5
EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY VOL. 14/2-2013 135 R.E. Tirali, S.B. Çehreli, R. Yazıcı*, Z. Yalçınkaya Baskent University Faculty of Dentistry, Department of Pediatric Dentistry, Ankara, Turkey *Hacettepe University Faculty of Dentistry, Department of Conservative Dentistry, Ankara, Turkey e-mail: [email protected] Keywords Compomer; Composite; Glass ionomer; Surface roughness. ABSTRACT Aim The aim of this study was to investigate the effect of two antierosive pastes, Pronamel and Tooth Mousse Plus, on surface roughness of two composite (Filtek Supreme Ultra Universal Restorative and TPH Spectrum Restorative), one compomer (Dyract Extra), and two conventional glass ionomer restorative materials (Ionofil U and SDI) Materials and methods Study design 14 discs (10 mm diameter x 2 mm thickness) were prepared for each material (n =14 x 5). The discs were randomly divided into two groups to receive either GC Tooth Mousse Plus application or Sensodyne Pronamel application with toothbrush. The surface roughness of the brushed samples were recorded by laser profilometer. Statistics Wilcoxon, Kruskal Wallis test and multiple comparison tests were used to analyse the data. Results It was revealed that the surface roughness of the Filtek Supreme, TPH, Dyract and Riva Selfcure materials were not affected from application of either pastes (p>0.005). However, surface roughness of manually mixed glass ionomer (Ionofıl U) was significantly increased when brushed with both Tooth Mousse and Pronamel paste (p<0.001). Conclusion Neither Pronamel, nor Tooth Mousse caused a significant change on the surface roughness of tested restorative materials except Ionofil U. It was significantly increased following brushing with either paste. Effect of two anti-erosion pastes on surface roughness of different restorative materials Introduction Irregular surface characteristics of dental restorative materials might induce pellicle formation and the ability of bacteria to colonise in the oral cavity [Bollen, 1997; Marsh and Nyvad, 2003]. It has been shown that mean roughness > 0.2µm was related with a substantial increase in bacterial retention [Quirynen et al., 1996]. Plaque retention not only causes gingival and periodontal inflammation, but it also results in solubility of the organic matrix of restorative materials due to formation of acids by the biofilm. Thus, both the aesthetic and, physical properties, as well as and longevity of the restorations are impaired by an increase in plaque accumulation. For this reason, clinicians tend to create a smooth and polished restoration surface with various finishing and polishig techniques. A variety of factors, including prophylaxis procedures and toothbrushing with tooth paste, may alter the quality of the surface of both the enamel and the polished restorative materials in the oral cavity [Ehmford, 1983; Garcia-Godoy et al., 2009]. Studies that evaluated the effect of toothbrushing on the deterioration of composite resin materials demonstrated a rapid increase in surface roughness and found differences among the various restorative materials [Neme etal., 2002; Tanoue et al., 2000]. Dental erosion is defined as an irreversible loss of dental hard tissues due to a chemical process without the involvement of microorganisms [Bartlett, 2005]. The process may be associated with an intrinsic factor, i.e. gastric acid; or it may be caused by extrinsic factors related to dietary habits and lifestyle. To date, clinical management of dental erosion has relied on restricting contact with erosive foodstuffs together with the application of topical fluoride agents [Bartlett, 2005]. Recently, two new toothpaste-based products have been introduced in the market that claim to prevent erosion [Rees et al., 2007]. These are Sensodyne Pronamel (GSK Consumer Healthcare, St. George’s Avenue, Weybridge, Surrey) and Tooth Mousse (GC Dental, 22/23 Coopers Court, Newport Pagnell, Buckinghamshire). Tooth mousse is a water based milk protein derivative containing casein phosphopeptide with amorphous calcium phosphate and Pronamel is a derivative of Sensodyne tooth paste with high levels of bioavailable fluoride which also contain potassium nitrate (5% w/w). A recent in vitro research [Rees et al., 2007] suggested that both Pronamel and Toothmousse were effective in preventing erosion of permanent tooth. Although both pastes are being tested regarding their effects on enamel remineralisation and erosion, no data is available on their effects on surface roughness of restorative materials. The objective of this in vitro mettere study was to test the effects of Pronamel and Tooth Mousse Plus pastes on the surface roughness of commonly used dental materials in paediatric dentistry. Tested materials were two hybrid art_207 12 Burcak.indd 135 07/05/13 11:42

Effect of two anti-erosion pastes on surface roughness ...admin.ejpd.eu/download/EJPD_2013_02_10.pdf · tooth pastes on the baseline and final surface roughness of the restorative

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Effect of two anti-erosion pastes on surface roughness ...admin.ejpd.eu/download/EJPD_2013_02_10.pdf · tooth pastes on the baseline and final surface roughness of the restorative

EuropEan Journal of paEdiatric dEntistry vol. 14/2-2013 135

R.E. Tirali, S.B. Çehreli, R. Yazıcı*, Z. Yalçınkaya

Baskent University Faculty of Dentistry, Department of Pediatric

Dentistry, Ankara, Turkey

*Hacettepe University Faculty of Dentistry, Department of

Conservative Dentistry, Ankara, Turkey

e-mail: [email protected]

Keywords Compomer; Composite; Glass ionomer; Surface roughness.

abstract

Aim The aim of this study was to investigate the effect of two antierosive pastes, Pronamel and Tooth Mousse Plus, on surface roughness of two composite (Filtek Supreme Ultra Universal Restorative and TPH Spectrum Restorative), one compomer (Dyract Extra), and two conventional glass ionomer restorative materials (Ionofil U and SDI) Materials and methods Study design 14 discs (10 mm diameter x 2 mm thickness) were prepared for each material (n =14 x 5). The discs were randomly divided into two groups to receive either GC Tooth Mousse Plus application or Sensodyne Pronamel application with toothbrush. The surface roughness of the brushed samples were recorded by laser profilometer.Statistics Wilcoxon, Kruskal Wallis test and multiple comparison tests were used to analyse the data.Results It was revealed that the surface roughness of the Filtek Supreme, TPH, Dyract and Riva Selfcure materials were not affected from application of either pastes (p>0.005). However, surface roughness of manually mixed glass ionomer (Ionofıl U) was significantly increased when brushed with both Tooth Mousse and Pronamel paste (p<0.001).Conclusion Neither Pronamel, nor Tooth Mousse caused a significant change on the surface roughness of tested restorative materials except Ionofil U. It was significantly increased following brushing with either paste.

Effect of twoanti-erosion pasteson surface roughnessof different restorative materials

Introduction

Irregular surface characteristics of dental restorative materials might induce pellicle formation and the ability of bacteria to colonise in the oral cavity [Bollen, 1997; Marsh and Nyvad, 2003]. It has been shown that mean roughness > 0.2µm was related with a substantial increase in bacterial retention [Quirynen et al., 1996]. Plaque retention not only causes gingival and periodontal inflammation, but it also results in solubility of the organic matrix of restorative materials due to formation of acids by the biofilm. Thus, both the aesthetic and, physical properties, as well as and longevity of the restorations are impaired by an increase in plaque accumulation. For this reason, clinicians tend to create a smooth and polished restoration surface with various finishing and polishig techniques.

A variety of factors, including prophylaxis procedures and toothbrushing with tooth paste, may alter the quality of the surface of both the enamel and the polished restorative materials in the oral cavity [Ehmford, 1983; Garcia-Godoy et al., 2009]. Studies that evaluated the effect of toothbrushing on the deterioration of composite resin materials demonstrated a rapid increase in surface roughness and found differences among the various restorative materials [Neme etal., 2002; Tanoue et al., 2000].

Dental erosion is defined as an irreversible loss of dental hard tissues due to a chemical process without the involvement of microorganisms [Bartlett, 2005]. The process may be associated with an intrinsic factor, i.e. gastric acid; or it may be caused by extrinsic factors related to dietary habits and lifestyle. To date, clinical management of dental erosion has relied on restricting contact with erosive foodstuffs together with the application of topical fluoride agents [Bartlett, 2005]. Recently, two new toothpaste-based products have been introduced in the market that claim to prevent erosion [Rees et al., 2007]. These are Sensodyne Pronamel (GSK Consumer Healthcare, St. George’s Avenue, Weybridge, Surrey) and Tooth Mousse (GC Dental, 22/23 Coopers Court, Newport Pagnell, Buckinghamshire). Tooth mousse is a water based milk protein derivative containing casein phosphopeptide with amorphous calcium phosphate and Pronamel is a derivative of Sensodyne tooth paste with high levels of bioavailable fluoride which also contain potassium nitrate (5% w/w). A recent in vitro research [Rees et al., 2007] suggested that both Pronamel and Toothmousse were effective in preventing erosion of permanent tooth. Although both pastes are being tested regarding their effects on enamel remineralisation and erosion, no data is available on their effects on surface roughness of restorative materials.

The objective of this in vitro mettere study was to test the effects of Pronamel and Tooth Mousse Plus pastes on the surface roughness of commonly used dental materials in paediatric dentistry. Tested materials were two hybrid

art_207 12 Burcak.indd 135 07/05/13 11:42

Page 2: Effect of two anti-erosion pastes on surface roughness ...admin.ejpd.eu/download/EJPD_2013_02_10.pdf · tooth pastes on the baseline and final surface roughness of the restorative

TIRALI R.E. ET AL.

EuropEan Journal of paEdiatric dEntistry vol. 14/2-2013136

composite resins, one polyacid-modified composite resin and one conventional glass ionomer cement. Two null hypothesis were formulated: the surface roughness of all tested materials would be effected following application of either of the pastes; toohpaste and material type would affect the results.

Materials and methods

Two microhybrid resin composites (Filtek Supreme Ultra Universal Restorative, 3M ESPE, St. Paul, Minnesota, and TPH Spectrum Restorative, Dentsply, Germany), one compomer (Dyract Extra, Dentsply, Germany), and two conventional glass ionomer cements (Ionofil U, VOCO, Cuxhaven, Germany) (Riva Self Cure, SDI Limited, Australia) were tested in this study. Fourteen discs (10 mm diameter x 2 mm thickness) were prepared for each material (n= 14 x 5) by the help of a prefabricated plexiglass mold. Ionofil U was prepared by mixing the powder and liquid for 30 s at room temperature (23 °C, 50% relative humidity) in accordance with the manufacturer’s directions. The other glass ionomer cement, Riva Self Cure (SDI Limited, Australia) was mixed with an amalgamator (Ultramat S, SDI Limited, Australia) for 10 s as in the manufacturer’s instructions. Both glass inomers have a setting time of approximately 6 minutes (4.30 minutes for Riva and 5 minutes for Ionofil U respectively). Thus, following initial setting, all materials were placed in the discs. Mylar strips were placed over the top and bottom surfaces of the uncured resin composites and compomer and photopolymerisation was performed with a Quartz-Tungsten Halogen Dental Curing Light (Hilux Optimax, Benlioglu, Istanbul, Turkey) for 40 s on each side. The light output of the curing light unit (500 mW/cm2) was monitored with a hand-held dental radiometer (Model 100 Curing Radiometer, Demetron Research Corp., Danbury, CT, USA). Following setting and photopolymerisation, all specimens were taken out from the mold, immersed in tap water and stored in 37 °C for 24 h. Then, both the top and bottom sides of all discs were polished by the same operator with 400, 600 and 1000 grid abrasive discs respectively. After each polishing step, specimens were ultrasonically cleaned and immersed in deionized water in order to remove the residues. For each type of material, the discs were randomly divided into two groups and received either GC Tooth Mousse Plus (Recaldent, Victoria, Australia) application or Sensodyne Pronamel (GlaxoSmithKline, Australia) application with tooth brush. To simulate home application procedures, 2 ml of paste was applied the surfaces of tested materials for 2 min. During the 2 min, 120 brush strokes/min were applied manually by the same operator (ZY). The pastes were immersed in a plastic container and labelled as paste A and Paste B, the discs were numbered per group by a laboratory technician prior to brushing procedure. Following application of the paste, the specimen was

rinsed under tap water and placed in distilled water until the next application. The application and washing procedures were repeated 2 times a day for one week.

The surface roughness of the samples was recorded by a laser profilometer (MicroXAM Interferometric Surface Profiler, Dublin, Ireland). The average surface roughness (Ra, µm) was measured using MapVue AE software, Version 1.20. from 3 tracings at 3 different locations on each specimen at baseline and following brushing procedure. For qualitative examination under scanning electron microscopy (SEM) (JEOL JSM 5200, Tokyo, Japan), 4 additional samples were prepared for each material, 2 for baseline evaluation and 2 for evaluation of the brushed surfaces. Specimens were sputter coated with gold and evaluated with accelerated voltage (20 kV) under SEM.

Statistical analysisStatistical analysis was performed with the Statistical

Package for Social Sciences (SPSS) 11.5 software (SPSS Inc., Chicago, IL, United States). Shapiro Wilk test was used to verify normal distribution of data. Homogeneity of variances was evaluated by the Levene test. Data were expressed as median (IQR). Wilxocon test with Bonferroni correction was used to determine the possible difference among groups before and after brushing with tooth pastes and p<0.005 was set as significance. Mann Whitney U test was used to analyse the effect of tooth pastes on the baseline and final surface roughness of the restorative materials. According to Bonferroni correction, p<0.001 was set as significant (Table 1). Within tooth paste groups, the difference between baseline and final surface roughness of different

TABLE 1 Comparison of initial and final (after brushing with PN or TM) surface roughness values (Ra) of tested restoratives according to tooth paste applied.

GROUP BASELINE AFTER BRUSHING P-VALUEa

Ionofil UPn 1.77 (0.71) 2.15 (0.61) <0.001

Tm 2.33 (0.41) 2.91 (0.96) <0.001

TPHPn 0.50 (0.13) 0.47 (0.61) 0.277

Tm 0.43 (0.13) 0.41 (0.08) 0.538

DyractPn 0.23 (0.08) 0.21 (0.06) 0.252

Tm 0.23 (0.08) 0.25 (0.06) 0.202

FiltekPn 0.27 (0.10) 0.28 (0.10) 0.939

Tm 0.29 (0.07) 0.30 (0.08) 0.402

Riva Sefcure Pn 0.62 (0.43) 0.68 (0.31) 0.083

Tm 0.75 (0.39) 0.85 (0.26) 0.369a= Wilcoxon test with Bonferroni correction. Results are significant at p<0.005

art_207 12 Burcak.indd 136 07/05/13 11:42

Page 3: Effect of two anti-erosion pastes on surface roughness ...admin.ejpd.eu/download/EJPD_2013_02_10.pdf · tooth pastes on the baseline and final surface roughness of the restorative

ANTIEROSION PASTES AND SURFACE ROUGHNESS

EuropEan Journal of paEdiatric dEntistry vol. 14/2-2013 137

restorative materials was evaluated with Kruskal Wallis test at p<0.025 confidence.

Results

When the intact (control) surfaces of tested materials were compared, the highest Ra values were observed in Ionofil group followed by Riva Selfcure, TPH, Filtek and Dyract respectively.

After brushing with Pronamel (PN) there was no significant difference between Ra values of baseline and brushed surfaces for Filtek, TPH, Dyract Extra and Riva Selfcure (p=0.939; p=0.277; p=0.252 and p=0.083 respectively). Similarly, brushing with Tooth Mousse (TM) yielded no significant difference between

Ra values of the baseline and brushed surfaces for Filtek, TPH, Dyract Extra and Riva Selfcure (p=0.402; p=0.538; p=0.202 and p=0.369, respectively). Only Ionofil U displayed significantly rougher surface when brushed with either TM or PN (p<0.001). Briefly, application of either PN or TM did not have any significant effect on the surface roughness of the tested restorative materials except for Ionofil U(p>0.005 and p<0.001, respectively) (Table 1). Thus the first hypothesis was partially rejected, and the second null hypothesis was completely rejected.

Scanning electron microscopyQualitative evaluation of each material is given in

Figures 1, 2, 3, 4, 5. In general, Tooth Mousse left clusters on the majority of the restorative materials. It

FIG. 1 SEM picture of Riva Self Cure glass ionomer material under 200x magnification. TM: Tooth Mousse specimen, P: Pronamel specimen, C: Control.

FIG. 3 SEM picture of Dyract Extra compomer material under 200x magnification. TM: Tooth Mousse specimen, P: Pronamel specimen, C: Control. Note that Tooth Mousse displayed residues over the specimen.

FIG. 2 SEM picture of Ionofil U glass ionomer material under 200x magnification. TM: Tooth Mousse specimen, P: Pronamel specimen, C: Control. Note the cracks within the material.

FIG. 4 SEM picture of Z250 composite material under 200x magnification. TM: Tooth Mousse specimen, P: Pronamel specimen, C: Control.

art_207 12 Burcak.indd 137 07/05/13 11:42

Page 4: Effect of two anti-erosion pastes on surface roughness ...admin.ejpd.eu/download/EJPD_2013_02_10.pdf · tooth pastes on the baseline and final surface roughness of the restorative

TIRALI R.E. ET AL.

EuropEan Journal of paEdiatric dEntistry vol. 14/2-2013138

was observed that the voids and bubbles within the Ionofil became more prominent following brushing with either Tooth Mousse or Pronamel. Resin containing materials did not display significant changes. Overall, cracks were observed within glass ionomer materials both for intact and brushed samples (Fig. 1, 2). Although irregular scratches were observed on brushed materials, none of them was dramatically different from the intact samples.

Discussion and conclusion

Various factors such as aging, erosion, or prophy procedures affect the chemical and physical characteristic of restorative materials as well as their surface conditions [Catelon et al., 2010].

To date, a number of studies evaluated the effect of toothbrushing on the deterioration of composite resin materials for direct and indirect use showed a rapid increase in surface roughness and found differences between the materials [Goldstein and Turner, 1991; Kanter et al.; 1982, Aker, 1982]. However, the number of brush strokes, the load applied when brushing and the presence of toothpaste were not standard, thus the results of the studies are hardly comparable. Therefore, simulated toothbrush tests became more popular in time. On the other hand, according to a human study, the forces applied through the brushes to the surfaces of the teeth during tooth brushing vary to such a degree that the authors stated “any arbitrarily set hypothetical standards for such forces would be meaningless”. The results demonstrated that bristle structure and pattern of the toothbrush appear to be determining factors in brushing forces during toothbrushing and it is obviously possible to limit those forces by the selection of brushes with appropriate bristles [Fraleigh et al., 1967].

Another problem in dental literature is that, the number of toothbrushing cycles needed to simulate 1 year's tootbrushing remains unclear [Golstein and Turner, 1991]. Ranges from 4,320 to 16,000 have been suggested [Kanter et al., 1982, Aker, 1982]. In the present study, we did not use a toothbrushing machine, but we used a standard number of strokes for each specimen and we intended to mimic a one-week oral hygiene procedure of an individual. While people might brush their teeth for 2 min, twice per day, it is likely that each tooth surface is only experiencing the brushing for a fraction of this time. Videotaped recordings of 31 patients and their toothbrushing habits revealed a mean stroke length of 1 cm/stroke and a brushing rate of 15 cm/s for circular toothbrushing [Volpenhein et al., 1994]. The patients spent 32 s on toothbrushing posterior segments on average, which would correspond to about 8 s for each posterior segment [Volpenhein et al., 1994]. As an outside estimate, each tooth may be brushed for 8 s per day, considering the individual brushes each tooth for 4 s twice a day. Based on an estimated brushing stroke in the oral cavity of 2 strokes per second, 1 min of brushing would produce 120 strokes. Therefore, in order to mimic the home procedure, we used 120 strokes/min. In dental literature, previously reported number of strokes per minute were 60, 90, 120 [Schàtzk et al., 2009; Fujii et al., 2003; Da Costa et al., 2010]. The toothbrush selected for this study was a medium bristle toothbrush because it is the most recommended toothbrush by dentists [Da Costa et al., 2010].

Carvalho et al. [2008] evaluated the effect of different child tooth brushes on the surface roughness of conventional and resin-modified glass ionomer cements (RMGIC) in vitro. According to the results, manually mixed RMGIC showed the highest roughness values regardless of the type of tooth paste. This may be attributed to void formation when mixed manually. Thus, the type the restorative material per se is a determining factor on surface roughness values since the characteristics of filler particles, such as their composition, shape and size, as well as the entanglement of the resin and inorganic matrices, play an important role in the behaviour of restorative material. Sustaining research demonstrated that toothbrush abrasion of composite materials varied in accordance with the type of composite used [Kanter et al., 1982 ]. In the present study, only two composite materials (two microhybrid composites) were tested. Thus, further research is indicated to evaluate the effect of Tooth Mousse and Pronamel on different composite materials with various composition and particle sizes.

The type of dentifrice has also been reported as a factor related to composite wear [Goldstein and Turner, 1991; Wictorin, 1972]. The relative dentin abrasivity (RDA) of the toothpaste is a variable that influences the surface roughness of the restorative materials. An in

FIG. 5 SEM picture of TPH composite material under 200x magnification. TM: Tooth Mousse specimen, P: Pronamel specimen, C: Control.

art_207 12 Burcak.indd 138 07/05/13 11:42

Page 5: Effect of two anti-erosion pastes on surface roughness ...admin.ejpd.eu/download/EJPD_2013_02_10.pdf · tooth pastes on the baseline and final surface roughness of the restorative

ANTIEROSION PASTES AND SURFACE ROUGHNESS

EuropEan Journal of paEdiatric dEntistry vol. 14/2-2013 139

vitro in corsivo study showed that the higher the RDA of the toothpaste is, the higher are both the surface roughness and wear of dental materials [McCabe et al., 2002]. Tooth mousse is a water-based, sugar free “topical cream” containing casein phosphopeptide and amorphous calcium phosphate. Since it is not a “toothpaste” there is no data regarding its RDA. It contains 55% water, 20% gylicerol and 2% colloidal silica [GC Tooth Mousse Material Safety Data]. On the other hand, Pronamel is a derivative of Sensodyne toothpaste with high levels of bioavailable fluoride and has low RDA which is below 50% [Pronamel product information].

A recent review by Field et al. [2010] discussed about various surface quantifying and qualifying techniques and concluded that despite a variety of available in vitro tests for measuring surface changes, the roughness average (Ra) is still the main reported measurement within dental studies. However, the authors also proposed combination of the techniques. Thus, further research is indicated to assess the qualitative and quantitative changes on the restorative materials caused by Tooth Mousse and Pronenamel with different methods including qualitative evaluation.

During toothbrushing, the toothpaste is quickly diluted by saliva. In the present study, the pastes were not diluted prior to application according to the manufacturers’ directions. It could be argued that if a patient was brushing with these products, then this contact time with the restorative material would be reduced due to dilution of the pastes in oral cavity by saliva. Although this effect is simulated by diluting the toothpaste with water in in vitro studies; further special properties of saliva other than dilution, such as specific proteins and ions that may diminish the roughening effect, cannot be simulated [Heintze et al., 2010].

Since there is no previous data regarding the effects of these two pastes on the surfaces of restorative materials, no comparison could be made. Within the limitations of this in vitro preliminary study, the following conclusions were drawn.› When the initial and final surface roughness of the

tested materials are compared, neither Pronamel nor Tooth Mousse caused a significant change on the surface roughness of tested composites, compomer and Riva Self Cure. However, surface roughness of Ionofil U was significantly increased following brushing with either paste.

› Further laboratory research and in vivo studies are needed to understand the effects of Pronamel and Tooth Mousse on various tooth-colored restorations.

References

› Aker JR. New composite resins: Comparison of their resistance to toothbrush abrasion and characteristics of abraded surfaces. J Am

Dent Assoc 1982; 105:633-635.› Bartlett DW. The role of erosion in tooth wear: aetiology, prevention

and management. Int Dent J 2005;55:277-284.› Bollen CM, Lambrechts P, Quirynen M. Comparison of surface

roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater 1997;13:258-269.

› Carvalho FG, Fucio SB, Paula AB et al. Child toothbrush abrasion effect on ionomeric materials. J Dent Child (Chic) 2008;75:112-116.

› Catelan A, Briso AL, Sundfeld RH et al. Effect of artificial aging on the roughness and microhardness of sealed composites. J Esthet Restor Dent 2010;22:324-330.

› Da Costa J, Adams-Belusko A, Riley K et al. The effect of various dentifrices on surface roughness and gloss of resin composites. J Dent 2010;38:e123-128.

› Ehmford L. Surface microstructure of composite resins after toothbrushdentifrice abrasion. Acta Odontol Scand 1983;41:241-245.

› Field J, Waterhouse P, German M. Quantifying and qualifying surface changes on dental hard tissues in vitro. J Dent 2010;38:182-190.

› Fraleigh CM, Mc Elhaney JH, Heiser RA. Toothbrushing force study. J Dent Res 1967;46:209-214.

› Fujii K, Ban S, McCabe JF. Tooth brush abrasion of paint-on resins for shade modification of crown and bridge resins. Dent Mater J 2003;22: 244-250.

› Garcia-Godoy F, Garcia-Godoy A, Garcia-Godoy C. Effect of a desensitizing paste containing 8% arginine and calcium carbonate on the surface roughness of dental materials and human dental enamel. Am J Dent 2009;22: 21A-24A

› GC Tooth Mousse Material Safety Data Sheet acc. to ISO/DIS 11014, printed in 2007.

› Goldstein GR, Turner T. The effect of tooth brushing on a hybrid composite resin. J Prosthet Dent 1991;66:498-500.

› Heintze SD, Forjanic M, Ohmiti K et al. Surface deterioration of dental materials after simulated toothbrushing in relation to brushing time and load. Dent Mater 2010;26:306-19.

› Kanter J, Koski RE, Martin D. The relationship of weight loss to surface roughness of composite resins from simulated toothbrushing. J Prosthet Dent 1982;47:505-513.

› Marsh Pd, Nyvad B. The oral microflora and biofilm on teeth. In: Fejerskov O, Kidd EAM. Dental Caries: the disease and Its clinical management. Oxford: Blackwell Munksgaard, 2003: pp.29-48.

› McCabe JF, Molyvda S, Rolland SL et al. Two and three-body wear of dental restorative materials. Int Dent J 2002;52:406–416.

› Neme AL, Frazier KB, Roeder LB et al. Effect of prophylactic polishing protocols on the surface roughness of esthetic restorative materials. Oper Dent 2002;27:50–58.

› Pronamel product information, www.dental-professional.com› Quirynen M, Bollen CM, Papaioannou W et al. The influence of

titanium abutment surface roughness on plaque accumulation and gingivitis: short-term observations. Int J Oral Maxillofac Implants 1996;11:169-178.

› Rees J, Loyn T, Chadwick B. Pronamel and tooth mousse: an initial assessment of erosion prevention in vitro. J Dent 2007;35:355-357.

› Schätzle M, Imfeld T, Sener B et al. In vitro tooth cleaning efficacy of manual toothbrushes around brackets. Eur J Orthod 2009;31:103-107

› Tanoue N, Matsumura H, Atsuta M. Wear and surface roughness of current prosthetic composites after toothbrush/dentifrice abrasion. J Prosthet Dent 2000;84:93–97.

› Voltarelli FR, Santos-Daroz CB, Alves MC et al. Effect of chemical degradation followed by toothbrushing on the surface roughness of restorative composites. J Appl Oral Sci 2010;18:585-590

› Wictorin L. Effect of toothbrushing on acrylic resin veneering material. II.Abrasive effect of selected dentrifrices and toothbrushes. Acta Odontol Scand 1972;30:383-395.

art_207 12 Burcak.indd 139 07/05/13 11:42