24
Photoelectronic Sensors for Roller Conveyor Systems OPT104 Part Number These sensors have been specially designed for use in accumulation roller conveyors. Their compact design allows for installation between rollers below the trans- port level. They are thus protected against mechanical damage. Reflex Sensor Technical Data Range 550 mm Potentiometer min 220...270 mm Potentiometer center 320...400 mm Potentiometer max 550...630 mm Switching Hysteresis < 15 % Light Source Infrared Light Wave Length 880 nm Service Life (T = +25 °C) 100000 h Risk Group (EN 62471) 1 Max. Ambient Light 10000 Lux Opening Angle 5 ° Optical Data Supply Voltage 18...30 V DC Current Consumption Sensor (Ub = 24 V) < 30 mA Switching Frequency 100 Hz Response Time 5 ms Temperature Drift < 10 % Temperature Range -15...50 °C Switching Outputs 1 Switching Output Voltage Drop < 0,8 V PNP Switching Output/Switching Current 200 mA Short Circuit Protection yes Reverse Polarity Protection yes Overload Protection yes Logic yes Single Discharge yes Block Discharge yes Pneumatic Solenoid Valve Unit yes Protection Class III Electrical Data Adjustment Potentiometer Housing Material Plastic Full Encapsulation yes Degree of Protection IP65 Connection M12 × 1; 4-pin Cable Length 88 cm Mechanical Data K04 Valve no. 19,2...28,8 V Supply Voltage Valve 86 mA Current Consumption Valve 4...7 bar Operating Pressure 0,8 mm Nominal Width 20 NL/min Nominal flow rate 1 -> 2 100 NL/min Nominal flow rate 2 -> 3 2× 8×1 Supply line connector pipe 4×1 Working line connector pipe 3/2-Way Valve function NC Switching function Pneumatic Solenoid Valve Unit PNP NC Connection Diagram No. 714 Control Panel No. OP1 Suitable Connection Technology No. 2 2s Suitable Mounting Technology No. 420 Electronic background suppression Fully encapsulated Integrated logic Scaled switching distance adjuster

for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

  • Upload
    others

  • View
    6

  • Download
    1

Embed Size (px)

Citation preview

Page 1: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT104Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -15...50 °CSwitching Outputs 1Switching Output Voltage Drop < 0,8 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic yesSingle Discharge yesBlock Discharge yesPneumatic Solenoid Valve Unit yesProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pinCable Length 88 cm

Mechanical Data

K04Valve no.19,2...28,8 VSupply Voltage Valve86 mACurrent Consumption Valve4...7 barOperating Pressure0,8 mmNominal Width20 NL/minNominal flow rate 1 -> 2100 NL/minNominal flow rate 2 -> 32× 8×1Supply line connector pipe4×1Working line connector pipe3/2-WayValve functionNCSwitching function

Pneumatic Solenoid Valve Unit

PNP NC

Connection Diagram No. 714Control Panel No. OP1Suitable Connection Technology No. 2 2sSuitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedIntegrated logicScaled switching distance adjuster

Page 2: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Complementary ProductsAdapter OPT70N, 70S, 70S+

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

714 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 3: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT123Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 1Switching Output Voltage Drop < 1,5 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pin

Mechanical Data

PNP NO

Connection Diagram No. 712Control Panel No. OP1Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedScaled switching distance adjuster

Page 4: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

4

3

A

2nc

712 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 5: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT144Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 1Switching Output Voltage Drop < 0,8 VPNP Switching Output/Switching Current 200 mAValve or Motor Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic yesSingle Discharge yesBlock Discharge yesOutput Magnetic Valve/Engine yesProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pinCable Length 88 cm

Mechanical Data

PNP NC

Connection Diagram No. 715Control Panel No. OP1Suitable Connection Technology No. 2 2sSuitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedIntegrated logicScaled switching distance adjuster

Page 6: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Complementary ProductsAdapter OPT70N, 70S, 70S+

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

3

1

4

3

3

4

2

1

AMV

BZ

A

4

5

3

4

2

1

BZ

E

715

2nc

Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 7: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT164Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Retro-Reflex Sensor

Technical Data

Range 6500 mmReference Reflector/Reflex Foil RQ100BAMin. Distance to Reflector 100 mmSwitching Hysteresis < 15 %Light Source Red LightPolarization Filter yesService Life (T = +25 °C) 100000 hMax. Ambient Light 10000 LuxOpening Angle 5 °Two-Lens Optic yes

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 25 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 1Switching Output Voltage Drop < 0,8 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP54Connection M12 × 1; 4-pin

Mechanical Data

PNP NO

Connection Diagram No. 738Control Panel No. OP2Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Fully encapsulatedLarge working rangeRecognition of high-gloss and jet black objects

Page 8: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

01

OP2

Ctrl. Panel

01 = Switching Status Indicator

Complementary ProductsReflector, Reflex Foil Feasible reflector distance

Reflector type, mounting distance

RQ100BA 0,25...6,5 mRE18040BA 0,1...4 mRQ84BA 0,25...5 mRR84BA 0,2...5 mRE9538BA 0,15...2 mRR50_A 0,15...3 mRE6040BR 0,2...2,5 mRE8222BA 0,25...1,8 m

ZRAE02B01 0,2...1,8 mZRME03B01 0,15...2 mRF505 0,15...1,9 mRF508 0,15...1,9 mRF258 0,15...1,5 mZRDF03K01 0,1...3,5 mZRDF10K01 0,1...4,5 m

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

2

3

A

4nc

738 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 9: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT229Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 760 mmPotentiometer min 250...300 mmPotentiometer center 400...550 mmPotentiometer max 760...900 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 1Switching Output Voltage Drop < 1,5 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pin

Mechanical Data

PNP NC

Connection Diagram No. 711Control Panel No. OP1Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedScaled switching distance adjuster

Page 10: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

2

3

A

711

4nc

Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 11: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT231Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 760 mmPotentiometer min 250...300 mmPotentiometer center 400...550 mmPotentiometer max 760...900 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 1Switching Output Voltage Drop < 1,5 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pin

Mechanical Data

PNP NO

Connection Diagram No. 712Control Panel No. OP1Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedScaled switching distance adjuster

Page 12: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

4

3

A

2nc

712 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 13: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT244-P06Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msOff-Delay 0...2 sTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 2Switching Output Voltage Drop < 0,8 VPNP Switching Output/Switching Current 200 mAValve or Motor Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic yesSingle Discharge yesOutput Magnetic Valve/Engine yesAutomatic roll cutoff yesProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pinCable Length 150 cm

Mechanical Data

PNP NC

Connection Diagram No. 733Control Panel No. OP1Suitable Connection Technology No. 2 2sSuitable Mounting Technology No. 420

Electronic background suppressionEnergy-saving trough automatic roll cutoffFully encapsulatedIntegrated logicScaled switching distance adjuster

Page 14: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Complementary ProductsAdapter OPT70N, 70S, 70S+

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

3

4AMV

3

1

3

2

4A

E

4

5

1

3

2

4E

A

2nc

733 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 15: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT246Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 2Switching Output Voltage Drop < 1,5 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pin

Mechanical Data

PNP NO/NC antivalent

Connection Diagram No. 754Control Panel No. OP1Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedScaled switching distance adjuster

Page 16: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

754 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 17: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT255Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -15...50 °CSwitching Outputs 1Switching Output Voltage Drop < 0,8 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic yesSingle Discharge yesBlock Discharge yesPneumatic Solenoid Valve Unit yesProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pinCable Length 100 cm

Mechanical Data

K04Valve no.19,2...28,8 VSupply Voltage Valve86 mACurrent Consumption Valve4...7 barOperating Pressure0,8 mmNominal Width20 NL/minNominal flow rate 1 -> 2100 NL/minNominal flow rate 2 -> 32× 8×1Supply line connector pipe4×1Working line connector pipe3/2-WayValve functionNCSwitching function

Pneumatic Solenoid Valve Unit

PNP NC

Connection Diagram No. 734Control Panel No. OP1Suitable Connection Technology No. 2 2sSuitable Mounting Technology No. 420

Electronic background suppressionIntegrated logicOPT255: block discharge can be executed withsignal level 24V (I>1mA)Scaled switching distance adjuster

Page 18: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Complementary ProductsAdapter OPT70N, 70S, 70S+

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

734 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 19: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT285Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 760 mmPotentiometer min 250...300 mmPotentiometer center 400...550 mmPotentiometer max 760...900 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 2Switching Output Voltage Drop < 1,5 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pin

Mechanical Data

PNP NO/NC antivalent

Connection Diagram No. 754Control Panel No. OP1Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedScaled switching distance adjuster

Page 20: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

754 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 21: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT307Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 760 mmPotentiometer min 250...300 mmPotentiometer center 400...550 mmPotentiometer max 760...900 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -15...50 °CSwitching Outputs 1Switching Output Voltage Drop < 0,8 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic yesSingle Discharge yesBlock Discharge yesPneumatic Solenoid Valve Unit yesProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pinCable Length 88 cm

Mechanical Data

K04Valve no.19,2...28,8 VSupply Voltage Valve86 mACurrent Consumption Valve4...7 barOperating Pressure0,8 mmNominal Width20 NL/minNominal flow rate 1 -> 2100 NL/minNominal flow rate 2 -> 32× 8×1Supply line connector pipe4×1Working line connector pipe3/2-WayValve functionNCSwitching function

Pneumatic Solenoid Valve Unit

PNP NC

Connection Diagram No. 714Control Panel No. OP1Suitable Connection Technology No. 2 2sSuitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedIntegrated logicScaled switching distance adjuster

Page 22: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Complementary ProductsAdapter OPT70N, 70S, 70S+

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

714 Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice

Page 23: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

Photoelectronic Sensors

for Roller Conveyor Systems

OPT89Part Number

These sensors have been specially designed for use inaccumulation roller conveyors. Their compact designallows for installation between rollers below the trans-port level. They are thus protected against mechanicaldamage.

Reflex Sensor

Technical Data

Range 550 mmPotentiometer min 220...270 mmPotentiometer center 320...400 mmPotentiometer max 550...630 mmSwitching Hysteresis < 15 %Light Source Infrared LightWave Length 880 nmService Life (T = +25 °C) 100000 hRisk Group (EN 62471) 1Max. Ambient Light 10000 LuxOpening Angle 5 °

Optical Data

Supply Voltage 18...30 V DCCurrent Consumption Sensor (Ub = 24 V) < 30 mASwitching Frequency 100 HzResponse Time 5 msTemperature Drift < 10 %Temperature Range -25...60 °CSwitching Outputs 1Switching Output Voltage Drop < 1,5 VPNP Switching Output/Switching Current 200 mAShort Circuit Protection yesReverse Polarity Protection yesOverload Protection yesLogic noProtection Class III

Electrical Data

Adjustment PotentiometerHousing Material PlasticFull Encapsulation yesDegree of Protection IP65Connection M12 × 1; 4-pin

Mechanical Data

PNP NC

Connection Diagram No. 711Control Panel No. OP1Suitable Connection Technology No. 2Suitable Mounting Technology No. 420

Electronic background suppressionFully encapsulatedScaled switching distance adjuster

Page 24: for Roller Conveyor Systems OPT104 · 2015-01-12 · for Roller Conveyor Systems OPT164 Part Number These sensors have been specially designed for use in accumulation roller conveyors

30

05

OP1

Ctrl. Panel

05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning

Switching Distance DeviationTypical characteristic curve based on Kodak white (90 % remission)

OPT

200 250 300 350 400 450 500 550 600

-70

-60

-50

-40

-30

-20

-10

0

10

Sr/mm

dS

r/m

m

Pot. = Potentiometer Setting

dSr = Switching Distance Change

black 6 % remission

grey 18 % remission

All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode2 = Receiver Diode

1

2

3

A

711

4nc

Legend

Wire Colors according to DIN IEC 757

not connected

Test Input

Test Input inverted

Trigger Input

Analog Output

Ground for the Analog Output

Block Discharge

Valve Output

Valve Control Output +

Valve Control Output 0 V

Synchronization

Receiver-Line

Emitter-Line

Grounding

Switching Distance Reduction

Ethernet Receive Path

Ethernet Send Path

Interfaces-Bus A(+)/B(–)

Emitted Light disengageable

Magnet activation

Input confirmation

Contactor Monitoring

Black

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Pink

Green Yellow

Supply Voltage +

Supply Voltage 0 V

Supply Voltage (AC Voltage)

Switching Output (NO)

Switching Output (NC)

Contamination/Error Output (NO)

Contamination/Error Output (NC)

Input (analog or digital)

Teach Input

Time Delay (activation)

Shielding

Interface Receive Path

Interface Send Path

Ready

Ground

Clock

Output/Input programmable

Power over Ethernet

Safety Input

Safety OutputSignal Output

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice