Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
LB72G - EXCELON® Modular System General purpose filter regulator
02/16RW/en 8.160.300.01
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.
Medium:Compressed air onlyMaximum operating pressure:17 bar (246 psi)Pressure range:0,3 ...10 bar ( 4 ... 145 psi)Filter element:5 ... 40 μmPort size:G1/4, G3/8, 1/4 or 3/8 NPT
Gauge port:Rc 1/8 with ISO G main ports1/8 PTF with PTF main portsFlow:See table belowRelieving:StandardDrain:Manual
Ambient/Media temperature:-40 ... +65°C (-40 ... +150°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).
Materials:Body: zincBonnet: acetalValve: brass & NBRMetal bowl: zincLiquid level indicator lens (metalbowl): transparent PAFilter element: sintered PPElastomers: CR & NBR
Technical features
> Port size: 1/4” or 3/8” (ISO G/PTF)
> Excelon design allows in-line installation or modular installation with other Excelon products
> High efficiency water and particle removal
> Quick release bayonet bowl
> Push to lock adjusting knob with tamper resistant accessory
> Prismatic liquid level indicator lens
> Wide temperature range
> Shock and vibration tested to EN 61373, Category 1, class A and B
Technical data - standard modelsSymbol Port
sizeSize Flow*
dm3/s scfmPressure range(bar)
Filter element(µm)
Adjustment Weight (kg) (lbs)
Model
G1/4 Basic 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-2GK-ME3-RMN
1/4 PTF Basic 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-2AK-ME3-RMN
G3/8 — 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-3GK-ME3-RMN
3/8 PTF — 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-3AK-ME3-RMN
G1/4 Basic 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-2GK-ME1-RMN
1/4 PTF Basic 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-2AK-ME1-RMN
G3/8 — 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-3GK-ME1-RMN
3/8 PTF — 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-3AK-ME1-RMN
EN 61373
+65°C (+150°F)
-40°C (-40°F)
Option selector LB72G-˙˙˙-ME˙-RMNPort size Substitute
1/4” 2
3/8” 3
Thread form Substitute
PTF A
ISO G parallel G
Element Substitute
40 µm 3
5 µm 1
Adjustment Substitute
Knob (standard) K
T bar T
LB72G - EXCELON® Modular System General purpose filter regulator
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.RW/en 8.160.300.02
02/16
Inlet pressure: 10 bar (145 psi) Port size: 1/4”, 40 µm element
0 10 20 30 40
0 20 40 60 80
9
6
3
0
bar
150
120
90
60
30
0
psi
g
dm3/s
scfm
Out
let
pre
ssur
e
Air flow
Flow characteristics
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.
LB72G - EXCELON® Modular System General purpose filter regulator
RW/en 8.160.300.0302/16
Service kit Service kit Replacement elements
5 µm 40 µm
4381-513 4380-502 5925-03 5925-02
Service kit
Accessories
1
2
6
3
4
5
Quikclamp®
Page 4
Quikclamp with wall bracket® *1)
1Page 4
Neck mountingbracket
5Page 4
Panel nut(Aluminium)
4
Tamper resistant kit
3
Quikmount pipe adaptor *1)
Page 4
4214-58 4214-57 74316-51 4248-01 4255-51 G1/4: 4215-08
G3/8: 4215-09
1/4 PTF: 4215-02
3/8 PTF: 4215-03
*1) Please use a Quikmount pipe adaptor if the Quikclamp be mounted at inlet or outlet side.
GaugeCenter back connection, white face (for full technical specification see datasheet 8.900.900)
6Pressure range bar *1 Mpa psi Ø Thread size Model
0 ... 10 0 ... 1 0 ... 145 40 mm R1/8 18-013-989
*1) primary scale
Center back connection, black face for North America (for full technical specification see datasheet 8.900.900)
6
12 1 14
2 2
Pressure range psig *1 bar Mpa Ø Thread size Model
0 ... 160 0 ... 11 0 ... 1.1 1.5” (40 mm) 1/8 NPT 18-013-212
*1) primary scale
LB72G - EXCELON® Modular System General purpose filter regulator
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.RW/en 8.160.300.04
02/16
Dimensions in mm Projection/First angle
Drawings Standard
T bar
# Minimum clearance required to remove bowl 1 Main ports 1/4” or 3/8” 3 Transparent bowl 4 Metal bowl with liquid indicator 5 Reduces by 4 mm with knob in locked position 6 Panel hole ø 40 mm, Panel thickness 4 max. 7 Gauge port 1/8” 8 Alternative gauge port 1/8” plugged
48,5
42
50,5
127
176
#
73
2612
ø 35
6
4
7
8
5
1
1
63
48,5
102
AccessoriesQuikclamp® Quikclamp® with wall bracket Pipe adapter
3
14
36,5
36,5
90°
74 59
14
38
4,5
56
ø 5
,3
3 36,5
29
29
16A
1
1 Main ports 1/4” or 3/8” ISO G/PTF
Neck mounting bracket
40
30
15
38
4,4
7
2,5
24,5
25
WarningThese products are intended for use in industrial compressed air and rail transport systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Inc.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.
The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.