11
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd 11/20 us 8.200.350.01 Technical features filter/regulator Technical data B84G - standard models with integrated flush mounted gauge Symbol Port size (NPT) Drain Pressure range psi (bar) Filter element (µm) Bowl Weight lbs (kg) Model *1) 3/8 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-3AK-AP3-RMG 1/2 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-4AK-AP3-RMG 3/4 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-6AK-AP3-RMG 3/8 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-3AK-AD3-RMG 1/2 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-4AK-AD3-RMG 3/4 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-6AK-AD3-RMG 3/8 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-3AK-QP3-RMG 1/2 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-4AK-QP3-RMG 3/4 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-6AK-QP3-RMG 3/8 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-3AK-QD3-RMG 1/2 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-4AK-QD3-RMG 3/4 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-6AK-QD3-RMG *1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 145 psi (10 bar) Metal bowl: 290 psi (20 bar) Outlet pressure ranges: 5 ... 145 psi (0.3 ...10 bar), 5 ... 58 psi (0.3 ... 4 bar), 10 ... 250 psi (0.7 ... 17 bar) Filter element: 5 μm & 40 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Gauge: Integrated as standard , Gauge port 1/8, or electronic pressure sensor Flow: 212 scfm (100 dm 3 /s) at port size: 1/2”, inlet pressure 145 psi (10 bar), 91 psi (6.3 bar) set pressure and a Δp: 14.5 psi (1 bar) droop from set. Filter element: 40 μm Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 5 psi (0.35 bar) Bowl pressure required to open drain: ≤ 2.9 psi (0.2 bar) Minimum air flow required to close drain: 2 scfm (1 dm 3 /s) Ambient/Media temperature: Polycarbonate bowl: +14 ... +140ºF (-10 ... +60ºC) Metal bowl: -4 ... +149ºF (-20 ... +65ºC) Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C). Atex: Filter/regulators B84 are in conformity with Atex 2014/34/EU II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db excluding all versions with electronic pressure sensor Materials: Body: Die cast aluminum Body covers: ABS Bonnet: Acetal/Aluminum Valve: PP Transparent Bowl : Polycarbonate with Polyproplyene Guard. Metal Bowl: Die cast Aluminum with PA liquid level indicator lens Filter element: sintered PP Bowl ‘o’- ring: Chloroprene Elastomers: NBR B84G - General purpose filter/regulator Excelon® Plus Modular System > Port size: 3/8” ... 3/4” (ISO G/PTF) > Excelon ® Plus design allows in-line installation or modular installation with other Excelon ® Plus products > 5 or 40 micron particle and high efficiency water removal (> 98%) > Double safety lock bowl > Air purity classes in accordance to ISO8573- 1:2010: 7:8:4 (40μm) 6:8:4 (5μm) > Push to lock adjusting knob with built in tamper resistant feature > Metal bowl with prismatic liquid level indicator lens > Light weight Polycarbonate bowl > Easy to read flush mounted gauge as standard, integrated electronic pressure sensor as option

B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd

11/20us 8.200.350.01

Technical features filter/regulator

Technical data B84G - standard models with integrated flush mounted gauge Symbol Port size (NPT) Drain Pressure range

psi (bar)Filter element (µm)

Bowl Weightlbs (kg)

Model *1)

3/8 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-3AK-AP3-RMG1/2 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-4AK-AP3-RMG3/4 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-6AK-AP3-RMG3/8 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-3AK-AD3-RMG1/2 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-4AK-AD3-RMG3/4 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-6AK-AD3-RMG3/8 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-3AK-QP3-RMG1/2 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-4AK-QP3-RMG3/4 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 1.61 (0.73) B84G-6AK-QP3-RMG3/8 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-3AK-QD3-RMG1/2 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-4AK-QD3-RMG3/4 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 1.94 (0.88) B84G-6AK-QD3-RMG

*1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren

Medium:Compressed air onlyMaximum supply pressure:Polycarbonate bowl: 145 psi (10 bar)Metal bowl: 290 psi (20 bar)Outlet pressure ranges:5 ... 145 psi (0.3 ...10 bar),5 ... 58 psi (0.3 ... 4 bar),10 ... 250 psi (0.7 ... 17 bar)Filter element:5 μm & 40 μmPort size:G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTFGauge:Integrated as standard ,Gauge port 1/8, or electronic pressure sensor

Flow:212 scfm (100 dm3/s) at port size: 1/2”, inlet pressure 145 psi (10 bar), 91 psi (6.3 bar) set pressure and a Δp: 14.5 psi (1 bar) droop from set. Filter element: 40 μm Diaphragm Type: RelievingDrain:Manual or automatic Automatic drain operating conditions (float operated):Bowl pressure required to close drain: > 5 psi (0.35 bar) Bowl pressure required to open drain: ≤ 2.9 psi (0.2 bar)Minimum air flow required to close drain: 2 scfm (1 dm3/s)

Ambient/Media temperature:Polycarbonate bowl: +14 ... +140ºF (-10 ... +60ºC)Metal bowl:-4 ... +149ºF (-20 ... +65ºC) Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C). Atex: Filter/regulators B84 are in conformity with Atex 2014/34/EU

II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db excluding all versions with electronic pressure sensor

Materials:Body: Die cast aluminumBody covers: ABSBonnet: Acetal/AluminumValve: PPTransparent Bowl : Polycarbonate with Polyproplyene Guard.Metal Bowl: Die cast Aluminum with PA liquid level indicator lens Filter element: sintered PPBowl ‘o’- ring: ChloropreneElastomers: NBR

B84G - General purpose filter/regulatorExcelon® Plus Modular System

> Port size: 3/8” ... 3/4” (ISO G/PTF)

> Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products

> 5 or 40 micron particle and high efficiency water removal (> 98%)

> Double safety lock bowl

> Air purity classes in accordance to ISO8573-1:2010: 7:8:4 (40μm) 6:8:4 (5μm)

> Push to lock adjusting knob with built in tamper resistant feature

> Metal bowl with prismatic liquid level indicator lens

> Light weight Polycarbonate bowl

> Easy to read flush mounted gauge as standard, integrated electronic pressure sensor as option

Page 2: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltdus 8.200.350.02

> Electronic monitoring of secondary pressure> 1.44” full color graphic display. Excellent Visual Management.> Parameter Adjustment via front screen Buttons or Accessed Via IO-Link> Configurable switching output> Adjustable settings: Setpoint, Tolerance, Hysteresis, Pressure Units, Temperature Units, Screen Orientation, Digital Output Type (NPN, PNP, Push-Pull), Digital Output State (Normally High, Normally Low)> Install as a standard electronic pressure sensor or a pressure transducer with IO-Link

Secondary pressure measurement range:0 … 145 psi (0 … 10 bar, 0 … 1.0 MPa)Repeatability:≤ 0.1% of full scale (FS) at stable temperatureAccuracy:≤ 1.5% of full scale (FS) of detected pressure (0 … +50°C, +32 … +122°F)

Units:Pressure: bar, psi, MPaTemperature: °C, °FVoltage: V

Display:1.44” full color TFT LCDText / background colorswhite/green: pressure in rangewhite/red: pressure out of rangewhite/amber: errorblack/white: setting modeDisplay fields:User configurable identifier, pressure value, pressure units, user configurable message, menu

IO-Link function:Pressure informationPressure out of range warningsTemperature diagnosticSupply voltage diagnosticOperating time diagnosticMin. cycle time:20 ms

Technical features integrated electronic pressure sensor Electrical parameters

Electrical connection:M8 x 1Power supply:18 … 30 V d.c. Current consumption:20 mAElectromagnetic compatibility:According to EN 61000-6-2;EN 61000-6-3

Switching output:Configurable NPN / PNP / Push-Pull / NO / NC / hi-ZLoad current:100mA with short circuit protection

B84G - Filter/regulator with integrated electronic pressure sensor

Technical data B84G - standard models with integrated electronic pressure sensorSymbol Port size

(NPT)Drain Pressure range

psi (bar)Filter element (µm)

Bowl Weightlbs (kg)

Model *)

3/8 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 2.05 (0.93) B84G-3AK-AP3-RME1/2 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 2.05 (0.93) B84G-4AK-AP3-RME3/4 Auto 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 2.05 (0.93) B84G-6AK-AP3-RME3/8 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 2.38 (1.08) B84G-3AK-AD3-RME1/2 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 2.38 (1.08) B84G-4AK-AD3-RME3/4 Auto 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 2.38 (1.08) B84G-6AK-AD3-RME3/8 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 2.05 (0.93) B84G-3AK-QP3-RME1/2 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 2.05 (0.93) B84G-4AK-QP3-RME3/4 Manual 5 ... 145 (0.3 ... 10) 40 Guarded polycarbonate 2.05 (0.93) B84G-6AK-QP3-RME3/8 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 2.38 (1.08) B84G-3AK-QD3-RME1/2 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 2.38 (1.08) B84G-4AK-QD3-RME3/4 Manual 5 ... 145 (0.3 ... 10) 40 Metal with level indicator 2.38 (1.08) B84G-6AK-QD3-RME

*) All models shown here are supplied with integrated pressure sensor applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact IMI Norgren

For product IODD file please use the online link http://s.norgren.com/digital-gauge-iodd for a copy of the Quick Start Guide or comprehensive Operators manual please use the following online link www.norgren.com/excelon-plus

Electrical connection M8 x 1 Pin-No. Signal Cable

IO-LINK

1

2

3

4

+

OUT 2

-

C/Q

1 L+ (24V) brown

2 Out 2 (switching) white

3 L- (0V) blue

4 C/Q ( IO-Link) black

Page 3: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

B84G-⭑⭑⭑-⭑⭑⭑-R⭑⭑

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd us 8.200.350.03

Option selector *1)Port size Substitute3/8” 31/2” 43/4” 6Thread form SubstitutePTF AISO G parallel GAdjustment SubstituteKnob KT-bar T*2) Drain SubstituteManual QAuto drain ABowl SubstituteMetal with liquid indicator DTransparent with guard P

*1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren.

*2) Units with 17 bar outlet pressure range are available only with the T-bar adjustment and only with metal bowl. Not available in connection with integrated pressure sensor.

Gauge SubstituteWith integrated electronic pressure sensor *3)

E

With integrated gauge GWithout integrated gauge but with gauge port 1/8”

N

Pressure range *4) Substitute0,3 ... 4 bar F0,3 ... 10 bar M0,7 ... 17 bar S*2)Element Substitute40 µm 35 µm 1

*3) Only available with 10 or 4 bar pressure range

*4) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.

Page 4: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

0 20 40 60 80 100 120 140 dm3/s

Air �ow

0 40 80 120 160 200 240 280 scfm

Out

let p

ress

ure

0.8

0.6

0.4

0.2

0

bar

g

10

8

6

4

2

0

psig

Flow characteristicsPORT SIZE: 1/2"INLET PRESSURE: 145 psi (10 bar)

0 20 40 60 80 100 120 140 dm3/s

Air �ow

0 40 80 120 160 200 240 280 scfm

Out

let p

ress

ure

0.8

0.6

0.4

0.2

0

bar

g

10

8

6

4

2

0

psig

Flow characteristicsPORT SIZE: 1/2"INLET PRESSURE: 145 psi (10 bar)

0 20 40 60 80 100 120 140 dm3/s

Air �ow

0 40 80 120 160 200 240 280 scfm

Out

let p

ress

ure

0.8

0.6

0.4

0.2

0

bar

g

10

8

6

4

2

0

psig

Flow characteristicsPORT SIZE: 1/2"INLET PRESSURE: 145 psi (10 bar)

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltdus 8.200.350.04

Flow characteristicsInlet pressure: 145 psi (10 bar) Port size: 1/2”, 40 µm element

Inlet pressure: 145 psi (10 bar) Port size: 3/8”, 40 µm element

Inlet pressure: 145 psi (10 bar) Port size: 3/8”, 5 µm element

Page 5: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd us 8.200.350.05

Accessories Quikclamp®

Page 6

840014-51KIT

Quikclamp® with bracket assembled

Page 6

840014-52KIT

Neck mounting bracket and panel nut

Page 6

840068-51KIT

Panel mounting nut

Page 6

840048-89KIT

Mounting bracket

Page 6

840024-50KIT

Integrated gauge 10 bar gauge

840073-01KIT

Integrated gauge 20 bar gauge

840073-02KIT Gauge adaptor kit 1/8 PTF

840100-01KIT

Gauge adaptor kit R 1/8

840100-02KIT Pressure sensing block 1/4 PTF

Page 7

840016-50KIT

Pressure sensing block G1/4

Page 7

840016-51KIT Padlock

840055-01KIT

Lockout device

840055-02KIT

Full flow porting block vertical, 3/4”PTF

Page 7

840028-68KIT

Full flow porting block vertical, G3/4”

Page 7

840028-69KIT

Pressure switch interface block (18D pressure switch) G1/2

Page 8

0337717000000000

Full flow porting block horizontal, 3/4 PTF

Page 7

840028-50KIT

Full flow porting block horizontal, G3/4

Page 7

840028-53KIT

Port Adaptors

Page 8

3/8 PTF 840015-02KIT1/2 PTF 840015-03KIT3/4 PTF 840015-04KITG3/8 840015-10KITG1/2 840015-11KITG3/4 840015-12KIT

Hybrid Quikclamp® *1

Page 6

840014-61

Hybrid Quikclamp® with bracket assembled *1

Page 6

840014-62

*1) To connect new Excelon Plus to old Excelon 74/73 units. Having the same hole centers as 74 series mounting bracket. A Quikclamp adds 13.6 mm to the overall width of a combination unit

Page 6: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltdus 8.200.350.06

Electronic Pressure Sensor – stand alone version *3

Q84G

IO-Link cablesConnection cable M8x1 for integrated digital pressure sensor

Description Cable length (m) Model

M8 female to M12 male

0.6 NC-084FS-124MS-A1.0 NC-084FS-124MS-12.0 NC-084FS-124MS-25.0 NC-084FS-124MS-5

M8 female to free end 5.0 NC-084FS-00000-5

Pressure switch 18D (7.25 ... 116 psi) *1

Page 8

0881300000000000

Digital pressure switch 51D (-14.5 ... 145 psi) *2

Page 8

0860811000000000

Gauges (For regulators with gauge port instead of integrated port )

Center back connection, white face (for full technical specification see datasheet 8.900.900)

Pressure range(bar)*3) (MPa)

(psi) ø Thread size

Model

0 ... 6 0 ... 0.6 0 ... 84 40mm R1/8 18-015-8850 ... 10 0 ... 1 0 ... 145 40mm R1/8 18-015-9890 ... 25 0 ... 2.5 0 ... 362 40mm R1/8 18-015-908

*3) primary scale

Maintenance/Service Filter cartridge5 micron

840038-50KIT

Filter cartridge40 micron

840038-51KIT

Auto drain kit with metal Nut - Imperial

6000-61KIT

Auto drain kit with metal Nut - Metric

6000-60KIT

Spare parts Filter Bowl (Guarded Poly bowl with auto drain 6 mm PIF)

840025-51KIT

Filter Bowl (Guarded Poly bowl with manual drain)

840025-50KIT

Filter Bowl (Metal with S/Glass & auto drain, 6 mm PIF)

840003-51KIT

Filter Bowl (Metal with S/Glass & manual drain)

840003-50KIT Filter Bowl (Guarded Poly bowl with auto drain, 1/4 PIF)

840025-53KIT

Filter Bowl (Metal with S/Glass & auto drain, 1/4 PIF)

840003-56KIT

R84 / B84Elastomer Kit

FRLB84-KIT

*1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385 *3) Q84G standalone electronic pressure sensor module see http://s.norgren.com/digital-gauge-iodd for data-sheet 8.900.905.

Center back connection, black face

Pressure range(MPa) ø

Thread size Model(psi)*3) (bar)

0 ... 60 0 ... 4 0 ... 0.4 2" 1/8" NPT 18-015-2020 ... 160 0 ... 11 0 ... 1.1 2" 1/8" NPT 18-015-2040 ... 300 0 ... 20 0 ... 2.1 2" 1/8" NPT 18-015-205

*3) primary scale

Page 7: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

1 1

0.63

(16) 4.

65 (1

18)

4.84

(123

)

1.54

(39)

1.69

(43)

2

7.09

(143

)1.6

9 (4

3)

7.01 (

178)

7.99

(203

)

7.01 (

178)

# 25

4.84

(123

)

4.65

(118

)

0.63

(16)

1.54

(39)

1.69

(43)

7.09

(180

)#

25

2.91

(74)

1.50

(38)

2.28 (58)

2.76 (70)

2.91

(74)

1.5 0

(38)

2.28 (58)

2.76 (70)

2.91

(74)

1.50

(38)

2.28 (58)

2.76 (70)

44

Ø 35

1.73 (44)

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd us 8.200.350.07

Dimensions Dimensions in inches (mm) Projection/Third angle

# Minimum clearance for bowl removal1 Main ports 3/8”, 1/2” or 3/4”

(ISO G/PTF)2 Gauge port Rc 1/8 for ISO G and

1/8 PTF for PTF main ports

Automatic Drain1/4 Turn Manual Drain 1/4 Turn Manual Drain

With knob With T-bar

Page 8: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

11/20

7.01

(178

)

1.69

(43)

1.54

(39)

0.63

(16)

4.84

(123

)

1.54

(39)

# 25

1 6

1.97

(50)

1.65

(42)

1.42

(36)

7 0

5 8

0.63(16)

1.10(58)2.76(70)

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltdus 8.200.350.08

Dimensions in inches (mm) Projection/Third angle

Dimensions B84G- General Purpose Filter Regulator

1/4 Turn Manual Drain

With knob

Page 9: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

2.99 (76)

4.69

(119

)

2.13

(54)

0.28 (7)2.01 (51)

2.14

(54.

3)

1.85

(47)

1.93

(49)

0.55(14)

0.16 (4)

0.20(5)

2.20

(56)

0.45(11.5)

2.36 (60)

2.36

(60)

0.31 (8)

1.97

(50.

1)

2.77 (70.3)0.98 (25)

Ø2.14 (54.3)

6.1

0.91

(23)

0.28

(7.2

)

1.1

8 (3

0)

1.42 (36)0.24 (6.1)

1.81 (46)

2.01

(51)

0.96 (24.5)

4

2.01 (51)

0.26 (6.5)

2.91 (74)

90°

ø 0.

26 (6

.5)

2.01

(51)

4.02

(102

)

3.27

(83)

0.94 (24)

4

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd us 8.200.350.09

Dimensions in inches (mm) Projection/Third angle

Accessories

Quikclamp® with wall bracket Quikclamp®

Neck mounting bracketPanel mounting nut

Hybrid-Quikclamp® with wall bracket Hybrid-Quikclamp®

Recommended panel hole size: ø 55 mm ... 57 mm

Panel thickness: 2 ... 6 mm

Page 10: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

0.47

(12)

1.20

(30.

5)

2.80 (71)

1.22 (31) 0.59 (15)

2.64 (67)

1.07

(27.2

2.18

(55.

25)

1.44

(36.

5)0.

22 (5

.5)

0.20

(5 )

2.95 (75)

0.59(15) 2.32 (59) 0.

12 (3

)

0.59(15)

2.01

(5)

0.83(21)

1.30 (33)

1.77 (45)

1.52 (38.5)

1.52

(38.

5)

0.71 (18)

3.15 (80) 2.01 (51)

2.24

(57)

1.81 (

46)

2.68 (68)

1.73 (44)

1.26 (32)

1.57

(40)

1.57 (40)G1/2

3.15

(80)

2.68

(68)

2.01 (51)

2.24 (57)

1.81 (46)

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltdus 8.200.350.010

Mounting bracket

Pressure sensing block Pipe adaptor

Full flow porting block horizontal Full flow porting block vertical

Porting block for 18D pressure switch

Dimensions in inches (mm) Projection/Third angle

Page 11: B84G - General purpose filter/regulator Excelon® Plus Modular …cdn.norgren.com/pdf/B84G_Datasheet_US.pdf · 2021. 1. 18. · With flow direction right to left please use the online

~11.8

1 (30

0)1.2

2 (3

1)

1

3

56

4

7

1.22 (31)

G1/

8

1.44 (36.5)

~1.18

(~30

)

2

1.18 (30)

1.18

(30)

1.10 (28)

0.20

(5)

1.77

(45)18

A/C

1.38 (35)

2.83 (72)

1.14

(29)

1.14 (29)

G 1/8

37

11.8

1 (30

0)˷

1.22

(31)

31

1

2

3

4

6 57

1.22

(31)

1.26 (32)

1.73 (44)1.5

7 (4

0)

2.24 (57)

1.57 (40)

G 1/2

0.63 (16)

1.22 (31) 1.46 (37)

11/20Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. (2017 - 9217c) © 2020 Norgren Ltd us 8.200.350.011

Warning

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

EN - Englisch

51D Pressure switch - digital

1 Switch OUT 1, green LED 2 Switch OUT 2, red LED 3 Dustproof protector 4 Connector M12 x 1 5 Inlet port 6 Alternative inlet port G1/8 plugged 7 Thread for mounting screw

18D Pressure switch18D Porting block and 18D assembled Dimensions in inches (mm) Projection/Third angle