LB72G - EXCELON ® Modular System General purpose filter regulator 02/16 RW/en 8.160.300.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc. Medium: Compressed air only Maximum operating pressure: 17 bar (246 psi) Pressure range: 0,3 ...10 bar ( 4 ... 145 psi) Filter element: 5 ... 40 μm Port size: G1/4, G3/8, 1/4 or 3/8 NPT Gauge port: Rc 1/8 with ISO G main ports 1/8 PTF with PTF main ports Flow: See table below Relieving: Standard Drain: Manual Ambient/Media temperature: -40 ... +65°C (-40 ... +150°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: zinc Bonnet: acetal Valve: brass & NBR Metal bowl: zinc Liquid level indicator lens (metal bowl): transparent PA Filter element: sintered PP Elastomers: CR & NBR Technical features > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > High efficiency water and particle removal > Quick release bayonet bowl > Push to lock adjusting knob with tamper resistant accessory > Prismatic liquid level indicator lens > Wide temperature range > Shock and vibration tested to EN 61373, Category 1, class A and B Technical data - standard models Symbol Port size Size Flow* dm 3 /s scfm Pressure range (bar) Filter element (µm) Adjustment Weight (kg) (lbs) Model G1/4 Basic 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-2GK-ME3-RMN 1/4 PTF Basic 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-2AK-ME3-RMN G3/8 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-3GK-ME3-RMN 3/8 PTF 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-3AK-ME3-RMN G1/4 Basic 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-2GK-ME1-RMN 1/4 PTF Basic 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-2AK-ME1-RMN G3/8 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-3GK-ME1-RMN 3/8 PTF 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-3AK-ME1-RMN EN 61373 +65°C (+150°F) -40°C (-40°F) Option selector LB72G-˙˙˙-ME˙-RMN Port size Substitute 1/4” 2 3/8” 3 Thread form Substitute PTF A ISO G parallel G Element Substitute 40 µm 3 5 µm 1 Adjustment Substitute Knob (standard) K T bar T

LB72G - EXCELON Modular System General purpose filter …cdn.norgren.com/pdf/RW_en_8_160_300_LB72G.pdf · 2016. 3. 8. · RW/en 8.160.300.01 Our policy is one of continued research

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • LB72G - EXCELON® Modular System General purpose filter regulator

    02/16RW/en 8.160.300.01

    Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.

    Medium:Compressed air onlyMaximum operating pressure:17 bar (246 psi)Pressure range:0,3 ...10 bar ( 4 ... 145 psi)Filter element:5 ... 40 μmPort size:G1/4, G3/8, 1/4 or 3/8 NPT

    Gauge port:Rc 1/8 with ISO G main ports1/8 PTF with PTF main portsFlow:See table belowRelieving:StandardDrain:Manual

    Ambient/Media temperature:-40 ... +65°C (-40 ... +150°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

    Materials:Body: zincBonnet: acetalValve: brass & NBRMetal bowl: zincLiquid level indicator lens (metalbowl): transparent PAFilter element: sintered PPElastomers: CR & NBR

    Technical features

    > Port size: 1/4” or 3/8” (ISO G/PTF)

    > Excelon design allows in-line installation or modular installation with other Excelon products

    > High efficiency water and particle removal

    > Quick release bayonet bowl

    > Push to lock adjusting knob with tamper resistant accessory

    > Prismatic liquid level indicator lens

    > Wide temperature range

    > Shock and vibration tested to EN 61373, Category 1, class A and B

    Technical data - standard modelsSymbol Port

    sizeSize Flow*

    dm3/s scfmPressure range(bar)

    Filter element(µm)

    Adjustment Weight (kg) (lbs)

    Model

    G1/4 Basic 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-2GK-ME3-RMN

    1/4 PTF Basic 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-2AK-ME3-RMN

    G3/8 — 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-3GK-ME3-RMN

    3/8 PTF — 38 81 0,3 ... 10 40 Knob 0,36 0,79 LB72G-3AK-ME3-RMN

    G1/4 Basic 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-2GK-ME1-RMN

    1/4 PTF Basic 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-2AK-ME1-RMN

    G3/8 — 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-3GK-ME1-RMN

    3/8 PTF — 38 81 0,3 ... 10 5 Knob 0,36 0,79 LB72G-3AK-ME1-RMN

    EN 61373

    +65°C (+150°F)

    -40°C (-40°F)

    Option selector LB72G-˙˙˙-ME˙-RMNPort size Substitute

    1/4” 2

    3/8” 3

    Thread form Substitute

    PTF A

    ISO G parallel G

    Element Substitute

    40 µm 3

    5 µm 1

    Adjustment Substitute

    Knob (standard) K

    T bar T

  • LB72G - EXCELON® Modular System General purpose filter regulator

    Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.RW/en 8.160.300.02

    02/16

    Inlet pressure: 10 bar (145 psi) Port size: 1/4”, 40 µm element

    0 10 20 30 40

    0 20 40 60 80

    9

    6

    3

    0

    bar

    150

    120

    90

    60

    30

    0

    psi

    g

    dm3/s

    scfm

    Out

    let

    pre

    ssur

    e

    Air flow

    Flow characteristics

  • Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.

    LB72G - EXCELON® Modular System General purpose filter regulator

    RW/en 8.160.300.0302/16

    Service kit Service kit Replacement elements

    5 µm 40 µm

    4381-513 4380-502 5925-03 5925-02

    Service kit

    Accessories

    1

    2

    6

    3

    4

    5

    Quikclamp®

    Page 4

    Quikclamp with wall bracket® *1)

    1Page 4

    Neck mountingbracket

    5Page 4

    Panel nut(Aluminium)

    4

    Tamper resistant kit

    3

    Quikmount pipe adaptor *1)

    Page 4

    4214-58 4214-57 74316-51 4248-01 4255-51 G1/4: 4215-08

    G3/8: 4215-09

    1/4 PTF: 4215-02

    3/8 PTF: 4215-03

    *1) Please use a Quikmount pipe adaptor if the Quikclamp be mounted at inlet or outlet side.

    GaugeCenter back connection, white face (for full technical specification see datasheet 8.900.900)

    6Pressure range bar *1 Mpa psi Ø Thread size Model

    0 ... 10 0 ... 1 0 ... 145 40 mm R1/8 18-013-989

    *1) primary scale

    Center back connection, black face for North America (for full technical specification see datasheet 8.900.900)

    6

    12 1 14

    2 2

    Pressure range psig *1 bar Mpa Ø Thread size Model

    0 ... 160 0 ... 11 0 ... 1.1 1.5” (40 mm) 1/8 NPT 18-013-212

    *1) primary scale

  • LB72G - EXCELON® Modular System General purpose filter regulator

    Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2012 - B8033e) © 2015 Norgren Inc.RW/en 8.160.300.04

    02/16

    Dimensions in mm Projection/First angle

    Drawings Standard

    T bar

    # Minimum clearance required to remove bowl 1 Main ports 1/4” or 3/8” 3 Transparent bowl 4 Metal bowl with liquid indicator 5 Reduces by 4 mm with knob in locked position 6 Panel hole ø 40 mm, Panel thickness 4 max. 7 Gauge port 1/8” 8 Alternative gauge port 1/8” plugged

    48,5

    42

    50,5

    127

    176

    #

    73

    2612

    ø 35

    6

    4

    7

    8

    5

    1

    1

    63

    48,5

    102

    AccessoriesQuikclamp® Quikclamp® with wall bracket Pipe adapter

    3

    14

    36,5

    36,5

    90°

    74 59

    14

    38

    4,5

    56

    ø 5

    ,3

    3 36,5

    29

    29

    16A

    1

    1 Main ports 1/4” or 3/8” ISO G/PTF

    Neck mounting bracket

    40

    30

    15

    38

    4,4

    7

    2,5

    24,5

    25

    WarningThese products are intended for use in industrial compressed air and rail transport systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Inc.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

    The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.