15
DIR | www.dirsalonfurniture.uk | INSTRUCTION MANUAL Bella Ⅲ 7903

Bella Ⅲ - DIR Salon Furniture

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Bella Ⅲ - DIR Salon Furniture

DIR | www.dirsalonfurniture.uk |

INSTRUCTION MANUAL

Bella Ⅲ7903

Page 2: Bella Ⅲ - DIR Salon Furniture

x1

x1

x1

x4x4

x2x1

x1 x1

List of Parts & Tools

101001 7001 101003 0350/0388 101005

101006 101007 101008 101009 101010

101011 Water supply lines Adapter 5/8” 1/2”USA sizeType

1 1/4”

UK size

3.2cmDrain Hose Connector

Page 3: Bella Ⅲ - DIR Salon Furniture

101001

7001

Page 4: Bella Ⅲ - DIR Salon Furniture

Sink

Base

0350

0350

Page 5: Bella Ⅲ - DIR Salon Furniture
Page 6: Bella Ⅲ - DIR Salon Furniture

0350

Page 7: Bella Ⅲ - DIR Salon Furniture

Assembly Instruction 5

STEP 1 STEP 2

Faucet Set up

None Vacuum Breaker Sink Vacuum Breaker Sink

or0350 0388

Page 8: Bella Ⅲ - DIR Salon Furniture

STEP 1 STEP 2

STEP 4STEP 3

Unscrew the fastener from the sprayerhead holder.

Fasten the sprayerhead holder to the sink with the plastic fastener.

Unscrew the sprayerhead from the sprayer hose. Place the sprayer hose from underneath throught the sprayerhead holder and fasten the sprayerhead to the sprayer hose.

Assembly Instruction 6

0350

Sprayer Set UpNone Vacuum Breaker Sink

Page 9: Bella Ⅲ - DIR Salon Furniture

Sprayer Set UpVacuum Breaker Sink

Assembly Instruction 7

Unscrew the sprayerhead from the sprayer hose.

no need

0388

Page 10: Bella Ⅲ - DIR Salon Furniture

Plumbing Instruction 8

Sprayer Hose

Vacuum breaker hose

Shower Hose

None Vacuum BreakerSink

Vacuum BreakerSink

or

Page 11: Bella Ⅲ - DIR Salon Furniture

)

20 1/2” / 52cm

2 3 /

8” /

6cm

21 1 /

4” /

54c

m

Plumbing setup:*removable back panel to route both water supply lines and make all connections.

Page 12: Bella Ⅲ - DIR Salon Furniture

26 3/8” / 67cm

10 5

/8”

/ 27

cm

Floor plumbing setup:Circle opening on removable back for drain pipe exit

Page 13: Bella Ⅲ - DIR Salon Furniture

Please leave minimum 7 7/8”/ 20cm of space measuring from finished wall to the back of the sink to allow sinks tilting position.

Wall plumbing setup:All connection pipes are enclose within the base unit.Water supply lines are routed into the unit via circle opening on the back of the base.

52 3/8” / 130cm

38 1 /

2” /

98c

m

Page 14: Bella Ⅲ - DIR Salon Furniture

Secure the backwash on the floor by the provided floor anchors.

BACK FRONT

Topview

22 7 /

8” / 58cm

1 3 /

8” / 3.5cm

3/8” / 8mm

Page 15: Bella Ⅲ - DIR Salon Furniture

66 Rea Street SouthBirmingham B5 6LB UK -----------------------------Tel: +44(0)121 6434777-----------------------------Email:[email protected]

DIR BIRMINGHAM

[email protected]

Unit 1 River Road Business Park33 River Road, BarkingGreater London IG11 0DAUK-----------------------------Tel: +44(0)20 8591 9310--------- --------------------Email:

DIR LONDON

Unit 20, Goldenbridge Ind.Estate Tyrconnell RoadInchicoreDublin 8Republic of Ireland

------------------------------Phone: +353 (1) 429 7969------------------------------Email:[email protected]

DIR IRELAND

USA

Tel:

sale

DIR NEW YORK

575 Underhill Blvd.Suite 170Syosset, NY 11791

---------------------------

+1 (718)628-6668+1 (800)728-2008-------- ---------------------Email:

[email protected]

Warranty

Product care

Brush away excess hairClean surface with damp cloth or use simple soap & water solution.

Avoid using corrosive clean-ing agents such as bleaches.

Do not remove upholstery for cleaning

The warranty period is one year. DIR warrants to you, the original buyer, that goods shall be free of defects in material and/or workmanship attributable to manufacture for one year from date of s receipt of product. Damage resulting from improper handling after merchandise is received, or from exposure to weather or extreme atmospheric conditions is not covered by the warranty.For any other information please contact our support team: