.015.015.0

    9.414.517.526.5

    2000300040006000

    ooox

    oxoo

    xxxo

    xooo

    41.665.680.0136.0

    oxxo

    oooo

    xoxx

    xxoo

    9.56.54.54.0

    5102AA715102AC715102AF715102AG715102SF715102SG71

    27.027.027.027.034.034.0

    9.916.525.031.531.539.5

    120020003000400030004000

    xooooo

    xoxoxo

    oxoooo

    xooooo

    46.480.0108.8160.0108.8160.0

    xoooxx

    xoxxoo

    xxxxxx

    xxoooo

    11.59.55.55.54.54.5

    5103AC715103AF715103AG71

    19.019.019.0

    12.017.523.0

    200030004000

    ooo

    oox

    oxo

    xoo

    57.680.0108.8

    xox

    xoo

    oox

    xxo

    8.06.04.5

    1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    1.2 Current controller settingsFeed modules (VS)

    03.96

  • VS

    07.94

    VS/1-13 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-8 Adaptation table for feed module 80/160 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5104AA715104AC715104AF715104SF71

    37.037.037.048.0

    14.022.534.044.0

    1200200030003000

    xooo

    xxoo

    xooo

    oooo

    62.4108.8160.0160.0

    xoxo

    xoox

    xxox

    xxxo

    11.59.56.55.5

    5106AA715106AC715106AF715106SF71

    45.045.045.057.0

    17.026.842.554.0

    1200200030003000

    oooo

    oxoo

    xooo

    oooo

    80.0108.0160.0160.0

    xoxo

    xxoo

    xoxx

    xxoo

    11.57.54.54.0

    5108AA715108AC715108AF71

    55.055.055.0

    20.532.550.5

    120020003000

    ooo

    ooo

    xoo

    ooo

    80.0160.0160.0

    xoo

    xoo

    xxx

    xxo

    11.59.54.0

    5132AA715132AC715132AF715132SA715132SC715132SF71

    60.060.060.070.070.070.0

    22.535.547.526.041.055.5

    120020003000120020003000

    oooooo

    xooxoo

    oooooo

    oooooo

    108.8160.0160.0108.8160.0160.0

    xxoxxx

    xxxxxx

    xoxxox

    xxoxxo

    11.58.05.511.58.05.5

    5134AA715134AC715134SA715134SC71

    75.075.090.090.0

    28.047.034.056.0

    1200200012002000

    oooo

    xoxo

    oooo

    oooo

    108.8160.0108.8160.0

    xxxx

    xoxo

    xoxo

    xoxx

    11.56.511.56.5

    5136AA715136AC715136SA715136SC71

    85.085.0110.0110.0

    31.547.541.061.5

    1200200012002000

    xoxo

    oooo

    oooo

    oooo

    136.0160.0136.0160.0

    xxxx

    xoxo

    xoxo

    xxxo

    11.56.511.56.5

    5138AA715138SA71

    105.0140.0

    39.052.0

    12001200

    oo

    oo

    oo

    oo

    160.0160.0

    xx

    xx

    xx

    xx

    11.511.5

    1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    1.2 Current controller settingsFeed modules (VS)

    03.96

  • VS

    07.94

    VS/1-14 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-9 Adaptation table for feed module 100/200 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    4101SK714101SN71

    20.020.0

    33.039.0

    60008000

    ox

    xo

    oo

    oo

    136.0170.0

    xx

    xx

    oo

    oo

    2.52.0

    4102SG714102SK71

    33.033.0

    35.047.0

    40006000

    xo

    oo

    oo

    oo

    170.0200.0

    oo

    ox

    xx

    xo

    9.55.5

    4104SG714104SK71

    45.045.0

    46.060.0

    40006000

    oo

    oo

    oo

    oo

    200.0200.0

    xx

    ox

    oo

    xo

    6.52.5

    4106SG71 59.0 56.0 4000 o o o o 200.0 o x x o 5.55066AK71 6.5 11.6 6000 o x o x 60.0 x o x o 4.5

    5072AG715072AK71

    10.010.0

    12.017.5

    40006000

    oo

    xx

    ox

    xo

    60.082.0

    xo

    xx

    ox

    xo

    8.05.5

    5073AK71 7.0 12.5 6000 o x o x 60.0 o o x o 4.0

    5074AF715074AG715074AK715074SG715074SK71

    14.014.014.016.016.0

    13.016.525.019.028.0

    30004000600040006000

    ooooo

    xxoxo

    oxxxx

    xoooo

    60.082.0100.082.0100.0

    xxxox

    xoxox

    ooooo

    xxoxo

    8.06.52.56.02.5

    5076AC715076AF715076AG715076AK715076SG715076SK71

    18.018.018.018.020.520.5

    11.516.521.532.024.536.0

    200030004000600040006000

    oxoooo

    oxoxox

    xxxoxo

    xooooo

    52.078.0100.0136.0100.0136.0

    xxoxxx

    xxxxox

    xoxoxo

    xxoooo

    11.58.05.52.54.52.5

    5100AF715100AG715100AK71

    10.010.010.0

    9.212.518.0

    300040006000

    xox

    xxo

    xox

    xxo

    46.060.092.0

    xox

    xoo

    oox

    xxo

    8.06.04.5

    5101AC715101AF715101AG715101AK71

    15.015.015.015.0

    9.414.517.526.5

    2000300040006000

    xoxo

    xxox

    xoxo

    xxoo

    46.060.092.0136.0

    oooo

    oooo

    xoox

    xxxo

    9.56.06.04.0

    5102AA715102AC715102AF715102AG715102SF715102SG71

    27.027.027.027.034.034.0

    9.916.525.031.531.539.5

    120020003000400030004000

    xxooxo

    xxoxxx

    xxxooo

    xooooo

    46.078.0100.0136.0122.0136.0

    xoxxoo

    xoooxo

    xxxxxx

    xxoooo

    11.59.54.54.55.54.0

    5103AC715103AF715103AG71

    19.019.019.0

    12.017.523.0

    200030004000

    oxx

    xox

    oxo

    xoo

    60.092.0122.0

    oxo

    oox

    xox

    xxo

    9.56.55.5

    5104AA715104AC715104AF715104SF71

    37.037.037.048.0

    14.022.534.044.0

    1200200030003000

    oooo

    xoxx

    oxoo

    xooo

    60.0100.0136.0136.0

    xxox

    xxxo

    xoxx

    xxoo

    11.58.05.54.5

    5106AA715106AC715106AF715106SF71

    45.045.045.057.0

    17.026.842.554.0

    1200200030003000

    xxoo

    xxoo

    xooo

    oooo

    78.0122.0200.0200.0

    xxox

    xxxo

    xoxx

    xxoo

    11.58.05.54.5

    1) The specified value is the maximum permisisble current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    1.2 Current controller settingsFeed modules (VS)

    03.96

  • VS

    07.94

    VS/1-15 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Table 1-9 Adaptation table for feed module 100/200 A

    Servomotor Current limit 1) Current controller gain

    1FT M [Nm] I [A] n t d [RPM]Contacts

    I [A]Contacts

    Kp(I)1FT Mo [Nm] Io [A] nrated [RPM] 2 3 4 5 Imax [A] 6 7 8 9 K (I)

    5108AA715108AC715108AF71

    55.055.055.0

    20.532.550.5

    120020003000

    xoo

    oxo

    xoo

    ooo

    92.0136.0200.0

    xxx

    xxo

    xox

    xxo

    11.58.04.5

    5132AA715132AC715132AF715132SA715132SC715132SF71

    60.060.060.070.070.070.0

    22.535.547.526.041.055.5

    120020003000120020003000

    oxooxo

    oooooo

    xooxoo

    oooooo

    100.0170.0200.0100.0170.0200.0

    xoxxox

    xooxoo

    xxoxxo

    xxxxxx

    11.59.56.511.59.56.5

    5134AA715134AC715134SA715134SC71

    75.075.090.090.0

    28.047.034.056.0

    1200200012002000

    xoxo

    xoxo

    oooo

    oooo

    122.0200.0122.0200.0

    xxxx

    xxxx

    xoxo

    xxxx

    11.58.011.58.0

    5136AA715136AC715136SA715136SC71

    85.085.0110.0110.0

    31.547.541.061.5

    1200200012002000

    oooo

    xoxo

    oooo

    oooo

    136.0200.0136.0200.0

    xxxx

    xxxx

    xoxo

    xxxx

    11.58.011.58.0

    5138AA715138SA71

    105.0140.0

    39.052.0

    12001200

    xx

    oo

    oo

    oo

    170.0170.0

    xx

    xx

    xx

    xx

    11.511.5

    1) The specified value is the maximum permissible current of the particular power module motor combination. It may benecessary to reduce the specified value depending on the driven mechanical system.

    1.2 Current controller settingsFeed modules (VS)

    03.96

  • VS

    07.94

    VS/1-16 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    1.2 Current controller settingsFeed modules (VS)

  • VS

    07.94

    VS/2-17 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Speed controller optimization

    The additional smoothing functions in the speed controller loop (damping me-chanical resonance effects) are described in Section 3. Proceed as followswhen optimizing the speed controller:4. Tachometer adjustment5. Gain Kp6. Integral action time TN7. Adaptation TN (if required)8. Icomponent limiting (if required)9. Drift compensation (offset)The unit must be poweredup to optimize the speed controller Sections 2.1, 2.2,2.3 and 2.8. Therefore please refer to Section 7 Poweringup.

    The potentiometer scale divisions (in the setting tables) are defined as follows:

    8 9/10

    76

    54

    32 0/1

    5

    123

    4

    987

    6

    0

    10

    The setting shown in the diagram cor-responds to 7 scale divisions.

    Feed modules (VS)2 Speed controller optimization

    2

  • VS

    07.94

    VS/2-18 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    2.1 Tachometer adjustmentFor motors with tachometer voltages 16.5 V, it is necessary to also proceedaccording to Section 1.1.

    Potentiometer Setting range

    T 0.7 nrated 2.2 nact N 2.2 nrated

    0 1 2 3 4 5 6 7 8 910

    Tachometer potentiometer (scaled)

    0.6

    0.8

    1

    1.2

    1.4

    1.6

    1.8

    2

    2.2 nact N/ nact

    Fig. 2-1 Tachometer adjustment

    Extending the setting range using R3 and R10 (only for the userfriendlyinterface).

    Function Component Mountednact N > 0.7 nrated Increase R3 0 (as supplied)nact N < 2.2 nrated Mount R10 Open (as supplied)

    2.2 Setting the proportional gain Kp withoutadaptation

    The proportional gain Kp of the speed controller can be set using potentiometerKp. The range can be extended if required using the fixed resistor R50 (only forthe userfriendly interface ; R50 = 68 k (as supplied)). The gain, set using the Kp potentiometer is additionally influenced by the settingof potentiometer TN.

    Feed modules (VS)2.1 Tachometer adjustment 04.97

  • VS

    07.94

    VS/2-19 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    Kp

    0 1 2 3 4 5 6 7 8 910

    Potentio-meter TN

    Center

    Lefthandendstop

    Righthand endstop

    Setting of pot. Kp

    0

    20

    40

    60

    80

    100

    120

    140

    160170

    Fig. 2-2 Proportional gain Kp as a function of the Kp and TN potentiometers

    2.3 Setting the integral action time TN without adaptation

    The speed controller integral action time is set using potentiometer TN; therange can be, if required, extended using C2 (only for the userfriendly inter-face).

    TN in ms

    Setting of pot. TN

    0

    10

    20

    30

    4045

    0 1 2 3 4 5 6 7 8 9 10

    Fig. 2-3 Integral action time TN as a function of potentiometer TN

    Feed modules (VS)04.97 2.3 Setting the integral action time TN without adaptation

  • VS

    07.94

    VS/2-20 Siemens AG 1997 All Rights reserved

    SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    2.4 Integral action time with adaptation (if required)Adaptation is activated and preset via R34 (only the userfriendly interface),and S3.5 (S6.5 for a 2nd axis) for the standard interface.

    R34 = openR34 = mounted

    Adaptation inactive (as supplied)Adaptation operates acc. to the following diagrams

    TN

    TNadapt

    Potentiometer TNR34 + potentiometer ADAPT

    nx2 nx1

    nxAdaptationineffective

    Adaptationfully effective

    Transitionrange

    Fig. 2-4 Integral action time dependency

    nx = nsetp. + nact.

    0.9

    0.7

    0.5

    0.3

    0.10

    TNadapt/TN

    R34 = 10 kR34 = 0 or standardinterface

    Setting of the ADAPT potentiometer

    0 1 2 3 4 5 6 7 8 910

    Fig. 2-5 Dependency of adaptation TN

    Feed modules (VS)04.972.4 Integral action time with adaptation (if required)

  • VS

    07.94

    VS/2-21 Siemens AG 1997 All Rights reserved SIMODRIVE 611A Installation and StartUp Guide/IAA/04.97 Edition

    2.5 Proportional gain with adap