4
BL72 - EXCELON ® Modular System Filter/Regulator-Lubricator Combination Units 6/15 en 8.160.805.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8042b) © 2015 Norgren Inc. Medium: Compressed air only Maximum operating pressure: 10 bar (145 psi) Pressure range: 0,3 ...10 bar ( 4 ... 145 psi) Filter element: 40 μm standard Port size: G1/4, G3/8 Gauge port: Rc 1/8 Relieving: Standard Flow: BL72: 13 dm 3 /s maximum At port size: G1/4 Inlet pressure: 10 bar (145 psi) Outlet pressure: 6,3 bar (91 psi) Δp: 1 bar (14,5 psi) Filter element: 40 μm Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (2.9 psi) Minimum air flow required to close drain: 0,1 dm 3 /s (0.2 scfm) Manual operation: depress pin inside drain outlet to drain bowl Ambient/Media temperature: -20 ... +50°C (-4 ... +122°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: zinc Bowl: PC Elastomers: CR & NBR Operation pressure: Metal bowl: 17 bar (246 psi) Metal bowl with automatic drain: 10 bar (145 psi) Port size: 1/4 or 3/8 NPT Pressure range: 0,3 ... 4 bar (4 ... 58 psi) 0,3 ... 2 bar (4 ... 29 psi) 0,3 ... 17 bar (4 ... 247 psi) Filter element: 5 μm Gauge port: 1/8 PTF with PTF main ports Relieving: Without Drain: Semi-automatic Ambient/Media temperature: Metal bowl: -34 ... +65°C (-29 ... +149°F) Technical features - standard models Please contact IMI Norgren for following options: > Port size: G1/4 or G3/8 > Excelon design allows in-line installation or modular installation with other Excelon products > High efficiency water and particle removal > Quick release bayonet bowl > Push to lock adjusting knob with tamper resistant accessory > Flow sensor provides a nearly constant oil/air ratio over a wide range of flows > All round (360°) visibility of sightfeed dome for ease of drip rate setting Technical data BL72 (Filter/Regulator, Lubricator and Gauge) - standard models Symbol Air port Pressure range (bar) Element (µm) Drain Lubricator Mounting Shut-off valve Model G 1/4 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® with BL72-201GA G 3/8 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® with BL72-301GA G 1/4 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® with BL72-211GA G 3/8 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® with BL72-311GA G 1/4 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® without BL72-205GA G 3/8 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® without BL72-305GA G 1/4 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® without BL72-215GA G 3/8 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® without BL72-315GA G 1/4 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® with BL72-221G G 3/8 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® with BL72-321G G 1/4 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® with BL72-231G G 3/8 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® with BL72-331G G 1/4 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® without BL72-225G G 3/8 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® without BL72-325G G 1/4 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® without BL72-235G G 3/8 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® without BL72-335G

BL72 - EXCELON Modular System Filter/Regulator …cdn.norgren.com/pdf/en_8_160_805_BL72.pdf · BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units 6/15 en

Embed Size (px)

Citation preview

Page 1: BL72 - EXCELON Modular System Filter/Regulator …cdn.norgren.com/pdf/en_8_160_805_BL72.pdf · BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units 6/15 en

BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units

6/15en 8.160.805.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8042b) © 2015 Norgren Inc.

Medium:Compressed air onlyMaximum operating pressure:10 bar (145 psi)Pressure range:0,3 ...10 bar ( 4 ... 145 psi)Filter element:40 μm standardPort size:G1/4, G3/8Gauge port:Rc 1/8Relieving:Standard

Flow:BL72: 13 dm3/s maximum At port size: G1/4 Inlet pressure: 10 bar (145 psi) Outlet pressure: 6,3 bar (91 psi) Δp: 1 bar (14,5 psi) Filter element: 40 μmDrain:Manual or automaticAutomatic drain operatingconditions (float operated):Bowl pressure required toclose drain: > 0,35 bar (5 psi)Bowl pressure required toopen drain: ≤ 0,2 bar (2.9 psi)Minimum air flow required to

close drain: 0,1 dm3/s (0.2 scfm)Manual operation: depress pininside drain outlet to drain bowlAmbient/Media temperature:-20 ... +50°C (-4 ... +122°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials:Body: zincBowl: PCElastomers: CR & NBR

Operation pressure:Metal bowl: 17 bar (246 psi)Metal bowl with automatic drain: 10 bar (145 psi)Port size:1/4 or 3/8 NPT

Pressure range:0,3 ... 4 bar (4 ... 58 psi) 0,3 ... 2 bar (4 ... 29 psi) 0,3 ... 17 bar (4 ... 247 psi)Filter element:5 μm

Gauge port:1/8 PTF with PTF main portsRelieving:WithoutDrain:Semi-automatic

Ambient/Media temperature:Metal bowl:-34 ... +65°C (-29 ... +149°F)

Technical features - standard models

Please contact IMI Norgren for following options:

> Port size: G1/4 or G3/8

> Excelon design allows in-line installation or modular installation with other Excelon products

> High efficiency water and particle removal

> Quick release bayonet bowl

> Push to lock adjusting knob with tamper resistant accessory

> Flow sensor provides a nearly constant oil/air ratio over a wide range of flows

> All round (360°) visibility of sightfeed dome for ease of drip rate setting

Technical data BL72 (Filter/Regulator, Lubricator and Gauge) - standard modelsSymbol Air

portPressure range(bar)

Element (µm)

Drain Lubricator Mounting Shut-off valve

Model

G 1/4 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® with BL72-201GA

G 3/8 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® with BL72-301GA

G 1/4 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® with BL72-211GA

G 3/8 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® with BL72-311GA

G 1/4 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® without BL72-205GA

G 3/8 0,3 ... 10 40 Automatic Micro fog Quikclamp with wall bracket® without BL72-305GA

G 1/4 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® without BL72-215GA

G 3/8 0,3 ... 10 40 Automatic Oil fog Quikclamp with wall bracket® without BL72-315GA

G 1/4 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® with BL72-221G

G 3/8 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® with BL72-321G

G 1/4 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® with BL72-231G

G 3/8 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® with BL72-331G

G 1/4 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® without BL72-225G

G 3/8 0,3 ... 10 40 Manual Micro fog Quikclamp with wall bracket® without BL72-325G

G 1/4 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® without BL72-235G

G 3/8 0,3 ... 10 40 Manual Oil fog Quikclamp with wall bracket® without BL72-335G

Page 2: BL72 - EXCELON Modular System Filter/Regulator …cdn.norgren.com/pdf/en_8_160_805_BL72.pdf · BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units 6/15 en

BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8042b) © 2015 Norgren Inc.en 8.160.805.02

6/15

Gauge

Center back connection, white face (for full technical specification see datasheet 8.900.900)

Pressure range bar *1 Mpa psi Ø Thread size Model

0 ... 2,5 — 0 ... 36 40 mm R1/8 18-013-886

0 ... 4 0 ... 0,4 0 ... 58 40 mm R1/8 18-013-990

0 ... 10 0 ... 1 0 ... 145 40 mm R1/8 18-013-989

*1) primary scale

Accessories

Quikclamp®

Page 3

Quikclampwith wall bracket®

Page 3

Tamper resistant kit

4214-51 4214-52 4255-51

Quikmount pipe adaptor *1)

Page 3

Porting block with three alternative ports

Page 3

2/2 Shut-off valves (for full technical specification see datasheet 8.160.600)

Page 4

3/2 Shut-off valves (for full technical specification see datasheet 8.160.600)

Page 4

G1/4: 4215-08 G1/4: 4216-52 G1/4: T72B-2GA-P1N G1/4: T72T-2GA-P1N

G3/8: 4215-09 G3/8: T72B-3GA-P1N G3/8: T72T-3GA-P1N

*1) Please use a Quikmount pipe adaptor if the Quikclamp be mounted at inlet or outlet side.

Porting block for pressure switch

Pressure switch(0,5 ... 8 bar)

0523109000000000 0881300000000000

Padlock (brass) with two keys *1)

0613633000000000

*1) for shut-off valves and tamper resistant kit

Pressure switch Padlock

Page 3: BL72 - EXCELON Modular System Filter/Regulator …cdn.norgren.com/pdf/en_8_160_805_BL72.pdf · BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units 6/15 en

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8042b) © 2015 Norgren Inc.

BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units

en 8.160.805.036/15

Dimensions BL72 Dimensions in mm Projection/First angle

Manual drain

Semi automatic drain Automatic drain164,5

73

110,5

48,5

ø40

134

185

#

114

191

ø 35

~ 5

938

41

90°

Ņ 5

,3

A - B4,5

A

B

SW 3

176

ø 9,5

141

192

#

214

#

34

8

5

1

1

R1/8

# Minimum clearance required to remove bowl1 Main ports 1/4” or 3/8”3 Transparent bowl 4 Metal bowl with liquid indicator 5 Reduces by 4 mm with knob in locked position 8 Alternative gauge port Rc1/8 plugged

Accessories

Quikclamp® Porting blockQuikclamp® with wall bracket Pipe adapter

3

14

36,5

36,5

90°

74 59

14

38

4,5

56

ø 5

,3

3 36,5

36

36

3

28,5

2010

10 Ports (G1/4 or 1/4 NPT ) plugged

29

29

16A

1

1 Main ports 1/4” or 3/8” ISO G/PTF

Page 4: BL72 - EXCELON Modular System Filter/Regulator …cdn.norgren.com/pdf/en_8_160_805_BL72.pdf · BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units 6/15 en

BL72 - EXCELON® Modular System Filter/Regulator-Lubricator Combination Units

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8042b) © 2015 Norgren Inc.en 8.160.805.04

6/15

Dimensions in mm Projection/First angle

WarningThese products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.

Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden. Sie sind dort einzusetzen, wo die unter »Technische Merkmale/- Daten« aufgeführten Werte nicht überschritten werden. Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenser-haltenden- oder anderen Systemen, die nicht in den veröffentlichten Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an IMI NORGREN.Durch Missbrauch, Verschleiß oder Störungen können in Pneumatik-

systemen verwendete Komponenten auf verschiedene Arten versagen.Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berück-sichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um Verletzungen von Personen sowie Beschädigungen der Geräte im Falle einer solchen Störung zu verhindern. Systemausleger sind verpflichtet, Sicherheitshinweise für den End-benutzer im Betriebshandbuch zu vermerken, wenn der Störungs-schutz nicht ausreichend gewährleistet ist.

Neck mounting bracket

40

30

15

38

4,4

7

2,5

24,5

25

13 Pressure switch is not in scope of delivery 14 Alternative G1/4 ports plugged

1 Main ports

Shut-off valves

Porting block for pressure switch

Wall mounting bracket

46

18,5

8

35

38

60

8

39 51

7

42

1,51

40

30

15

38

4,4

7

2,5

24,5

25

48,5

50,5

42

67

25

16

1421

11

1

1

40

57

G1/4

40

3

40

31,5

+-

14

13

1 Main ports 1/4” or 3/8” ISO G/PTF 11 Exhaust port M5 at 3/2 valve only