8
FLEXIBILITY AND OPTIONS TO SUPPORT YOUR ANALYTICAL NEEDS The flexibility and robustness of the Waters ® ACQUITY UPLC ® H-Class System make it the ideal choice for sustaining legacy HPLC methods, as well as developing and supporting UPLC ® methods. There are also a wide variety of system accessories designed to help meet your method requirements while maximizing productivity. DETECTION OPTIONS PDA, PDA eλ, TUV, ELS, FLR, RI, MS COLUMN HEATER OPTIONS Column Heater (CH-A) Column Heater 30 cm (CH30-A) Column Heater/Cooler 30 cm (CHC) Column Manager (CM-A) Column Manager Auxilliary (CM-AUX) SAMPLE MANAGER - FLOW THROUGH NEEDLE (SM - FTN) Sample Organizer (extended capacity) QUATERNARY SOLVENT MANAGER (QSM) ACQUITY UPLC H-Class and ACQUITY UPLC H-Class Bio System Accessories

Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

Embed Size (px)

Citation preview

Page 1: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

FLEXIBILIT Y AND OPT IONS TO SUP PORT YOUR ANALYT ICAL NEEDS

The flexibility and robustness of the Waters® ACQUITY UPLC® H-Class System make it the

ideal choice for sustaining legacy HPLC methods, as well as developing and supporting

UPLC® methods. There are also a wide variety of system accessories designed to help meet

your method requirements while maximizing productivity.

DETECTION OPTIONS

PDA, PDA eλ, TUV, ELS, FLR, RI, MS

COLUMN HEATER OPTIONS

Column Heater (CH-A)

Column Heater 30 cm (CH30-A)

Column Heater/Cooler 30 cm (CHC)

Column Manager (CM-A)

Column Manager Auxilliary (CM-AUX)

SAMPLE MANAGER - FLOW THROUGH NEEDLE (SM - FTN)

Sample Organizer (extended capacity)

QUATERNARY SOLVENT MANAGER (QSM)

Acquity uplc H-class and Acquity uplc H-class Bio System Accessories

Page 2: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

2

QUATERNARY SOLVENT MANAGER ACCESSORIES

The ACQUITY UPLC H-Class QSM dynamically blends up to four solvents

in any proportion, eliminating the time and potential error of pre-mixing

mobile phases. With an optional, fully integrated solvent select valve,

the system capacity can be expanded, accessing up to nine solvents to

significantly increase the system’s ability to screen multiple solvents when

developing methods.

QUATERNARY SOLVENT MANAGER ACCESSORIES

PART NUMBER ITEM DESCRIPTION

205000731 Particulate filter, 22 µL Used in place of standard 100-µL mixer when lowest possible dwell volume is desired; not recommended for use with UV detection

700005119 Mixer/filter, 100 µL Standard mixer (packed bead mixer, zirconia beads)

205000719 Mixer/filter, 250 µL Additional mixing for low-UV wavelength applications utilizing strong UV-absorbing mobile phases (i.e., TFA)(packed bead mixer, zirconia beads)

700005162 i2 Valve cartridge assembly (inlet check valve)

Inlet check valves (electronically controlled) designed to improve robustness as well as enable faster system priming and start-up times (standard)

700005164 Outlet check valve Dual ball and seat passive check valve

700003616 Mobile phase bottle filters, Package of 7, SS

General purpose, critically clean stainless steel solvent filters that are placed in the mobile phase bottle

700005173 GPV particulate filter, Package of 4, SS

Critically clean stainless steel particulate filters for the Gradient Proportioning Valve (GPV)

205000661 Hexane/THF compatibility kit Enables ACQUITY UPLC H-Class System to accommodate mobile phase containing a high content of THF and/or Hexane

205000660 Solvent select valve Provides additional 6 solvent choices; plumbed into line D, extending solvent choice to A, B, C, and D1- 6; fully integrated into QSM (includes valve cartridge)

700005408 Solvent select valve cartridge Solvent select valve (valve cartridge only) for use with the solvent select valve (205000660)

201000233 Preventative Maintenance (PM) Kit, QSM

Includes all necessary components to perform regular PM of the QSM

BIO-QUATERNARY SOLVENT MANAGER ACCESSORIESPART NUMBER ITEM DESCRIPTION

700005258 Mixer/filter, 100-µL bio-inert Standard mixer (packed bead mixer, zirconia beads); all wetted materials are bio-inert

205000737 Mixer/filter, 250-µL bio-inert Additional mixing for low-UV wavelength applications utilizing strong UV-absorbing mobile phases (i.e., TFA)(packed bead mixer, zirconia beads); all wetted materials are bio-inert

700005414 i2 Valve cartridge assembly (inlet check valve) bio-inert

Inlet check valves (electronically controlled) designed to improve robustness as well as enable faster system priming and start-up times (bio-inert)

700005415 Outlet check valve, bio-inert Dual ball and seat passive check valve (bio-inert)

700005378 Mobile phase bottle filters, Pkg. of 7, Ti

Titanium solvent filters that are placed in the mobile phase bottle

700005419 GPV particulate filter, Pkg. of 4, Ti Titanium particulate filters for the Gradient Proportioning Valve (GPV)

205000660 Solvent select valve Provides additional 6 solvent choices; plumbed into line D, extending solvent choice to A, B, C, and D1- 6; fully integrated into QSM (must order separate bio-inert valve cartridge (700005423))

700005423 Solvent select valve cartridge, bio-inert

Bio-inert solvent select valve (valve cartridge only) for use with the solvent select valve (205000660)

201000244 Preventative Maintenance (PM) Kit, bio-QSM

Includes all necessary components to perform regular PM of the bio-QSM

205000800 Hexane/THF compatibility kit Enables ACQUITY UPLC H-Class Bio System to accommodate mobile phase containing a high content of THF and/or Hexane

Page 3: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

3

SAMPLE MANAGER - FTN AND SAMPLE ORGANIZER ACCESSORIES

The ACQUITY UPLC H-Class SM - FTN delivers exceptional sample recovery through highly precise and

accurate injections. Its ultra-low-dispersion design minimizes peak width, leading to a highly efficient

transfer of the sample onto the head of the column while minimizing carryover.

The ACQUITY UPLC Sample Organizer (SO) extends the level of automation and sample processing

throughput of the ACQUITY UPLC H-Class System. The SO supports a wide range of plates and vial

holders, significantly increasing the available sample capacity to: 19 microtiter plates, 9 intermediate

height plates (or 2-mL vial holders), or 6 deep well plates (or 4-mL vial holders).

SAMPLE MANAGER - FTN ACCESSORIES

PART NUMBER ITEM DESCRIPTION

700005215 15-µL needle, SS Standard needle used on the SM - FTN, stainless steel

700005279 30-µL needle, SS Use to reduce cycle times for larger extension loops

430002012 50-µL extension loop Increases the available injection volume up to 50 µL; must be paired with a 100-µL metering syringe (700002570)

430002011 100-µL extension loop Increases the available injection volume up to 100 µL; must be paired with a 250-µL metering syringe (410001347)

430002007 250-µL extension loop Increases the available injection volume up to 250 µL must be paired with a 500-µL metering syringe (410001647)

410001348 50-µL metering syringe Default metering syringe shipped with SM - FTN; metering syringe should be at least 2X the sample volume

700002570 100-µL metering syringe Metering syringe should be at least 2X the sample volume

410001347 250-µL metering syringe Metering syringe should be at least 2X the sample volume

410001647 500-µL metering syringe Metering syringe should be at least 2X the sample volume

405003743 48-well, 2-mL vial holder Auto-sampler vial holder tray for standard 2-mL vials

405003742 24-well, 4-mL vial holder Auto-sampler vial holder tray for large 4-mL vials

405003740 24-well, 1.5-mL tube holder Auto-sampler tube holder tray for 1.5-mL test tubes

405003741 48-well, 0.65-mL tube holder Auto-sampler tube holder tray for 0.65-mL centrifuge tubes

201000234 H-Class SM - FTN Preventative Maintenance (PM) Kit

Includes all necessary components to perform regular PM of the SM - FTN

700005762 100-µL Mixer Optional mixer to aid in the transfer of legacy HPLC methods

BIO-SAMPLE MANAGER - FTN ACCESSORIESPART NUMBER ITEM DESCRIPTION

700005421 15-µL needle, MP35N (bio-inert) Bio-inert needle used on the SM - FTN, MP35N

430002591 50-µL extension loop, MP35N (bio-inert)

Increases the available injection volume up to 50 µL; must be paired with a 100-µL metering syringe (700002570); bio-inert

430002625 100-µL extension loop, MP35N (bio-inert)

Increases the available injection volume up to 100 µL; must be paired with a 250-µL metering syringe (410001347); bio-inert

430002630 250-µL extension loop, MP35N (bio-inert)

Increases the available injection volume up to 250 µL; must be paired with a 500-µL metering syringe (410001647); bio-inert

430002585 1000-µL extension loop, MP35N (bio-inert)

Increases the available injection volume up to 1000 µL; must be paired with a 500-µL metering syringe (410001647); bio-inert

201000201 Bio SM - FTN Preventative Maintenance (PM) Kit

Includes all necessary components to perform regular PM of the bio SM - FTN

SAMPLE ORGANIZER AND ACCESSORIESPART NUMBER ITEM DESCRIPTION

176015040 ACQUITY UPLC Sample Organizer

Extends the level of sample capacity of the ACQUITY UPLC H-Class System to 19 microtiter plates, or 9 intermediate height plates (or 2-mL vial holders), 6 deep well plates (or 4-mL vial holders); ships with 9 shelves

700005778 Additional SO shelf kit, Qty 5 Additional 5 shelves for the sample organizer

205000565 External pneumatic source kit For use if SO is intended to be connected to an external pneumatic source

Page 4: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

4

COLUMN MANAGEMENT

PART NUMBER ITEM DESCRIPTION

186015042 Column Heater with active pre-heating (CH-A)

Accommodates a single column, up to 150 mm in length between 1.0 - 4.6 mm I.D.; temperature range 5 °C above ambient to 90 °C, settable in 0.1 °C increments

176015046 30-cm Column Heater with active pre-heating (CH30-A)

Accommodates a single column, up to 300 mm in length between 2.1 - 4.6 mm I.D.; temperature range 5 °C above ambient to 90 °C, settable in 0.1 °C increments

186015011 30-cm Column Heater/Cooler (30-cm CHC)

Accommodates a single column up to 300 mm in length between 2.1 - 7.8 mm I.D.; temperature ranges between 4 - 65 °C (This unit does NOT have active pre-heating; requires ACQUITY UPLC H-Class compatibility kit (205000761))

176015043 Column Manager with active pre-heating (CM-A)

Accommodates 2 columns up to 150 mm in length or 4 columns up to 50 mm in length, between 2.1 - 4.6 mm I.D.; two independent heat/cool zones with temperature ranges between 4 - 90 °C

176015044 Column Manager (CM-A) and a Single-Auxiliary Column Manager (CM-Aux) with active pre-heating

Accommodates 4 columns up to 150 mm in length between 2.1 - 4.6 mm I.D.; four independent heat/cool zones with temperature ranges between 4 - 90 °C

176015045 Column Manager (CM-A) and a Two-Auxiliary Column Managers (CM-Aux) with active pre-heating

Accommodates 6 columns up to 150 mm in length between 2.1 - 4.6 mm I.D.; six independent heat/cool zones with temperature ranges between 4 - 90 °C

176015048 Auxiliary Column Manager (CM-Aux), positions 3 & 4

Intended as an add-on for a system with a pre-existing CM-A unit; cannot be used independent from a CM-A unit

176015049 Auxiliary Column Manager (CM-Aux), positions 5 & 6

Intended as an add-on for a system with a pre-existing CM-A unit as well as a pre-existing CM-Aux unit; cannot be used independent from a CM-A unit

BIO-INERT COLUMN MANAGEMENT PART NUMBER ITEM DESCRIPTION

176015059 Bio-Inert 30-cm Column Heater with active pre-heating (CH30-A)

Accommodates a single column, up to 300 mm in length between 2.1- 4.6 mm I.D.; temperature range 5 °C above ambient to 90 °C, settable in 0.1 °C increments; bio-inert fluidic path

176015056 Bio-Inert Column Manager with active pre-heating (Bio CM-A)

Accommodates 2 columns up to 150 mm in length or 4 columns up to 50 mm in length, between 2.1- 4.6 mm I.D.; two independent heat/cool zones with temperature ranges between 4 - 90 °C; bio-inert fluidic path

176015057 Bio-Inert Column Manager (Bio CM-A) and a Single Auxiliary Column Manager (Bio CM-Aux) with active pre-heating

Accommodates 4 columns up to 150 mm in length between 2.1- 4.6 mm I.D.; four independent heat/cool zones with temperature ranges between 4 - 90 °C; bio-inert fluidic path

176015058 Bio-Inert Column Manager (Bio CM-A) and a Two Auxiliary Column Managers (Bio CM-Aux) with active pre-heating

Accommodates 6 columns up to 150 mm in length between 2.1- 4.6 mm I.D.; six independent heat/cool zones with temperature ranges between 4 - 90 °C; bio-inert fluidic path

176015052 Bio-Inert Auxiliary Column Manager (Bio CM-Aux), positions 3&4

Intended as an add-on for a system with a pre-existing Bio CM-A unit; cannot be used independent from a Bio CM-A unit; bio-inert fluidic path

176015053 Bio-Inert Auxiliary Column Manager (Bio CM-Aux), positions 5&6

Intended as an add-on for a system with a pre-existing Bio CM-A unit as well as a pre-existing Bio CM-Aux unit; cannot be used independent from a Bio CM-A unit; bio-inert fluidic path

COLUMN MANAGEMENT OPTIONS AND ACCESSORIES

The ACQUITY UPLC Column Heaters and Managers feature active solvent pre-heating to ensure consistent thermal performance from

system-to-system. These intelligent devices enable the temperature of the mobile phase to match the set temperature of the column,

while significantly minimizing dispersion, thus positively impacting the separation performance achievable by the column.

Page 5: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

5

COLUMN MANAGEMENT ACCESSORIES PART NUMBER ITEM SUPPORTED COLUMN MANAGERS DESCRIPTION

205000730 Active pre-heater (APH), SS, 12.5” CH-A, CM-A, CH30-A Standard active pre-heater used with CH-A

205000774 Active pre-heater (APH), SS, 18.5” CM-A, CM-Aux Active pre-heater, stainless steel

205000776 Active pre-heater (APH), SS, 23.5” CM-A, CM-Aux, CH30-A Active pre-heater, stainless steel

205000764 Two APH, SS CM-A Contains two active pre-heaters for use with the CM-A

205000765 Four APH, SS CM-A, CM-Aux Contains four active pre-heaters for use with the CM-A

205000767 Six APH, SS CM-A, CM-Aux Contains six active pre-heaters for use with the CM-A

205000489 Column stabilizer for 50-mm columns CH-A Passive mobile phase pre-heater to support legacy methods, accommodates columns <100 mm in length

205000494 Column stabilizer for 150-mm columns CH-A Passive mobile phase pre-heater to support legacy methods, accommodates columns <150 mm in length

205000761 30-cm Column Heater/Cooler compatibility kit

30-cm CHC Includes power cord and appropriate connective tubing to interface 30-cm CHC to ACQUITY UPLC H-Class and ACQUITY UPLC H-Class Bio systems

205000726 Column Heater extension kit for MS CH-A Includes mounting bracket and drip trays required for interfacing CH-A, in its extended position, with an MS source

700005438 Switching valve cartridge (one), SS CM-A 9-port switching valve cartridge pod, stainless steel

205000768 Switching valve cartridges (two), SS CM-A Two, 9-port switching valve cartridge pods, stainless steel

205000547 UPLC flow restrictor CH-A, CM-A, CM-Aux For use in applications where additional backpressure is needed 40 µm x 14”

BIO-INERT COLUMN MANAGEMENT ACCESSORIES PART NUMBER ITEM SUPPORTED COLUMN MANAGERS DESCRIPTION

205000756 Active pre-heater (APH), MP35N, 12.5” CH-A, CM-A, CH30-A Standard bio-inert active pre-heater

205000775 Active pre-heater (APH), MP35N, 18.5” CM-A, CM-Aux Bio-inert active pre-heater

205000777 Active pre-heater (APH), MP35N, 23.5” CM-A, CM-Aux, CH30-A Bio-inert active pre-heater

205000778 Two APH, MP35N CM-A Contains two bio-inert active pre-heaters for use with the CM-A

205000779 Four APH, MP35N CM-A, CM-Aux Contains four bio-inert active pre-heaters for use with the CM-A/CM-Aux

205000780 Six APH, MP35N CM-A, CM-Aux Contains six bio-inert active pre-heaters for use with the CM-A/CM-Aux

700005461 Switching valve cartridge (single), Ti CM-A Single 9-port switching valve cartridge pod, titanium

205000773 Switching valve cartridge (two), Ti CM-A Two, 9-port switching valve cartridge pod, titanium

Page 6: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

6

ACQUITY UPLC DETECTORS AND ACCESSORIES

Designed to enhance and maintain the separation efficiency of all ACQUITY UPLC Systems, ACQUITY UPLC Detectors enable the analysis

of a wide variety of compounds while delivering exceptional levels of sensitivity. A number of flow cell choices are available to meet

your method requirements. Detector options include: Photodiode Array (PDA), Extended Wavelength PDA (PDA eλ), Tunable UV (TUV),

Fluorescence (FLR), Refractive Index (RI), and Evaporative Light Scattering (ELS).

DETECTORS

PART NUMBER ITEM DESCRIPTION

176015026 ACQUITY UPLC PDA Detector Wavelength range from 190 – 500 nm, with 1.2-nm spectral resolution; data rates up to 80 Hz; linear response across 2.0-AU dynamic range; supports full 3D spectral analysis or multi-wavelength operation simultaneously; includes analytical flow cell of 10-mm path length with 500 nL illuminated volume

176015030 ACQUITY UPLC PDA eλ Detector Wavelength range from 190 – 800 nm, with 1.2-nm spectral resolution; data rates up to 80 Hz; linear response across 2.0-AU dynamic range; supports full 3D spectral analysis or multi-wavelength operation simultaneously; includes analytical flow cell of 10-mm path length with 500 nL illuminated volume

176015028 ACQUITY UPLC TUV Detector Wavelength range from 190 –700 nm; tunable UV, dual-wavelength UV/Vis detector; data rates up to 80 Hz; linear response across 2.5 AU; dynamic range extends to 4.0 AU; includes analytical flow cell of 10-mm path length with 500 nL illuminated volume

176015095 ACQUITY RI Detector Features a thermal design that uses active heating in an insulated oven and a counter-current heat exchanger to ensure that incoming solvent temperature is matched to that of the exiting solvent, delivering stable baselines for repeatable peak integration even at low concentrations; integrated valves allow for automatic purging of the reference side of the flow cell and automated solvent recycling; access to the detector status and all diagnostic information is supported through the Instrument Console

176015027 ACQUITY UPLC ELS Detector Designed to monitor compounds with poor or no UV/Vis response or analytes with poor ionization efficiency in MS; comes preconfigured with low dispersion nebulizer

176015029 ACQUITY UPLC FLR Detector Multi-channel, multi-wavelength fluorescence detector; axially-illuminated flow cell design allows for better light adsorption with minimal dispersion

DETECTOR ACCESSORIES

PART NUMBER ITEM DESCRIPTION

205015017 PDA flow cell, analytical, 10 mm, 500 nL

Standard flow cell used in PDA and PDA eλ. 10 mm path length with 500 nL illuminated volume; 127-µm PEEK interconnect inlet/outlet tubing; included when ordering PDA or PDA eλ detectors

205015036 PDA flow cell, low-dispersion analytical, 10 mm, 500 nL

For use in PDA and PDA eλ. 10 mm path length with 500 nL illuminated volume; 63.5-µm PEEK interconnect inlet/outlet tubing

205015035 PDA flow cell, low-dispersion microbore, 10 mm, 250 nL

For use in PDA and PDA eλ. 10 mm path length with 250 nL illuminated volume; 63.5/ 89-µm PEEK interconnect inlet/outlet tubing

205015005 PDA flow cell, high sensitivity, 25 mm, 2400 nL

For use in PDA and PDA eλ. 25 mm path length with 2400 nL illuminated volume; 62.5-µm PEEK interconnect inlet/outlet tubing

205015006 PDA flow cell, high throughput, 3 mm, 135 nL

For use in PDA and PDA eλ; 3 mm path length with 135 nL illuminated volume; 62.5-µm PEEK interconnect inlet/outlet tubing

205000612 PDA flow cell, stainless steel, 5 mm, 1500 nL

For use in PDA and PDA eλ; 5 mm path length with 1500 nL illuminated volume; stainless steel

205000613 PDA flow cell, titanium, 5 mm, 1500 nL

For use in PDA and PDA eλ; 5 mm path length with 1500 nL illuminated volume; titanium

205015016 TUV flow cell, analytical, 10 mm, 500 nL

Standard flow cell used in the TUV; 10 mm path length with 500 nL illuminated volume; 127-µm PEEK interconnect inlet/outlet tubing; included when ordering TUV detector

205015033 TUV flow cell, low-dispersion analytical, 10 mm, 500 nL

For use with TUV; 10 mm path length with 500 nL illuminated volume; 63.5-µm PEEK interconnect inlet/outlet tubing

205015032 TUV flow cell, low-dispersion microbore, 10 mm, 250 nL

For use with TUV; 10 mm path length with 250 nL illuminated volume; 63.5/ 89-µm PEEK interconnect inlet/outlet tubing

Page 7: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

7

205015018 TUV flow cell, high sensitivity, 25 mm, 2400 nL

For use with TUV; 25 mm path length with 2400 nL illuminated volume; 62.5-µm PEEK interconnect inlet/outlet tubing

205000610 TUV flow cell, stainless steel, 5 mm, 1500 nL

For use with TUV; 5 mm path length with 1500 nL illuminated volume; stainless steel

205000611 TUV flow cell, titanium, 5 mm, 1500 nL

For use with TUV; 5 mm path length with 1500 nL illuminated volume; titanium

205000609 FLR large-volume flow cell For use with FLR; used for high sensitivity analyses (i.e., aflotoxin analysis)

205000500 FLR cuvette and holder cell Enables the ACQUITY UPLC FLR Detector to accommodate a cuvette, allowing the detector to act as a spectrophotometer

205000342 ELS UPLC nebulizer Spare nebulizer for the ACQUITY UPLC ELS Detector; included when ordering ACQUITY UPLC ELS Detector

FITTINGS, TUBING, AND RELATED COMPONENTS

Low-dispersion connections and fittings are a necessity towards achieving and maintaining UPLC performance.

PART NUMBER ITEM DESCRIPTION

700003139 Re-usable high pressure finger tight fittings, 10 – 32

Single high-pressure finger-tight fitting capable of pressures up to 18,000 psi; can accommodate all column types

410003354 Locking, dual thread compression screw

Two-piece gold-plated stainless steel compression screw; replacement for two-piece compression screw on APH (used in conjunction with 700003114); capable of pressures up to 18,000 psi

700002645 Dual thread compression screw, long, pkg. of 10

Gold-plated stainless steel compression screw (used in conjunction with 700002635); capable of pressures up to 18,000 psi

700002634 Dual thread compression screw, short, pkg. of 10

Gold-plated stainless steel compression screw (used in conjunction with 700002635); capable of pressures up to 18,000 psi

410001905 One-piece finger-tight fitting, PEEK 10 – 32, black, pkg. of 10

For use on the low-pressure (outlet) side of the column

700003114 PEEK ferrule, 1/16, pkg. of 10 For use with re-usable high pressure finger-tight fitting (used in conjunction with 410003354); capable of pressures up to 18,000 psi

700002635 Two piece Swagelock ferrule set, pkg. of 10

Two-piece Swagelock ferrule; (used in conjunction with 700002645); capable of pressures up to 18,000 psi

700000991 PEEK compression screw and ferrule with SS lock ring, 1/16, pkg. of 5

Used at bulkhead fitting at detector inlet

700003443 PEEK tubing roll, 0.0025” x 60” (beige)

For use post-column

700003799 PEEK tubing roll, 0.004” x 60” (black) For use post-column

700002636 Union, 0.020 ID, V-Detail Tubing union used for UPLC

700004068 PEEK micro tee For use: (1) When two destructive detectors are configured, (2) when an FLR and a destructive detector are configured, (3) to increase sensitivity in the system by restricting the flow rate range

700002747 Pin plug for UPLC, pkg. of 5 Used for sealing valve positions not in use

700004067 Tubing and fittings kit, multiple detectors

Contains multiple fittings and tubing to support multiple UPLC detectors in multiple stacked configurations

700003170 Multi-tool for high pressure finger-tight fittings

Ferrule removal tool used with 700003139

700001012 PEEK tubing cutter Tubing cutter for custom configurations of PEEK tubing

205000478 Column support clips, pkg. of 10 Used as spacers at fluidic connections to the column for even heat dissipation

Page 8: Acquity uplc H-class and Acquity uplc H-class Bio … flexibility and robustness of the Waters ® ACQUITY UPLC H-Class System make it the ... 410001348 50-µL metering syringe Default

Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com

Waters, T he Science of What’s Possible, Waters Quality Parts, Empower, ACQUITY UPLC, and UPLC are registered trademarks of Waters Corporation. All other trademarks are the property of the respective owners.

©2013 Waters Corporation. Printed in the U.S.A.July 2013 720004680EN LB-IGS

ACQUITY UPLC H-CLASS SYSTEM OPTIONS

Enhance your UPLC system configuration with unique application add-on kits and other ease-of-use options.

PART NUMBER ITEM DESCRIPTION

176000830 ACQUITY UPLC Flex Cart Mobilizes ACQUITY UPLC H-Class Systems to orient close to MS source; adjustable height; self-containing cart provides electrical outlets, supports computer tower, monitor, keyboard, and mouse, and manages fluidic waste containers

176001983 UPLC Local Console Controller (LCC) Hand-held device designed to complement ACQUITY UPLC H-Class Systems within an Empower® Network environment; supported by a LAC/E32 box and mounts directly onto the ACQUITY UPLC Sample Manager - FTN

176002683 Amino Acid Analysis kit for ACQUITY UPLC H-Class

Turn-key application kit required to perform amino acid analysis; compatible with ACQUITY UPLC H-Class and ACQUITY UPLC H-Class Bio systems; must order UPLC AAA Application and Familiarization Services (741000299) when ordering this kit (not intended for IVD use)

205000614 Aflatoxin Analysis kit Includes everything required to perform aflatoxin analysis; includes large volume FLR flow cell

205000589 ACQUITY UPLC System solvent bottles and caps

Mobile phase bottles and caps; quantity of 7; includes amber and clear mobile phase bottles of 500-mL and 1000-mL capacity

205000343 UPLC in-line filter kit 0.2-µm particulate filter with holder for use at column inlet

Be Assured. Choose Waters Global Services .

Waters Global Services focuses on optimizing Waters products with superior

service, support, upgrades, training, and Waters Quality Parts.®