2
On the 23rd December 2011 Hammersmith Flyover was infamously closed due to the detection of significant damage to the post tension cables, with significant media coverage. The story however started many years earlier. Built in the 1961, Hammersmith Flyover is a precast, post tensioned segment concrete box girder over 622m long with 17 spans carrying 4 lanes of traffic into London. After 2000, post tension special inspection had identified some deterioration and a strain gauge monitoring system was installed to identified to detect deterioration. After spurious results from the strain gauge monitoring, TfL revised their strategy, and looked to use innovative long term Acoustic Emission monitoring to confirm the location and extent of deterioration of the post tension cables by detecting wire break. An internal automated total station system was to measure sagging to detect the onset of failure. Additionally, extensive strain and movement monitoring of piers and bearings was requested to establish the performance of the flyovers bearings that unusually were located at the base of the pier. After an initial survey of the structure which defined the optimised sensor layout (and cost), Mistras were awarded in 2009 the structural monitoring of Hammersmith Flyover by Amey as part of TfL’s northern frame work contract (LOHAC). Over 8 weeks Mistras designed and installed the Acoustic Emission (AE) and structural health monitoring system, working in challenging confined space conditions. After successfully passing commissioning with mapping of signal transmission, TfL carried out a blind wire break, by cutting an exposed wire. This was successfully detected and located using our embedded wire break neural network fully validating the Mistras system. Over the next 18 months, nearly 400 wire breaks were detected and processed automatically by the monitoring system onsite, uploaded to a bespoke and secure customer website along with other structural health results. This information provided short term reassurance of safety, and clear evidence of an integrity issue, allowing ranked spans wire break severity. This triggered TfL’s preparation process for further investigations, contingency planning and advanced warning to senior management. Critical Structural Health Monitoring of Hammersmith Flyover INFRASTRUCTURE | CASE STUDY Hammersmith Flyover design BBC breaks the news, 23rd Dec 2011 AE and strain sensors installed One Source for Asset Protection Solutions CASE STUDY

Critical Structural Health Monitoring of Hammersmith Flyover · 2020-02-26 · Hammersmith Flyover design BBC breaks the news, 23rd Dec 2011 AE and strain sensors installed One Source

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Critical Structural Health Monitoring of Hammersmith Flyover · 2020-02-26 · Hammersmith Flyover design BBC breaks the news, 23rd Dec 2011 AE and strain sensors installed One Source

On the 23rd December 2011 Hammersmith Flyover was infamously closed due to the detection of significant damage to the post tension cables, with significant media coverage. The story however started many years earlier.

Built in the 1961, Hammersmith Flyover is a precast, post tensioned segment concrete box girder over 622m long with 17 spans carrying 4 lanes of traffic into London. After 2000, post tension special inspection had identified some deterioration and a strain gauge monitoring system was installed to identified to detect deterioration.

After spurious results from the strain gauge monitoring, TfL revised their strategy, and looked to use innovative long term Acoustic Emission monitoring to confirm the location and extent of deterioration of the post tension cables by detecting wire break. An internal automated total station system was to measure sagging to detect the onset of failure. Additionally, extensive strain and movement monitoring of piers and bearings was requested to establish the performance of the flyovers bearings that unusually were located at the base of the pier.

After an initial survey of the structure which defined the optimised sensor layout (and

cost), Mistras were awarded in 2009 the structural monitoring of Hammersmith Flyover by Amey as part of TfL’s northern frame work contract (LOHAC). Over 8 weeks Mistras designed and installed the Acoustic Emission (AE) and structural health monitoring system, working in challenging confined space conditions.

After successfully passing commissioning with mapping of signal transmission, TfL carried out a blind wire break, by cutting an exposed wire. This was successfully detected and located using our embedded wire break neural network fully validating the Mistras system.

Over the next 18 months, nearly 400 wire breaks were detected and processed automatically by the monitoring system onsite, uploaded to a bespoke and secure customer website along with other structural health results. This information provided short term reassurance of safety, and clear evidence of an integrity issue, allowing ranked spans wire break severity.

This triggered TfL’s preparation process for further investigations, contingency planning and advanced warning to senior management.

Critical Structural Health Monitoring of Hammersmith Flyover

INFRASTRUCTURE | CASE STUDY

Hammersmith Flyover design

BBC breaks the news, 23rd Dec 2011

AE and strain sensors installed

One Source forAsset Protection Solutions CASE STUDY

Page 2: Critical Structural Health Monitoring of Hammersmith Flyover · 2020-02-26 · Hammersmith Flyover design BBC breaks the news, 23rd Dec 2011 AE and strain sensors installed One Source

Monitoring Services Provided

Acoustic emission for post tension wire break

Strain in concrete

Bearing movement monitoring

High resolution crack monitoring

Automated total station movement monitoring

Expansion joint movement monitoring

Flood detection and height monitoring

Customers Benefits

Complete design and installation of all SHMS elements

Real time monitoring intelligent results

High value and accuracy results, critical to decision making

Ability to evolve monitoring throughout the project

Confined space management

MISTRAS Group Norman Way Industrial Estate, Over, Cambridge CB24 5QE

T: 01954 231612 E: [email protected]

www.mistrasgroup.co.uk

These initial wire break results lead the Amey investigation team to specific locations (+/-100mm from each tendons datum). This targeted destructive investigation at key hot spots revealed increasingly concerning results, including fully severed tendons, prompting the closure of the Flyover on 23rd December 2011.

During the Phase 1 strengthening of the most damaged spans in early 2012 by Amey, the initial AE monitoring system was extended to the 6.5 west side spans. This and strengthening were successfully completed before the start of the London Olympics allowing the reopening of the structure.

Monitoring of the unstrengthened spans continued until and throughout Phase 2 strengthening in 2015 providing continuous feedback about deterioration rate. This deterioration rate coupled with accurate PTSI information allowed the date prediction of each individual span failure, enabling prioritisation of span repair.

During Phase 2 Strengthening by Costain, Mistras adapted the structural health monitoring system to provide addition crack monitoring and segment separation gauges added along the viaduct. Data was provided in near real time to the Costain team as part of their temporary works.

Once the HFO strengthening was completed in 2016, the AE monitoring was decommissioned leaving behind a new long term structural health monitoring system to measure the new bearing performance, flooding detection and segment separation at key locations.

Services in this turnkey project included;

Confined space management and rescue for the works

Design, supply and integration of <800 wire break and AE sensor monitoring system

Installation and commissioning of all sensors

Software programming and data processing

Long term monitoring support, data analysis and reporting

In addition to the above Mistras provided non-destructive testing of welds, vibration monitoring, rebar detection and sizing with ferroscan, concrete coring, confined space rescue and management

Since this project, Mistras has used this post tension wire and strand monitoring technology on many structures for Highways England and councils in the UK plus post tension structures across Europe, Scandinavia and the USA.

One Source forAsset Protection Solutions CASE STUDY

Wire break and structural health systems onsite Broken wire and detected signals from the TfL blind trial

AE wire break with visually confirmed breakshelped determine remaining capacity